A Two-Dimensional Quadrupole Ion Trap Mass Spectrometer

Total Page:16

File Type:pdf, Size:1020Kb

A Two-Dimensional Quadrupole Ion Trap Mass Spectrometer CORE Metadata, citation and similar papers at core.ac.uk Provided by Elsevier - Publisher Connector FOCUS:QUADRUPOLE ION TRAPS A Two-Dimensional Quadrupole Ion Trap Mass Spectrometer Jae C. Schwartz and Michael W. Senko LC and LC/MS Division, Thermo Finnigan, San Jose, CA, USA John E. P. Syka LC and LC/MS Division, Thermo Finnigan, Charlottesville, VA, USA The use of a linear or two-dimensional (2-D) quadrupole ion trap as a high performance mass spectrometer is demonstrated. Mass analysis is performed by ejecting ions out a slot in one of the rods using the mass selective instability mode of operation. Resonance ejection and excitation are utilized to enhance mass analysis and to allow isolation and activation of ions for MSn capability. Improved trapping efficiency and increased ion capacity are observed relative to a three-dimensional (3-D) ion trap with similar mass range. Mass resolution comparable to 3-D traps is readily achieved, including high resolution at slower scan rates, although adequate mechanical tolerance of the trap structure is a requirement. Additional advantages of 2-D over 3-D ion traps are also discussed and demonstrated. (J Am Soc Mass Spectrom 2002, 13, 659–669) © 2002 American Society for Mass Spectrometry wo dimensional (2-D) radio frequency multipole Despite the previously described advantages and the ion traps have been used for several years for the recent progress with 2-D ion traps in hybrid instru- Tstudy of spectroscopic and other physical prop- ments, only a few examples have appeared using these erties of ions [1,2]. The earliest application of 2-D traps as stand-alone mass spectrometers. Senko et al. multipole ion traps in mass spectrometry involved the recently demonstrated image current detection with FT use of the collision cell of a triple quadrupole instru- analysis in a 2-D ion trap which utilized independent ment for studying ion-molecule reactions [3]. More detection electrodes between the quadrupole rods [17]. recently, multipole ion traps have been used in mass Although promising results were presented, space spectrometers as part of hybrid systems including Fou- charge effects were found to limit this configuration’s rier transform ion cyclotron resonance (FTICR) [4–7], ultimate performance as the motion of the ions is time-of-flight (TOF) [8–11], and standard three-dimen- largely restricted to one of the symmetry planes of the sional (3-D) ion trap mass spectrometers [12,13]. Several device. The relative insensitivity of the image current of the quadrupole based 2-D ion traps are capable of ion detection scheme precluded the use of lower num- mass selective isolation and activation of ions including bers of trapped ions to avoid such space charge effects. MS3 analysis [7,9–11]. Welling et al. demonstrated two variations of mass Syka and Fies have described the theoretical advan- selective instability in a stand-alone 2-D quadrupole ion tages of 2-D versus 3-D quadrupole ion traps for Fourier trap [18]. The first method, referred to as “q-scanning”, transform mass spectrometry [14]. These advantages exploited the field penetration of the detector between include reduced space charge effects due to the in- the quadrupole rods to allow for ion extraction using a creased ion storage volume, and enhanced sensitivity downward ramp of the RF voltage. This allowed rela- for externally injected ions due to higher trapping tively quick scanning of a broad mass range (1 second efficiencies. Bier and Syka described several forms of scan from 20–1000 m/z), but produced mass spectral linear and circular 2-D ion traps with larger ion capacity resolution of only five to six. The second method, to be used as mass spectrometers [15] using the mass referred to as “secular scanning”, used frequency swept selective instability mode of operation [16] similar to parametric excitation to eject ions between the quadru- that used in all commercial 3-D quadrupole ion trap pole rods. Although the scan rate was 100x slower than instruments. the q-scan, a resolution of 800 at m/z 130 was obtained. Lammert et al. have presented preliminary results using a toroidal ion trap with mass selective instability Published online April 26, 2002 [19]. Although this trap did not use the linear geometry Address reprint requests to Jae C. Schwartz, Thermo Finnigan, 355 River Oaks Parkway, San Jose, CA 95134, USA. E-mail: jschwartz@ of traditional 2-D ion traps, the quadrupolar trapping thermofinnigan.com potential was two dimensional in nature, and did © 2002 American Society for Mass Spectrometry. Published by Elsevier Science Inc. Received February 8, 2002 1044-0305/02/$20.00 Revised March 11, 2002 PII