Microscope-Stage Automatic Thermocontrol System

Total Page:16

File Type:pdf, Size:1020Kb

Microscope-Stage Automatic Thermocontrol System Microscope-Stage Automatic Thermocontrol System Ensures more accurate and more reliable thermal control of the specimens during the observation under a microscope. Wide product range supports Biotechnology Science and Industry. Thermoplate provides user comfort with High Quality and High Performance. Ensures more accurate and more reliable thermal control of the specimens during the observation under a microscope. Wide product range supports Biotechnology Science and Industry. Microscope-Stage Automatic Thermocontrol System series High Quality & High Performance Stylish & Smart Which is your color ? More accurate, More stable ! Environmentally and user-friendly design Along with its great functionality and high performance, TP’s new design creates a warm, relaxed lab environment. Five color variations are available. Please choose your color! Colorful controller makes lab comfortable! Clear Glass Heater The Thermoplate utilizes a special transparent heating material coated onto a hard glass. The Thermoplate can be used for observing or manipulating specimen under phase contrast and polarization. The flat plate surface ensures easy operation of the microscopes and relocation of specimen. Five colors are available only for standard glass plate and lens heater. Imaging Preset temperature: from room temperature to 50℃ Especially recommended for use when using high-magnification lenses and oil/water immersion lenses ※To prevent heat from escaping to objectives, we recommend use in combination with lens heater. ※For short-term imaging In case of long-term imaging, Stage Top Incubator is recommended. Dimensions of controller (mm) : W98mm × D145mm × H117m Lens Heater 1 INDEX Smart Enables ease of temperature measurement 1 Monitor selector switch Sterilized sensor Heater temperature ⇆ (external) Sterilized sensor can measure OLYMPUS OLYMPUS the actual sample temperature. Sensor temperature Also, it enables on-site calibration Inverted to provide optimal temperature Upright setting at your laboratory. Stereo ※ Significantly enhance Quality Control! Nikon Inverted Nikon Upright Stereo Smart2Temperature Management Software TEM Monitors, records and logs sample or plate temperature which the sensor measures. ZEISS Inverted ZEISS / Leica Saves data in CSV format which can be used in spreadsheets. Upright Stereo ※ Significantly enhance Quality Control! Leica Inverted Upright Stereo KEYENCE KEYENCE Smart Stable imaging, effective for high magnification Inverted 3 / Marzhauser Continuous Current Control All Makers Other Makers In addition to PID control, TP features On-Off Control Ludl Continuous Current Control, minimizing Prior focus drift generated by heat compared to the standard On-Off control method. Especially effective for observation when high magnification is required. Thermoplate provides uniform temperature distribution! An image taken by the thermal camera Cooling and Heating Preset temperature: from 4℃ to 60℃ Handles wide range of observations: yeast, plants, marine life, cell cultures, C.elegans, Planaria etc The application of a thermoelectric cooling device and unique control system produces a compact and highly responsive cooling and heating system. Chiller Unit Temperature Controller 2 OLYMPUS Standard ( Glass plate ・Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0/1.3/1.6mm uniform or 0.5mm at plate center (50x50mm)) Applicable microscopes Applicable microscopes □50 Nikon Inverted IX83/73 Upright Power BX/ BX (U-SVLO/SVRO/SVLB-4/SVRB-4) IX81/71/51 □70 φ110 IX70/50 BH2 IMT2 CX40 cross stage Model Glass