Introduction to Storage Area Networks

Total Page:16

File Type:pdf, Size:1020Kb

Introduction to Storage Area Networks Front cover Introduction to Storagee Area Networks Learn basic SAN terminology and component uses Introduce yourself to the benefits a SAN can bring Discover the IBM TotalStorage SAN portfolio Jon Tate Rajani Kanth Andre Telles ibm.com/redbooks International Technical Support Organization Introduction to Storage Area Networks April 2005 SG24-5470-02 Note: Before using this information and the product it supports, read the information in “Notices” on page xv. Third Edition (May 2005) This edition applies to the IBM TotalStorage portfolio. © Copyright International Business Machines Corporation 1999, 2003, 2005. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Figures . xi Tables . xiii Notices . xv Trademarks . xvi Preface . xvii The team that wrote this redbook. xviii Become a published author . xx Comments welcome. xx Chapter 1. Introduction to storage area networks . 1 1.1 The need for a SAN. 3 1.1.1 Infrastructure simplification . 4 1.1.2 Information lifecycle management . 5 1.1.3 Business continuance . 5 1.2 The storage area network . 5 1.3 Storage device connectivity. 7 1.3.1 Server-attached storage . 8 1.3.2 Fibre Channel . 8 1.3.3 FICON® . 8 1.3.4 SCSI . 9 1.3.5 Ethernet interface . 9 1.3.6 Network Attached Storage . 9 1.3.7 iSCSI . 9 1.3.8 iFCP . 10 1.3.9 FCIP . 10 1.4 SAN definition and evolution . 11 1.4.1 Fibre Channel architecture . 12 1.5 SAN components . 16 1.5.1 SAN servers . 16 1.5.2 SAN storage . 16 1.5.3 SAN interconnects . 17 1.6 Storage technology trends driving SAN solutions . 17 1.6.1 Today’s SAN requirements . 18 1.6.2 SAN standards . 19 1.6.3 SANs and storage virtualization . 20 © Copyright IBM Corp. 1999, 2003, 2005. All rights reserved. iii Chapter 2. SAN servers and storage . 23 2.1 Servers and storage environments . 25 2.1.1 The challenge . 25 2.2 Server environments . 27 2.2.1 zSeries servers . 28 2.2.2 pSeries servers . 29 2.2.3 iSeries™ servers. 30 2.2.4 xSeries servers . 31 2.3 IBM storage products . 32 2.4 IBM TotalStorage DS Family. 32 2.4.1 Entry-level disk systems . 32 2.4.2 Mid-range disk systems . 35 2.4.3 Enterprise disk systems . 41 2.5 IBM Tape Storage Systems . 46 2.5.1 IBM Tape autoloaders. 46 2.5.2 Tape drives . 51 2.6 Storage virtualization in the SAN. 60 2.6.1 Block virtualization at the LUN level . 61 Levels of storage virtualization . 61 2.6.2 Server, fabric, storage subsystem or file system virtualization . 62 2.6.3 Virtualization models . 63 2.6.4 IBM TotalStorage SAN Volume Controller . 64 2.6.5 IBM TotalStorage SAN File System . 66 2.7 Network Attached Storage . 67 Chapter 3. SAN fabrics and connectivity . 71 3.1 The SAN environment . 73 3.1.1 The storage area network . 73 3.2 Fibre Channel topologies . 74 3.2.1 Point-to-point. 75 3.2.2 Arbitrated loop. 76 3.2.3 Switched fabric . 77 3.3 Fibre Channel technology components. 78 3.3.1 Fibre Channel transmission rates . 79 3.3.2 SerDes . 79 3.3.3 Backplane and blades. 79 3.4 Fibre Channel interconnects . 79 3.4.1 Ten Gigabit small Form-factor Pluggable . 80 3.4.2 Small Form Factor Pluggable Media. 80 3.4.3 Gigabit Interface Converters . 81 3.4.4 Gigabit Link Modules. 82 3.4.5 Media Interface Adapters . 83 3.4.6 1x9 Transceivers. 84 iv Introduction to Storage Area Networks 3.4.7 Cables . 84 3.4.8 Host bus adapters . 86 3.4.9 Inter-switch links . 87 3.4.10 Cascading . 87 3.4.11 Latency . 88 3.4.12 Trunking . 88 3.4.13 Frame filtering . ..
