Electric Mortice Locks AAA-CAT-069 0609 MS0458 AAA-CAT-069

StrikesContents

3570 Series Electric Mortice Lock 2 3570/3670 Series Proximity Mortice Lock & Furniture 8 3570 Series Room Guard Electric Mortice Locks & Controller 12 3580 Series Electric Mortice Lock 14 EL402 Solenoid Lock 20 EL502 Solenoid Lock 22 EL580 Solenoid Lock 24 EL648 Motor lock 26 Power Transfer Cover 28

1 3570 Series Electric Mortice Lock

General Information Designed and manufactured in Australia, the 3570 series electric mortice is a high performance lock of superior quality. It is constructed from high grade zinc alloy, with a stainless steel latch bolt and face plate and is suited for all commercial applications.

The lock can be operated by push buttons, intercom systems and key switches; or integrated with electronic systems for use with higher security devices such as keypads or card readers.

Key Features Designed with flexibility in mind, the one lock can cover all functions and is easily configured on site for the required application.

Available in non monitored and monitored versions.

Monitoring features: • Dead latched and Locked • position/Reed switch • Dual key override monitoring • Request to exit/REX • LED indication

Field Changeable settings: • Fail /fail secure configuration. •Multi-voltage - will work on 12-24 Vdc systems. • Handing - left hand and right hand Standards and Compliance • Selection of free lever or locked lever on both sides of the door S3 (Security) Australian Lock Standard (AS4145.2.1993) • Key override monitoring either side of the door (when used with equivalent security level keying system) D3 (Durability) Australian Lock Standard (AS4145.2.1993) • Monitoring contacts – normally closed, Successfully fire rated up to 4hrs on fire door assemblies normally open (for key override and request 4 Hour in accordance with AS1905.1. 2005 to exit only) (Part 1: Fire resistant door sets)

C-Tick Certified

3570 Series: SCEC endorsed for intruder resistant areas

3579 Series: SCEC endorsed for secure areas

2 assaabloy.com.au 3570 Series Electric Mortice Lock

A 37

26 14

A 37 124 28.5 26 64 14 175 24 57 68 39

68 39 18 30 Reed Magnet

124 28.5 64 175 4 B 25

57 15 70

54 1.5 30 15 19 70 28.5 4 B 25 46 54 1.5 18 32 15 Note: width of case increases 28.5 from 19mm to 23 mm for 38 15 46 19 3579 series32 SCEC lock

Dimension Backset 38 A 60 18 89 127

B 100 129 167

Specification Statement 3570 Technical Information The lock should be capable of operation on voltages Voltage 12Vdc - 24Vdc Operating Voltage between 12 – 24Vdc and have a current consumption

Current 500mA (max) 80mA holding @ 12Vdc not more than 80mA (holding) @12Vdc and 50mA 275mA (max) 50mA holding @ 24Vdc (holding) @24Vdc. Monitored locks must be capable of monitoring the following functions: Key override, LED Current When LED’s are fitted, add 15mA (max) to total current draw door position / reed switch, selectable hub / Request to Monitoring Dual Key override Deadlatched exit, & locking bar status. All monitoring outputs must Locked have the ability to be wired independently. All settings Door closed – including: fail safe / fail secure, handing, hub selection Request to exit Microswitches: 500mA (max) @ 30Vdc each circuit. must be field configurable. Reedswitch: 100mA (max) @ 30Vdc Environment Operational temperature range -20c to + 60c

Case/ Cover High purity Zinc alloy construction

Backset 60mm standard, 89 & 127 mm available

Latch bolts Reversible with Stainless Steel construction.

Door Clearance 3 – 6.5 mm

Door thickness Standard applications 32 to 50mm.

Cylinder Standard Lockwood oval shaped cylinders.

Cabling 1.6 metre length of cable with 12 pin socket supplied with each lock. Recommended cable: 18AWG (0.82mm²) cable runs up to 30m.

Furniture Compatible with Lockwood series door furniture. Standard Finishes Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available

Note: For detailed electrical specifications, turn to page 7.

3 3570 Series Electric Mortice Lock

Ordering Procedure Sample Part Number 3572ELAM2RSC is made up of several sections. Choose your product by selecting an option from each section.

For example:

Backset Fixing Lock Electric Safety Sub Handing Finish Functions Lock Function Function 3 5 72 EL A M2 R SC

Backset Lock Functions Safety Function Right Handing

60 mm 3 Primary lock 70 Fail Safe A Right Handing R (Power to lock) 89 mm 4 Vestibule lock 72 Left Handing L Fail Secure E 127 mm 5 74 (Power to unlock) Secure Area Rated Lock 79

Fixing Sub Function Finish

Electric Lock Standard 5 Non-monitored lock Satin Chrome SC Securafix® 6 Electric Lock EL (0 Cylinders) N0 Chrome Plate CP Non-monitored lock Polished Brass PB (1 Cylinders) N1 Non-monitored lock (2 Cylinders) N2 Fully monitored lock including KOM (0 Cylinders) M0 Fully monitored lock including KOM (1 Cylinder) M1 Fully monitored lock including KOM (2 cylinders) M2

KOM- (Key overrride moitoring) Ordering Notes Backset Nominate backset as required, eg 60mm 3 • 3570 Primary Locks can be set to achieve all

Fixing lock functions post purchase, and should be Select the desired fixing method, eg Standard Fixing 35 35 the preferred option when ordering.

Lock Function • Customised locks are available upon request Select function, eg Vestibule Lock 3572 and incur an additional surcharge and 10 day Electrical Variant lead time. Indicate that this is an Electric Lock 3582EL

Safety Function • Securafix locks are available in 60mm backset Select whether lock should be Fail Secure or Fail Safe, eg Fail Safe 3572ELA only and are made to order. 10 day lead time.

