Po s -~ -J

~ ...... ~

LIBRARY FISHERIES AND OCEANS BIBLJOTHEQUE ricnEs ET oct.\Ns

DEPARTMENT OF FISHERIES AND OCEA NS

lVV Al9 ·s·N 'H1now HIVO 900 L XC: 9 AHdVll~ONV3:>0 :10 :IJ.OJ.1.LSNI Oll0:10:19 Al1Vll911 :JHJ.

PLANT INSPECTION PROCEDURES

Plant Services Section Southern Operations Di rectorate Western Region 501 University Crescent Winni peg, R3T 2N6 Phone: 949-5096 April , 1984 ii

TABLE OF CONTENTS ======Page

List of Figures . ii i List of Tables iv List of Abbreviations v

Plant Registration Program l

Cold Storage Procedures • 111

Approved Pest Control Program • 114 Plastic Tub and Wood Box Storage • 122 Multi-Purpose Plants • 125 Field Procedures - Water and Ice Sources • • 132

In-Plant Bacteriological Surveys • 138

The Membrane Filter Technique • 144

Water and Ice - Samples and results 1983/84 . 127 ii i

LIST OF FIGURES ======Page

Figure 1 - Certificate of Registration ...... 8 Figure 2 - Team Survey Form ...... 80 Figure 3 - Fish Plant Report • ...... 88 Figure 4 - Sanitarians Check Sheet • ...... 93 iv

LIST OF TABLES ======Page

Table 1 - Registered Plants Classification Listing 19 Table 2 - Unregistered Plants Classification Listing • 39

Table 3 - Minimum Compliance Standards for F.I.R. 94

Table 5 - List of Acceptable Materials and Compounds • 113 Table 6 - Geometric Means Calculation - Water and Ice 136 v

LIST OF ABBREVIATIONS USED THROUGHOUT THE PLANT INSPECTION PROCEDURES (PIP) MANUAL ======

ASAP as soon as possible Department refers to the Department of Fisheries & Oceans FIA Fish Inspection Act FIR Fish Inspection Regulations FFMC Freshwater Fish Marketing Corporation FPR Fish Plant Report form HQ (Regional) Headquarters OPMS Operational Performance Measurement System PIP Plant Inspection Procedures manual Reg. registered plant Reg. no. registration number TS team survey UR unregistered fish processing plant II <~ 0::: {.!J 0 0::: 0.. z 0...... I- < 0::: I- ...... V) {.!J L1J 0::: I-z <_J 0.. - 1 -

PLANT REGISTRATION PROGRAM

A) Review Procedures 1) Survey Requisites Section 14 of the FIR states that all processing of fish for export is to be carried out in a registered plant. Plants should not be permitted to process fish for export unless they are in possession of a valid Certification of Registration. NOTE 1: This excludes fisherman-packer operations (where a fisher­ man does his own dressing, packing or icing of fresh fish from his own catch). NOTE 2: Each plant will be reviewed on a management basis so that team surveys will not be carried out if the intention is not to register such a plant. Ability to monitor plant operations and maintenance of sanitation standards at field level are important factors that must be taken into consideration prior to registering any plants. Plants that will be assessed for registration include: a) all processing plants (other than whose which just ice and hold fish) where ownership of the fish changes hands, e.g. where fishermen deliver fish to a plant which takes the fish from the fisherman and the plant then exports the fish directly or delivers to the FFMC. This would include all delivery points and agents of the FFMC. It would not include fishermanpackers or plants that process fish for local sales only. b) those plants whose owners request registration, in writing to the District Office. - 2 -

Plants will be considered for team surveys if: a) District and local officers feel that the plant essentially complies to FIR, and that they are able to monitor plant operations and sanitation standards adequately, b) water and ice have been sampled and found to be satisfactory (or water is from an approved municipal source). Plants presently registered will be team surveyed in accordance with Plant Classifications. Fish plants with temporary registration certificates shall be

re~-eva l uated prior to the expiry date and wi 11 be team surveyed where extensive renovations have taken place, at District request or Regional request 2) J§!am Survey Procedures Team surveys were initiated to provide a uniform approach to the inspection of fish processing plants and the to implementation of corrective measures. Completed Fish Plant Report (FPR) forms and other reports from the field are used as sources of information for all plants. Any p1ant not team surveyed in a particular year remains subject to continuing vigilance by the local officer who will ensure that such p1ants are reviewed, on a yearly basis, for construction, equipment and operating requirements using the Fish Plant Report form. The team survey form is used in reassessing registered plants for continuance of registration and assessing unregistered plants where it is felt that those plants comply with the FIR and meet the requirements for assessment. Team surveys of fish processing plants will be carried out - 3 - by an inspection team composed of the local inspector and/or district representative and a regional office representative. The field officer will advise on local conditions, plant problems and concerns during the survey. It is also the officer's responsibility to check and ensure that the deficiencies noted during the survey have been corrected and to inform District office of plant progress. The District representative ensures that the local officers are being uniform in their approach during the survey; monitors p·lants in the district and recommends registration or withdrawal to Regional office. The Regional representative is responsible for maintaining a consistent approach to regulatory requirements and to the uniform correction of deficiencies throughout the Region. During the survey the Regional representative will complete the team survey form in conjunction with the district and/or local officers. Where on-site agreement is reached between team members, the Regional representative wi 11 ensure that the pl ant manager receives a copy of the defi ci ,ency list and corrective dates as well as sending a copy of the team survey and a sketch of the plant and equipment layout to the District office. Plant managers are to be advised of the survey intent and procedure prior to commencement of the survey. A team survey will record all plant construction and operational deficiencies as well as noting equipment present, flow of operations and any other details which might be relevant to the decision to issue a registration certificate (e.g. chemical compounds used as disinfectants or pesticides should be included). - 4 -

NOTE: Team surveys should be conducted when plants are processing so that operational deficiencies can be recorded. They should be completed as near to the start of the operating season as possible to permit registration to be granted where necessary. Team surveys in a particular area will commence only when the plants are known to be operating since the survey may take considerable time and attention as documentation of construction, equipment, and operational deficiencies must be accurate. It is essential that all deficiencies be noted and recorded so that overlooked deficiencies are not "discovered" at a later date. The observations of team survey personnel are recorded on the Team Survey Form (see Figure 1). Photographs are an integral part of the team survey and follow-up inspections and should be taken of the plant exterior and interior, including the basic processing area, equipment, processing activities and specific deficiencies observed. Photos are labelled to correspond to a diagramatic sketch of the plant in order to show plant layout flow of production and operations. The deficiencies recorded by the team will be discussed among the members prior to any discussions with management or plant owners. Agreement on the nature of deficiencies, suitable methods and suggested deadlines for their correction will be settled among team members. Where agreement is not reached, the discussion between the team members should be continued away from the plant until settlement is reached. The plant manager should be informed that the deficiency list will be sent out to him and that he is to comply with the correction deadlines. (Items agreed upon by a 11 team representatives are discussed with him before the team departs.) - 5 ..

The advantages to leaving a copy of the deficiency list with the plant manager are as follows: - The local inspection and/or District officer has time to read over the deficiency list before discussing the 'list with the plant manager. - It prevents discrepancies due to rewriting of the list whereby the original meaning may be inadvertently changed. - There is the opportunity to discuss the list with the plant manager while all the inspectors are present. - The plant manager has the opportunity to question any wording, phrasing or deficiencies at the time. - Specific deficiencies can actually be pointed out to the manager to avoid misinterpretation. - No new deficiencies are discovered that are written to the plant manager which were not mentioned to him while discussing the deficiency list. - Most important is the time factor. The plant manager already has the list and can begin corrections immect·iately. Major deficiencies are those items which are more conspicuous in effecting product contamination. They generally are not ab.le to be corrected within 30 days. Examples of major deficiencies include: Schedule I - Section 1 - floor cracks (that prevent proper cleaning) in working area floor surfaces Section 3 - drains of insufficient capacity Section 4 - wall cracks Section 5 - inadequate ventilation where humidity and odour pose an obvious problem - 6 -

Section 8 - no handwash or hand dip facilities Section 9 - unsafe, unsanitary water Section 11 - surfaces of porous material Section 16 - cracked, chipped ceilings with open joints NOTE: Suspected structural defects should immediately be brought to the attention of the plant owner/manager and reported to the District Manager for consultation with the Regional Inspection Engineer. Minor deficiencies can generally be corrected within 30 days. ·All unsanitary operating practices may be major in effect, but can be considered as minor for survey purposes where the deficiencies can be corrected immediately. Operational deficiencies (e.g. packer using unsanitary gloves) causing product contamination or deterioration must be corrected immediately. Operational deficiencies which are not of an urgent nature (such as insufficient lighting over a process area) generally require correction within 30 days. Deficiencies resulting in hazardous conditions to personnel, e.g. unsafe wiring and suspected structural defects, should immediately be reported to Regional Headquarters and plant management. Construction deficiencies should be corrected prior to commencement of a particular fishing season and their correction deadlines should be set prior to season commencement. Monitoring the correction of these deficiencies ?hould be similarly geared to the fishing seasons. Construction or equipment deficiencies that are causing product contamination or deterioration should not be allowed. - 7 -

A deficiency list will be sent to the District office from

Regional Headquarters. The District office will forward a copy to the

plant owner (if different than the plant manager) and to the local

inspector. A copy of the complete Team Survey Form incl ing a sketch

of the plant will be sent from Regional to District office.

If the survey team is in agreement that the plant being

surveyed complies in all respects to regulatory requirements or that

the deficiencies that exist do not constitute a product contamination

hazard under satisfactory operation conditions, the Regional

representative wi 11 then make a recommendation for regi strati on to

Regional management.

Recommendation for registration from the District lev1e·1 are

to be submitted to Regional Headquarters and the following should be

included in their reports:

- Team survey with photographs showing deficient items as well as

general pictures of plant.

- A11 deficient items to be noted on survey forms. Those items that

are corrected before the survey teams leaves the plant are to be

duly noted as being corrected on the team survey form.

- Follow-up inspection showing corrected deficiencies as were recorded

on the team survey.

- Satisfactory water and ice bacteriological dates (from reports

sent to R.H.Q.)

Regional Headquarters will forward certificates to Districts

for mounting, framing, and distribution. Certificates of Registration

will be mounted in a durable frame and are to be accompanied by a

letter from District office with information pertaining to whether Government of Canada Gouvernement du Canada I+ Rsheries and Oceans Peches et Oceans CERTIFICATE CERTIFICAT OF REGISTRATION D'ENREGISTREMENT TYPE OF OPERATION REGISTRATION No. Genre d'exploltation

NO d'enregistrement NAME OF FIRM Raison soclale

CX) LOCATION OF ESTABLISHMENT Situation de l'etablissement

This certificate is issued in accordance with the Fish Le present certificat est delivre en vertu du Reglement Inspection Regulations and the conditions prescribed sur !'inspection du poisson et des conditions qui en de­ thereunder. coulent.

...... t t 0 0 0 t t t 0 to 0 t t t t t t t I 0 t t t t t I 0 t t t t 0 t t t t t It 0 t t t t 0 t t 0 t t DATE OF ISSUE DELI\'RANCE REGIONAL DIREC1DR DIRECTEUR REGIO:-\,\L - 9 -

they are continuing or temporary and that they must be displayed in a prominent location within the plant. B) Continuing Certificates of Registration (no expiry date) Continuing certificates are permanent provided that the plant maintains acceptable standards of operation, corrects any deficiencies noted within agreed time frames, and keeps the plant and equipment in satisfactory repair. NOTE: Assessing priorities for the completion of team surv,eys of processing plants will be based upon the plant classification list. In addition, the following criteria can be used to assist Districts in final survey priorities: - plants that are operating should be team surveyed before plants that are not yet in operation, - plants that are FFMC agents or delivery points or those that export directly should be team surveyed before other plants, - existing plants with expired temporary registration certificates should be team surveyed as soon as possible to determine their suitability to continue to process for export. - new plants will be team surveyed following District s recommendation for registration. Any registered plant not team surveyed in a particular year is to be formally reviewed by the local officer using the Fish Plant Report Form. C) Temporary Certificates of Registration (with expiry date) Temporary certificates are generally issued to new plants requiring registration if numerous deficiencies exist and they cannot comply fully to FIR but through exemptions or other circumstances, they are permitted to operate. Certificates are also issued to plants undergoing extensive - 10 - renovations. Temporary certificates provide a reason for closer checks to be made on these plants to ensure satisfactory compliance within correction deadlines. They will have a maximum effective duration of 12 months and will not be extended except under highly unusual circumstances and with the approval of Regional Headquarters. An extension can be granted in writing by District office upon consultation with Regional office. If extensions are granted and comp.liance is still not met, temporary registration will be withdrawn and correspondence forwarded by R.H.Q. to the FFMC agent or head office, where appl-icable, indicating that the plant does not meet registration requirements and that products from the plant will not be permitted for i nter-provi nci al or export markets. Wh1en temporary Certificates of Registration are issued they will be accompanied by a letter from District office explaining the significance of the term "temporary" and outlining the deficiencies and correction deadlines.

On the Certificate of Registration the words 11 expiry date" with an appropriate date will be typed in the space located beneath the words "Location of Establishment". A temporary certificate's expiry date will be one month later than the deadline given to the plant for deficiencies correction date to allow sufficient time for follow-up surveys and recommendations to be sent from District office to Regional office to issue a continuing certificate where warranted. A letter from District office (copy to Regional Headquarters) stating that a certificate will no longer be valid as of the expiry date is to go to each olant one month prior to that date. This letter is to explain to the plant operators that all fish destined for the export market must be processed in a registered plant. A request should be made to the plant operators to - 11 -

(upon expiry) remove the certificate from display and send it to the District office or to give it to the local inspector at such time when ey are in the area. If a plant has been team surveyed and issued a temporary certificate to allow elimination of existing deficiencies, no further team survey is required, unless major renovations have taken place or it is request by the districts. A follow-up survey by the District office will be conducted using the Fish Plant Report form. The next team survey will be as per the plaint classification list. The survey form, along with water and ice bacteriological report and photos is to be sent in to the Regional office as per established procedures.

D) Fo 11 ow-up Plants should be followed up within one month prior to correction deadlines. Failure to effect deficiency corrections as documented by the local officer within agreed-upon t·ime frames will be cause for issuing a warning from District office. If, after required visits, meeting th plant management and documentation has taken place and compliance is still not met, Reaional office is to be informed and a warning, via a registered letter from the District, is to be sent to the plant (cc to Regional office). If this warning is not heeded, as documented by the local officer, the District office may recommend withdrawal of registration to Regional Headquarters who may take action to inform the plant that their Certificate of Registration has been withdrawn and they can no longer process fish for export (copy to District office). If the plant is an FFMC agent, the FFMC head office ll also receive registered correspondence informing them of the withdrawal. Local officers will contact their District Managers to determine what action is to be taken when withdrawal of registration is being contemplated. - 12 -

E} Refusal of Certificates of Registration If numerous and extensive construction and/or operational deficiencies exist, registration may be withdrawn for plants with registered status or withheld from plants seeking new registration. Registration should be withdrawn or withheld when deficiencies exist and are accompanied by a refusal from plant management to correct them. Withdrawal of a registration certificate requires written authorization from Regional Headquarters. Necessity for plant action due to non-compliance to the FIR results when: 1) A plant has structurally deteriorated 1 over the years and does not meet construction requirements, and/or 2) a plant develops a santiation problem that may effect product quality. If a plant is operating under unsanitary conditions which may lead to product contamination 2 then the local officer should react immediately to ensure that the situation does not continue. If necessary, the processing of fish is to be temporarily disr~pted and product put under detention until the operation is cleaned up. Photos are to be taken accordingly. District and Regional office should be contacted immediately after full documentation of the situation has been made, e.g. photographs and completion of a plant inspection form.

If there is any concern that the product may be contaminated then the lot should be placed under detention and samples drawn and analysed immediately. The lot may be shipped to FFMC, Winnipeg under detention to have samples taken and tests carried out by the Department.

Deterioration in construction that may render the plant unsafe to work in or an unsanitary environment to process fish in. 2 The possible rendering of product as unfit for human consumption as defined by the FIR as tainted, unwholesome or decomposed. - 13 -

Local conditions are factors that influence whether the plant process for export and/or ship under detention. Conditions such as the economic situation, proximity of other fish processing agencies, number of fishermen, etc. should be considered. These factors must be discussed at local, district, regional and industry levels to obtain a mutual satisfactory solution.

If gross unsanitary conditions (i.e. conditions resulting in obvious product contamination) exist, provincial public health officials, conservation officers and the FFMC should be contacted through consultation Regional Headquarters. Complementary provincial legislation may assist eld officers in dealing with this type of occurrence. Each situation is to considered unique and will be evaluated accordingly. If the unsatisfactory plant is in close proximity and easily accessible to a federally registered ant, tne fishermen should be directed to the registered plant until proper ean-up of the unsanitary plant has taken place. However, if this is not possi e, then detained product should be allowed shipment to FFMC, Winnipeg and samples taken for inspection. If regi strati on is withdrawn and the operator continues process for export, advice should be obtained from the District Manager as to tne course of action.

The District Manager will contact Regional Headquarters for advice on product and plant action. Legal prosecution, when applica e, will be initiated by Regional Headquarters.

Certificates of Registration will also be withdrawn en of following conditions occur: - 14 -

a) plant is sold, has ownership transferred or has name changed under present ownership. (NOTE: In such cases, re-registration will

follow normal proced~res as quickly as possible so that normal plant operations are not unduly delayed.) b) plant ceases operation for more than one calendar year or plant has indicated it is permanently closing. If it is not possible to remove the certificate (due to plant being padlocked, destroyed or ·inaccessible, etc.), a registered letter is to be mailed from District off·ice to the plant owner (copy to Regional Headquarters) stating that registration has been withdrawn and the Certificate of Registration is to be returned to the District office. The letter should also state that processing fish for export ii s not a 11 owed in an unregistered establishment and that if re-registration is considered at some future date, a survey will be required under standard registration procedures. The local officer should arrange to remove an invalid certificate at first opportunity. F) Re-issuance of Certificates of Registration Issuance of a plant registration following withdrawal will require a team surve_y, compliance with FIR at that time, and unanimous recommendation by the survey team to Regional Headquarters. (Name changes may not necessarily require a team survey where ownership has not changed and the pl ant still meets registration requirements.) Pl ants which are not up to standards for re-issuance of a temporary or continuing certificate will be considered as unregistered plants and will not be allowed to process fish for export. G) Plant Classifications A systematic program which provides a constant check on plant construction, equipment and operating requirements is essential to the - 15 -

monitoring of plant sanitation, employee hygiene, operating conditions and equipment performance.

/I. classification system which lists "good", "fair" and "poor" plants will assist the field inspector in his efforts to monitor continually changing p1 ant conditions and thereby concentrate his activities on non-compliance items in poor plants. Team surveys and Fi sh Pl ant Reports wi 11 be carried out on a 1ess frequent basis in good plants while more inspection effort will be required on poor plants. Districts must be constantly alert for any change in good or fair plants which might result in a change of classification because of non-compliance items. Classification lists will be used by Regional and District offices to determine and initiate action for problem plants. Discussions will be held, when appropriate, with other federal and provincial agencies and with industry to selectively choose those plants which require repair, renovation or replacement. Plants with C classification are to receive priority in inspection surveillance and up-grading procedures. Plant classifications will be found on the plant classification list

(Registered plants - Table 1, and Unregistered Plants - Table 2.) H) Registered Plants Classification Criteria The procedures to be followed ln determining Plant classifications are as follows: Classification A Information from previous surveys and pl ant report data indicates no major and few minor deficiencies which can be corrected within 30 days and which do not create any hazards to products or personnel. - 16 -

There are no structural or construction faults which would be considered to be incompatible with other federal or provincial regulatory agency requirements. There are no outstanding deficiencies which have not been rectified by management past mutually agreed upon dates of correction. Plants in this classification should be team surveyed at least once every three years. Fish Plant Reports are required on all plant/product inspections and data continually reviewed to ensure changes in deficiencies are reflected, where necessary, by change in plant classiification. Continuing Certificates of Registration should be issued for plants in this classification. Classification B Plants in this classification have major and numerous and extensive minor deficiencies. Major deficiencies which are present may lead to product contamination. There are no structural faults which would be considered to be incompatible with other federal or provincial regulatory agency requirements. There may be outstanding deficiencies which have not been rectified within mutually agreed upon dates of correction because of numerous deficiencies and delays in receiving materials and supplies. Plants in this classification should be team surveyed at least once ever:y two years. Fish Plant Reports are required to ensure follow-up on deficiency corrections by mutually established correction dates. - 17 -

Classification C

Plants in this classification have major and minor

deficiencies which may create an unsanitary processing environment and

potentially hazardous conditions to plant personnel. Extensive 1N"ork is

required over extended periods of time and/or complete facili

replacement has been recommended.

There may be structural or construction faults considered to

be incompatible with other federal or provincial regulatory agency

requirements.

Such plants are considered as unsatisfactory processing

environments for products intended for human consumption.

Plants in this classification should be team surveyed every

year and Fish Plant Reports are to be used to monitor conditions on a

continuous basis.

Certifications of Registration will not be issued for plants

in this classification. Regional Headquarters is to be notified of

registered plants considered to be a "C" classification and steps will be

taken to remove the registration certificate where corrections have not

been made.

Normally, such plants should not be permitted to operate past

the year in which "C" classification has been designated. Consultation

with other federal and provincial agencies and industry should commence as

quickly as possible. Regional Headquarters must be involved in such

discussions and any resulting actions.

If the "C" classified plant is an agent of the Corporation,

Regional headquarters will irrmedi ately notify the FFMC to arrang1e for

meetings to deal with Inspection requirements. - 18 -

The main emphasis in dealing with "C" plants should be to upgrade and improve the facilities. Closure should be a last recourse and only after sufficient discussions with plant operators, notification of the intent to shut down operations and documentation of the deficiencies have taken place. (See procedures under E - Refusal of Certificates of Registrations.)

Registered Fish Processing Plants

CLASSIFICATION

A B c

MANITOBA 33 10 a

SASKATCHEWAN 6 6 0

ALBERTA 8 1 0

N. l1J. T. 3 3 0

TOTAL OUTLOOK FOR TOILET FACILITIES Toilet type

__ PL2 ______p[! ______fL! ______~! __

MANITOBA 4 6 32 1

SASK. 5 0 7 0

ALTA. 1 1 7 0

N.W.T. 2 1 3 0 Total 12 8 17 1

0/ /0 17 11 70 2 - 19 -

KEY FFMC: A = agent or delivery point of the FFMC Reg. No.: Registration number Type: Type of registration certificate C = continuing or permanent T = temporary

Type of Operation: f p = fisherman-packer h = holding i = icing p = packing d = dressing SC = scale and wash f i filleting fr = freezing lake fr = lake frozen c = comminuting sm = smoking pi = pickling or marinated pr = further processing no = not operating months - months that the pl ant operated last year (indicated by "o") Date last TS = Date of last team survey completed Water Test Date= Date of last sampling of water Ice Test. Date = Date of last sampling of ice * Bacteriological results on water and ice are included in E.D.P. Action Reports

Toilet Types in Re~gistered Plants p/o - privy/outhouse p/t - private residence toilet f /t - flush toilet in plant c/t - chemical type toilet - 20 -

PLANT SERVICES REPORT FROH 83/04/01 TO 84/03/31

~------~~~~~------~-~~

ALB SASK MAN NIH SUBTOTAL TOTAL R u R u R u R u R u OPERi\TI OHS SUMMARY: ------TOTAL HUMBER OF PLANTS 7 4 12 104 41 229 6 26 66 363 429 NUMBER OF OPERATING PLANTS 7 2 12 33 41 163 6 4 66 202 268 IHSPECTIOHS SUMMARY!

