Ensures more accurate and more reliable thermal control of the specimens during the observation under a microscope. Wide product range supports Biotechnology Science and Industry. Thermoplate provides user comfort with High Quality and High Performance.
Ensures more accurate and more reliable thermal control of the specimens during the observation under a microscope. Wide product range supports Biotechnology Science and Industry.
Microscope-Stage Automatic Thermocontrol System series High Quality & High Performance Stylish & Smart Which is your color ? More accurate, More stable !
Environmentally and user-friendly design Along with its great functionality and high performance, TP’s new design creates a warm, relaxed lab environment. Five color variations are available. Please choose your color!
Colorful controller makes lab comfortable!
Clear Glass Heater The Thermoplate utilizes a special transparent heating material coated onto a hard glass. The Thermoplate can be used for observing or manipulating specimen under phase contrast and polarization. The flat plate surface ensures easy operation of the microscopes and relocation of specimen.
Five colors are available only for standard glass plate and lens heater.
Imaging Preset temperature: from room temperature to 50℃
Especially recommended for use when using high-magnification lenses and oil/water immersion lenses
※To prevent heat from escaping to objectives, we recommend use in combination with lens heater. ※For short-term imaging In case of long-term imaging, Stage Top Incubator is recommended.
Dimensions of controller (mm) : W98mm × D145mm × H117m Lens Heater 1 INDEX Smart Enables ease of temperature measurement 1 Monitor selector switch Sterilized sensor Heater temperature ⇆ (external) Sterilized sensor can measure OLYMPUS OLYMPUS the actual sample temperature. Sensor temperature Also, it enables on-site calibration Inverted to provide optimal temperature Upright setting at your laboratory. Stereo
※ Significantly enhance Quality Control!
Nikon Inverted Nikon Upright Stereo Smart2Temperature Management Software TEM Monitors, records and logs sample or plate temperature which the sensor measures. ZEISS Inverted ZEISS / Leica Saves data in CSV format which can be used in spreadsheets. Upright Stereo ※ Significantly enhance Quality Control! Leica Inverted Upright Stereo KEYENCE KEYENCE Smart Stable imaging, effective for high magnification Inverted
3 / Marzhauser Continuous Current Control All Makers Other Makers In addition to PID control, TP features On-Off Control Ludl Continuous Current Control, minimizing Prior focus drift generated by heat compared to the standard On-Off control method. Especially effective for observation when high magnification is required.
Thermoplate provides uniform temperature distribution!
An image taken by the thermal camera
Cooling and Heating Preset temperature: from 4℃ to 60℃ Handles wide range of observations: yeast, plants, marine life, cell cultures, C.elegans, Planaria etc
The application of a thermoelectric cooling device and unique control system produces a compact and highly responsive cooling and heating system. Chiller Unit Temperature Controller
2 OLYMPUS Standard ( Glass plate ・Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0/1.3/1.6mm uniform or 0.5mm at plate center (50x50mm))
Applicable microscopes Applicable microscopes
□50