Monitoring and Key Override Options • See over page for Primary Lock part numbers. Select monitoring and cylinders to be supplied, 3572ELAM2 eg Monitored Lock with two cylinders Handing Chart Handing Determine left or right handing, eg Right Handed 3572ELAM2R DOOR OPENING IN Finish RIGHT LEFT Specify appropriate finish, eg Satin Chrome 3572ELAM2RSC HAND INSIDE HAND

OUTSIDE

DOOR OPENING OUT

INSIDE

RIGHT OUTSIDE LEFT HAND HAND

4 assaabloy.com.au 3570 Series Electric Mortice Lock

Ordering Notes • Primary locks can be set post purchase to achieve all desired lock settings e.g. fail safe or fail secure, left hand or right hand, combination lock (locked both sides) or vestibule lock (locked outside & free lever inside)

• All locks are Multi-voltage 12-24Vdc

• 3570 Primary locks (std 60mm backset) are stocked items. All other items are made to order, 10 day lead time. Primary Electric Mortice Lock Ordering Procedure

Description - Non-Monitored Cylinders Part No

Electric Mortice Lock 3570 Primary Lock 60 mm Backset Non Monitored No Cylinder 3570eln0sc Electric Mortice Lock 3570 Primary Lock 60 mm Backset Non Monitored 1 Cylinder 3570eln1sc Electric Mortice Lock 3570 Primary Lock 60 mm Backset Non Monitored 2 Cylinder 3570eln2sc

Electric Mortice Lock 4570 Primary Lock 89mm Backset Non Monitored No Cylinder 4570eln0sc Electric Mortice Lock 4570 Primary Lock 89 mm Backset Non Monitored 1 Cylinder 4570eln1sc Electric Mortice Lock 4570 Primary Lock 89 mm Backset Non Monitored 2 Cylinder 4570eln2sc

Electric Mortice Lock 5570 Primary Lock 127 mm Backset Non Monitored No Cylinder 5570eln0sc Electric Mortice Lock 5570 Primary Lock 127 mm Backset Non Monitored 1 Cylinder 5570eln1sc Electric Mortice Lock 5570 Primary Lock 127 mm Backset Non Monitored 2 Cylinder 5570eln2sc

Description - Monitored Cylinders Part No (hub, deadlatch, solenoid, door position, key override monitoring all as standard)

Electric Mortice Lock 3570 Primary Lock 60 mm Backset Monitored No Cylinder 3570ELM0SC Electric Mortice Lock 3570 Primary Lock 60 mm Backset Monitored 1 Cylinder 3570ELM1SC Electric Mortice Lock 3570 Primary Lock 60 mm Backset Monitored 2 Cylinder 3570ELM2SC

Electric Mortice Lock 4570 Primary Lock 89 mm Backset Monitored No Cylinder 4570ELM0SC Electric Mortice Lock 4570 Primary Lock 89 mm Backset Monitored 1 Cylinder 4570ELM1SC Electric Mortice Lock 4570 Primary Lock 89 mm Backset Monitored 2 Cylinder 4570ELM2SC

Electric Mortice Lock 5570 Primary Lock 127 mm Backset Monitored No Cylinder 5570ELM0SC Electric Mortice Lock 5570 Primary Lock 127 mm Backset Monitored 1 Cylinder 5570ELM1SC Electric Mortice Lock 5570 Primary Lock 127 mm Backset Monitored 2 Cylinder 5570ELM2SC

5 3570 Series Electric Mortice Lock

14

4 12.7 Accessories - Rebate Kits 29

26.5 1.5 Finish “A” Part Number

Bright Chrome 32 3570-2905BC 46 3570-3905BC Polished Brass 32 3570-2905PB 46 3570-3905PB 177 184 51 75 Satin Stainless Steel 32 3570-2905SC 46 3570-3905SC

A

Accessories - Long Lipped Strikes 1.5 Finish “A” Part Number 46 Bright Chrome 43.5 3570-5353CP 47.5 3570-5653CP 28.5 Polished Brass 43.5 3570-5353PB 47.5 3570-5653PB 70 54 38 Satin Stainless Steel 43.5 3570-5253SSS Long Lipped Strike 47.5 3570-5453SSS

A

Accessories Ordering Information

Product Description Part Number Extended Cylinders Extended cylinders should be considered when LED assembly to suit 3570/3580 SP572-3129 door thickness exceeds 50 mm or when the (suits furniture for monitored locks) lock is mounted off centre in the door edge. 7.5m extended 12 wire cable SP3570-1055 A range of cylinders is available to suit various 9/12 wire adaptor to suit 3570 series electric lock SP3570-5861 door thicknesses. Refer to ASSA ABLOY Australia 323mm Power Transfer Cable LC8810 Keying and Restricted Price List for further 543mm Power Transfer Cable LC8811 information.

A Extended Cylinders

“A” Cylinder Cylinder Recommended Door Projection Length Thickness

41 37 50 to 60 52 48 60 to 84 64 60 84 to 108 80 76 108 to 132  88 84 132 to 156

6 assaabloy.com.au 3570 Series Electric Mortice Lock

Electrical Specifications 12 Pin Circuit Diagram Connector Note: Diagram depicts fail safe RH opened door, with handle and key in rest state.

DIL Switch Settings Hub Monitor Switch Number Lock Normal 1 2 3 4 Side Function ON OFF AN / C

ON OFF AN / O

ON OFF BN / C Deadlatched and locked centre tap (White) ON OFF BN / O

Key Override Monitor Selection

SIDE B Key Key Override Override N/O Monitor Selection Monitor Selection N/C Set the 2 way switch K.O.M SWITCH to desired setting SELECTION

Hub Monitor Selecion

Solenoid Activation Colour Function Operating Voltage: Black Solenoid (0Vdc) 12 - 24Vdc Red Solenoid Positive (12Vdc - 30Vdc) Operating Current: Green LED (12Vdc - 30Vdc) 500mA (max) 80mA holding @ 12Vdc Yellow Door closed Reedswitch (NC) 275mA (max) 50mA holding @ 24Vdc Pink Door closed Reedswitch (common) Light Blue Deadlatched and Locked (NC) For confirmation of the above mentioned Grey Deadlatched and Locked (common) operating current, please see installation manual. White Deadlatched and Locked centre tap LED Current Brown Hub monitor (NO or NC) Where LEDs are fitted, add 20mA (max) to total Blue Hub monitor (common) operating current. Orange Key override monitor (NO or NC) Violet Key override monitor (common) Monitoring Circuits

Microswitches: 500mA (max) @ 30Vdc each circuit Reedswitch: 100mA (max) @ 30Vdc

7 3570/3670 Series Proximity Mortice Lock & Furniture

General Information When security, safety, functionality and stylish design are a priority, there’s only one solution – Lockwood Proximity Furniture!

