RP1008-Climatemaster-Residential-Accessories-Geothermal-Heating-And-Cooling-Product

Total Page:16

File Type:pdf, Size:1020Kb

RP1008-Climatemaster-Residential-Accessories-Geothermal-Heating-And-Cooling-Product ACCESSORIES UNIT AND LOOP ACCESSORIES Accessories Table of Contents Accessory Description .......................................................................3 Loop Accessories ................................................................................18 Accessory Compatability ..................................................................4 Extra Large Loop Accessories .....................................................20 Thermostats and Service Tools ......................................................5 Installation Accessories ....................................................................21 AWC99B01 iGate® Connect, Two-Way Geothermal Loop Pipe ...................................................................22 Communicating Thermostat ............................................................6 Geothermal Fittings ...........................................................................23 ATU3203 iGate® Communicating Thermostat ....................7 Socket Fusion Tools............................................................................25 ATP32U03 Thermostat ......................................................................9 Service Tools ..........................................................................................26 ATP32U04 Thermostat ...................................................................11 Service Parts Kit ..................................................................................26 ATA21U01 Thermostat ...................................................................13 Cabinet Samples..................................................................................26 AZ06CAR iGate® ClimaZoneTM Zoning Panel....................14 Filters .........................................................................................................27 iGate® Smart Tank ..............................................................................15 Revision History ..................................................................................28 Unit Accessories ..................................................................................16 2 ClimateMaster: Declare your personal energy independence. ClimateMaster Geothermal Heating and Cooling To further improve comfort and convenience, ClimateMaster offers the following accessories Water-to-Air iGate® Smart Tank Industry’s fi rst Communicating water storage EarthPure® Electronic Air Cleaner tank, allows full-time year-round hot water by ® communicating water temperature to the Trilogy ® ClimateMaster’s EarthPure Polarized Media Q-Mode® unit. The control on the Smart tank Electronic Air Cleaner installs directly into the controls the Titanium electric elements to minimize 2”/1” fi lter rack of your ClimateMaster heat use. The Seamless polybutene tank is designed for pump or air handler. The electronically enhanced a lifetime of highly effi cient use and is impervious media combines elements of both electronic to corrosion. The thick polyurethane foam offers and media air cleaners. It effi ciently removes superior insulation compared to other storage particles down to 0.3 microns and REMOVES tanks. The tough, molded polyethylene exterior ODORS. resists dents, scratches, and salt air. Tranquility® Secondary TM Drain Pan iGate® ClimaZone Zoning Panel The ClimateMaster Secondary This optional panel allows a single Trilogy Drain Pan was designed specifi cally unit to be controlled by muliple thermostats, for Tranquility® Horizontal foot conditioning the home in smaller zones prints. This drain pan matches instead of one large single zone. One unit the unit perfectly for open ceiling accommodates up to 6 zones with a single applications and to meet required panel or up to 12 zones with two panels. mechanical codes. Remote Thermostat Sensor Tranquility® Unit Vibration Isolation Pad Outdoor or Remote Temperature Sensor High density rubber pad for quiet operation. The sound/vibration SecureStart™ Compressor Soft Start Kit isolation pad is ideal for second Single phase compressors typically fl oor, pier and beam construction have starting inrush currents that range and attic installations. from