Product Catalog

Total Page:16

File Type:pdf, Size:1020Kb

Product Catalog Product Catalog Drilling Fluids Testing Oil Well Cement Testing Industrial Products RheoVADR™ Rheometer see page 7 January 2016 Fann Instrument Company Fann Instrument Company designs and manufactures instruments for measuring the physical and chemical properties of fluids, especially the measurement of flow and viscosity. Fann offers a broad array of instruments that help improve efficiency while reducing costs for customers around the world. This catalog shows a product line that is a comprehensive set of instruments, accessories, test kits, and portable laboratories for testing drilling fluids, completion fluids, fracturing fluids, oilfield cements, and industrial slurries. Fann also provides reagents, supplies, and replacement parts through a worldwide distribution system. Based in Houston, Texas, Fann Instrument Company has been the leading supplier of quality instruments for oilfield analysis since 1939. More than 65 years of continuous production has meant continuous improvement. Fann instruments have proven to be accurate and rugged. Many instruments and test kits are designed to conform to the testing standards of the American Petroleum Institute (API), and are suitable for field and laboratory use. Others are designed to meet the requirements of the American Society for Testing and Materials (ASTM) as well as other technical specification groups. Our ongoing research and product development program represents an investment in leading edge technology and a commitment to the design of sophisticated instrumentation used for laboratory research and highly efficient portable kits used on remote rig sites and other field locations. As we make changes, there may be differences between the product versions shown in this catalog and the currently available item. Copyright © 2016 Fann Instrument Company All Rights Reserved. No part of this work covered by the copyright hereon may be reproduced or copied in any form or by any means -- graphic, electronic, or mechanical -- without first receiving the express written permission of Fann Instrument Company, Houston, Texas U.S.A. Fann reserves the right to make improvements in design, construction, and appearance of our products without prior notice. All prices, terms, descriptions and images are subject to change without prior notice. 2 Call Toll Free: 1.800.347.0450 Fann Around the World Fann AuthorizedFann Distributors Fann Authorized Distributors Fann Instrument Company products are available from companies around the world, Our distributors are as committed as we are to providing you with instruments that surpass your testing requirments and technical support that will keep you operating. There is an authorized distributor near you whether you are testing in the field or in a lab. Contact your distributor for supplies, new equipment, or routine maintenance. A list of distributors can be found on our web site www.fann.com. Fann World Service Technical Support Hotline For troubleshooting and technical assistance call our 24/7 Technical Support Hotline at 1-713-268-6350. You will be put in touch with a qualified service technician in your region who will help you determine how to meet your repair needs. Please note that this line is for troubleshooting and technical assistance only. Product Service and Support You may contact our service and support team during regular business hours (7 AM to 5 PM Central Time in the United States) at 1-281-871-4461 or 1-281-871-4484. Our fax number is 1-281-871-4446. Customer Service For customer service related issues and order support please call toll-free1-800-347-0450 or 1-281-871- 4482 from 7 AM to 5 PM Central Time US. Telephone: 1.281.871.4482 3 Contents Product Groups Products Calcimeters ........................................................... 34 Activity/Hygrometer Kits ...................................... 54 Cement Analyzers ................................................. 57 Aging Cells ............................................................ 22 Cement Curing ...................................................... 65 Aniline Point Determination Kit ........................... 56 Chemical Reagents ............................................... 81 Atmospheric Consistometer Model 165AT ......... 59 Filltration (HPHT) .................................................. 24 AutoCalcimeter Model 442 .................................. 34 Filtration (LPLT) ..................................................... 30 Automated Permeability Plugging Apparatus .... 32 Fluid Loss Tests ..................................................... 63 Basic Mud Test Kit ................................................. 45 Lab Equipment and Supplies ............................... 