Recommended publications
  • FICON Native Implementation and Reference Guide
    Front cover FICON Native Implementation and Reference Guide Architecture, terminology, and topology concepts Planning, implemention, and migration guidance Realistic examples and scenarios Bill White JongHak Kim Manfred Lindenau Ken Trowell ibm.com/redbooks International Technical Support Organization FICON Native Implementation and Reference Guide October 2002 SG24-6266-01 Note: Before using this information and the product it supports, read the information in “Notices” on page vii. Second Edition (October 2002) This edition applies to FICON channel adaptors installed and running in FICON native (FC) mode in the IBM zSeries procressors (at hardware driver level 3G) and the IBM 9672 Generation 5 and Generation 6 processors (at hardware driver level 26). © Copyright International Business Machines Corporation 2001, 2002. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . vii Trademarks . viii Preface . ix The team that wrote this redbook. ix Become a published author . .x Comments welcome. .x Chapter 1. Overview . 1 1.1 How to use this redbook . 2 1.2 Introduction to FICON . 2 1.3 zSeries and S/390 9672 G5/G6 I/O connectivity. 3 1.4 zSeries and S/390 FICON channel benefits . 5 Chapter 2. FICON topology and terminology . 9 2.1 Basic Fibre Channel terminology . 10 2.2 FICON channel topology. 12 2.2.1 Point-to-point configuration . 14 2.2.2 Switched point-to-point configuration . 15 2.2.3 Cascaded FICON Directors configuration. 16 2.3 Access control. 18 2.4 Fibre Channel and FICON terminology.
    [Show full text]
  • Secure Data Storage – White Paper Storage Technologies 2008
    1 Secure Data Storage – White Paper Storage Technologies 2008 Secure Data Storage - An overview of storage technology - Long time archiving from extensive data supplies requires more then only big storage capacity to be economical. Different requirements need different solutions! A technology comparison repays. Author: Dr. Klaus Engelhardt Dr. K. Engelhardt 2 Secure Data Storage – White Paper Storage Technologies 2008 Secure Data Storage - An overview of storage technology - Author: Dr. Klaus Engelhardt Audit-compliant storage of large amounts of data is a key task in the modern business world. It is a mistake to see this task merely as a matter of storage technology. Instead, companies must take account of essential strategic and economic parameters as well as legal regulations. Often one single technology alone is not sufficient to cover all needs. Thus storage management is seldom a question of one solution verses another, but a combination of solutions to achieve the best possible result. This can frequently be seen in the overly narrow emphasis in many projects on hard disk-based solutions, an approach that is heavily promoted in advertising, and one that imprudently neglects the considerable application benefits of optical storage media (as well as those of tape-based solutions). This overly simplistic perspective has caused many professional users, particularly in the field of long-term archiving, to encounter unnecessary technical difficulties and economic consequences. Even a simple energy efficiency analysis would provide many users with helpful insights. Within the ongoing energy debate there is a simple truth: it is one thing to talk about ‘green IT’, but finding and implementing a solution is a completely different matter.
