Monocular Microsaccades Are Visual-Task Related

Total Page:16

File Type:pdf, Size:1020Kb

Monocular Microsaccades Are Visual-Task Related Journal of Vision (2016) 16(3):37, 1–16 1 Monocular microsaccades are visual-task related Anglia Vision Research, Department of Vision and Hearing Sciences, Anglia Ruskin University, Cambridge, UK Davalor Research Center, # Josselin Gautier Universitat Politecnica` de Catalunya, Barcelona, Spain $ College of Optometry, University of Houston, Harold E. Bedell Houston, TX, USA $ Anglia Vision Research, Department of Vision and Hearing Sciences, John Siderov Anglia Ruskin University, Cambridge, UK $ Anglia Vision Research, Department of Vision and Hearing Sciences, Sarah J. Waugh Anglia Ruskin University, Cambridge, UK $ During visual fixation, we constantly move our eyes. These microscopic eye movements are composed of Introduction tremor, drift, and microsaccades. Early studies concluded that microsaccades, like larger saccades, are binocular The occurrence of microsaccades during fixation has and conjugate, as expected from Hering’s law of equal been reported since 1907 (Dodge, 1907). Thereafter, innervation. Here, we document the existence of multiple studies using different recording techniques monocular microsaccades during both fixation and a concluded that microsaccades are binocular coordi- discrimination task, reporting the location of the gap in a foveal, low-contrast letter C. Monocular microsaccades nated movements with similar timing, directions (con- differ in frequency, amplitude, and peak velocity from jugacy), and velocities in the two eyes (Ditchburn & binocular microsaccades. Our analyses show that these Ginsborg, 1953; Krauskopf, Cornsweet, & Riggs, 1960; differences are robust to different velocity and duration Schulz, 1984; St. Cyr & Fender, 1969; Yarbus, 1967). criteria that have been used previously to identify Zuber, Stark, and Cook (1965) demonstrated that microsaccades. Also, the frequency of monocular saccades, microsaccades, and corrective saccades (see microsaccades differs systematically according to the next paragraph) lie on a single linear peak velocity task: monocular microsaccades occur more frequently versus amplitude relationship, the so-called main during fixation than discrimination, the opposite of their sequence, and deduced that these movements result binocular equivalents. However, during discrimination, from a common physiological mechanism. Boyce monocular microsaccades occur more often around the (1967) observed that the amplitude distribution of discrimination threshold, particularly for each subject’s microsaccades during monocular fixation exhibits a dominant eye and in case of successful discrimination. cut-off around 120 with a few outliers around 200.A We suggest that monocular microsaccades play a functional role in the production of fine corrections of review of the fixation data from 14 experiments by eye position and vergence during demanding visual Ditchburn and Foley-Fisher (1967) confirmed these tasks. results and indicated a median microsaccadic ampli- tude during fixation of 40–50. More recent studies reported a larger mean microsaccade size, between 13.70 and 38.40 (see the review by Martinez-Conde, Macknik, Troncoso, & Hubel, 2009). The disagreement about the amplitude characteristics of microsaccades Citation: Gautier, J., Bedell, H. E., Siderov, J., & Waugh, S. J. (2016). Monocular microsaccades are visual-task related. Journal of Vision, 16(3):37, 1–16, doi:10.1167/16.3.37. doi: 10.1167/16.3.37 Received July 2, 2015; published February 24, 2016 ISSN 1534-7362 Downloaded from jov.arvojournals.org on 09/28/2021This work is licensed under a Creative Commons Attribution 4.0 International License. Journal of Vision (2016) 16(3):37, 1–16 Gautier, Bedell, Siderov, & Waugh 2 (Collewijn & Kowler, 2008) might be traced in part to In the recent booming literature about fixational different levels of subject expertise (Cherici, Kuang, eye movements, there is common agreement to base Poletti, & Rucci, 2012; Martinez-Conde et al., 2009) the detection of microsaccades on three criteria: their and recording conditions, considering that recordings peak velocity, a minimum duration, and temporal were mainly made with experienced subjects using the coordination between the two eyes (Engbert & Kliegl, optical lever technique in the 1950s and 