72 Bench Top Centrifuge ............................................ 73 Linear Swell Meter System .................................. 40 Blender Accessories ............................................. 70 Lubricity and Sticking ........................................... 36 Bobs ....................................................................... 12 Mixers and Blenders ............................................ 67 Calcimeters ........................................................... 35 Mud Testing Kits .................................................... 45 Capillary Suction Timer ........................................ 41 Oil and Water Testing ............................................ 52 Cement Cube Mold ............................................... 66 Permeability Plugging .......................................... 32 Cement Curing Autoclave .................................... 65 pH Meters .............................................................. 71 Centrifuge (Unheated) .......................................... 72 Products by Part Number ..................................... 85 Ceramic Filter Cores ............................................. 29 Roller Ovens .......................................................... 42 Ceramic Filter Discs .............................................. 33 Slurry Testing Kits ................................................. 50 CertifiedViscosity Standard Fluids ...................... 14 Test Cells ................................................................ 22 Chemical Reagents ............................................... 81 Testing Equipment ................................................ 37 Chiller for iX77® Rheometer ............................... 17 Testing Kits ............................................................ 43 Chloride, Alkalinity & Water Hardness ................ 43 Viscometers and Rheometers ............................... 6 Chloride Content Kit ............................................. 44 Circular Expansion Curing Kit .............................. 66 Cold Water Rheology Kit ...................................... 13 Compactor ............................................................. 41 Compressive Strength Tester ............................... 66 Constant Speed Mixer .......................................... 67 Corrosion Test Cell ................................................ 23 Data Manager Software ....................................... 60 Differential Sticking Tester .................................... 36 Digital Pocket Balance ......................................... 76 Digital Pocket Balance .......................................... 76 Digital Top Loading Balance ................................. 76 Dispersator / High Shear Mixer ........................... 68 DNA System (Software & Data Network Adapter) 8 Drill Pipe Corrosion Coupons .............................. 23 DW-3 Calibration Check Kit .................................. 13 Electrical Stability Tester ....................................... 38 EP (Extreme Pressure) Lubricity Tester................ 36 Fann Authorized Distributors ................................. 3 Fann World Service ................................................. 3 Field Portable Mixer .............................................. 68 Filter Press Cell Clamp ......................................... 26 Filtrate Analysis Kit ............................................... 43 Five-Spindle Multi-Mixer® ................................... 69 Fluid Calibration Check Kit ................................... 14 Fluoroscope ........................................................... 76 Garrett Gas Train Kit .............................................. 55 Half Area Filter Press ............................................ 31 Fann AuthorizedFann Distributors 4 Call Toll Free: 1.800.347.0450 Contents Fann AuthorizedFann Distributors Hamilton Beach Mixers ........................................ 69 Roller Ovens with Timer ....................................... 21 High Temperature Aging Cells ............................. 22 Rotors .................................................................... 13 HPHT Consistometer Model 290 ......................... 58 Seven Speed Blender ........................................... 70 HPHT Filter Press (175 ml) ................................... 26 Seven Speed HB Mixer ........................................ 69 HPHT Filter Press (500 ml) ................................... 27 Shearometer ......................................................... 38 HPHT Safe Cell ...................................................... 25 Sieve Shaker ......................................................... 73 HT4700 HPHT Filter Press .................................... 24 Single Speed Blenders ........................................
