Circuit protection devices
MCBs, RCCBs, RCBO, ELR, surge arresters, fuse carriers, complete range of auxiliaries, busbars and connectors
EA 2002/1 Welcome to the new edition of our general catalogue
For easy reference purposes, Hager general catalogue is divided into three separate catalogues each representing the following product groups :
1. Enclosures and Connection Devices
2. Circuit Protection Devices
3. Automation and Control Equipment
A technical section, at the end of each catalogue provides detailed information of the products and its applications.
The success is in the system
1 The Hager Group
With over 6000 dedicated This has resulted in the employees worldwide, and company achieving an innovative, carefully registration to ISO 9001. structured product range, Hager is one of the leading Hager products are international manufacturers approved by all relevant of electrical distribution Standards Bodies and the systems. ongoing process of harmonisation of European Hager has 12 manufacturing and International Standards sites in France, Germany, coupled with the Hager Italy, Spain and the United ‘partnership’ business Kingdom and has an philosophy will ensure established marketing continuing success in our network throughout Europe, global marketing strategy. Asia and Australia serviced by Hager subsidiary companies.
Hager Electro Systems Pte Obernai - France Ltd - Singapore is actively progressing the development of a similar marketing network throughout Asia.
Hager products are available in over 60 countries throughout the world and benefit from a heavy investment in research and development and from rigorous quality control procedures at all stages of ISO 9001 certification Ensheim - Germany manufacture.
Tehalit headquarters in Heltersberg - Germany
Blieskastel - Germany Telford - UK
2 The Hager system
Specialists in electrical distribution systems for residential, commercial and industrial installations.
Enclosures, Consumer Units and Distribution Boards Circuit Protection Devices ♦Multi - service metal and insulated enclosures ♦ Miniature circuit breakers (MCB) ♦ Golf surface / flush mounted insulated enclosures ♦ Residual current circuit breakers (RCCB/ELCB) ♦ Vega surface mounted insulated enclosures ♦ Combined MCB / RCD (RCBOs) ♦ 30V surface mounted enclosures ♦ RCD add-on blocks ♦ Vector and Orion weatherproof enclosures ♦ Moulded case circuit breakers (MCCB) ♦ TP&N distribution boards ♦ Voltage surge protectors ♦ Earth leakage relays ♦ HRC fuse carriers ♦ Isolating switches ♦ Motor protection circuit breakers
Connection Devices Automation and Control Equipment ♦ Brass terminals ♦ Relays and latching relays ♦ Insulated busbars and links ♦ Contactors ♦ Rail mounted terminals ♦ Delay timers ♦ Accessories for connection and installation ♦ Digital and electromechanical time switches ♦ Light sensitive switches and programmers ♦ Pushbuttons ♦ Voltmeters and ammeters (digital/analogue) ♦ Digital kWh meters ♦ Transformers, bells and buzzers
3 Numerical index
Symbols used in this catalogue : I : modules ▫ : mm2
Cat.ref. Page No. Cat.ref. Page No. Cat.ref. Page No. Cat.ref. Page No. Cat.ref. Page No. Cat.ref. Page No.
0 BD 264N 15 CF 280B 16 K 162F 34 KZ 022 32 MT 306A 9 0B 0415 32 BD 285 13 CF 284B 16 KB 063N 32 KZ 022 33 MT 310A 9 BD 326N 15 CF 425B 16 KB 063P 32 KZ 023 32 MT 316A 9 A BD 341N 15 CF 440B 16 KB 163I 32 KZ 023 33 MT 320A 9 AC 007G 17 BD 364N 15 CF 463B 16 KB 190B 32 KZ 024 32 MT 325A 9 AC 022G 17 BD 385 13 CF 480B 16 KB 190C 32 KZ 024 33 MT 332A 9 AC 107 18 BD 426N 15 CF 484B 16 KB 263A 32 KZ 060 34 MT 340A 9 AC 122 18 BD 441N 15 CG 225B 16 KB 263C 32 MT 350A 9 AD 004G 17 BD 464N 15 CG 240B 16 KB 280B 32 L MT 363A 9 AD 005G 17 BD 485 13 CG 263B 16 KB 363A 32 L 113 21 MU 102A 9 AD 007G 17 BE 225N 15 CG 280B 16 KB 363B 32 L 115 21 MU 104A 9 AD 008G 17 BE 263N 15 CG 284B 16 KB 363C 32 L 116 21 MU 106A 9 AD 009G 17 BE 325N 15 CG 425B 16 KB 380A 32 L 118 21 MU 110A 9 AD 010G 17 BE 363N 15 CG 440B 16 KB 380B 32 L 153 21 MU 116A 9 AD 019G 17 BE 425N 15 CG 463B 16 KB 463A 32 L 155 21 MU 120A 9 AD 020G 17 BE 463N 15 CG 480B 16 KB 463C 32 L 156 21 MU 125A 9 AD 022G 17 BF 226N 15 CG 484B 16 KB 480A 32 L 158 21 MU 132A 