S1044-0305(02)00384-7 Accepted March 11, 2002 660 SCHWARTZ ET AL. J Am Soc Mass Spectrom 2002, 13, 659–669 Figure 1. Basic design of the two-dimensional linear ion trap. provide the benefit of increased ion storage capacity. Recently, Hager has demonstrated a novel ion trapping mode of operation on a modified triple quadruopole [20]. Fringe field effects caused by lenses at the ends of the quadrupole, normally considered detrimental, are exploited to eject trapped ions axially in a mass depen- dent fashion. Figure 2. Simion simulation of the resonance excitation field Here we apply many of the ideas for mass spectral comparing (a) a three section device and (b) a single section device analysis with 2-D quadrupole ion traps previously with end plates for axial trapping. described by this laboratory [14,15]. The 2-D ion trap described here is capable of operating in a manner lenses. As shown, the radial dipole field has a signifi- analogous to a conventional 3-D ion trap, but also cant axial component in the region near the end lenses. demonstrates distinct and unique operational character- In this region, ions will experience some axial excita- istics. Experimental data is provided to support the tion, which could lead to unintended axial ejection. This predicted advantages of an increased ion storage capac- approach to avoiding fringe field effects is similar to ity and enhanced trapping efficiency of externally in- that utilized in FTICR cell design for reducing undesir- jected ions. General performance and capabilities of the able axial ejection [21]. A similar distortion also occurs instrumental configuration are demonstrated along to the quadrupolar trapping potential at the end of the with other unique advantages of this type of mass single section device. This distortion has recently been spectrometer. exploited to generate spectra through mass selective axial ejection [20]. Experimental A 0.25mm high slot was cut along the middle 30 mm of the center section of one rod for ion ejection. To help The basic design of the 2-D ion trap used in this work is compensate for the detrimental field effects due to the depicted in Figure 1. The quadrupole structure has presence of the slot, the rod with the slot and the rod hyperbolic rod profiles with an r0 of 4 mm, similar to opposite it (the X rods) were moved out from the center that used in the Finnigan TSQ 700 series triple quadru- 0.75 mm beyond their normal position. This appears to pole instrument, but each rod is cut into three axial have analogous effects to the “stretch” in most commer- sections of 12, 37, and 12 mm length. The three sections, cial 3D ion traps [22] and is the subject of ongoing each with a discreet DC level, allow containment of the investigation and optimization. The length of the center ions along the axis in the central section of the device, section was limited so that the exiting beam of ions avoiding any possible fringe field distortions to the would be collected by the standard detection system of trapping and resonance excitation fields. a commercial Thermo Finnigan LCQ 3-D (San Jose, The ability to avoid fringe field distortions for the California) ion trap. This detector system includes a dipole resonance excitation field is shown in Figure 2a. conversion dynode held at Ϫ15 kV (for positive ions) All three sections of the top rod have 1V applied, and all and a channeltron electron multiplier. In order to assure three sections of the bottom rod have Ϫ1V applied. that ions are efficiently focused onto the detector, the Application of appropriate potentials to the end sec- ion optics simulation program Simion was used to tions restricts ions to the center section of the trap, examine the trajectories of ions exiting the 2-D ion trap. where the dipole field has no axial component. For the Examples are shown in Figure 3 where 100 eV and 10 single section trap shown in Figure 2b, the axial trap- keV ions [23], distributed along the entire length of the ping potential has to be created by voltages on the end slot, are all focussed onto the Ϫ15kV dynode cup. J Am Soc Mass Spectrom 2002, 13, 659–669 TWO-DIMENSIONAL QUADRUPOLE ION TRAP 661 ions. For the RF and AC signals applied to each rod, the voltages need to be applied equally across all segments of the rod to minimize any unintended axial fields. The appropriate combination of the above potentials results in nine separate voltages applied to the twelve elec- trodes. In initial experiments, the RF electronic system of an LCQ was adapted to apply the main RF voltage to only the Y quadrupole rods. A tri-filar (three-wire) RF transformer coil was constructed which allowed the coupling of three DC voltages for the three axial sec- Figure 3.(a) Simion simulation of 100 eV ions exiting the 2-D tions of the Y rod set with the main quadrupolar RF.