thickness CH40/30 round opening: φ110mm TP-110R05 0.5mm TP-110R 1.0mm TP-110R13(with white line) TP-110R13 1.3mm Applicable microscopes ZEISS / Leica IX83/73 □50 155 XY manual stage 130 (IX3-SVR) 189.5 155.5 XY motorized stage (IX3-SSU) 4.5 Model Glass thickness Sub stage TP-IX3-05 0.5mm for opening: 156mm x 190mm Other Makers All Makers ( ) TP-IX3 1.0mm / Applicable microscopes Model Glass thickness □50 CKX41/31 TP-S 1.0mm 127 KEYENCE CK40/30/2 85 XY mechanical stage 8 Model Glass thickness TP-CK05 0.5mm TP-CK 1.0mm 128 142 95 115 □50 5 150 53 14 53 110 4 9 Model Glass thickness Installation Plate TP-CKTS05 0.5mm Fix glass heating plate on the side by TP-CKTS 1.0mm(for well plate use) using attached double sided tape ※For other motorized stages, please refer to P9. Cooling and Heating (Metal plate with a hole・Preset Temperature: 4℃~ 60℃) Applicable microscopes Applicable microscopes IX83/73 Power BX/ BX Inverted IX81/71/51 Upright (U-SVLO/SVRO/SVLB-4/SVRB-4) IX70/50 BH2 IMT2 CX40 cross stage CH40/30 round opening: φ110mm 40 10 40 4 TP-CH110R-C Φ20 Φ110 Φ20 101 101 110 110 Installation Plate Φ20 Fix metal plate on the side Model 9 by magnets TP-CH110R-C Model for 35mm dish and slide glass TP-CH110RBF-C 76 27 TP-CHS-C Φ42 Φ116 TP-CH110RBF-C 3 OLYMPUS Applicable microscopes Applicable microscopes Nikon MVX10 SZX16/SZX10 Stereo SZX16/SZX10 SZX2-ILLT SZX2-ILLB SZX2-ILLK SZX2-ILLD Model Glass thickness Model Glass thickness ZEISS / Leica TP-SZX2A 1.0mm 207 TP-SZX2B 1.0mm 212 152 152 162 162 278 236 7 7 Applicable microscopes Applicable microscopes MVX10 SZX7/SZ61 KEYENCE SZX12/9/7 SZ2-ST + SZ2-ILA SZX-ILLK SZX-ILLB2 / All Makers Other Makers SZX-ILLD2 Model Glass thickness Model Glass thickness TP-SZX 1.0mm TP-SZ2 1.0mm 175 □205 146 □170 230 278 7 10 Applicable microscopes 211 175 Universal 430 75 ~ 100 400 Model Glass thickness TP-UNI 1.6mm 10 Imaging (Metal plate with a hole・ Preset Temperature: room temperature ~ 50℃) Applicable microscopes Applicable microscopes IX83/73 IX83/73 Inverted XY manual stage IX81/71/51 (IX3-SVR) IX70/50 XY motorized stage IMT2 (IX3-SSU) cross stage round opening: φ110mm Sub stage Φ26 (for opening: 156mm x 190mm) 156 Φ26 131 189.5 φ110 155.5 4.5 Model Model TP-110RH26 TP-IX3H26 When using Imaging plate, we recommend to use with Lens heater. ( Please refer to P10.) 4 OLYMUPS Standard ( Glass plate・ Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0/1.6mm uniform or 0.5mm at plate center (50x50mm)) Applicable microscopes Applicable microscopes □50 Nikon Ti Ni Inverted Upright TE2000/300/200 □70 Ci φ108 TMD300/200 90i/80i/55i/50i Rectangular stage E1000/800/600/400/200 round opening: φ108mm Model Glass thickness TP-108R05 0.5mm OPTIPHOT-2 LABOPHOT-2 Applicable microscopes □50 TS100/TS100-F mechanical stage 130 97.5 ZEISS / Leica 5.5 Model Glass thickness TP-TS05 0.5mm Model Glass thickness □50 TP-S 1.0mm Other Makers All Makers / 150 110 9 KEYENCE Model Glass thickness 128 TP-CKTS05 0.5mm 142 95 115 TP-CKTS 1.0mm(for well plate use) 5 Applicable microscopes 53 14 53 TMS/TMS-F □50 4 mechanical stage 130 Installation Plate 90 Fix glass heating plate on the side by using attached double sided tape 5.5 Model Glass thickness TP-TMS05 0.5mm TP-TMS 1.0mm ※For other motorized stages, please refer to P9. Cooling and Heating (Metal plate with a hole・Preset Temperature: 4℃~ 60℃) Applicable microscopes Applicable microscopes Ti Ni Inverted TE2000/300/200 Upright Ci TMD300/200 90i/80i/55i/50i Rectangular stage E1000/800/600/400/200 round opening: φ108mm OPTIPHOT-2 TP-CH108R-C LABOPHOT-2 40 10 40 4 Φ108 Φ20 Φ20 101 110 101 Installation Plate Φ20 110 Model Fix metal plate on the side by magnets TP-CH108RBF-C TP-CHS-C 9 Model TP-CH108R-C 