------~------HO. OF INSPECTIONS 104 1 157 24 275 181 87 9 623 215 838 NO. OF FOLLOW-UP INSPECTIONS 3 2 43 6 20 20 4 1 70 29 99 NO, OF SURVEYS 0 1 68 0 1 1 2 0 71 2 73 PLANTS INSPECTED 6 1 12 a 38 101 5 5 61 115 176 PLANTS FOLLOW-UP INSPECTED 2 2 10 4 14 17 3 1 29 24 53 PLANTS SURVEYED 0 1 7 0 1 1 2 0 10 2 12 LEVEL ACTIONS C2 AND 3) 52 4 103 26 167 165 39 9 361 204 565 PROBLEM PLANTS CRATING C> 3 0 5 17 7 15 0 0 15 32 47

TEAM SURVEYS SUMMARY! ----·------HO, OF TEAH SURVEYS 3 2 6 1 16 a 3 0 28 11 39 LEVEL ACTIONS (2 AND 3) 3 2 6 1 16 a 3 0 28 11 39 PROBLEM .PLANTS CRATING C> 0 0 0 0 0 0 0 0 0 0 0 NO. OF FOLLOW-UP TEAM SURVEYS 0 1 7 0 10 13 () 0 17 14 31 LEVEL ACTIONS (2 AND 3) 0 0 4 0 9 12 0 0 13 12 25 PROBLEM PLANTS 2 0 4 () 13 0 1 0 20 0 20 NO REGISTRATIONS ISSUED CT> 1 0 2 0 5 0 1 0 9 0 9 WATER/ICE SUl'IMARY!

----~------WATER SAMPLES TAKEN 2 1 25 4 31 12 14 9 72 26 99 ICE SAMPLES TAKEN 2 0 23 4 23 14 16 5 64 23 87 PLANTS SAMPLED FOR WATER 2 1 12 3 25 9 4 8 43 21 64 PLANTS SAMPLED FOR ICE 2 0 11 3 20 10 6 3 39 16 55 UNSATISFACTORY WATER SAMPLES 0 0 . 2 1 a 5 3 2 13 8 21 UNSATISFACTORY ICE SAMPLES () () 2 0 4 2 6 3 12 5 17 - 2i -

Manitoba Registered Plants Classification Listing by Zone 1·

r--pi ··-·"-'-··-·--·· ' r ."---..,. ' ./ / I' ,..J_ j <' -) ___/ \ I I .· I .· i

~ .·

(/

·~' I I . I V! I I L.L ·-·- ______J __ ··- .-.J' MANITOBA 1. Zones outline major fishing a re as, transportation and management acti vi ti es. They do not necessarily reflect industry delineation and are subject to change. 2 '.~ REGISTERED PLANTS - MANITOBA

ZONE

Plant Plant aserit toilet resno/ operation months last TS water test ice test ?lant hot number na111e/location t\:J?e i'::!Pe i':!?e JFHAtlJJASOND date date date class water '.:>'::!l!li!ndd ':J!:ll!ll!ldd ':!Ylllllldd

31043 BIG BLACK RIVER COOP A FT 1666-T PA IC HO DR 000 00000 840105 8306141 830614 B y BIG BLACK RIVER L.WINNIPEG

31009 BOOTH FISHERIES CANADA CO.LTD, FT 0612-C FI SH PR 000000000000 811113 830922 A y 1225 PLESSIS ROAD WINNIPEG

31044 DAUPHIN RIVER FISH AGENCY A PT 1660-T PA IC HO 000 00 831220 840126 831220 B N ANAHA BAY L.WINNIPEG

31003 DENBEIGH POINT PACKERS A PO 1617-C PA HO IC 000 OOOIJO 0 820727 B3060B 830608 A y LAKE WINNIPEGOSIS DENBEIGH P

31004 DOCKSIDE FISH PRODUCTS A FT 0683-C PA IC HO DR 000 00 00 0 811222 A y LAKE WINNIPEG GIMLI

31047 DOW BRAD A PT 1624-T PA IC HO 000 0 831220 831221 831221 B y LAKE MANITOBA DELTA

31016 EBDYSTONE FISHERMENS COOP A FT 1619-C DR PA IC HO 000 0 811.207 830118 830118 A y LAKE MANITOBA EDDYSTONE

31049 F.F.M.C. BERENS RIVER A FT 1657-T DR: PA IC HO 00 00 840105 830915 830915 B y LAKE WINNIPEG BERENS R.

31050 F.F.M.C. CATFISH CREEK A FT 1659-T D~: PA IC HO 00 840301 B y LAKE IHNNPEG CATFISH CR

310S1 F.F.M.C. GEORGES ISLAND A FT 1674-T DR PA IC HO 00 840105 8306.14 830614 A y GEORGES ISLAND L.IHNNIPEG

31054 F.F.M.C. SELKIRK A FT 0625-C IC HO 000 0000 0 830919 A y MANITOBA SELKIRK

31001 F.F,M.C. WINNIPEG A FT 1664-C IC PA DR FI 000000000000 811113 830~i11 A y 1199 PLESSIS ROAD FR Cli PR SC WINNIPEG

31048 FAIRFORI! FISH AGENCY A FT 1621-C P~I IC HO 000 0 1321214 840~i09 840308 A y LAKE WINNIPEG FAIRFORD 23

REGISTERED PLANTS - MANITOBA ZONE

Plant Plant asent toilet resno/ oPeration months last TS water test ice test Plant hot n1J111ber na11e/location tYPe tYPe type JFMAMJJASOND date date date class water !:IYl!lllldd Y!:li!lldd Y!:IHdd

31007 FISH SERVICES LTD, FT 1686-C FR PA 000000000000 811113 830510 A y MANITOBA COLD STORAGE WINNIPEG

31115 GOODMtlN'S LANDING PLANT A FT 1604-C DR PA IC HO 00 0 831027 830616 830629 A y GOODMAN'S LANDING L.WPG.

31018 GRAND RAPIDS FISHERMENS COOP A FT 1669-C DR PA IC HO 000 00000 0 830615 830609 830609 A y LAKE WINNIPEG GRAND RPDS

31011 INDEPENDENT FISH co.LTD. FT 0635-C DR SC FI SM 000000000000 810720 830518 A y 941 SHERBROOK AVE. PI PR WINNIPEG

31020 L. HiiNITOBA COOP FISHERIES-OP A FT 1703-C PA IC HO 000 0 840104 830126 B y LAKE MANITOBA OAK POINT

31021 L MANITOBA COOP FISHERIES-SA. A FT 1622-C PA IC HO 000 0 831220 B y LAKE MANITOBA ST.AHBROIS

31023 L. MANITOBA COOP FISHERIES-SL, A IFT 1620-C PA IC HO 000 0 831220 A y LAKE MANITOBA ST.LAURENT

31024 LAKE ST.MARTIN COOP A FT 1699-C PA IC HO 000 0 821214 831220 831220 B y LAKE ST ,HARTIN RESERVE

31019 LAKESIDE FISHERIES A CT 1630-C PA IC HO 000 00 0 830208 830119 830119 A y LAKE WINNIPEGOSIS WPGGSIS,

31025 LOG CABIN PACKERS A PT 1615-C PA IC HO 000 820202 830118 830118 A y LAKE MANITOBA IJOGAR

3102.6 UlNDAR FISHERMENS COOP A FT 1618-C PA IC HO 000 820202 A y LAKE MANITOBA LUNDAR

31088 MATHESON ISLAND COOP -ILDVW. A FT 1671-C DR PA IC HO 000 00 00 0 820929 A y LAKE WINNIPEG ISLANDVIEW

31027 MATHESON ISLAND COOP -PINEDOCK A PO 1668-C DR PA IC HO 00 00 00 820929 y LAKE IJINNIPEG A PINEDOCK 24

REGISTERED PLANTS - MANITOBA

ZONE

Plant Plant asent toilet resno/ operation months last TS water test ice test Plant hot nulliber name/location t'.:IPe t'.:IPe t'.:IPe JFMAMJJASOND date date date chss water :1'.:lliill!dd '.:l:llllllldCi '.:l'.:lll!!lldd

31028 MATKOWSKI PETE -DUCK BAY A FT 1634-C PA IC HO 000 0 811208 83011S1 830119 I\ y LAKE WINNIPEGOSIS DUCK BAY

31029 ~ICHALOT E. A PT 1635-C PA IC HO 000 0 811209 A y MEADOW PORTAGE L.MANITOBI\

31010 NEPTUNES FISHERIES FT 0628-C DR SC FI SM 000000000000 810720 830518 830303 A y 472 DUFFERIN AUE, PR WINNIPEG

31030 NOF:THEND PACKERS A FT 1606-C DR PA IC HO 000 0 0 810723 B3021b 830216 A '( DAWSON BAY L.WPGOSIS

31031 PRINCESS HARBOUR FISH AGENCY A FT 1685-C DR PA IC HO 0 00 820629 A y PRINCESS HARBOUR L.WINNIPEG

31102 ROUTHIER H OR M, A PT 1636-C PA1 IC HO 000 0 831206 840114 831221 B y CRANE RIVER MANITOBA

31034 SIGURDSON FISHERIES A FT 1614-C P~1 IC HO 000 00 00 0 820316 A y LAKE WINNIPEG RIVERTON

31033 SIGURDSON K, A PT 1611-C P~1 HO IC 000 0 0 831206 840110 831221 B y LAKE liANITOBA LONELY LK.

31035 SKOWNAN FISH AGENCY A PO 1633-C P~I IC HO 000 0 811209 B30l1'9 830119 A y WATERHEN LAKE SKOWNAN

31036 SVEINSON &SON A FT 1727-C DR PA HO IC 000 0000000 811222 A y LAKE WINNIPEG GIMLI

31037 TRAVERSE BAY COOP A PO 1705-C Pl\ IC HO 00 00 00 0 8309213 830928 830928 A Y' LAKE ~JINNIPEG TRAVERSE B

31111 WANIPIGOW COOP A FT 1605-C DH PA IC HO 0 00 0 0 831007 s3ona 830928 A y HOLLOW WATER RESERVE L. WPG, --- 25

REGISTERED PLANTS - MANITOBA

ZONE 3

Plant Plant asent toilet resno/ oPeration months last TS water test ice test Plant hot nu1ber na111e/location t!:IPe tYPe tYPe JFHAHJJASOND date date date class water !:l!:IHdd YYll!ldd YY!lli!ldd

33002 F.F.H,C, LEAF RAPIDS A FT 1729-C PA IC HO 00000 830711 830711 830711 A y SOUTH INDIAN LAKE LEAF RAPID

33001 F.F.M.C, LYNN LAKE A FT 1604-C PA IC HO 00 830315 830414 830414 A y MAN LYNN LAKE

33015 F.F,M.C. THE PAS A FT 1644-C PA IC HO 000000000000 810713 830607 830607 A y LA ROSE ST THE PAS

33003 F.F.M.C, WABOWDEN A FT 1704-C PA IC HO 00 00000 0 810714 830621 830621 A '( MAN, WABOIJDEN

33004 MTKOWSKI PETE -KISSEYNEW L, FT 1609-C DR P't IC HO 00 00 810713 830623 830623 A y MANITOBA KISSEYNEW - ~( . -

1 Saskatchewan Registered Plants Classification Listing by Zone ·

J 106 .

SASKATCHE\NAN 1· Zones outline major fishing areas, transportation and management activities. They do not necessarily reflect industry delineation and are subject to change. 27

REGISTERED PLANTS - SASKATCHEWAN ZONE 3

Plant Plant asent toilet resno/ operation Dlonths last TS water test ice test Plant hot nu111ber name/location t1;1Pe t1;1pe t1;1pe JFHAl1JJASOND date date date class water !:l!:llllmdd :l!:llllllldd !:l!:lltlllldd

23043 BIG ISLAND COOP (ILE A LA CROS A FT 0700-C PA IC HO 000000 000 0 830215 8401.10 840110 A y ILE A LA CROSSE SASK.

23015 CANOE LAKE FISHERIES A PO 1688-C PA IC HO 00 830622 83062:2 830622 A y SASK, CANOE LAKE

23034 DORE LAKE FISHERMENS COOP A FT 1608-C PA IC HO 0 00 0 0 830913 8305121 831230 lB y DORE LAKE SASK.

23004 F.F.M.C. LA RONGE A FT 0619-C PA IC CM FI 000000000000 810827 830802 830802 A y SASK, FR PR HO LA RONGE

23017 FISHERIES &OCEANS MOBILE A PO 1732-C PA IC HO 00 811016 831017 831017 A y SASK. VARIOUS

23085 LALOCHE/TURNOR FISHERMENS ASSN A PO 1613-T IC HO PA 000 830913 830913 830913 B y TURNOR LAKE SASK,

23013 NORTHLAND PROCESSORS FT 1731-C SM 000000 830912 a3on1 A y SASK. LA RONGE

23016 OSSEY FISHERHENS COOP(DESCHAHB A PO 0614-C PA IC HO 00000 810826 83(W!S 830915 A y DESCHAMBAULT SASK,

23014 PELICAN NARROWS COOP A PO 0615-C PA IC HO 00000 810826 830927 830927 lB y SASK PELICAN NA

23003 WAITE ANB COMPANY A FT 0634-T PA IC HO 0000000000 0 830913 831230 831230 lB y BUFFALO NARROWS SASK,

23002 WAITE FISHERIES A FT 0631-C PA IC HO 0 0 820723 830i'19 830719 B y SASK, BIG RIVER

23019 WEST BOUNDARY COOP A FT 0672-C DR PA IC HO 0 0 840110 840313 840313 ][I y SASK, BEACONHILL 28

ALBERTA 1· Zones outline major fishing areas, transportation and management activities. They do not necessarily reflect industry delineation and are subject to change. 29

REGISTERED PLANTS - ALBERTA ZONE 3

Plant Plant asent toilet resno/ o?eration months last TS water test ice test Plant i1ot nu111ber na111e/location hi?e t':l?e t':l?e JFMAMJJASOND date date date clsss water ':l':lllillldd ':l':llllllJdd ':l':llllll!dd

13002 BILLINGSGATE FISH CO LTD FT 0601-C SM FI FR PR 000000000000 810408 A y 630-7TH AVE S.E. CALGARY

13004 COLD LAKE FISHERMENS COOP A FT 0665-C DR PA IC HO 0 000 810923 !330324 830324 A y ALBERTA COLD LAKE

13008 F.F.M,C. BROOKS A FT 0668-C PA HO IC DR 840315 840315 840315 A y 1~LBERTA BROOKS

13001 F.F.M.C, EDMONTON A FT 1602-C P~1 HO IC PR 000000000000 810921 A y 11635-145TH STREET EDMONTON l.3007 HIGH ARCTIC MARKETING CORP. FT 1637-C PR 0000000 000 840215 840314 A y WETASKWIN ALBERTA

13003 JOF:GEN LARSEN PT 1733-C DR PA IC HO 00 0 810924 A y ALBERTA TILLEY

13006 LAC LA BICHE FISHERHEHS COOP A FT 0677-C DR PA IC HO 00 000 0000 840201 831CI04 831004 A y LAC LA BICHE ALBERTA

13005 NORTHWESTERN FISHING COOP A FT 1658-C PA IC HO 000 00 000 840131 830~109 830309 A y ALBERTA FAUST

REGISTERED PLANTS - ALBERTA ZONE 2 rlant Plant a9ent toilet resno/ u?eration 111onths last TS water test ice test Plant hot number nalfte/location t':!Pe t!:l?e t\l?e JFHAMJJASOHD date date date class water ':l~IH1dd ':l':lllllldd !:l!:l!Hldd

12004 WEST END PACKERS t PRODUCERS A PO 1728-T DR PA IC HO o a40131 a3o:rn9 B y ALBERTA JOUSSARD -,-

N.W.T. Registered Plants Classification Ll~l

,. I ' , c.t. ' 0 I ' , , ' ,' , I , , ! I ;~ , . ·1 ~., , , , , { ~q~ \ ( ~1~ ' l\\ .. '" " ! ~~.. ' ' '·, 2 ·. .. \ ~~1, " " ... . ·, .. .. ' I Ill I 'O.'\:J ~~ •, ~ \_,-~ 8 ? rJ Q Zones outline major fis'tti-ng I ~ ,,.l areas, transportation and m~ageme..!lt j' activities. They do not necessarily·reflect industry delineation and are subject to change·.------______

*'" = "'-=="" ""' ~---~- --~-----~ -~~---- 31

REGISTERED PLANTS - N.W.T.

ZONE

Plant Plant asent toilet resno/ operation months last TS water test ice test Plant h1Jt ri•Jl!lber na111e/location t!:IF-e t!:lf'e t'!:IPe JFMAHJJASOND date clat1: date class wai~er !:l!:llilllldd !:l!:lllll!ldd !:l!:lll!llldd

51001 F.F.H,C. HAY RIVER A FT 1697-C PA IC HO PR 000000000 00 810805 830808 830808 A y GREAT SLAVE LAKE HAY RIVEF:

51002 F,F,H.C, SIMPSON ISLANDS A PO Oo81-C PA re HO 00 0 830825 B y SIMPSON ISLANDS GT.SLAVE l

51003 F.F.H.C, WOOL BAY A PO 1628-C PA IC HO 000 830825 830823 830823 A y GREAT SLAVE LAKE WOOL BAY 32

REGISTERED PLANTS - N.w.r.

ZONE 3

Plant Plant a!:'!ent toilet re!:'!rao/ oPeratfora 111oraths last TS water test ice test Plant hot nurab1!r na111e/location type l':!Pe lYt>e JFHAHJJASOND date date date class water ':l':IRlll!dd ':l':llill!ldd ':l':llllll!dd

53001l ULU FOODS A PT 1646-T DR PA FR 00 820729 930804 830804 B y N.W.T, INUIJIK 33

REGISTERED PLANTS - N.W.T.

ZONE 4

Plant Plant asent toilet resno/ oPeration lllonths last TS water test ice test Plant hot nu111ber nal!le/location tYPe tYPe tYPe JFHAHJJASOND date date date class water YYl!ll!ldd YYl!lllldd YYl!lllldd

54001 ILKALU PLANT A FT 1640-C PA HO FR 00 830823 830824 830824 B y CAMBRIDGE BAY N.W,T, 34

REGISTERED PLANTS -· N.bl.T,

ZONE 8

Plant Plant ·asent toilet resno/ operation months last TS water test ice test Plant hot nu111ber name/location tYPe type tYPe JFKAHJJASOND date date date class water YYlllmdd YYlllllldd YYllll!ldd

58001 ISSATIK COOP A FT 0651-C DR PA FR 00 810811 830826 830826 A y RANKIN INLET HUDSON BAY - 35 -

1) Unregistered Plants A large number of locations exist in the Western Region where fish is either packed, dressed, iced, and/or held awaiting transportation to registered fish packing or processing plants. A large number of these locations can be considered to be small-volume operations located in isolated areas not accessible by standard transportation on a regular basis. Such operations have been previously identified as "lakeside packers", "open-air sites", or "lakeside assemblies". The concerns with these types of operations are: - lack of adequate dressing (where applicable) and holding areas, - lack of approved sanitary procedures, - fish remain unprocessed and unprotected while awaiting irregular transportation. The result is that there is no provision for quality control at these lakeside locations. Since the maintenance of high quality products commences with harvesting and proceeds through to handling, packing/processing and storage, it is necessary that all lakeside locations be surveyed to determine operating conditions. Every lakeside facility should be inspected by the local officer at least once every year using the Fi sh Plant Report (Figure 2) and every "open air site" as prescribed by Q.I.P. landing site surveys. Unregistered plant classification listing (Table 2) will be used to assist field inspection officers in monitoring all such facilities. The department should work towards continually improving such pl ant facilities and operating procedures. - 36 -

1) Unregistered Plants Classification Criteria The procedures to be followed in determining facility classifications are as follows: Classification A Information from previous plant inspection report data indicates no major and few minor deficiencies which can be corrected within 30 days and which do not create unsafe conditions for product or personnel. There are no structural or construction faults and there are no outstanding deficiencies which have not been rectified in past mutually agree upon dates of correction. Plants in this classification should be inspected for deficiencies, using plant inspection forms, at least once per year and follow--up insPections are required on a continuous basis. Such plants can be considered to be one step removed from meeting registration requirements and products from such plants can be considered to be processed in a safe and sanitary environment. Classification B Plants in this classification have major and numerous and extensive minor deficiencies. Major deficiencies which are present may lead to product contamination. There are no structural faults. There may be outstanding deficiencies which have not been rectified past mutually agreed upon dates for correction, but which do not contribute to product contamination. Plants in this classification should be inspected, for deficiencies, using plant inspection forms, at least twice per year and follow-up inspections are required on a continuous basis. - 37 -

Such plants are considered suitable for processing products intended for the export market only if plant management has attempted to correct deficiencies and any delays in doing so are beyond management control, and in the opinion of the local officer, fish ca.n be produced in a safe and sanHary processing environment. Normally such plants should not be permitted to maintain a "B" classification past the year in which it was designated. "B" classification should be maintained only on a seasonal basis so as to promote correction of deficiencies during off-season periods. Classification C

Plants in this classificatfon have ma~jor and minor deficiencies which create unsafe conditions for product and personnel. Extensive work is required over extended periods of time and/or complete facility replacement has been recommended. There may be structural or construction faults which would be incompatible with requirements of other federal or provincial agencies. Such plants are not considered suitable for processing products intended for the export market and termination of plant operation may be initiated through provincial Fisheries personnel, following consultation with Regional Headquarters. Proposed Establishment Rating System (National) At the October/82 National Inspection Policy Committee meeting in Ottawa it was decided that the proposed plant rating system which had undergone two test phases and a third, revised rating form will undergo some additional testing in the field. - 38 -

The system to date incorporates four catagory ratings for registered plants, (A,B,C, or D) depending on the number of deficiencies of each of the four deficiency catagories (minor, major, serious and critical) present after the survey. The system should be in place by June, 1984. (!j z: ...... 1- ...... (/') _J z: 0 ...... l­ e::( u ...... LL...... (/') (/') c::( _J u

(/') 1- z: c::( _J 0... Cl w 0::: w 1- (/')...... (!j w 0::: z: :::::>

N w _J co c:( I- UNREGISTERED FISH PROCESSING PLANTS

CLASSIFICATION A B c

MANITOBA 43 118 66

SASKATCHEWAN 0 47 57

ALBERTA 0 2 0

N.W. T. 3 16 7 - 39 -

1 Manitoba Unregistered Plants Classification Listing by Zone · r-··g; ·--- ...... -·-- ··-··

I \~\

, ~'! I I .· / : I I .· / ~ ~ ~;;..: 7 ~, / I / ( ' I

l.L . __ ...______j ___ ·- __ .J• MANITOBA 1· Zones outline major fishing areas, transportation and management activities. They do not necessarily reflect industry delineation and are subject to change. 40 UNREGISTERED PLANTS - MANITOBA ZONE

Plant Plant agent operation months last TS water test ice test Plant number name/location t'.:lPe JFKAHJJASOND date date date class '.:l'.:llll!ldd ':1'.:ll!l!ldd '.:l'.:llllll!dd

31038 ALBERTSON A. DR PA HO B MANITOBA ARNES

31039 ?iNDERSON C. DR PA B FAIRFORD MAN. FAIRFORD

31040 ANDERSON D. PA HO 0 0 B VICTORIA BCH. L.WHINIPEG 31041 ATEAH J, DR PA HO c VICTORIA BEACH L.WPG, VICTORIA B

31042 BEAR A, PA HO 00 c MANITOBA RED RIVER

31046 DAVHI L. DR PA IC HO 00 B VICTORIA BEACH-L,WPG, VICTORIA B

31045 DAVID.F DR PA IC HO 000 00 00 B L.WPG, VICTORIA BCH. IJICTORIA B

31006 EASTERVILLE FISHERKENS COOP A DR PA IC HO 000 0 821210 830119 830119 B CEIIAR LAKE EASTERVILL

31125 EYJOLFSON OLE DR PA IC HIO A TRAVERSE BAY L.WPG.

31017 F.F.M.C. FROG BAY A DR PA IC HO 820929 A LAKE WINNIPEG FROG BAY

31053 F.F.M.C. MC BETH A DR PA IC ~10 810915 830913 830913 B MC BETH POINT L, tilINNIPEG

31055 F.F.M.C, WARRENS LANDING A PA IC HO IIR 00 830616 830628 830628 B WARREN'S LANDING L.WINNIPEG

31056 GOODMAN M. DR PA IC HO 000 00 B LAKEWINNIPEG GHILI 41 UNREGISTERED PLANTS - MANITOBA

ZONE 1

Plant Plant asent oF>eration !llonths last TS water test ice test Plant number na111e/location tY?e JFMAMJJASOND date date date class YYl111!1dd YYll'lt!!dd YYl!lllldd