fi ve to seven times their normal running current. The SecureStart™ Tranquility® Unit Stand module is designed to reduce inrush Compliment the ClimateMaster current to the compressor by up to Tranquility® product line with a 75% and prevents lights dimming when matching unit stand. This stand the compressor starts up. is ideal for areas that must have raised equipment to meet required mechanical codes. Water-to-Water Auxiliary/Electric Heater Anti-Scald Valve Internally mounted in vertical cabinets. Anti-scald valve be used in DHW systems where Externally mounted on horizontal HWG setpoint is 150°F cabinets. Sizes 15-20 kW AGM*A and 4-20 kW AGM*C include internal Accessory Pump Slaving Module circuit breaker. ETL listed. Circuit fusing per UL/NEC. Wiring harness Allows a single fl ow controller to be connections included in residential units. controlled by 2 different units. Eliminates additional fi eld wiring and extra relays. Flow Controller Small Compact, proven design, easy to mount, urethane foam insulated to prevent condensation, includes factory supplied full fl ow service valves for easy loop charging, Uses double o-ring adaptor fi ttings for unit and loop connections. Gray polystyrene cabinet with black pumps. Composite 3-way valves. 230VAC pump(s). 3 Residential Products Technical Guide Accessories Accessory Compatibility Water-to- Packaged Split Water Tranquility® Trilogy® Digital Tranquility® Tranquility® Digital Tranquility® Accessories QE TE TZ TS TES, TEP TAH, TAC TBW, TCW iGate® Smart Tank X iGate® ClimaZoneTM X ® AWC iGate Connect X thermostat ATC thermostat/ ACD XX X X service tool ATP/ATA Thermostats XX X X X EarthPure® Polarized Media Electronic Air XX X X X Cleaner Secondary Drain Pan XX X ® Tranquility Unit Vibration XXXX X Isolation Pad Tranquility® Unit Stand XXXX X Auxiliary Electric Heater XXXX X X Remote/Outdoor XXXX X X Temperature Sensor ClimaDry X Potentiometer Kit Anti Scald Valve XX X X X X Accessory Pump Slaving XX Module Secure Start Compressor Soft XX X X X X Start Kit Remote Mount HWG X (Desuperheater) Kit 4 ClimateMaster: Declare your personal energy independence. ClimateMaster Geothermal Heating and Cooling Thermostats and Service Tools Thermostats—Communicating AWC99B01 ATC32U03 Internet-connected, Digital, communicating, programmable, Digital, communicating, programmable, 3-stage heat, variable stage heat – cool. Confi gure, monitor and diagnose 2-stage cool. Confi gure, monitor and diagnose system from system from thermostat or dealer portal on internet. thermostat. ONLY USED WITH TRILOGY®. Service Tools—Communicating ACDU02 ASVCTOOL01 Confi guration diagnostic tool. For use when communicating ® ® thermostat is not used. For Trilogy units only. Connect to the Trilogy 's EXM board to confi gure, diagnose and update Trilogy® software. Thermostats—Non-Communicating ATP32U03/ATP32U04 ATA22U01 Programmable, digital, 3 stage heat, 2 stage cool, auxiliary, Non-programmable 2 stage heat, 2 stage cool; aux, fault LED. Use 04 with ClimaDry® units. emergency, fault LED 5 Residential Products Technical Guide Accessories AWC99B01 iGate® Connect, Two-Way Communicating Thermostat Variable Stage Heating and Cooling Programmable • Information is remotely available (if you wish) to your dealer through a dealer portal for remote troubleshooting and diagnosis • Secure internet connection keeps your information private • Easy-to-use, high-resolution color display and intuitive interface • Key features: –Precision +/-1°F (0.5°C) temperature control –Vacation programming –Seven-day programming –Humidity sensing –Intelligent algorithms that adapt to your home EXM Control Board and preferences Connections for thermostat R terminals to equipment: –Fan control A+ –Hot water control B- • Dealer can receive alerts regarding maintenance, ineffi cient C operations or faults • Alerts and warning data are viewable from the thermostat and homeowner/dealer portal • Real time system performance is stored, which increases the Remote Sensor 1 accuracy of diagnosing issues and results in faster repairs • "Service Needed" alert displays dealer name, phone Remote Sensor 2 number, model unit/serial number, fault condition and possible causes iGate™ Connect Thermostat • Secure internet portal keeps your information private • Accessible with Android and iPhone mobile app Controls: R2- R2+ R1- R1+ B- A+ Gnd 24v • Heat