Recommended publications
  • A Fiber Optic Ammonia Sensor Using a Universal Ph Indicator
    Sensors 2014, 14, 4060-4073; doi:10.3390/s140304060 OPEN ACCESS sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Article A Fiber Optic Ammonia Sensor Using a Universal pH Indicator Adolfo J. Rodríguez 1,*, Carlos R. Zamarreño 2, Ignacio R. Matías 2, Francisco. J. Arregui 2, Rene F. Domínguez Cruz 1 and Daniel. A. May-Arrioja 1 1 Fiber and Integrated Optics Laboratory, Electronics Engineering Department, UAM Reynosa Rodhe, Universidad Autónoma de Tamaulipas, Carr. Reynosa-San Fernando S/N, Reynosa, Tamaulipas 88779, Mexico; E-Mails: [email protected] (R.F.D.C.); [email protected] (D.A.M.-A.) 2 Departamento de Ingeniería Eléctrica y Electrónica, Universidad Pública de Navarra, Edif. Los Tejos, Campus Arrosadia, Pamplona España 31006, Spain; E-Mails: [email protected] (C.R.Z.); [email protected] (I.R.M.); [email protected] (F.J.A.) * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +52-899-9213300 (ext. 8315); Fax: +52-899-921-3300 (ext. 8050). Received: 27 December 2013; in revised form: 12 February 2014 / Accepted: 18 February 2014 / Published: 27 February 2014 Abstract: A universal pH indicator is used to fabricate a fiber optic ammonia sensor. The advantage of this pH indicator is that it exhibits sensitivity to ammonia over a broad wavelength range. This provides a differential response, with a valley around 500 nm and a peak around 650 nm, which allows us to perform ratiometric measurements. The ratiometric measurements provide not only an enhanced signal, but can also eliminate any external disturbance due to humidity or temperature fluctuations.
    [Show full text]
  • BROOKFIELD DIAL READING VISCOMETER with Electronic Drive
    BROOKFIELD DIAL READING VISCOMETER with Electronic Drive Operating Instructions Manual No. M00-151-I0614 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY with offices in : Boston • Chicago • London • Stuttgart • Guangzhou BROOKFIELD ENGINEERING LABORATORIES, INC. 11 Commerce Boulevard, Middleboro, MA 02346 USA TEL 508-946-6200 or 800-628-8139 (USA excluding MA) FAX 508-946-6262 INTERNET http://www.brookfieldengineering.com TABLE OF CONTENTS I. INTRODUCTION .....................................................................................5 I.1 Components .......................................................................................................5 I.2 Utilities ................................................................................................................6 I.3 Specifications .....................................................................................................6 I.4 Set-Up ................................................................................................................7 I.5 IQ, OQ, PQ .........................................................................................................7 I.6 Safety Symbols and Precautions .......................................................................8 I.7 Cleaning .............................................................................................................8 II. GETTING STARTED ..............................................................................9 II.1 Operation ...........................................................................................................9
    [Show full text]
  • Science Safety
    2010 Mississippi Science Framework Science Safety The guides that are cited below were developed by the Council of State Science Supervisors (CSSS) with support from the Eisenhower National Clearinghouse for Mathematics and Science Education, the National Aeronautics and Space Administration, Dupont Corporation, Intel Corporation, Americal Chemical Society, and the National Institutes of Health. Science Safety Booklets may be printed for use by educators. • Science Safety Booklets • Science and Safety: It's Elementary (PDF) - A Elementary Safety Guide • Science and Safety, Making the Connection (PDF) - A Secondary Safety Guide . Approved July 25, 2008 1 2010 Mississippi Science Framework A SUGGESTED PATTERN FOR CHEMICAL STORAGE The alphabetical method for storing chemicals presents hazards because chemicals, which can react violently with each other, may be stored in close proximity. Schools may wish to devise a simple color-coding scheme to address this problem. The code shown below, reproduced with permission from School Science Laboratories-A Guide to Some Hazardous Substances by the Council of State Science Supervisors, includes both solid and striped colors which are used to designate specific hazards as follows: Red - Flammability hazard: Store in a flammable chemical storage area. Red Stripe - Flammability hazard: Do not store in the same area as other flammable substances. Yellow - Reactivity hazard: Store separately from other chemicals. Yellow Stripe - Reactivity hazard: Do not store with other yellow coded chemicals; store separately. White - Contact hazard: Store separately in a corrosion-proof container. White Stripe - Contact hazard: Not compatible with chemicals in solid white category. Blue - Health hazard: Store in a secure poison area. Orange - Not suitably characterized by any of the foregoing categories.