Incorporating proximity technology within its sleek external door plate, the reader connects directly to a Lockwood electric mortice lock.

Easy to install and operate, Lockwood Proximity Furniture is available in a wide range of stylish levers and finishes to enhance any contemporary building design, bringing a new dimension to commercial security locking solutions.

One Install – One Connect. Comprising the Lockwood Electric Mortice Lock, HID Proximity Reader and Door Furniture.

Proximity Furniture™ is available in standard “through fix” and Securafix specifications.

Key Features • Integrated proximity reader -125 Khz HID Prox • One install one connect • Fully monitored

Monitoring features: • Dead latched and locked

• Door position/reed switch

• Dual key override

• Request to exit/REX

Field Changeable settings: • Fail safe/fail secure configuration. Standards and Compliance • Multi-voltage - will work on 12-24 Vdc S3 (Security) Australian Lock Standard (AS4145.2.1993) systems. (when used with equivalent security level keying system) D3 (Durability) Australian Lock Standard (AS4145.2.1993) • Handing - left hand and right hand doors Successfully fire rated up to 4hrs on fire door assemblies 4 • Selection of free lever or locked lever on both Hour in accordance with AS1905.1. 2005 sides of the door (Part 1: Fire resistant door sets) C-Tick Certified • LED indication

• Monitoring contacts – normally closed, normally open (for key override and request to exit only)

8 assaabloy.com.au A 37

3570/3670 Series Proximity

124 Mortice Lock & Furniture 28.5 64 175

57

30

4 B 25

A A 37 37 15 26 26 14 14 24 15 19

18 68 68 39 39 18 28.5 124 124 28.5 64 64 175 175 Reed Magnet

57 57

30 30 26 14 70 70 4 B 25 4 B 25 54 54 1.5 1.5

15 15 68 39 28.528.5 46 46 32 32 15 15 19 19

38 38

18 18 3570/3670 Technical Information Specification Statement 70 HID Reader HID 125KHz Proximity Reader The lock and door furniture should encompass Data Output: Weigand an54 integrated proximity1.5 reader, capable of Supply voltage: 5-12Vdc LED: visual indication of reader / lock status reading HID 125khz proximity technology with 28.5 card formats up46 to 85bits. Operational voltage Lock Voltage 12Vdc - 24Vdc 32 should be between 12-24Vdc. The lock must be Current 500mA (max) 80mA holding @12Vdc capable of monitoring the following functions: 275mA (max) 50mA holding @24Vdc 38 Key override, door position / reed switch, Indicator LED signalling door status independent hub / Request to exit, & locking Monitoring Dual Key override bar status. All settings – including: fail safe / fail Deadlatched secure, handing, hub selection must be field Locked Door closed configurable. Request to exit Microswitches: 500mA (max) @ 30Vdc each circuit. Reedswitch: 100mA (max) @ 30Vdc

Environment Operational temperature range -20°C to + 60°C

Case/ Cover Furniture: Solid Brass construction Lock: High purity zinc alloy construction

Backset Lock available in 60mm backset only

Latch bolts Reversible 15mm Stainless Steel construction.

Door Clearance 3 – 6.5mm

Door thickness Standard applications 32 to 45mm standard.

Cylinder Standard Lockwood oval shaped cylinders.

Cabling 1.6 metre length of cable with 12 pin socket Recommended cabling: 18AWG (0.82mm²) cable runs up to 30m

Mortice Lock Compatible with Lockwood 3572PL and 3672PL electric mortice lock

Standard Finishes Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available

Note: For detailed electrical specifications, turn to page 11.

9 3570/3670 Series Proximity Mortice Lock & Furniture

Ordering Procedure Ordering Notes Sample Part Number 3570PLM0SC is made up of several sections. • All 3570 & 3670 series proximity locks are Choose your product by selecting an option from each section. non handed and can be set to required settings post purchase For example:

Backset Fixing Lock Proximity Monitoring Finish Accessories Ordering Information Functions Lock 3 5 70 PL M0 SC Product Description Part Number

Backset Lock Functions Monitoring 12 Wire cable extension 7.5m length 3570-1055

60 mm 3 Primary Lock 70 Monitored Lock including 125 Khz HID reader assembly for prox furniture prox1-125khz KOM (0 cylinders) M0 Fixing Proximity Lock Monitored Lock including KOM (1 cylinders) M1 Standard 5 Proximity Lock PL ® Securafix 6 Finishes

Satin Chrome SC Bright Chrome CP Polished Brass PB

Proximity Furniture Ordering Procedure Sample Part Number 1878SF70RCP55 is made up of several sections. Choose your product by selecting an option from each section.

For example:

Plate Type Plate Fixing Lever/ Handing Finishes Door Function Knob Thickness 18 78 SF 70 R CP 55

Plate Type Fixing Handing Door Thickness

Exterior Square End 18 Standard (no suffix) Right handed R 32-45mm (no suffix) Exterior Round End 28 Securafix SF Left Handed L 45-55mm 55 55-65mm 65 Lever/Knob Plate Function Finishes 65-75mm 75 Exterior plate with HID 125 Specify lever or knob. Subject Chrome Plate CP to existing tier structure kHz Proximity Reader 78 Polished Brass PB Tier 1 Internal Plain plate & lever 05 Satin Chrome SC 00, 20, 32, 39, 40, 60, 70, 71, 78, 80, 83, 87, 90, 97. Tier 2 41, 43, 44, 45, 48, 50, 53, 54, 57, 59, 61, 69, 72, 73, 74.