Recommended publications
  • Mass Spectrometry: Quadrupole Mass Filter
    Advanced Lab, Jan. 2008 Mass Spectrometry: Quadrupole Mass Filter The mass spectrometer is essentially an instrument which can be used to measure the mass, or more correctly the mass/charge ratio, of ionized atoms or other electrically charged particles. Mass spectrometers are now used in physics, geology, chemistry, biology and medicine to determine compositions, to measure isotopic ratios, for detecting leaks in vacuum systems, and in homeland security. Mass Spectrometer Designs The first mass spectrographs were invented almost 100 years ago, by A.J. Dempster, F.W. Aston and others, and have therefore been in continuous development over a very long period. However the principle of using electric and magnetic fields to accelerate and establish the trajectories of ions inside the spectrometer according to their mass/charge ratio is common to all the different designs. The following description of Dempster’s original mass spectrograph is a simple illustration of these physical principles: The magnetic sector spectrograph PUMP F DD S S3 1 r S2 Fig. 1: Dempster’s Mass Spectrograph (1918). Atoms/molecules are first ionized by electrons emitted from the hot filament (F) and then accelerated towards the entrance slit (S1). The ions then follow a semicircular trajectory established by the Lorentz force in a uniform magnetic field. The radius of the trajectory, r, is defined by three slits (S1, S2, and S3). Ions with this selected trajectory are then detected by the detector D. How the magnetic sector mass spectrograph works: Equating the Lorentz force with the centripetal force gives: qvB = mv2/r (1) where q is the charge on the ion (usually +e), B the magnetic field, m is the mass of the ion and r the radius of the ion trajectory.
    [Show full text]
  • Orbitrap Fusion Tribrid Mass Spectrometer
    MASS SPECTROMETRY Product Specifications Thermo Scientific Orbitrap Fusion Tribrid Mass Spectrometer Unmatched analytical performance, revolutionary MS architecture The Thermo Scientific™ Orbitrap Fusion™ mass spectrometer combines the best of quadrupole, Orbitrap, and linear ion trap mass analysis in a revolutionary Thermo Scientific™ Tribrid™ architecture that delivers unprecedented depth of analysis. It enables life scientists working with even the most challenging samples—samples of low abundance, high complexity, or difficult-to-analyze chemical structure—to identify more compounds faster, quantify them more accurately, and elucidate molecular composition more thoroughly. • Tribrid architecture combines quadrupole, followed by ETD or EThCD for glycopeptide linear ion trap, and Orbitrap mass analyzers characterization or HCD followed by CID • Multiple fragmentation techniques—CID, for small-molecule structural analysis. HCD, and optional ETD and EThCD—are available at any stage of MSn, with The ultrahigh resolution of the Orbitrap mass subsequent mass analysis in either the ion analyzer increases certainty of analytical trap or Orbitrap mass analyzer results, enabling molecular-weight • Parallelization of MS and MSn acquisition determination for intact proteins and confident to maximize the amount of high-quality resolution of isobaric species. The unsurpassed data acquired scan rate and resolution of the system are • Next-generation ion sources and ion especially useful when dealing with complex optics increase system ease of operation and robustness and low-abundance samples in proteomics, • Innovative instrument control software metabolomics, glycomics, lipidomics, and makes setup easier, methods more similar applications. powerful, and operation more intuitive The intuitive user interface of the tune editor The Orbitrap Fusion Tribrid MS can perform and method editor makes instrument calibration a wide variety of analyses, from in-depth and method development easier.