    [Show full text]
  • HAAKE Viscometer Standard Operating Procedure [Updated Sept 10, 2014]
    HAAKE Viscometer Standard Operating Procedure [Updated Sept 10, 2014] HAAKE Viscometer 7 R+ Location of Machine: Composites Lab, RFM 1218 Location of SOP and Machine Operating & Safety Manual: Composites Lab website under resources; Composites Lab TRACS site; and Hardcopy near machine. Emergency Contact: Call 911 Call EHS & Risk Management at 512-245-3616 Call Head Lab Technician, Dr. Ray Cook (office 512-245-2050) Call Dr. Jitendra S Tate (office 512-245-4872) Before using this machine: You must have permission from Dr. Tate. You must have received formal training from technician or, trained research student (designated by Dr. Tate) related to machine safety and operation. You must read and understand SOP and Machine Cleaning Manual. You must use this machine under direct supervision of Dr. Tate or, Dr. Cook or, trained research student (designated by Dr. Tate). You must have signed “Lab Rules” document with Dr. Tate. This document must be signed every semester fall, spring, and summer (as applicable). If you do NOT follow above instructions you will be held responsible for your own safety and damages. Safety Precautions: Protective Equipment: Prior to performing this procedure, the following personal protective equipment must be obtained and ready for use: Gloves, Safety Goggles, Face Mask, Lab Coat. Important Safeguards: 1. Prior to performing this procedure, the following safety equipment must be accessible and ready for use: (e.g. chemical fume hood, biological safety cabinet, laminar flow hood, chemical spill kits) Fume hood 2. All liquids should be drained to containers for chemical disposal and properly marked. 3. In the event that a hazardous material spill during this procedure, be prepared to clean with cleaner according to MSDS of materials used.
    [Show full text]
  • Building and Validating a Rotational Viscometer Brian Cherrington & Jack Rothstein Mechanical Engineering Faculty Mentors: Dr
    Building and Validating a Rotational Viscometer Brian Cherrington & Jack Rothstein Mechanical Engineering Faculty Mentors: Dr. Maria-Isabel Carnasciali, Dr. Samuel Daniels Abstract This project was an effort to redesign an initial prototype rotational viscometer to experimentally test whether or not viscosity values vary significantly when the geometry of the viscometer is changed. The scope of the project involved designing and building a viscometer that could vary the gap between the inner and outer cylinders, variation of the testing fluid’s temperature, and control of the device’s RPM. After weeks of planning, designing, and fabrication the new viscometer was complete. In order to control the device, monitor the sensor readings, and calculate the testing fluid’s viscosity a LabVIEW program was created. Testing on medium to high viscous fluids was completed to determine if the viscosity values and the geometry of the viscometer are dependent or independent of each other. The results did show a correlation between measured viscosity and variations in the geometry of the viscometer. More testing is required to further verify the results and properly calibrate the device. Introduction For this project a new design was conceptualized, fabricated, and tested. This new design met several criteria including, Viscosity is often referred to as a fluid’s thickness or how much it resists deformation due to an applied force. Designed for future use in ME labs; Rotational viscometers measure the amount of torque needed Designed to be durable, sustainable, and easy to to rotate an object moving through fluid at a known RPM. dissemble and clean; Using the measured torque, RPM, and dimensions of the Multiple inner cylinders for varying gap sizes; device, the viscosity can be calculated using equation 1.