9 AD 023G 17 BF 241N 15 CZ 001 14 KB 480B 32 L 501 21 MU 140A 9 AD 024G 17 BF 264N 15 CZ 005 16 KD 163A 33 L 502 21 MU 150A 9 AD 025G 17 BF 285 13 CZ 006 16 KD 163B 33 L 503 21 MU 163A 9 AD 104 18 BF 326N 15 CZ 007 16 KD 180A 33 L 504 21 MU 202A 9 AD 105 18 BF 341N 15 CZ 008 16 KD 180B 33 LR 601 22 MU 204A 9 AD 107 18 BF 364N 15 KD 190B 33 LR 602 22 MU 206A 9 AD 108 18 BF 385 13 E KD 263A 33 LR 603 22 MU 210A 9 AD 109 18 BF 426N 15 EU 100 28 KD 263B 33 LR 604 22 MU 216A 9 AD 110 18 BF 441N 15 EU 101 28 KD 280A 33 LR 701 22 MU 220A 9 AD 111 18 BF 464N 15 EU 102 29 KD 280B 33 LR 702 22 MU 225A 9 AD 112 18 BF 485 13 EU 130 29 KD 363A 33 LR 703 22 MU 232A 9 AD 113 18 BG 264N 15 EU 300 28 KD 363B 33 LR 704 22 MU 240A 9 AD 119 18 BG 364N 15 EU 301 28 KD 380A 33 MU 250A 9 AD 120 18 BG 464N 15 EU 302 29 KD 380B 33 M MU 263A 9 AD 122 18 BP 264N 15 KD 463A 33 MM 501N 23 MU 302A 9 AD 123 18 BP 364N 15 H KD 463B 33 MM 502N 23 MU 304A 9 AD 124 18 BP 464N 15 HR 210 19 KD 480A 33 MM 503N 23 MU 306A 9 AD 125 18 BR 264N 15 HR 220 19 KD 480B 33 MM 504N 23 MU 310A 9 AD 126 18 BR 364N 15 HR 223 19 KF 81A 32 MM 505N 23 MU 316A 9 AD 127 18 BR 464N 15 HR 228 19 KF 82A 32 MM 506N 23 MU 320A 9 AD 128 18 HR 910 20 KF 83A 32 MM 507N 23 MU 325A 9 AD 184 18 C HR 911 20 KF 84A 32 MM 508N 23 MU 332A 9 AD 185 18 CC 216B 16 HR 912 20 KF 84A 33 MM 509N 23 MU 340A 9 AD 187 18 CC 225B 16 HR 913 20 KM 04L 34 MM 510N 23 MU 350A 9 AD 188 18 CD 216B 16 HR 920 20 KM 07E 34 MM 511N 23 MU 363A 9 AD 189 18 CD 225B 16 HR 921 20 KM 07L 34 MM 512N 23 MY 101 8 AD 190 18 CD 240B 16 HR 922 20 KM 07N 34 MM 513N 23 MY 102 8 AD 191 18 CD 263B 16 KM 08L 34 MM 520N 23 MY 103 8 AE 019G 17 CD 280B 16 J KM 10A 34 MT 106A 9 MY 104 8 AE 020G 17 CD 284B 16 JF 81D 33 KM 10B 34 MT 110A 9 MY 105 8 AE 022G 17 CD 425B 16 KM 10C 34 MT 116A 9 MY 106 8 AE 023G 17 CD 440B 16 K KM 10E 34 MT 120A 9 MY 110 8 AE 024G 17 CD 463B 16 K 018F 35 KM 10L 34 MT 125A 9 MY 116 8 AE 025G 17 CD 480B 16 K 023F 35 KM 10N 34 MT 132A 9 MY 120 8 AE 106Z 18 CD 484B 16 K 024F 35 KM 11B 34 MT 140A 9 MY 125 8 AE 110Z 18 CE 225B 16 K 025F 35 KM 11E 34 MT 150A 9 MY 132 8 AE 116Z 18 CE 240B 16 K 037F 35 KM 11L 34 MT 163A 9 MY 140 8 AE 120Z 18 CE 263B 16 K 140F 34 KM 11N 34 MT 206A 9 MY 150 8 AE 125Z 18 CE 280B 16 K 142F 34 KM 13E 34 MT 210A 9 MY 163 8 AE 132Z 18 CE 284B 16 K 143F 34 KM 13N 34 MT 216A 9 MY 201 8 AE 140Z 18 CE 425B 16 K 144F 34 KM 17E 34 MT 220A 9 MY 202 8 AE 145Z 18 CE 440B 16 K 145F 34 KM 17N 34 MT 225A 9 MY 203 8 AE 150Z 18 CE 463B 16 K 148F 34 KM 25E 34 MT 232A 9 MY 204 8 CE 480B 16 K 151F 34 KM 25N 34 MT 240A 9 MY 205 8 B CE 484B 16 K 156F 34 KZ 012 34 MT 250A 9 MY 206 8 BC 225N 15 CF 225B 16 K 158F 34 KZ 013 34 MT 263A 9 MY 210 8 BD 214N 15 CF 240B 16 K 159F 34 KZ 014 34 MT 302A 9 MY 216 8 BD 226N 15 CF 263B 16 K 160F 34 KZ 021 32 MT 304A 9 MY 220 8
4 Numerical index
Symbols used in this catalogue : I : modules ▫ : mm2
Cat.ref. Page No. Cat.ref. Page No. Cat.ref. Page No. Cat.ref. Page No. Cat.ref. Page No. Cat.ref. Page No.
MY 225 8 NB 340A 11 NC 403A 11 NM 390 13 SB 416S 27 MY 232 8 NB 350A 11 NC 404A 11 NM 480 13 SB 432Q 27 MY 240 8 NB 363A 11 NC 406A 11 NM 484 13 SB 432S 27 MY 250 8 NB 380A 11 NC 410A 11 NM 490 13 SB 440S 27 MY 263 8 NB 399A 11 NC 416A 11 NR 106A 12 SB 463S 27 MY 301 8 NB 406A 11 NC 420A 11 NR 110A 12 SB 480S 27 MY 302 8 NB 410A 11 NC 425A 11 NR 116A 12 SB 499S 27 MY 303 8 NB 416A 11 NC 432A 11 NR 120A 12 SF 115 27 MY 304 8 NB 420A 11 NC 440A 11 NR 125A 12 SF 118F 27 MY 305 8 NB 425A 11 NC 450A 11 NR 132A 12 SF 119F 27 MY 306 8 NB 432A 11 NC 463A 11 NR 140A 12 SF 218F 27 MY 310 8 NB 440A 11 NC 480A 11 NR 150A 12 SF 219F 27 MY 316 8 NB 450A 11 NC 499A 11 NR 163A 12 SF 232F 27 MY 320 8 NB 463A 11 ND 106A 10 NR 206A 12 SP 140D 24 MY 325 8 NB 480A 11 ND 110A 10 NR 210A 12 SP 140R 24 MY 332 8 NB 499A 11 ND 116A 10 NR 216A 12 SP 165R 24 MY 340 8 NC 100A 10 ND 120A 10 NR 220A 12 SP 208 24 MY 350 8 NC 101A 10 ND 125A 10 NR 225A 12 SP 208S 25 MY 363 8 NC 102A 10 ND 132A 10 NR 232A 12 SP 210 25 MZ 011 14 NC 103A 10 ND 140A 10 NR 240A 12 SP 215D 24 MZ 012 14 NC 104A 10 ND 150A 10 NR 250A 12 SP 215R 24 MZ 013 14 NC 106A 10 ND 163A 10 NR 263A 12 SP 225 25 MZ 014 14 NC 110A 10 ND 180 10 NR 306A 