Laboratory Equipment Functions

Total Page:16

File Type:pdf, Size:1020Kb

Laboratory Equipment Functions Laboratory Equipment Functions 1. Balance (electronic or triple beam) Used for determining mass in grams 2. Beaker Glass laboratory “cup”, not accurate for measurement 3. Beaker tongs Used to handle hot beakers 4. Pipet Used to transfer liquids 5. Buret Used to accurately dispense small amounts of solutions; most accurate 6. Buret clamp Used to secure the buret on the ring stand 7. Bunsen burner Used for heating chemicals 8. Clay triangle Used to support a crucible or evaporating dish 9. Crucible Used to heat chemicals to a very high temperature 10. Crucible tongs Used to handle hot crucibles & evaporating dishes 11. Graduated cylinder Used to measure accurate volumes in milliliters (mL) 12. Erlenmeyer flask Used to mix chemicals in solutions 13. Evaporating dish Used to evaporate small amounts of liquids 14. Forceps Used to handle or transfer solid samples 15. Funnel Used to transfer or filter liquids 16. Safety goggles Used to protect your eyes 17. Iron ring (ring clamp) Used to support wire gauze or clay triangle on ring stand 18. Mortar and pestle Used to grind chemicals into powder 19. Ring stand Used to support the iron ring or any clamp 20. Scoopula Used to transfer small amounts of a solid 21. Glass stirring rod Used to mix or dissolve chemicals 22. Test tube Used for heating and observing chemical reactions 23. Test tube brush Used to clean test tubes 24. Test tube tongs Used to handle hot test tubes 25. Test tube rack Used to hold and store test tubes 26. Test tube clamp Holds test tube in place on ring stand for heating 27. Volumetric flask Used for making solutions of a specific concentration 28. Wash bottle Used to rinse glassware 29. Watch glass Used to cover an evaporating dish or beaker to avoid splattering 30. Well plate Used for small scale reactions 31. Wire gauze Used as a support and for efficient heating 32. Hot plate Used for heating chemicals which may be flammable 33. Thermometer Used to measure temperature .
Recommended publications
  • AOAC Official Method 2011.25 Insoluble, Soluble, and Total Dietary Fiber in Foods
    AOAC Official Method 2011.25 supplies/fisherbrand.html) or 250 mL polypropylene bottles with Insoluble, Soluble, and Total Dietary Fiber in Foods polypropylene caps. Enzymatic-Gravimetric-Liquid Chromatography (c) Fritted crucible.—Gooch, fritted disk, Pyrex® 50 mL, First Action 2011 pore size, coarse, ASTM 40–60 µm (Corning No. 32940-50C® [Applicable to plant material, foods, and food ingredients or equivalent; http://www.labplanet.com/corning-crucible-gooch- consistent with CODEX Alimentarius Commission high-c-50-ml-32940-50c.html). Prepare four for each sample as Definition adopted in 2009 and modified slightly in 2010 follows: Ash overnight at 525°C in muffle furnace. Cool furnace to (ALINORM 09/32/REP and ALINORM 10/33/REP, respectively), 130°C before removing crucibles to minimize breakage. Remove including naturally occurring, isolated, modified, and synthetic any residual Celite and ash material by using a vacuum. Soak in 2% polymers meeting that definition.] cleaning solution, C(i), at room temperature for 1 h. Rinse crucibles See Tables 2011.25A–H for the results of the interlaboratory with water and deionized water. For final rinse, use 15 mL acetone study supporting acceptance of the method. and air dry. Add approximately 1.0 g Celite to dried crucibles and A. Principle dry at 130°C to constant weight. Cool crucible in desiccators for approximately 1 h and record mass of crucible containing Celite. A method is described for the measurement of insoluble, (d) Filtering flask.—Heavy-walled, 1 L with side arm. soluble, and total dietary fiber (IDF, SDF, and TDF, respectively), (e) Rubber ring adaptors.—For use to join crucibles with inclusive of the resistant starch (RS) and the water:alcohol soluble filtering flasks.