1960s, whereas 2003b). First, the peak eye-movement velocity should recent studies of fixation used video-based eye tracking exceed a velocity threshold gx,y calculated typically as systems on na¨ıve participants. Cherici et al. (2012) also 4 to 6 standard deviations above the median eye emphasize that previous studies typically assumed that velocity (see equations 2 and 3 in Engbert & the distribution of gaze positions during fixation is Mergenthaler, 2006). Second, the movement must normal, an assumption that does not hold. It is also exceed a minimal duration to ensure that very brief acknowledged that although the distinction between high-velocity events, such as dynamic overshoots or microsaccades and saccades based on their size (,18)is instances of velocity noise, are not identified as a arbitrary, this distinction is practical in that it captures separate microsaccade. Although the minimum dura- approximately 90% of the nonvoluntary fixational tion is not always mentioned and is sampling- saccades (Martinez-Conde et al., 2009). frequency dependent, a representative range of values In contrast to the classical viewpoint that fixation is 6–12 ms (Engbert & Kliegl, 2003b, 2004; Engbert & saccades are binocular and conjugate, Engbert & Kliegl Mergenthaler, 2006). Finally, a criterion of a temporal (2003a) identified a significant number of monocular overlap of microsaccades made by both eyes has been microsaccades during fixation, which were reported used to ‘‘reduce noise in the detection procedure’’ subsequently to be inefficient in counteracting visual according to Engbert and Kliegl (2003b, p. 1037). fading (Martinez-Conde, Macknik, Troncoso, & Dyar, Thus, in the literature spanning the last decade, 2006). Several investigators reported that binocular monocular microsaccades detected in only one eye microsaccades occur mainly in the horizontal direction, that could have been detected through binocular while monocular microsaccades occur in both the recordings were indeed excluded (Engbert & Kliegl, horizontal and vertical directions (Engbert & Kliegl, 2003b; Martinez-Conde et al., 2009). 2003a; Hermens & Walker, 2010; Kloke, Jaschinski, & Jainta, 2009). Disconjugate microsaccades have also been observed and measured neurophysiologically in Methods monkeys (Horn & Cullen, 2012), in whom a significant proportion (approx. 10%) could potentially be mon- ocular microsaccades (see their figure 1F). Despite the Observers suggestions that monocular microsaccades might have a different origin and should be analyzed separately Ten subjects (five men, five women; age range 21–35 from their binocular counterparts (Hermens & Walker, years) with normal or corrected-to-normal visual acuity 2010), the conditions that favor monocular micro- participated in the study. The data for two subjects saccades, their kinematic properties, and their potential were discarded due to spurious signals, probably from role in vision has not been explored. In this work, we unavoidable reflections from their spectacles. With the aim to assess the occurrence and characteristics of exception of author JG, the subjects were na¨ıve about monocular microsaccades during two visual tasks the purpose of the experiments. Procedures were involving either involuntary alone, or both involuntary approved by the ethics board of the Anglia Ruskin and voluntary fixational eye movements, and examine University, Cambridge, UK, in accordance with the how monocular microsaccades differ from their previ- Code of Ethics of the World Medical Association ously reported binocular counterparts. (Declaration of Helsinki) and written informed consent Small monocular corrective movements that occur was obtained from all observers. following saccades, presumably because of neurological control signal reversals (Bahill, Clark, & Stark, 1975) and especially microsaccades, were reported in the Apparatus literature as dynamic overshoots (Abadi, Scallan, & Clement, 2000; Kapoula, Robinson, & Hain, 1986) and Stimuli were generated in Matlab (MathWorks, ringing (Kimmel, Mammo, & Newsome, 2012). Unlike Natick, MA), using Psychophysics Toolbox extension dynamic overshoots, the monocular saccades we and displayed on a 21 in. CRT screen (NEC Multisync observe do not follow immediately after microsaccades, 2141SB) with spatial resolution of 1600 3 1200 pixels, a even if—as we will suggest—they also may