31057 GREEN E, DR PA IC HO B BELAIR L.WPG. BELAIR 31058 HALGREN T. DR PA IC HO 000 00 0 A VICTORIA BEACH L.!JINNIPEG 31059 HAHF'TON C, DR PA HO IC 0 c VICTORIA BEACH L.WINIHPEG

31060 HOLii A. DR PA IC HO 000 00 0 0 B LAKE WINNIPEG GH!LI

31061 HOURIE A. DR PA IC HO 000 00 00 0 A PATRICir~ BEACH L.WINNIPEG

31062 IRVINE Q, DR PA IC HO 000 00 00 0 A GRAND MARAIS LWIMNIPEG

31063 IRVINE w. DR PA IC HO 0 00 0 c GRAND MARAIS L.IHNNIPEG

31064 ISFELD A. DR PA IC HO 000 00 0 A LAKE WINNIPEG GH!LI

31065 ISFELD C.E. PA IC HO 0 B WINNIPEG BEACH L.WINNIPEG

31066 ISFELD DOUG DR PA HO IC 00 00 0 B WINNIPEG BEACH L.WINNIPEG

31067 ISFELD EDWARD DR PA IC HO 0 B WINNIPEG BEACH L.WINNIPEG

31068 ISFELO G. DR PA IC HO 0 0 c WPG. BEACH L. WPG, IJPG.BEACH

31069 ISFELD GUS PA IC DR HO 0 0 B SANDY HOOK L.WPG, SANDY HOOK 42 UNREGISTERED PLANTS - HANITOBA ZONE

Plant Plant asent operation months last TS ~rater test ice test ? lant number name/location tsPe JFKAKJJASOND date date date class ':l!:lll!l!1dd ':l':llllllldd ':1':11H1dd 31070 ISFELD F'. DR PA HO IC B L.lil INN IPEG WPG.BEACH

31071 lSFELD R. DR PA HO IC 0 B LAKE WINNIPEG ldPG.BEACH

31072 JACKHEAD BAND FISH AGENCY DR PA HO IC 00 B LAKE WINNIPEG J1'.\CKHEAD 31073 JACOBSON B. DR PA IC HO c LAKE WINNIPEG GIMLI

31074 JACOBSON J, DR PA IC HO B LAKE WINNIPEG-GIKLI GIIU

31077 JOESEPH C. DR PA IC HO 00 00 00 A LAKE WINNIPEG VICTORIA B

31075 JOHNSON B,R. DR PA IC HO 0 B MANITOBA ASHERN

31076 JOHNSON nR DR PA IC HO 00 B L.WPG VICTORIA BCH. VICTORIA B

31121 JOHNSON S. PA IC HO 0 B LAKE WINNIPEG GIMLI

31120 JONSSON R. PA IC HO 0 B VICTORIA BEACH L.lr!INNIF'EG

31078 KJARTANSON BEN DR PA IC HO 00 0 B LAKE WINNIPEG HECLA IS,

31079 KJARTANSON J,R,-AlfARANTH A f'A IC HO 000 0 0 831221 831221 8:31221 B LAKE ttANITOBA AMARANTH

31080 KJAF:T ANSON J. R, -LANGRUTH A PA IC HO 000 0 B LAKE MANITOBA LANGRUTH 43 UNREGISTERED PLANTS - MANITOBA

ZONE 1

?lant Plant asent oi>eration 111onths last TS water test ice test ?lant n1J111be ~ na111e/location t!:l?P. JFKAHJJASOND date date date class !:l!:lllllildd !:l:llllllldd !:l!:lllll!ldd

31081 KLATT C, DR f'A IC HO 000 00 00 0 B LAKE WINNIPEG HILLSIDE B

31117 KNOTT , W. PA HO IC B BEACONIA LWP15.

31123 KNOTT W. IC HO P~1 0 B LAKE WINNIPEG BEACON IA

31082 KOOSTATAK FISHERIES LTD.-JCKD DR PA IC HO 0 810914 c LAKE WINIHPEG JACKHEAD I

31083 KOOSTATAK FISHERIES LTD.-KOOST PA DR IC HO 0 820930 B LAKE WINllIPEG KOOSTATA~:

31084 KRISTIANSON R. DR PA IC HO A LAKE WINtHPEG GHiLI

31085 KROKEN N. DR PA IC HO 00 0 B VICTORIA BEACH -L.WF'G, 1JICTORIA B

31086 LEFTROOK BILL DR PA IC HO 0 B LAKE WINNIPEG RED RIVER

31052 MAGNUSSON G,G, DR PA IC HO 0 801002 A LAKE WINNIPEG MAGNUSVILL

31087 MAGNUSSON J, - HNAUSA DR PA IC: HO 0 B LAKE WINNIPEG HNAUSA

31089 MONKMAN ED DR PA IC HO 0 B LOON STRAITS MANITOBA

31090 MONKMAN H. DR PA IC HO 000 00 0 A VICTORIA B, L.WPG. VICTORIA B

31091 MONK!IAN R. DR PA IC HO 0 0 B LAKE IHNNIPEG VICTORIA B 44 UNREGISTERED PLANTS - HAIHTOBA ZONE

Plant Plant asent operation 111onths last TS water test ice test Plant number name/location t!:l?e JFHAHJJASOND date date date class YYlllllldd YYITl!lldd YYllil!ldd 31092 MONSON &SINCLAIR DR PA IC HO 0 0 c LAKE WINNIPEG BiiLSAM BAY

31093 MONSON B, DR PA IC HO 000 00 0 B LAKE WINNIPEG VICTORHI B

31094 MOOSE LAKE FISHERMEHS ASS'H WH A PA IC HO 00 B WILLIAM LAKE MANIITOBA

31095 NORWAY HOUSE FISHERHENS A.TI A DR PA IC HIJ 00 830615 830614 B PLAYGREEN LAKE TAIT ISLAN

31096 OLAFSON O. DR PA IC HO 000 00 0 B VICTORIA BEACH L,Wf'G.

31097 OLAFSON T. DR f'A IC HO 000 00 00 0 A VICTORIA BEACH L.WPG.

31098 PATZER B. DR PA IC HO 000 00 0 A LAKE WINNIPEG BEACON IA

31099 PATZER C DR f'A IC HO 000 00 0 0 A BEACONIA L. lflNNIPEG

31100 F'ORAYKO J DR f'A IC 000 00 00 0 A BALSAM BAY HO L.WPG.

31101 ROLLING RIVER RESERVE DR PA IC HO B MANITOBA ERICKSON

31032 SIGURDSON &DZYDZ A DR PA IC HO 00 820929 B LAKE WINNIPEG ARNES 31103 SIGURGIERSON B, DR PA IC HO 00 00 0 c LAKE WINNIPEG HECLA I,

31104 SIMARD ED DR PA IC HO 00 0 0 c MANIGOTOGAN L.IJPG, 45 UNREGISTERED PLANTS - MANITOBA ZONE

Plant Plant asent o?eration months last TS water test ice test Plant nu111ber na111e/location t!:I?~~ JFHAMJJASOND date date date class \:1Ylll1!1dd YYllll!!dd !:lYHdd

31105 SINCLAIR M. DR p,~ IC 00 00 0 0 A LAKE WINNIPEG HO BEACONIA

31106 SMITH R. DR PA IC HO 00 0 A LAKE WINNIPEG GHILI

31122 SOLMINSOr! R. PA IC HO 0 B LAKE WINNIPEG GIMLI

31107 SWAIN M. DR P't IC 000 00 0 ti LAKE WINNIPEG HO BELAIR

31116 THOMAS , GLENN PA IC HO A BEACON IA L. WPG.

31124 THOMAS H, f'A IC HCI 0 A LAKE WINNIPEG BEACON IA

31108 VALGAF:DSON D, IIR PA IC HO B FROG BAY L.WINIHPEG

31109 VISNl\UGH O, DR f'A IC HO 000 00 0 0 A PATRICiiA BEACH L.WF'G,

31110 VISNAUGH W. DR f'A IC HO 000 00 00 0 A PATRICIA BEACH L.WPG.

31113 WANCHALUK N, DR PA IC HO 00 00 00 0 A GRAND MARAIS L.WPG.

31112 WINIUPEGOSIS FISHERMENS CP-G.H A DR PA IC HO 00 831206 830719 830719 B GOOD HARBOUR L.bJPGOSIS

31114 ZEBRUN A. DR f'A IC HO B LAKE WINNIPEG BELAIR 46 UNREGISTERED PLANTS - HANITOM

ZONE 2

Plant Plant asent oi>eration months last TS water test ice test Plant number na111e/location ht?e JFMAHJJASOND date date date class !:l!:lllll!ldd !!!!lllllldd !!!:llllllldd 32001 BLAND J,-WAR LAKE IC HO c WAR LAKE MANITOBA 32006 F.F.M.C, SAVAGE I, ANGLING LAK HO IC c ANGLING LAKE MANITOBA

32004 F.F.tt.C. SAVAGE I. BEGG L. IC HO B BEGG LAKE MANITOBA

32007 F.F,H.C. SAVAGE I. BIGSTONE L, IC HIJ B BIGSTONE L{IKE MAN IT OM

32008 F.F.H.C, SAVAGE I. E{IST LAKE IC HO c EAST LAKE MANITOM

32009 F,F,H.C, S{IVAGE I, EDMUND L, IC HO 0 c EDMUND LAKE MANITOBA

32010 F.F.H.C. SAVAGE I, GOOSE LAKE HO IC 00 B GOOSE LAKE MANITOBA

32011 F.F,M.C. SAVAGE I. HAYWARD L. HO IC B HAYWARD L{IKE MANITOBA

32005 F.F.H.C, S{IVAGE I, JOINT LAKE IC HO B JOINT LAKE MANITOBA 32012 F.F.M.C, SAVAGE I. KALIECAHOOL IC HO c KALIECAHOOLIE LAKE MANITOBA

32013 F.F.M,C. SAVAGE I, KISTAGAN I, IC HO B KISTAGAN LAKE MANITOBA 32014 F.F.M,C. SAVAGE I, KNIFE L, IC HO c KNIFE LAKE MANITOBA 32016 F.F,M.C. SAVAGE I, RORKE L, IC HO c RORKE LAKE MANITOBA 47

UNREGISTERED PLANTS - MANITOBA

ZONE 2

Plant Plant asent operation months last TS water test ice test Plant number name/location t~P1e JFMAHJJASotW date date date class ~~m111dd ~~lllllldd ~~l'l!llldd

32018 F.F.M.C. SAVAGE I. SEMMENS L. IC HO c SEMMENS LAKE HAN IT OBA

32002 F.F.M.C. SAVAGE ISLAND f'A IC HO FR 790627 c ISLAND L1~KE FI CM SAVAGE IS,

32019 GARDENHILL FISHERMEN IC HO 00 B BEAVERHILL LAKE MANITOBA

32003 GOD'S LAKE FISHERMEN IC HO 00 B SHARP LAKE MANITOBA

32020 GOD'S LAKE NARROWS BAND -GODS PA IC HO B GOD'S NARROWS GOD'S LAKE

32021 GOD'S LAKE NARROWS BAND -TCHWD IC HO c TOUCHWOOD LAKE MANITOBA

32022 GOD'S RIVER AGENCY A IC HO 00 830317 c GOD'S LAKE GODS RIVER 32023 ILFORD FISHERMEN WHITEFISH L, IC HO c WHITEFISH LAKE MANITOBA

32017 ISLAND LAKE FISHERMEN IC HO 00 B ISLAND UIKE ST. Tl4ERESE

32024 ISLAND LAKE FISHERMEN IC HO 0 B ISLAND LAKE MANITOBA

32025 OXFORD HOUSE FISHERliEN -KNEE L IC HO 0 0 Ii KNEE LAKE MANITOBA

32026 OXFORD HOUSE FISHERMEN -OXFD L IC HO 0 c OXFORD LAKE MANITOBA

32027 OXFORD HOUSE FISHERllEN -RAT L. HO IC 0 c RAT LAKE MANITOBA 48 UNREGISTERED PLANTS - MANITOBA ZONE 2

Plant Plant asent operation 111onths last TS t~ater test ice test Plant nu111ber name/location t':lPe JFHAMJJASOND date date date class ':l':llllllldd Y':lllillldd ':l':llllllldd

32028 PAPANAKIS J.&T. -LTL.BOLTON IC HO B LITTLE BOLTON LAKE MANITOBA 32029 PAPANAKIS J,- MOLSON L, IC HO c MOLSON LAKE MANITOBA

32033 RED SUCKER LAKE FISHERKEN PIRC IC HO 00 B PIERCE LAKE ONTARIO

32015 RED SUCKER LAKE FISHERMEN R,S, IC HO 0 00 B RED SUCKER LAKE MANITOBA

32034 RED SUCKER LAKE FISHERMEN STUL IC HO 00 c STULL LAKE ONTARIO 32030 SKULKOSKI W. -ASWAPISWANAN L. PA HO IC c ASWAPISWANAN LAKE MANITOBA 32031 ST.THERESE FISHERMEN IC HO 00 c ISLAND LAKE MANITOBA 32032 WASSAGAMAK FISHERMEN -STVNSN L IC HO c STEVENSON LAKE MANITOBA 49

UNREGISTERED PLANTS - Ht!NITOBA ZONE 3

Plant Plant asent operation months last TS water test ice test Plant n1Jmber na111e/locatiori tYPe JFMAHJJASOND date date date class \:l\:lllJl!Jdd \:l\:lllll!idd Y!:!lllllldd

33005 ANDERSON W. IC HO B RUSTY LAKE MANITOBA

33006 BAKER D. IC HO B SUWANEE LAKE MANITOBA

33120 BAKER S, BARRINGTON IC HO 0 A BARRINGTON LAKE MANITOBA

33007 BALL1~NTYNE A. IC HO 00 00 00 A SASKATCHEWAN RIVER MANITOBA

33008 BARTLETT R. -HERBLET L. IC HO 0 B HERBLET LAKE MANITOBA

33009 BARTLETT F:, -WEKUSKO/HERB L. HO IC 0 0 B WEKUSKO LAKE BERRY BAY

33010 BATES SAH IC HO 0 B GOOSE LAKE HAN IT OBA

33012 BIGHETTY PASCAL -SISIF'.UK L. IC HO 0 B SISIF'UK LAKE iiANITOBA

33013 BIGHETTY PHILIP IC HO 0 B MC KNIGHT LPIKE MANITOBA

33011 BLANB J. -ATKINSON L. IC HCI 0 0 B ATKINSON LAKE MANITOBA

33014 BROCHET FISHERMEN'S COOP IC HO PA 00 B BOUNDARY ISLAND REI'NDEER L

33017 CHARTRAND H. W.RABBIT L. IC HO 0 B WHITE RABBIT LAKE MANITOBA

33016 CHARTRAND H, HALFWAY IC HO c HALFWAY LAKE MANITOBA 50

UNREGISTERED PLANTS - MANITOBA

ZONE 3

Flant Plant asent operation 111onths last TS water test ice test Plant number name/location tY?e JFMAMJJASOND date date date class ':!!:ll!ll!ldd !:l':!lllllldd !:l!:!Oll!ldd

33018 CHEBOYER H. IC HO 0 B NATAWAHUNAN LAKE MANITOBA 33019 CHRAPUN M.-BATTY L. IC HO c BATTY LAKE MANITOBA

33020 CHRAPUN M.-BURNTWOOD L, IC HO 0 0 c BURNTWOOD LAKE MAN IT OM

33021 CHF:APUN M. -KIPIHAGAN L, PA IC HO 0 c KIPAHAGAN LAKE MANITOBA

33022 CHRAPUN M.-LIMESTONE PT.L, PA IC HO 0 0 c LIMESTONE POINT LAKE MANITOBA

33023 CLEE M.-N.INDIAN L. IC HO 0 0 0 c NORTH INDIAN LAKE MANITOBA

33024 CORDELL W.R. -PARTRIDGE CROP IC HO 0 B PARTRIDGE CROP LAKE MANITOBA

33025 CORDELL W.R. -WITCHAI LAKE IC HO 00 0 A WITCHAI LAKE MANITOBA 33026 CORMAN A. IC HO c lJOOSEY LAKE MANITOBA

33027 CORMAN J, PA IC HO 0 D A WEKUSKO LAKE MANITOBA

33028 CROSS LAKE FISHERMENS ASS'N PA IC HO D 0 B WALKER LAKE MMHTOBA

33113 CROSS LAKE FISHERHENS ASS'N PS PA HO 0 c F'IPESTONE LAKE MANITOBA

33029 DRAM C, -CARROT RIVER IC HO lB CARROT RIVER MANITOBA 51

UNREGISTERED PLANTS - MANITOBA ZONE 3 r'l.cnt Plant asent oi>eration months last TS water test ice test Plant n1Jmber name/location l!:!J>e JFMAHJJASOND date date date class !:l!:llllllldd !:l!:lllillldd !:l!:lllJ!lldd

33030 DRAM C. -DRUNKEN LAKE IC HO 0 0 c DRUNKEN LAKE . MANITOBA

33031 DRAM cI -KISKITTO U~KE IC HO B KISKHTO LAKE MANITOBA

33032 DRArl C. -KISKITTOGISU LAKE PA IC HO 0000 A KISKITTOGISU LAKE MANITOBA

33034 DRAM C. -SOLOMON LAKE IC HO 00 c SOLOllON LAKE MANITOBA

3311B DRMl C. -WHITE RABBIT LAKE IC HO 0 A WHITE RABBIT MANITOBA 33035 f!UCHARME L. IC HO c WEKUSKO LAKE MANITOBA

33036 DYSART M.-ENATIC L. IC HO 0 B ENATIC LAKE MANITOBA

33037 DYSART S. IC HO 00 0 c MYNARSKI LAKE HAN ITO BA

33039 DYSA~:T li. -BUCKLAND LAKE IC HO B BUCKLAND LAKE MANITOBA

33038 DYSA~:T W. -LECLP,IR LAKE IC HO B LECLAIR LAKE MANITOBA

33044 F.F.M.C. ODEI R. A PA IC HO 0000 330712 830712 830712 B ODEI RIVER MANITOBA

33112 FLEMMING J, IC HO B SISSIPUK LAKE MANITOBA 33041 FORTON T. -GAUER IC HO c GAUER LAKE liANITOBA 52 UNREGISTERED PLANTS - MANITOBA

ZONE 3

Plant Plant asent oi>eration months last TS water test ice test Plant number na111e/location t\!Pe JFHAltJJASOND date date date class Y!:llllllldd !:l!:lillllldd ':!':!l!lllldd 33040 FORTON T. -MELVIN L, IC HO B MELVIN LAKE MANITOBA

33042 FORTON T. -WOOD IC HO B WOOD LAKE MANITOBA

33043 FF:f1NCOIS L. IC HO 0 0 c LEFTROOK LAKE MANITOBA

33045 GRANVILLE LAKE FISHERMENS ASSN PA IC HO B PICKEREL NARROWS GRANVILLE 33046 GRIEVES A. IC HO c UTIK LAKE MANITOBA

33121 GRIEVES A. -BEAR IC HO 0 A BEAR LAKE MANITOBA 33048 HRECHKA T. IC HO c KAMUCHAWIE LAKE MANITOBA

33050 HRECHKA W. -DUNSHEATH LAKE IC HO 00 B DUNSHEATH LAKE MANITOBA

33051 HRECHKA W, -ELDON LAKE IC HO B ELDON LAKE LYNN L. 33052 HRECHKA W. -LAURIE LAKE IC HO c LAURIE LAKE MANITOBA

33053 HRECHKA W. -SIMPSON LAKE IC HO B SIMPSON LAKE MANITOBA

33054 HRECHKA W. -WELLS LAKE IC HO 0 A WELLS LAKE MANITOBA

33055 ILFORD FISHERMENS A. ATKINSON IC HO 0 B ATKINSON LAKE MANITOBA 53 UNREGISTERED PLANTS - MANITOBA ZONE 3

Fl;::rit Plant asent o?eration months last TS water test ice test Plant number name/location t~Pe JFHAMJJASOND date date date class YYR111ldd YYl!il!ldd YYlllllidd

33056 ILFORD FISHERMENS A. CUDDLE l. IC HO 00 B CUDDLE LAKE MANITOBA

33058 ILFO:~D FISHERMENS A, ILFORD IC HO 740804 B MANITOBA IL FORD

33059 ILFORD FISHERMENS A, SILSBY L. IC HO 0000 A SILSBY LAKE MANITOBA 33060 ILFOHD FISHERMENS A. IJASKAHJAK IC HO c WASKAIWAllA LAKE MANITOBA

33057 ILFORD FISHERNENS A, HIGHILL L IC HO 0 c HIGHHILL LAKE tlANITOBA

33062 JONASSON ALEX -CAUCHON IC HO 0 0000 A CAUCHON LAKE MANITOBA

33063 JONASSON ALEX -COTTON IC HO 0 0 A COTTON LAKE MANITOBA

33064 JONASSON ALEX -N.INDIAN IC HO 0 B NORTH INDIAN LAKE MANITOBA

33065 JONASSON ALEX -UTIK IC HO 0 0 c UTIK LAKE HAN IT OBA

33066 JON~1SSON&:ARMSTRONG -GOULET L, IC HO 0 0 B GOULET L~1KE MANITOBA

33067 LAC BROCHET FISHERHENS ASS'N IC HO B LAC BROCHET MANITOBA

33068 LAMIRONDE M.-ARHSTRONG L. IC HO 0 B ARMSTRONG LAKE MANITOBA

33070 LAPONSE D, IC HO 00 B OOSTITI!\ LAKE MANITOBA 54

UNREGISTERED PLANTS - MANITOBA

ZONE 3

P limt Plant asent o?eration 11onths last TS water test ice test Plant number name/location t!:l?e JFHAMJJASOND date date date class !:l!:l!llllldd !:IYllllTldd !:l!:llllllldd

33069 LATHLIN R. IC HO 00 00 0 A SASKATCHEWAN RIVER MMIITOBA

33071 LAVALLEE W. -SASK. R. IC HO 00 00 0 A SASKATCHEWAN RIVER MANITOBA

33122 MIHKOWSKI PETE - GUTH, HO IC 0 A GUTHRIE LAKE MANITOBA 33072 MCKAY M.-CUDDLE L. IC HO c CUDDLE LAKE MANITOBA

33073 MERASTY J. IC HO B HJALMARSON LAKE MANITOBA

33074 MERASTY L. -EASTON LAKE IC HO B EASTON LAKE MAH IT OM

33075 MERASTY L. -ENATIC LAKE IC HO 0 B ENf'1TIC LAKE MANITOBA

33076 MERASTY L. -EYRIE LAKE IC HO B EYRIE LAKE MANITOBA

33117 MOOSE J, MACKARRACHER IC HO 0 0 c MACARRACHER LAKE MANITOBA

33077 MOOSE LAKE FISHERMENS ASS'N ML A PA IC HO 00 00000 0 830714 830910 840302 B MOOSE LAKE-HAN. MOOSE LAKE

33078 NELSON HOUSE FISHERMEN -BLDK.L IC HO 0 0 c BALDOCK LAKE MANITOBA

33079 NELSON HOUSE FISHERMEN -GAUER IC HO 0 00 B GAUER LAKE MANITOBA

33080 NELSON HOUSE FISHERMEN -LFTRK, IC HO 00 c LEFTROOK LAKE r'\ANITOBA 55

UNREGISTERED PLANTS - MANITOBA

ZONE 3 pl iJl1t Plant asent oi>eration 11onths last TS water test ice test Plant nuR1be1' name/location t~i>e JFMAMJJASOND date date date class ~~mmdd YYllll!!dd Y~n111tdd

