Microscope-Stage Automatic Thermocontrol System

Microscope-Stage Automatic Thermocontrol System

Microscope-Stage Automatic Thermocontrol System Ensures more accurate and more reliable thermal control of the specimens during the observation under a microscope. Wide product range supports Biotechnology Science and Industry. Thermoplate provides user comfort with High Quality and High Performance. Ensures more accurate and more reliable thermal control of the specimens during the observation under a microscope. Wide product range supports Biotechnology Science and Industry. Microscope-Stage Automatic Thermocontrol System series High Quality & High Performance Stylish & Smart Which is your color ? More accurate, More stable ! Environmentally and user-friendly design Along with its great functionality and high performance, TP’s new design creates a warm, relaxed lab environment. Five color variations are available. Please choose your color! Colorful controller makes lab comfortable! Clear Glass Heater The Thermoplate utilizes a special transparent heating material coated onto a hard glass. The Thermoplate can be used for observing or manipulating specimen under phase contrast and polarization. The flat plate surface ensures easy operation of the microscopes and relocation of specimen. Five colors are available only for standard glass plate and lens heater. Imaging Preset temperature: from room temperature to 50℃ Especially recommended for use when using high-magnification lenses and oil/water immersion lenses ※To prevent heat from escaping to objectives, we recommend use in combination with lens heater. ※For short-term imaging In case of long-term imaging, Stage Top Incubator is recommended. Dimensions of controller (mm) : W98mm × D145mm × H117m Lens Heater 1 INDEX Smart Enables ease of temperature measurement 1 Monitor selector switch Sterilized sensor Heater temperature ⇆ (external) Sterilized sensor can measure OLYMPUS OLYMPUS the actual sample temperature. Sensor temperature Also, it enables on-site calibration Inverted to provide optimal temperature Upright setting at your laboratory. Stereo ※ Significantly enhance Quality Control! Nikon Inverted Nikon Upright Stereo Smart2Temperature Management Software TEM Monitors, records and logs sample or plate temperature which the sensor measures. ZEISS Inverted ZEISS / Leica Saves data in CSV format which can be used in spreadsheets. Upright Stereo ※ Significantly enhance Quality Control! Leica Inverted Upright Stereo KEYENCE KEYENCE Smart Stable imaging, effective for high magnification Inverted 3 / Marzhauser Continuous Current Control All Makers Other Makers In addition to PID control, TP features On-Off Control Ludl Continuous Current Control, minimizing Prior focus drift generated by heat compared to the standard On-Off control method. Especially effective for observation when high magnification is required. Thermoplate provides uniform temperature distribution! An image taken by the thermal camera Cooling and Heating Preset temperature: from 4℃ to 60℃ Handles wide range of observations: yeast, plants, marine life, cell cultures, C.elegans, Planaria etc The application of a thermoelectric cooling device and unique control system produces a compact and highly responsive cooling and heating system. Chiller Unit Temperature Controller 2 OLYMPUS Standard ( Glass plate ・Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0/1.3/1.6mm uniform or 0.5mm at plate center (50x50mm)) Applicable microscopes Applicable microscopes □50 Nikon Inverted IX83/73 Upright Power BX/ BX (U-SVLO/SVRO/SVLB-4/SVRB-4) IX81/71/51 □70 φ110 IX70/50 BH2 IMT2 CX40 cross stage Model Glass thickness CH40/30 round opening: φ110mm TP-110R05 0.5mm TP-110R 1.0mm TP-110R13(with white line) TP-110R13 1.3mm Applicable microscopes ZEISS / Leica IX83/73 □50 155 XY manual stage 130 (IX3-SVR) 189.5 155.5 XY motorized stage (IX3-SSU) 4.5 Model Glass thickness Sub stage TP-IX3-05 0.5mm for opening: 156mm x 190mm Other Makers All Makers ( ) TP-IX3 1.0mm / Applicable microscopes Model Glass thickness □50 CKX41/31 TP-S 1.0mm 127 KEYENCE CK40/30/2 85 XY mechanical stage 8 Model Glass thickness TP-CK05 0.5mm TP-CK 1.0mm 128 142 95 115 □50 5 150 53 14 53 110 4 9 Model Glass thickness Installation Plate TP-CKTS05 0.5mm Fix glass heating plate on the side by TP-CKTS 1.0mm(for well plate use) using attached double sided tape ※For other motorized stages, please refer to P9. Cooling and Heating (Metal plate with a hole・Preset Temperature: 4℃~ 60℃) Applicable microscopes Applicable microscopes IX83/73 Power BX/ BX Inverted IX81/71/51 Upright (U-SVLO/SVRO/SVLB-4/SVRB-4) IX70/50 BH2 IMT2 CX40 cross stage CH40/30 round opening: φ110mm 40 10 40 4 TP-CH110R-C Φ20 Φ110 Φ20 101 101 110 110 Installation Plate Φ20 Fix metal plate on the side Model 9 by magnets TP-CH110R-C Model for 35mm dish and slide glass TP-CH110RBF-C 76 