Humidity Sensing Fan Read and Save These

Total Page:16

File Type:pdf, Size:1020Kb

Humidity Sensing Fan Read and Save These MODELS QTXE110S • QTXE110S2 To register this product visit: Page 1 HUMIDITY SENSING FAN www.broan.com READ AND SAVE THESE INSTRUCTIONS WARNING OPERATION TO REDUCE THE RISK OF FIRE, ELEC- The humidity control and fan can be op- TIMER ADJUSTMENT TRIC SHOCK, OR INJURY TO PERSONS, erated separately. Use a 1 or 2-function This humidity-sensing fan has a timer. It is OBSERVE THE FOLLOWING: wall control. Do not use a dimmer switch user-adjustable from 5 to 60 minutes and is 1. Use this unit only in the manner intended to operate the humidity control or light. factory-set at 20 minutes. The timer controls by the manufacturer. If you have questions, See “Connect Wiring” for details. how long the fan remains on (a) after rise contact the manufacturer at the address or SENSOR OPERATION in humidity and (b) humidity level are both below the user-adjustable “HUMIDITY” telephone number listed in the warranty. This humidity-sensing fan responds to: (a) 2. Before servicing or cleaning unit, switch setting or after being energized by cycling rapid to moderate humidity increases and power switch. power off at service panel and lock the ser- (b) humidity above a 50%-80% relative vice disconnecting means to prevent power humidity (RH) set-point. (a) and (b) are To adjust the timer: from being switched on accidentally. When set with “HUMIDITY” adjustment. Fan may 1. Disconnect power at electrical service the service disconnecting means cannot be occasionally turn on when environmental panel. locked, securely fasten a prominent warning conditions change. If the fan continuously 2. Through the grille, locate the “MINUTES” device, such as a tag, to the service panel. responds to changing environmental con- screwdriver slot. 3. Installation work and electrical wiring must be ditions, “HUMIDITY” adjustment may be 3. Using a small, flat-blade screwdriver, done by a qualified person(s) in accordance required (see section below). carefully rotate “MINUTES” adjustment with all applicable codes and standards, to desired setting (5 to 60 minutes). including fire-rated construction codes and STATUS INDICATOR 4. Check operation by cycling power switch standards. This indicator can only be seen by looking as instructed under “MANUAL ON WITH directly at it. Normal mode is 5-seconds on 4. Sufficient air is needed for proper combus- TIMED OFF” or by turning on a humidity and off. If it blinks rapidly for 5-seconds and tion and exhausting of gases through the source until fan turns on. flue (chimney) of fuel burning equipment to then off, check sensor connections on grille prevent backdrafting. Follow the heating equip- and fan housing. 5. Check timer setting with watch or clock ment manufacturer’s guideline and safety after turning humidity source off if it was MANUAL ON WITH TIMED OFF standards such as those published by the turned on it Step 4. National Fire Protection Association (NFPA), For odor or vapor control, the fan can be 6. Repeat above steps if necessary. and the American Society for Heating, Re- energized by cycling its wall-mounted switch frigeration and Air Conditioning Engineers if one is installed. Once the fan has been (ASHRAE), and the local code authorities. turned on in this manner, it will remain on 5. When cutting or drilling into wall or ceiling, do for the set “MINUTES” period. not damage electrical wiring and other hidden To manually energize the fan: CLEANING & utilities. 1. Go to Step 2 if switch is already on; 6. Ducted fans must always be vented to the otherwise, turn switch on for more than MAINTENANCE outdoors. 1 second. 2. Switch off for less than 1 second. 7. Acceptable for use over a tub or shower when For quiet and efficient operation, long life, connected to a GFCI (Ground Fault Circuit 3. Switch back on and fan will turn on. and attractive appearance - lower or remove Interrupter) - protected branch circuit. HUMIDITY ADJUSTMENT grille and vacuum interior of unit with the 8. This unit must be grounded. “HUMIDITY” has been factory set for most dusting brush attachment. shower applications. If the fan is in a tub The motor is permanently lubricated and area or is used for dampness control, the never needs oiling. If the motor bearings CAUTION “HUMIDITY” may need to be decreased are making excessive or unusual noises, toward 50% RH. If the control is responding replace the motor/blower wheel assembly. 1. For general ventilating use only. Do not use too often to changing environmental condi- SENSOR CLEANING to exhaust hazardous or explosive materials tions, adjustment toward 80% RH may be and vapors. The humidity sensor is mounted in the grille. required. To adjust the “HUMIDITY”: The sensor will operate most reliably when 2. This product is designed for installation in flat 1. Turn power off at electrical service cleaned occasionally as follows: ceilings only. DO NOT MOUNT THIS PROD- panel. 