12 SP 415D 24 MZ 015 14 NC 116A 10 ND 184 10 NR 310A 12 SP 415R 24 MZ 175 14 NC 120A 10 ND 206A 10 NR 316A 12 MZ 175 16 NC 125A 10 ND 210A 10 NR 320A 12 MZ 201 14 NC 132A 10 ND 216A 10 NR 325A 12 MZ 202 14 NC 140A 10 ND 220A 10 NR 332A 12 MZ 203 14 NC 150A 10 ND 225A 10 NR 340A 12 MZ 204 14 NC 163A 10 ND 232A 10 NR 350A 12 MZ 205 14 NC 200A 10 ND 240A 10 NR 363A 12 MZ 206 14 NC 201A 10 ND 250A 10 NR 406A 12 MZ 521N 23 NC 202A 10 ND 263A 10 NR 410A 12 MZ 527N 23 NC 203A 10 ND 280 10 NR 416A 12 MZ 528N 23 NC 204A 10 ND 284 10 NR 420A 12 MZ 529N 23 NC 206A 10 ND 306A 11 NR 425A 12 MZ 530N 23 NC 210A 10 ND 310A 11 NR 432A 12 NC 216A 10 ND 316A 11 NR 440A 12 N NC 220A 10 ND 320A 11 NR 450A 12 NB 106A 10 NC 225A 10 ND 325A 11 NR 463A 12 NB 110A 10 NC 232A 10 ND 332A 11 NB 116A 10 NC 240A 10 ND 340A 11 S NB 120A 10 NC 250A 10 ND 350A 11 SB 106S 26 NB 125A 10 NC 263A 10 ND 363A 11 SB 116S 26 NB 132A 10 NC 280A 10 ND 380 11 SB 132S 26 NB 140A 10 NC 299A 10 ND 384 11 SB 140S 26 NB 150A 10 NC 300A 11 ND 406A 11 SB 163S 26 NB 163A 10 NC 301A 11 ND 410A 11 SB 180S 26 NB 206A 10 NC 302A 11 ND 416A 11 SB 199S 26 NB 210A 10 NC 303A 11 ND 420A 11 SB 216S 26 NB 216A 10 NC 304A 11 ND 425A 11 SB 232Q 26 NB 220A 10 NC 306A 11 ND 432A 11 SB 232S 26 NB 225A 10 NC 310A 11 ND 440A 11 SB 240S 26 NB 232A 10 NC 316A 11 ND 450A 11 SB 260S 26 NB 240A 10 NC 320A 11 ND 463A 11 SB 263S 26 NB 250A 10 NC 325A 11 ND 480 11 SB 280S 26 NB 263A 10 NC 332A 11 ND 484 11 SB 299S 26 NB 280A 10 NC 340A 11 NM 180 13 SB 306S 26 NB 299A 10 NC 350A 11 NM 184 13 SB 316S 26 NB 306A 11 NC 363A 11 NM 190 13 SB 332S 26 NB 310A 11 NC 380A 11 NM 280 13 SB 340Q 26 NB 316A 11 NC 399A 11 NM 284 13 SB 340S 26 NB 320A 11 NC 400A 11 NM 290 13 SB 363S 26 NB 325A 11 NC 401A 11 NM 380 13 SB 380S 26 NB 332A 11 NC 402A 11 NM 384 13 SB 399S 26
5 Circuit protection devices
8 Miniature circuit breakers 14 Auxiliaries and accessories for MCBs & RCCBs 15 RCD add-on blocks 16 2 and 4 pole residual current devices (RCCBs/ELCBs) 17 Combined MCB/RCD (RCBO) 18 RCBO electronic 19 Earth leakage relays 21 HRC fuse carriers and fuses 22 L51-L58 HRC fuse carriers 23 Motor starters 24 Surge protection devices (SPD) 26 Isolating switches 28 Control relays
7 Miniature circuit breakers 4.5kA type C - MY
68 Description voltage rating : 230/400V 44 protection and control of circuits mechanical endurance : against overloads and short cir- 20 000 operations cuits in domestic, commercial and industrial applications. Connection capacity : ▫ 25 rigid conductor ▫ Technical data 16 flexible conductor C curve tripping current rating : 1-63A Will accept accessories, shunt 45 breaking capacity : trips, auxiliary contact. 4.5kA IEC898 see page 12 6kA IEC947-2 10KAIC NEMA AB-1 Approval : For technical information reference calibration KEMA see page 38 temperature : 30°C JBE
Designation In/A Width in I Pack Cat. 17.5mm qty. ref.
Single pole MCB 1112MY 101 2112MY 102 3112MY 103 4112MY 104 6112MY 106 10 1 12 MY 110 16 1 12 MY 116 20 1 12 MY 120 25 1 12 MY 125 32 1 12 MY 132 MY 120 40 1 12 MY 140 50 1 12 MY 150 63 1 12 MY 163
Double pole MCB 126MY 201 226MY 202 326MY 203 426MY 204 626MY 206 10 2 6 MY 210 16 2 6 MY 216 20 2 6 MY 220 25 2 6 MY 225 32 2 6 MY 232 MY 220 40 2 6 MY 240 50 2 6 MY 250 63 2 6 MY 263
Triple pole MCB 134MY 301 234MY 302 334MY 303 434MY 304 634MY 306 10 3 4 MY 310 16 3 4 MY 316 20 3 4 MY 320 25 3 4 MY 325 32 3 4 MY 332 MY 316 40 3 4 MY 340 50 3 4 MY 350 63 3 4 MY 363
8 Miniature circuit breakers 6kA type B and C - MT MU
68 Description 10kA IEC 947-2 44 protection and control of circuits 22KAIC NEMA AB-1 against overloads and short cir- voltage rating : 230/400V cuits in domestic, commercial current rating : 2-63A and industrial applications. mechanical endurance : 20 000 operations Technical data MTxxxA = type B tripping Connection capacity : ▫ MUxxxA = type C tripping 25 rigid conductor 45 ▫ according to IEC898 and 16 flexible conductor BSEN 60-898 reference calibration Will accept accessories, shunt temperature : 30°C trips, auxiliary contact. For technical information breaking capacity : see page 12 see page 38 6kA IEC898
Designation In/A Width in I Pack B curve C curve 17.5mm qty. cat. ref. cat.ref.