    [Show full text]
  • Detergent Residue Testing Using a Ph Meter, Ph Indicator, Or Test Kit
    Alconox, Inc. The Leader in Critical Cleaning 30 Glenn St. White Plains NY 10603 USA Tel 914.948.4040 Fax 914-948-4088 www.alconox.com [email protected] Detergent Residue Testing Using a pH Meter, pH indicator, or Test Kit The following test procedures are suitable for detecting detergent residues resulting from improper rinsing and can be used to meet laboratory accreditation guidelines and questionnaires such as the College of American Pathologist program of State water lab accreditation programs. A. pH Meter Method 1. Rinse a small clean beaker by filling and emptying 3 times with source water. 2. Fill a 4th time and measure pH using a pH meter. Record the pH as source water pH. 3. Using a piece of cleaned glassware you wish to test, fill about 10% full with source water (10ml into 100ml beaker). Use more water if necessary to get enough water to be able to sufficiently immerse the pH meter electrode in your measuring beaker. 4. Swish water in glassware to extract residues from all possible surfaces. 5. Take pH reading with pH meter and record as glassware pH. 6. Any significant increase in pH indicates possible alkaline detergent residue. A significant change is 0.2 or more pH units on a pH meter measuring to 0.1 pH units of sensitivity. A result of less than 0.2-pH units change indicates properly rinsed glassware. Note: If deionized water is used as the sample water, a slight amount (10-20 mg/L) of reagent grade, non-buffering salt (NaCl, CaCl2) should be added to the sample water to allow pH meter to function properly.
    [Show full text]
  • Miniav®-X Automatic Viscometer Instruction & Operation Manual
    MiniAV®-X Automatic Viscometer Instruction & Operation Manual 81.2254 i CONTENTS 1 INTRODUCTION/INSTALLATION 1 The miniAV®-X Automatic Viscometer .................................................................................. 1 Measuring kinematic viscosity ............................................................................................... 2 Safety cautions ..................................................................................................................... 2 Specifications ....................................................................................................................... 4 Installation ............................................................................................................................ 4 Required installation components ............................................................................... 4 Vacuum Pump unit connections ................................................................................. 6 Bath unit connections ................................................................................................ 6 VISCPRO® for Windows® XP® ............................................................................................ 6 Installing VISCPRO® software .............................................................................................. 7 Computer requirements ............................................................................................. 7 Windows® XP® installation .......................................................................................
    [Show full text]
  • Method 3650B: Acid-Base Partition Cleanup, Part of Test Methods For
    METHOD 3650B ACID-BASE PARTITION CLEANUP 1.0 SCOPE AND APPLICATION 1.1 Method 3650 is a liquid-liquid partitioning cleanup method to separate acid analytes, e.g., organic acids and phenols, from base/neutral analytes, e.g. amines, aromatic hydrocarbons, and halogenated organic compounds, using pH adjustment. It may be used for cleanup of petroleum waste prior to analysis or further cleanup (e.g., alumina cleanup). The following compounds can be separated by this method: _______________________________________________________________________________ Compound Name CAS No.a Fraction Benz(a)anthracene 56-55-3 Base-neutral Benzo(a)pyrene 50-32-8 Base-neutral Benzo(b)fluoranthene 205-99-2 Base-neutral Chlordane 57-74-9 Base-neutral Chlorinated dibenzodioxins Base-neutral 2-Chlorophenol 95-57-8 Acid Chrysene 218-01-9 Base-neutral Creosote 8001-58-9 Base-neutral and Acid Cresol(s) Acid Dichlorobenzene(s) Base-neutral Dichlorophenoxyacetic acid 94-75-7 Acid 2,4-Dimethylphenol 105-67-9 Acid Dinitrobenzene 25154-54-5 Base-neutral 4,6-Dinitro-o-cresol 534-52-1 Acid 2,4-Dinitrotoluene 121-14-2 Base-neutral Heptachlor 76-44-8 Base-neutral Hexachlorobenzene 118-74-1 Base-neutral Hexachlorobutadiene 87-68-3 Base-neutral Hexachloroethane 67-72-1 Base-neutral Hexachlorocyclopentadiene 77-47-4 Base-neutral Naphthalene 91-20-3 Base-neutral Nitrobenzene 98-95-3 Base-neutral 4-Nitrophenol 100-02-7 Acid Pentachlorophenol 87-86-5 Acid Phenol 108-95-2 Acid Phorate 298-02-2 Base-neutral 2-Picoline 109-06-8 Base-neutral Pyridine 110-86-1 Base-neutral Tetrachlorobenzene(s) Base-neutral Tetrachlorophenol(s) Acid Toxaphene 8001-35-2 Base-neutral Trichlorophenol(s) Acid 2,4,5-TP (Silvex) 93-72-1 Acid _______________________________________________________________________________ a Chemical Abstract Service Registry Number.
