<<

is only permissible if the cylinder is until it stops. Follow instructions disconnected and removed from the in this manual for proper storage pit. procedures and the important warnings and safe guards on pages. OPERATING INSTRUCTIONS When an LP tank is not connected, Lighting Procedures and to help prevent dirt or other 1. Check all connections for leaks foreign particles from clogging the using the “soapy water” test. HVR, hang the end of the HVR hose 2. Check for any blockage to the from the outer ring. venturi tube or burner. Remove any foreign objects or matter. Inspect the flame at the burner to 3. Be sure the burner control knob is ensure a proper flame. “OFF”. 4. Open the LP cylinder valve ONLY 1-1/2 turns by turning counterclockwise. 5. Insert a

long-nose gas Control Valve next to the burner, making sure OFF it sits over the To protect your from burner. Open weather, always keep your fire pit the valve next ON covered while not in use. The cover to the burner must be removed and stored safely by turning the lever to the ON away from the fire pit when the fire position. If the burner does pit is in use. not light within 4 or 5 seconds, turn the control knob off, wait 5 minutes, Cleaning and repeat the process. Clean the stand of the fire pit using hot soapy water. High temperature CAUTION spray paint can be used to touch up any scratches in the paint. Use Model #: GC-LOG-2 The fire pit can become very a wire brush to remove any loose hot while in use. Do not paint before touching up. Make sure Propane touch any portion of the fire to dry thoroughly before use. The pit except for the control rocks can be removed from the fire knob next to the regulator. pit and cleaned using soapy water or sprayed off using a hose sprayer. The It may be necessary to use outside of the burner may be wiped Warning & Instruction Booklet protective gloves. clean using soapy water. A pipe cleaner can be used to remove any For Outdoor Use Only Shutting the Fire pit Off spider webs from the venturi tube. Turn the control knob at the Read this manual before each use. Failure to follow these instructions regulator off by turning clockwise could result in fire or explosion, which could cause serious personal The burner flame should then go injury and/or property damage. out. Turn off the LP cylinder valve Po Box 4057 • Logan, UT 84323 • 1.800.650.2433 • www.campchef.com by turning the knob clockwise 0809-GCLOG-Instructions

0809-GCLOG-Instructions.indd 1-2 8/19/09 10:11:12 AM WARNING FAILURE TO FOLLOW PROPER Parts List PROCEDURES AND SAFEGUARDS If the information in this MAY RESULT IN SERIOUS PERSONAL manual is not followed INJURY OR PROPERTY DAMAGE. exactly, a fire or explosion USE CAUTION AND COMMON SENSE WHEN OPERATING YOUR FIRE PIT may result causing property damage, personal injury or WARNING loss of life. DO NOT use this fire pit in a manner other than WARNING its intended purpose. Not Do not store or use gasoline intended for commercial or other flammable vapors use. Not intended to be and liquids in the vicinity of installed or used in or on a this or any other appliance. recreational vehicle or boat. Keep a fire extinguisher WHAT TO DO IF YOU SMELL GAS. • Do not try to light any appliance. accessible at all times. The • Do not touch any electrical switch; use of alcohol, prescription do not use any phone in your or nonprescription drugs building. may impair the consumer’s • Immediately call your gas supplier ability to properly assemble from a neighbor’s phone. Follow the gas supplier’s instructions. or safely operate this fire • If you cannot reach your gas pit. Solid shall not be supplier, call the fire department. burned in this gas fireplace. Installation and service must be performed by a qualified installer, FOR OUTDOOR USE ONLY! service agency or gas supplier. Do not operate the fire pit indoors, WARNING in a garage, or in any other enclosed area or under overhead construction. Improper installation, Do not operate fire pit near adjustment, alteration, flammable materials such as decks, service or maintenance can fences, porches or carports. cause injury or property A minimum clearance range of 72” inches is recommended. Do not damage. Read the store the fire pit near gasoline or Assembly Instructions installation, operating and other combustible liquids or where maintenance instructions combustible vapors may be present. 1) Connect regulator hose to brass fitting on fire pit. thoroughly before installing Tighten using either a 3/4" or adjustable end wrench. or servicing this equipment. Children and adults should be (Do not hand tighten only.) Make sure to check this alerted to the hazards of high connection for leaks. See the section Checking for Leaks. surface temperatures and should READ ALL INSTRUCTIONS AND stay away to avoid burns or clothing 2) Arrange the 12 pounds of lava rock around the WARNINGS BEFORE USE! YOUR ignition. Young children should be burner. For a more realistic looking flame arrange the SAFETY IS VERY IMPORTANT - rock to cover most of the tube burner. carefully supervised when they are in