    [Show full text]
  • Electrification Ionization: Fundamentals and Applications
    Louisiana State University LSU Digital Commons LSU Doctoral Dissertations Graduate School 11-12-2019 Electrification Ionization: undamentalsF and Applications Bijay Kumar Banstola Louisiana State University and Agricultural and Mechanical College Follow this and additional works at: https://digitalcommons.lsu.edu/gradschool_dissertations Part of the Analytical Chemistry Commons Recommended Citation Banstola, Bijay Kumar, "Electrification Ionization: undamentalsF and Applications" (2019). LSU Doctoral Dissertations. 5103. https://digitalcommons.lsu.edu/gradschool_dissertations/5103 This Dissertation is brought to you for free and open access by the Graduate School at LSU Digital Commons. It has been accepted for inclusion in LSU Doctoral Dissertations by an authorized graduate school editor of LSU Digital Commons. For more information, please [email protected]. ELECTRIFICATION IONIZATION: FUNDAMENTALS AND APPLICATIONS A Dissertation Submitted to the Graduate Faculty of the Louisiana State University and Agricultural and Mechanical College in partial fulfillment of the requirements for the degree of Doctor of Philosophy in The Department of Chemistry by Bijay Kumar Banstola B. Sc., Northwestern State University of Louisiana, 2011 December 2019 This dissertation is dedicated to my parents: Tikaram and Shova Banstola my wife: Laxmi Kandel ii ACKNOWLEDGEMENTS I thank my advisor Professor Kermit K. Murray, for his continuous support and guidance throughout my Ph.D. program. Without his unwavering guidance and continuous help and encouragement, I could not have completed this program. I am also thankful to my committee members, Professor Isiah M. Warner, Professor Kenneth Lopata, and Professor Shengli Chen. I thank Dr. Fabrizio Donnarumma for his assistance and valuable insights to overcome the hurdles throughout my program. I appreciate Miss Connie David and Dr.
    [Show full text]
  • A Researcher's Guide to Mass Spectrometry‐Based Proteomics
    Proteomics 2016, 16, 2435–2443 DOI 10.1002/pmic.201600113 2435 TUTORIAL A researcher’s guide to mass spectrometry-based proteomics John P. Savaryn1,2∗, Timothy K. Toby3∗ and Neil L. Kelleher1,3,4 1 Proteomics Center of Excellence, Northwestern University, Evanston, Illinois, USA 2 Comprehensive Transplant Center, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA 3 Department of Molecular Biosciences, Northwestern University, Evanston, Illinois, USA 4 Department of Chemistry, Northwestern University, Evanston, Illinois, USA Mass spectrometry (MS) is widely recognized as a powerful analytical tool for molecular re- Received: February 24, 2016 search. MS is used by researchers around the globe to identify, quantify, and characterize Revised: May 18, 2016 biomolecules like proteins from any number of biological conditions or sample types. As Accepted: July 8, 2016 instrumentation has advanced, and with the coupling of liquid chromatography (LC) for high- throughput LC-MS/MS, a proteomics experiment measuring hundreds to thousands of pro- teins/protein groups is now commonplace. While expert practitioners who best understand the operation of LC-MS systems tend to have strong backgrounds in physics and engineering, consumers of proteomics data and technology are not exposed to the physio-chemical principles underlying the information they seek. Since articles and reviews tend not to focus on bridging this divide, our goal here is to span this gap and translate MS ion physics into language intuitive to the general reader active in basic or applied biomedical research. Here, we visually describe what happens to ions as they enter and move around inside a mass spectrometer. We describe basic MS principles, including electric current, ion optics, ion traps, quadrupole mass filters, and Orbitrap FT-analyzers.