76 27 TP-CH108RBF-C for 35mm dish and slide glass Φ42 Φ116 5 OLYMPUS Nikon Applicable microscopes Stand models: C-DSD 234 Stereo SMZ1500/1000/800 C-DSS C-BD 175 185 254 Model Glass thickness ZEISS / Leica TP-SMZSL 1.0mm 9 Stand models: C-PS 229 169 C-DS 145 198 Model Glass thickness KEYENCE TP-SMZSS 1.0mm 7 / All Makers Other Makers φ180 Model Glass thickness 6.7 TP-SMZR 1.0mm Applicable microscopes 211 175 Universal 430 75 ~ 100 400 Model Glass thickness TP-UNI 1.6mm 10 Imaging (Metal plate with a hole ・Preset Temperature: room temperature ~ 50℃) Applicable microscopes Applicable microscopes Ti Ti Inverted TE2000/300/200 Exclusive XY motorized stage TMD300/200 When installing without Piezo stage, the Rectangular stage stage adapter TID-NA is required. round opening: φ 108mm Φ26 Φ26 129 159.5 φ108 87 109.5 4 Model Model TP-108RH26 TP-TIZH26 When using Imaging plate, we recommend to use with Lens heater. ( Please refer to P10.) 6 Standard ( Glass plate・ Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0/1.6mm uniform or 0.5mm at plate center (50x50mm)) Applicable microscopes Applicable microscopes 86 Inverted Axio Observer Upright □ Axio Examiner Axiovert 50 130 Axio Imager (K type frame holder) 160 110 Axiophot2 Axioplan2 Model Glass thickness Axioskop TP-SQ05 0.5mm Axiolab OLYMPUS TP-SQ 1.0mm Axiolab Pol Axiolab Imager □ 50 135 160 89 110 3 Nikon Model Glass thickness TP-SQ05FT 0.5mm(flat type) Model Glass thickness TP-S 1.0mm Applicable microscopes □ Axio Observer 50 130 Axiovert 165 128 86 142 95 105 (M type frame holder) 115 3 Model Glass thickness 5 ZEISS / Leica 53 14 53 TP-SQM05 0.5mm TP-SQM 1.0mm 4 Installation Plate Fix glass heating plate on the side by using attached double sided tape Other Makers All Makers / KEYENCE Cooling and Heating (Metal plate with a hole・ Preset Temperature: 4℃~ 60℃) Applicable microscopes Applicable microscopes Axio Observer Axio Observer Inverted Axiovert Axiovert (K type frame holder) (M type frame holder) φ2 0 φ2 0 83 160 165 30 φ68 Φ6 8 100 110 12 4.5 Model Model TP-CHSQ-C TP-CHSQM -C models for Leica microscopes are exclusively distributed through Leica worldwide network the name of ''Leica MATS'' 7 Applicable microscopes Stereo Axio Discovery Stemi2000 (with large base stand N: 495052 9801)
Recommended publications
  • Experiment 5: Molar Volume of a Gas (Mg + Hcl)
    1 CHEM 30A EXPERIMENT 5: MOLAR VOLUME OF A GAS (MG + HCL) Learning Outcomes Upon completion of this lab, the student will be able to: 1) Demonstrate a single replacement reaction. 2) Calculate the molar volume of a gas at STP using experimental data. 3) Calculate the molar mass of a metal using experimental data. Introduction Metals that are above hydrogen in the activity series will displace hydrogen from an acid and produce hydrogen gas. Magnesium is an example of a metal that is more active than hydrogen in the activity series. The reaction between magnesium metal and aqueous hydrochloric acid is an example of a single replacement reaction (a type of redox reaction). The chemical equation for this reaction is shown below: Mg(s) + 2HCl(aq) è MgCl2(aq) + H2(g) Equation 1 When the reaction between the metal and the acid is conducted in a eudiometer, the volume of the hydrogen gas produced can be easily determined. In the experiment described below magnesium metal will be reacted with an excess of hydrochloric acid and the volume of hydrogen gas produced at the experimental conditions will be determined. According to Avogadro’s law, the volume of one mole of any gas at Standard Temperature and Pressure (STP = 273 K and 1 atm) is 22.4 L. Two important Gas Laws are required in order to convert the experimentally determined volume of hydrogen gas to that at STP. 1. Dalton’s law of partial pressures. 2. Combined gas law. Dalton’s Law of Partial Pressures According to Dalton’s law of partial pressures in a mixture of non-reacting gases, the total pressure exerted is equal to the sum of the partial pressures of the individual gases.