27 TP-CHS-C Φ42 Φ116 TP-CH110RBF-C 3 OLYMPUS Applicable microscopes Applicable microscopes Nikon MVX10 SZX16/SZX10 Stereo SZX16/SZX10 SZX2-ILLT SZX2-ILLB SZX2-ILLK SZX2-ILLD Model Glass thickness Model Glass thickness ZEISS / Leica TP-SZX2A 1.0mm 207 TP-SZX2B 1.0mm 212 152 152 162 162 278 236 7 7 Applicable microscopes Applicable microscopes MVX10 SZX7/SZ61 KEYENCE SZX12/9/7 SZ2-ST + SZ2-ILA SZX-ILLK SZX-ILLB2 / All Makers Other Makers SZX-ILLD2 Model Glass thickness Model Glass thickness TP-SZX 1.0mm TP-SZ2 1.0mm 175 □205 146 □170 230 278 7 10 Applicable microscopes 211 175 Universal 430 75 ~ 100 400 Model Glass thickness TP-UNI 1.6mm 10 Imaging (Metal plate with a hole・ Preset Temperature: room temperature ~ 50℃) Applicable microscopes Applicable microscopes IX83/73 IX83/73 Inverted XY manual stage IX81/71/51 (IX3-SVR) IX70/50 XY motorized stage IMT2 (IX3-SSU) cross stage round opening: φ110mm Sub stage Φ26 (for opening: 156mm x 190mm) 156 Φ26 131 189.5 φ110 155.5 4.5 Model Model TP-110RH26 TP-IX3H26 When using Imaging plate, we recommend to use with Lens heater. ( Please refer to P10.) 4 OLYMUPS Standard ( Glass plate・ Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0/1.6mm uniform or 0.5mm at plate center (50x50mm)) Applicable microscopes Applicable microscopes □50 Nikon Ti Ni Inverted Upright TE2000/300/200 □70 Ci φ108 TMD300/200 90i/80i/55i/50i Rectangular stage E1000/800/600/400/200 round opening: φ108mm Model Glass thickness TP-108R05 0.5mm OPTIPHOT-2 LABOPHOT-2 Applicable microscopes □50 TS100/TS100-F mechanical stage 130 97.5 ZEISS / Leica 5.5 Model Glass thickness TP-TS05 0.5mm Model Glass thickness □50 TP-S 1.0mm Other Makers All Makers / 150 110 9 KEYENCE Model Glass thickness 128 TP-CKTS05 0.5mm 142 95 115 TP-CKTS 1.0mm(for well plate use) 5 Applicable microscopes 53 14 53 TMS/TMS-F □50 4 mechanical stage 130 Installation Plate 90 Fix glass heating plate on the side by using attached double sided tape 5.5 Model Glass thickness TP-TMS05 0.5mm TP-TMS 1.0mm ※For other motorized stages, please refer to P9. Cooling and Heating (Metal plate with a hole・Preset Temperature: 4℃~ 60℃) Applicable microscopes Applicable microscopes Ti Ni Inverted TE2000/300/200 Upright Ci TMD300/200 90i/80i/55i/50i Rectangular stage E1000/800/600/400/200 round opening: φ108mm OPTIPHOT-2 TP-CH108R-C LABOPHOT-2 40 10 40 4 Φ108 Φ20 Φ20 101 110 101 Installation Plate Φ20 110 Model Fix metal plate on the side by magnets TP-CH108RBF-C TP-CHS-C 9 Model TP-CH108R-C 76 27 TP-CH108RBF-C for 35mm dish and slide glass Φ42 Φ116 5 OLYMPUS Nikon Applicable microscopes Stand models: C-DSD 234 Stereo SMZ1500/1000/800 C-DSS C-BD 175 185 254 Model Glass thickness ZEISS / Leica TP-SMZSL 1.0mm 9 Stand models: C-PS 229 169 C-DS 145 198 Model Glass thickness KEYENCE TP-SMZSS 1.0mm 7 / All Makers Other Makers φ180 Model Glass thickness 6.7 TP-SMZR 1.0mm Applicable microscopes 211 175 Universal 430 75 ~ 100 400 Model Glass thickness TP-UNI 1.6mm 10 Imaging (Metal plate with a hole ・Preset Temperature: room temperature ~ 50℃) Applicable microscopes Applicable microscopes Ti Ti Inverted TE2000/300/200 Exclusive XY motorized stage TMD300/200 When installing without Piezo stage, the Rectangular stage stage adapter TID-NA is required. round opening: φ 108mm Φ26 Φ26 129 159.5 φ108 87 109.5 4 Model Model TP-108RH26 TP-TIZH26 When using Imaging plate, we recommend to use with Lens heater. ( Please refer to P10.) 6 Standard ( Glass plate・ Preset Temperature: room temperature ~ 50℃・Glass plate thickness: 1.0/1.6mm uniform or 0.5mm at plate center (50x50mm)) Applicable microscopes Applicable microscopes 86 Inverted Axio Observer Upright □ Axio Examiner Axiovert 50 130 Axio Imager (K type frame holder) 160 110 Axiophot2 Axioplan2 Model Glass thickness Axioskop TP-SQ05 0.5mm Axiolab OLYMPUS TP-SQ 1.0mm Axiolab Pol Axiolab Imager □ 50 135 160 89 110 3 Nikon Model Glass thickness TP-SQ05FT 0.5mm(flat type) Model Glass thickness TP-S 1.0mm Applicable microscopes □ Axio Observer 50 130 Axiovert 165 128 86 142 95 105 (M type frame holder) 115 3 Model Glass thickness 5 ZEISS / Leica 53 14 53 TP-SQM05 0.5mm TP-SQM 1.0mm 4 Installation Plate Fix glass heating plate on the side by using attached double sided tape Other Makers All Makers / KEYENCE Cooling and Heating (Metal plate with a hole・ Preset Temperature: 4℃~ 60℃) Applicable microscopes Applicable microscopes Axio Observer Axio Observer Inverted Axiovert Axiovert (K type frame holder) (M type frame holder) φ2 0 φ2 0 83 160 165 30 φ68 Φ6 8 100 110 12 4.5 Model Model TP-CHSQ-C TP-CHSQM -C models for Leica microscopes are exclusively distributed through Leica worldwide network the name of ''Leica MATS'' 7 Applicable microscopes Stereo Axio Discovery Stemi2000 (with large base stand N: 495052 9801)

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    12 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us