Single pole MCB 2112MU 102A 4112MU 104A 6112MT 106A MU 106A 10 1 12 MT 110A MU 110A 16 1 12 MT 116A MU 116A 20 1 12 MT 120A MU 120A 25 1 12 MT 125A MU 125A 32 1 12 MT 132A MU 132A 40 1 12 MT 140A MU 140A 50 1 12 MT 150A MU 150A 63 1 12 MT 163A MU 163A MT 116A Double pole MCB 226MU 202A 426MU 204A 626MT 206A MU 206A 10 2 6 MT 210A MU 210A 16 2 6 MT 216A MU 216A 20 2 6 MT 220A MU 220A 25 2 6 MT 225A MU 225A 32 2 6 MT 232A MU 232A 40 2 6 MT 240A MU 240A 50 2 6 MT 250A MU 250A 63 2 6 MT 263A MU 263A
Triple pole MCB 234MT 302A MU 302A MT 220A 434MT 304A MU 304A 634MT 306A MU 306A 10 3 4 MT 310A MU 310A 16 3 4 MT 316A MU 316A 20 3 4 MT 320A MU 320A 25 3 4 MT 325A MU 325A 32 3 4 MT 332A MU 332A 40 3 4 MT 340A MU 340A 50 3 4 MT 350A MU 350A 63 3 4 MT 363A MU 363A
MT 320A
9 Miniature circuit breakers 10kA type B, C and D - NB NC ND ...
68 Description 15kA according to IEC947-2 see page 12 44 protection and control of circuits 30KAIC accordig to NEMA AB-1 against overloads and short reference calibration Connection capacity circuits in domestic, commercial temperature : 30°C (up to 63A) : ▫ and industrial electrical distribu- voltage rating : 230/400V 25 rigid conductor ▫ tion systems. curent rating : 0.5 - 100A 16 flexible conductor mechanical endurance : Technical data 20 000 operations Connection capacity (80/100A): ▫ NBxxxA = type B tripping 50 rigid conductor 45 ▫ NCxxxA = type C tripping Positive contact indication 35 flexible conductor NDxxxA = type D tripping red - contacts closed according to IEC898 and BSEN green - contacts open 60-898 For technical information breaking capacity : Will accept accessories, shunt see page 38 10kA according to IEC898 trips, auxiliary contact.
Designation In/A Width in I Pack B curve C curve D curve 17.5mm qty. cat. ref. cat.ref. cat.ref.
Single pole MCB 0.5 1 12 NC 100A 11 12 NC 101A 21 12 NC 102A 31 12 NC 103A 41 12 NC 104A 61 12NB 106A NC 106A ND 106A 10 1 12 NB 110A NC 110A ND 110A 16 1 12 NB 116A NC 116A ND 116A 20 1 12 NB 120A NC 120A ND 120A 25 1 12 NB 125A NC 125A ND 125A NC 116A 32 1 12 NB 132A NC 132A ND 132A 40 1 12 NB 140A NC 140A ND 140A 50 1 12 NB 150A NC 150A ND 150A 63 1 12 NB 163A NC163A ND 163A 80 1.5 1 ND 180 100 1.5 1 ND 184
Double pole MCB 0.5 2 6 NC 200A 12 6 NC 201A 22 6 NC 202A 32 6 NC 203A 42 6 NC 204A 62 6NB 206A NC 206A ND 206A 10 2 6 NB 210A NC 210A ND 210A 16 2 6 NB 216A NC 216A ND 216A 20 2 6 NB 220A NC 220A ND 220A 25 2 6 NB 225A NC 225A ND 225A NC 220A 32 2 6 NB 232A NC 232A ND 232A 40 2 6 NB 240A NC 240A ND 240A 50 2 6 NB 250A NC 250A ND 250A 63 2 6 NB 263A NC 263A ND 263A 80 3 1 NB 280A NC 280A ND 280 100 3 1 NB 299A NB 299A ND 284
10 ... Miniature circuit breakers 10kA type B, C and D - NB NC ND
Designation In/A Width in I Pack B curve C curve D curve 17.5mm qty. cat. ref. cat.ref. cat.ref.
Triple pole MCB 0.5 3 4 NC 300A 13 4 NC 301A 23 4 NC 302A 33 4 NC 303A 43 4 NC 304A 63 4NB 306A NC 306A ND 306A 10 3 4 NB 310A NC 310A ND 310A 16 3 4 NB 316A NC 316A ND 316A 20 3 4 NB 320A NC 320A ND 320A 25 3 4 NB 325A NC 325A ND 325A NC 320A 32 3 4 NB 332A NC 332A ND 332A 40 3 4 NB 340A NC 340A ND 340A 50 3 4 NB 350A NC 350A ND 350A 63 3 4 NB 363A NC 363A ND 363A 80 4.5 1 NB 380A* NC 380A* ND 380 100 4.5 1 NB 399A* NC 399A* ND 384
Four pole MCB 0.5 4 3 NC 400A 14 3 NC 401A 24 3 NC 402A 34 3 NC 403A 44 3 NC 404A 64 3NB 406A NC 406A ND 406A 10 4 3 NB 410A NC 410A ND 410A 16 4 3 NB 416A NC 416A ND 416A 20 4 3 NB 420A NC 420A ND 420A 25 4 3 NB 425A NC 425A ND 425A NC 425A 32 4 3 NB 432A NC 432A ND 432A 40 4 3 NB 440A NC 440A ND 440A 50 4 3 NB 450A NC 450A ND 450A 63 4 3 NB 463A NC 463A ND 463A 80 6 1 NB 480A* NC 480A* ND 480 100 6 1 NB 499A* NB 499A* ND 484
* 6kA IEC 898, 10kA IEC 947-2
11 Miniature circuit breakers 15/25kA type C - NR
68 Description voltage rating - 230-400V Connection capacity ▫ 44 protection and control of circuits current rating - 6-63A 25 rigid conductor ▫ against overloads and short electrical endurance : 16 flexible conductor circuits in commercial and 20 000 operations industrial electrical distribution systems. Positive contact indication red - contacts closed Technical data green - contacts open type C tripping characteristics 45 reference calibration Will accept accessories, shunt temperature : 40°C trips, auxiliary contact. breaking capacity to IEC 947-2 see page 12 - 25 000A ( ≤ 20A) For technical information - 20 000A (25 to 40A) see page 38 - 15 000A (50 to 63A)
Designation breaking In/A Width in I Pack cat. capacity kA 17.5mm qty. ref.