    [Show full text]
  • Use of Laboratory Equipement
    USE OF LABORATORY EQUIPEMENT C. Laboratory Thermometers Most thermometers are based upon the principle that liquids expand when heated. Most common thermometers use mercury or colored alcohol as the liquid. These thermometers are constructed as that a uniform-diameter capillary tube surmounts a liquid reservoir. To calibrate a thermometer, one defines two reference points, normally the freezing point of water (0°C, 32°F) and the boiling point of water (100°C, 212°F) at 1 tam of pressure (1 tam = 760 mm Hg). Once these points are marked on the capillary, its length is then subdivided into uniform divisions called degrees. There are 100° between these two points on the Celsius (°C, or centigrade) scale and 180° between those two points on the Fahrenheit (°F) scale. °F = 1.8 °C + 32 The Thermometer and Its Calibration This section describes the proper technique for checking the accuracy of your thermometer. These measurements will show how measured temperatures (read from thermometer) compare with true temperatures (the boiling and freezing points of water). The freezing point of water is 0°C; the boiling point depends upon atmospheric pressure but at sea level it is 100°C. Option 1: Place approximately 50 mL of ice in a 250-mL beaker and cover the ice with distilled water. Allow about 15 min for the mixture to come to equilibrium and then measure and record the temperature of the mixture. Theoretically, this temperature is 0°C. Option 2: Set up a 250-mL beaker on a wire gauze and iron ring. Fill the beaker about half full with distilled water.
    [Show full text]
  • Ear and Forehead Thermometer
    Ear and Forehead Thermometer INSTRUCTION MANUAL Item No. 91807 19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14 Montag, 28. Juli 2014 14:37:38 USAD TABLE OF CONTENTS No. Topic Page 1.0 Definition of symbols 5 2.0 Application and functionality 6 2.1 Intended use 6 2.2 Field of application 7 3.0 Safety instructions 7 3.1 General safety instructions 7 3.3 Environment for which the DSO 364 device is not suited 9 3.4 Usage by children and adolescents 10 3.5 Information on the application of the device 10 4.0 Questions concerning body temperature 13 4.1 What is body temperature? 13 4.2 Advantages of measuring the body tempera- ture in the ear 14 4.3 Information on measuring the body tempera- ture in the ear 15 5.0 Scope of delivery / contents 16 6.0 Designation of device parts 17 7.0 LCD display 18 8.0 Basic functions 19 8.1 Commissioning of the device 19 8.2 Warning indicator if the body temperature is 21 too high 2 19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14 Montag, 28. Juli 2014 14:37:38 TABLE OF CONTENTS USA No. Topic Page 8.3 Backlighting / torch function 21 8.4 Energy saving mode 22 8.5 Setting °Celsius / °Fahrenheit 22 9.0 Display / setting time and date 23 9.1 Display of time and date 23 9.2 Setting time and date 23 10.0 Memory mode 26 11.0 Measuring the temperature in the ear 28 12.0 Measuring the temperature on the forehead 30 13.0 Object temperature measurement 32 14.0 Disposal of the device 33 15.0 Battery change and information concerning batteries 33 16.0 Cleaning and care 36 17.0 “Cleaning” warning indicator 37 18.0 Calibration 38 19.0 Malfunctions 39 20.0 Technical specification 41 21.0 Warranty 44 3 19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14 Montag, 28.