play a refresh rate of 85 Hz, and a background luminance of corrective role. 100 cd/m2. The stimuli were displayed at a viewing Downloaded from jov.arvojournals.org on 09/28/2021 Journal of Vision (2016) 16(3):37, 1–16 Gautier, Bedell, Siderov, & Waugh 3 Figure 1. Discrimination versus fixation conditions. (A) Illustration of the stimuli for discrimination (left) and fixation (right). (B) In both conditions, the stimuli were alternated with a blank screen that was displayed until the subject pressed a response button that initiated the next trial. As shown here, the orientation and contrast of the discrimination stimulus varied randomly from trial to trial. (C) The main sequence diagram pooled for eight subjects for monocular (left eye only; shown in blue for clarity) and binocular microsaccades (red) during the discrimination task. (D) A zoomed-in view of the lower left section (box in panel C) of the main sequence plot. (E)
Recommended publications
  • Management of Microtropia
    Br J Ophthalmol: first published as 10.1136/bjo.58.3.281 on 1 March 1974. Downloaded from Brit. J. Ophthal. (I974) 58, 28 I Management of microtropia J. LANG Zirich, Switzerland Microtropia or microstrabismus may be briefly described as a manifest strabismus of less than 50 with harmonious anomalous correspondence. Three forms can be distinguished: primary constant, primary decompensating, and secondary. There are three situations in which the ophthalmologist may be confronted with micro- tropia: (i) Amblyopia without strabismus; (2) Hereditary and familial strabismus; (3) Residual strabismus after surgery. This may be called secondary microtropia, for everyone will admit that in most cases of convergent strabismus perfect parallelism and bifoveal fixation are not achieved even after expert treatment. Microtropia and similar conditions were not mentioned by such well-known early copyright. practitioners as Javal, Worth, Duane, and Bielschowsky. The views of Maddox (i898), that very small angles were extremely rare, and that the natural tendency to fusion was much too strong to allow small angles to exist, appear to be typical. The first to mention small residual angles was Pugh (I936), who wrote: "A patient with monocular squint who has been trained to have equal vision in each eye and full stereoscopic vision with good amplitude of fusion may in 3 months relapse into a slight deviation http://bjo.bmj.com/ in the weaker eye and the vision retrogresses". Similar observations of small residual angles have been made by Swan, Kirschberg, Jampolsky, Gittoes-Davis, Cashell, Lyle, Broadman, and Gortz. There has been much discussion in both the British Orthoptic Journal and the American Orthoptic journal on the cause of this condition and ways of avoiding it.
    [Show full text]
  • Routine Eye Examination
    CET Continuing education Routine eye examination Part 3 – Binocular assessment In the third part of our series on the eye examination, Andrew Franklin and Bill Harvey look at the assessment and interpretation of binocular status. Module C8290, one general CET point, suitable for optometrists and DOs he assessment of binocular previous question. Leading questions function is often one of the should be avoided, especially when weaker areas of a routine, dealing with children. If they are out if observation of candidates of line ask the patient ‘Which one is out in the professional qualifica- of line with the X?’ Ttions examination is any guide. Tests are You should know before you start the done for no clearly logical reason, often test which line is seen by which eye. because they always have been, and in If you cannot remember it from last an order which defeats the object of the time, simply look at the target through testing. Binocular vision seems to be one the visor yourself (Figure 1). Even if of those areas that practitioners shy away you think you can remember, check from, and students often take an instant anyway, as it is possible for the polarisa- dislike to. Many retests and subsequent tion of the visor not to match that of the remakes of spectacles are the result of a Mallett Unit at distance or near or both, practitioner overlooking the effects of a Figure 1 A distance fixation disparity target especially if the visor is a replacement. change of prescription on the binocular If both eyes can see both bars, nobody status of the patient.