    [Show full text]
  • Arxiv:1512.05503V4 [Physics.Plasm-Ph] 14 Mar 2016
    Multipole Electrodynamic Ion Trap Geometries for Microparticle Confinement Multipole Electrodynamic Ion Trap Geometries for Microparticle Confinement under Standard Ambient Temperature and Pressure Conditions Bogdan M. Mihalcea,1, a) Liviu C. Giurgiu,2 Cristina Stan,3 Gina T. Vi¸san,1 Mihai Ganciu,1 Vladimir E. Filinov,4 Dmitry Lapitsky,4, b) Lidiya Deputatova,4 and Roman Syrovatka4 1)National Institute for Laser, Plasma and Radiation Physics (INFLPR), Atomi¸stilorStr. Nr. 409, 077125 M˘agurele, Ilfov, Romania 2)University of Bucharest, Faculty of Physics, Atomistilor Str. Nr. 405, 077125 M˘agurele, Romania 3)Department of Physics, Politehnica University, 313 Splaiul Independent¸ei, RO-060042, Bucharest, Romania 4)Joint Institute for High Temperatures, Russian Academy of Sciences, Izhorskaya Str. 13, Bd. 2, 125412 Moscow, Russia Trapping of microparticles and aerosols is of great interest for physics and chemistry. We report microparticle trapping in case of multipole linear Paul trap geometries, operating under Standard Ambient Temperature and Pressure (SATP) conditions. An 8-electrode and a 12-electrode linear trap geometries have been designed and tested with an aim to achieve trapping for larger number of particles and to study microparticle dynamical stability in electrodynamic fields. We report emergence of planar and volume ordered structures of microparticles, depending on the a.c. trap- ping frequency and particle specific charge ratio. The electric potential within the trap is mapped using the electrolytic tank method. Particle dynamics is simulated using a stochastic Langevin equation. We emphasize extended regions of stable trap- ping with respect to quadrupole traps, as well as good agreement between experiment and numerical simulations.
    [Show full text]
  • Quadrupole and Ion Trap Mass Analysers and an Introduction to Resolution a Simple Definition of a Mass Spectrometer
    Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution A simple definition of a Mass Spectrometer ◗ A Mass Spectrometer is an analytical instrument that can separate charged molecules according to their mass–to–charge ratio. The mass spectrometer can answer the questions “what is in the sample” (qualitative structural information) and “how much is present” (quantitative determination) for a very wide range of samples at high sensitivity Components of a Mass Spectrometer Atmosphere Vacuum System Sample Ionisation Mass Data Detector Inlet Method Analyser System How are mass spectra produced ? ◗ Ions are produced in the source and are transferred into the mass analyser ◗ They are separated according to their mass/charge ratio in the mass analyser (e.g. Quadrupole, Ion Trap) ◗ Ions of the various m/z values exit the analyser and are ‘counted’ by the detector What is a Mass Spectrum ? ◗ A mass spectrum is the relative abundance of ions of different m/z produced in an ion source -a “chemical fingerprint” ◗ It contains – Molecular weight information (generally) – Structural Information (mostly) – Quantitative information What does a mass spectrum look like ? ◗ Electrospray mass spectrum of salbutamol + 100 MH 240 OH NH tBu HO Base peak HO % at m/z 240 241 0 60 80 100 120 140 160 180 200 220 240 260 280 300 What information do you need from the analysis ? ◗ Low or High Mass range ◗ Average or Monoisotopic mass (empirical) ◗ Accurate Mass ◗ Quantitation - precision, accuracy, selectivity ◗ Identification ◗ Structural Information
    [Show full text]
  • Specification Sheet: LTQ XL Linear Ion Trap Mass Spectrometer
    PRODUCT SPECIFICATIONS The Thermo Scientific™ LTQ XL™ linear ion trap mass spectrometer Everyday affordability with MSn The LTQ XL linear ion trap mass spectrometer delivers high sensitivity full Keywords scan MS along with in-depth MSn (CRM) capabilities. LTQ XL linear ion trap mass If you are in the market for an extremely affordable general-purpose mass n spectrometer, MS (CRM) spectrometer, look no further than the LTQ XL. capabilities, proteomics, metabolite identification, forensic analysis, Applications include proteomics, metabolite identification, forensic analysis, clinical research, teaching clinical research and teaching. General purpose utility extends to users in academia, industry and government alike. Now includes updated