1. Disconnect power at service entrance. UCT IN A WALL. 2. Through the grille, locate the “HUMIDITY” 3. To avoid motor bearing damage and noisy 2. Remove the grille. Use a dry dustcloth, screwdriver slot. clean toothbrush, or lightly vacuum to and/or unbalanced impellers, keep drywall 3. Using a small, flat-blade screwdriver, spray, construction dust, etc. off power unit. clean sensor and grille. DO NOT USE carefully rotate “HUMIDITY” adjustment ABRASIVE CLOTH, STEEL WOOL 4. Please read specification label on product for toward 50 or 80. PADS, OR SCOURING POWDERS. further information and requirements. 4. Turn power on and check operation by 3. DO NOT USE cleaning sprays, solvents, turning on shower or other humidity or water on or near the sensor! Installer: Leave this manual source until fan turns on. with the homeowner. 5. Repeat above steps if necessary. MODELS QTXE110S • QTXE110S2 Page 2 • Locate unit above (GFCI protected circuit required) or TYPICAL INSTALLATIONS within 5 feet of shower head. • Locate unit away from heating or cooling sources which can affect humidity levels. • Do not locate near window. Unit may respond to the outdoor humidity level. • Unit must be installed in ceiling to properly sense moisture. • Locate unit only on flat ceilings up to 12 feet high for proper sensing. • The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct rout- Housing mounted to Housing mounted anywhere be- ing possible for best performance, and avoid installing I-joists. tween I-joists using hanger bars. the fan with smaller ducts than recommended. Insula- tion around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow. 2. Plan the wiring. • Plan to supply the unit with proper line voltage and appropriate power cable. Power cable should be routed to the switch box first and then to the unit (See “CONNECT WIRING” on page 3). • Do not operate this unit with a speed control. Damage to the sensor unit will result. Housing mounted to joists. Housing mounted anywhere be- tween joists using hanger bars. INSTALL HOUSING & DUCT 1a. Mount housing to joist or I-joist. Use a pliers to Housing mounted anywhere Housing mounted anywhere be- bend housing TABS between trusses using hanger tween trusses using hanger bars. TABS out to 900. Hold hous- bars. ing in place so that the hous- ing tabs con- PLAN THE INSTALLATION tact the bottom SPACER of the joist. (use for mounting to I-Joist) 1. Choose the The housing INSULATION* ROOF CAP* mounts with installation (Place around and (with built-in location. over Fan Housing.) damper) four (4) screws FAN or nails. Screw HOUSING or nail housing POWER Keep duct The location of CABLE* runs short. to joist through your humidity lowest holes in sensing fan is each mount- Seal gaps ing flange, very important. around Housing. I-JOIST Use the follow- OR then through 6-IN. ROUND highest holes. ing guidelines DUCT* Seal duct NOTE: Mounting to I-JOIST (shown) requires use of for best opera- joints with 6-IN. WALL CAP* *Purchase (with built-in SPACERS (included) between the highest hole of each tion: separately. tape. ROUND ELBOWS* damper) mounting flange and the I-joist. OR MODELS QTXE110S • QTXE110S2 Page 3 1b. Mount housing anywhere between 2. Attach damper/ trusses, joists, or I-joists using hanger duct connector. bars. Snap damper / duct con- nector onto housing. Make Sliding hanger bars are provided to allow for accurate posi- sure connector is flush tioning of housing anywhere between framing. They can be with top of housing and used on all types of framing (I-joist, standard joist, and truss damper flap falls closed. construction) and span up to 24”. TAB SCREWS (4) 3. Install 6-inch round duc- twork. Connect 6-inch round ductwork to damper / duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork con- nections to make them secure and air tight. MOUNTING HANGER CHANNEL (2) BAR (4) Attach the MOUNTING CHANNELS to the housing using CONNECT WIRING the SCREWS supplied. Make sure TABS face “up” as shown. Use the set of channel mounting holes (marked “STD”) to WIRING OPTION #1 - Allows fan to operate in automatic mode or manual mount the housing flush with the bottom of the drywall. Use mode (for odor control) by cycling ON/OFF switch. the other set of holes (not marked) to mount the housing ON / OFF SWITCH flush with the top of the drywall. (PURCHASE SEPARATELY) ORG BLK WHT FAN ON / OFF SWITCH BLK HOLE FOR OPTIONAL SCREW (2) BRN HUMIDITY WHT * CONTROL SCREW MOUNTING (4) BLK 120 VAC WHT WHT WHT LINE IN GRD GRD SWITCH BOX UNIT WIRING OPTION #2 - Fan can be turned ON, OFF, or set to operate automati- cally.