    [Show full text]
  • Infrared Forehead Thermometer (4DET-306) Quick Start Guide
    Infrared Forehead Thermometer (4DET-306) Quick Start Guide To take a forehead temperature: 1” (2-3cm) 1 Press the power button , wait for 2 beeps. 2 Aim the thermometer at the center of the forehead about 1 inch (2-3 cm) from the skin and press the start button S T A R T . 2 START If the body temperature is below 100°F (38.7°C) you will hear one short beep and a 1 happy face will appear on the display. If the body temperature is above 100°F (38.7°C) you will hear one long beep followed by three short beeps and a sad face will appear on the display. Detailed instructions are included in the packaging Temperature Taking Hints and Tips • All body site temperatures are not the same. The • Temporal artery temperature changes faster than a temperature taken at different sites on the body will vary temperature taken rectally, orally or under the arm. A significantly. A forehead (temporal) temperature, for difference of 1°F (.6°C) is normal. Body temperature can example, is usually 0.5°F (0.3°C) to 1.0°F (0.6°C) lower change throughout the day. than an oral temperature. • Consistently low temperature readings may be caused by a • Make certain the thermometer is in FOREHEAD MODE. dirty instrument window. Use an alcohol wipe or a cotton • Non-contact infrared thermometers measure surface swab moistened with alcohol (70% isopropyl) to clean the temperature. Hold the device approximately 1 inch (2-3 instrument window and housing. Gently wipe and let air dry.
    [Show full text]
  • Model 914-604 Infra-Red Thermometer
    Not recommended for use in measuring shiny or polished metal surfaces (stainless steel, aluminum, etc.) The reading will not be accurate. It is not possible to take measurements through transparent materials (glass, Plexiglas, etc.). It will Model 914-604 measure the temperature of the transparent surface Infra-red thermometer instead. It is not possible to measure air temperatures. Measurement errors can occur due to air contaminated with dust, steam, smoke, etc. Battery Replacement: Battery is low and no more measurements are possible. Replace the battery immediately with a CR2032 lithium button cell. 1- Power off the thermometer before replacing the battery A malfunction may occur if the power is on during battery replacement. If a malfunction occurs, restart the device. 2-Twist the battery cover on the back of thermometer to loosen the cover and remove the old battery. A coin will work well. 3- The new CR2032 battery is installed positive side up. Take care that the metal contacts at the top of the battery Congratulations on your purchase of the Infrared compartment are not bent. Thermometer! One-click for a temperature reading. Metal Contacts Metal Contacts No surface contact required, prevents contamination. Take a Measurement: 4-Replace the battery cover and tighten. Place the thermometer close to the item to measure. Click the button once to measure the surface temperature. The Troubleshooting: reading will display for 15 seconds. Problem Solution Hold the button for ongoing readings. No Display: Press the button Auto Shut Off: Ensure battery polarity is correct When the button has not been pressed for 15 seconds, the Change the battery thermometer will automatically shut off to save power.