33081 NELSON HOUSE FISHERMEN -MYNARS IC HO 0 0 B HYNARSKI LAKE MANITOBA

33082 NELSON HOUSE FISHERMEN -NOTIGI IC HO c NOTIGI L~1KE HANH OM

33083 NELSON HOUSE FISHERMEN -RAT L. IC HO B RAT LAKE WEST MANITOBA 33084 NELSON HOUSE FISHERMEN -1.JAPISU IC HO c WAPISU L~.KE M1~NITOBA

33085 NELSON HOUSE FISHERMEN -WSKWM, IC HO 0 B WUSKWATIM LAKE MANITOBA

33086 NORWAY HOUSE FISHERliENS A.PLGP A DR PA IC HO 00 00 830615 830614 830615 A PLAYGREEN POINT MAN IT OP.A

33087 OLSON L. IC HO B MATHESON LAKE MANITOB?1

33088 F'UKATAWAG(lN FSMS ASSN. -BRNTWD IC HO 0 B BURNTWOOD LA~E MANITOM

33114 F'UKATAWAGAN FSMS ASSN. -FLTRCK PA HO 0 c FLATROCK LAKE MANITOBA

33089 F'UKATAWAGAN FSHS ASSN. -HRCK L IC HO 00 B HIGHROCK LAKE MANITOBA

33090 PUl

33061 S.INDIAN LAKE FSHS ASSN. BIGS IC HO 0 00 B BIGSAND LAKE H?1NITOBA

33049 S.INDIAN LAKE FSMS ASSN. BF:GTN IC HO 00 0 00 A BARRINGTON LAKE MANITOBA 56

UNREGISTERED PLANTS - MANITOBA

ZONE 3

Plant Plant asent oPeration months last TS water test ice test Plant number name/location type JFMAHJJASOND date date date class \:l\:lllll!ldd !:l':lllllbdd !:l!:ll!lllldd

33101 S.INDIAN LAKE FSMS ASSN, CAHP3 IC HO 0000 B SOUTH INDIAN LAKE CAMP 3

33102 S.INDIAN LAKE FSMS ASSN. CAMP9 IC HO B SOUTH INDIAN LAKE CMIP 9

33103 S,HIDIAN LAKE FSMS ASSN. LOON IC HO PA 0 B LOON NARROWS

s I I tl+

33104 S.INDIAN LAKE FSMS ASSN. MISSI PA HO IC 0000 A IHSSI FALLS S.LL.

33105 S.INDIAN LAKE FSl'IS ASSN. OPACH IC HO 00 B OPACHUANA LAKE MANITOBA

33091 SANDERSON R. -ATKINSON L, IC HO 00 A ATKINSON LAKE MANITOBA

33092 SANDERSON R. -HIGHILL L. IC HO 0 c HIGH HILL LAKE MANITOBA

33093 SKULMOSKI W. -APEGANAU LAKE HO IC 0 c AF'EGANAU LAKE MANITOBA

33115 SKULMOSKI W, -CROSS PORTAGE HO IC 00 A SIPHIESK LAKE MANITOBA

33096 SKULMOSKI W. -DAFOE LAKE IC HO 0 A DAFOE LAKE MANITOBA

33097 SKULMOSKI W. -DUGAS LAKE IC HO 0 c DUGAS LAKE MANITOBA 33033 SKUUiOSKI W. -LAWFORD re HO c LAWFORD LAKE MANITOBA 33098 SKULMOSKI W. -MAX LAKE IC HO c MAX LAKE MANITOBA 57 UNREGISTERED PLANTS - MANITOBA

ZONE 3

Fl ant Plant asent o?eration months last TS ;iater test ice test Plant number name/location t!:!?I? JFKAMJJASOND date date date class ':l!:!lbllldd !:!!:!lhr!Jdd ':l!:!lllR1dd

33099 SKULMOSKI W. -NELSON R. IC HO A NELSON RIVER MANITOBA

33095 SKULHOSKI IJ, -SIF'IWESK LAKE IC HO 00000 B SIP IWESK LAl\E BULGEF: MY

33100 Sr:IJLMOSK:: W, -STUPART LAKE IC HO 00 c STUPART LAKE MANI10BA

33106 SPENCE &MOOSE IC HO 0 c TORRENCE LAKE MANITOBA

33107 SPLIT LAKE FISHERMENS ASS'N IC HO B SF'LIT LAKE MANITOBA

33108 STOLTZ L. IC HO 0 B WEKUSKO LAKE MANITOBA

33116 TAITE R. HO IC 0 c BIGSAND LAKE MANITOBA

33111 THICKET PORTAGE FISHERMEN -LIIG IC HO 0 B LANDING LAKE (H,PRONTEAUl MANITOBA

33109 THICKET PORTAGE FISHERMEN -T.P IC HO 0 0 0 B THICKET PORTAGE MANITOBA

J3119 THICKET PORTAGE FISHERHEN -WTG IC HO 0 c WillTERING LAKE M?1HITOB1;

33047 THOfiNE J, -NATA!JAHUMAN LAKE IC HO B NAT AWAHUN1~N LAKE MANITOM

33110 THORNE J, -PIKWITONEJ IC HO 0 B F'IKWITONEI MANITOBA 58

UNREGISTERED PLANTS - MANITOBA ZONE plant plant agent operation months last IS water test ice test plant number name/location type JFliAHJJASOND date date date class yymmdd yymmdd yymmdd

60 UNREGISTERED PLANTS - SASKATCHEWAN ., ZONE l..

Plant Plant asent oi>eration 111onths last TS water test ice test i>lant nu111ber na111e/location l!:!?e JFtlAKJJASOND date date date class !:l!:!Hdd !:l!:lllllldd !:l!:!Hdd 22007 HENRY LAKE IC HO c HENRY LAKE SASK. 22010 PELICAN NARROWS COOP-TWO RIVER IC HO c TWO RIVERS/REINDEER LAKE SASK,

22001 REINDEER FISHERKENS COOP-AtlISK IC HO B MIISKIT ISLAND REINDEER L

22012 REINDEER L. FISHERMENS COOP-SI IC HO B SANDY ISLAND SASK.

22005 REINDEER L.FISHERMENS COOP-KIN A DR PA IC HO 00 810826 830817 830817 B COOP POINT REINDEER L

22009 REINDEER L.FISHERMENS COOP-MLT IC HO B MILTON ISLAND SASK.

22011 REINDEER L.FISHERtlENS COOP-S.E PA IC HO B SOUTHEND SASK,

22014 REINDEER LFISHERMENS COOP-WAP IC HO B WAPUS ISLAND SASK.

22008 WOLLASTON L.FISHERMENS COOP-MI IC HO B MOOOSE ISLAND SASK.

22013 WOLLASTON L.FISHERMENS COOP-SI IC HO B SANDY ISLAND SASK,

22015 WOLLASTON LAKE FISHERKENS COOP A PA IC HO 840111 B WOLLASTON LAKE SASK. 61

UNREGISTERED PLANTS - SASKATCHEWAN

'.! ZONE " Plont i>lant asent or-eration 111onths last TS water test ice test Plant nu111be 1r name/location t!lr-e JFtlAMJJASOND date date date class !l!:lllillldd !:1!:11111!1dd !:1!:1111mdd

23105 ACHENNINI LAKE PLANT IC HO c ACHEi~NINI LAKE SASK,

23096 AIRWAY LAKE IC HO c AIRWAY U\KE SASK,

23097 ATTITTI LAKE IC HO c ATTITTI LAKE SASK. 23005 BELCHER LAKE IC HO c BELCHER LAKE SASK.

23007 BIG FLATSTONE IC HO c BIG FLATSTONE SASK. 23011 BIGSTONE LAKE IC HO c BIGSTONE LAKE SASK. 23028 BUFFALO RIVER BAND FISH COOP IC HO c DILLON LAKE SASK.

23104 CHAMBERLAND D, PA IC HQ! 0 B CANDLE U1KE SASK.

23023 CHURCHILL LAKE IC HO B CHURCHILL LAKE SASK.,

23024 CORNEILLE LAKE IC HO 0 c CORNEILLE LAKE SASK,

23025 CREE LAKE IC HO 000 c CREE LAKE SASK.

23021 CROSSLAND, AHIE IC HO B CHITEK LAKE SASK.

23026 CUMBERLAND HOUSE COOP IC HO 0000 830708 830624 B SASKATCHEWAN RIVER SASK. 62

UNREGISTERED PLANTS - SASKATCHEWAN ZONE 3

Plant Plant asent o?eration 111onths last TS water test ice test Plant rn1111ber narne/location h1?e JFMAIUJASOND date date date class YYlhllldd :!Ylllmdd Y:llllll!dd 23079 CUMBERLAND HOUSE FISH COOP-SGI PA IC HO c SUGGI LAKE SASK.

23001 DENARE BEACH FISHERMENS COOP A PA IC HO 810527 B BEAVER LAKE SASK. 23095 DIAGNEAULT F-WHITEFISH RIVER IC HO c LITTLE PETER POND SASK. 23030 DIPPER LAKE IC HO c DIPPER LAKE SASK.

23012 DUF'EEL R, PA IC HO 0 B CANDLE LAKE SASK.

23031 EGG LAKE IC HO B EGG LAKE SASK,

23032 ELAINE LAKE IC HO c ELAINE LAKE SASK. 23033 FORCIER LAKE IC HO c FORCIER LAKE SASK, 23035 FROBISHER LAKE IC HO c FROBISHER LAKE SASK. 23037 GRANITE LAKE IC HO c GRANITE LAKE SASK. 23039 GUILLOUX LAKE IC HO c GUILLOUX LAKE SASK. 23040 HACKETT LAKE IC HO c HACKETT LAKE SfiSK. 23088 HANSON TOM IC HO c WHITEFISH RIVER L.PETER PD 63

UNREGISTERED PLANTS - S'1SKATCHEWAN

ZONE 3

Plant ?lant asent oi>eration 11onths last TS water test ice test ?lant number name/location tYPe JFHAMJJASOND date date date class YYHdd YYl!ll!ldd !:l!:llllllldd

23100 HAYDUKEWICH AND FREEtlONT DR PA IC HO B CMDLE LAKE SASK.

23106 HAYDUKEWICH G&T IC HO 0 B CANDLE U~KE SASK. 23042 HIGHIWAY LAKE IC HO c HIGHWAY LAKE SASK.

23044 JAN L1~KE IC HO c JAN l_AKE SASK. 23045 KAKABIGISH LAKE IC HO c KAKA:BIGISH LflKE SASK, 23047 KELLER LAKE IC HO c KELLER LAKE SASK.

23049 KIF'IHAGAN L1~KE IC HO c KIF'IHAGAN LAKE SASK.

23027 KLASSEN &CHRISTIANSON PA IC HO 0 B DELARONDE L1~KE SASK,,

23046 KNEE LAKE FISHERMEN IC HO 0 00 c KNEE LAKE SASK,

23050 LA LOCHE FISHERMENS ASS'N IC HO B LAC LA LOCHE SASK,

23051 LANDSDOWNE LAKE IC HO c LANDSDOIJNE LAKE SASK,

23058 LARONGE FISHERMENS COOP-MEYlff IC HO MEEYAMOOT BAY B SASK.

23102 LARONGE FISHERMENS COOP-POT.PT PA IC DR HO B POTATO POINT-LACLARONGE SASK, 64

UNREGISTERED PLANTS - SASKATCHEWAN

ZONE 3

Plant Plant asent O?eration aonths last TS water test ice test Plant nu11ber na111e/location t!:IPe JFHAHJJASOND date date date class !:l!:lllillldd !:l!:IDUlldd !:l!:llllll!dd 23053 LISTEN LAKE IC HO c LISTEN LAKE SASKi 23054 LITTLE FLATSTONE LAKE IC HO c LITTLE FLATSTONE LAKE SASK, 23055 LLOYD LAKE IC HO c LLOYD LAKE SASK.

23056 LOVELL LAKE IC HO 0 c LOVELL LAKE SASK.

23109 LOZEJ A, IC HO 0 B CANDLE LAKE SASK,

23057 MANAWAN LAKE • IC HO 0 B MANAWAN LAKE SASK,

23107 MARCHAND F. IC HO 0 B CANDLE LAKE SASK, 23063 NATAWEUSE LAKE IC HO c NATAWEUSE LAKE SASK,

23060 NORTHLAND FISHERMENS COOP A PA IC HO 0 831011 831011 B WEYAKWIN SASK,

23061 NORTHWOOD LAKE IC HO B NORTH WOOD LAKE SASK. 23064 OLIVER LAKE IC HO c OLIVER LAKE SASK.

23006 OSSEY FISHERHENS COOP-BIG SAND IC HO 0 0 B BIG SANIIY LAKE SASK.

23087 OSSEY FISHERMENS COOP-BLTN BAY A DR IC PA HO B BALLANTYNE BAY SASK. 65

UNREGISTERED PLANTS - SA1SKATCHEWAN

ZONE 3

Plant rlant asent oPeration months last TS water test ice test Plant nu111ber name/locatic1n t!!Pe JFMAMJJASOND date date date class !!!!Blllldd !:l!!Rlllldd !!Ylllllidd

23052 OSSEY FISHERMENS COOP-LUIESTON IC HO 00 c LIHESTONE LAKE SASK.

23069 PEASE LAKE IC HO c PEASE LAKE SASK. 23076 PELICAN NARROWS COOP PA IC HO 00 c SOUTH WOOD LAKE SASK.

23080 PELICAN NARROWS COOP-STPHILL HO IC 0 c STEEPHILL LAKE SASK+

23089 PELICAtl HARROWS COOP-UKOOP DR PA IC HO 0 B UKOOP LAKE SASK.

23090 f'ELICAN NARROWS COOP-USKIK DR PA IC HO 00 B USKIK LAKE SASK. 23068 F'IKOO LAKE IC HO c PIKOO LtlKE St1SK. 23066 F'IKUSIKUN LAKE IC HO c F'IKUSIKUN LAKE SASK.

23008 F'INEHOUSE FISHERMENIS COOP-BESN IC HO 0 B BESNARD LAKE SASK.

23010 PINEHOUSE FISHERMENS COOP-BLBR IC HO c BLACK BEAR ISLAND SASK. 23062 F'INEHOUSE FISHERt!ENS COOP-NEED IC HO c NEEDLE FALLS SASK.

23065 PINEHOUSE FISHERMENS COOP-f'NHS PA IC HO 000 0 B PINEHOUSE LAKE SASK.

23072 f'INEHOUSE FISHERMENS COOP-SFLY PA IC HO 0 B SANDFLY LAKE SASK 66

UNREGISTERED PLANTS - SASKATCHEWAN ZONE 3

Plant Plant asent operation 111onths last TS water test ice test Plant number na111e/location t!:IPe JFHAHJJASOND date date date class !:1!:111111tdd !:l!:llllllidd !:l!:llllllldd 23067 PITA LAKE PA IC HO c PITA LAKE SASK, 23070 PRIMEAU LAKE IC HO c PRIMEAU LAKE SASK,

23071 REEDS LAKE IC HO c REEDS LAKE SASK.

23020 SAHDY BAY FISH COOP PA DR IC HD B SANDY BAY SASK.

23086 SAPROCOLLE F.JR. DR PA IC SH 0 B GOODSOIL SASK.

23073 SISIPUK LAKE IC HO c SISIPUK LAKE SASK. 23082 SLED LAKE IC HO c SLED LAKE SASK. 23081 SMOOTHSTONE LAKE IC HO c SMOOTHSTONE LAKE SASK. 23074 SOKATISEWIN LAKE IC HO c SOKATISEWIN LAKE SASK, SASK.

23075 STURGEON LAKE FISHERMENS COOP PA IC HO B STURGEON LANDING NAMEW LAKE 23078 SWAN LAKE IC HO c SWAN LAKE SASK. 23083 TAPESE LAKE HO IC c TAPESE LAKE SASK.

23108 THURBER G, IC HO 0 B CANDLE LAKE SASK. 67 UNREGISTEREll PU1NTS - SASKATCHEWAN

ZONE 3

Plant Plant asent operation months last TS water test ice test Plant number name/location tYPe JFKAHJJASOND date date date class !:l!:ll!ll!ldd !:l!:llllllldd !:l'.:llllllldd 23038 TOBY F. IC HO c GREE!l LAKE SASK ..

23093 WAPAllEKKA FISHERMENS COOP FIH IC HO 0 c 1 ST. ICEHOUSE SASK ..

23092 WAPAWEKKA FISHERMENS COOP FNAR HO IC 0 000 0 B 1 ST NARROWS SASK .•

23091 WASEKAMIO LAKE IC HO c WASEKAIHO LAKE SASK ..

23018 WATERHEN BAND COOP FISHERIES PA IC HO 790905 B WATERHEN LAKE SE KIP 23094 WINTEGO LAKE IC HO c WINTEGO LAKE SASK .. 68 UNREGISTERED PLANTS - SASKATCHEWAN ZONE 4

Plant Plant a~ent operation months last TS water test ice test Plant nu111ber na111e/location t'::l?e JFHAtlJJASOND date date date class !:l'::llllJlldd !:IYlllllldd !:l!illtllldd

24004 BOTHAM AND SONS PA IC HO DR 0 B DIEFENBAKER LAKE-SAK.LANDING SASK. 24001 COLT LAKE IC HO c COLT LAKE SASK, 24002 FLEMING LAKE IC HO c FLEMING LAKE SASK

24003 H&O ENTERPRISE_S PA IC HO B PASQUA LAKE SASK,

24005 LAKESIDE FISHING LIMITED PA DR IC HCI 0 B DIEFENBAKER LAKE-SAK. LANDING SASK,

24006 MARTENS , DOUG PA IC DR HO 0 B DIEFENBAKER LAKE-SAK.LANDING SASK.

24007 MURDOCK , ALLAN PA DR IC HO 0 B DIEFENBAKER LAKE BIRSAY

24008 VOLLMER , ROSS PA DR IC HO 0 B DIEFENBAKER LAKE LOREBURN

24009 WESHlIHD FISHING LIMITED PA DR IC HU 0 B DIEFENBAKER LAKE-SAK.LANDING SASr:. - 64~ -

Alberta Unregistered Plants Classification Listing by Zone 1.

rl

I ~5 8 p

I I~ ~· . 54c- ;/ - ,.i

J -~N0'-- ~~

ALBERTA 1. Zones outline major fishing areas, transportation and mam1gement activities. They do not necessarily reflect industry delineation and a,re subject to change. 70

UNREGISTERED PLANTS - ALBERTA

ZONE rlant rlant a!:lent o?eration months last TS water test ice test rlant number name/location t!:l?e JFHAHJJASOND date date date class '.:.i'.:.illlll!dd '.:.!Ylllll!dd '.:.!Ylll!dd

11001 ATHABASCA FISHING COOP A DR PA HO IC 910825 B FORT CHIPEWYAN ALBERTA

11002 FOUR MILE LAKE IC HO B FOUR MILE LAKE ALBERTA 71-2

UNREGISTERED PLANTS - ALBERTA

ZONE plant plant a9ent operation months last IS water test ire test plant number name/location type JFHAHJJASOND date date date class yymmdd yymmdd yymmdd N.W . T , Unregistered Pl ants Cl ass1ficatio. n Listing. by Zonel.

, , , ' , '

...... 2 '• ... . ·, ' .... ( ...... ~ I " 1 1. z .. .J . . . 'l:, \'-., ~ ' (} ones outl. • • • ""../'"' '\,._,/.--;.' v -~ • J areas, major fishin... 8 tra~~eportation ad g ·-..~/ ~~"'-. "\ \ 1~ctivitie ndustr" 1 . They do management·. ,.,,.,., , .e.1neation •nrl necessari 1 .. • • ;r ~, -no~.. - are "'". Ject· Y toreflect· chanqe - .- ... -- - - .. - .. : ...... JI ' 74 UNREGISTERED PLANTS - N.W.T. ZONE rlarit Plant asent operation ruonths last TS water test ice test Plant n1Jmber name/location l':!f'e JFtlAMJJASOND date date date class ';:l':lmmdd !:l':llltllldd ':l':lnlllldd

51004 F.F.M.C. HORRAINE BAY A PA IC HO 000 840328 830823 830823 B MORRAINE BAY-GT.SLAVE LAKE N.W.T,

51005 KAKISA LAKE FISHEHY IC HO 0 830614 830614 B KAKISA LAKE N,W.T,

51006 U:C LA MARTE FISH CAHF' DR PA IC HO B L(1C LA MAF:TE N.W,T. 75 UNREGISTERED PLANTS - N.W.T,

ZONE

Plant asent o?eration months last TS water test ice test Plant numbei· nau1e/ location t':IPe JFMAMJJASOND date date date class YYllllllOd YYmmdd YYmmdd

53002 HARRISON J. IC HO Pt1 PR 0 830803 c MCKEMZIE RIVER NWT 76

UNREGISTERED PLANTS - H,W,T.

ZONE 4

~l.>nt Plant asent oF·erat ion months last TS water test ice test Plant number riame/location l\:IPe JFMAMJJASOND date date date class 1~\:llllllldd

34002 BYRON BAY - DR PA IC HO 830829 830829 c BYRON BAY N.W. T.

54001 GOVT.OF NWT - DR PA IC HO c ELLICE RIIJEF; N.W. T,

54006 KOOHIUT COOP PLANT DR PA IC HO A PELL 'I Bir! N,W IT.

54007 F'ERRY F:IVER FISH PLANT DR PA IC HO B F'EF:F:Y F:I 1JEF: rLW.T,

5400E: WELLINGTON BAY FISH PLANT DR PA IC HO B WELLINGTON BAY N.W. T. 77

UNREGISTERED PLANTS - N.W.T, ZONE 7

?lant Plant a9ent o?erat.ion 111onths last TS water test ice test Plant number n<:mellocatior1 t'::l?e JFMAMJJASOND date date date class '::l'::llllmdd

57003 FROBISHEF: BAY BASE FREEZER FR B FROBISHER BAY N.!J. T. r:---1\1''1 JJ ,v~ FROBISHEF: BAY PL1;NT DR PA IC HO B FROBISHER BAY N.w.-r.

57001 NETTLING LAKE PLANT DR PA IC HO .B NETTLING LAl\E N.W. ' 57004 F'ANGNIRTUNG FISHERY F'R FR c F'ANGNIRTUNG N.w.r. 78

UNREGISTERED PLANTS - N.ld. T.

ZOflE 8

? ldr1t Plant asent operation months last TS rtJater test ice test Plant number nau1e/location tYPe JFMAMJJASOND date date date class YYllJll!dd ':!':illlllldd ':!Yllll!ldd

58010 ARCTIC TERN - T.EECHERK VESSEL DR PA IC HO 810613 830825 A ESKIMO POINT FR N.lJ. T,

58002 BARBOUR BAY FISH CAHP DR PA IC HO BARBOUR BAY N.W.T.

58013 CHESTERFIELD INLET PLANT PA IC HO 0 830803 CHES fERFIELD NWT

58003 CGPPER NEEDLE FISH CAMP DR PA IC HO 770829 B COF'PER NEEDLE N,W, T.

58004 CORBETT INLET FISH CAMP DR PA IC HO 770829 B CORBETT INLET N.W. T.

58005 FERGUSON RIVER FISH CAMP PA DR IC HO B FERGUSON RIVER N.W.T.

~8006 KAMINAK LAKE FISH CAMP PA DR IC HO B KAIHNAt\ LAKE N.W. T.

58007 SANDY POINT FISH CAMP PA DR IC HU: B SANDY POINT N,liJ,T,

58008 STONEY POINT FISH CAMP DR PA IC HO 770829 B STONEY POINT N,IJ, T,

58009 SUF:REY RIVER DR PA IC HO c SURREY RIVER N.~J.T.

58011 THIRTY MILE F:IVER DR PA IC HO c THIRTY MILE RIVER N.lJ, T.

58012 WH?1LE COVE PLANT IC HO 830803 B WHALE COVE N.W.T. 79

UNREGIS!EREII PLANTS - N.W.I.