pump control • Auxiliary heat • Programmable fan control • Auto-changeover • Humidity control • Intelligent setback recovery Application: • On-screen contractor information Internet connected, digital, two-way communicating, • Confi gurable min/max set temperature programmable, variable stage heat-cool. Confi gure, monitor • Switch between Farenheit and Celsius and diagnose system from thermostat or dealer portal on • Confi gurable upstaging and downstaging internet. The thermostat is only compatible with Trilogy® units. • Wireless protocol: B/G/N • Wi-Fi security encryption Features: • Encryption communication over internet Web-Enabled Home Thermostat • 365-day scheduling/7-day programming • Communicates personal settings and reminders through Specifi cations: the iGate® communication system • Easy to use, full color, high resolution interface Temperature Settings: • Receives notifi cation for routine maintenance • Heat: 55 to 80°F (12 to 27°C) • Sleek, intuitive button control • Cool: 65 to 95°F (18 to 35°C) • Secure internet
Recommended publications
  • HVAC TERMINOLOGY.Pdf
    HVAC TERMINOLOGY Abatement Reduction or removal of a contaminant. Absolute Humidity It is the ratio of the mass of water vaporto the unit volume of moist air represented in grams per cubic foot (g/ft3). Absolute Zero Temperature at which all molecular motion ceases (-460 F. and -273 C.). Absorption Refrigerator Refrigerator which creates low temperature by using the cooling effect formed when a refrigerant is absorbed by chemical substance. ACCA Air Conditioning Contractors of America - a leading HVAC/R Association. Acceptable indoor air quality Indoor air that does not contain harmful concentrations of contaminants; air with which at least 80% of building occupants do not express dissatisfaction. Accumulator Storage tank which receives liquid refrigerant from evaporator and prevents it from flowing into suction line before vaporizing. Tank on the suction side of a system that holds excess refrigerant to prevent slugging the compressor with liquid. ACH Air Changes Per Hour. The number of times that air in a house is completely replaced with outdoor air in one hour. Acid Condition In System Condition in which refrigerant or oil in system is mixed with fluids that are acid in nature. ACR Tubing Tubing used in air conditioning and refrigeration. Ends are sealed to keep tubing clean and dry. Activated Carbon Specially processed carbon used as a filter drier ; commonly used to clean air. Actuator That portion of a regulating valve which converts mechanical fluid, thermal energy or insulation energy into mechanical motion to open or close the valve seats. Adiabatic Compression Compressing refrigerant gas without removing or adding heat. Adjustable Grille A grille with linear blades which can be adjusted to vary the direction of the discharged air.
    [Show full text]
  • Dr. Ben's Solar Hot Water Systems Install
    Dr. Ben’s Solar Hot Water Systems Installation Manual By Ben Gravely, PhD Holocene Technologies 1241 Wicker Drive Raleigh, NC 27604 (c) 2012 2 Table of Contents 1. Planning the Installation 1.1 Site Analysis 1.2 Collector Tilt 1.3 Materials 2. Tank Installation 3. Collector Installation and Controls 3.1 Frame and Collector Mounting 3.2 Collector Piping 3.3 Pipe Insulation 3.4 Solar Controls and Wiring 3.5 Collector System Startup 4. Domestic Hot Water 4.1 Piping 4.2 Re-circulator DHW Controls 4.3 DHW System Startup 5. Space Heating 5.1 Forced Air Systems 5.1.1 Solar Controls for Gas/Oil Furnaces 5.1.2 Solar Controls for Heat Pumps (Reverse on Cooling) 5.1.3 Solar Controls for Heat Pumps (Reverse on Heating) 5.1.4 Space Heating Startup and Test 5.2 Radiant Slab Systems 5.3 Radiant Baseboard Systems 6. Pool/Spa 6.1 Pool/Spa Piping 6.2 Pool/Spa Controls 6.3 Pool Startup 7. Manually Fired Wood/Coal Boilers 7.1 Boiler Installation 7.2 Boiler Piping 7.3 Boiler Controls 8. Troubleshooting 8.1 Collector System 8.2 Differential (delta-T) Controllers 8.3 Space Heating System 8.4 Pumps About the Author Holocene Technologies © 2012 3 1. Planning the Installation This manual was written to provide a straight forward procedure for the installation of solar hot water systems. As with any project, a few minutes of planning will save hours of fixing. 1.1 Site Analysis Measure the angle of the collector mounting surface from south with a compass.