Recommended publications
  • The Gold Standard in Fan Heaters
    WALL FAN HEATER ARWF SERIES THE GOLD STANDARD IN FAN HEATERS The PULSAIR™ is extremely popular for many reasons. First, it can be recessed or surface mounted with a surface adapter (optional). In addition, it can be mounted vertically or horizontally, directing the air flow upward or downward and to the right or to the left, respectively. Last, the slim-line PULSAIR™ can be recessed into W W W W Y Y Y A A A A T T a wall thickness of 2 in. to 3 in. While it’s a winning heating solu- T R R R R N N N R R R R A A A LIFETIME A A A A R R R N N N N R R R on element T T T T A A A tion for the hallway and bathroom, it can also be installed in other Y Y Y Y W W W W W W parts of the house, such as the office or in commercial buildings. W Y Y Y Y A A A A T T T T R R R R N N N R N Its nichrome element provides instant heat. Available from 500 W R A R A R A A A A R A R A R R N N N N 2YEAR R 3YEAR R 5YEAR R 5YEAR R T A T A T A T to 2000 W, and from 120 V to 277 V, the PULSAIR™ is recognized Y Y Y Y A W W W W W W W W and recommended by those in the know.
    [Show full text]
  • Single Pole Humidity Sensor and Fan Controller Cat
    Single Pole Humidity Sensor and Fan Controller Cat. Nos. IPHS5 - INDOOR USE ONLY 120VAC, 60Hz - Single Pole Only Incandescent: 600W - MLV/Fluorescent: 400VA - LED/CFL: 150W - Fan: 1/6Hp WARNINGS CAUTIONS • TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER • Clean outer surface gently with damp cloth only. DO NOT use soaps or cleaning OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING! liquids. • TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to • No user serviceable components. DO NOT attempt to service or repair. control a receptacle, or a load in excess of the specified rating. • Use this device WITH COPPER CLAD WIRE ONLY. • To be installed and/or used in accordance with electrical codes and regulations. • If you are not sure about any part of these instructions, consult an electrician. DI-000-IPHS5-02B INSTALLATION ENGLISH Features Location You Will Need: The humidity sensor and fan controller senses the humidity of your bathroom • Slotted/Phillips screwdriver • For bathroom applications the device should be placed and turns your bath fan or fan/light on when the humidity gets too high, • Pencil reducing condensation in your bathroom and increasing ventilation when used at a level to detect steam. Placing the detector directly in other household spaces. above a heater or near drafts is not recommended. • Electrical tape • Compatible with Incandescent, LED, CFL and Fluorescent loads when • NOTE: DO NOT use to control a fan/light combination • Cutters used with combination fan and light fixtures. where the fan/light is the only means of illumination.