Single pole MCB 25 6 1 12 NR 106A 25 10 1 12 NR 110A 25 16 1 12 NR 116A 25 20 1 12 NR 120A 20 25 1 12 NR 125A 20 32 1 12 NR 132A 20 40 1 12 NR 140A 15 50 1 12 NR 150A 15 63 1 12 NR 163A
NR 110A
Double pole MCB 25 6 2 6 NR 206A 25 10 2 6 NR 210A 25 16 2 6 NR 216A 25 20 2 6 NR 220A 20 25 2 6 NR 225A 20 32 2 6 NR 232A 20 40 2 6 NR 240A 15 50 2 6 NR 250A 15 63 2 6 NR 263A
NC 232A Triple pole MCB 25 6 3 4 NR 306A 25 10 3 4 NR 310A 25 16 3 4 NR 316A 25 20 3 4 NR 320A 20 25 3 4 NR 325A 20 32 3 4 NR 332A 20 40 3 4 NR 340A 15 50 3 4 NR 350A 15 63 3 4 NR 363A
Four pole MCB 25 6 4 3 NR 406A 25 10 4 3 NR 410A 25 16 4 3 NR 416A NC 340A 25 20 4 3 NR 420A 20 25 4 3 NR 425A 20 32 4 3 NR 432A 20 40 4 3 NR 440A 15 50 4 3 NR 450A 15 63 4 3 NR 463A
NC 440A
12 Miniature circuit breakers 10kA type C - NM
Description Technical data Positive contact indication protection and control of circuits type C tripping characteristics to red - contacts closed against overloads and short IEC 947-2 green - contacts open circuits in commercial and magnetic setting : 5-10In industrial installations. breaking capacity : 10 000A Connection capacity : ▫ reference calibration rigid conductor 50 ▫ temperature : 40°C flexible conductor 35 voltage rating : 230-400V current rating : 80-125A Options mechanical endurance : 20 000 auxiliary contact, shunt trip, ambient temperature range : locking kit - see page 12 -5°C to +40°C tropicalisation T2 For technical information see page 38
Designation In/A Width in I Pack. C curve 17.5mm qty. cat. ref.
Single pole MCB 80 1.5 1 NM 180 100 1.5 1 NM 184 125 1.5 1 NM 190
Double pole MCB 80 3 1 NM 280 100 3 1 NM 284 125 3 1 NM 290
Triple pole MCB 80 4.5 1 NM 380 100 4.5 1 NM 384 125 4.5 1 NM 390 NM 280 Four pole MCB 80 6 1 NM 480 100 6 1 NM 484 125 6 1 NM 490
RCD add-on blocks - NM
RCD add-on block for NM and Nuisance tripping NB/NC 80 and 100A MCBs as with all Hager devices the these devices are designed to add-on blocks are protected be fitted to the right hand side of against nuisance tripping caused 2, 3 or 4 pole 80 and 100A cir- by transient leakage currents cuit breakers to provide earth leakage protection Connection capacity : ▫ the combination device then rigid conductor 50 ▫ provides protection against over- flexible conductor 35 For technical information loads, shor circuits and earth see page 41 leakage faults all devices have a test facility
Designation Sensitivity Width in I Pack. Cat. 17.5mm qty. ref.
2 pole 30mA 2.5 1 BD 285 RCD add-on block 300mA 2.5 1 BF 285
3 pole 30mA 4.5 1 BD 385 RCD add-on block 300mA 4.5 1 BF 385
4 pole 30mA 4.5 1 BD 485 RCD add-on block 300mA 4.5 1 BF 485
BD 285 13 Auxiliaries and accessories for MCBs & RCCBs
All auxiliaries are common to Test mode for CZ001, MZ201, For technical information both single and multi-pole circuit MZ202 : possible to test cabling see page 40 breakers. These auxiliaries are of auxiliary circuits operation by fitted to the left hand side of tripping-over contacts manually. CZ001 must be fitted on the devices. Resetting of contact occurs RCCB before fitting maximum Fault indication, auxiliaries, simultaneously with MCB/RCCB one additional auxiliary (MZ203 shunt trips, and under-voltage resetting. to MZ206). releases are fitted with a flag Up to 4 auxiliaries can be fitted indicator that indicates the auto- on MCB. matic/remote tripping of the device.
Designation Description Width inI Pack cat. cat. 17.5mm qty. ref. ref. (1)
Auxiliary and signal 1NO + 1NC auxiliary contact CA 1 1 CZ 001 contacts for RCCBs 6A - 230V~ 1NO + 1NC signal contact SD 3A - 440V~ can only be fitted to CC, CD, CE, CF, CG range of RCCBs allows remote indication of contact position and acts as an adaptor to fit additional shunt trip coil or undervoltage MZ 201 release
Auxiliay contacts 1NO + 1NC auxiliary contact 1/2 1 MZ 201 MZ 011 6A - 230V~ 3A - 440V~ allows remote indication of main contact status. 13 21
14 22
Signal contacts 1NO + 1NC signal contact 1/2 1 MZ 202 MZ 012 6A - 230V~ MZ 204 3A - 440V~ signal contact indicates a fault condition (e.g. MCB tripped on overload or short circuit).
flag indicator 91 red - MCB tripped 92
93
94
Shunt trip 230 - 415 Vac 1 1 MZ 203 MZ 013 allows remote tripping 110 - 130 Vdc of the device
C 1 12 - 48 Vdc 1 1 MZ 204 MZ 014
C 2 24 - 48 Vac MZ 205
Under voltage release allows MCB to be closed only when voltage is above 70% of Un. MCB will automatically trip when voltage falls by 35% of Un D 1 48 Vdc 1 1 MZ 205 U < 230 Vac 1 1 MZ 206 MZ 015 D 2 Locking kit this allows locking of the device 2 MZ 175 MZ 175 for the dolly of the device dolly in the on/off position. suuplied without padlock. will accept two padlocks with MZ 175 hasps of 4.75mm diameter max.