0809-GCLOG-Instructions.indd 3-4 8/19/09 10:11:44 AM the area of the appliance. Clothing Do not bump or tip fire pit. If While the fire pit is not in use, the Connecting the LP Tank or other flammable materials should Fire pit becomes extremely hot - gas must be turned off at the supply 1. The knob on the LP tank must be not be hung from the appliance, allow fire pit to cool completely cylinder. The fire pit should be shut closed. See that the knob is turned or placed on or near the appliance. before handling. If you must handle off and all supply valves (on piping clockwise to a full stop. Any guard or other protective device the fire pit while it is hot, always or on cylinders) should be 2. Check that the control knob on removed for servicing the appliance wear protective oven mitts or heat closed in the event that the odor of the fire pit is turned off. must be replaced prior to operating resistant gloves when handling the unburned gas is detected. Do not 3. Remove the protective cap from the appliance. fire pit or its components. attempt to use the unit until any gas the LP tank valve and coupling nut, leaks are fixed. Do not use the fire if present. Installation and repair should be DO NOT obstruct flow of pit if the burner fails to light or fails 4. Hold the regulator done by a qualified service person air and/or ventilation air for fire pit. to remain lit. Under such conditions, in one hand and insert The appliance should be inspected gas should be shut off and fuel the nipple into the before use and at least annually Do not wear loose clothing while cylinders should be disconnected. valve outlet. Be sure by a qualified service person. More operating the fire pit. Tie back long Do not operate under high wind the nipple is centered frequent cleaning may be required hair while operating the fire pit. conditions. All installations are in the valve outlet. as necessary. It is imperative that ALWAYS wear fully covering shoes to conform to local codes. In the The coupler connects control compartment, burners and while operating the fire pit. absence of local codes, installation to the large outside threads on the circulating air passageways of the should conform to the National Fuel valve outlet appliance be kept clean. Allow fire pit and its components Gas Code, ANSIZ223.1/NFPA 54 5. Hand tighten the coupler to cool completely before clockwise until it comes to a full Use caution when assembling and conducting any routine cleaning or Fire pit should be installed with the stop. Firmly tighten by hand only. operating fire pit to avoid cuts and maintenance. Do not move the fire hose regulator assembly extended 6. Place the tank to the side or rear scrapes from rough or sharp edges. pit when in use. Allow the fire pit to at full length of hose directly of the fire pit. Make sure the hose cool before moving or storing. away from the burner. When so does not touch any part of the Do not move the fire pit while it configured, placement results in burner drum housing. is in use. Allow the fire pit to cool Do not use this appliance if any part maximum tank to fire pit distance. completely before moving or storing. has been under water. Immediately When fire pit is operated, the hose/ (B) Nipple has to call a qualified service technician to regulator and gas tank should be be centered into When in use, the fire pit must be inspect the appliance and to replace on a line perpendicular to wind the LP tank valve on a level, stable surface in an area any part of the control system and direction. Placing tank closer than clear of combustible material. An any gas control which has been 48” to the fire pit can overheat the asphalt surface (blacktop) may not under water. tank and cause release of propane be acceptable for this purpose. Do through relief openings and can not operate fire pit on flammable An LP cylinder not connected for use result in tank fire or explosion. material such as carpet or a wood should not be stored in the vicinity (C) Hold deck. Store the fire pit in a dry, of fire pit or any other fire pit. Do coupling nut and regulator as protected location. not store spare LP cylinders within 10 shown for proper feet of fire pit. connection to LP This fire pit is not intended for and LP cylinders must be stored outdoors, tank valve should never be used as a heater. out of reach of children. Do not store a spare LP-gas cylinder under DO NOT leave fire pit unattended or near this fire pit. Never fill the while in use. Operate the fire pit cylinder beyond 80 percent full. with close supervision. Failure to follow these instructions exactly could result in a fire causing DO NOT operate around children or death or serious injury. animals.