    [Show full text]
  • ELISA Technical Guide Table of Contents
    ELISA Technical Guide Table of contents Introduction ................................................................................................................3 ELISA technology ......................................................................................................4 ELISA components ....................................................................................................6 ELISA equipment .......................................................................................................7 Equipment maintenance and calibration ..................................................................8 Reagent handling and preparation ...........................................................................9 Test component handling and preparation .............................................................10 Quality control .........................................................................................................11 Sample handling ......................................................................................................12 Pipetting methods ...................................................................................................14 ELISA plate timing ...................................................................................................16 ELISA plate washing ................................................................................................17 Plate reading and data management ......................................................................19 ELISA
    [Show full text]
  • Process Skills Review Warm-Up C
    Process Skills Review Warm-Up C. • Define function • Match the following 1. Puts out fire 2. Curved line of liquid in a graduated cylinder 3. Used to observe insects A. B. Which of the following describes the correct way to handle chemicals in a laboratory? A. It is safe to combine unknown chemicals as long as only small amounts are used. B. Return all chemicals to their original containers. C. Always pour extra amounts of the chemicals called for the experiment. D. To test for odors, always use a wafting motion. Which of the following describes the correct way to handle chemicals in a laboratory? A. It is safe to combine unknown chemicals as long as only small amounts are used. B. Return all chemicals to their original containers. C. Always pour extra amounts of the chemicals called for the experiment. D. To test for odors, always use a wafting motion. What task is being performed in the picture? A. measuring mass with a graduated cylinder B. measuring length with a triple beam balance C. measuring mass with a triple beam balance D. measuring length with a metric ruler What task is being performed in the picture? A. measuring mass with a graduated cylinder B. measuring length with a triple beam balance C. measuring mass with a triple beam balance D. measuring length with a metric ruler John and Lisa are conducting an experiment in their 7th grade science class in which they are handling potentially dangerous chemicals. As John is pouring a chemical from a beaker to a graduated cylinder, he splashes some of the chemical into his eyes.
    [Show full text]
  • WILKES-DISSERTATION-2018.Pdf (4.378Mb)
    Chemostat and Modeling Investigations of Algal Photosynthetic Carbon Isotope Fractionation The Harvard community has made this article openly available. Please share how this access benefits you. Your story matters Citation Wilkes, Elise. 2018. Chemostat and Modeling Investigations of Algal Photosynthetic Carbon Isotope Fractionation. Doctoral dissertation, Harvard University, Graduate School of Arts & Sciences. Citable link http://nrs.harvard.edu/urn-3:HUL.InstRepos:41127152 Terms of Use This article was downloaded from Harvard University’s DASH repository, and is made available under the terms and conditions applicable to Other Posted Material, as set forth at http:// nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of- use#LAA Chemostat and Modeling Investigations of Algal Photosynthetic Carbon Isotope Fractionation A dissertation presented by Elise Wilkes to The Department of Earth and Planetary Sciences In partial fulfillment of the requirements for the degree of Doctor of Philosophy in the subject of Earth and Planetary Sciences Harvard University Cambridge, Massachusetts April, 2018 2018 – Elise Wilkes All rights reserved. Dissertation Adviser: Ann Pearson Elise Wilkes Chemostat and Modeling Investigations of Algal Photosynthetic Carbon Isotope Fractionation Abstract Marine eukaryotic phytoplankton produce organic matter that is depleted in 13C relative to ambient dissolved carbon dioxide. This photosynthetic carbon isotope fractionation (εP) is recorded in marine sediments and used to resolve changes in the global carbon cycle, including variations in atmospheric pCO2. These applications rely upon a coherent understanding of the environmental and physiological controls on P. While classical models for εP are based on the balance between diffusion of CO2 and its fixation into biomass by the enzyme RubisCO, the details of phytoplankton carbon dynamics in reality are more complex.