ZONE 9 plant plant agent operation 11onths last TS water test ice test plant number name/location type JFHAHJJASOND date date date class yyrnmdd yy11mdd yymadd

59001 PORI BURWELL FISH PLANT DR PA IC HO c PORI BURWELL N.W,T. FIGURE 2 " TEAM SURVEY FORM

The team survey form is designed to consolidate sections of the FIR pertaiing to the same basic areas of the plant. It deletes sections irrelevant to plants in this region. 80

FISHERIES ANO OCEANS - SOUTHERN OPERATIONS DIRECTORATE I WESTERN REGION TEAM SURVEY OF FISH PROCESSING ESTABLISHMENTS

Plant Name ------Plant 111 2 J Location ------3----·------Registration #1 I 4 J Overall plant classification A c: Date 7 timE! 3 hrs. 6 YY mm dd Surveyed by CJ CJ-CJ CJ Action level _9_ 10- Operation Type ho ic pa dr sm pr pi cm fr fi sc br ca Operating season J F M A M J· J A S 0 N 0 Number of employees 12 1_1 Number of fishermen 13 Number of lakes servic:ed _14_ Landed poundage ·--""15;;.___

Fon11 fish shipped fresh(l2) , frozen(l6) , round(20) , headless (17) , others (99) -12

Shipped to ------1_7______Transportation system in______...,,______Type ______..19 ___ _

Transportation system out ______..;2;;.o;;._, _____ Type ____...;2;;..;1..._ ___

The deficiencies listed below have been discussed with ______.....;;2;.;;;2~------Position 23 .Deficiencies are to be corrected by ___ _.2._4___ _ unless otherwise note

F. I.R. correction ~ .. .-:ti on Corrective action date 25 :t6 27

! i

Aclmowledged by ______2_a ______

Fonn PS - 101 (83/06/01) 81

•• 2 - C - Comply NC - Ooes Not Comply HA - Hot Applicable Sect. No. Oe:scriptlon c NC NA Coll'l'lll!nts

Floor$ - Wet \lork in9 Area 101 a) finish • 1:ype b) repaie· c) slope d) floor·•w.al I joint Floor Cleanin•i - '.Jet Are.as 242 a) ..ashdown during work period

b) w

~- J)res en t 103 lll) 50!00 tli i!r>d impervious

b) adeq u.11 te size c:) proper iy trapped and covered

~ - Yet Yorking Are.a 104 a) smooth surfaced b) c:rac:k free c:) w;nerproof d) light coloured

e) c:urbs hi g:her than 12" require oaint f) can be thoroughly -shed to I+' II t l e.11$ t g) windowsills sloped inwards

Ceil i n51s - Processing Areas 135 a) smooth surfaced

b) c:rack fre!e c) washable

d) Ii gh t coi oured e) free of 'ledges f) 9 ft. minimum height for n- o Ian ts Exeosed Pipu and Ducts none over 'WOt'"k areas where fish processed

Light i n9 - P·roc:ess i ng Area 115 a) 20 f·c. c.nndle minimum

b) fixtures not suspended c:) protec:t i ve c:overs

Floors - .Q!i'.. Working Area - 102 a) good re;:>ll i r b) prop.erly c:onstructed

\Ja 1 ls - £!:L_ llork Areas 129 a) smooth b) c:rac:k frn c:) wa ter:iroof

d) Ii gh t c:o loured

Vent i I a c ion 105 a) odour ref!IOV.111 b) humidity c:on tro l 82

- 3 - C - Comply NC - Does Not Comply NA - Not Applicable >ec t. No. Oescr i pt ion c NC NA Comments

~ 106 a) adeqlJdlte number b) ventilated c) .approved cons true: t ion d) approved location I Toilet room doors I 11) provide isolation 107 b) self-closing

Toi let areas a) cleaned regularly 206 b) to i 1et paper present cl floor kept clear

Handwashin~ Facilities al ho t and co Id ,... te r 108 b) soap dispenser c) single service towels d) waste towels receptacle e) visibi 1 i ty from ..ark are& Handwashinsi 202 done after absence from line Hand Cover i "2 Di es 137 a) provision b) convenient location

240 Hand Coverins Oisinfectin2 a) at each break

b) washing be tween breaks

Yater Supply - Processing Yater 109 a) approved source b) bacteriological qua I ity c) 20 psi pressure d) treated when necessary Yater Supply - Hot Yater a) available for clean-up 136 b) 110° F minimum temp.

Yashins Round and Dressed Fish a) done prior to further processing 235 b) 904 bacterial reduct ion -Ice Sanitation 236 a) satisfactory bacteriological n , .~ 1 • •• I ' • I 1 nr1 - 1 \ b) free of fcre i gn matter c) non corrodible containers d) holding facilities kept clean 83

C - Comply . " - NC • Does Npt Co~ I y ••r• ··-- ...... ---· - >.:c: :. Nlo. 01!scription c 1•C NA Comments ...... == Offal Containers 12 ll) approved ,,,,ueria I b) ,,..tertig1ht c:onstruction -·c:) fi cted lids . d) wash

208 a) remiov~'1'J at least once/day b) equipment kept clean c) method of di$posal sat is fac tor'y 09 Of fa i Container - used for offal only

Liguid s.ewa~e Oises?sal

07 a) isol.mced from water supply b) inac1:essible to flies

l3 I" i sh Conveyors • approved ma tar !.1 I

Con v!Yor CI e.1n i nl:! Meehan isms 42 a) '"'

Fish Flume Cm1struction 14 <1) approv~ material

b) smooth s1Jrfac111

10 E9uiement Frames - approved material

Precess i l"lj;! T

Proc1~:uinS! !k1ards and 13locks a)

Other Fi"Sh Ccirotoict Surfaces 39 <11) appl"OV!l.d AMI teri ii J ,__,b) Stillt'l of repair

Fish Contact Surfaces - washed prop- 2 i4 erly and disinfected a• end of"""'"" ~kih

~o Proces;sin•9 Containers and Utensils a) approved materials ~.tate of repair

'\.Ii l"tl! Mesh Ute,ns i Is - use not a I lowed 43 ex·cep t for hand I i ng she 11 fish

Enamel led Utomsi ls use not al lowed 44

'---· 84

- 5 - C - Co100 I y HC - Oo1es llo t Comp I y uArs _ Mo ..c:.-ifl.D.pljc;able .. Sec:t --- Desc:ri pt ion ~- c NC Hll I Corrmen u Utensil Cleanin9_ 243 a) cleaned during shift b) cleaned at end of shift

c:) air drying and sani t~ry stora9e at sh i ft end ., Fish Holdino Containers ~. ! .l) ap~roved material I b) state of repair c:) provision for drainage

Emelol'.ee Hut th - - Wl a) no Carriers b) no c:orrmunic:able di$ease cl no ooen wounds or sores 203 F in~e rna i 1 Polish not allowed 205 No Smokin2 - No Seittin2 -- \./ater2roof ~arments 204 a) c:leaned at end of ..ark shift b) hung up at breaks

L Outer 9.11rments 241. Ji) smoc:ks or c:overalls "'°'n b) clean I iness of gar!llO!lnts c) headgear worn

(1_) Outer ~arments - Cold Stora9e - kept cl e11n ---- 210 No animals al lowed in plant 211 Pest Control Program a) insect e.xc J us ion b) insect e.x.tennination procaram c) rodent exc:lusion d) rodent extermination oroar·am e} approved m.!lterials only I Eouipment Storage - only materials I 212 in processing operation allowed I in ,,orking areas 213 Surrounding Area and Beach - kept clean 214 Cleanin~ Equipment available in plant

General l'l

c - Comply HC - Ooes Hot CO"'PIY -' - NA - Not Applic•ble Sect 'fo. Description c NC NA COft911ents

145 Cooler 1nd Freezer Cor.ioli•nce Cont•ct Freezers

1" thick block to-21°C In 2 hours

146 lllut Freezers 1) -30° C 1 Ir temp. b) 2 meters/sec. minimum velocity 401 Cold Stor•s• te11111 1111intained ( .26°C

149 Ingredient scor!9e •reas •l rodent Mid pest proof bl dust •nd we1ther proof c) appl"Oved bulk cont1iners Conmen ts

Sketch of Plant Dl ..nsions: - 86 -

The Team Survey form is to be completed as folloW's:

1. Pl ant Name: full 1ega l name 2. Plant Number: as_ per plant listings,

3. Location: name of town, city or lake and province where plant is located

4. Registration No.: as per registration certificate or marked as "UR" for unregistered locations

5. Overall Classification Rating: as per plant classification criteria

6. Surveyed By: use assigned inspector number (if no number assigned, insert name to the right)

7. Date of Survey: day completed (year/month/day) 8. Time: time required to complete survey including discussion with management

9. Action Level : as per manual

10. Operation Type: circle all types of processing carried on during the year at that location

11. Operating Season: circle normal months of operation

12. Number of Employees: actual numbers or range if seasonally dependant 13. Number of Fishermen: number of fishermen if applicable delivering to that plant 14. Number of Lakes Serviced: actual number or range 15. Landed Poundage: weight of product delivered to the plant or for processing actual poundage produced 16. Form Fish Shipped: circle or underline as shipped from plant

17. Shipped To: immediate destination after shipping 18. Transport In: mode of delivery 19. Type: open, closed, refrigerated, etc.

20. Transport System Out: mode of shipping

2.1. Type: open, closed, refrigerated, etc.

22. Discussed With: person with whom corrections were discussed - 87 -

23.. Position: status of person in (22) in regard to the plant (e.g. manager)

24. Correction Date: if all deficiencies are for the same date, mark that date in this space or mark the season by which the deficiencies must be corrected. If deficiencies' corrections are for a variety of dates mark "see below" in this space.

25. FIR Section: mark appropriate SE~ction of deficiency

26. Corrective Action: description of action required

27. Correction Date: for each defidency (year/month/day)

28. Acknowledged By: signature of person of authority to whom you have discussed the deficiencies

e pages following are to be completed during the Team Survey as complies with F.I.R. 1 s, does not comply or is not applicable. Comments that ght give more insite into the plant and observations that will inform as to the item did not comply go into the! comments column.

Pictures are required as part of the Team Survey. A sketch of the floor plan and any comments that were not included in the previous pages are to be included on the last page.

88

FISH PLANT REPORT FISHERIES AND OCEANS-SOUTHE.RN OPERATIONS DIRECTORATE /WESTERN REGION 1 Plant nom© Loc:ati°';, 2 Plant No. I l l:sl l lReg.# [fil] 1 Op@rah:in tj/1)411 S Season JFMAMJJtiSOND Photos Yes/No Timct retC11uired D!IJ hours l~tOf No. [!IJ ~ Inspection I!] Foilowup lnapection ~ Survey ~ Followup Team Surve:v J6 f l.R. 14 u Not 17 HI S

101 Floor11 - W@t work area 242 Floor!\\ - Cl@on 102 floor11 - Orv work area 103 Oroin11> - Ad110uotei, Covered 104 Walls - Wet area 135 C111ilinas - Processina oreo 115 1 inMino - Adeouot111. Coverlld 105 V111nti lotioo - Adecioote 906 Toll@Vs - TvP®s/num~s 107 Toilet r004'l'I door11 - Hif cl011ino 206 Toilet h1ciliti11s maintained IOS Handwo111h tocilities - oooroved 202 Hom:!wcsliioo - eoch obscence 137 Hand CO'lllllrina dill$ - orovidod 240 Harn:ko1111rinQJl'I clean and disinfected 19 20 109 Process water - onnroveci/Dressure somr,iled yes/n·~- 136 Hot water - at least 43" c 235 Fish washed - orior to Nocessina ::n 236 le® - a01Yo11eci sampled yes/110 112 Offal contain~m; - aooroved 200 Offal /refuse - removed doil11 209 Offal contoiners - aooro1111d 207 ~age diiioosal - onnro1111d 113 Convevors - approved 142 Convevor belts - sorov I scraDE!tr 114 Fish flumes - aonroved /cleanable 110 Eciu1o~nt frames - aooroved Ill Tables - aooroved/cleonoble 138 Processina boords - aooroved 139 Other fish contact surfoce11 140 Containers/utensils - oooroved 141 Fi:11h tubs/containers - oooroved 243 Utensils - clean. disinfect stored 244 Fish cootoct eouioment - clean 201 Employ" health - satisfactory 205 No smokina/11oittino - work area 204 C'°rments - clean 241 Garments/ h!QQgegr - l!Q!:n I ~r2'1!!r tvc.11 210 Animals - not allowed 211 PHt control - ooecniote I materials 212 No un111c111:!1Scw1 ~uipment - work oreo 213 Pkmt surroundinos - clean 214 Cl111on1no 111ouioment - available Z45 G@l')l'lfol mointenonc111 - sati$fa<:torv 145 Contact frlK!zer - odeouote 146 Blast freezer - odeQuate 401 Cold stoma® - odequat111 '®mo. 149 lno;;in11di1111nt storooo - adequate OVERALL PLANT CLASSIFICATION RATING A B C D - 22 ACTION LEVEL ...1l... CorrKth1@ octioo ( ph1101>e print) Correction dote F.l.R._24 SKtion 25 YY/MM /[)0 ~ ~ 26 - :=::::::::::::::::::::::::: ~' ~ ' • • A_ __.&_Jl_ ____A .. _.I_ ..__.L _ __A .A. IL_.~----"--··-"--•A.-...J -+--

"-~+-'-~~~~~~_.__.__.__.__.__._...... _.. _... -L __A.___J,_,____./i.._ __ -'L...._,L____._.,_, _____,.______t.

··~··---··~-···~·-·''- -+-

~--~ ---~- -~ __,...__ -h--~-----""'- __,.,_ ___ •. --• ..... "-. ··-· __ __._ -A---~~_l ____ ...... _ __ .____ .______A ._

• -• -~ ~ ~-L~ ~ •--• • ~ ~·--' -. -+-

••• .__ .. ~ _,, .__ "----1...-----"------~-__L____._ __.._ ___ _,, _L_ -~---" ..•• ,-..JI..- .--1-- 27 21 ABOVE DEFICIENCIES ACKNOWLEDGED BY POSITION "------"-- _. ___ ,_ ____ .._ A __ A. ___ ..______,. __ ___,L..-!

-- .-.-. I-- IA I~\. lncnart inn do.ta 29 N~ 1 - 89 -

The Fish Plant Report form (FPR) is to be used for all inspections carried out by local officers. Where an officer is in a plant several times or continuously during one day and the inspection is ongoing, that shall be considered as one inspection and be recorded on the FPR as such for that day. Whenever a plant is visited for the purpose of sampling a product, or water and ice, or for any reason other thain for a plant survey or plant inspection, the inspectors should also check plant operations (ie. complete an inspection and fill out the FPR form accordingly). Where no inspection is done, the visit to the plant should not be considered as an inspection and erefore, not recorded on the form. One form is to be used for each inspection or survey. After completion, the copies should be distributed as follows: 1) Original (white) to be sent to the Reqional Office. 2) 1st copy (canary yellow) to be given to the Plant Manager. 3) 2nd copy (pink) to be sent to the District Office. 4) 3rd copy (golden rod) to be retained by the inspecitng officer. The information recorded on these forms is to be sent in to District and Regional Office as soon as possible after completion to permit les to be kept updated and plant progress to be continually monitored. All forms for a particular month should be received by Regional Office by the end of the first week of the following month. The information will also be used for MIS monthly summaries of Plant Services Activities. Level Action codes based on the following definitions will be assigned to the inspections and surveys: -· 90 -

For Team Surveys: LEVEL II ACTIONS: Surveys of plants resulting in requests to carry out modifications but not resulting in refusals to issue certificates or in cancellations of certificates. LEVEL III ACTIONS: Surveys of plants resulting in refusals to certify the plant or in cancellations of certificates. For Inspections: LEVEL II ACTIONS - PLANT: Each plant inspection resulting in any action which does not result in closure of the plant, discontinuation of operation or prevention of product form reaching the consumer will be reported as a Level II action. For example: Instructions to remove unniecessary equipment being stored in a working area. LEVEL III ACTIONS - PLANT: Any plant inspection resulting in a discontinuation of operations or a closure of the plant to prevent product produced under the operating conditions noted from reaching the consumer. For example: Stopping the production of fish sticks until a plant clean-up has been carried out. - 91 ·- Fish Plant Report (FPR) forms are to be completed as fo'llows:

1. Plant Name ••••• name of the plant as it appears on th1:? registration certificate or official name. 2. Location •••• specific town/city or lake where olant is located.

3. Plant Number • as it appears on plant lists. Leave blank if not on lists. Where a plant on the list has been replaced by a new plant, use existing number. 4. Registration Number as per registration certificate (where registered). 5. Operation Type ••• list types of opierations being carried out at that plant.

6. Season • circle months that the plant normal operates. 7. Photos . • • • • • • circle either "yes" or "no" as to photographs being taken during the inspection/survey. 8. Time Required total time required to actually carry out the in­ spection, fill out the form and discuss deficiencies with plant representatives. (To the nearest 1/2 hour).

9. Inspector Number •• use inspector number as assigned. (See Lake Classi­ fication and Inspection Procedures Manual) Where a number has not been assigned, print your name immed­ iately below. 10. Inspection • • • • • check box where the FPR is being completed during a formal inspection.

11. Followup Inspection check box where the FPR is being completed during a followup to a specific inspection where deficiencies were noted and were to have been corrected ..

12. Survey ••••••• check box where an exceptional report is carried out at plants that are inspected daily or on a regular basis during the week. The exceptional report ·is used where an inspector finds deficiencies that are to be corrected but during "regular"' rounds for pro-· duct inspection or other routine duties. (Not during a formal inspection where the form is be"ing completed during the inspection.) 13. Followup Team Survey check box where FPR is filled out on a followup to deficiency corrections listed during a team survey. 14. Requirement the numbers on the left and their headings corres­ pond to standards listed in schedules 1, 2, and 4 of the Fish Inspection Regulations (FIR).

11 11 15, 16, 17, The column comply , "not comply", and "N/l\" ar1e to be checked off appropriately. 15. "Comply" is to be checked if the requirement listed is fully satisfactory. 16. "Not Comply" is to be checked ff if the requirement is not satisfactory. -· 92 - 17. "N/A" should be checked if the requirement does not apply to that particular plant situation. ALL requi rernents are to be checked off with either one of these sections.

18. Description and Remarks - The nature of the deficiency should be recorded here.

19. Water Sampled Circle (yes/no) appropriately whether or not samples were taken during the date the FPR was completed.

20. PPM Clz Fill in chlorine reading where a water source has been tested that day for chlorine content. Use whole numbers only. (Round off where a decimal appears). 21. Ice Samples Circle (yes/no) appropriately whether or not ice samples were taken during the day the FPR was completed. 22. A, B, C, only . . • should be encircled, according to the definition in the Plant Inspection Procedural Manual. The "O" designation is for future use only for "Establish­ ment Rating Systems" being developed currently. (Do not circle 11 0 11 until further notice). 23. Action Level . • • • 1, 2, or 3 is to be filled according to definitions int he Plant Inspection Procedural Manual. (See page 100 of Book 5, 1983 edition). 24. F.I.R. Section . • • Fill in the FIR section (see 14) where each de­ ficiency exists - e.g. 101, 242, 401. 25. Corrective Action • Describe the corrective action for the appropriate deficiency code in (24). Print, be brief yet clear and restrict comment to the number of spaces alloted for each letter. Use another form or carboned memo paper to continue an extensive deficiency "Ii st. Ensure plant numbers and inspection dates are included on the supplementary form. 26. Correction Date • • Establish a date for the correction of each defic­ iency listed and write in. The date must be marked as year/month/day. e.g. 83/11/01 (November 1, 1983). 27. Acknowledgement • • Have the plant representative that you have discus­ sed the deficiencies with sign here (if a represen­ tative is available). 28. Position. . . • • • Print position (manager, owner, etc.) of the repre­ sentative who acknowledges the corrective action and signed in (27). 29. Fill in the Inspection Date. The date must be mark­ ed as year/month/day. (see 27 for examPTe}. Only one date is to be entered for each Plant Inspection Report. (i.e., one report per inspection, survey, or except i ona. l report). - 93 - ') I I I

For the purpose of ensuring that all of the facilities and equipment and clean-up procedures are checked, the Sanitarians Check Sheet listed below may - be used as a supplement of FPR.

-

SANITARIANS CHECK SHEET 41. Wells clean 42. Handrails, window sills clean A. BEGINNING OF DAY OR SHIFT 43. Frozen storage arees tidy 1. Rinse down surfaces, sinks, t•nk1 44. Packaging m•t•rial protected 2. Personnel correctly dressed 45. Utensils sanit•ry, not worn 3. Personnel pre-work wash up 46. Washrooms clean, disinfected 4. Sink water supply adequate (1100 F) 47. Floors clean 5. Uten1il dipt correct strength 48. Lights, vents end screens setisf•ctory 6. Hand dips correct strength 49. Floora, wells, callings condition B. DURING OPERATIONS 50. Evidence of insects or rodents 51. Dr•in1 free flowing 7. Water pressur• 20 p.s.I. 52. Fin•I disinfectant, rinsedown 8. Utensil and hand dips changed, correct 53. Utensils eir dried, protected Hrength . 54. Pesticide• used where needed 9. Chlorine et opereting levels (5 ppm) 55. Cleaning equipment put away 1 O. Scrapers, sprays working 56· Unprocessed fish cooled 11. Jets, F eucetl working properly 12. Flumes free flowing 13. Drains free flowlng 14. Work eree clean 15. Containers 1anltlzed after each UH 16. Surfaces, utensils kept unitary 17. Doors kept closed 1B. Proper handw111hlng procadurft 19. Proper dreu 20. Washrooms clean, equipped 21. "Offal containers.not on·llne.lldded" C. AT BREAK PERIODS (LUNCH BREAKS) 22. Chlorine et clean-up levels (50 ppm) 23. Tables cleared 24. Forceful wuhdown of all erea1 25. Special attention erees cleaned 26. Gloves, aprons properly cleaned 27. Chlorine beck to oper•tlng level 28. Hendweshing properly on return D. END OF DAY OR SHIFT 29. Loading end unloedlng area cleaned 30. Outside area neat 31. Offal uea senitary 32. Clean protected lea 33. Containers, utensl11 unitary 34. Work areas uncluttered 35. Chlorine et cleen·up levels (50 ppm) 36. Hand covering end aprons cleaned •nd disinfected 37. Detergent, disinfectant strangthe 38. Tanks clean, disinfected 39. Surfaces clean, ..nltizad 40. ""Hidden pieces" cleaned (Underside of tables, rotary drums, ate.) ,...,.., (1t11r.v. 1/nJ ,..,.• .,, - 94 - \ \ \ \ Minimum Compliance Standards for FIR To assist field officers in interpreting and in enforcing compliance to the FIR the following charts have been added to provide a quick reference guide for Sections 3 to 18 of Part I of the FIR and Schedules I and II of the FIR. These sections are presently contained in the FIR, the Handbook of compliance and the national Fish Inspector's Procedural Manual. The minimum compliance standard charts summarize the sections of the FIR and contain only those sections applicable to fish processing plants in the Region. - The compliance section attempts to more explicitly outline the minimum requirements of FIR to be met by plant operators in order for registration to be issued or maintained.

-

- - - 95 -

MINIMUM COMPLIANCE STANDARDS FOR FISH INSPECTION REGULATIONS (FIR) PART 1 GENERAL

F.I.R .. Section# F.I.R. Summary

3 FIR apply only in respect of fish and containers intended for export or import.

4 All fish are subject to inspection and an inspector m~ take samples free for inspection. 5 The owner of fish shall make it accessible for inspection to an inspector.