DOOR OPENING IN Securafix®Ordering Notes: RIGHT LEFT • One internal plate and one external plate is required HAND INSIDE HAND for each lock. OUTSIDE

• For each set of furniture plates, one must be handed DOOR OPENING OUT

R and one handed L. Furniture plates are ordered INSIDE

separately to the Lock. RIGHT OUTSIDE LEFT HAND HAND • The handing of Securafix plates cannot be changed.

10 assaabloy.com.au 3570/3670 Series Proximity Mortice Lock & Furniture

Pin Colour Function 1 Black Common 0Vdc 2 Red Soleniod Positive

3 L. Blue Deadlatch Monitor N/C Plug To Power Housing Supply 4 Blue Door Monitor Reed N/C 5 Grey Hub Monitor N/O or N/C 6 Violet Key Override Monitor N/O or N/C 7 Brown Monitor Common Receptacle 8 Pink Reader Power 5-12Vdc Housing 9 Orange Green LED From 10 Yellow Reader 0Vdc Electric Lock 11 Green Weigand Data 0 12 White Weigand Data 1

11 3570 Series Room Guard Electric Mortice Locks & Controller

The Room Guard Privacy controller system provides electronic lock control of multiple doors for any room requiring privacy by the occupants. The most common applications are INSIDE ROOM shared ensuites in hospitals and conference rooms with two or more entry doors.

The system allows all doors to be locked and Room Guard unlocked from any door in the system. Each lock 12Vdc regulated Privacy provides a clear visual indication, both inside power supply Controller and outside, which displays the locked/unlocked status of the door at a glance. Emergency Features override switches (outside room) • Uses standard 3570EL series mortice lock

• Non handed – all settings are field configurable

• One touch privacy

• Clear visual indication - LED furniture

• Unique integrated turn knobs LED Turn Knob Power • Emergency override Transfer Device Applications • Shared ensuites/toilets

• Darkroom studios

• Conference rooms 3570 EL Electric Power Mortice Lock • Laboratories Transfer Device • Any area for which “one touch” privacy locking is required

Function In the dormant state, all locks are unlocked and Standards and Compliance the LED on the external furniture plate indicates green. S3 (Security) Australian Lock Standard (AS4145.2.1993) To lock the lock (when used with equivalent security level keying system) 1. Close all doors D3 (Durability) Australian Lock Standard (AS4145.2.1993) Successfully fire rated up to 4hrs on fire door assemblies 4 2. Activate one of the turn knobs located on the Hour in accordance with AS1905.1. 2005 inside of the door (Part 1: Fire resistant door sets)

3. Simultaneously the lever handles on the C-Tick Certified outside of each door will lock and the LED furniture indication will change to red. (inside lever will remain free at all times)

To Unlock the Room 1. Operate the inside lever of either lock.

2. Simultaneously the locks will unlock and the LED furniture indication will return to green.

12 assaabloy.com.au 3570 Series Room Guard Electric Mortice Lock & Controller

Standard Two Room Guard Door Connection Privacy Controller

Pink 3570 EL Electric 3570 EL Electric Pink

3570 Series Room Guard Technical Information Specification Statement Locking control of the room must be via a Voltage 12Vdc - 24Vdc standalone door controller independent of Current 500mA (max) 80mA holding @ 12Vdc the building electronic access control system. 275mA (max) 50mA holding @ 24Vdc The controller shall be capable of providing LED Current When LED’s are fitted, add 15mA (max) to simultaneous locking/unlocking of up to total current draw 4 locks via internal integrated turn knobs. Monitoring Microswitches: 500mA (max) @ 30Vdc each Emergency egress or unlocking to be achieved circuit. Reedswitch: 100mA (max) @ 30Vdc via single downward action of internal lever Environment Operational temperature range -20c to + 60c or externally mounted override switch. The

Case/Cover High purity Zinc alloy construction locks should be capable of operation on voltages between 12 – 24Vdc. All lock settings Backset 60mm standard, 89 & 127 mm available – including: fail safe/fail secure, handing, hub Latch bolts Reversible with Stainless Steel construction selection must be field configurable. Door Clearance 3 – 6.5 mm

Door thickness Standard applications 32 to 50mm Ordering Information Note: Due to Cylinder Standard Lockwood oval shaped cylinders Product Description Part Number the variety of Cabling 1.6 metre length of cable with 12 pin socket installation décor, Lockwood does not supplied with each lock Room Guard Privacy Controller plus regulated power Recommended cable: 18AWG (0.82mm²) supply emergency supply (12Vdc, 1.5AMP). RG2PS release push Furniture Compatible with Lockwood series door Room Guard Privacy Controller. RG2 buttons. However furniture we recommend a Turn knobs, designed for the integrated Clipsal model 31 Standard Finishes Satin Chrome(SC) standard. Bright Chrome assembly with Lockwood electric mortice locks. architrave mounting (CP) and Polished Brass(PB) finishes available Other finishes available upon application. RG3SC plate with model 30MBP push button, or equivalent, Note: For detailed electrical specifications, turn to page 7. A typical room with two doors requires the following equipment: available from 1 x Room Guard Privacy Controller RG2PS or RG2 most electrical wholesalers. Accessories Ordering Information 2 x Room Guard Privacy Controller turn knobs RG3SC 2 x Electric Mortice Locks 3570ELM0SC Product Description Part Number 2 x Power transfer devices LC8810

7.5m extended 12 wire cable SP3570-1055 2 x Exterior door furniture 1822/70SC

9/12 Wire adapter to suit 3570 series electric lock SP3570-5861 2 x Interior door furniture 1920/70SC

2 x 7.5M extended cables SP3570-1055

13 3580 Series Electric Mortice Lock

Designed and manufactured in Australia, the 3580 series electric mortice is a high performance lock of superior quality. It is constructed from high grade zinc alloy, with a stainless steel latch bolt and face plate and is suited for all commercial applications.

The lock can be operated by push buttons, intercom systems and key switches; or integrated with electronic access control systems for use with higher security devices such as keypads or card readers.

The 3580 series is available in a wide variety of configurations to suit varying requirements and is especially suited to narrow style or short backset applications.