software with Windows 10 compatibility enabling full support today and into the future A single quadrupole offers no more than Selected Ion Monitoring (SIM). A triple quadrupole adds Selected Reaction Monitoring (SRM) where a selected ion can be fragmented into a product ion. A linear ion trap goes further by enabling Consecutive Reaction Monitoring (CRM) where a selected ion is fragmented into a product ion and the resulting product ion further fragmented in additional consecutive steps (MSn). Each additional fragmentation step makes compound identification more certain and facilitates structural characterization. Selected Ion First Product Ion Second Product Ion (MS1) Fragmentation (MS2) Fragmentation (MS3) Powerful tools for structural characterization Collision Induced Dissociation (CID) • Resonance
    [Show full text]
  • Optimized DLP Linear Ion Trap for a Portable Non-Scanning Mass Spectrometer
    International Journal of Mass Spectrometry 369 (2014) 30–35 Contents lists available at ScienceDirect International Journal of Mass Spectrometry journa l homepage: www.elsevier.com/locate/ijms Optimized DLP linear ion trap for a portable non-scanning mass spectrometer a, a b c Boris Brkic *, Stamatios Giannoukos , Neil France , Robert Murcott , d a Fabrizio Siviero , Stephen Taylor a Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool L69 3GJ, United Kingdom b Q Technologies Ltd, 100 Childwall Road, Liverpool L15 6UX, United Kingdom c TWI Technology Centre Yorkshire, Advanced Manufacturing Park, Wallis Way, Catcliffe, Rotherham S60 5TZ, United Kingdom d Vacuum Technology Lab, SAES Getters S.p.A., Viale Italia 77, Lainate 20020, Milan, Italy A R T I C L E I N F O A B S T R A C T Article history: This work reports implementation of an optimized linear ion trap (LIT) mass analyzer manufactured Received 7 April 2014 using digital light processing (DLP), a low cost rapid prototyping technique. To satisfy requirements for a Received in revised form 23 May 2014 portable commercial instrument, our previous DLP LIT has been improved by using polymer material for Accepted 2 June 2014 electrodes and housing with higher heat deflection temperature and much improved metal coating of the Available online 4 June 2014 electrodes. In this way, a polymer-based LIT can operate at higher pressures with more stable voltages, low outgassing and with much longer electrode lifetime. This paper demonstrates non-scanning Keywords: operation of a DLP LIT based on ceramic resin with specially electroplated electrodes.
    [Show full text]
  • Investigations on Dynamical Stability in 3D Quadrupole Ion Traps
    applied sciences Article Investigations on Dynamical Stability in 3D Quadrupole Ion Traps Bogdan M. Mihalcea 1,* and Stephen Lynch 2 1 National Institute for Laser, Plasma and Radiation Physics (INFLPR), Atomi¸stilorStr. Nr. 409, 077125 M˘agurele, Romania 2 Department of Computing and Mathematics, Manchester Metropolitan University, Manchester M1 5GD, UK; [email protected] * Correspondence: bogdan.mihalcea@inflpr.ro; Tel.: +40-21-4574437 Abstract: We firstly discuss classical stability for a dynamical system of two ions levitated in a 3D Radio-Frequency (RF) trap, assimilated with two coupled oscillators. We obtain the solutions of the coupled system of equations that characterizes the associated dynamics. In addition, we supply the modes of oscillation and demonstrate the weak coupling condition is inappropriate in practice, while for collective modes of motion (and strong coupling) only a peak of the mass can be detected. Phase portraits and power spectra are employed to illustrate how the trajectory executes quasiperiodic motion on the surface of torus, namely a Kolmogorov–Arnold–Moser (KAM) torus. In an attempt to better describe dynamical stability of the system, we introduce a model that characterizes dynamical stability and the critical points based on the Hessian matrix approach. The model is then applied to investigate quantum dynamics for many-body systems consisting of identical ions, levitated in 2D and 3D ion traps. Finally, the same model is applied to the case of a combined 3D Quadrupole Ion Trap (QIT) with axial symmetry, for which we obtain the associated Hamilton function. The ion distribution can be described by means of numerical modeling, based on the Hamilton function Citation: Mihalcea, B.M.; Lynch, S.