7 Unless otherwise permitted by the Minister. fish shall be packed fo new, clean, sound containers. (1) No person shall export, process or attempt to, for export, fish unless all processing of that fish was carried out in a registered establishment. (2) #1 does not apply to one who exports, or attempts to, fish other than shellfish, caught and processed by a fisherman as whole or dressed unfrozen fish, salted or pickled fish. (3) Where the Minister has in writing notified a fisherman that there is serious contamination in the place where fish are processed by the fisherman, (a) no fish shall be processed in that place (b) no person shall export, or attempt to export, any fish processed in that place. 15 A registration certificate shall be issued by the Minister in respect of: an establishment where fish is processed and meets the requirements of Schedule I. 16 A registration certificate is not assignable. 17 The Minister may cancel a registration certificate, (a) where serious contamination is present (b) where the certificate was issued in respect of an establishment is not maintained in accordance with Schedule I and does not meet the operating requirements of Schedule II. 18 No person shall use a boat for fishing of for the transportation of fish for processing unless the boat meets the requirments if Schedule III of FIR .• 19 No person shall operate an establishment for storing frozen fish unless the establishment meets the requirements of Schedule IV. - 96 -

MINIMUM COMPLIANCE STANDARDS FOR FISH INSPECTION REGULATIONS (FIR) PART 1 GENERAL

Compliance 3 Fish processed in a registered plant is considered as produced for export and subject to FIR.

4 Products are normally inspected at the registered plant or storage facility. 5 Where inspector encounters difficulty in inspection the owner is responsible to make goods available.

7 Plastic tubs may be reused after thorough cleaning and disinf12cting. Sound, clean wood boxes may be reused within the region.

14 (1) It is an offence to export fish processed in an unregiistered plant. Anestablishment from which a Certificate of Registration has been removed,, or the Certificate has expired, must not process fish for export. If fish is processed contrary to the above legal action must be taken., (2) Fisherman-packers are exempt from construction and equipment requirements. He cannot export directly from his boat. Alli other FIR must be met. (3) Inspector may detain and send photo documented survey to Regional office 1 in the meantime. No processing of fish for export by fisherman 1where he s been notified in writing that there is serious contamination in his olant.

15 Schedule I of FIR must be met before registration certificate ma.Y be issued. Minor deficiencies for which there is a commitment made by the plant operator within an agreed time frame to correct may be tolerated. A team survey is completed before certificates may be issued.

16 No expiry date is shown on a continuing certificate of registration. A scheduled reappraisal of construction and equipment requirements is necessary. If ownership or name of plant changes a new certificate is required. 17 If a problem leading to product contamination is encountered, the inspector should notify District office with a recommendation for corrective action. District office will issue a warning, regarding withdrawal of registration and notify Regional office. If a plant me~:ts Schedule I but not Schedule II, it will not be registered, as non-compliance to Schedule II would result in deregistration. Therefore, plants should be team-surveyed for registration purposes when operating.

18 Vessel operators should be made aware of requirements and the benefits which will be gained in protecting fish quality with proper fish handling practices and sanitary operating procedures.

19 Requirements of Schedule IV, other than temperature, shall be applied to cold storages which are an integral part of the fish processing operation and are covered by a Certificate of Registration. (See cold storage survey procedures.) - 97 -

MINIMUM COMPLIANCE STANDARDS FOR FISH INSPECTION REGULATIONS (FIR) PART 1 GENERAL

F.I.R. Section # F.I.R. Summary

20 All conveyances, eg. vehicle bodies, boxes, tubs and barrels, used to transport fish to or from any establishment shall be clean and disinfected when necessary. 21 Fish intended for processing shall be adequately iced or chilled while being held or transported and shall be protected from contamination and the weather. 22 (1) Fresh. frozen, and semi-preserved fish shall be protected from contamination and the weather during loading and unloading. (2) Fresh fish and semi-preserves, while under control of a carrier, shall be kept properly chilled. (3) Frozen fish under control of a carrier, shall be refrigerated so that at its destination the temperature of the fish will not have increased more than 5.5°C from when it was loaded. - 98 -

MINIMUM COMPLIANCE STANDARDS FOR FISH INSPECTION REGULATIONS (FIR) PART 1 GENERAL

20 This applies to the individual fis;herman 1 s boxes as well as the plant 1 s containers. Wooden boxes that are reused should be disinfected after each use. (see box storage)

21 Open trucks not permitted unless an approved covering is used.

22 This section refers mainly to handling of fish after processing. (1) product should not be transported with non-compatible products. (2) good guality fresh fish must have been properly chilled on the way to market. (3) should inspector suspect that conditions may· result in a considerable rise in temperature, the temperature should be recorded prior to being loaded onto carrier. He should then contact District office and arrange to have temperature taken and the product inspected for quality at destination. - 99 -

SCHEDULE 1 OF FISH INSPECTION REGULATIONS (FIR) REQUIREMENTS FOR CONSTRUCTION AND EQUIPMENT

F.I.R. Section # Subject F.I.R. Summary

1 Floors-wet Surface of floors sloped·to drain and constructed working of materials approved by the Minister. area

2 F1 oors-dry Properly constructed of material approved by the Minister.

3 Ora ins Type and size sufficient to carry off process ef­ fluents and shall be equipped with devices to pre­ clude entry of gases or vermin.

4 Walls-wet Inside wall surface where fish is received, held, or processed shall be of smooth, waterproof, light coloured material acceptable to the Minister and thoroughly wash­ able to 1.22 m. 5 Ventilation Natural or mechanical ventilation systems shall provide clean air, remove undesirable odours, steam and smoke and prevent condensation in rooms where work is performed ..

6 Toil et Toil et faci l Hi es of types and in numbers approved by Faci 1it i es the Minister shall be provided. - 100 -

SCHEDULE 1 OF FISH INSPECTION REGULATIONS (FIR) REQUIREMENTS FOR CONSTRUCTION AND EQUIPMENT

Compliance

1 (a) Use well-finished metal reinforc1~d concrete or other approved coating. (b) Maintain in good repair. Caulk with approved material to avoid difficulty in cleaning. Severely damaged floors are to be redone. Use shrinkage control joints in new concrete floor construction. (c) Slope to drain-minimum 1/8" per linear foot in new construction. If slight pooling occurs, but otherwise the floor is in good condition, all water must be squeegeed into the drain at least once per day. (d) Floor-wall joints must be impervious to water. Cove, caulk or cement at right angles. Coving in new construction must be poured integrally with the floor.

2 Construct so as to be easily cleaned. Wood is suitable if it will not sag or crack. Maintain in good repair.

3 (a) Smooth, impervious and of sufficient capacity. For new construct ion drainage system should be approved by DFO Regional engineer. (b) joints and turns should be smooth and should not obstruct passage of solids. (c) Provide th traps if connected to a sewer. (d) Rodent-proof covers. Metal grates are to be in place at all times. Where floor is sloped to one corner or one wall to drain, hole must be screened. (e) Spillage should not create an unsatisfactory condition. ( f) Check-va 1 ve required if connected to sewer line. (g) Effluent discharge must be in accordance with Provincial Health Services and approved by local health authorities. 4 Joints to be watertight. Nothing is to be mounted on corrugated metal which creates uncleanable gaps. Walls are to be of tile, concrete, plywood, or equivalent material. Metal sheathing is not recommended, but if used, a solid coated backing must be maintained. Curbs .30 m. do not require painting. No obstructions which prevent extensive washing to 1.22 m. are permitted. There should be no horizontal piping or conduit etc. on walls or ceiling. Window s i 11 s in new construction to be sloped inwards or beve 11 ed and must be kept clean. {Outside walls must be adequately insulated to prevent condensation on the inside of the plant. 5 Screens are to be provided for a 11 windows and doors that may be opened to outside. Using outside air ventilation may cause condensation. Therefore mechani ca 1 fans a re recommended rather than having windows in the process area ..

6 1-9 employees require one toilet, 10-:24 (2 toilets), 25-49 (3 toilets), 80-100 (5 toilets), 1 toilet more for each 30 employees. Toilet rooms shall be adequately ventilated to the outside. Walls and ceilings shall be smooth, washable, light coloured. Floors sha'll be of impervious material and should ve floor drain. Toil et rooms require anteroom if located adjacent to processing area in new construction. In new construction, plant must utilize municipal sewage disposal system wherE~ possible. If electricity is available, ush toilets should be installed. Sanitary privies are p1~rmitted in isolated areas where there is no sewage collection or satisfactory area for a septic field. They must be 100 1 from plant and where there is no danger of contaminating water. Chemical or inc·inerator toilets may only be used in exceptional circumstances and with permission of Regional office. They are only permitted in private residences according to the National Building Code. Private facilities are acceptable for a limited operation. Facilities must be close to the plant. - 101 -

7 Toil et Rooms in which toilet facilities are located shall have Room Doors the doors of a type approved by the Minister.

8 Hand­ Sanitary washbasins equipped with hot and cold running wash in g water, liquid or powdered soap; air dryers or single service towels, and in locations and numbers approved by the Minister.

9 Water (1) Adequate supply of safe, sanitary water that supply (a) has coliform count < 2/100 ml or (b) is derived from approved source shall be provided at minimum 20 lb/in 2 • Unregistered "landing sites" require coliform count < 10 per 100 ml. {2) Other water may be used for auxiliary services if there is no connection between the water systems providing water to the establishment.

10 Frames and Frames of all equipment on which fish is processed Legs shall be of metal or other approved material.

11 Tab.les Tables shall be so constructed that they and the areas beneath can be readily cleaned. - 102 -

SCHEDULE 1 OF FISH INSPECTION REGULATIONS (FIR) REQUIREMENTS FOR CONSTRUCTION AND EQUIPMENT

Comp 11 i ance 7 Doors shall be self-closing (unless private residence). Door may be unnecessary where 2 right-angle turns are required to enter the room.

8 In new construction, handwashing facilities shall be visiblle from working area. Receptacles required for waste paper. Sinks must connect to drain outlet. Where power is available, hot water and cold water under pressure are required. Disinfectant hand dip required if hands are washed with cold water and soap only. 9 (1) Sample and analyze at least once every 6 months or every operating period. Immediate recommendations for improvement should be made by District to plants with bact. unsat. H20 and inform Regional office. Further samplin 1g should be done ASAP. If 1100 coliforms/100 ml an alternative source is required immediately and product should be detained, sampled, and analyzed. Usually, a well with 50 gal/min. provides sufficient quantity of HzO. (2) Municipal water supplies to be analyzed once per year.

10 Wood not permitted. Frames of corrodible metal eg. mild steel, must be maintained in good condition and painted and replaced where necessary with approved materials. 11 Stands for workers along processing lines shall be of metal, well-maintained and movable or so constructed that stands and floor beneath can be properly cleaned. - 103 -

SCHEDULE 1 OF FISH INSPECTION REGULATIONS (FIR) REQUIREMENTS FOR CONSTRUCTION AND EQUIPMENT F.I.R. Section # Subject F. I.R. Summary

12 Offal Bins (1) Bins in which offal is stored shall be water­ or tight, constructed of metal or other material approved Recepticales by the Mini st er, and where necessary to prevent con­ tamination of establishment or any fish being processed and be equipped with well-fitting covers. (2) A concrete or other suitable surface, sloped to drain, shall be placed under elevated bins.

13 Conveyors Wood not to be used for any part of conveyor that comes in contact with fish. 14 Flumes Flumes for conveying fish shall be constructed of non-corrodible material other than wood and able to be properly cleaned.

15 Lighting A minimum illumination of 20 1 candles shall be pro­ vided on all working surfaces in processing rooms.

35 Ceilings Process rooms shall have ceilings that are free from cracks, crevices and open joints and that (a) are constructed of smooth, washable, light-coloured material and (b) are of a height acceptable to the Minister. 36 Hot Water Hot water shall be provided and maintained at a minimum temperature of 43.3°C in sufficient quantity for the operations of the plant. 37 Hand Facilities shall be provided, at convenient location, Covering for disinfecting protective hand coverings used in Disinfec­ process areas. tant

38 Boards - Boards shall be of planed lumber or other material cutting, that is smooth, crack-free, and constructed in fin eting, approved manner. skinning

39 Surfaces Other surfaces on which fish is processed shall be (other of non-corrodible material, other than wood, all than #38) joints to be smooth and watertight. 40 Receptacles All receptacles and utensils used for processing Trays, Tanks, fish shall be non-corrodible, other than wood, and and Vats shall be smooth surfaced and crack-free. - 104 -

SCHEDULE 1 OF FISH INSPECTION REGULATIONS (FIR) REQUIREMENTS FOR CONSTRUCTION AND EQUIPMENT

Compliance

12 (a) Containers require covers except along processing line. Oil drums without lids are not satisfactory. Lids are to be kept on until offal is removed. - If continuous conveying system to fish meal plant is installed, design so that offal does not fall and create unsanitary condition. rketable forms of offal eg. fish skins for glue, frames and waste for animal food may be temporarily held in receiving or holding rooms provided sanitary operation of plant is not affected.

13 as stated. Free-flowing with smooth joints and bends so that debris is easily removed th H20. 15 Measure with light meter on each survey. Natural light may be used if 20 1 C maintained. For new construction lights must be recessed or surface mounted to eliminate ledges. Where ledges exist they must be hosed c 1ean daily. Tuff-skin bulbs or protective safety covers of an unbreakable material are required where fracture of a bulb might contaminate product. 35 As per Handbook of Compliance. Ceilings should be attached so that ledges on which dust may collect are enclosed above the ceilings. C1eilings in new construction must be a minimum of 9 1 a.nd' are required abov1e all processing areas. Exemptions for certain open b1:!am applications may be considered. Check with R.H.Q. Ceiling fans are allowed for air circulation provided they are kept clean. 36 It is required for handwashing and washing equipment after cold water rinse. In small packing or dressing operations a 20 gallon tank may suffice. Hot H20 under pressure is required for all registered plants. Temperature to be checked each survey. Hot water must be monitored at 43.3°C. 37 Required for all operations excluding holding areas. Locate in all process areas and change minimum lx per shift. Use iodine or 30-50 ppm. Cl 2 or other approved disinfectants. 38 No plywood, recommend plastic and hard rubber. Wash and sanitize frequently, nimum at each break. No cloth reinforced rubber or cloth-backed rubber permitted as the cloth may harbour bacteria and be a constant contamination source. 39 Does not include packaged fish. Surfaces of unloading chutes. thaw tanks, ghing boxes, scaler, washers, skinning machines, etc. which contact fish to be of approved materials, galvanized or other ineffectively coated surfaces or wood not acceptable. 40 Inside and outside surfaces must be smooth and crack-free. Wood, galvanized or other ineffectively coated metal and enamel are not acceptable. - 105 -

SCHEDULE 1 OF FISH INSPECTION REGULATIONS REQUIREMENTS FOR CONSTRUCTION EQUIPMENT

F.I.R. Section # Subject F. I .R. Summary 41 Boxes, All receptacles and utensils for holding fish shall Carts, Bins, provide drainage, if wood, use planed lumber or water­ Receptacles proof plywood coated with a material approved by the Minister. 42 Conveyors Belts that contact other than packaged fish shall have spray washer and where practical, a scraper. 43 Wire Mesh Not to be used in processing except for handling Utensils shellfish in shell. 44 Enamel Enamelled utensils shall not be used in processing. 45 Freezing ••• for processed fish must be able to reduce tempera­ Facilities ture at centre of 1" block of unpackaged fillets to -15°C in 2 hours. 46 Freezing Where round or dressed fish is not contact frozen Facilities use air at -28°C at velocity of 2 m./sec. or more. Until centre of fish is 20.5°C. 49 Storage Sufficient space, acceptable to the Minister, shall Ingredients be provided for storage of curing ingredients. - 106 -

SCHEDULE 1 OF FISH INSPECTION REGULATIONS REQUIREMENTS FOR CONSTRUCTION EQUIPMENT

Compliance

41 Fibreg1assing and coats of epoxy res"in or durable lead-fr1ee paints are acceptable. Reuseab 1e boxes for non·-export fish must be coated W'ith approved material inside and out. Discard old boxes.

42 Spray of approved water must remove debris. Where feas i b'l e al so use scraper, brush, ai rjets.

43 May be used in separating roe, and for dryer and smoking trays provided wire is non-corrodible and does not have twisted joints.

Enamel chips easily and could contaminate product. Do not use anywhere in plant.

45 Freezing facilities should be evaluated at least once per year and whenever problems in product quality occur USE? a thermocouple probe inserted into the middle of a fish block and monitored over a period of timE~.

46 Measure air velocity for new blast freezers, and when qua"lity problems exist and during team surveys. Contact Regional Headquarters for velometer use.

49 Store in clean, rodent and weatherproof location in good repair. If stored in bulk, other stored materials must not contaminate ingredients. - 107 -

SCHEDULE II OF FIR - OPERATING REQUIREMENTS

F.I.R. Section # Subject F.I.R. Summary

1 Emp 1oyees {l) no communicable disease. (2) no carriiers. (3) no open wounds or lesions.

2 Hand washing Fi sh handlers sha 11 wash hands with warm H2 0 and liquid soap after each absence from duty.

3 Fingernail Emp 1oyees handling fish with their bare hands Polish shall not wear fingernail polish.

4 Waterproof (1) Waterproof garments to be properly cleaned Garments after each work shift. and {2) Stored properly.

5 Smoke, No person shall smoke or spit in a working area. Spit

6 Toilets (1) Maintain in satisfactory manner. (2) Supply toilet tissue. 7 Sewage Sewage and liquid waste disposal not to contaminate water supplies or be accessible to flies.

8 Offal (1) Remove at least once daily. (2) Handle ·j n satisfactory manner.

9 Offal Used only for offal. Not for holding fish intended Bins for food, nor utensils or materials. 10 Animals Dogs, cats and other animals not allowed in estab- 1 i shment.

11 Rodents (1) Rodent and insect control program to be main­ and tained in every establishment. Insects (2) Pesticide application under supervision of resp. operator - prevent contamination. (3) Approved pesticides. (4) Rodent-proof screened drain outlets. (5) Fly stickers, strips and aerosal automatic dispensers not allowed. 12 Material Unnecessary equipment not to be stored in working Storage area. - 108 -

SCHEDULE II OF FIR - OPERATING REQUIREMENTS

Compliance

1 (1) Have management remove coughing and sneezing individual from work area. Ensure employees don't wipe noses in work area, and wash hands afterwards. (2) Wounds require adequate protection to prevent possibility of product contamination. Hands must be washed after each absence from a working area.

2 ( 1) As per H.O.C.

3 (1) Clean gloves may be worn over hands.

4 ( 1) H20 under pressure and use of brush. Remove all visible debris. (2) Do not place on equipment. Hooks to be provided.

5 (1) No smoking signs to be put up by plant management. (2) Off enders to be warned.

6 Keep clean, disinfect daily, keep floors clear of debris and moisture. Toilet paper to be available. 7 (1) Use municipal system where available. All system must be acceptable to Federal, provincial and municiple authorities. 8 (2) Offal pits should be at least 100 yds. from the plant and not create any unsanitary conditions. Check with local health authorities to ensure guidelines are not being violated. 9 Containers are to be marked in some way to identify them for use as offal containers only. 10 Keep doors closed and walls and windows in good repair. Insure no birds, nests, or droppings in plant. (See pest control section} 11 (1) If no apparent problem, plant and equipment disinfecting daily is sufficient. (2) Pesticides not to be used unless food is protected or removed, and potable water rinse on food contact surfaces given afterwards. (3) As per Table 5, electric zapper, series of fans, windscrean, Cl 2• (4) (5) Any evidence of rodents or insects sufficient to request an elimination and exclusion program. See Pest Control Section. ~ Only items required for use in processing operation allowed in working area. Unnecessary personal belongings are to be removed. - 109 -

SCHEDULE II OF FIR - OPERATING REQUIREMENTS

F. I.R. Section# Subject F. I. R. Summary

13 Surroundings Surrounding area and that controlled by an establishment shall be kept clean.

14 Brushes, Material needed for proper cleaning shall be avail­ hoses able at all times in a plant.

35 \~ash rnd (1) Round or dressed fish to be adequately washed & dsd prior to further processing. fish

36 Ice (1) Clean (2) Approved Source (3) MPN 2 Coliforms/100 ml. or less (4) Non-corrodible, clean containers

40 Hand (1) Disinfect at each break and shift end. Coverings (2) Wash frequently.

41 Outer (1) Employees, except filleters, skinners, scalers, Garments handlers of rnd and dsd fish, shall wear clean smocks and (2) headgear (3) not worn off establish­ ment or inside toilet areas (4) kept clean. (5) In frozen storage rooms workers shall wear clean outer garments. Filleter, scalers, skinners and other handlers of fish shall wear clean, water-proof, outer garments.

42 Floors In wet work areas to be kept (1) clean (2) thorough washed and disinfected daily.

43 Utensils­ (1) Clean. Cleaning (2) Disinfect. (3) Air-dry. (Placed in a manner to allow water to run off) (4) Sanitary storage at end of work shift. (Cl 2 30 to 50 ppm.)

44 Equipment­ All fish contact surfaces to be cleaned and dis­ Cleaning infected at end of work shift. 45 General (1) Establishment (2) equipment (3) utensils of Mainten­ operation to be kept in good repair and clean. ance - 110 -

SCHEDULE II OF FIR - OPERATING REQUIREMENTS

Compliance

(!]) Weeds and long grass to be kept cut, litter to be cleared away, equipment stored neatly and kept in sanitary condition. 14 Broom, squeegee, pail, scrub brush, disinfectant and soap required to provide frequent and thorough cleaning. 35 (I) Counts should be reduced by 90% after washing. Where unsatisfactory bacteriologically samoled product is obtained micro. checks should be carried out to determine the effects of washing. (2) Fish should be washed prior to dressing. Washing is required before filleting grinding, etc. to remove bacteria and extraneous matter. 36 {I) Avoid walking on ice as much as possible. Block ice to be cleaned by washing with approved potable H20 under pressure. {2) (3) (4) Containers may be of wood coated with epoxy resin or approved material. Ice-holding boards to be painted with approved coating also. Utensils to be kept clean. (3) Sample ice every 6 months or every operating period and analyze according to the standard methods manual. Sample more often if problems exist. l@ (1) Chat 1.0 to 50 ppm or 12 (colour of tea) (See Table 5) (2 ) Use approved water. 41 (I) Incl. packers, weighers. Smocks required as well as aprons. (2) Headgear must completely cover head. Baseball caps, if clean, are sufficient if person has short hair and it is not hanging on his forehead; hairnets required for long hair. (3) Suitable place for hanging smocks to be provided outside toilet rooms or at door to plant.

42 (1) Hose floors during work. ( 2 ) Disinfect (Table 5).

43 (I) (2) During and at end of shift. (3) Air-dry before stacking. (no contact with the blade and other surfaces) (4) Knife rack or other sanitary manner of storing. @ (1) Wash with cold H20• (2 ) Wash with warm H20 and detergent. (3 ) Rinse with H20 and spray sanitizer {30 to 50 ppm). (see Table 5) 45 High bacteria counts on end-of-line products may warrant an in-plant microbiological survey unless the local officer can determine the cause. All deficiencies not specified previously may be recorded on the FPR. Plant classification rating to be given based on overall plant operation and equipment. (/) LLJ 0::: :::::> c::i LLJ u 0 0:: ,...-j c... ,...-j ,...-j LLJ '-!:l c::( 0::: 0 I- (/)

Cl -' 0 u - 112 -

COLD STORAGE PROCEDURES ======Cold storage establishments which are used for storing frozen fish products come under Schedule IV of the fish In~pection Regulations. Schedule IV shall be applied to cold storages which are an integral part of the fish processing operation and are covered by the Certificate of Registration issued for the establishemnt. Until such time as amendments (1975) to Schedule IV have been promulgated and implemented with cooperation of Fisheries Council of Canada and other members of the fishing industry, no action will be taken as a result of cold storage establishments failing to comply with~ sections of Schedule IV. Instead, field inspection officers will carry out routine inspection of freezing equipment performance and regular monitoring of cold storage per­ formance in registered plants. - 113 -

TABLE 5 - LIST OF ACCEPTABLE MATERIALS AND COMPOUNDS

Lists are available by contacting Plant Services at the F.W.L nrrip

- 114 -

APPROVED PEST CONTROL PROGRAM Section 11 of Schedule 2 of the Fish Inspection Regulations states that an "approved rodent and insect control program shall be maintained in

11 every establishment • Where pesticides are used, their application shall be made under the supervision of a responsible operator using proper equipment in a manner that prevents contamination of fish. Only approved pesticides as listed in Table 5 should be used. Rodents and insects are potential public health hazards. Rodents may carry diseases. most of ~lfhich are transmitted to man by contamination of food with rodent excreta and urine. The common house fly is a carrier of diseases caused by cro-organisms. There is also the danger of product contamination with rodent hairs or droppings and insect fragments. The following steps should be followed by plant management in carrying out a pest control program.