Key Features Available in non monitored and monitored versions.

Monitoring features: • Dead latched

• Door position/reed switch

• Key override

• Request to exit/REX

Available configurations: • Fail safe or fail secure

• 12Vdc or 24Vdc

• Field changeable monitoring contacts – normally closed, normally open Standards and Compliance • Field changeable handing - Left hand and right hand doors S2 (Security) Australian Lock Standard (AS4145.2.1993)

• Selection of free lever or locked lever on both D3 (Durability) Australian Lock Standard (AS4145.2.1993) sides of the door C-Tick Certified • Key override monitoring

• LED indication

14 assaabloy.com.au 3580 Series Electric Mortice Lock

Y 36.5 3 25 Y Limiting Dimensions X X

Dimension Backset 15 15

32 X 23 25.4 30 38 15 15

Y 36.4 39 43.6 51.7 212.5 155.5 90 18 28 18

79 260 260 1.5 1.5 15 20 15 46 24 1.5 46 24 1.5 32 32 Y

X 24 70 54 38 100 54 86 39 70 54 38 100 54 86 39 15 18

15 28.5 28.5 Reed Magnet 27 1.5 25 27 18 1.5 25

Accessories Ordering Information 260 3580 Series Technical Information 1.5 Product Description Part Number 15 Voltage Available in 12Vdc or 24Vdc 46 24 1.5 Current 12Vdc ± 5% 250mA (max) Anti-Clockwise Rebate Kit 32 Replace ## with finish code (SC, CP, PB) 3580-2902AC## 24Vdc ± 5% 125mA (max) Clockwise Rebate Kit LED Current When LED’s are fitted, add 15mA (max) to total current draw Replace ## with finish code (SC, CP, PB) 35802902CW## Monitoring Key override LED Assembly to suit 3570/3580 SP572-3129 70 54 38 100 54 86 39 Deadlatched and door closed 7.5m extended 9 wire cable SP3580-1052 Request to exit Hub/Deadlatch/Key override monitor: max ratings 500mA@30Vdc Door Status Monitor: max ratings 3W, 250mA (max) @ 12Vdc,28.5 Specification Statement 125mA (max) @24Vdc The lock should27 be capable of operation1.5 25 ° ° Environment Operational temperature range -20 c to + 60 c on voltages of 12 or 24Vdc and have a Case/ Cover High purity zinc alloy construction current consumption not more than Backset 23mm standard. 25.4, 30 & 38 mm extended available 250mA (max) @12Vdc and 125mA (max) Latch bolts 15mm Stainless Steel construction @24Vdc. Monitored locks must be capable Door Clearance 3 – 6.5 mm of monitoring the following functions: Door thickness Standard applications 32 to 50mm Key override, door position/reed switch Extension kits available & independent hub/ Request to exit. All Cylinder Standard Lockwood oval shaped cylinders monitoring outputs must have the ability to Cabling 3.6 metre length of cable with 9 pin socket supplied with each lock. be wired independently. The lock must be Recommended cabling: 18AWG (0.82mm²) cable runs up to 30m capable of operating fail safe or fail secure, Furniture Compatible with Lockwood series door furniture left or right hand, and have field configurable hub selection. Standard Finishes Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available

Note: For detailed electrical specifications, turn to page 18.

15 3580 Series Electric Mortice Lock

Ordering Procedure Sample Part Number 3582ELAM2RSC62 is made up of several sections. Choose your product by selecting an option from each section.

For example:

Backset Door Lock New Safety Sub Handing Finish Options Material Function Product Function Function 3 58 2 EL A M2 R SC 62

Backset Lock Function Safety Function Handing

23 mm 3 Vestibule lock 2 Fail Safe A Right Handing R (Power to lock) 25.4 mm 4 Combination Lock 4 Left Handing L 30 mm 5 Fail Secure E (Power to unlock) 38 mm 6 New Product Finish EL Sub Function Bright Chrome CP Door Material Polished Brass PB Non-monitored lock Metal 58 (0 Cylinders) N0 Satin Chrome SC Timber 59 Non-monitored lock (1 Cylinder) N1 Options Non-monitored lock 24 volt model 62 (2 Cylinders) N2 Monitored Lock (0 Cylinders) M0 Monitored Lock (1 Cylinder) M1 Monitored Lock (2 Cylinders) M2 Monitored Lock including KOM (0 Cylinder) M4 Monitored Lock including KOM (1 Cylinder) M5

KOM- (Key overrride moitoring)

Backset Nominate backset as required, eg 23mm 3

Door Material Nominate door material, eg Metal 358

Lock Function Select function, eg Vestibule Lock 3582

Electrical Variant Indicate that this is an Electric Lock 3582EL

Safety Function Select whether lock should be Fail Secure or Fail Safe, eg Fail Safe 3582ELA

Monitoring and Key Override Options Select monitoring and cylinders to be supplied,eg Monitored Lock with 2 cylinders 3582ELAM2

Handing Determine left or right handing, eg Right Handed 3582ELAM2R

Finish Specify appropriate finish, eg Satin Chrome 3582ELAM2RSC

Options Specify 24Vdc opion when required 3582ELAM2RSC62

16 assaabloy.com.au 3580 Series Electric Mortice Lock

Accessories Rebate kits to suit 13 mm rebated timber doors with a minimum backset 14 of 30 mm includes an adaptor to mount the lock and a special strike plate. 4 Handing of the rebate kits is determined by the opening movement of the 12.7 29 door on which the lock is fitted. 26.5 1.5

Finish Anti-clockwise Clockwise Satin Chrome 3580-2902ACWSC 3580-2902CWSC Bright Chrome 3580-2902ACWCP 3580-2902CWCP Polished Brass 3580-2902ACWPB 3580-2902CWPB

177 184 51 75

A

Extended Cylinders A A Extended cylinders should be considered when door thickness exceeds 50 mm or when the lock is mounted off centre in the door edge. A range of cylinders is available to suit various door thicknesses. Refer to ASSA ABLOY Australia Keying and Restricted Price List for further information.