    [Show full text]
  • Cisco MDS 9250I Multiservice Fabric Switch for IBM an Optimized Solution for Departmental and Branch-Office Sans As Well As Large-Scale Sans
    IBM Systems Data Sheet Cisco MDS 9250i Multiservice Fabric Switch for IBM An optimized solution for departmental and branch-office SANs as well as large-scale SANs Cisco MDS 9250i Multiservice Fabric Switch for IBM® System Highlights Storage® is an optimized platform for deploying high-performance SAN extension solutions, distributed intelligent fabric services and ●● ●●Provide 16 Gbps connectivity in a cost-effective multiprotocol connectivity for both open systems and high-densit y Fibre Channel switch mainframe environments. With a compact form factor and advanced ●● ●●Enable storage area network (SAN) con- capabilities normally available only on director-class switches, solidation with integrated multiprotocol MDS 9250i is an ideal solution for departmental and remote branch- support office SANs as well as large-scale SANs in conjunction with the ●● ●●Deliver high-p erformance Fibre Channel Cisco MDS 9710 Multilayer Director. over IP (FCIP) and fast disaster recovery ●● ●●Support hardware-bas ed virtual fabric MDS 9250i offers up to 40 16 Gbps Fibre Channel ports, two isolation with virtual SANs (VSANs) and 10 Gigabit Ethernet IP storage services ports and eight 10 Gigabit Fibre Channel routing with Inter-V SAN routing (IVR) Ethernet Fibre Channel over Ethernet (FCoE) ports in a fixed, two- rack-unit (2RU) form factor. MDS 9250i connects to existing native Fibre ●● ●●Enable cost- effective, high- performing Channel networks, protecting current investments in storage networks. Fibre Channel and FCIP connectivity for open systems and mainframe environments Main features and benefits ●● ●●Cisco Data Mobility Manager (DMM) as a MDS 9250i provides unique multiservice and multiprotocol functions in distributed fabric service a compact 2RU form factor.
    [Show full text]
  • IBM System Z9 Enterprise Class
    The server built to help optimize your resources throughout the enterprise IBM System z9 Enterprise Class A “classic” might just be the best Today’s market finds that business needs are changing, and having a com­ petitive advantage isn’t always about having more or being bigger, but more about being smarter and responding faster to change and to your clients. Often, being reactive to change has led to infrastructures with mixed technolo­ gies, spread across an enterprise, that are complex and difficult to control and costly to manage. Integration of appli­ cations and data is limited and difficult. Using internal information to make insightful decisions for the company Highlights can be difficult because knowing you are using the “best” data—that which is ■ Strengthening the role of the ■ Continued improvement in most current and complete—may not mainframe as the data hub of IBM FICON® performance and be possible. the enterprise throughput In many situations, investments have ■ New versatile capacity settings ■ On demand innovative tech­ been made in disparate technologies designed to optimize capacity nologies to help meet ever- that may fall short of meeting their and cost changing business demands goals. Merging information from one branch to another may not be possible ■ IBM System z9™ Integrated and so company direction is set with Information Processor (IBM zIIP) is designed to improve resource optimization and lower the cost of eligible work only a portion of the data at hand, and help achieve advanced I/O function and But data management can be a big in a global economy that can really hurt.
    [Show full text]
  • Troubleshooting FICON
    Send documentation comments to [email protected] CHAPTER 16 Troubleshooting FICON Fibre Connection (FICON) interface capabilities enhance the Cisco MDS 9000 Family by supporting both open systems and mainframe storage network environments. Inclusion of Control Unit Port (CUP) support further enhances the MDS offering by allowing in-band management of the switch from FICON processors. This chapter includes the following sections: • FICON Overview, page 16-1 • FICON Configuration Requirements, page 16-6 • Initial Troubleshooting Checklist, page 16-7 • FICON Issues, page 16-9 FICON Overview The Cisco MDS 9000 Family supports the Fibre Channel, FICON, iSCSI, and FCIP capabilities within a single, high-availability platform. Fibre Channel and FICON are different FC4 protocols and their traffic are independent of each other. If required, devices using these protocols can be isolated using VSANs. The Cisco SAN-OS FICON feature supports high-availability, scalability, and SAN extension technologies including VSANs, IVR, FCIP, and PortChannels. Tip When you create a mixed environment, place all FICON devices in one VSAN (other than the default VSAN) and segregate the FCP switch ports in a separate VSAN (other than the default VSAN). This isolation ensures proper communication for all connected devices. You can implement FICON on the following switches: • Any switch in the Cisco MDS 9500 Series. • Any switch in the Cisco MDS 9200 Series (including the Cisco MDS 9222i Multiservice Modular Switch). • Cisco MDS 9134 Multilayer Fabric Switch. • MDS 9000 Family 18/4-Port Multiservice Module. Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x OL-9285-05 16-1 Chapter 16 Troubleshooting FICON FICON Overview Send documentation comments to [email protected] Note The FICON feature is not supported on Cisco MDS 9120, 9124 or 9140 switches, the 32-port Fibre Channel switching module, Cisco Fabric Switch for HP c-Class BladeSystem or Cisco Fabric Switch for IBM BladeCenter.