    [Show full text]
  • Maintenance Items N475HM
    02-Jul-2020 Maintenance Items N475HM Make & Model (Serial) Operator Date Hours Landings BEECHCRAFT HAWKER 800XP (258451) Business Jet Access 01-Jul-2020 3997.30 2744 Major Components Component Model (Serial) Hours Cycles Engine 1 TFE731-5BR-1H (P-107444) 3840.90 2656.00 Engine 2 TFE731-5BR-1H (P-107443) 3890.20 2680.00 APU 0 GTCP36-150 (P-522) 3984.00 0.00 ATA / Type / Group Description Compliance Intervals Tolerance TSN/TSO Next Due Remaining 01 1001 INSPECT AIRCRAFT KEY STORAGE UNIT FOR LOCATION AND SECURITY 08-JUN-2020 M: 6 31-DEC-2020 M: 5 D: 29 Airframe Work Order H: 3990.80 INSPECTION Number L: 2741 #2263 June 2020 04 0010 AIRCRAFT PAINT 29-NOV-1999 Airframe H: 0.00 INSPECTION #299 04 0015 AIRCRAFT INTERIOR 29-NOV-1999 Airframe H: 0.00 INSPECTION #1532 04 0500 LUBRICATE ALL AIRCRAFT LOCKS TO INCLUDE MAIN ENTRANCE DOOR AND SERVICE 17-MAR-2020 M: 4 M: 1 31-JUL-2020 M: 0 D: 29 Airframe PANELS H: 3975.50 INSPECTION Work Order Man Hours L: 2726 #483 Number July 2020 0.50 04 100 AIRCRAFT REGISTRATION-FAR 47.40 29-NOV-2019 M: 36 M: 4 30-NOV-2022 M: 28 D: 28 Airframe H: 3962.70 INSPECTION L: 2714 #1803 04 200 REDUCED VERTICAL SEPARATION MINIMUM (RVSM) MONITORING REQUIREMENTS LAST 21-OCT-2019 M: 24 21-OCT-2021 M: 15 D: 19 Airframe FLIGHT OVER AGHME H: 3883.60 INSPECTION L: 2669 #1593 05 0001 PRE-FLIGHT INSPECTION 29-NOV-1999 Airframe H: 0.00 INSPECTION #1675 Maintenance Items Copyright © 2020 Flightdocs, Inc.
    [Show full text]
  • (12) United States Patent (10) Patent No.: US 9,267,713 B2 Zamir (45) Date of Patent: Feb
    US009267713B2 (12) United States Patent (10) Patent No.: US 9,267,713 B2 Zamir (45) Date of Patent: Feb. 23, 2016 (54) TEMPERATURE CONTROL SYSTEM USPC ......................................... 62/235.1; 165/48.2 See application file for complete search history. (75) Inventor: Ofri Zamir, Hogla (IL) (73) Assignee: DZSOLAR LTD, Richmond (GB) (56) References Cited (*) Notice: Subject to any disclaimer, the term of this U.S. PATENT DOCUMENTS patent is extended or adjusted under 35 4.256,475 A 3, 1981 Schafer ........................ 62/235.1 U.S.C. 154(b) by 821 days. 4,285,208 A * 8/1981 Takeshita et al. ............... 62/141 5,177,977 A 1/1993 Larsen (21) Appl. No.: 13/502.923 5,261,251 A * 1 1/1993 Galiyano ..................... 62,176.6 (Continued) (22) PCT Filed: Oct. 20, 2010 FOREIGN PATENT DOCUMENTS (86). PCT No.: PCT/L2O1O/OOO863 AU 2011 100888 A4 2, 2012 S371 (c)(1), CN 26795.62 Y 2, 2005 (2), (4) Date: Apr. 19, 2012 (Continued) (87) PCT Pub. No.: WO2011/048594 OTHER PUBLICATIONS PCT Pub. Date: Apr. 28, 2011 The International Search Report for International Application No. (65) Prior Publication Data PCT/IL2010/000863, three pages, mailed May 12, 2011. US 2012/0204587 A1 Aug. 16, 2012 O O Primary Examiner — Ljiljana Ciric Related U.S. Application Data Assistant Examiner — Alexis Cox (60) Provisional application No. 61/253,573, filed on Oct. (74) Attorney, Agent, or Firm — Vorys, Sater, Seymour & 21, 2009. Pease LLP (51) Int. Cl. F25B 27/00 (2006.01) (57) ABSTRACT F25B I3/00 (2006.01) A temperature control system, including a closed refrigerant (52) U.S.