    [Show full text]
  • 2021 Product Guide
    2021 PRODUCT GUIDE | LIQUID HANDLING | PURIFICATION | EXTRACTION | SERVICES TABLE OF CONTENTS 2 | ABOUT GILSON 56 | FRACTION COLLECTORS 4 | COVID-19 Solutions 56 | Fraction Collector FC 203B 6 | Service Experts Ready to Help 57 | Fraction Collector FC 204 7 | Services & Support 8 | OEM Capabilities 58 | AUTOMATED LIQUID HANDLERS 58 | Liquid Handler Overview/selection Guide 10 | LIQUID HANDLING 59 | GX-271 Liquid Handler 11 | Pipette Selection Guide 12 | Pipette Families 60 | PUMPS 14 | TRACKMAN® Connected 60 | Pumps Overview/Selection Guide 16 | PIPETMAN® M Connected 61 | VERITY® 3011 18 | PIPETMAN® M 62 | Sample Loading System/Selection Guide 20 | PIPETMAN® L 63 | VERITY® 4120 22 | PIPETMAN® G 64 | DETECTORS 24 | PIPETMAN® Classic 26 | PIPETMAN® Fixed Models 66 | PURIFICATION 28 | Pipette Accessories 67 | VERITY® CPC Lab 30 | PIPETMAN® DIAMOND Tips 68 | VERITY® CPC Process 34 | PIPETMAN® EXPERT Tips 70 | LC Purification Systems 36 | MICROMAN® E 71 | Gilson Glider Software 38 | DISTRIMAN® 72 | VERITY® Oligonucleotide Purification System 39 | REPET-TIPS 74 | Accessories Overview/Selection Guide 40 | MACROMAN® 75 | Racks 41 | Serological Pipettes 43 | PLATEMASTER® 76 | GEL PERMEATION 44 | PIPETMAX® CHROMATOGRAPHY (GPC) 76 | GPC Overview/Selection Guide 46 | BENCHTOP INSTRUMENTS 77 | VERITY® GPC Cleanup System 46 | Safe Aspiration Station & Kit 47 | DISPENSMAN® 78 | EXTRACTION 48 | TRACKMAN® 78 | Automated Extraction Overview/ 49 | Digital Dry Bath Series Selection Guide 49 | Roto-Mini Plus 80 | ASPEC® 274 System 50 | Mini Vortex Mixer 81 | ASPEC® PPM 50 | Vortex Mixer 82 | ASPEC® SPE Cartridges 51 | Digital Mini Incubator 84 | Gilson SupaTop™ Syringe Filters 86 | EXTRACTMAN® 52 | CENTRIFUGES 52 | CENTRY™ 103 Minicentrifuge 88 | SOFTWARE 53 | CENTRY™ 117 Microcentrifuge 88 | Software Selection Guide 53 | CENTRY™ 101 Plate Centrifuge 54 | PERISTALTIC PUMP 54 | MINIPULS® 3 Pump & MINIPULS Tubing SHOP ONLINE WWW.GILSON.COM 1 ABOUT US Gilson is a family-owned global manufacturer of sample management and purification solutions for the life sciences industry.
    [Show full text]
  • What's in Your Petri
    Ages: 10-14 Topic: Bacteria, Scientific Method, Classifying, Sampling Time: 2 class days Standards Mission X: Train Like an Astronaut Next Generation Science Standards: 5-LS2-1 Develop a model to describe the movement of matter among plants, animals, decomposers, and the What's in your Petri environment Common Core State Standards: MP.4 Model with BUGS IN SPACE PART 2 mathematics EDUCATOR SECTION (PAGES 1-12) STUDENT SECTION (PAGES 13-21) Background Microbes live everywhere! While many microbes on Earth are harmless, and can even be helpful to humans, some microbes can be unsafe. Microbes belong to a group all by themselves because they are neither plants nor animals. Because they can multiply extremely quickly, it is normal to find millions of them in the same location. Some microbes or “germs”, such as bacteria and mold, can grow on food, dirty clothes, and garbage that people produce. Microbes live on your skin, in your Astronaut Chris Hadfield taking microbe samples on the ISS. mouth, nose, hair, and inside your body. Microbes can also be found aboard the International Space Station (ISS). NASA scientists have reported that some germs on the ISS have different characteristics when grown in space compared to when they grow on Earth. The safety of the crew is of utmost importance. Therefore, cleanliness and proper disposal of garbage is an important part of living on the ISS. Scientists who study microbes are called microbiologists and microbiology is the study of microorganisms or microbes. The root word “micro” comes from Greek and means “small”. These microbes are so small that powerful microscopes are needed to be able to see them.