    [Show full text]
  • Delta Fan Heater
    PAGE 1/2 DELTA FAN HEATER DELTA is a robust, reliable fan heater that is designed for use in TECHNICAL DATA areas that require a little more of materials and performance, for Voltage range: instance construction sites and ships. • 1x110V to 3x690V + PE DELTA is also used for more permanent installations such as in- Frequenzy, can be used at: dustrial buildings and warehouses, workshops, factories or ga- • 50 Hz and 60 Hz rages, as it can go from transportable to permanent fixture with Degree of protection for electrical components: a simple wall-bracket. • TP1: 3-9kW = IP44 • TP2: 15-21kW = IP34 It comes with an integrated 0-40°C room thermostat that en- Temperature control: sures optimal operation and minimizes energy consumption, as • TP1: Combi termostat with adjustable room thermostat 0-40°C well as a thermal cut-out to protect against overheating. The + thermal cut-out fan heater works without standby and does not use unneces- • TP2: Adjustable room thermostat 0-40°C + thermal cut-out sary power. Level regulation: • Manually operated 5-level change-over switch that regulates DELTA is built with internal casing in the heating chamber, which air speed and heating effect. Moreover, all types can be sup- ensures that the entire flow of air passes over the heating ele- plied with a 24-hour timer. A DELTA fan heater with timer ments. This eliminates problems with varying airflow and cold function switches on when the set time has elapsed. spots. Off The DELTA fan heater comes in two sizes: • TP1 = 3-9 kW - small cabinet Fan on • TP2 = 15-21 kW - large cabinet Half fan and half heat effect TP1: 372 mm TP1: 300 mm TP2: 462 mm TP2: 360 mm Full fan and half heat effect Full fan and full heat effect TP1: 435 mm TP2: 540 mm TP1: 322 mm ELECTRICAL INSTALLATION TP2: 392 mm Permanent installation must always be performed by an authori- zed electrician in accordance with relevant laws and regulations.
    [Show full text]
  • Airflow Measuring System Using Piezometer Ring – IM-105
    IM-105 Piezometer Ring June 2021 Installation, Operation & Maintenance Manual REVIEW AMCA BULLETIN 410 PRIOR TO INSTALLATION This manual has been prepared to guide the users of an airflow measuring system using a piezometer ring in the proper installation, operation and maintenance procedures to ensure maximum equipment life with trouble-free operation. For safe installation, startup and operational life of this equipment, it is important that all involved with the equipment be well versed in proper fan safety practices and read this manual. It is the user’s responsibility to make sure that all requirements of good safety practices and any applicable safety codes are strictly adhered to. Because of the wide variety of equipment covered in this manual, the instructions given here are general in nature. Additional product and engineering information is available at www.tcf.com. SAFETY NOTICE Refer to the safety section(s) in this manual prior to installing or servicing the fan. The most current version of this installation and maintenance manual can be found on our website at www.tcf.com/resources/im-manuals. Table of Contents Safety & Hazard Warnings ...........................................................................................................................................................................2 Shipping & Receiving ....................................................................................................................................................................................2 Handling ......................................................................................................................................................................................................
    [Show full text]
  • Optimization of Heat Exchanger Design and Fan Selection for Single Stage Refrigeration/Heat Pump Systems T
    Purdue University Purdue e-Pubs International Refrigeration and Air Conditioning School of Mechanical Engineering Conference 1986 Optimization of Heat Exchanger Design and Fan Selection for Single Stage Refrigeration/Heat Pump Systems T. H. Kuehn Follow this and additional works at: http://docs.lib.purdue.edu/iracc Kuehn, T. H., "Optimization of Heat Exchanger Design and Fan Selection for Single Stage Refrigeration/Heat Pump Systems" (1986). International Refrigeration and Air Conditioning Conference. Paper 24. http://docs.lib.purdue.edu/iracc/24 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html OPTIMIZATION OF HEAT EXCHANGER DESIGN AND FAN SELECTION FOR SINGLE STAGE REFRIGERATION/HEAT PUMP SYSTEMS THOMAS H. KUEHN Thermal Environmental Engineering Division, Department of Mechanical Engineering. University of Minnesota, Minneapolis, Minnesota, U.S.A. 1. INTRODUCTION Thermodynamic second law analysis can be employed to determine where losses occur in a given system. Inputs to this analysis include thermodynamic state information, mass flows, work transfers and heat exchange. Applications to vapor compression refrigeration and heat pump systems are outlined in references /1/ and /2/. However additional details of the processes are required to identify the nature of the losses. From this detailed information one can then begin to develop simple models useful in component or system thermodynamic optimization. A thermodynamic second law analysis is performed on an air cooled single stage mechanical vapor compression refrigeration system operating steadily under full load.