1) identify the problem.

2) delegate responsibility for solving the problem.

3) attempt to control problem.

4) follow up on results - (repeat as necessary).

1) Identifying the Problem A. General Detection i) Visible: Rodent Insect Bird Other a) droppings a) droppings a) droppings a) droppings b) damage b) damage b) damage b) damage c) nesting c) cases c) nesting c) casts, tracks d) trails d) egg cases d) spi 11 ed feed d)trails e) trails - 115 -

ii) Invisible Rodent Insect Bird Other a) UV Light a) Flotation a) Sound a) UV Light b) Flotation b) Sound b) UV 1i ght b) Odor c) Sound c) Use of c) Sound d) Odor flushing chemicals e) Use of d) Odor flushing chemicals B. Specific Areas to Look for Insects 1. Insect-0-Cutor trays 2. Vacuum Cleaner Receivers 3. Primary air filter screens 4. Outside window screens 5. Garbage dock 6. Flys go to cool areas, light 7. Crickets, Roaches go to warm, moist areas 8. Electrical switch gear, favorite for Roaches 9. Water treatment areas 10. Pallets 11. Crevices, openings a) may need to use flushing compound 12. Boiler rooms, engine rooms, cafeterias, locker rooms C. Specific Areas to Look for Rodents, Birds, Domestic Animals 1. Seldom used storage areas and equipment 2. Foundation walls 3. Pallet yards 4. Outside harborage areas 5. Rub marks - body contact 2) Delegate Responsibility for Pest Control Pests must be controlled by responsible operators in a safe manner. Ensure only approved chemicals are used and all directions for use are explicitly followed. Take all possible safety precautions. If chemical pesticides are being sprayed the operator should wear a mask, rubber gloves, rubber boots and coveralls which should be cleaned after each use. If any chemical is spilled, cleanup should be initiated immediately and thoroughly. Hot water bleach or lime are effective in cleaning up chemical spi 11 s. - 116 -

No chemical pesticides may be used in a plant area where food is exposed. All areas that may later contact fish must be thoroughly rinsed with potable water before fish may be uncovered or brought back into the area. Any --"- i nsecti ci de with long-lasting residuals or continuous application apparatus are not permitted in food processing areas due to the fact that flying insects may fall into the product while under the effect of such pesticides. The use of many chemicals requires the applicator to have a specific license which may be issued by Agricultur1~ Canada. In extreme cases, professional pest exterminators may be required to rid a plant of its problems. Always check with local, municipal, town or city health officials prior to use of pesticides, insecticides or any chemicals that may be injurious to public health for approval prior to use. 3) Control A. One method of regulating pest control is to establish definite, increasingly tighter zones of defense. For example: a. Start with "de fence". Zone one should be a line furthermost from your buildings. 1. spring traps and bait stations, 40 feet apart 2. residual sprays 3. open area of 25 feet minimum, free of cover 4. change baits often use water bait or lettuce in summer 5. larvicides may be used for areas of standing water. b. Zone two -- next logical line of demarcation such as parking lot, roadway, etc. 1. Spring traps, protected with 1/2 cans - 117 -

2. bait stations, 20 feet centres 3. residual sprays 4. tracking powders 5. domestic animals must not cross this zone 6. area for pre-baiting techniques c. Zone three -- outside building walls, bait stations on 40 feet centres; inter-space with traps on 40 feet centers. 1. heavy residual ·sprays, up to 30 feet, out 10 feet. 2. tracking powder 3. thermo fog d. Zone four -- internal 1. spring traps on 20 feet centers 2. automatic traps, 30 feet centers and moved often 3. automatic aerosol dispensers, lunch rooms, offices, attic and locker rooms only 4. filtered air, pressurizing builing 5. vestibule or air lock 6. insect-o-cutors 7. white aisles, good storage practices 8. operator education e. Zones of defence -- making them work 1. Keep them active (a) fresh bait (b) change or rotate type of bait, attractant ( c) protected baited spring traps (d) rotate residual use (e) be alert to activity developing - 118 -

(f) use prebaiting techniques (g) change fogging hours and areas to suit demand; pests are not static 2. Pay attention to details (a) pallets (b) pallet transfer (c) harborage must be controlled (1) structural; double walls, tile runs, false cei1ings (2) incidental; equipment, fixtures, lockers, etc. (3) temporary; storage, stored equipment (d) fixed runways

(1) rodents highly suspiscious (2) use tracking powder (3) pre bait (4) treat, wait, treat, test, trap (e) look for the "un-obvious" (1) load levelers (2) foundation drains (3) gutters (4) screened areas, flashings (5) elevation not always protection

rodents jump -- rats can 11 glide" 1i ke a tree squire 11 , for up to 150' free fa 11 and hit the ground running. B. Specific Control Methods Detailed methods of control will depend on local conditions. Control methods should not disrupt ecological balances of nature. - 119 -

i) Rodents Control may be accomplished by a) suppression or b) destruction a) Suppressive measures are those designed to keep rodents from food and water supplies and to keep them from gaining access to places where they can breed. the following are examples of suppressive measures: 1) Food should be stored in rodent-proof buildings or containers. 2) Garbage should be placed in metal cans with tight-fitting covers. 3) Refuse disposal systems employing sanitary fill or incineration will discourage rodents. 4) All inedible portions of fish, unless immediately processed, should be made inaccessible to rodents. 5) All new construction should be rodent-proof. 6) All existing buildings should be inspected carefully. All openings large enough to admit rodents should be covered with metal sheeting or heavy screening. Rodent-proof screened drain outlets are also required. 7) Old lumber and rubbish piles should be removed. Good outdoor maintenance is required. b) Destructive measures are the poisoning and trapping of rodents. Rodents may be poisoned, the most effective toxin being warfarin. These chemicals are toxic to humans and food adulterants. To prevent other animals and children from accidently consuming poison, the compound should be carefully placed and one may use a rodent baiter which is a sanitary, tamperproof bait station. (One type is manufactured by Bell laboratories, Inc., Box 5133, Madison, Wisconsin, distributed by Poulin's Exterminators at 24 Marion Place, Winnipeg.} Poulin's recommends one bait station every 30 - 50' for rats and every 10' for mice. The bait should - 120 -

be checked every 2 to 3 days and replenished as it disappears. Once the bait level remains constant then the problem has likely disappeared, or a new solution is required.

Poison-food for rats should not be stored where it may absorb bad odors as rats will not respond to bait that smells of gasoline or other repugnant fumes.

Squirrels may be caught in 11 1i ve" or "tender" traps and then transported to a safe distance from the plant. Rozal poison, commercially impregnated into grain may be mixed with peanut butter if the problem is too great. ii) Birds Birds are serious contamination problems as their dropping harbour salmonella and other bacterial of public health significance. Birds may be controlled by using "live" traps with bait. Lights and noise-making devices won't curb them for long as th~y will become accustomed to the commotion and return in greater strengths. Other than poi?oning, there are two methods of discouraging birds. Areas in plants where they like to roost may be painted with Tanglefoot, a polybutelane non-toxic substance. Birds do not like the feel and avoid lighting sticky compound. The Nixalite Co. of America manufactures roosting deterrents for birds It consists of sharp prongs of uneven lengths attached at various angles to a base wire. This is place where the birds like to roost and can be easily made with wood strips and sharp nails or wire. iii) Insects Ensure all food is covered or removed before spraying any chemicals and that food-contact surfaces are thoroughly rinsed with portable water - 121 -

before processing co!l1l1ences. The use of insecticides should augment, not replace, the standard methods of sanitation such as the adequate disposal of offal, effluant and sewage. Pyrethrum is the co1TUTion active ingredient in most of the insecticides recorrmended for use in food processing areas. This chemical leaves very little or no residual and application must be repeated whenever the problem presents itself. Wind screens set up a barrier of fast-moving air to preclude entry of flying insects. These fans are generally quite costly and not always effective. Insec-o-cuters will help to control the flying insect problems if placed, mounted, and maintained correctly. They will not stop insects from breeding or from entering the building. Good housekeeping practices are also important in pest control. 4) Follow-up There is no such thing as pest-proofing a facility. Recovery rate of pests if fantastic. A 90% kill of rats, with no follow-up treatment, will result in 2 - 6 % return rate of the original population per month. Original level will be reached in 30 months and due to natural selection of original survivors the population will be more resistant than ever. Therefore, pest control must be an ongoing duty and concern of all plant personnel. The extent of control needed will vary according to the type and .severity of problems encountered.

- 122 -

Plastic Tub and Wood Box Storage

Outside storage of tubs and boxes permits exposure to rain and other elements which may result in mold growth and deterioration of wooden boxes. Tubs and boxes can pro vi de a source of rodent harbourage and contamination by bird excreta which may lead to the presence of bacteria of public health significance and may be transmitted to the product, yet not detected by routine inspection of containers. Industry does not have the expertise or necessary equipment to satisfactorily clean or disinfect wooden boxes brought into the ant from outside storage. Many plants using wooden boxes have started switching to the use of plastic tubs. These generally require less storage space and are more easily c 1eaned. However, tubs or boxes contaminated with rodent or bi rd dropping cannot be judged to be satisfactorily cleaned by removal of excreta fo 11 owed by washing and must also be disinfected. Disinfecting will _g_robably kill most bacteria om the tubs but will not

be very effective for wooden boxes due to the porous nature of the wood. The absence of visual signs of contamination following cleaning is i nsuffi ci ent, and cleanliness must be verified by 1aboratory analyses especially where contamination by animal excreta is evident in tubs or boxes. Only new, clean and sound containers for storage, packing and shipping of fish is permitted. However, within a province, used boxes and tubs may be shipped between plants if they are clean and sound and may also be shipped

between provinces if they are clean and sound and stay within the Region. To ensure tubs and boxes are clean a protection facility of some kind is required to prevent contamination by their direct exposure to pests and weather. - 123 -

Ideally all boxes and tubs should be kept in the plant away from the processing area, or in any building that complies to the construction and operation requirements of the FIR. Note: Satisfactory box construction and tub and box storage areas are a requirement for new plant registration and evidence of satisfactory protection of containers is a requirement for continuing registration of existing plants. The following are minimum requirements for 5 of the parameters involved for tub/box storage areas constructed as separate facilities: 1) Floor - cement or wooden platform either directly on ground or with

11 11 a platform at least 18 - 20 from the ground. Boxes must not rest directly on ground. 2) Walls - wood, or wire mesh (up to 1/2 inch) screen, or heavy tarp. 3) Ventilation - fan or screened windows in enclosed buildings. 4) Exclusion of animals and birds - keep gate or door shut. 5) Surrounding area to be kept clear from long weeds or grass, which could harbour pests. - 124 -

An officer may not permit the use of boxes or tubs if he has reason to believe that there are dirty, unsatisfactory containers within a lot. He may permit industry to segregate out acceptable tubs or boxes and re-submit any such acceptable containers for inspection prior to using them. Where there are complaints from plant managers that tubs are being received from the source contaminated, the containers, may be detained by the inspecting officer. A notice of detention will be written and given to the plant manager and a copy sent to the source management. The detention notice serves as documentation for the plant manager that the tubs were received · directly from the source in unsatisfactory condition. Where the containers are dirty but production is such that there would be a shortage of containers if the unsatisfactory ones were returned they may be used when necessary if they are thoroughly cleaned. Where there had been evidence of bird droppings or animal contamination the containers must be disinfected. The local inspector will notify the management in writing that a problem exists and that remedial action by the plant sending unsatisfactory tubs is necessary in order to prevent any further occurrences of this type. II V') I-z c:( _J CL w V') 0 CL 0::: ::::> CL ,_..I I- _J ~ :2: - 125 -

MULTI-PURPOSE PLANTS

Multi-purpose plants are plants where commercial processing of fish and other product(s) occurs in the same establishment. Establishments which are to be used for purposes other than fish processing require permission for such usage from the DepartmE~nt. Other appropriate agencies which may be involved must also be contacted by the plant operators. A ·ietter is to go to the fish plant owners and managers to inform them that different products may be processed in the same plant as long as the following conditions are met to ensure sanitary fish processing operations:

i) Receiving and holding areas in plants processing fish and other products at the same time, to be completely separate to prevent possible bacterial and physica1l contamination of fi:sh by dressed animal carcasses. Our concern is linked to contaminated and/or diseased carcasses being thrown on same floor where fish in tubs are being held, awaiting processing.

ii) Wet working/processing areas in plants processing fish and other products at the same time, to be completely separated for same

reasons as in (i). The processing (cutting, etc) of animal carcasses in same immediate area as fish processing is not considered a sanitary operation.

iii) Cold storage areas can be separated by way of partitioning off freezer areas. iv) Plants may operate as multi-purpose in lieu of requirements as illustrated in i) and ii) provided that: a) processing of fish is carried out a different time from other products; b) other products - 126 -

are not being stored or processed with the fish except as in iii); and c) provided that the plant is thoroughly cleaned and sinfected prior to processing fish.

Field officers should be fully aware of opening and closing dates es in an area and should ensure that proper cleanup procedures occur before start-up ring shing operations.

127

WATER/ICE ACTION REPORT FOR 840412 ------

[I ISIR ICI; MAN Il'OBA plant plant water saaple result follow-up ice sa111ple result follow-up nu111ber name date date date di ate YYHMDD YYHHDD YYMliDD YYiiMDD 31001 F.F.M.C. WINNIPEG 830511 s 830913 s 31003 DENBE1GH POINT PACKERS 830608 s 830608 s 31006 EASIERVILLE FISHERMENS COOP 830119 s 830119 s 31007 FISH SERVICES LID. 830510 s 830119 s 31009 BOOTH FISHERIES CANADA CO.LTD. 830922 s 830119 s 31010 NEPIUNES FISHERIES 830518 s 830303 s 31011 !N[IEPENDENT FISH CO.LID. 830518 s 830303 s 31016 EDI!YSTONE FISHERMENS COOP 830118 s 830118 s 31018 GRAND RAPUIS FISHERMENS COOP 830609 s 830609 s 31019 LAKESIDE FISHERIES 830119 s 830119 s 31020 L. MANITOBA COOP FISHERIES-OP 830119 s 830126 s 31021 L. MANITOBA COOP FISHERIES-SA. 831220 s 831220 s 31023 L MANITOBA COOP FISHERIES-SL. 831220 s 831220 s 31024 LAKE ST.MARTIN COOP 831220 s 831220 s 31025 LOG CABIN PACKERS 830110 s 830118 s 31028 MA!KO!ilSKI PETE -IrUCK BAY 830119 s 830119 s 31029 i!ICHALOI E. 030119 s 830217 s 31030 ll!ORIHEND PACKERS 030216 s 830216 s 31031 PRINCESS HARBOUR FISH AGENCY 030614 u 830621 830628 s 31033 SIGURDSON K. 840110 c s 831221 '"' 31035 SKOWNAN FISH AGENCY 830119 s 830119 s 31037 TRAVERSE BAY COOP 830928 u 831013 830928 u 831013 31043 BIG BLACK RIVER COOP 830614 s 830614 s 31044 DAUPHIN RIVER FISH AGENCY 840126 s 831220 s 128

WATER/ICE ACTION REPORT FOR 840412 ------DISTRICT: HANITOBA plant plant water sa1ple result follow-up ice sample result follow-up riu1ber nae date date date date YYHHDD YYHHDD YYHHDD YYHHDD 31047 DOW BRA[I 831221 s 831221 s 31048 FAIRFORD FISH AGENCY 840308 s 840308 s 31049 F.F.H.C. BERENS RIVER 830915 u 830922 830915 s

31051 F.F.H.C. GEORGES ISLAND 830614 u 830621 830614 u 830621

31053 F.F.H.C. HC BETH 830913 u 830920 830913 u 830920 31055 F.F.H.C. WARRENS LANDING 830628 u 830705 830628 s 31079 KJARTANSON J.R.-AHARANTH 831221 s 831221 s 31095 NORWAY HOUSE FISHERHENS A.TI 831221 s 830614 s 31102 ROUTHIER H OR H. 840114 s 831221 s 31111 WAN IP IGOW COOP 830928 s 830928 s

31112 WINNIPEGOSIS FISHERHENS CP-G.H 830719 u 830726 830719 u 830726 31115 GOODMAN'S LANDING PLANT 830616 s 830629 s 33001 F.F.H.C. LYNN LAKE 830414 s 830414 s 33002 F.F.H.C. LEAF RAPIDS 830711 s 830711 s 33003 F.F.M.C. WABOWDEN 830621 s 830621 s

33004 MATKOWSKI PETE -KISSEYNEW L. 830623 u 830630 830623 u 830630 33015 F.F.H.C. THE PAS 830607 s 830607 s 33044 F.F.H.C. ODE! R. 830712 s 830712 s 33077 HOOSE LAKE FISHERHENS ASS'N HL 830910 s 840302 s 33086 NORWAY HOUSE FISHERHENS A.PLGP 830614 s 830615 s 129

WATER/ICE ACTION REPORT FOR 840412 ------[tIS!RICI: ALBERTA plant plant water sa1ple result follow-up ice sample result follo1i1-up nu111ber name date date date date• YYHttDD YYHttDD YYMMDO YYMMllD

12004 WEST END PACKERS &PRDr!UCERS 830309 s 13004 COLD LAKE FISHERHENS COOP 830324 s 830324 s

13005 NORTHWESTERN FISHING COOP 830309 s 830309 s

1300& LAC LA BICHE FISHERHENS COOP 831004 s 831004 s

13007 HIGH ARCTIC MARKETING CORP. 840314 s 831004 s

13008 F.F.M .C. BROOKS 840315 s 840315 s 130 -

WATER/ICE ACTION REPORT FOR 840412 ------[llSTRICT: SASKATCHEWAN ...... plant plant water sasple result follow-up ice sample result follow-up nu1ber name date date date date rntttDD rntttDD Y'ittttDD YYttttDD - 22005 REINDEER L.FISHERHENS COOP-KIN 830817 s 830817 s

23002 WAITE FISHERIES 830719 s 830719 s 23003 WAITE AND COHPANY 831230 s 831230 s - 23004 F.F.tt.C. LA RONGE 830802 s 830802 s 23013 NORTHLAND PROCESSORS 830911 s 830802 s 23014 PELICAN NARROWS COOP 830927 s 830927 s 23015 CANOE LAKE FISHERIES 830622 s 830622 s 23016 OSSEY FISHERHENS COOP(DESCHAttB 830915 s 830915 s 23017 FISHERIES &OCEANS HOBILE 831017 s 831017 s 23019 WEST BOUNDARY COOP 840313 s 840313 s 23026 CUMBERLAND HOUSE COOP 830708 s 830624 s 23034 DORE LAKE FISHERHENS COOP 830921 s 831230 s 23043 BIG ISLAND COOP (ILE A LA CROS 840110 s 840110 s 'i 23060 NORTHLAND FISHERHENS COOP 831011 s 831011 s 23085 LALOCHE/TURNOR FISHERHENS ASSN 830913 s 830913 s 131

WAIER/ICE ACTION !REPORT FOR 840412 ------DISTRICT: N.W.T. plant plant water sample res•.Jlt follow-up ice sa111ple result follo~J-up number name date date date date YYttHDD YYl1t!DD YYMHDD YYMHDD

51001 F.F.M.C. HAY RIVER 830808 s 830808 u 830815

51002 F.F.M.C. SIMPSON ISLANDS 830808 s 830823 u 8308310

51003 F.F.H.C. WOOL BAY 830823 u 830830 830823 u 83083:0

51004 F.F.M.C. MORRAINE BAY 830823 s 830823 u 830901 51005 KAKISA LAKE FISHERY 830614 u 830621 830614 u 83062:1

53001 ULU FOOIIS 930804 s 83080·4 s

53002 HARRISON J. 830803 u 830809 830804 s

54001 ILKALU PLANT 830824 s 830824 s

54002 BYRON BAY - 830829 s 83082~~ ILJ 830906

54008 WELLINGTON BAY FISH PLANT 830824 s 83082~~ u 830906

58001 ISSATIK COOP 830826 s 830826 s

58010 ARCTIC TERN - I.EECHERK VESSEL 830825 s 830826 s

58012 WHALE COVE PLANT 830803 s 830826 s

58013 CHESiERFIELD INLEI PLAN! 830803 s 830826 s - 132 -

FIELD PROCEDURES - WATER & ICE SOURCES Plant registrations will not be granted without a satisfactory bacteriological water and ice report. Water and ice samples should be taken con-currently with a team survey. Samples for both water and ice should be taken once each operating period or every six months whichever term is longer. If a problem presents itself, sources should be monitored more closely. Water obtained directly from municipal source should be sampled at least once each year. If water and ice sample is unsatisfactory, the District should immediately contact the plant operators and suggest a means of rectifying the situation (e.g. extending hose further into lake or utilizing source away from obvious causes of contamination) and include these suggestions on the Bac­ teriological Report sent in to Regional office. If an unsatisfactory sample is analyzed while the inspector is still present he should investigate and suggest corrective measures, and ensure that the product coming from that plant is carefully monitored. Districts are to revisit the plant as soon as possible and resample the water in the same operating season within a reasonable time frame. If problems persist, it may benefit the plant to have an inspector present for a day or two so that he may be able to discover the source of con­ tamination. Chlorination of water and/or ice supply may be necessary and batch chlorination should be practiced unless a gas chlorinator is warranted. If the water is grossly contaminated, an alternate source must be found immediately. - 133 -

In all cases where water/ice contamination sources cannot be resolved and bacterial counts reduced to acceptable levels, Districts should contact

Regional Headquarters to request participation ~ the Regional Microbiologist and Plant Services Section for in-plant and water source surv12ys. All plants processing fish for the export market must have acceptable water and ice sources.

1. For water supplies used by registered plants, plants undergoing registration, and all municipal water, the coliform levels should not be greater than 2/100 ml water analyzed.. For water supplies used by other plants not included in above, the co"liform levels should not exceed 10/100 ml water analyzed.

2. For all ice supplies used by our fishery operations, the coliform levels should not be greater the 10/100 ml melted ice analyzed.

NOTE: The final results of water/ice analyses will be based on the geometric means of samples analyzed, ie. 3 water or ice samples. For the geometric averaging of the data, primary product inspectors are to be provided with either log tables or scientifc calculators. ii Field personnel involved with water/ice analyses have the option of withdrawing one sample of water/'ice instead of the historical 3 sample, and undertaking triplicate analyses of the one sample withdrawn. The final reportable results will be the geometric average of these triplicate analyses. If one sample is to be withdrawn, larger sample bottles, ie. 1000 ml, are to be used. When water samples are collected there should be sufficient head space in the container to allow manual shaking 25 tim12s through an arc of one foot just prior to analys12s. This is very important if triplicate analyses are to provide comparable and accurate results. If there is sufficient waiting period between triplicate analyses, ie. slow filtration in the case of MF analyses, the water sample should be shaken again prior to subsequent analyses.

iii Inspectors obtaining water samples are to obtain same from a primary outlet such as a tap. Artificial ice is to b12 sampled from newly manufactured ice (prior to handling with shovels, etc.). A natural ice source is to be sampled from ice washed thoroughly with potable or sterile water. Water samples may be taken from other than a primary outlet in order to determine levels of contamination for chlorination purposes. Ice samples may be taken from other than newly manufactured or washed natural sources to determine lev12ls and sources of contamination (eg. shovels). Any such samples may be analyzed in addition to primary sources and must be clearly indicated on the bacteriological reports. - 134 -

iv It is essential that stringent aseptic techniques be used when obtaining water/ice sample for analyses.

Geometric Means of MF Field Water/Ice Results

Thanks to H. Ballon and K. Scott there is a simple method of obtaining geometric means of water/ice results - without using log/antilog tables. The following will thus explain this improved method. Please review same with field personnel and comment if you so desire.