    [Show full text]
  • The Effect of the Fixation Disparity on Photogrammetric Processes
    The Effect of the Fixation Disparity on Photogrammetric Processes SANDOR A. VERES, Asst. Proj., Surveying and Mapping, Purdue University ABSTRACT: This paper reviews the function oj the human eyes in photogram­ metry, and discusses its limitations. The correction of the observation error is presented by mathematical derivations and practical examples. The paper points out the need for continued development of techniques in view of con­ stantly increasing requirements. INTRODUCTION study of coincidence is most important from the photogrammetric point of view. For a HOTOGRAMMETRIC instrumentation has undergone a revolutionary development study of this kind an instrument called a P horopter has been used. since the second World War. A precision photogrammetric instrument today is able to The horopter designed by Tschermak con­ provide measurement to within a precision of sists of thirteen steel channels mounted so as ± 3 microns. By using these precision in­ to converge to the midpoint of the inter­ struments the compensation of errors in­ pupillary base line of the two eyes of an volved in the measurements becomes of pri­ observer. The central channel lies in a median mary importance. The compensation of errors plane, perpendicular to the eyebase of the is based upon the geometrical knowledge of observer, and the others make angles of 1, 2. the source of errors. The human eye is in­ 4, 8, 12, and 16 degrees on each side of the volved in every photogrammetric measure­ central channel. A small vertical steel rod can ment; consequently the geometrical knowl­ slide smoothly in each channel and the rods edge of the errors due to the limi tation of the are mounted for use at visual distances of 20, human eye is very important.
    [Show full text]
  • The Nature, Testing, and Variables Influencing
    THE NATURE, TESTING, AND VARIABLES INFLUENCING FIXATION DISPARITY; ROLE OF THE FUSION LOCK 1 by Leland W. Carr with Dr. James J. Saladin I ... *I Tl.e N.-1• .._1 Tufi"), A.l IJ.,.;.,l/.s I.{l..•• :? F1*'/:·.., /);,,_,. ; ~ R.lc. OF 'Tlc. ~="••1•.. C. •• l( I Introduction A fixation disparity is a small angular measurement of the mis­ alignment of the two eyes which can occur while still permitting single, fused binocular vision. It represents a small error in the aiming of the eyes which occurs without diplopia being detected. Fixation disparity is allowed because of the slight "slippage" pro­ vided to the fusional system through the existence of Panum's fusional areas. So long as binocular alignment is precise enough to place the two retinal images of a single object within corre­ sponding Panum's areas, the final perception is likely to be single and fused. Sensory fusion thus occurs in spite of a small error in motor fusion. A slight muscle imbalance is the rule, rather than the excep­ tion in individuals even with normal assymptomatic binocular systems. It is rare that all twelve extraocular muscles are precisely bal­ anced in their agonist-antagonist relationships, and thus the inate drive to achieve single vision requires a fusional effort to over­ come existing imbalance. When binocularity is dissociated (as with a covertest) the fusional drive is interrupted and the eyes deviate out of alignment under the influence of the muscle imbalance. This deviation under dissociation is referred to as the heterophoria. When both eyes are permitted to view without dissociative conditions the fusional drive to achieve single binocular vision pulls the eyes toward alignment in opposition to the phoric "stress" operating to deviate the alignment.
    [Show full text]
  • Care of the Patient with Accommodative and Vergence Dysfunction
    OPTOMETRIC CLINICAL PRACTICE GUIDELINE Care of the Patient with Accommodative and Vergence Dysfunction OPTOMETRY: THE PRIMARY EYE CARE PROFESSION Doctors of optometry are independent primary health care providers who examine, diagnose, treat, and manage diseases and disorders of the visual system, the eye, and associated structures as well as diagnose related systemic conditions. Optometrists provide more than two-thirds of the primary eye care services in the United States. They are more widely distributed geographically than other eye care providers and are readily accessible for the delivery of eye and vision care services. There are approximately 36,000 full-time-equivalent doctors of optometry currently in practice in the United States. Optometrists practice in more than 6,500 communities across the United States, serving as the sole primary eye care providers in more than 3,500 communities. The mission of the profession of optometry is to fulfill the vision and eye care needs of the public through clinical care, research, and education, all of which enhance the quality of life. OPTOMETRIC CLINICAL PRACTICE GUIDELINE CARE OF THE PATIENT WITH ACCOMMODATIVE AND VERGENCE DYSFUNCTION Reference Guide for Clinicians Prepared by the American Optometric Association Consensus Panel on Care of the Patient with Accommodative and Vergence Dysfunction: Jeffrey S. Cooper, M.S., O.D., Principal Author Carole R. Burns, O.D. Susan A. Cotter, O.D. Kent M. Daum, O.D., Ph.D. John R. Griffin, M.S., O.D. Mitchell M. Scheiman, O.D. Revised by: Jeffrey S. Cooper, M.S., O.D. December 2010 Reviewed by the AOA Clinical Guidelines Coordinating Committee: David A.