    [Show full text]
  • Acids and Bases Experiments (Organic Classes)
    Acids and Bases Experiments (Organic Classes) NaHCO3 (sodium bicarbonate, baking soda) and vinegar (dilute acetic acid) will be used to shoot a cork out of a bottle to show that some acid-base reactions generate gases like CO2. All students in the class will participate in a voice-activated chemical reaction. Students will remove a stopper and speak into a flask containing base and an indicator that will change color once enough CO2 is introduced from the students’ breath. Further color changes from basic to acidic conditions are illustrated using natural and household liquids and a universal indicator prepared from red cabbage juice. Finally, conversion between colorless and colored forms of different acid-base indicators in unusual settings will be shown in the “invisible painting” experiment. Supplies Needed: For the rocket reaction: You provide the following items indicated in red and starred: * empty 1 L plastic soda bottle with label removed * vinegar (colorless) Plastic powder funnel (we provide) cork with streamers attached by a thumbtack (we provide) container of de-ionized water (we provide, you refill as needed) sodium bicarbonate (we provide, return unused) Please clean and return all materials For the voice-activated chemical reaction: water that we provide as 250 mL Erlenmeyer flask (we provide)) soon as possible. dropper bottle with colorless phenolphtalein indicator (we provide) Other students may small amount of 1 M NaOH solution (we provide) need to use this “kit” disposable plastic droppers (we provide) for their ChemDemo!! For the universal pH indicator from red cabbage: * Red cabbage juice (you make the day before the demo) * 1 lemon, 1 soap bar, Sprite, vinegar, drain cleaner * 7 stirring rods (e.g.
    [Show full text]
  • List of Equipments in the Department (Chemical Engineering) Mechanical
    List of Equipments in the Department (Chemical Engineering) Mechanical Operation lab Fluid Mechanics Lab Heat transfer Lab Mass Transfer lab • Cyclone Separator • Reynold’s Apparatus • Double Pipe Heat Exchanger • Tray Dryer • Plate & Frame Filter Press • Bernoulli’s Theorem Apparatus • Shell & Tube Heat Exchanger • Sieve Plate Distillation Column • Vibrating Screen • Pitot Tube Apparatus • Vertical Condenser • Liquid-Liquid Extraction • Jaw Crusher • Calibration of Orifice meter, • Computerized Control Shell & • Adsorption of CO 2 • Ball Mill Venturi meter and Rota meter Tube Heat Exchanger • Steam Distillation • Roll Crusher • Coefficient of Discharge of • Thermal Conductivity of Metal • Bubble Cap Distillation Column • Rotary Vacuum filter Orifice and Mouthpiece Bar • Cooling Tower • Fluidized Bed • Film & Drop Wise Condensation • Diffusivity Apparatus • Single Effect Evaporator • Fluidized Bed Dryer • Simple Steam Distillation • Simple Distillation • VLE Apparatus • Equilibrium Flash Distillation • Humidification & Dehumidification • Refractometer Process Control Lab Chemical Reaction Engg. Lab Fuel Combustion Energy Technology Lab Environmental Lab • Process Training Simulator with • Plug Flow Reactor • Flash & Fire Point Apparatus • BOD Incubator Modules (Software) • Isothermal Batch Reactor • Aniline Point Apparatus • pH Meter • Pressure Control System • Single Tube Packed Bed Reactor • Orsat Gas Analysis Apparatus • Sedimentation Apparatus • Flow Control System • RTD in CSTR / Mixed flow • Redwood Viscometer • UV-VIS Spectrophotometer • pH control System Reactor • Bomb Calorimeter • DO Meter • Real Time Simulator Trainer • RTD in Tubular Reactor • Smoke Point Apparatus • Digital Conductivity Meter • Level Control System • Adiabatic Batch Reactor • Temperature Control System • Distillation Column • Two Tank Interacting system • Two Tank Non-Interacting System • CSTR Control System Research Equipments • UV-Spectrophotometer • Gas Chomatography .