14 (1) Auxiliaries for NM.90, ND.80 and ND.84 RCD add-on blocks
62 Description All devices have a test facility 44 RCD add-on blocks for use with All devices except 10mA and MCB ranges MY, MT, MU, NB, 100mA, are type AC. NC, ND, NR up to 63A. 10mA and 100mA are type A. All devices are protected against Technical data : nuisance tripping and transient High sensitivity : voltages 10-30 mA instant tripping
45 Medium sensitivity : Nominal voltage : 100-500 mA instant tripping 2 poles 230V 300 - 500mA selective (time 3 and 4 poles : 230/400V delay) S Comply with IEC1009 These devices are designed to be fitted on the right hand side Connection capacities : of the 2, 3 and 4 poles MCB’s. 25 A : 6▫ flexible cable 10▫ rigid cable The combination device then 40, 63 A : 16▫ flexible cable provides protection against 25▫ rigid cable overload, short circuits and For technical information earth leakage faults. see page 41
Designation Type Sensitivity In/A Width in I Pack Cat. I n 17.5mm qty. ref.
2 poles add-on blocks A 10 mA 25A 2 1 BC 225N AC 30 mA 25A 2 1 BD 226N 1 3 AC 40A 2 1 BD 241N AC 63A 2 1 BD 264N A 100 mA 25A 2 1 BE 225N A 63A 2 1 BE 263N AC 300 mA 25A 2 1 BF 226N 2 4 AC 40A 2 1 BF 241N AC 63A 2 1 BF 264N AC 500 mA 63A 2 1 BG 264N ACS 300 mA 63A 2 1 BP 264N BD 226N ACS 500mA 63A 2 1 BR 264N
3 poles add-on blocks AC 30 mA 25A 2 1 BD 326N AC 40A 3 1 BD 341N 1 3 5 AC 63A 3 1 BD 364N A 100 mA 25A 3 1 BE 325N A 63A 3 1 BE 363N AC 300 mA 25A 2 1 BF 326N AC 40A 3 1 BF 341N 2 4 6 AC 63A 3 1 BF 364N BD 364N AC 500 mA 63A 3 1 BG 364N ACS 300 mA 63A 3 1 BP 364N ACS 500 mA 63A 3 1 BR 364N
4 poles add-on blocks AC 30 mA 25A 2 1 BD 426N AC 40A 3 1 BD 441N 1 3 5 7 AC 63A 3 1 BD 464N A 100mA 25A 3 1 BE 425N BD 426N A 63A 3 1 BE 463N AC 300 mA 25A 2 1 BF 426N AC 40A 3 1 BF 441N 2 4 6 8 AC 63A 3 1 BF 464N AC 500 mA 63A 3 1 BG 464N ACS 300 mA 63A 3 1 BP 464N ACS 500 mA 63A 3 1 BR 464N
15 2 and 4 pole residual current devices (RCCBs/ELCBs)
▫ Description 80-100A rigid 50 Nuisance tripping ▫ 68 to open a circuit automatically in flexible 35 all the RCCBs are protected 44 the case of an earth leakage ambient temperature range : against transient voltages (light- fault between phase and earth -5 to +40°C ning, line disturbances) and tran- and / or neutral greater or equal sient currents (from high capaci- to 10, 30, 100, 300 or 500mA; Positive contact indication : tive circuits). use in domestic, commercial and mechanical indicator, appearing DC sensitive RCCBs or time industrial installations. on the front face of the RCCB, delay devices are available, linked to the contacts shows the please consult us. Technical data positive opening of all poles,
45 nominal voltage : red = contacts closed you also have the possibility to 2 pole 110/230V - 50/60Hz green = contacts open install the following accessories : 4 pole 230/400V - 50/60Hz electrical auxiliaries specifications : IEC 1008-1 Earth fault indicator (see page 40 ) SS97 : 1994 mechanical indicator terminal cover kit appearing on the front face of locking kit Connection capacity : the RCCB to differenciate ▫ 16-63A rigid 25 between tripping and off position * without SS97 ▫ flexible 16 yellow - tripped
Sensitivity Pole Current Width in I Pack Cat. I n rating 17.5mm qty. ref.
High sensitivity 10mA 2 16A 2 1 CC 216B 2 25A 2 1 CC 225B 30mA 2 16A 2 1 CD 216B 2 25A 2 1 CD 225B 2 40A 2 1 CD 240B 2 63A 2 1 CD 263B 2 80A 2 1 CD 280B 2 100A 4 1 CD 284B 4 25A 4 1 CD 425B 4 40A 4 1 CD 440B 4 63A 4 1 CD 463B 4 80A 4 1 CD 480B* CD 263B 4 100A 4 1 CD 484B*
Medium sensitivity 100mA 2 25A 2 1 CE 225B 2 40A 2 1 CE 240B 2 63A 2 1 CE 263B 2 80A 2 1 CE 280B 2 100A 2 1 CE 284B 4 25A 4 1 CE 425B 4 40A 4 1 CE 440B 4 63A 4 1 CE 463B 4 80A 4 1 CE 480B 4 100A 4 1 CE 484B
Low sensitivity 300mA 2 25A 2 1 CF 225B 2 40A 2 1 CF 240B 2 63A 2 1 CF 263B 2 80A 2 1 CF 280B 2 100A 2 1 CF 284B 4 25A 4 1 CF 425B 4 40A 4 1 CF 440B 4 63A 4 1 CF 463B 2 80A 2 1 CF 480B 2 100A 2 1 CF 484B
Low sensitivity 500mA 2 25A 2 1 CG 225B CE 484B 2 40A 2 1 CG 240B 2 63A 2 1 CG 263B 2 80A 2 1 CG 280B 2 100A 2 1 CG 284B 4 25A 4 1 CG 425B 4 40A 4 1 CG 440B 4 63A 4 1 CG 463B 4 80A 4 1 CG 480B 4 100A 4 1 CG 484B
Terminal cover kit for RCCBs 2I 16 to 63A 10 sets CZ 005 (1 set = 2 covers) for RCCBs 4I 16 to 63A 10 sets CZ 006 for RCCBs 2I 80 to 100A 10 sets CZ 007 for RCCBs 4I 80 to 100A 10 sets CZ 008
Locking kit : MZ 175 16 Combined MCB/RCD (RCBO)
Description Technical data : mechanical life : compact protection devices the units are available with 20 000 operations which provide MCB overcurrent current ratings of 6A, 10A, 16A, 6kA for 6-20A protection and RCCB earth 20A, 25A and 32A. The device 4.5kA for 25-32A leakage protection in a single switches both the phase and unit. neutral conductors. All ratings Type AC have 10mA, 30mA or 100mA Specification earth leakage protection. The Connection capacity ▫ IEC 1009 units feature indicators which rigid conductor 25 ▫ SS480 show whether tripping is due to flexible onductor 16 an overcurrent or earth leakage Protected against transient fault. voltages (lightning, line distur- voltage rating - 110-230V bances,...) and transient currents current rating - 6-32A. (from high capaciti. circuits)
Designation Sensitivity In/A breaking Width in I Pack Cat. ref. Cat. ref. I n capacity 17.5mm qty. type B type C