    [Show full text]
  • Brock String and the Horopter: a Perspective
    Brock String and the with neurological disorders such as cerebral 2 3 Horopter: A Perspective palsy and traumatic brain injury. A question that has been posed to us on Kenneth J. Ciuffreda, OD, PhD, more than one occasion, frequently with a FAAO, FCOVD-A, FARVO look ranging from inquisitiveness to distain, Diana P. Ludlam, BS, COVT is, “Why the horopter?” Certainly, this is a fair question. Unfortunately, the horopter seems Barry Tannen, OD, FCOVD to be misunderstood by many, and hence Naveen K. Yadav, BS Optom, the question. In our lectures, we have always MS, PhD, FAAO emphasized the concept of the horopter and its clinical importance, with its clinical analog being the all-important “Brock String.”4 Our Over the past number of years, we immediate reply to this question has been, have been involved in the teaching “Why not, as the concept of the horopter is of both normal and abnormal the underpinning for, and basis of, nearly ALL binocular vision at several optometry aspects of normal and abnormal binocular colleges, national and international vision”. This answer usually results in a pause, vision meetings, and vision research sometimes followed by the request for an institutes and hospitals. This has explanation, which we gladly provide in great involved both the underlying detail with numerous clinical examples. theory and its multitude of clinical The horopter is a wonderful pedagogical implications, including the sensory, and clinical tool, as it blends and integrates PERSPECTIVE motor, and perceptual domains and basic aspects
    [Show full text]
  • Comparison of a Unique Anaglyphic Vertical Fixation Disparity Test to the Sheedy Disparometer
    Pacific University CommonKnowledge College of Optometry Theses, Dissertations and Capstone Projects 5-2003 Comparison of a unique anaglyphic vertical fixation disparity test to the Sheedy disparometer Paul Stasik Pacific University Randy Kelly Pacific University Matt Hoppe Pacific University Recommended Citation Stasik, Paul; Kelly, Randy; and Hoppe, Matt, "Comparison of a unique anaglyphic vertical fixation disparity test to the Sheedy disparometer" (2003). College of Optometry. 1456. https://commons.pacificu.edu/opt/1456 This Thesis is brought to you for free and open access by the Theses, Dissertations and Capstone Projects at CommonKnowledge. It has been accepted for inclusion in College of Optometry by an authorized administrator of CommonKnowledge. For more information, please contact [email protected]. Comparison of a unique anaglyphic vertical fixation disparity test ot the Sheedy disparometer Abstract The clinical gold standard for deriving vertical prism prescriptions is the patient's vertical associated phoria (The relieving prism to bring a vertical fixation disparity ot zero). It is generally accepted that the most accurate device used to measure fixation disparity at nearpoint is the Sheedy disparometer. However, the Sheedy disparometer is relatively large, expensive and not currently manufactured. These factors may make measurements of vertical associated phorias less appealing and accessible to practitioners. This study evaluated the vertical associated phoria measurements of twenty non- asthenopic subjects with measurable vertical phorias. Vertical associated phoria measurements were made using the Sheedy disparometer and a unique inexpensive anaglyphic vertical fixation disparity test composed of a card with a specifically designed edr and green image and a pair of standard anaglyphic glasses for the patient to wear.