    [Show full text]
  • Construction of a Capillary Viscometer and the Study of Non-Newtonian Liquids" (1965)
    Scholars' Mine Masters Theses Student Theses and Dissertations 1965 Construction of a capillary viscometer and the study of non- Newtonian liquids Hsun Kuang Yang Follow this and additional works at: https://scholarsmine.mst.edu/masters_theses Part of the Chemical Engineering Commons Department: Recommended Citation Yang, Hsun Kuang, "Construction of a capillary viscometer and the study of non-Newtonian liquids" (1965). Masters Theses. 7238. https://scholarsmine.mst.edu/masters_theses/7238 This thesis is brought to you by Scholars' Mine, a service of the Missouri S&T Library and Learning Resources. This work is protected by U. S. Copyright Law. Unauthorized use including reproduction for redistribution requires the permission of the copyright holder. For more information, please contact [email protected]. ... ··f • CONSTRUCTION OF A CAPILLARY VISCOMETER -'"' '. ·~ i : AND THE STUDY OF NON-NEWTONIAN LIQUIDS BY HSUN KUANG YANG I fl ;/() 1\?: f A THESIS submitted to the faculty of the UNIVERSITY OF MISSOURI AT ROLLA in partial fulfillment of the requirements for the Degree of MASTER OF SCIENCE IN CHEMICAL ENGINEERING Rolla, Missouri 1965 Approved by (advisor) ii ABSTRACT A capillary tube viscometer was built for the purpose of investigating the fluid properties of non-Newtonian aqueous CMC and Carbopol solutions. The viscometer was tested with Newtonian liquids (glycerine, water and two different oils) having known viscosities to insure that the viscometer was operating correctly. The shear stress-shear rate data obtained for different concen­ trations of CMC and Carbopol solutions were correlated using the simple power law model. The power law constants were only slightly affected by saturating the solution with iodine and carbon tetrachloride.
    [Show full text]
  • Process Skills Review Warm-Up C
    Process Skills Review Warm-Up C. • Define function • Match the following 1. Puts out fire 2. Curved line of liquid in a graduated cylinder 3. Used to observe insects A. B. Which of the following describes the correct way to handle chemicals in a laboratory? A. It is safe to combine unknown chemicals as long as only small amounts are used. B. Return all chemicals to their original containers. C. Always pour extra amounts of the chemicals called for the experiment. D. To test for odors, always use a wafting motion. Which of the following describes the correct way to handle chemicals in a laboratory? A. It is safe to combine unknown chemicals as long as only small amounts are used. B. Return all chemicals to their original containers. C. Always pour extra amounts of the chemicals called for the experiment. D. To test for odors, always use a wafting motion. What task is being performed in the picture? A. measuring mass with a graduated cylinder B. measuring length with a triple beam balance C. measuring mass with a triple beam balance D. measuring length with a metric ruler What task is being performed in the picture? A. measuring mass with a graduated cylinder B. measuring length with a triple beam balance C. measuring mass with a triple beam balance D. measuring length with a metric ruler John and Lisa are conducting an experiment in their 7th grade science class in which they are handling potentially dangerous chemicals. As John is pouring a chemical from a beaker to a graduated cylinder, he splashes some of the chemical into his eyes.
    [Show full text]