“A” Cylinder Projection Cylinder Length Recommended Door Thickness

41 37 50 to 60 52 48 60 to 84 64 60 84 to 108 80 76 108 to 132 88 84 132 to 156

17 3580 Series Electric Mortice Lock

Electrical Specifications Circuit Diagram Note: Diagram depicts fail safe 12V RH opened door, with handle and key in rest state.

9 Pin Connector

1 Common Protection Red Solenoid Diode

2 Solenoid EXTERNAL 12V dc LED Resistor 3 Common Reedswitch Deadlatch and Green door closed status

NO C NC 4 Deadlatch and Hub Monitor door closed status Switch No. Lock Normal 1 2 3 4 Side Function 5 LED ON (1) OFF AN / C

ON 6 Hub monitor OFF AN / O (2) common ON OFF BN / C NO (3) ON C OFF B N / O LHS NC 7 Hub monitor Key Override Monitor Selection (4) ( LH/RH, NO/NC ) NO Set the 2 WAY DIL SWITCH to desired C (1) setting, refer to table. NC DIL NO RHS Switch No. Normal C SWITCH 1 2 Function NC 8 Key override ON (2) monitor ( NO/NC ) OFF N / O

ON DIL OFF N / C SWITCH 9 Key override monitor common

Pin Colour Function 1 Black Common (0Vdc) 2 Red Solenoid (12Vdc or 24Vdc) Plug Housing 3 Grey Deadlatch and door closed status (common) To power supply 4 Yellow Deadlatch and door closed status 5 Green LED

6 Brown Hub monitor (common) Receptacle 7 Blue Hub monitor (RH/LH, NO/NC) From electrical lock Housing 8 Orange Key override monitor (NO/NC) 9 Violet Key override monitor (common)

18 assaabloy.com.au Electric Mortice Locks

19 ABLOY EL402 Solenoid Lock

General Description ABLOY EL402 is typically used in the interior doors of business premises and educational buildings. The locks include a special double action bolt for quick and easy use and offer a cost-effective way of electric locking without compromising performance. The locks can be controlled by a variety of electrical impulse generating equipment such as card readers, keypads and timers. The locks can be connected to automatic swing door operators and are an excellent solution for access control systems. The new revolutionary adjustable backset feature offers unique flexibility that’s never been available before. Because of its symmetrical trigger bolt, ABLOY EL402 can be used in double swing doors. The lock can always be opened mechanically by key or by thumb turn and the bolt deadlocks automatically when the door closes.

Key Features • Field selectable Fail Safe/Fail Secure configuration

• Non Handed Symmetrical trigger bolt

• Visual Lock Status indicator

• Immediate release of Deadlocking

• Push or Pull operation

• Wide Operating Voltage

• Adjustable Backset Between 25 – 35 to suit most narrow style applications.

Applications • Offices

• Storage rooms

• Consulting rooms (All Narrow style)

• Top of glass doors 180° Note: The EL402 is not recommended • For use in doors with seal force

• For use in fire doors

Note: EL 412 & EL 413 are replaced with EL 402

20 assaabloy.com.au ABLOY EL402 Solenoid Lock

+ red 40 / 43 / 45 / 48 / 50 black 25 / 28 / 30 / 33 / 35 12 - 24 Vdc yellow blue 12 Common black 19 green

1.5 Locked yellow

5.5x2 Open blue 24

15 - 23.5 8 47.5

153.5

4 225 13 200

129.5

24 14.5 87

25

3 41.5 40

Specification Statement EL402 Solenoid Lock Technical Information The mortice lock must consist of High grade Voltage 12-24 Vdc -10%/ +15% STAB pure zinc alloy, the lock needs to have an Current 550mA (max) 240mA holding @12Vdc adjustable backset 25,28,30,33 and 35mm. 270mA (max) 110mA holding @24Vdc The latch bold must be no less than 14.5mm

Monitoring Microswitch 0.4A 30V AC with complete double action trigger. The (deadlock status) voltage must be variable between 12-24Vdc Environment Operational temperature range with tolerance of 10% up or down. The lock and -20°C to +60°C unlocked status must be fully monitored by

Case/Cover High Purity zinc alloy means of dry contacts.

Forend 25mm Ordering Information Backset 25, 28, 30, 33, 35mm (adjustable) Product Description Part Number Latchbolts Double action latch 14.5mm

Door Clearance 3-5 mm ABLOY EL 402 Narrow Style Electric Mortice Cylinder ABLOY classic or ABLOY Disklock Pro Solenoid Lock EL402

Cabling Recommended cable: 18AWG Cable 6m for EL402 EA211 (0.82mm2) cable runs up to 30m Accessories Furniture (Narrow Style) 4/0645 Furniture ABLOY Architectural Hardware

Standard Finishes Chrome plated forend, lock case yellow chrome plated

21 ABLOY EL502 Solenoid Lock

General Description ABLOY EL502 is typically used in the interior doors of business premises and educational buildings. The locks include a special double action bolt for quick and easy use and offer a cost-effective way of electric locking without compromising performance. The locks can be controlled by a variety of electrical impulse generating equipment such as card readers, keypads and timers. The locks can be connected to automatic swing door operators and are an excellent solution for access control systems. The new revolutionary adjustable backset feature offers unique flexibility that’s never been available before. Because of its symmetrical trigger bolt, ABLOY EL502 can be used in double swing doors. The lock can always be opened mechanically by key or by thumb turn and the bolt deadlocks automatically when the door closes.