RCBO 1P+N 10mA 16 6kA 2 1 AC 007G AC 022G terminal only version
30mA 6 6kA 2 1 AD 004G AD 019G
10 6kA 2 1 AD 005G AD 020G
16 6kA 2 1 AD 007G AD 022G AD 022G 20 6kA 2 1 AD 008G AD 023G
25 4.5kA 2 1 AD 009G AD 024G
32 4.5kA 2 1 AD 010G AD 025G
100mA 6 6kA 2 1 AE 019G
10 6kA 2 1 AE 020G
16 6kA 2 1 AE 022G
20 6kA 2 1 AE 023G
25 4.5kA 2 1 AE 024G
32 4.5kA 2 1 AE 025G
17 RCBO electronic
Description Terminal capacities : ▫ compact one module protection 1 module type - 16 rigid ▫ devices which combine the 10 flexible overcurrent functions of an MCB operation temperature : with the earth fault functions of -25°c to +55°C an RCD. A range of senstivity and current ratings are available Features for use in domestic commercial 1 module devices provide a and industrial applications compact solution for installation in consumer units, Invicta TP+N Technical data distribution boards, and din rail specification enclosures. These devices are complies with BSEN61009, 1P & solid neutral. IEC1009 Operating voltage Sensitivity (fixed) 110 - 230 V AC 10 - 30 - 100 mA Flying neutral lead length 700mm
Sensitivity I n Breaking In/A Width in I Pack Cat.ref. Cat. ref. mA capacity 17.5mm qty. type B type C
10mA 6kA 16A 1 1 AC 107 AC 122
30mA 6kA 6A 1 1 AD 104 AD 119 10A 1 1 AD 105 AD 120 16A 1 1 AD 107 AD 122 20A 1 1 AD 108 AD 123 25A 1 1 AD 109 AD 124 32A 1 1 AD 110 AD 125 40A 1 1 AD 111 AD 126 45A 1 1 AD 112 AD 127 50A 1 1 AD 113 AD 128
100mA 6kA 6A 1 1 AE 106Z 10A 1 1 AE 110Z 16A 1 1 AE 116Z AD 110 20A 1 1 AE 120Z 25A 1 1 AE 125Z 32A 1 1 AE 132Z 40A 1 1 AE 140Z 45A 1 1 AE 145Z 50A 1 1 AE 150Z
30mA 10kA 6A 1 1 AD 184 10A 1 1 AD 185 16A 1 1 AD 187 20A 1 1 AD 188 25A 1 1 AD 189 32A 1 1 AD 190 40A 1 1 AD 191
18 Earth leakage relays
Earth leakage relays with relay/core link. - remote test and reset by 3-wire supply contactor/trip separate detection torroids - positive reset required after a link. fault is detected. these units ensure the protection - test button for simulation of a Torroids earth of electrical installations and the fault. circular dia. 35, 70, 105, 140mm leakage protection of persons against - protected against nuisance rectangular 70x175, 115x305, relay direct and indirect contacts. tripping 150x350mm - DC sensitive detection torroid this range of products contain a - output : 1 C/O contact 250V~ Connection capacity set of earth leakage relays, 8A AC1. relay : conforms to IEC 1008 ▫ designed on an electronic basis, - visual display of fault by red flexible 1 to 2.5 ▫ which ensure the monitoring of LED. rigid 1.5 to 4 earth fault currents. When the - supply voltage 220/240V~ fault current rises above the 50/60Hz relay - torroid link selected level, the outputs of the 2 wires, 50m max. product operate depending on Features according to the test and remote reset link the relay selected, it can have selected model 3 wires, 50m max. either fixed or selectivity - adjustment of sensitivity and purposes. time delay (sealable). the relays are linked with detec- - extra positive safety contact tion torroids. 7 separate types (1C/O 250V AC~ 5A AC1). are available, circular and - display of fault current before it rectangular in section. triggers the relay (5% to 75%). - extra output contact (250V Common characteristics 0.1A max.) to enable remote For technical information - positive safety : the relay trips indication of fault currents over see page 44 in the event of a break in the 50% of I n
Designation Characteristics Width in I Pack Cat. 17.5mm qty. ref.
Earth leakage instant trip 4 1 HR 220 relay adjustable sensitivity C/O contact 0.03A/0.1A/0.3A/1A/3A 8A~ AC1 250V~
Earth leakage LED version with 4 1 HR 223 relay optical scale C/O contact adjustable time delay 8A~ AC1 250V~ 0/01s./0.25s./0.35s./0.5s HR 223 adjustable sensitivity positive safety 0.03A/0.1A/0.3A/1A/3A C/O contact 5A~ AC1 250V~ LED version with 4 1 HR 228 optical scale output contact for adjustable time delay remote indication of 0/01s./0.25s./0.35s./0.5s fault current adjustable sensitivity 0.3A/1A/3A/5A/10A
Earth leakage instant trip or time delay 4 1 HR 210 relay standard 0.13 - 0.3 - 1& 3 sec C/O contact adjustable sensitivity 8A~ AC1 0.03A/0.1A/0.3A/1A/3A
19 Earth leakage relays
Characteristics Pack Cat. qty. ref.
Circular section torroid 35mm 1 HR 910 section 7cm2
70mm 1 HR 911 section 38cm2
105mm 1 HR 912 section 87cm2 HR 911
140mm 1 HR 913 section 154cm2
Rectangular section torroid 70 x 175mm 1 HR 920 section 123cm2
115 x 305mm 1 HR 921 section 351cm2
150 x 350mm 1 HR 922 HR 920 section 525cm2
20 BS 1361 HRC fuse carriers and fuses
Description Technical data : protection and control of circuits - fuse carriers suitable for fuses against overloads and short which fully comply with the circuits : dimensional, power loss, fusing - in domestic installations factor, discrimination and time - in commercial and light current characteristics require- industrial electrical distribution ments of BS 1361:1971 systems - short-circuit rating : 16.5kA (i.e. no further consideration of fault levels is necessary) - colour coded ratings - connection capacities : ▫ top : 16 flexible cable + busbar ▫ (16 rigid cables) - specifications : BS 1361:1971
Designation Current Colour Width in I Pack. Cat. rating (Amps) 17.5mm qty. ref.