    [Show full text]
  • Causing and Curing Infantile Esotropia in Primates
    Washington University School of Medicine Digital Commons@Becker Open Access Publications 2007 Causing and curing infantile esotropia in primates: The oler of decorrelated binocular input (an American Ophthalmological Society thesis) Lawrence Tychsen Washington University School of Medicine in St. Louis Follow this and additional works at: https://digitalcommons.wustl.edu/open_access_pubs Recommended Citation Tychsen, Lawrence, ,"Causing and curing infantile esotropia in primates: The or le of decorrelated binocular input (an American Ophthalmological Society thesis)." Transactions of the American Ophthalmological Society.105,. 564-593. (2007). https://digitalcommons.wustl.edu/open_access_pubs/3298 This Open Access Publication is brought to you for free and open access by Digital Commons@Becker. It has been accepted for inclusion in Open Access Publications by an authorized administrator of Digital Commons@Becker. For more information, please contact [email protected]. CAUSING AND CURING INFANTILE ESOTROPIA IN PRIMATES: THE ROLE OF DECORRELATED BINOCULAR INPUT (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS) BY Lawrence Tychsen, MD ABSTRACT Purpose: Human infants at greatest risk for esotropia are those who suffer cerebral insults that could decorrelate signals from the 2 eyes during an early critical period of binocular, visuomotor development. The author reared normal infant monkeys, under conditions of binocular decorrelation, to determine if this alone was sufficient to cause esotropia and associated behavioral as well as neuroanatomic deficits. Methods: Binocular decorrelation was imposed using prism-goggles for durations of 3 to 24 weeks (in 6 experimental, 2 control monkeys). Behavioral recordings were obtained, followed by neuroanatomic analysis of ocular dominance columns and binocular, horizontal connections in the striate visual cortex (area V1).
    [Show full text]
  • Binocular Vision
    0331—Foundations of Clinical Ophthalmology—Ch24—R2—05-21-04 15:35:55— advantage in detection of faint images and rejection of the optical distortions within the eyes. 24 4. The presence of two mobile eyes allows the organism to converge the line of sight on distant objects and obtain a reading as to their absolute distance. 5. And, probably the most dramatic reason for binocu- Binocular lar vision, two eyes permit stereoscopic depth per- ception–the ability to use the differences in the im- ages caused by each eye viewing from a slightly Vision different viewpoint, known as binocular disparities, to perceive distance in the third dimension of visual space. Presumably all animals develop a visual system with Christopher W. Tyler some weighting among these different factors. Most lower animals take advantage of the possibility of a 360- degree field of view by having the eyes pointing in op- posite directions. This advantage applies to fish, many birds, and to a large extent, mammals that are preyed upon. However, most predatory animals, from spiders and crustaceans through birds to mammals and humans, Eyes come in pairs, providing special capabilities that tend to have the eyes facing in the same direction. This are not available to a single imaging system. This chap- arrangement is, presumably, to take advantage of stereo- ter provides an overview of the ways that visual process- scopic depth perception, which has been demonstrated ing has evolved to utilize the joint capabilities of a dual in humans, monkeys, cats, and falcons, and is likely to optical system for the perception of the third spatial be widespread across other species.2–5 dimension, of the visual deficits that can occur specific Actually, almost all animals show some degree of to the binocular coupling of this system, and of current binocular overlap, even those with a full 360-degree approaches to ameliorating those deficits.