    [Show full text]
  • Cooling Your Home with Fans and Ventilation
    DOE/GO-102001-1278 FS228 June 2001 Cooling Your Home with Fans and Ventilation You can save energy and money when Principles of Cooling you ventilate your home instead of using your air conditioner, except on the hottest Cooling the Human Body days. Moving air can remove heat from Your body can cool down through three your home. Moving air also creates a wind processes: convection, radiation, and per- chill effect that cools your body. spiration. Ventilation enhances all these processes. Ventilation cooling is usually combined with energy conservation measures like Convection occurs when heat is carried shading provided by trees and window away from your body via moving air. If the treatments, roof reflectivity (light-colored surrounding air is cooler than your skin, roof), and attic insulation. Mechanical air the air will absorb your heat and rise. As circulation can be used with natural venti- the warmed air rises around you, cooler air lation to increase comfort, or with air con- moves in to take its place and absorb more ditioning for energy savings. of your warmth. The faster this convecting air moves, the cooler you feel. Ventilation provides other benefits besides cooling. Indoor air pollutants tend to accu- Radiation occurs when heat radiates mulate in homes with poor ventilation, and across the space between you and the when homes are closed up for air condi- objects in your home. If objects are tioning or heating. warmer than you are, heat will travel toward you. Removing heat through ventila- tion reduces the tem- perature of the ceiling, walls, and furnishings.
    [Show full text]
  • HMIC Series Fan and Bypass Humidifiers
    HMIC Series Fan and Bypass Humidifiers Model: HMICSB12B Model: HMICLF18B Model: HMICLB17B As warm air passes through the humidifier pad and water flows through it, natural evaporation takes place. This creates comforting humidity which is distributed throughout the house by your forced air heating system. OPTIMAL GENERATION OF COMFORTING THREE HUMIDITY CONTROL OPTIONS. MOISTURE. Choose between 3 separate control options; the Working together, water solenoid valve, water humidistat, the HumidiTrac and the Thermidistat metering orifice, water distribution tray and aluminum control. Each option provides precise control of humidifier pad efficiently generate maximum levels of humidity levels in your home. comforting moisture. QUIET OPERATION. SIMPLE, INFREQUENT MAINTENANCE. Nearly silent operation is the result of ICP Designed for easy serviceability. In most instances, it Branded Humidifier’s precision engineered fan takes less than 1/2 hour since maintenance (including and motor combination in the large fan powered changing the humidifier pad) is performed once a unit. In all units, air is quietly drawn through the season. Unlike portables, there are no reservoirs humidifier pad which efficiently turns water into which need to be frequently cleaned and refilled. water vapor to humidify your home. LONG LASTING HIGH QUALITY COMPONENTS. WARRANTY. With proper maintenance, your humidifier will last for Electrical components are covered by a five-year many years. That’s because it’s designed with durable limited warranty and the entire unit is backed by UV and corrosion resistant plastic. This plastic resists a one-year limited warranty. deterioration even when exposed to Ultraviolet light sources common in many systems today. HMIC Series Humidifiers include a packet with logos for the ICP brands.