    [Show full text]
  • THERMOMETERS Refrigerator/Freezer
    THERMOMETERS Refrigerator/Freezer TOP SELLER Traceable® Thermometer/Clock/Humidity Monitor Simultaneously displays time of day, temperature, and humidity ● Features: Min/Max memory, memory clear, °F/°C switchable, 12/24-hour clock ● At the touch of a button, memory recalls the highest and lowest temperature and humidity readings ● Internal sensors make it ideal for use in hoods, storerooms, cleanrooms, incubators, drying chambers and environmental cabinets ● Supplied: stand, wall mount, double-back tape, batteries, Traceable® Certifi cate Cat. No. Range Resolution Accuracy Size/Weight Time: 12/24 hour clock 1 minute 0.01% 4040 Temp: 0.0 to 50.0°C 0.1° ±1°C 4¼ x 2¼ x ½ inch, 2½ ounces Humidity: 20 to 90% RH 1% ±5% RH midrange otherwise ±8% RH Traceable® Big-Digit See-Thru™ Thermometer Jumbo, see-thru display automatically clears and updates MIN/MAX readings daily ● Smart design feature routinely resets MIN/MAX every day ● Perfect for use in fume hoods, refrigerators, plant areas ● Can be easily attached to outside of window to show outdoor temperatures ● Supplied: battery, mounting tape, Velcro® strip, Traceable® Certifi cate Cat. No. Range Resolution Accuracy 4159 –13 to 158°F 0.1° ±1°C 4160 –25 to 70°C 0.1° ±1°C Thermometer with Type-K Probe Specifications Chart Traceable® Length (inch) Certifi cate Display No. of Cat. No. Page No. Supplied Unit Range Supplied Probe Range Resolution Accuracy (°C) Probe Cable Battery Min/Max Probes –40 to 250°C continuous 35 Yes –328 to 2372°F (–200 to 1300°C) 0.1° / 1° ±0.3% + 1°C 0.12 48 1112 yes 1 4003
    [Show full text]
  • 2019 Product Guide About Us Table of Contents
    2019 PRODUCT GUIDE ABOUT US TABLE OF CONTENTS 2 | About Us 40 | Purification 41 | VERITY® Compact CPC System Since 1957, we have proudly offered a wide and reliable range of purification, 4 | Services and Support extraction, and liquid handling solutions to help scientists in their daily work. 42 | Purification with MS 6 | Liquid Handling With our family of products, you’ll find tailored solutions and cost-effective ways to 43 | VERITY® 281 LCMS System manage your liquid samples. The pipetting system is our signature specialty, and we 7T | PIPET E Selection Guide take great joy in sharing our knowledge with pipette users, helping them to achieve 8 | PIPETMAN® M 44 | Extraction their goals. Gilson offers a diverse range of manual to automated liquid handling 10 | PIPETMAN® L 45 | ASPEC® 274 System solutions, including single channel pipettes, multichannel pipettes, semi-automated and automated pipetting solutions, pipette tips, pipette accessories, and tailor-made 12 | PIPETMAN® G 46 | ASPEC® SPE Cartridges services. With our products, you’ll find smart solutions and cost-effective ways to 14 | PIPETMAN® Classic 48 | ASPEC® Positive Pressure Manifold manage your liquid samples, empowering you to successfully complete your research 16 | PIPETMAX® 49 | EXTRACTMAN® and have total confidence in your sample preparation steps. 18 | PLATEMASTER® 50 | Gel Permeation Chromatography (GPC) 19 | Pipette Accessories 51 | VERITY® GPC Cleanup System 20 | PIPETMAN® DIAMOND Tips 24 | MICROMAN® E 52 | Liquid Handlers 26 | REPETMAN® 53 | GX-271 Liquid Handler
    [Show full text]