    [Show full text]
  • CHAPTER 5 Mass Spectrometry, Cont'd Part 2
    CHAPTER 5 Mass Spectrometry, Cont’d Part 2 5.2.6.3 Quadrupole ion trap mass filter: While the operation of the ion trap was characterized shortly after the linear quadrupole in 1960 by Paul and Steinwedel, its application in the chemical laboratory was severely limited. This was due to difficulties associated with manufacturing a circular electrode and performance problems. These performance problems were overcome when a group at Finnigan MAT lead by Stafford discovered two breakthroughs that lead to the production of a commercially available ion trap mass filter. The first ion trap developed used a mode of operation where a single mass could be stored in the trap when previously all of the ions had to be stored. Their next important discovery was the ability for 1 mtorr of helium gas to improve the instruments resolution. The helium molecules’ collisions with the ions reduced their kinetic energy and subsequently focused them towards the center of the trap. After these initial hurdles were cleared, many new techniques were developed for a diverse set of applications especially in biochemistry. This is a result of its comparative advantage over the quadrupole when analyzing high molecular mass compounds (up to several thousand m/z units) to unit resolution in commonly encountered instruments. The ion trap is also an extremely sensitive instrument that allows a molecular weight to be determined with a small number of molecules. The ion trap is also the only mass filter that can contain ions that need to be analyzed for any significant duration of time. This allows the instrument to be particularly useful in monitoring the kinetics of a given reaction.
    [Show full text]
  • Mass Analyzers Ion Movement
    Mass Analyzers Árpád Somogyi CCIC MSP OSU Summer Workshop Ion movement • Biased metal plates (electrodes, lenses) used to move ions between ion source and analyzers • Electrodes and physical slits used to shape and restrict ion beam • Good sensitivity is dependent on good ion transmittance efficiency in this area Ionization Mass Detector source analyzer inlet all ions sorted Data ions system 1 Ion detection • Ions can be detected efficiently w/ high amplification by accelerating them into surfaces that eject electrons Ionization Mass Detector source analyzer inlet all ions sorted Data ions system Detectors TOF 2 Ion energy • Kinetic energy of ions defined by E = zeV = qV = ½ mv2 E = kinetic energy m = mass v = velocity e = electronic charge (1.60217e-19 C) z = nominal charge V = accelerating voltage Learning Check Consider two electrodes, one at 1000 V and one at ground (0 V) 1000 V0 V + ion will travel with kinetic energy of ___________ 3 Question: Consider an ion source block and an extraction lens. How would you bias the block and lens if you want the ions to be accelerated by a) 8000 eV (appropriate for magnetic sector) b) 5 eV (appropriate for entering a quadrupole) c) 20,000 eV (appropriate for entering a TOF) Notice: accelerating voltages vary with analyzer (has consequences for MS/MS) • High voltage (keV energy range) – magnet (B) – electrostatic (E) – time-of-flight (TOF) • Low voltage (eV energy range) – quadrupole (Q) – ion trap (IT, LT, OT) – ion cyclotron resonance (ICR) 4 Mass Resolution • Mass spectrometers separate ions with a defined resolution/resolving power • Resolving power- the ability of a mass spectrometer to separate ions with different mass to charge (m/z) ratios.
    [Show full text]
  • Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer Ailin Li Brigham Young University
    Brigham Young University BYU ScholarsArchive All Theses and Dissertations 2017-08-01 Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer Ailin Li Brigham Young University Follow this and additional works at: https://scholarsarchive.byu.edu/etd Part of the Chemistry Commons BYU ScholarsArchive Citation Li, Ailin, "Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer" (2017). All Theses and Dissertations. 6503. https://scholarsarchive.byu.edu/etd/6503 This Dissertation is brought to you for free and open access by BYU ScholarsArchive. It has been accepted for inclusion in All Theses and Dissertations by an authorized administrator of BYU ScholarsArchive. For more information, please contact [email protected], [email protected]. Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer Ailin Li A dissertation submitted to the faculty of Brigham Young University in partial fulfillment of the requirements for the degree of Doctor of Philosophy Daniel E. Austin, Chair Matthew C. Asplund David V. Dearden Steven R. Goates Jaron C. Hansen Department of Chemistry and Biochemistry Brigham Young University Copyright © 2017 Ailin Li All Rights Reserved ABSTRACT Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer Ailin Li Department of Chemistry and Biochemistry, BYU Doctor of Philosophy I describe the miniaturization of a linear-type ion trap mass spectrometer for possible applications in portable chemical analysis, and demonstrate the advantages of using lithographically patterned electrode plates in realizing an ion trap with dimension r0 less than 1 mm.
    [Show full text]