    [Show full text]
  • VACUUM RECOVERY of ASPHALT EMULSION RESIDUE (An Arizona Method)
    ARIZ 504 July 1980 (3 Pages) VACUUM RECOVERY OF ASPHALT EMULSION RESIDUE (An Arizona Method) Scope (d) No. 10 sieve conforming to AASHTO designation M 92. I. This method describes a low temperature vacuum procedure for recovery of the asphalt residue (e) Vacuum recovery apparatus as shown from asphalt emulsions. It is is not suitable for assembled in Fig. I. quantitative recovery of solvents from emulsions I) Vacuum source capable of producing an containing low boiling range distillates. absolute vacuum within the system of approximately 710 mm (28 in.) mercury. Apparatus 2) Thermometer - shall have a range of _5° to 1. The apparatus shall consist of the following: +200°C (23°F to 392°F). The overall length (a) Brass stirring rod. shall be 600 mm (24 in.) and the distance from the bottom of the bulb to the zero point (b) 8 oz. ointment can. shall be 300 mm (12 in.) (c) 100 ml. stainless steel beaker. 3) Stirrer hot plate. VACUUM RECOVERY APPARATUS 300 mm Allihn condenser H20 Out / Thermometer Vacuum Release Pinch Clamp 500 m. 1,000 ml. Filtration Flask Filtration Flask Teflon Stirring Bar H20 In 500 ml. Filtration Flask Portable Heat Gun FIGURE I ARIZ 504 July 1980 4) Teflon covered stirring bar. (g) Insert the stoppered themometer (positioned 5) 1000 ml. and two 500 ml. filtering flasks with in the stopper at an angle to prevent contact with tubulation. stirring bar) into the flask and set on hot plate at a medium high heat setting (#4). The bulb of the 6) 300 mm Allihn condensor.
    [Show full text]
  • LAB: One Tube Reaction Part 1
    AP Chemistry LAB: One Tube Reaction Part 1 Objective: To monitor and document the chemical changes occurring in a single test tube containing a predetermined mixture of chemicals. Materials: test tube, iron nail, sodium chloride, copper (II) sulfate, distilled water, glass stirring rod, tissue paper, parafilm wax Procedures: 1. Label a test tube to identify your group 2. Fill approx. 1/3 of the test tube with copper (II) sulfate crystals. Gently tap the tube to allow the crystals to settle. 3. Using a glass stirring rod, carefully cover the crystals with a layer of Kimwipe tissue paper. 4. Slowly, and with as little disturbance as possible, add enough distilled water to just cover the paper and blue crystals. 5. Repeat the process for the sodium chloride, filling approx. 1/3 of the test tube. Gently tap the tube to allow the crystals to settle. 6. Push more tissue paper into the test tube on top of the white crystals. 7. Add enough water to cover the tissue paper and white crystals. 8. Obtain an iron nail and expose the surface by rubbing with sand paper. 9. Carefully slide the nail into the test tube. 10. Continue adding water until the nail is completely covered. 11. Cover the test tube with parafilm wax and record your Day 1 observations. 12. Return the test tube to the test tube rack. 13. Continue to monitor and record your observations for the next several days, as indicated in the data table. Data: 1. Complete the NFPA label for the two chemicals used in this lab.
    [Show full text]
  • Determination of the Identity of an Unknown Liquid Group # My Name the Date My Period Partner #1 Name Partner #2 Name
    Determination of the Identity of an unknown liquid Group # My Name The date My period Partner #1 name Partner #2 name Purpose: The purpose of this lab is to determine the identity of an unknown liquid by measuring its density, melting point, boiling point, and solubility in both water and alcohol, and then comparing the results to the values for known substances. Procedure: 1) Density determination Obtain a 10mL sample of the unknown liquid using a graduated cylinder Determine the mass of the 10mL sample Save the sample for further use 2) Melting point determination Set up an ice bath using a 600mL beaker Obtain a ~5mL sample of the unknown liquid in a clean dry test tube Place a thermometer in the test tube with the sample Place the test tube in the ice water bath Watch for signs of crystallization, noting the temperature of the sample when it occurs Save the sample for further use 3) Boiling point determination Set up a hot water bath using a 250mL beaker Begin heating the water in the beaker Obtain a ~10mL sample of the unknown in a clean, dry test tube Add a boiling stone to the test tube with the unknown Open the computer interface software, using a graph and digit display Place the temperature sensor in the test tube so it is in the unknown liquid Record the temperature of the sample in the test tube using the computer interface Watch for signs of boiling, noting the temperature of the unknown Dispose of the sample in the assigned waste container 4) Solubility determination Obtain two small (~1mL) samples of the unknown in two small test tubes Add an equal amount of deionized into one of the samples Add an equal amount of ethanol into the other Mix both samples thoroughly Compare the samples for solubility Dispose of the samples in the assigned waste container Observations: The unknown is a clear, colorless liquid.