Fuse carriers 5A - 240V white 1 12 L 113
15A - 240V blue 1 12 L 115
20A - 240V yellow 1 12 L 116
30A - 240V red 1 12 L 118
BS 1361 HRC 5A (23 x 6.35 x 4.8mm) white 50 L 153 cartridge fuses (suitable only for 15A (26 x 10.32 x 6.4mm) blue 50 L 155 L11x carriers) 20A (26 x 10.32 x 6.4mm) yellow 50 L 156
30A (29 x 12.7 x 8mm) red 50 L 158
HRC fuse carriers
Fuse carrier 32 Amps max. - rated breaking capacities; protection and control of circuits 80kA at 415 V a.c. against overloads and 40kA at 250 V d.c. short-circuit : - specification : - in single or three phase IEC 269 subcircuits - for cyindrical cartridge fuses - suitable for fuses which 10.3 x 38mm comply with IEC 269 - rating voltage :415 V a.c. 250 V d.c. - fusing factor : class Q1
Designation description Width in I Pack. Cat. 17.5mm qty. ref.
Fuse carriers 1 phase 1 12 L 501 for cylindrical cartridge fuses 10.3 x 38mm 1 phase + neutral 2 6 L 502 (supplied without fuse) 3 phase 3 4 L 503
3 phase + neutral 4 3 L 504
21 L51 - L58 HRC fuse carriers
Fuse carriers L 51 Fuse carriers L 58 can be padlocked in the off for cylindrical cartridge fuses for cylindrical cartridge fuses position 14 x 51mm 22 x 58mm 50A 690V 125A 690V comply with IEC 947-3 comply with IEC 947-3
Connection capacity : Connection capacity : ▫ ▫ 35 rigid cable 50 rigid cable ▫ ▫ 25 flexible cable 35 flexible cable
Designation description Width in I Pack Cat. 17.5mm qty. ref.
L51 fuse carrier SP 1 phase 1 1/2 10 LR 601
DP 2 phase 3 5 LR 602
3P 3 phase 4 1/2 3 LR 603
3P+N phases + equipped neutral 6 2 LR 604
L58 fuse carrier SP 1 phase 2 6 LR 701 LR 601 DP 2 phase 4 3 LR 702
3P 3 phase 6 2 LR 703
3P+N phases + equipped neutral 8 1 LR 704
LR 703
22 Motor starters
Description Conform to : Options : to ensure localised control and IEC 947-1, IEC947-2 under volt coils : protection of single and three MZ 528N, MZ 529N, phase motors. All motor starters ▫ Note : auxiliary contacts : have thermal and adjustable please consult us for enclosure MZ 520N, MZ 527N magnetic trip. selection alarm contact : MZ 527N Technical data : - adjustable thermal relay - AC3 utilisation category
Connection capacity 2 conductors For technical information ▫ max size 1 to 4 flexible see page 46 ▫ 1.5 to 6 rigid
Designation current standard power rating of 3 phase Width in I Pack Cat. ref. setting motor 50/60Hz (AC3 category) 17.5mm qty. type B 230V (kW) 400V (kW)
Motor starters 0.1 - 0.16A 1 MM 501N
0.16 - 0.24A - 0.06 2 1/2 1 MM 502N
0.24 - 0.4A 0.06 0.09 2 1/2 1 MM 503N
0.4 - 0.6A 0.09 0.12 2 1/2 1 MM 504N
0.6 - 1.0A 0.18 0.25 2 1/2 1 MM 505N
1.0 - 1.6A 0.25 0.55 2 1/2 1 MM 506N MM 501N 1.6 - 2.4A 0.55 0.8 2 1/2 1 MM 507N
2.4 - 4A 0.8 1.5 2 1/2 1 MM 508N
4 - 6A 1.5 2.5 2 1/2 1 MM 509N
6 - 10A 2.5 4 2 1/2 1 MM 510N
10 - 16A 4 7.5 2 1/2 1 MM 511N
16 - 20A 5.5 9 2 1/2 1 MM 512N
20 - 25A 7.5 12.5 2 1/2 1 MM 513N MZ 520N
Auxiliary contacts 1C + 1O 2A - 400V~ 1/2 1 MZ 520N (act as an indicating 3.5A - 230V control device to monitor the ON or OFF position)
Alarm contacts 1C 1A - 400V~ 1 MZ 527N (mounted inside the 2A - 230V motor starter)
Under voltage release 230V~ 50Hz 1 MZ 528N MZ 527N (to prevent automatic restarting of the 400V~ 50Hz 1 MZ 529N controlled device)
Surface mounting enclosure weatherproof IP55 1 MZ 521N removable window w78 x h150 x d95mm
Emergency stop button mounted on surface mounting 1 MZ 530N IP55 enclosure MZ 521 MZ 521N 23 Surge protective devices (SPD)
SPD’s protect elecrical and The range of SPDs is auxiliary contact for remote electronic equipment against separated into 2 types of signalling (R versions only) transients, originating from protection : lightning; switching of Installation and connection : transformers, lighting and 1. main protection - class 2 the main protection SPDs are motors. SPDs with higher discharge installed directly after the main current (Imax 8/20µs), to evacu- incoming MCB These transients can cause pre- ate as much of the transient to mature ageing of equipment, earth as possible. SPDs can be used in any supply down time, or complete system e.g TNCS, TNS, TT destruction of electronic 2. fine protection - class 2 + 3 components and material SPDs with low voltage protec- Options : tion level (Up 1000V), to - replacement cartridges SPDs are strongly recommended cut-down the transient surge as on installations that are exposed low as possible to protect very connected in parrallel to the to transients, to protect sensitive sensitive equipment equipment to be protected and expensive such as TV, video, washing machines, Hi-Fi, Technical data protection is assured in both PC, alarm etc... complies with IEC61643-1 common and/or differential modes The choice of SPD depends on reserve status indicator a number of criteria such as : (R versions) - the exposure of the building to transients - the sensitivity and value of the electrical equipment that requires protection end of life indicator - earthing system (D versions) - level of protection