    [Show full text]
  • Analysis of Heat Transfer in Air Cooled Condensers
    Analysis of Heat Transfer in Air Cooled Condensers Sigríður Bára Ingadóttir FacultyFaculty of of Industrial Industrial Engineering, Engineering, Mechanical Mechanical Engineering Engineering and and ComputerComputer Science Science UniversityUniversity of of Iceland Iceland 20142014 ANALYSIS OF HEAT TRANSFER IN AIR COOLED CONDENSERS Sigríður Bára Ingadóttir 30 ECTS thesis submitted in partial fulfillment of a Magister Scientiarum degree in Mechanical Engineering Advisors Halldór Pálsson, Associate Professor, University of Iceland Óttar Kjartansson, Green Energy Group AS Gestur Bárðarson, Green Energy Group AS Faculty Representative Ármann Gylfason, Associate Professor, Reykjavík University Faculty of Industrial Engineering, Mechanical Engineering and Computer Science School of Engineering and Natural Sciences University of Iceland Reykjavik, May 2014 Analysis of Heat Transfer in Air Cooled Condensers Analysis of Heat Transfer in ACCs 30 ECTS thesis submitted in partial fulfillment of a M.Sc. degree in Mechanical Engi- neering Copyright c 2014 Sigríður Bára Ingadóttir All rights reserved Faculty of Industrial Engineering, Mechanical Engineering and Computer Science School of Engineering and Natural Sciences University of Iceland VRII, Hjardarhagi 2-6 107, Reykjavik, Reykjavik Iceland Telephone: 525 4000 Bibliographic information: Sigríður Bára Ingadóttir, 2014, Analysis of Heat Transfer in Air Cooled Condensers, M.Sc. thesis, Faculty of Industrial Engineering, Mechanical Engineering and Computer Science, University of Iceland. Printing: Háskólaprent, Fálkagata 2, 107 Reykjavík Reykjavik, Iceland, May 2014 Abstract Condensing units at geothermal power plants containing surface condensers and cooling towers utilize great amounts of water. Air cooled condensers (ACCs) are not typically paired with dry or flash steam geothermal power plants, but can be a viable solution to eliminate the extensive water usage and vapor emissions related to water cooled systems.
    [Show full text]
  • Effects of Varying Fan Speed on a Refrigerator/Freezer System
    University of Illinois at Urbana-Champaign Air Conditioning and Refrigeration Center A National Science Foundation/University Cooperative Research Center Effects of Varying Fan Speed on a Refrigerator/Freezer System A. R. Cavallaro and C. W. Bullard ACRC TR-63 July 1994 For additional information: Air Conditioning and Refrigeration Center University of Illinois Mechanical & Industrial Engineering Dept. 1206 West Green Street Urbana, IL 61801 Prepared as part of ACRC Project 30 Cycling Performance of Refrigerator-Freezers (217) 333-3115 C. W. Bullard, Principal Investigator The Air Conditioning and Refrigeration Center was founded in 1988 with a grant from the estate of Richard W. Kritzer, the founder of Peerless of America Inc. A State of Illinois Technology Challenge Grant helped build the laboratory facilities. The ACRC receives continuing support from the Richard W. Kritzer Endowment and the National Science Foundation. The following organizations have also become sponsors of the Center. Acustar Division of Chrysler Allied Signal, Inc. Amana Refrigeration, Inc. Brazeway, Inc. Carrier Corporation Caterpillar, Inc. E. I. duPont Nemours & Co. Electric Power Research Institute Ford Motor Company Frigidaire Company General Electric Company Harrison Division of GM ICI Americas, Inc. Modine Manufacturing Company Peerless of America, Inc. Environmental Protection Agency U.S. Army CERL Whirlpool Corporation For additional information: Air Conditioning & Refrigeration Center Mechanical & Industrial Engineering Dept. University of Illinois 1206 West Green Street Urbana, IL 61801 217 333 3115 Abstract Air-side heat transfer correlations were developed to describe variable conductance models for the condenser and evaporator. Few experimentally estimated parameters described well the changes of refrigerant and air-side conditions over a wide range of steady-state operating conditions for the extensively instrumented test refrigerator.