    [Show full text]
  • Funnels and Filters
    51 FUNNELS AND FILTERS Buchner Funnels 260MM (10.25") INSIDE DIAMETER, 203MM (8") OVERALL HEIGHT, 127MM (5") RIM TO PLATE CATALOG NO. DESCRIPTION PRICE/EACH H14620-0000 Funnel with Coarse Porosity Fixed Plate $216.00 H14620-1260 Funnel with Coarse Porosity Removable Plate 216.00 H14625-3510 Funnel with Medium Porosity Fixed Plate 216.00 H14626-3510 Funnel with Medium Porosity Removable Plate 216.00 H14627-0000 Funnel with Perforated Fixed Plate 216.00 Table-Top H14627-1260 Funnel with Perforated Removable Plate 216.00 Buchner 457MM (18") INSIDE DIAMETER, 292MM (11.5") OVERALL HEIGHT, 203MM (8") RIM TO PLATE Funnels CATALOG NO. DESCRIPTION PRICE/EACH With Fritware® Porous H14621-0000 Funnel with Coarse Porosity Fixed Plate $540.00 Filter or HDPE H14621-1457 Funnel with Coarse Porosity Removable Plate 540.00 H14625-3518 Funnel with Medium Porosity Fixed Plate 540.00 Perforated Plate H14626-3518 Funnel with Medium Porosity Removable Plate 540.00 Polyethylene funnels are H14628-0000 Funnel with Perforated Fixed Plate 465.00 one piece design with a H14627-1457 Funnel with Perforated Removable Plate 465.00 FIXED or REMOVABLE Custom sizes available upon request. 610MM (24") INSIDE DIAMETER, 330MM (13") OVERALL HEIGHT, 267MM (10.25") RIM TO PLATE porous filter plate CATALOG NO. DESCRIPTION PRICE/EACH supported by a multiple ring grid. Filter plates are made of high density H14622-0000 Funnel with Coarse Porosity Fixed Plate $1125.00 1 polyethylene 6.4mm ( ⁄4") thick with a non-porous ring at the periphery of the plate H14622-1610 Funnel with Coarse Porosity Removable Plate 1125.00 1 H14625-3524 Funnel with Medium Porosity Fixed Plate 1125.00 which seals filter paper when used.
    [Show full text]
  • Equipment Detailsr07
    Lab Equipment Details Lab Equipment Glass Flasks 150ml 250ml 500ml Lab Equipment Glass Beakers 150ml 250ml 500ml Lab Equipment Glassware But once removed, only the cap stays highlighted. Droppers critical to Lab An activated Dropper coursework can be found highlights the entire bottle. already in the workspace. Dropper Dropper Dropper Activated In Use Lab Equipment Gastight Syringe Small A pre-filled gastight syringe can be used with a NMR tube to safely fill through the top in preparation for use with the NMR spectrometer. Gastight Syringe NMR Tube with Holder with Holder Lab Equipment NMR Tube Spinner An NMR Tube filled with gas for use with the NMR Spectrometer Simply use the NMR Tube with needs to be inserted into the the Tube Spinner. Spinner before it can be used. NMR Tube NMR Tube Spinner NMR Tube Spinner with Holder with NMR Tube inserted Once the Tube slotted into the holder is inserted into the top part of the spectrometer, users can type in a number for Lab Equipment the frequency they’d like to scan. NMR Spectrometer XL The NMR Tube holder can then be slotted into the highlighted tube on the NMR Spectrometer. NMR Tube filled with appropriate substance is slotted (used with) in the holder. Lift will perpare the Spectrometer for the tube holder insertion. Scan No. Allows the user to change the frequency at which the tube is scanned The NMR Tube holder can then be slotted into the top tube on Lab Equipment the NMR Spectrometer. NMR Spectrometer XL NMR Tube filled with appropriate substance is slotted (used with) in the holder.