Nikon Inverted IX83/73 Upright Power BX/ BX (U-SVLO/SVRO/SVLB-4/SVRB-4) IX81/71/51 □70 φ110 IX70/50 BH2 IMT2 CX40
cross stage Model Glass thickness CH40/30 round opening: φ110mm TP-110R05 0.5mm TP-110R 1.0mm
TP-110R13(with white line) TP-110R13 1.3mm
Applicable microscopes
ZEISS / Leica IX83/73 □50 155 XY manual stage 130 (IX3-SVR) 189.5 155.5 XY motorized stage (IX3-SSU) 4.5 Model Glass thickness Sub stage TP-IX3-05 0.5mm for opening: 156mm x 190mm Other Makers All Makers ( ) TP-IX3 1.0mm /
Applicable microscopes Model Glass thickness
□50 CKX41/31 TP-S 1.0mm 127 KEYENCE CK40/30/2 85
XY mechanical stage 8 Model Glass thickness TP-CK05 0.5mm
TP-CK 1.0mm 128 142 95 115
□50 5
150 53 14 53
110 4 9 Model Glass thickness Installation Plate TP-CKTS05 0.5mm Fix glass heating plate on the side by TP-CKTS 1.0mm(for well plate use) using attached double sided tape ※For other motorized stages, please refer to P9. Cooling and Heating (Metal plate with a hole・Preset Temperature: 4℃~ 60℃)
Applicable microscopes Applicable microscopes IX83/73 Power BX/ BX Inverted IX81/71/51 Upright (U-SVLO/SVRO/SVLB-4/SVRB-4) IX70/50 BH2 IMT2 CX40 cross stage CH40/30 round opening: φ110mm 40 10 40 4
TP-CH110R-C Φ20 Φ110 Φ20
101 101 110 110 Installation Plate Φ20 Fix metal plate on the side
Model 9 by magnets TP-CH110R-C Model for 35mm dish and slide glass TP-CH110RBF-C 76 27 TP-CHS-C Φ42
Φ116 TP-CH110RBF-C 3 OLYMPUS
Applicable microscopes Applicable microscopes Nikon MVX10 SZX16/SZX10 Stereo SZX16/SZX10 SZX2-ILLT SZX2-ILLB SZX2-ILLK SZX2-ILLD
Model Glass thickness Model Glass thickness ZEISS / Leica
TP-SZX2A 1.0mm 207 TP-SZX2B 1.0mm 212 152 152
162 162 278 236 7 7 Applicable microscopes Applicable microscopes
MVX10 SZX7/SZ61 KEYENCE SZX12/9/7 SZ2-ST + SZ2-ILA SZX-ILLK
SZX-ILLB2 / All Makers Other Makers SZX-ILLD2
Model Glass thickness Model Glass thickness
TP-SZX 1.0mm TP-SZ2 1.0mm 175 □205 146 □170
230
278 7 10
Applicable microscopes 211 175 Universal
430 75 ~ 100 400
Model Glass thickness TP-UNI 1.6mm 10
Imaging (Metal plate with a hole・ Preset Temperature: room temperature ~ 50℃)
Applicable microscopes Applicable microscopes IX83/73 IX83/73 Inverted XY manual stage IX81/71/51 (IX3-SVR) IX70/50 XY motorized stage IMT2 (IX3-SSU) cross stage round opening: φ110mm Sub stage Φ26 (for opening: 156mm x 190mm)
156 Φ26 131 189.5 φ110
155.5 4.5 Model Model TP-110RH26 TP-IX3H26 When using Imaging plate, we recommend to use with Lens heater. ( Please refer to P10.) 4 OLYMUPS Standard ( Glass plate・ Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0/1.6mm uniform or 0.5mm at plate center (50x50mm))
Applicable microscopes Applicable microscopes
□50 Nikon Ti Ni Inverted Upright TE2000/300/200 □70 Ci φ108 TMD300/200 90i/80i/55i/50i Rectangular stage E1000/800/600/400/200 round opening: φ108mm Model Glass thickness TP-108R05 0.5mm OPTIPHOT-2 LABOPHOT-2
Applicable microscopes □50 TS100/TS100-F mechanical stage 130 97.5 ZEISS / Leica 5.5
Model Glass thickness TP-TS05 0.5mm
Model Glass thickness
□50 TP-S 1.0mm Other Makers All Makers /
150
110 9
KEYENCE Model Glass thickness 128
TP-CKTS05 0.5mm 142 95 115 TP-CKTS 1.0mm(for well plate use) 5
Applicable microscopes 53 14 53 TMS/TMS-F □50 4 mechanical stage 130 Installation Plate 90 Fix glass heating plate on the side by using attached double sided tape 5.5
Model Glass thickness TP-TMS05 0.5mm TP-TMS 1.0mm ※For other motorized stages, please refer to P9. Cooling and Heating (Metal plate with a hole・Preset Temperature: 4℃~ 60℃)