    [Show full text]
  • IBM Z Connectivity Handbook
    Front cover IBM Z Connectivity Handbook Octavian Lascu John Troy Anna Shugol Frank Packheiser Kazuhiro Nakajima Paul Schouten Hervey Kamga Jannie Houlbjerg Bo XU Redbooks IBM Redbooks IBM Z Connectivity Handbook August 2020 SG24-5444-20 Note: Before using this information and the product it supports, read the information in “Notices” on page vii. Twentyfirst Edition (August 2020) This edition applies to connectivity options available on the IBM z15 (M/T 8561), IBM z15 (M/T 8562), IBM z14 (M/T 3906), IBM z14 Model ZR1 (M/T 3907), IBM z13, and IBM z13s. © Copyright International Business Machines Corporation 2020. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . vii Trademarks . viii Preface . ix Authors. ix Now you can become a published author, too! . xi Comments welcome. xi Stay connected to IBM Redbooks . xi Chapter 1. Introduction. 1 1.1 I/O channel overview. 2 1.1.1 I/O hardware infrastructure . 2 1.1.2 I/O connectivity features . 3 1.2 FICON Express . 4 1.3 zHyperLink Express . 5 1.4 Open Systems Adapter-Express. 6 1.5 HiperSockets. 7 1.6 Parallel Sysplex and coupling links . 8 1.7 Shared Memory Communications. 9 1.8 I/O feature support . 10 1.9 Special-purpose feature support . 12 1.9.1 Crypto Express features . 12 1.9.2 Flash Express feature . 12 1.9.3 zEDC Express feature . 13 Chapter 2. Channel subsystem overview . 15 2.1 CSS description . 16 2.1.1 CSS elements .
    [Show full text]
  • IBM System Z9 109 Technical Introduction
    Front cover IBM System z9 109 Technical Introduction Hardware description Software support Key functions Bill Ogden Jose Fadel Bill White ibm.com/redbooks International Technical Support Organization IBM System z9 109 Technical Introduction July 2005 SG24-6669-00 Note: Before using this information and the product it supports, read the information in “Notices” on page vii. First Edition (July 2005) This edition applies to the initial announcement of the IBM System z9 109. © Copyright International Business Machines Corporation 2005. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . vii Trademarks . viii Preface . ix The authors . ix Become a published author . ix Comments welcome. .x Chapter 1. Introduction. 1 1.1 Evolution . 2 1.2 z9-109 server highlights . 3 1.3 zSeries comparisons. 4 1.4 z9-109 server models and processor units . 6 1.5 Upgrades. 6 1.6 Considerations . 7 Chapter 2. Hardware overview . 9 2.1 System frames . 10 2.2 Books . 10 2.3 MCM . 12 2.4 Processor units . 13 2.4.1 PU characterizations. 14 2.5 Memory . 14 2.6 I/O interfaces. 15 2.7 I/O cages and features . 16 2.7.1 Physical I/O connections. 18 2.7.2 Coupling connections . 20 2.7.3 Cryptographic functions . 20 2.8 Time functions. 21 2.8.1 Sysplex Timer . 21 2.8.2 Server Time Protocol (STP) . 22 2.9 Hardware Storage Area . 22 2.10 System control . 22 2.11 HMC and SE .