    [Show full text]
  • METHODS & STANDARD OPERATING PROCEDURES (Sops)
    METHODS & STANDARD OPERATING PROCEDURES (SOPs) OF EMISSION TESTING IN HAZARDOUS WASTE INCINERATOR FOREWARD COVR PAGE TEAM CHAPTER TITLE PAGE NO Chapter - 1 Stack Monitoring – Material And Methodology For Isokinetic Sampling 1-28 Chapter - 2 Standard Operating Procedure (SOP) For Particulate Matter Determination 29-38 Chapter - 3 Determination Of Hydrogen Halides (Hx) And Halogens From Source Emission 39-54 Chapter - 4 Standard Operating Procedure For The Sampling Of Hydrogen Halides And Halogens From Source Emission 55-61 Determination Of Metals And Non Metals Emissions From Chapter - 5 Stationarysources 62-79 Standard Operating Procedure (Sop) For Sampling Of Metals And Non Chapter - 6 Metals & 80-97 Standard Operating Procedure (Sop) Of Sample Preparation For Analysis Of Metals And Non Metals Chapter - 7 Determination Of Polychlorinated Dibenzo-P-Dioxins And 98-127 Polychlorinated Dibenzofurans Standard Operating Procedure For Sampling Of Polychlorinated Chapter - 8 Dibenzo-P-Dioxins And Polychlorinated Dibenzofurans & 128-156 Standard Operating Procedure For Analysis Of Polychlorinated Dibenzo- P-Dioxins And Polychlorinated Dibenzofurans Project Team 1. Dr. B. Sengupta, Member Secretary - Overall supervision 2. Dr. S.D. Makhijani, Director - Report Editing 3. Sh. N.K. Verma, Ex Additional Director - Project co-ordination 4. Sh. P.M. Ansari, Additional Director - Report Finalisation 5. Dr. D.D. Basu, Senior Scientist - Guidance and supervision 6. Sh. Paritosh Kumar, Sr. Env. Engineer - Report processing 7. Sh. Dinabandhu Gouda, Env. Engineer - Data compilation, analysis and preparation of final report 8. Sh. G. Thirumurthy, AEE - - do - 9. Sh. Abhijit Pathak, SSA - - do - 10. Ms. Trapti Dubey, Jr. Professional (Scientist) - - do - 11. Er. Purushotham, Jr. Professional (Engineer) - - do - 12.
    [Show full text]
  • ARC Laboratory Manual for Architectural Conservators
    A LABORATORY MANUAL FOR ARCHITECTURAL CONSERVATORS Jeanne Marie Teutonico ICCROM Rome 1988 CONTENTS Foreword v Preface vii General Principles: Laboratory Science 1. Sampling 3 2. Measurement and Error: Precision, Accuracy, Statistics 7 3. Measurement: Mass (Use of the Balance) 11 4. Measurement: Length (Use of the Vernier Caliper and Micrometer) 16 5. Measurement: Volume 21 6. Measurement: Solutions 26 7. Measurement: pH 30 Porous Building Materials 8. Water Absorption by Total Immersion 35 9. Water Drop Absorption 41 10. Penetration of Water: Capillary Action 43 11. Porosity of Granular Beds 45 12. Porosity in Solids: Indirect Measurement by Water Absorption 50 13. Porosity in Solids: Hydrostatic Weighing 52 14. Movement of Salts 56 15. Salt Crystallization 57 16. Qualitative Analysis of Water-soluble Salts and This publication was printed with a generous Carbonates 58 contribution from the government of 17. Semiquantititive Analysis of Water-soluble Salts 68 Finland. Earthen Building Materials 18A. Particle Size Analysis: Part I Sieving Procedure 73 ISBN 92-9077-083-X Via di San Michele 13 00153 Rome RM, Italy Printed in Italy III Earthen Building Materials (continued) FOREWORD 18B. Particle Size Analysis: Part II Sedimentation Procedure: Hydrometer Method 83 19. Plastic Limit of Soils 96 After his appointment as director of ICCROM in 1977, Sir Bernard FEILDEN proposed to emphasize the interdisciplinary 20. Liquid Limit of Soils 102 character of conservation by introducing scientists to field work and architects to laboratories. Consequently it was decided to introduce a series of laboratory exercises Stone. Brick and Mortars designed for the needs of architectural conservators and conservation architects in the program of the International 21.
