Doors and Windows Section 07200 Insulation
Total Page:16
File Type:pdf, Size:1020Kb
AL FATEH UNIVERSITY ODAC Division 08 Doors and Windows Section 07200 Insulation GENERAL SPECIFICATIONS FOR BUILDING CONSTRUCTION DIVISION 08: DOORS AND WINDOWS 1 Al LABINA / AL MANAR in partnership with Hamza/ ECH/ LCE JV AL FATEH UNIVERSITY ODAC Division 08 Doors and Windows Section 07200 Insulation Foreword The internationally recognized framework known as “Masterformat” released by the Construction Specifications Institute (CSI) has been adopted in order to organize the sorting and numbering in the new edition of the specifications in a manner that insures the easy flow and exchange of information among specialists and the community of the building industry at large. The new edition involves 12 main divisions. These divisions are: Division 01: General Requirements Division 02: Site work Division 03: Concrete Division 04: Masonry Division 05: Metals Division 06: Wood and Plastics Division 07: Thermal and Moisture Protection Division 08: Doors and Windows Division 09: Finishes Division 14: Conveying Systems Division 15: Mechanical Division 16: Electrical Each Division comprises a number of related Sections. For example: Division 08 includes eight sections. They are: 08100 Doors and Frames 08200 Wooden and Plastic Doors 08300 Special Doors 08400 Entrances and Storefronts 08500 Metal Windows 08600 Wooden and Plastic Windows 08700 Hardware 08800 Glazing 2 Al LABINA / AL MANAR in partnership with Hamza/ ECH/ LCE JV AL FATEH UNIVERSITY ODAC Division 08 Doors and Windows Section 07200 Insulation Further, each Section incorporates seven Parts as follows: Part 1: General: This is mainly concerned with the references, quality control, submittals, programs, and maintenance. Part 2: Products: This gives a breakdown of material used in addition to their properties and place of installation. Part 3: Execution: The most significant items in this Part are the execution and installation of the works, field quality control, as well as cleaning and protection methods. Part 4: Methods of Measurement: This indicates the measurement units and the measuring methods that shall be used for the Bills of Quantities. Part 5: Basis of Payment: This indicates the work that shall be completed for each item of the Bills of Quantities. It also indicates the ancillary works to be included in the unit price rate. Part 6: Annex: Tables and Figures: Those relevant to the individual Section. Comments and Recommendations may be forwarded to the following address: 3 Al LABINA / AL MANAR in partnership with Hamza/ ECH/ LCE JV AL FATEH UNIVERSITY ODAC Division 08 Doors and Windows Section 07200 Insulation DIVISION 08 DOORS AND WINDOWS 4 Al LABINA / AL MANAR in partnership with Hamza/ ECH/ LCE JV AL FATEH UNIVERSITY ODAC Division 08 Doors and Windows Section 07200 Insulation INDEX Division 01: General Requirements Division 02: Sitework Division 03: Concrete Division 04: Masonry Division 05: Metals Division 06: Wood & Plastics Division 07: Thermal & Moisture Protection Division 08: Doors & Windows 08100 Metal Doors and Frames 08200 Wood and Plastic Doors 08300 Special Doors 08400 Entrances and Storefront 08500 Metal Windows 08600 Wood and Plastic Windows 08700 Hardware 08800 Glazing Division 09: Finishes Division 14: Conveying Systems Division 15: Mechanical Division 16: Electrical 5 Al LABINA / AL MANAR in partnership with Hamza/ ECH/ LCE JV AL FATEH UNIVERSITY ODAC Division 08 Doors and Windows Section 07200 Insulation 6 Al LABINA / AL MANAR in partnership with Hamza/ ECH/ LCE JV AL FATEH UNIVERSITY ODAC H11 CURTAIN WALLING H11 CURTAIN WALLING To be read in conjunction with General Requirements. TYPES OF CURTAIN WALLING 110 CURTAIN WALLING TO ALL FACADES – Type CW1 and CW2 - Supporting structure: In situ reinforced concrete frame. floor and roof decks. - Curtain walling system: - Manufacturer & reference: Schuco International KG, Whitehall Avenue, Kingston, Milton Keynes, Buckinghamshire, UK Tel: 044 908 282 111 Fax: 044 908 282124 or equal and approved. - Type: Thermally broken stick system. To include all products, fixings and interfaces necessary to complete the fabrication and installation. Performance criteria to comply with Design/Performance Requirements and Testing subsections. - Internal framing member: - Material: Aluminium as clause 710. - Finish: Polyester powder coated as section Z31. Colour/ texture: RAL Colour to be agreed. 80% gloss/20% matt. Minimum film thickness: As section Z31 - External cover cap: - Material: Aluminium as clause 710. - Finish: Polyester powder coated as section Z31. Colour/ texture: RAL Colour to be agreed. 