    [Show full text]
  • Do-It-Yourself HVAC Apprentice Contest Basic Guidelines for Planning an Apprentice Contest
    PHCC Educational Foundation Do-It-Yourself HVAC Apprentice Contest Basic Guidelines for Planning an Apprentice Contest 1. Find volunteers! Members, teachers, technicians and inspectors all make good volunteers. 2. Designate a chairman or coordinator to run the contest. The role of chairman or coordinator can be done by anyone who is willing to volunteer and dedicate the time it takes to plan and administer the contest. He or she should have some HVAC background as well as the ability to answer technical questions about the contest. The chairman/coordinator is responsible for delegating all necessary job tasks. His/her decisions are final. Normally, the chairman/coordinator is the state or local apprenticeship committee chairman or an instructor at an apprentice school. 3. Set up a timeline or schedule of events. 4. Design the test and/or contest you will use. A sample contest has been provided at the end of this book. 5. Make a list of contest rules for the apprentices to follow. Provide this information with the registration form. 6. Make an agenda for the apprentices to follow. Include registration deadlines, time to arrive at the contest site and time of the awards presentation. 7. Find students to compete. Ideally, they should be PHCC apprentices and/or SkillsUSA students. You can have as few as three and as many as you feel you can handle. 8. Find a location for the contest. Some suggestions include outside under a tent, inside an exhibition hall, in a member’s shop or at the apprentice school. If you use an exhibition hall, please note that you may have to obtain a permit from the local fire marshal.
    [Show full text]
  • About Wiring Color
    About Wiring Color There is no official industry standard for wiring colors. However, the majority of manufacturers follow the common practices for installation. The following information is strictly for reference. Please be advised that the technician who did the previous installation of the thermostat may not incorporate conventional color coding for various reasons. Red for the R terminal. The R terminal is the power. This comes from the transformer usually located in the air handler for split systems but you may find the transformer in the condensing unit. For this reason, we advise turning off the power before adjusting the thermostat's wiring. Red for the RH terminal. RH – The RH terminal is designated for the power for heating when two transformers are used. See RC below for an explanation for the cooling. It should be noted that a jumper can be installed between RC and RH for a heating and cooling system equipped with a single transformer. It should be noted that a jumper wire can be installed between RC and RH for a heating and cooling system equipped with a single transformer. Red for the RC terminal. The RC terminal is designated to the cooling power source. Some HVAC systems consist of two transformers, one for cooling and the other for heating. In this case the power from the transformer in the air conditioning system would go to the thermostat terminal RC. It should be noted that a jumper wire can be installed between RC and RH for a heating and cooling system equipped with a single transformer.
    [Show full text]
  • Iii I 1 111.11111 Ii 111111
    THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS 345 E. 47th St., New York, N.Y. 10017 , k97-AA-30 kr The Society shall not be responsible for statements or opinions achrancedin papers or cricussion at meetings of the Society or of Its Divisions or. Sections, or printed In its publications. Discussion is printed only it the paper is published in'an ASME Journal. Authorization to photocopy , , material for Internal or personal use under circumstance not falling within the fair use provisions's% the Copyright Act Is granted by ASME to libraries and other users registered with the Copyright Clearance Center (CCC)Transactional Reporting Service provided that the base fee of $OSO , per page is paid directly to the CCC. 27 Congress Street. Salem MA 01970. Requests for special permission or bulk reproduction shotdd be addressed to the ASME Technical Pubishing Department Copyright *1997 by ASME All Rights Reserved . Printed in U.S.A Heat Exchanger Design And System Balance Of Downloaded from http://asmedigitalcollection.asme.org/GT/proceedings-pdf/TA1997/78675/V001T13A006/4460073/v001t13a006-97-aa-030.pdf by guest on 01 October 2021 An Air Source Heat Pump/Chiller Using Brazed Plate Heat Exchangers. III I 1 111.11111 II 111111 By Changiz Tolouee (M.Sc), Member of International Institute of Refrigeration, Member of Australian Institute of Refrigeration, Air Conditioning and Heating. ABSTRACT Air Source heat pump/chiller is used to provide chilled water for cooling and hot water for heating purposes. This is one investment for both applications with no requirement for boiler and fuel with the advantage of heat pump efficiency.