    [Show full text]
  • TCP/IP and SNA Over FICON SCSI & Ficonover FC FICON Over FC 19
    USOO7702762B1 (12) United States Patent (10) Patent No.: US 7,702,762 B1 Jagana (45) Date of Patent: Apr. 20, 2010 (54) SYSTEM FOR HOST TO-HOST 6,493.825 B1* 12/2002 Blumenau et al. ........... T13,168 CONNECTIVITY USING FICON PROTOCOL 6,499,058 B1* 12/2002 Hozumi ............... ... TO9,225 OVER A STORAGE AREANETWORK 6,636,529 B1 * 10/2003 Goodman et al. ... 370/469 6,654,830 B1 * 1 1/2003 Taylor et al. .................. 71 Of 74 (75)75 Inventor: Venkata R. Jagana, Portland, OR (US) 6,665,7146,658,540 B1* 12/2003 SicolaBlumenau et al. et al....... ........... ... 709/222711,162 (73) Assignee: states insists 6,714,9526,684,209 B2*B1 3/20041/2004 Ito(Shane et al. ........................ at O'707:01 707/9 s s 6,718,347 B1 * 4/2004 Wilson .......... ... TO7,201 c - 6,728,803 B1 * 4/2004 Nelson et al. ................. T10/60 (*) Notice: Subject to any disclaimer, the term of this 6,769,021 B1* 7/2004 Bradley ......... ... TO9.220 patent is extended or adjusted under 35 2003/0236945 A1 12/2003 Nahum ....................... 711 114 U.S.C. 154(b) by 2415 days. OTHER PUBLICATIONS (21) Appl. No.: 09/686,049 Computer Desktop Encyclopedia entry for "SAN” (copyright 1981 (22) Filed1C Oct.cl. 11,1 2000 2004), version 174, 4th Quarter 2004. * cited by examiner (51) Int. Cl. G06F 5/73 (2006.01) E. Early line Pich (52) U.S. Cl. ....................... 709:23.700,246.700,249 (74) Attorney, Agent, or Firm Jason O. Piche 37Of 466 57 ABSTRACT (58) Field of Classification Search ................
    [Show full text]
  • Brocade Fabric OS FICON Administrator's Guide
    53-1003517-04 09 February 2016 Brocade Fabric OS FICON Administrator's Guide Supporting Fabric OS v7.4.0, Fabric OS 7.4.1 © 2016, Brocade Communications Systems, Inc. All Rights Reserved. Brocade, Brocade Assurance, the B-wing symbol, ClearLink, DCX, Fabric OS, HyperEdge, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, Vplane, and Vyatta are registered trademarks, and Fabric Vision is a trademark of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of others. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government. The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs that accompany it. The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
    [Show full text]
  • Z9 BC System Overview Level 04A, April 2009
    System z9 Business Class System Overview SA22-1083-04 Level 04a, April 2009 System z9 Business Class System Overview SA22-1083-04 Level 04a, April 2009 Level 04a, April 2009 Note Before using this information and the product it supports, read the information in “Safety” on page | xiii, Appendix D, “Notices,” on page D-1, and IBM Systems Environmental Notices and User Guide, Z125-5823. Fifth Edition (April 2009) | This edition, SA22-1083-04, applies to the IBM® System z9® Business Class (z9® BC) server. This replaces | SA22-1083-03. Technical changes to the text are indicated by a vertical bar (|) to the left of the change. There may be a newer version of this document in a PDF file available on Resource Link™.Goto http://www.ibm.com/servers/resourcelink and click on Library on the navigation bar. A newer version is indicated by a lowercase, alphabetic letter following the form number suffix (for example: 00a, 00b, 01a, 01b). © Copyright International Business Machines Corporation 2006, 2009. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Level 04a, April 2009 Contents Figures............................ix Tables ............................xi Safety ............................xiii Safety Notices .........................xiii World Trade Safety Information ..................xiii Laser Safety Information .....................xiii Laser Compliance.......................xiii About this Publication .....................xv What is Included in this Publication .................xv