    [Show full text]
  • Foveal Diplopia Thresholds and Fixation Disparities
    Perception & Psychophysics 1981.30 (4), 321·329 Foveal diplopia thresholds and fixation disparities A.L.DUWAER and G. van den BRINK Department ofBiologicaland Medical Physics, Erasmus University Rotterdam' 3000DR Rotterdam, The Netherlands Comparison of the magnitude and intrinsic spread of foveal diplopia thresholds with the ac­ curacy of ocular alignment as determined with a subjective alignment method shows that: the accuracy of alignment in the vertical direction (within 1-2 min) is remarkably good and much better than in the horizontal direction; the largest disparities occurring due to restricted align­ ment accuracy are usually substantially smaller than the foveal diplopia thresholds; inter­ individual variability in the magnitude of foveal diplopia thresholds is not due only to inter­ individual variability in the alignment accuracy; and the spread of foveal diplopia thresholds exceeds the spread of ocular alignment, which implies that the noise in the foveal disparity do­ main is not only due to the restricted alignment accuracy but also to sensory processes. Finally, the data confirm that, unlike the case with diplopia thresholds, the spread of stereoscopic thresholds is not affected by the restricted alignment accuracy. When an observer with normal binocular vision but also for the reported foveal diplopia thresholds looks with both eyes at an object, the eyes align with (see, e.g., Ouwaer & van den Brink, 1981). respect to the fixated part of the object in such a way Because of these variabilities, the comparative that the images in the foveae of the two eyes fall on magnitudes of fixation disparities and foveal dip­ nearly corresponding retinal locations.
    [Show full text]
  • Accommodative and Vergence Dysfunction
    OPTOMETRY: OPTOMETRIC CLINICAL THE PRIMARY EYE CARE PROFESSION PRACTICE GUIDELINE Doctors of optometry are independent primary health care providers who examine, diagnose, treat, and manage diseases and disorders of the visual system, the eye, and associated structures as well as diagnose related systemic conditions. Optometrists provide more than two-thirds of the primary eye care services in the United States. They are more widely distributed geographically than other eye care providers and are readily accessible for the delivery of eye and vision care services. There are approximately 32,000 full-time equivalent doctors of optometry currently in practice in the United States. Optometrists practice in more than 7,000 communities across the United States, serving as the sole primary eye care provider in more than 4,300 communities. Care of the Patient with The mission of the profession of optometry is to fulfill the vision and eye Accommodative and care needs of the public through clinical care, research, and education, all of which enhance the quality of life. Vergence Dysfunction OPTOMETRIC CLINICAL PRACTICE GUIDELINE CARE OF THE PATIENT WITH ACCOMMODATIVE AND VERGENCE DYSFUNCTION Reference Guide for Clinicians Prepared by the American Optometric Association Consensus Panel on Care of the Patient with Accommodative or Vergence Dysfunction: Jeffrey S. Cooper, M.S., O.D., Principal Author Carole R. Burns, O.D. Susan A. Cotter, O.D. Kent M. Daum, O.D., Ph.D. John R. Griffin, M.S., O.D. Mitchell M. Scheiman, O.D. Reviewed by the AOA Clinical Guidelines Coordinating Committee: John F. Amos, O.D., M.S., Chair Kerry L.
    [Show full text]
  • Aspects of Fixation Disparity During Reading
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Journal of Eye Movement Research Journal of Eye Movement Research 3(3):1, 1-13 “Trait” and “state” aspects of fixation disparity during reading Stephanie Jainta Wolfgang Jaschinski Leibniz Research Centre for Working Leibniz Research Centre for Working Environment and Human Factors Environment and Human Factors In our study, 14 subjects read 60 sentences from the Potsdam Sentence Corpus twice (viewing distance: 60 cm), while eye movements were measured with the EyeLink II. We analyzed fixation disparities for complete sentence replications (N=388). After subtracting the average fixation disparity of each sentence from each observation (which gave the “state” fixation disparity), 99% of all remaining fixation disparities were aligned, i.e. smaller than one character width (20 min arc) – depending mostly on incoming saccade amplitude and fixation position. Additionally, we measured the heterophoria for each sub- ject during calibration and found a qualitative relationship between average, individual measures of fixation disparity (“trait” fixation disparity) and heterophoria, after dividing the sample in 3 groups of esophore, exophore and orthophore subjects. We showed that the magnitude of “trait” fixation disparity was biased by the direction of heterophoria: the more eso the heterophoria, the more eso the average sentence fixation disparity. In sum, despite a large “trait” fixation disparity (in the range of -6.6 to +33.6 min arc), “state” fixation disparities within a sentence were on average -0.9 (± 8.7) min arc and, thus, as precise as needed, i.e. within the expected extent of Panum’s area.
    [Show full text]