0809-GCLOG-Instructions.indd 5-6 8/19/09 10:11:54 AM CAUTION Do not allow dirt or foreign material CAUTION 2. With all valves closed, apply the to get into or onto tank connection leak check solution (50/50 mix of dish In the connection process, the when it is not attached to the fuel The gas pressure regulator washing soap detergent and water) HVR side of the connection supply system. Use the protective cap provided with this appliance to all gas carrying connections and will seal on the back check in provided. Place dust cap on cylinder must be used. This regulator fittings. valve outlet whenever the cylinder 3. Open tank valve. Presence of the valve, resulting in a slight is not in use. Only install the type of is set for an outlet pressure bubbles at areas of wet solution resistance. The connection dust cap on the cylinder valve outlet of 0.5 psi. Replacement indicates a gas leak. If leaks are requires about one-half to that is provided with the cylinder pressure regulators and detected or you smell or hear gas, three quarters additional valve. Other types of caps or plugs hose assemblies must be shut off the valve and repair the leak turn to complete connection. may result in leakage of propane. those specified by the fire or replace the defective part. Any fuel supply cylinder Cylinders must be filled before initial pit manufacturer. See rating Do not use the fire pit until all leaks used must be constructed use. All handling, transport, filling sticker on side of fire pit for are corrected. and marked in accordance and storage of LP gas cylinders regulator model number. with specifications for must be in accordance with NFPA The regulator/hose assembly CAUTION propane cylinders of 58 Storage and Handling of Liquid should be handled carefully The burner must be inspected Petroleum Gasses, or CAN/CSA the U.S. Department of b149.2 Propane Installation Code. to prevent contamination by before each use of the Transportation (DOT)CFR 49 foreign objects and dirt. The appliance. If it is evident or CAN/CSA B339. Cylinders must be suitably tied down assembly should be inspected that the burner is damaged during transport. Do not place any before use and any dirt or it must be replaced before The fire pit is to be used only with other items on top of cylinders at contamination should be the appliance is put into use. the 20 pound, vertical standing any time. vapor withdrawal type tank. This wiped off. The hose assembly The burner must be replaced fire pit is designed to operate on LP Cylinders are not to be exposed to must be replaced prior to the only by factory authorized (Liquefied Propane) gas only. The excessive temperatures or high heat. appliance being used if there parts as specified by the 20 lb LP cylinder used with this fire Refer to the data plate for model is any evidence of excessive manufacturer. pit must conform to the following identification. Units are factory abrasion or wear, or if the requirements: equipped for use on only one type • Type 1 Connections of fuel. These units cannot be, hose is damaged. In order to When setting up the fire pit and • Diameter - 12” (30.5cm) and should not be used on other insure proper operation, any tank, it is recommended to have • Height - 18” (45.7cm) types of fuels. Doing so can cause replacement of the regulator the tank and fire pit on a line • Maximum capacity of 20 pounds severe damage to the unit and the assembly must be with parts perpendicular to the wind direction. The gas cylinder used must include a installation area and the added risk authorized by manufacturer. The gas hose/regulator assembly collar to protect the cylinder valve. of serious injury. Any attempt to should be totally extended to the The cylinder supply system must be operate this product on fuels for Valve/pressure regulators maximum distance so that the hose arranged for vapor withdrawal. which it is not designed voids the are factory set to the correct is straight and the tank is as far from manufacturer’s warranty. operating pressures. No the fire pit as possible. LP tanks Follow the instructions stated on attempts should be made to are intended for operation in the gas cylinder tanks when filling or This unit is not to be utilized with adjust these settings. upright position only. Care should transporting tanks. Failure to do so a non-self-contained LP-gas supply be taken to protect the fuel supply could result in problems relating to system. Checking for Leaks hose from damage from either foot overfilling, excessive venting release 1. After all connections are or vehicle traffic. If the fire pit is not of gas and to regulator freezing. completed, check all connections in use, the gas must be turned off at Never fill the cylinder more than 80 and fittings for leaks with a soap the supply cylinder and the cylinder percent full. solution. should be disconnected from the fire pit. Storage of the fire pit indoors

0809-GCLOG-Instructions.indd 7-8 8/19/09 10:11:55 AM