Applicable microscopes Applicable microscopes Ti Ni Inverted TE2000/300/200 Upright Ci TMD300/200 90i/80i/55i/50i Rectangular stage E1000/800/600/400/200 round opening: φ108mm OPTIPHOT-2
TP-CH108R-C LABOPHOT-2 40 10 40 4 Φ108 Φ20
Φ20
101 110 101 Installation Plate Φ20 110 Model Fix metal plate on the side by magnets TP-CH108RBF-C TP-CHS-C 9 Model TP-CH108R-C 76 27 TP-CH108RBF-C for 35mm dish and slide glass Φ42 Φ116 5 OLYMPUS Nikon
Applicable microscopes Stand models: C-DSD
234 Stereo SMZ1500/1000/800 C-DSS C-BD
175 185
254
Model Glass thickness ZEISS / Leica TP-SMZSL 1.0mm 9 Stand models: C-PS
229 169 C-DS
145
198
Model Glass thickness KEYENCE TP-SMZSS 1.0mm 7 / All Makers Other Makers
φ180
Model Glass thickness
6.7 TP-SMZR 1.0mm
Applicable microscopes 211 175 Universal
430 75 ~ 100 400 Model Glass thickness TP-UNI 1.6mm
10
Imaging (Metal plate with a hole ・Preset Temperature: room temperature ~ 50℃)
Applicable microscopes Applicable microscopes Ti Ti Inverted TE2000/300/200 Exclusive XY motorized stage
TMD300/200 When installing without Piezo stage, the Rectangular stage stage adapter TID-NA is required. round opening: φ 108mm
Φ26 Φ26 129 159.5
φ108 87 109.5 4
Model Model TP-108RH26 TP-TIZH26
When using Imaging plate, we recommend to use with Lens heater. ( Please refer to P10.) 6 Standard ( Glass plate・ Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0/1.6mm uniform or 0.5mm at plate center (50x50mm))
Applicable microscopes Applicable microscopes
86
Inverted Axio Observer Upright □ Axio Examiner Axiovert 50 130 Axio Imager (K type frame holder) 160 110 Axiophot2 Axioplan2 Model Glass thickness Axioskop TP-SQ05 0.5mm Axiolab
OLYMPUS TP-SQ 1.0mm Axiolab Pol Axiolab Imager
□ 50
135 160
89 110 3
Nikon Model Glass thickness TP-SQ05FT 0.5mm(flat type)
Model Glass thickness TP-S 1.0mm
Applicable microscopes
□ Axio Observer 50
130
Axiovert 165 128 86 142 95 105 (M type frame holder) 115 3
Model Glass thickness 5
ZEISS / Leica 53 14 53 TP-SQM05 0.5mm
TP-SQM 1.0mm 4 Installation Plate Fix glass heating plate on the side by using attached double sided tape Other Makers All Makers / KEYENCE
Cooling and Heating (Metal plate with a hole・ Preset Temperature: 4℃~ 60℃)
Applicable microscopes Applicable microscopes Axio Observer Axio Observer Inverted Axiovert Axiovert (K type frame holder) (M type frame holder)
φ2 0
φ2 0
83
160 165 30
φ68 Φ6 8 100 110 12 4.5 Model Model TP-CHSQ-C TP-CHSQM -C
models for Leica microscopes are exclusively distributed through Leica worldwide network the name of ''Leica MATS''
7 Applicable microscopes
Stereo Axio Discovery Stemi2000 (with large base stand N: 495052 9801) 136 185 160 210 OLYMPUS
7 Model Glass thickness TP-ST2 1.0mm
Applicable microscopes
89 Stemi2000 (with transmitted light base stand N: 455137)
113 155
Model Glass thickness
TP-STR 1.0mm Nikon
Applicable microscopes
423.5 Discovery.V12 300 Lumar.V12 8
150 Model Glass thickness
251.5 ZEISS / Leica TP-V12 1.0mm
Applicable microscopes 211 175 Universal
430 75 ~ 100 400
Glass thickness
Model KEYENCE
10 TP-UNI 1.6mm / All Makers Other Makers
Imaging (Metal plate with a hole・Preset Temperature: room temperature ~ 50℃)
Applicable microscopes Applicable microscopes Axio Examiner Axio Observer Upright Axio Imager Inverted Axiovert Axiophot2 (K type frame holder) Axioplan2
Axioskop 40 10 40 Φ26