80% gloss/20% matt Minimum film thickness: As section Z31 - Glazing type: Hermetically sealed double glazed units with 16mm minimum cavity. - Inner pane: 6mm thick low emmissivity clear float glass. (Toughened safety glass where required) - Outer pane: 8mm thick Laminated solar control glass. - Glazing system: Double glazed gasketed system. 137 DOORSETS TO GLAZED SCREENS - As L20/482. - GENERAL REQUIREMENTS/ PREPARATORY WORK 210 DESIGN - Complete the detailed design of the curtain walling and associated features to meet the requirements of this specification. - Co-ordinate detailed design with that for all related works. 215 DESIGN PROPOSALS - The general arrangement drawings indicate design intent but do not preclude submission with the tender of reasonable alternative proposals for consideration. 1 Al LABINA / AL MANAR in partnership with Hamza/ ECH/ LCE JV AL FATEH UNIVERSITY ODAC H11 CURTAIN WALLING 220 SPECIFICATION - Comply with the latest edition of the Centre for Window and Cladding Technology (CWCT) ‘Standard for curtain walling’ unless specified otherwise in this section. - Keep a copy of the CWCT ‘Standard for curtain walling’ at the design office, workshop and on site, readily accessible for reference at all times during the course of the works. 231 INFORMATION TO BE PROVIDED AFTER ACCEPTANCE OF TENDER - Submit to the CA within 4 weeks of appointment the following curtain walling particulars: - A schedule of detailed drawings and dates for submission for comment. - A schedule of loads that will be transmitted from the curtain walling to the structure. - Proposed fixing anchor details relevant to structural design and construction. - A detailed testing programme in compliance with the Main Contract master programme. - A detailed fabrication and installation programme in compliance with the Main Contract master programme. - A quality plan in compliance with CWCT ‘Guide to good practice for facades’, Section 6. - Proposals to support any outstanding applications for Building Regulation consents or relaxations and thereby obtain approval. 232 DESIGN AND PRODUCTION INFORMATION Submit the following curtain walling particulars: - Typical plan, section and elevation drawings at suitable scales. Typical detailed drawings at large scales, including details showing the incorporation of doorsets, casement window inserts and associated jamb, head and sill flashings as shown on the indicative design drawings. - Technical information and certification demonstrating compliance with specification of proposed incorporated products and finishes. - Certification, reports and calculations demonstrating compliance with specification of proposed curtain walling. - Proposals for connections to and support from the building structure and building components. - Proposals for amendments to primary supporting structure and for secondary supporting structure additional to that shown on preliminary design drawings. - Schedule of builder’s work, special provisions and special attendance by others. - Examples of standard documentation from which project quality plan will be prepared. - Preliminary fabrication and installation method statements and programme. - Schedule of products and finishes with a design life expectancy less than that specified in clause 440, with proposals for frequencies and methods of replacement. - Proposals for replacing damaged or failed products. - Design and detailing: 2 Al LABINA / AL MANAR in partnership with Hamza/ ECH/ LCE JV AL FATEH UNIVERSITY ODAC H11 CURTAIN WALLING - Complete the design and detailing of the work and provide complete production information (including as appropriate, fabrication/installation drawings, all design calculations, specifications etc.) based on the drawings, this specification and other information provided, liasing with the CA, and others as necessary to help ensure co-ordination of the work with related building elements and services. - Information: - Request additional information as necessary from the CA and provide information as necessary in time to meet the programme. - Submission: - Submit sufficient copies of the design/production information, including copies for the CA and consultants. - Inspection by the CA: - The CA will inspect the design/production information, record his comments and return to the Contractor within the period stated on the Form of Tender. - Amendments: - Make any necessary amendments without delay. Unless and until it is confirmed that the resubmission is not required, resubmit for further review and comment, and incorporate any necessary amendments all as before. - Variations: - If submitted design/production information differs from the Subcontract/Tender/Contract documents each such difference must be the subject of a request for substitution or Variation, supported by all relevant information. - Amendments required by CA: - Should any amendment to design/production information required by the CA be considered to involve a Variation which