    [Show full text]
  • Console Water Source Heat Pumps R-410A Models MHC Standard Range & MHW Geothermal Range Flat Top & Slope Top – Unit Sizes 007 – 018
    Installation & Maintenance Data IM 985-2 Group: WSHP Part Number: 669479302 Date: November 2011 Console Water Source Heat Pumps R-410A Models MHC Standard Range & MHW Geothermal Range Flat Top & Slope Top – Unit Sizes 007 – 018 Slope Top Unit Flat Top Unit ® ©2011 McQuay International Contents Model Nomenclature ...........................................................3 Start-up ...............................................................................25 Receiving and Storage ........................................................4 Cooling or Heating – Manual Operation ........................25 Pre-Installation.....................................................................4 Additional Accessories .....................................................25 General ...........................................................................25 Unit Installation (Recommended) ......................................5 Alternate Unit Installation ..................................................7 Wall-Mounted Programmable Electronic Thermostat (Using Provided Brackets) ................................................7 (P/N 668811301) ............................................................... 25 Non-Programmable Electronic Thermostat ...................26 Piping ....................................................................................8 (P/N 668811201) .............................................................26 Water Connections ..............................................................9 Programmable Electronic
    [Show full text]
  • Heating, Ventilation, Air-Conditioning, and Refrigeration. Occupational Competency Analysis Profile. INSTITUTION Ohio State Univ., Columbus
    DOCUMENT RESUME ED 488 875 CE 070 293 TITLE Heating, Ventilation, Air-Conditioning, and Refrigeration. Occupational Competency Analysis Profile. INSTITUTION Ohio State Univ., Columbus. Vocational Instructional Materials Lab. SPONS AGENCY Ohio State Dept. of Education, Columbus. Div. of Vocational and Adult Education. PUB DATE 95 NOTE 80p.; For the 1992 edition, see ED 345 074. For other related profilos, see CE 070 281-294. AVAILABLE FROMVocational Instructional Materials Lab, Center on Education and Training for Employment, 1900 Kenny Road, Columbus, OH 43210-1090 (order no. OCAP-07R: $10). PUB TYPE Guides - Classroom Use - Teaching Guides (For Teacher) (052) EDRS PRICE MF01/PC04 Plus Postage. DESCRIPTORS Air Conditioning; Air Conditioning Equipment; Behavioral Objectives; Career Development; *Competence; Competency Based Education; *Employment Potential; Entry Workers; *Heating; *Job Skills; *Occupational Information; Postsecondary Education; *Refrigeration; Refrigeration Mechanics; Secondary Education; Ventilation IDENTIFIERS DACUM Process; Ohio ABSTRACT This Occupational Competency Analysis Profile (OCAP) contains a competency list verified by expert workers and developed through a modified DACUM (Developing a Curriculum) involving business, industry, labor, and community agency representatives from This OCAP identifies the occupational, academic, and employability skills (competencies) needed to enter building climate control occupations. The competencies are clustered into 12 units that cover the following topics: fundamental concepts
    [Show full text]
  • Air-Source Heat Pumps
    YOUR GUIDE TO Air-Source Heat Pumps AIR-SOURCE HEAT PUMPS: Four Reasons to Switch 1 2 3 4 LOWER GREENHOUSE COST ALL-IN-ONE VERSATILE GAS EMISSIONS COMPETITIVE COMFORT Air-source heat pumps are efficient heating and cooling systems that can keep your home at a comfortable temperature all year round. Clean Energy Lives Here MASSCEC.COM/GOCLEAN Ⓡ TABLE OF CONTENTS Air-Source Heat Pumps (ASHP) Technology Overview 3 Are ASHPs a Good Fit for My Home? 8 Case Studies 9 Benefits of ASHPs 10 Costs 11 Incentives & Financing 12 Efficiency First 13 Making the Switch 14 How Can I Prepare for an ASHP Installation? 