Axiolab 4 Axiolab Pol Φ2 0 130 Installation Plate 101 160 Axiolab Imager 110 101 86 110 Fix metal plate on the side 110 by magnets 3 9 Model Model TP-CHS -C TP-SQH26
models for Leica microscopes are exclusively distributed For more information about "Imaging" and "Cooling and Heating" plates for Leica microscopes, through Leica worldwide network the name of ''Leica MATS'' please feel free to contact Tokai Hit at [email protected]
8 KEYENCE Other Makers Standard ( Glass plate ・Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0mm uniform or 0.5mm at plate center (50x50mm)) Marzhauser / Ludl
Applicable stage XY moterized stage 86 opening: 110mm × 160mm
□ 50
130
OLYMPUS 160
110
Model Glass thickness TP-SQ05 0.5mm TP-SQ 1.0mm
Nikon Prior
Applicable stage
□ H117 50
160
110 3
Model Glass thickness Applicable stage TP-SQP05 0.5mm BZ-8000 TP-SQP 1.0mm
ZEISS / Leica BZ-9000 H101 Applicable stage
130
160 87
□50 110
φ110 3 Other Makers All Makers /
Model Glass thickness Model Glass thickness TP-KI05 0.5mm TP-SQUP 1.0mm KEYENCE Cooling and Heating (Metal plate with a hole・Preset Temperature: 4℃~ 60℃) Marzhauser / Ludl Applicable stage Applicable stage φ2 0 φ116 BZ-8000 φ20 78 XY moterized stage BZ-9000 opening: 110mm × 160mm
27 160
Φ6 8 110
Model Model 4.5 TP-CHKI-C TP-CHSQ-C
Imaging (Metal plate with a・hole Preset Temperature: room temperature ~ 50℃) Marzhauser / Ludl Applicable stage Applicable stage BZ-8000 XY moterized stage φ26 opening: 110mm × 160mm Φ2 6 130 BZ-9000 φ110 160 86
110 3 Model
Model TP-SQH26 TP-KIH26 Prior
Φ26
Applicable stage 130 160
86 H117 110 3 Model TP-SQH26P
9 KEYENCE / Other Makers / All Makers All Makers Others
Lens Heater Velcro Tape OLYMPUS
Ease of set-up and superior 140 Power supply cord thermal effectiveness
55 Prevents heat from escaping 35 15 17 to objectives when using high magnification lenses and oil/water immersion lenses. Heater Model TP-LH Nikon
Digital Thermometer Thermoprobe for Bioresearch Model TSU-200F Model MC1000 (Stand alone sensor type) (For K type thermocouple) 1.0mm diameter sensor Sensor is calibrated to thermometer ZEISS / Leica probe coated with Teflon as a set, which enables precise for high chemical-resistance temperature measurement. KEYENCE Tip width : 2.0 ~ 2.5mm Tip thickness : 0.3 ~ 0.5mm / All Makers Other Makers
Option series
Dish fixing flat springs Model CL
Thermo sensor fixing guide Model TSU-G For Imaging, Cooling and Heating plate, CL is included as standard. TP option can be installed only for Inverted microscopes.
Repair Service
To expedite repair service, the following information is required: ・Serial number of plate and controller ・Photo of the defective unit ( F o r example, broken plate) ・User name, address, etc.
Please feel free to contact to Tokai Hit at [email protected] with the above information.
Your Satisfaction is Our Mission. We pay attention to your each and every word. Whenever you require our assistance, please feel free to contact us anytime.
10 306-1Gendoji-cho, Fujinomiya-shi, Shizuoka-ken, Japan 418-0074 TELEPHONE:(81)-544-24-6699 FAX:(81)-544-24-6641 Email:[email protected]
Catalog printed March 2013 Specifications and products in the catalog are subject to change without any obligation on the part of the distributor/ manufacturer.
▲Please pay special attention to items marked with Caution and Warning symbols as seen on the left. It is essential to read the Instruction Manual when using this device. TH-QB1452