    [Show full text]
  • Ultra-Aire 150H Whole House Ventilating Dehumidifier UA-150H • Part No
    INSTALLER’S & OWNER’S MANUAL Ultra-Aire 150H Whole House Ventilating Dehumidifier UA-150H • Part No. 4024371 • Serial No.________________________________ Dehumidification Fresh Air Ventilation The highly efficient Ultra-Aire 150H dehumidifier utilizes refrigeration Optional fresh outdoor air may be ducted to the unit via a six inch to cool the incoming air stream below its dew point. This cooled and round duct. This provides fresh air to dilute pollutants and maintain drier air is used to pre-cool the incoming air stream resulting in a high oxygen content in the air. The amount of fresh air ventilation can significant increase in overall efficiency. After the pre-cooling stage, be regulated by a variety of dampers and controls. the processed air is reheated by passing through the condenser coil. The heat removed by the evaporator coil is returned to the air stream, Air Filtration resulting in an overall temperature increase of the air leaving the unit. The UA-150H includes air filtration to improve indoor air quality. A MERV-11 media filter is standard. An optional MERV-14 deep pleated The Ultra-Aire 150H is controlled by 24 volt remote wired controls. A 95% media filter is available for optimum air filtration and to reduce variety of controls are available suitable to various applications. potentially harmful airborne particles. If the optional filter is chosen, the standard filter operates as a prefilter. HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER © 2006 Therma-Stor LLC Manual P/N TS-245h 6/07 TABLE OF CONTENTS Table of Contents Safety Precautions .......................................................................3 5.3H Damper Operation and Setting ...............................13 1.
    [Show full text]
  • The Use of Portable Fans and Portable Air Conditioning Units During COVID-19 in Long-Term Care and Retirement Homes
    AT A GLANCE The Use of Portable Fans and Portable Air Conditioning Units during COVID-19 in Long- term Care and Retirement Homes Key Findings Careful consideration should be given to the use of portable fans and air conditioning units in long-term care homes or retirement homes. Portable fans and portable air conditioning units require routine cleaning and preventative maintenance. Portable fans and portable air conditioning units need to be strategically located to minimize risk of potential healthcare-associated infections. Alternative cooling methods should be explored in the long-term care setting. Introduction Seasonal hot weather including extreme heat events (EHE) can impact our health and well-being, including those residing in long-term care homes (LTCH) and retirement homes (RH) where central air conditioning is unavailable. Several long-term care and retirement homes have old building design with no centralized heating, ventilation, and air conditioning (HVAC) system. Long-term care and retirement homes need to use alternative methods such as portable fans or portable air conditioning (AC) units to improve residents’ comfort and reduce the illnesses associated with excessive heat. Health care facilities such as LTCH need to be aware of the potential risk of infection transmission associated with some of the heat relief options. This document provides recommendations for consideration on the use of portable fans and air conditioning units in these facilities. Background The risk of heat-related illnesses is higher in elderly
    [Show full text]
  • Improving Ventilation and Indoor Air Quality During Wildfire Smoke Events Recommendations for Schools and Buildings with Mechanical Ventilation
    Improving Ventilation and Indoor Air Quality during Wildfire Smoke Events Recommendations for Schools and Buildings with Mechanical Ventilation Overview • Smoke is a complex mixture of carbon dioxide (CO2), water vapor, carbon monoxide (CO), hydrocarbons, other organic chemicals, nitrogen oxides (NOX), trace minerals, and particulate matter. o Particulate matter consists of solid particles and liquid droplets suspended in the air. Particles with diameters less than 10 microns (PM10) are upper respiratory tract and eye irritants. o Smaller particles (PM2.5) are the greatest health concern – they can be inhaled deep into the lungs, and can affect respiratory and heart health. o Carbon monoxide, a colorless, odorless gas produced by incomplete combustion, is a particular health concern and levels are highest during the smoldering stages of a fire. • Outdoor (ambient) air pollutants, including smoke, enter and leave buildings in three primary ways: 1. Mechanical ventilation systems, which actively draw in outdoor air through intake vents and distribute it throughout the building. 2. Natural ventilation (opening of doors or windows). 3. Infiltration, the passive entry of unfiltered outdoor air through small cracks and gaps in the building shell. • Tightly closed buildings reduce exposure to outdoor air pollution. Upgrading the filter efficiency of the heating, ventilating, and air-conditioning (HVAC) system and changing filters frequently during smoke events greatly improves indoor air quality. Supplementing with HEPA filters, particularly those with activated charcoal or other adsorbents, improves air quality even more. • During long-term smoke events, take advantage of periods of improved air quality (such as during rain or shifts in wind) to use natural ventilation to flush-out the building.
    [Show full text]