15 Questions to Ask Your Installer 17 Getting the Most From Your New System 22 2 Air-Source Heat Pumps (ASHP) Technology Overview Air-Source Heat Pumps are heating and cooling systems that move heat into a home in the winter and draw heat out of the home in the summer. Instead of burning fossil fuels, they operate on the same principle as your refrigerator: using a refrigerant cycle, powered by electricity, to move heat and to keep your home at a comfortable temperature year round. They are much more efficient than electric resistance (electric baseboard) heating and also provide highly efficient air conditioning. Outdoor Unit Indoor Unit Air-source heat pump systems feature an outdoor unit (containing a compressor, reversing valve, heat exchanger and expansion device) connected to one or more indoor units by small refrigerant piping. The refrigerant is a substance with properties that enable it to easily absorb and release heat.
    [Show full text]
  • Technology Review CSU DECARBONIZATION FRAMEWORK TASK 4: TECHNOLOGY REVIEW TABLE of CONTENTS SECTION 4.1: Introduction
    CSU Office of the Chancellor CSU Decarbonization Framework: Technology Review CSU DECARBONIZATION FRAMEWORK TASK 4: TECHNOLOGY REVIEW TABLE OF CONTENTS SECTION 4.1: Introduction ........................................................................................................................ 3 SECTION 4.2: Space Heating Technologies .............................................................................................. 4 4.2.1 Heat Pump Overview .................................................................................................................. 6 4.2.2 Hydronic Heat Pumps ................................................................................................................. 7 Air-to-Water Heat Pump (AWHP)............................................................................................................ 7 Water-to-Water Heat Pump (WWHP) .................................................................................................... 13 4.2.3 Non-Hydronic Heat Pumps ....................................................................................................... 21 Water source heat pump (WSHP)......................................................................................................... 21 Air-to-Air Heat Pump ............................................................................................................................ 25 Variable Refrigerant Flow (VRF/VRV) .................................................................................................... 27
    [Show full text]
  • Caution Caution Warning
    XPG20 Corp. 0907−L3 Service Literature XPG20 SERIES UNITS The XPG20−036 is a high efficiency residential split−system heat pump unit, which features a solar assisted DC motor, two−step scroll compressor and HFC−410A refrigerant. The XPG20 is designed for use with an expansion valve only (approved for use with HFC−410A) in the indoor unit. This manual is divided into sections which discuss the major components, refrigerant system, charging procedure, maintenance and operation sequence. CAUTION Physical contact with metal edges and corners while applying excessive force or rapid motion can result in personal injury. Be aware of, and use caution when working nearby these areas during installation or while servicing this equipment. CAUTION To prevent personal injury, or damage to panels, unit or structure, be sure to observe the following: While installing or servicing this unit, carefully stow all removed panels out of the way, so that the panels will not cause injury to personnel, nor cause damage to objects or structures nearby, nor will the panels be subjected to damage (e.g., being bent or scratched). While handling or stowing the panels, consider any weather conditions, especially windy conditions, that may cause panels to be blown around and bat- tered. DANGER Shock Hazard Remove all power at disconnect before WARNING removing access panel. Improper installation, adjustment, alteration, service XPG20 units use single-pole contac- or maintenance can cause personal injury, loss of tors. Potential exists for electrical life, or damage to property. shock resulting in injury or death. Line voltage exists at all components Installation and service must be performed by a (even when unit is not in operation).
    [Show full text]