Key Features • Field selectable Fail Safe/ Fail Secure configuration

• Non Handed Symmetrical trigger bolt

• Visual Lock Status indicator

• Immediate release of Deadlocking

• Push or Pull operation

• Wide Operating Voltage

• Backset 50mm

Applications • Offices

• Storage rooms

• Consulting rooms

Note: The EL402 is not recommended; • For use in doors with seal force

• For use in fire doors

Note: EL 512 & EL 513 are replaced with EL502

22 assaabloy.com.au ABLOY EL502 Solenoid Lock

+ red 75 black 50 12 - 24 Vdc yellow

37.5 blue

29 Common black green 12 Locked yellow 19 Open blue 6.5

25.5 - 15 102 8 10.5

6.5 30

4 105 147 225 13 203 14.5 24

5.5 30

22

3

Specification Statement EL502 Solenoid Lock Technical Information This mortice lock must consist of High grade Voltage 12-24 Vdc -10%/ +15% STAB pure zinc alloy, the lock needs to have a Current 12V Max 550 mA, Normal 240mA backset 50mm. The latch bold must be no less 24V Max 270mA, Normal 110mA than 14.5mm with complete double action

Monitoring Microswitch 0.4A 30V AC trigger. The voltage must be variable between (Deadlock status) 12-24Vdc with tolerance of 15% up or 10%

Environment Operational temperature range down. The lock and unlocked status must be -20°C to +60°C fully monitored by means of dry contacts. Case/ Cover High Purity zinc alloy Forend 22mm Ordering Information

Backset 50mm Product Description Part Number Latchbolts Double action latch 14.5mm

Door Clearance 3-5 mm ABLOY EL 502 Electric mortice Solenoid Lock EL502

Cylinder ABLOY classic or Abloy Disklock Pro Cable 6m for EL502 EA211 Scandanavian oval type

Cabling Recommended cable: 18AWG (0.82mm2) cable runs up to 30m

Furniture ABLOY Architectural Hardware

Standard Finishes Chrome plated forend, lock case yellow chrome plated

23 ABLOY EL580 Solenoid Lock

General Information ABLOY EL580 Locks are suitable for interior or exterior doors of business premises and the exterior doors of apartment buildings and detached houses.

Abloy EL580 is suitable for use in exit doors as the inside handle is free for egress at all times. The locks are automatically deadlocked from the Exterior when the door is closed. The locks can be controlled by a variety of electrical impulse generating equipment, such as a card reader, keypad and timer.

Key Features • Interchangeable handing • Changeable function of handle control • Configurable fail safe or fail secure • 12-24Vdc operating voltage • Configuration of deadbolt either 14mm or 20mm • Increased protection against manipulation • Low current feature while continuous control

Applications • Offices • Storage rooms • Consulting rooms • Fire Doors

EL580 Solenoid Lock Technical Information Specifier Statement The mortice lock must consist of High grade Voltage 12-24Vdc -10%/ +15% STA pure Zinc alloy The lock needs to have a backset Current 12V Max 550 mA, Normal 270mA 24V Max 240mA, Normal 110mA of 50mm. The latch bolt must be configurable between 14 - 20mm. It also needs to be field Environment Operational temperature range -20°C to +60°C selectable for the fail safe and fail secure Case/ Cover High purity Zinc alloy construction configuration. The voltage must be variable between 12-24Vdc. The following parts need to Backset 50mm be fully monitored; bolt position, handle down Latchbolts Bolt throw: 14mm or 20mm configurable and REX by means of dry contacts. Cylinder Scandinavian Oval or Finnish type cylinder Cabling Recommended cable: 18AWG (0.82mm2) cable runs up to 30m Furniture ABLOY Architectural Hardware Standard Finishes Chrome plated forend

Ordering Information

Product Description Part Number

ABLOY EL580 Electric Mortise Solenoid Lock EL580 Cable 6m for EL580 EA210

24 assaabloy.com.au Electric Mortice Locks

25 ABLOY EL648 Motor Lock

General Information The EL648 is a heavy duty motor lock with hook bolt for narrow style doors. They provide superior mechanical strength against physical attack. The EL648 is used in high security auxiliary lock in applications such as gates and exterior doors of industrial premises, shopping centres, business premises etc. The lock is especially suited for sliding doors as it can be installed in the door frame or the door leaf. EL648 is ideal for night locking that requires greater strength and security. The lock can be controlled by a variety of electrical impulse generating equipment such as a card reader, keypad or timer. This lock is suitable for use with sliding door operators.

Key Features • High security motor bolt.

• Lock case is connected with a separate control unit.

• 12-24Vdc operating voltage

• Configuration of deadbolt either 14mm or 20mm

• Increased protection against manipulation

• Striker plate includes door position magnet.

• Fully monitorered, bolt in/bolt out, door position manual operation

• Can configure lock in fail safe and fail secure (Backup card required to set the lock case to go to desired position in case of power failure) Note: Lock requires EA460 Control unit to operate.

26 assaabloy.com.au TECHNICAL DETAILS APPLICATION ® Operating voltage 12 - 24 V DC (+15%) stab. ABLOY EL648 and EL654 are used as high security auxiliary locks e.g. in gates and 12 V AC (-10%/+50%) RMS exterior doors of industrial premises, shopping centres and business premises etc. The Current Normal 150 mA locks are especially suited for use in sliding doors as they can be installed in door frame Idle 70 mA or door leaf. Max. 750 mA ABLOY® EL654 can be installed together with e.g. EL402, when both locks can be Adjustable delay 2..15 sec controlled individually. EL402 has a double action bolt for quick and easy locking and is Temperature range -20oC...+60oC well suited for doors that are frequently used in daytime. EL654 is ideal for night time Hook bolt 22 mm locking that requires greater strength and security. Backset 25, 35 mm Both ABLOY® EL648 and EL654 can be controlled by a variety of electrical impulse Forend 25 mm generating equipment, e.g. card reader, keypad or timer. The locks are suitable for use with door automatics. FINISH Available also: EL655 compatible with Finnish type cylinder. Chrome plated forend ABLOY® EL654 and control unit EA470 are ASSA ABLOY Hi-O Technology TM certi ed products. CYLINDERS - Scandinavian oval type; ABLOY® PROTEC, ASSA, FUNCTION RUKO, TrioVing or other. Bolt is withdrawn and thrown by motor. Lock case is connected with a separate control ® ® - Finnish type; ABLOY CLASSIC or ABLOY unit included in the lock package. Striker plate EA300 with integral door contact must PROTEC be used with the lock. After an opening impulse hook bolt is withdrawn. After door use or delay, the hook bolt is released immediately. PACKAGE ABLOY® EL648 can be con gured to fail locked or fail unlocked mode in case of power Lock case, control unit, striker plate EA300 withABLOY EL648 failureMotor (requires Lock a backup card connected to the EA460 control unit). door contact, connection plugs, xing screws and ABLOY® EL654 enables data communication between lock case and control unit EA470. lock case manual. When installed together with EL480 / EL482 / EL402 / EL490, the lock offers the following options for operation: - both locks are deadlocked - EL480 / EL482 / EL402 / EL490 is DIMENSIONS deadlocked, EL654 is open