    [Show full text]
  • Oracle's Storage Augments Mainframe Renaissance
    Oracle’s Storage Augments Mainframe Renaissance Mainframe Storage Solutions Remain Best in Class September 2010 Report by Fred Moore, President of Horison Information Strategies, Delivering Continuing Innovations in Mainframe Storage Th Early Mainframes - 1964 System/360 was announced by IBM in April 1964 and is generally considered the first mainframe computer. More than any other computer development effort, the System/360 family of processors enabled companies to affordably integrate all of their data processing applications into a single management information system. The term “360” was actually chosen to show the versatile nature of the computer, which could cover a “360-degree radius” of business applications. At the time, it defined the mainframe as a system that could perform multiple tasks at the same time on one machine and it was now possible to perform one million instructions per second (1 MIPS). The System/360 was also designed to be compatible through all models so that work performed o any model in the 360 series could be ported to any other model. The System/360 could process online, batch and databases at the same time in a multi-programming mode so that the system was literally tailored to the specific customer's jobs. Until the introduction of the System/360 architecture, which introduced many of today’s storage management concepts, accessing large amounts of data had been very time consuming. System/360 greatly improved data storage and retrieval capabilities while providing management with real-time decision-making capabilities for the first time. 1 Mainframes in Transition – 1980s The mainframe was the predominant computing platform from its introduction in the mid-1960s until the mid 1980s.
    [Show full text]
  • IBM Storage Speichertechnologien Unter Der Lupe
    Kurt Gerecke Juni 2012 IBM Storage Speichertechnologien unter der Lupe © 2012 IBM Corporation IBM System Storage Agenda 1 Wir habe ein Geburtstagskind – Historie zum Aufwärmen ..... 2 Disk Technologien 3 Solid State Disks (SSD‘s) 4 Storage Class Memories und Positionierung 5 Millipede und optische Speichertechnologien 6 Tape Technologien 7 Speicherhierarchie 8 Nano-Technologien © 2012 IBM Corporation 1952: IBM Modell 726 erster Bandspeicher • 18.000 Lochkarten • 1.440.000 Characters • 1.44 MB • Acetat Plastikband mit Eisenoxydbeschichtung • 7-Spur Technik (6 x Daten, 1 x Redundanzprüfung) • Datenrate 7.5 Kbit/s, S/L-Geschwindigkeit 1.9 m/s • entwickelt in Phougkeepsie im Zuge der IBM 701 Entwicklung Photo 1951 Prototyp Photo 1952 IBM 726 in Betrieb 720 Meter Bandlänge 100 BPI 1953: IBM Modell 727 (728) • 24.000 Lochkarten • 1.920.000 Characters • 1.92 MB • 7 Spur-Technik 1958: IBM Modell 729 • 50.000 Lochkarten • 4.000.000 Characters • 4 MB • 7 Spur-Technik Bild: 729 Deutsches Museum München Modelle I bis VI • Erstes Tape Laufwerk mit Schreibkontrolle • Einlesen der Zeichen in ein Prüfregister 1961: IBM 7340 Hyper Tape Drives • Kontrolleinheit IBM 7640 • Für Rechner 7074, 7080, 7090 • Doppelte Übertragungsraten vs. 729 • 7-Spur-Technik • Höchste Datenrate WW • 170.000 Zeichen/s • 112.5 Zoll/s Tape Speed • Modelle 1 – 3 • 8 MB später 16 MB 1964: IBM 2401 Magnetbandsystem • speziell für System /360 • 9-Spur Technik • 800 BPI • 20 MB später 40 MB • erster ECC • CRC Cyclic Redundancy Check • Automatic Error Capture & Correction • Basis für spätere ECC‘s Löschschutzring 1970: IBM 3420 Modelle 3,5,7 • System /370 • 3803 Kontroller • 9-Spur-Technik • 800-1600 BPI • 120/200/320 Kilobytes/s •..
    [Show full text]