The Geometric Mean of several water/ice sample results is: n ______./s i x S2 x Sn

where n is the number of samples and S1 , S2, etc. are the individual sample counts. This is usually calculated with a slide rule, scientific calculator or logarithm and antilogarithm table, the latter involving longhand addition and division which is quite involved.

A simpler method is to use a 'look-up' table with columns listing the 'multiplications' of the plate counts, and their corresponding geometric means, for any number of samples from 3 to 6. For example, if we had 3 water/ice results of 3, 5, and 7, the multiplications would be 3 x 5 x 7 = 105 (done by hand or simple calculator). Looking down the 'plate count multiplication' colurm for 105, we find that 100 is the nearest value. Since we had 3 samples, we would look in the 3 column opposite 100 and find 5 as the answer.

When the multiplication is very large, and between the listings in the plate count column, we can estimate an answer by interpolation. For example, a multiplication of 275,000 for 3 samples would be 65 in the~ column.

Note: If all sample counts were 0 (zero), the multiplication as well as the geometric mean would also be zero. However, if one or more but not all of the counts were zero, the normal multiplication would again by zero, giving an invalid result. In such cases, change each 0 to 1 and multiply as usual. For example, counts of 0, 0, and 20 become 1, 1, and 20, giving a multiplication of 20 (not O) and a geometric mean of 3. 135 Plate count Number of Samples Plate count Number of Samples Multiplication 3 4 5 6 Multiplication 3 4 5 ------6 1 1 1 l 1 1,250 11 6 4 3 1,500 11 6 4 3 2 1 1 1 1 2,000 13 7 5 4 2,500 14 7 5 4 3 1 1 1 1 3,000 14 7 5 4 3,500 15 8 5 4 4 2 1 1 1 4,000 16 8 5 4 4,500 17 8 5 4 5 2 1 1 1 5,000 17 8 5 4 5,500 18 9 6 4 6 2 2 1 1 6,000 18 9 6 4 6,500 19 9 6 4 7 2 2 1 1 7,000 19 9 6 4 7,500 20 9 6 4 8 2 2 2 1 8,000 20 9 6 4 8,500 20 10 6 5 9 2 2 2 1 9,000 21 10 6 5 9,500 21 10 6 5 10 2 2 2 1 10,000 22 10 6 5

13 2 2 2 2 12., 500 23 11 7 5 15 2 2 2 2 15,000 25 11 7 5 20 3 2 2 2 20,000 27 12 7 5 25 3 2 2 2 25,000 29 13 8 5 30 3 2 2 2 30,000 31 13 8 6 35 3 2 2 2 35,000 33 14 8 6 40 3 3 2 2 40,000 34 14 8 6 45 4 3 2 2 45,000 36 15 9 6 50 4 3 2 2 50,000 37 15 9 6 55 4 3 2 2 55,000 38 15 9 6 60 4 3 2 2 60,000 39 16 9 6 65 4 3 2 2 65,000 40 16 9 6 70 4 3 2 2 70,000 41 16 9 6 75 4 3 2 2 75,000 42 17 9 6 80 4 3 2 2 80,000 43 17 10 85 4 3 2 2 85,000 44 17 10 7 90 4 3 2 2 90,000 45 17 10 7 95 5 3 2 2 95,000 46 18 10 7 100 5 3 3 2 100,000 46 18 10 7

125 5 3 3 2 125,000 50 19 10 7 150 5 3 3 2 150,000 53 20 11 7 200 6 4 3 2 200,000 58 21 11 8 250 6 4 3 3 250,000 63 22 12 8 300 7 4 3 3 ·300,000 67 23 12 8 350 7 4 3 3 350,000 70 24 13 8 400 7 4 3 3 400,000 74 25 13 9 450 8 5 3 3 450,000 77 26 14 9 500 8 5 3 3 500,000 79 27 14 9 550 8 5 4 3 550,000 82 27 14 9 600 8 5 4 3 600,000 84 28 14 9 650 9 5 4 3 650,000 87 28 15 9 700 9 5 4 3 700,000 89 29 15 9 750 9 5 4 3 750,000 91 29 15 10 800 9 5 4 3 800,000 93 30 15 10 850 9 5 4 3 850,000 95 30 15 10 900 10 5 4 3 900,000 97 31 16 10 950 10 6 4 3 950,000 98 31 16 10 1,000 10 6 4 3 1,000,000 100 32 16 10 I~)

Raw Comments/Action

<3 MPN/100 ml Satisfactory, No treatment N/A Satisfactory required.

~-1n MPf\i/lnn ml ...,, .lb V' I II I' f .L.VV 1111 Simple chlorination • <3 MPN/100 ml

10-100 MPN/ Simple or gas chlorination. <3 MPN/100 ml Satisfactory 100 ml

100-1100 MPN/ Filtration and/or ozonation <3 MPN/100 ml Satisfactory 100 ml and chlorination or alternate source. 1100+ MPN/100 ml None premitted. N/A Un satisfactory Alternate source required

*Note: If treated water is still unsatisfactory, further treatment, as progressively outlined in the column "Type Treatment Required", is necessary. B) cal Count

R

<3 MPN/100 ml Satisfactory. No treatment Satisfactory required. 10-100 MPN/100 ml Simple or gas chlorination Check equipment required if machine-made and \'later source ice. Alternate location ( <3 MPN/100 ml) if harvest source. Alternate location if natural ice 100-1100 MPN/100 ml Diltration and/or ozonation Check equipment and chlorination if machine­ and water source made. Alternate source of Alternate location water and/or ice. if harvest source 1100+ MPN/100 ml None permitted. Unsatisfactory Alternate source ...... required w -....J

*Note: If treated ice is still unsatisfactory, further treatment, as progressively outlined in the column "Type Treatment Required", is necessary. II (/) >- w > er: =:::> (/)

_J < ,_,u <.!l 0 _J 0 ...... 0:: LL.I I- u

A GUIDE TO ASSIST FIELD STAFF IN THE COMPLETION OF ======IN-PLANT BACTRIOLOGICAL SURVEYS* ======In-plant bacteriological surveys are used to trouble-shoot and resolve sources of contamination. They will normally be conducted wh1::n bacteriologically unsatisfactory end-of-"line products are being produced by a plant. Some of the reasons for conducting an in-plant bacter'iological survey in domestic plants are as follows: 1) SPC values over 250,000/g for raw products or over 100,000/g for cooked products, 2) Eschericheria coli in excess of 400/lOOg. 3) Presence of coagulase positive staphylococci. 4) Presence of Salmonella, Shigella, EEC, etc. The main purpose of any swab survey is to determine the point or points at which the product is contaminated and to assess the effect of remedial measures as these are introduced. The swab methodology and rat i ona ·1 e of same is outlined in parts 12 and 13 of the Standard Procedures Manual for Bacteriological Analyses. The use of the swab technique in performing in-plant bacteriological surveys can be conducted in either a ~litative or a quantitative manner. The latter method, making use of a 211 x 5" stainless steel template to more precisely enumerate bacterial numbers per unit area of surface swabbed, can usua'lly pinpoint a contamination problem .. However, the use of either one of these two methods (along with in-line/end-of-line product sampling) is *As performed by laboratory personnel. Regional responsibility - Salmonella. Shigella, Clostridium, E.E.C. and organism identifications. Districts perform analyses for SPC's, Coliforms, Faecal colliforms, E. Coli, and Staphlococci coagulase positive. - 139 -

acceptable. The method used may depend on a number of factors such as the type/location of a fishery operation, type and/or extent of a contamination problem, type of product, and the results of a visual plant survey as performed by primary product inspectors as part of their routine duties. As soon as a bacteriological problem is encountered, visual inspections should be carried out at assess plant operations. Also, the plant's water supply should be immediately checked for sufficient pressure and washing efficency in all washing operations along with chlorine and coliform determinations. The use of abundant amounts of ice and/or refrigeration methods during holding, packing, and shipping procedures should be encouraged to minimize any increases of bacterial numbers from the time the fish are caught and processed to the final end-of-line product. All personnel should be aware of the rationale behind such a survey especially since they will be working together to solve a common bacterio­ logical problem. A better understanding by all personnel involved of the swab methodology, reasons for conducting in-plant bacteriological surveys, various types.of fishery operations and product contact surfaces that may be possible contamination sites in these operations will lead to a more efficient coordination of efforts to ensure that fish and fish products are of high quality, have a longer shelf life, are free of organisms of public health significance and are safe for human consumption. Note: Product contact surfaces are equipment surfaces that product comes into contact with throughout the fish flow route (harvesting-packing-processing) and represents possible contamination sites. When applicable and practical, in-line as well as end-of-line samplings should be performed at these surfaces at these same sites. Personnel handling the products should also be swabbed - i.e., gloves, hands. - 140 -

The type of analyses performed on in-line/end-of-line product, swab samples, will depend on the contamination problem - i.e., high SPC's, E. coli, coagulase positive staphylococci, Salmonella/Shige11a, etc. Generally, initial emphasis should be placed on determining bacteriological counts on the incoming fish along with estimating the efficiency of a product washing operations. The use of a 2" x 5" template for swabbing procedures will yield a more accurate picture of a contamination problem. To determine the efficiency of a plant's product washing procedure, e template must be used (in the swab technique) to quantitate standard plate counts (not fecals) on at least ten fishe~y samples - before and after passing through the washer. The opposite sides of each of these fish are swabbed before and after washing. Sampling Times (dependent upon type of operations) All sample stations are to be numbered and named. Samples should be taken: 1) prior to operation, 2) at least one hour after the operation has commenced, 3) during the morning break (before equipment washing procedures), 4) after the morning break, 5) during lunch break (before equipment washing procedures), 6) after lunch break, 7) after the final clean-up operations at the end of the day, 8) consecutive, follow-up surveys, - times as outlined above. - 141 -

Examples on In-plant Microbiological Surveys Where a microbial problem has been encountered in an end-of-the-line sample and a microbiological survey is required in order to locate the source of contamination, a pattern should be followed tracing the flow of that problem product through the entire process. The process flow indicated in the accompanying diagram may aid those conducting such surveys. Swabs and/or in-line samples should be taken along the processing route in locating the source of the problem as follows: [l] or [2] fresh fish being or recently received. [3] or [4] fresh fish transferred to pre-processing or awaiting processing. (A, B or C) [5] [6] fresh fish after scaling (line 1) and before washing [{6) where there is not continuity of 5-7].

[7] [5B] [5C] fish after washing to determine effect of sprayer or washers. [8] [6B] [6C] fish after handling by filleters, trimmers or splitters. [7B] [7C] fish after running through a skinner or deboner. [9] [88] fish after washing to determine the effectiveness at the washing stage. [10] fish that has been coated with a solution such as po lyphospate. [11] [8B] [BC] fish that has been handled by a weighman or panner.

The fish at this point is ready for fresh shipping or for further processing such as freezing. Samples should be taken in such further processing (freezing) as indicated by the arrows (see flow chart). - 142~ -

The effectiveness of cleanup operations can be determined following the flow in processing sequences by taking swabs of the various pieces of machinery, cutting boards, knives, glovesi, tables and process containers.

Swabs should be taken before, during, and after processing operations

(especially before startup in the first shift and after cleanup during breaks and between shifts).

Water, ice, glazing and coating solutions or any other materials that come in direct contact with fish at any stage during the process should be sampled. ---1

- C'> ~" ~ ';::; I h'J ,. I " I "?.tr, ~ L''l \ -:.;-.,. r WAl>VP ·o: ~RfA' l ! I! t 2 ----l41il - . . 7 > 1 \ ---- L 'I COLO

I A I !~ ! ~' ll ! \ ll I \ ' I 1 \ l ij]J9 \ ~ ll...! i ...... T w :r: f- - 14-4 -

THE MEMBRANE FILTER TECHNIQUE INTRODUCTION The membrane-filter technique has been well documented and accepted as a standard method for the bacteriological analysis of water and waste water ("Standard Methods for the examination of Water and Wastewater", lastest edition). Simply put, a water sample is passed through a bacteria-retentive membrane filter, and the bacterial cells in the water sample are quantitatively removed and retained on the filter surface. The filter is then

placed on an appropriate nutrient medium, and the nutrients diffuse by capillary action through the pore structure of the filter and reach the surface, where the individual cells are nourished and grow into visible isolated colonies which can be counted without the aid of a high magnification apparatus.

SCOPE AND APPLICATION Membrane filter methods are preferred over MPN or other techniques, where applicable, because of the following advantages.

ADVANTAGES a) One of the primary advantages of this method is its speed. D1::finitive results for total and faecal coliforms can be obtained in 22-24 hours, whereas 48-96 hours are required for the multiple-tube fermentation method. b) Considerably larger, more representative water samples can be examined than with the MPN. With water of low bactE!rial density such as finished waters, larger sample aliquots can be used to enhance the reliability of the results. - 145 -

c) The precision and accuracy is greater with the MF than the multiple-tube technique because the former makes a direct count of colonies per unit volume. In general, microbial synergisms/antagonisms do not affect the counts obtained by the MF (as compared to the MPN procedure) since individual cells caught on the surface of the membrane are separated from one another enough as to not interfere with each other's growth - in either a positive or negative manner. d) The MF method represents savings in time, labour, space, supplies and equipment. e) Because of the portability of a commercially available 11 field kit" the MF procedure is very practical for field studies. This MF procedure is especially advantageous over the MPN technique in the remote areas where it is often impractical or impossible to bring water samples back to the home-based lab in time for analyses. The use of the portable MF kit in the field allows field personnel to rectify problem water supplies on site, the following day and water samples were collected and filtered; also, the MF kit can be very useful in the field to determine plant contamination sites via in-plant bacteriological swab surveys.

LIMITATIONS Although the majority of water samples can be tested by membrane filtration, there are some limitations with certain water samples and with the membrane filters themselves. a) Some water samples may contain large amounts of colloidal materials or solids such as iron, maganese or alum floes or clay. Other samples may contain high numbers of algae. These substances can clog the membrane filter pores and prevent filtration If the bacterial counts of such - 146 -

samples are high, a smaller volume or aliquots of a higher dilution of

sample must be made to minimize the E~ffect of sample turbidity ere a re now commercially available pre-filters which can be used to remove much of

the turbidity without substantially reducing bacteria 1 numbers - ;. e., used prior to the membrane filtration process. b) Large numbers of non-specific, non-coliforms may mask the appearance of coliform indicators on selective MF media. Generally coliform counts should be counted in the range of 20-80 per membrane filter with a total

bacteria 1 count NOT exceeding 200 co 11 oni es on the membrane surface.

c) Extensive comparison studies between the MPN and MF methodology show 1ed that the organism Aeromonas hydrophil a, a non-coliform, produces a sheen on the membrane filters. However, these colony sheens are more pin-pointed than those produced by true coliforms and can usually be eliminated in the

coliform counting procedure. The use of a fluorescent light 1>"!ill mini1mze the enumeration of this organism as a coliform. d) Industrial waste water may contain zinc, copper, or other heavy metallic compounds which can absorb onto the membrane filter and interfere subsequent bacterial development. However,the presence of these compounds in the MPN tubed media may also interfere with growth of coliforms and subsequent gas formation in the Durham fermentation vials. e) Indicator organisms stressed in the environment may be poorly recovered.

LABORATORY AND/OR FIELD APPARATUS AND MATERIALS

Culture dishes, 60 x 15 mm, 50 x 9 mm, plastic Filtration units, glass or stainless steel Portable MF Field Kit for field use; temperature set at 35 C 0.5 C Filter membranes individually wrapped, 9rid, 47 mm diameter, pore size 0.45 mm - 147 -

Absorbent Pads (for use with M-Endo Broth)

Forceps, fl at, smooth tipped Sterile pipettes, 10 ml and 1 ml/or stainless steel graduated cup Sterile sample bottles, polypropylene or glass Sterile dilution blanks, 99 and 90 ml (0.1% peptone water) Sterile 0.1% peptone water in larger bottles (for rinsing filters after f i lt ration) Vacuum pump, water guage (lab use) Portable butane, or alcohol burner Fluorescent lamp (portable for field use) Magnifying glass (field), Quebec Colony Counter (Laboratory) Water-proof, disposable plastic bag, for used Petri plates Pencil and pad for recording purposes Petri slides Prefi l ters Ethanol/Methanol with appropriate containers/atomizers for sterilizations. NOTE: Portable incubator with its components such as a stainless steel measuring cup, stainless steel filtration apparatus, syringe pump, stainless steel forceps with smooth tips to permit handling of filters without damage. This incubator may be connected to 115 volt AC, 230 volt AC, 6 volt DC, 12 volt DC, and 24 volt DC using the adaptors provided. Care should be taken to turn the selector switch to the proper indicated voltage. The temperature is set to 35°C ± 0.5°C. MEDIA AND REAGENTS *M-Endo Agar Les M-Endo Broth MF M-FC Broth Base M-Enterococcus Agar - 148 -

1% Rosalie Acid in 0.2 N Sodium hydroxide M-PYC Enrichment Broth 95% ethanol Methanol for sterilization purposes *NOTE: This is the medium of choice. This medium can be prepared in the laboratory and used in the field. Filtered membranes may be placed directly on the surface of the agar medium with or without the suggested pre-enrichment in lauryl tyyptose broth. The prepared medium should be stored in the dark at 4°C and used within seven days. Uninoculated controls should be used.

SUGGESTED SAMPLE QUANTITIES a) Finished waters: duplicate 10, 50, 100, and 200 ml volumes b) **Well waters, unpolluted lake waters: duplicates of 0.1, 1.0, 10.0, 50.0

and 100.0 ml aliquots depending on source. Field personnel should routinely attempt to filter volumes approaching 100 ml since counts are more accurately obtained when dilution factors are not too large ie., when

10 ml is filtered, the dilution factor is lQ_ in contrast to LO 1t1hen 100 ml is filtered, counts can be expressed accurately per 100

**NOTE: If aliquots smaller than 10.0 ml are to be used, place these aliauots in either 90 or 99 ml of sterile peptone water (0.1%), shake in e prescribed manner, and filter entire contents. c) Polluted water: depending on the extent of pollution as in (b) previous but also in reduced volumes. Dilutions may, at times, be required.

PROCEDURE (PORTABLE MF FIELD KIT) The stainless steel filter holder assembly is stored inside the field kit. This unit must be sterilized before use. First, the stainless steel receiver cup is removed from the funnel base assembly. Methanol is poured around tne - 149 -

base onto the asbestos wick and ignited. After 30 seconds, the cup is placed over the funnel and the assembly is left in the closed position for 15 minutes. This will sterilize the funnel due to the formation of formaldehyde resulting from the ignition and burning of methanol in the absence of oxygen. The cup can then be removed and placed under the filter base ready for filtration. Before use, the funnel should be rinsed with sterile distilled peptone water in order to wash out toxic residues. Sterilization between water and ice from the same location or different sources may be sterilized by flaming \'lith alcohol \'/hen a series of samples are run in one sequence.

The stainless steel forceps are used to transfer the sterile filters from their packaging material to the filter holder base and then to the plates. The forceps can be sterilized by dipping into methanol or ethanol and flaming.

The membrane filters are made of a cellulose acetate material having very small uniform sized pores which allow only particles smaller than bacterial cells to pass through. The filters trap all bacteria and larger particles on the upper gridded surface. When the pads are placed on the nutrient, the isolated bacterial cells on the surface of the membrane form a single mass of cells which is visible as a colony.

The filters are pre-sterilized (avoid the use of membranes sterilized by ethylene oxide since residues entrapped inside the filters are toxic to bacterial growth) and packaged in waxed paper. After being carefully removed and placed grid side up on the receptacle, the funnel assembly is replaced and the collar locked into position. - 150 -

The suction tube (attached to the syringe) is plugged into the appropriate hole in the filter holder base. Pumping the syringe produces the vacuum i ch draws the water through the membrane fi 11 ter. The apparatus ·is now set up for filtering a water sample.

In the actual filtration of a sample, 100 ml of water (see section on

"Suggested Sample Quantities" if smaller aliquots are used) is poured into the stainless steel measuring cup (graduated in 10, 25, 50, 100 and 200 has been sterilized by coating with alcohol and flaming. After measuring, the sample is then poured into the funnel. For 3 water samples from the same source, it is not necessary to sterilize the funnel between samples, ging filters is all that is necessary. The sample is drawn through the filter by pumping the syringe several strokes and then allowing the water to be drawn into the lower cup. A washdown of the funnel with sterile water should be used after each sample. Care should be taken in removing the filter after filtration as the vacuum remaining will cause it to be held against the supporting screen. The edge should be slowly lifted with the sterilized forceps.

In dealing with turbid water samples, filtering problems may occur as the suspended materi a 1 wi 11 clog the filter. 100 ml may not pass rough the filter and 50 ml or some smaller volume will have to be used as the sample.

Also Prefilters may be required (see section entitled "Limitations"). This should alays be noted in the reporting of results.

Heavily contaminated water sources have been found to give overcrowded

conditions on the filters making counting difficult. In thesE? instances a

number of dilutions will have to be made (see "Suggested Sample Quantities ),. - 151 -

After filtering the sample, the funnel is removed and the filter is placed into a Petri dish containing a prepared growth medium, i.e., M-Endo agar Les. When placing the filter onto the surface of the agar, care must be taken to prevent air bubble entrapment under the filter. This can be prevented by rolling the filter onto the surface while holding the Petri plate at an angle. The outer edges of the filter can be pressed down with the end of sterile forceps to help the filter make better contact with the agar. The plates are inverted, sealed with tape or placed in a small plastic bag and labelled, noting time and date of incubation prior to being placed on the rack in the incubator. Because the incubator is a dry air type, the lid of the incubating chamber should not be kept open any longer than necessary for loading the racks.

The colony counting phase of the field kit operation is the most critical.

The plates should be removed from the incubator at 24 ± 2 hours. Counting of colonies may be aided with a magnifying glass, Quebec Colony Counter, etc. Coliform colonies will be seen as dark pink to dark red plus a golden metallic sheen often with a greenish tint. The size of the colonies is variable. It is important to note that a fluorescent light source located as nearly directlj above the colonies as possible is best for distinguishing the colonies with the metallic sheen. The results of the counted colonies can be reported using the following: 100 x no. of colonies x dilution factor Col iforms per 100 ml = ...... _ __...... _ __v_o-=-1 u_m_e___,f,...,..i .,,...lt_e_r~e~d,..--,.m....,l~).-----~ where the dilution factor is the reciprocal of the dilutions used. For example if 1.0 ml (see 4.4) of a 1/10 dilution is filtered and 21 sheen - 152 -

colonies counted (should be done in duplicates) the no. coliforms /100 water is:

(lOO)(i:6(lO) = 21000 = 2.1 x 10 4

The filters themselves can be preserved as a permanent record placing them

into containers called "Petri slides" after drying. The use of the Petri

slides would be recommended in some cases where difficulties in field counting

arise and it is desirable to send the filters to the Headquarter's lab for

confirmation of counts.

Faecal coliforms: Use m-FC Broth. The membrane must be incubated in

tight-fitting plastic Petri di shes inverted and immersed in a water bath at

44.7°C ± 0.2°C for 24 hours. If petri dishes are not water-tight, they may be

placed in water-proof plastic bags before immersing. Faecal coliform colonies

are blue. Other coliforms produce grey to cream-coloured colonies. Counting

is done under magnification, as outlined in section on "colony counting phase

on page , and presents no difficulty. Count all blue colonies, regardless

of size or intensity of colour. Report results as "Faecal co"liforms/100

Enterococci: Prepare m-Enterococcus Agar, pour into the bottom half of 60 mm

plastic dishes and allow to solidify. Place filter pads in the upp1~r half

the same dishes and saturate each pad with 1.9 ml m-PYC Enrichment Broth.

Filter samp 1es and t ran sf er membranes to the saturated filter pads in tne

dishes. Incubate the closed dishes for 3 hours at 35°C. Transfer the

incubated membranes from the enrichment pads to the m-Enterococcus Agar in tne

lower half of the dishes. Incubate the dishes in an inverted position (agar - 153 - above) for the remainder of 48 hours at 35°C and then examine for faecal streptococci using lOx magnification. Count all red or pink colonies. Report

11 resu ts as: "Enterococci /100 ml •