����� - both locks are open  ����� ��

  �� WIRING PRINCIPLE ��

���� ����

 EL���� 648

! %#!& %  

����

��

  ���  ��  ���� 

��� !$  " ���  

!!#  �� ��� 

 

 �� !% ' 

     !!#! %% !%   ����   %$%##

 ��� "% $  &&$ !% &$

� &%*(&#+%!*  

��� EL654   -! * '%  ��

           Specification,$ Statement    EL648 Motor Lock Technical Information  #&"  +(!*-&#* &'% The mortice lock must consist of high grade pure Voltage 24Vdc ± 15% stabilised zinc alloy. The bolt must be controlled by means of #&"  +(!*-&#* &'%  

Current Idle 70mA, Normal 150mA and motor and the  shape of the bolt must be in hook &&()**+)   Max 750mA shape for added security. A separate controller * #&"  Monitoring Door position, Bolt Position needs to be connected to the lock to enable trigger  &&( Mechanical trigger and monitoring functions. The voltage must be

 Environment Operational temperature range variable between 12-24Vdc with tolerance of 15% up or down. The following parts need to be fully  -25°C to +70°C Case/ Cover High purity Zinc alloy construction monitored; bolt position, door position by means  Backset 25mm or 35mm of dry contacts. The lock must be suitable for internal and external use. Latchbolts Bolt throw: 22mm Hook bolt  Cylinder Scandinavian oval type, Finnish type Ordering Information (Please order separately) Cabling RecommendedCYLIND cable: 18AWG ERS AND ACCESSORIES (0.82mm2) cable runs up to 30m Product Description Part Number Furniture ABLOY Architectural Hardware CYLINDERS ACCESSORIES Standard Finishes Chrome plated steel forend, yellow ABLOY EL 648 Electric mortice Solenoid Lock EL648

chrome, lacquered lock body. Cable 6m for EL648 EA214 SHORT ABLOY® LEAD BACKUP Strike plate with integrated magnetCABLES EA300 CONNECTION This document may not be used in the installation of PROTEC COVERS CARD (EL648) Accessories CABLE (EL654) a lock. Drilling and wiring diagrams ans installation Control Unit EA460

Single with EL648: instructions are included in the lock case manual, thumbturn CY201N / 6415 EA214 (6m) EA235 (EL490) EA280 which is included in each lock case package. EA224 (10m) EA236 (EL402, 952169 EA281 We reserve the right to make alterations to the EL654: EL480, EL482) CY202N / 6412 EA216 (6m) Double products described in this leaet. CY044N EA226 (10m) CY065N

AbloyAbloyAbloy Oy Oy WahlforssinkatuWahlforssinkatuWahlforssinkatu 2020 20 27 P.O.P.O. BoxBox 108108 P.O.BoxFI-80101FI-80101 108 JOENSUUJOENSUU FI-80101FINLANDFINLAND JOENSUU www.abloy.com FINLANDTel.Tel. +358+358 2020 599599 25012501 Tel.FaxFax +358 +358+358 2020 20 599599 599 22092209 2501 Fax +358 20 599 2209 12/2008 1.000 kpl Suomen Painotuote, Joensuu 8801231 12/2008 1.000 kpl Suomen Painotuote,

Abloy Oy is one of the leading manufactures of locks, locking systems and architectural hardware and the word´s leading developer of products in the eld of electromechanical locking technology. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. Power Transfer Lead

Lockwood Power Transfer Cover LC8810 The LC8810 and LC8811 Power Transfer Lead Covers are designed to ensure unbroken transfer of wires between door and frame in electric locking situations.

Features: • Provides unbroken connection from controller to lock, for cable up to 8 mm diameter.

• Vandal-resistant chrome plated steel flexable.

• Completely concealed when the door is closed.

Applications LC8810

The LC8810 is a shorter unit suitable for hinged doors which open to 90° (maximum of 120°).

LC8811 The LC8811 is designed for use on doors which open more than 120°, or have a gap from pin hinge to door frame of more than 20 mm. NB. Not suitable for centrally pivoted doors.

Standards and Compliance

4 Successfully fire rated up to 4hrs on fire door assemblies Hour in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets)

28 assaabloy.com.au Power Transfer Lead

LC8810 LC8811 The LC8810 is a shorter unit suitable for hinged The LC8811 is designed for use on doors which doors which open to 90° (maximum of 120°). open more than 120°, or have a gap from pin hinge to door frame of more than 20 mm. NB. Not suitable for centrally pivoted doors.

90° 120° 120°

Door Frame Door Frame

29

20

29 O 10

29 20

O 10

29 20

O10 20

O10

460

460

O12

O12

250

478 250

478 258 258 299

519 299

519 543 543 32 3 32 3 O12 O12

O12

O12

17

23.8 O12 17

17

23.8 O12 17 17

Ordering Information 17

Product Description Part Number

323mm Power Transfer Cable LC8810 543mm Power Transfer Cable LC8811

29 ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. ASSA ABLOY is represented in all major regions, in both mature and emerging markets, with leading positions in Australia, Europe and North America. As the world’s leading lock group, ASSA ABLOY offers a more complete product range of door opening solutions than any other company on the market.

tbc copy

Head Office ASSA ABLOY Australia Pty Limited 235 Huntingdale Road, Oakleigh Victoria, 3166 Australia

1300 LOCK UP (1300 562 587) [email protected] The global leader in assaabloy.com.au door opening solutions AAA-CAT-069 0609 MS0458 AAA-CAT-069

ASSA ABLOY Australia Pty Limited ABN 90 086 451 907 ©2009