    [Show full text]
  • General Chemistry Laboratory I Manual
    GENERAL CHEMISTRY LABORATORY I MANUAL Fall Semester Contents Laboratory Equipments .............................................................................................................................. i Experiment 1 Measurements and Density .............................................................................................. 10 Experiment 2 The Stoichiometry of a Reaction ..................................................................................... 31 Experiment 3 Titration of Acids and Bases ............................................................................................ 10 Experiment 4 Oxidation – Reduction Titration ..................................................................................... 49 Experiment 5 Quantitative Analysis Based on Gas Properties ............................................................ 57 Experiment 6 Thermochemistry: The Heat of Reaction ....................................................................... 67 Experiment 7 Group I: The Soluble Group ........................................................................................... 79 Experiment 8 Gravimetric Analysis ........................................................................................................ 84 Scores of the General Chemistry Laboratory I Experiments ............................................................... 93 LABORATORY EQUIPMENTS BEAKER (BEHER) Beakers are containers which can be used for carrying out reactions, heating solutions, and for water baths. They are for
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • Catching up with Runaway Hot Plates
    Catching up with Runaway Hot Plates Kimberly Brown1, Mark Mathews2, Joseph Pickel3 1‐ Office of Environmental Health and Radiation Safety University of Pennsylvania, Philadelphia, PA 2‐ Environmental Safety and Health Directorate, Oak Ridge National Laboratory, Oak Ridge TN 3‐ Physical Sciences Directorate, Oak Ridge National Laboratory, Oak Ridge TN Recent Events with Malfunctioning Abstract Cause of Fire identified as Runaway Hot Plates Hotplate Several research institutions report safety events involving hotplates that have been In recent years, there have been numerous reports of runaway hot plates — hot left on and unattended or that have heated uncontrollably, sometimes resulting in plates that heat uncontrolled despite the setting or the fact that the controls are in significant damage in the process. Some of the known events are listed below: the off position. Some of these events have resulted in damage to research • June 29, 2005: Lawrence Berkeley National Laboratory — A laboratory hot plate’s facilities. The Division of Chemical Health and Safety has investigated this issue power switch failed, resulting in a fire in the fume hood. Although the switch using all available information and soliciting additional information viaasurvey position, switch detent, and indicator light demonstrated that the power was off, conducted in April 2017 to determine the cause of these issues and to develop Valid NRTL listing electrical power continued to flow to the heating elements. strategies to prevent future “runaways‘’. Results of this survey and best practices (http://www2.lbl.gov/ehs/Lessons/pdf/FinalHotPlateLL.pdf) are described herein. • April 2007: University of California — Following a March 2007 report of a malfunctioning hot plate that heats while in the ‘off’ position, UC EHS personnel send out a system wide message concerning the issue citing “several explosions or Survey Information fire events involving defective hot plates that resulted in injuries to laboratory employees or damage to laboratories” over the previous five years.
    [Show full text]
  • Portable Fluid Analysis Kit Manual
    Donaldson Delivers Portable Fluid Analysis Kit Patch Test Kit Manual Kit Part Number X009329 Carrying Case Membrane Holder & Funnel Assembly P567863 Filter for Solvent Dispensing Bottle P567860 (Qty. 3) 500 ml Solvent Sampling Dispensing Bottle Pump P176431 Microscope 120 ml P567864 Sample Bottles (Qty. 6) Plastic Tubing P567861 (5 ft.) 1.2 micron Patch Covers Membrane P567912 (Qty. 150) Filters P567869 Zip Drive of (Qty. 100) Reference Information Membrane Filter Forceps Sharpie Analysis Cards (3”x5”) P567865 (Qty. 50) 5 micron Membrane Filters Marker P567868 (Qty. 50) Case Size: Height: 14.5”/368.3mm | Width: 19.25”/489mm | Depth: 7.75”/197mm | Case Weight: 9.95 lbs./4.51 kg 1 2 3 Assemble waste bottle, funnel- Install solvent* dispensing tube and Rinse the funnel-patch assembly patch assembly, and vacuum pump install solvent filter on end of the with the filtered solvent to remove to form the sample processing dispensing tube. background contamination. The assembly. Tighten the vacuum patch should not be in place for pump o-ring on the funnel-patch * Mineral spirits are the most this process. assembly tube by turning the commonly used solvent aluminum locking device. 2 • www.donaldson.com Patch Test Kit Manual 4 5 6 Separate the funnel from the patch Reattach the funnel to the filter Agitate the sample fluid bottle and supporter and install a filter patch patch base with filter patch. Twist pour 25ml into the funnel. 25ml with ink grid up. (If the patch has an lock the funnel to the base. is denoted by the first line on the ink grid) funnel (closest to the patch).
    [Show full text]