Injector 1 Injector
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Subject: Supplement to Upper Engine and Fuel Injector Cleaner Label Models: All GM Vehicles Equipped with a Gasoline Engine
7/11/2018 #PIP4753: Supplement To Upper Engine And Fuel Injector Cleaner Label - (Dec 11, 2009) • 2003 GMC Truck Yukon 4WD • MotoLogic 2003 Yukon 4WD Report a problem with this article Subject: Supplement to Upper Engine and Fuel Injector Cleaner Label All GM Vehicles Models: Equipped with a Gasoline Engine The following diagnosis might be helpful if the vehicle exhibits the symptom(s) described in this PI. Condition/Concern: Some service procedures, service bulletins, or PIs may advise to decarbon the engine with GM Upper Engine and Fuel Injector Cleaner to remove valve deposits but the label that is on the back of the bottle does not include any instructions that explain how to use the cleaner. Recommendation/Instructions: If a service procedure, service bulletin, or PI does not include decarboning instructions and the GM Vehicle Care 3 Step Induction Cleaning Kit (E-957-001) is not available, the guidelines below supplement the label and explain how the cleaner can be used to clean the intake valves: Important: Extreme care must be taken not to hydrolock the engine when inducing the cleaner. If too much cleaner is induced at too low of a RPM, or if you force the engine to stall by inducing too much cleaner at once, the engine may hydrolock and bend a connecting rod(s). 1. In a well-ventillated area with the engine at operating temperature, slowly/carefully induce a bottle of GM Upper Engine and Fuel Injection Cleaner into the engine with RPM off of idle enough to prevent it from stalling (typically around 2,000 RPM or so). -
Swampʼs Diesel Performance Tips to Help Remove and Install Power
Injectors-Chips-Clutches-Transmissions-Turbos-Engines-Fuel Systems Swampʼs Diesel Performance Competition Parts For Your Diesel 304-A Sand Hill Rd. La Vergne, TN 37086 Tel 615-793-5573 or (866) 595-8724/ Fax 615-793-5572 Email: [email protected] Tips to help remove and install Power Stroke injectors. Removal: After removing the valve covers and the valve cover gaskets, but before removing any injectors, drain the oil rails by removing the drain plugs inside the valve cover. On 94-97 trucks theyʼre just under where the electrical connectors are on the gasket. These plugs are very tight; give them a sharp blow with a hammer and punch to help break them loose, then use a 1/8" Allen wrench. The oil will drain out into the valve train area and from there into the crankcase. Donʼt drop the plugs down the push rod holes! Also remove one of the plugs on top of each oil rail, (beside where the lines from the High Pressure Oil Pump enter) for a vent to allow air to enter so the oil can drain. The plugs are 5/8”. Inspect the plug O-rings and replace if necessary. If the plugs under the covers leak, it will cause a substantial loss of performance. When removing the injectors, oil and fuel from the passages in the cylinder head drains down through the injector bore into the cylinders. If not removed, this can hydro-lock the engine when cranking. There is a ~40cc dish in the center of each piston. Fluid accumulates in it, as well as in the corner on the outside of the piston between the piston top and the cylinder wall, due to the 45* slope of the cylinder bank. -
Lima 2-8-0 “Consolidation”, Developed for TS2013, by Smokebox
Union Pacific 4000 Class 4884-1 "Big Boy" circa 1948-49 Developed by Smokebox TM for Dovetail Games' Train Simulator © Smokebox 2021, all rights reserved Issue 1 Union Pacific 4000 Class 4884-1 "Big Boy" Steam Locomotive Page 2 Contents Introduction ....................................................................................................................................................... 7 32- and 64-bit TS ................................................................................................................................................ 7 Expert or Simple Controls mode, HUD and Automatic Fireman ....................................................................... 7 "All-in-one" .................................................................................................................................................... 7 Standard TS Automatic Fireman .................................................................................................................... 8 F4 HUD ........................................................................................................................................................... 8 High Detail (HD) and Standard Detail (SD) ........................................................................................................ 8 Recommended Settings ..................................................................................................................................... 9 Cab Layout ...................................................................................................................................................... -
Bryan® Boilers
Form No. 7510 (Rev. 6/05) Bryan “Flexible Water Tube” AB Series Steam & Water Boilers 900,000 to 3,000,000 BTUH Forced draft gas, oil or dual fuel fi red Water Boiler AB120-W-FDGO Steam Boiler AB250-S150-FDG BRYAN® BOILERS Originators of the “Flexible Water Tube” design Low initial cost, high operating effi ciency deliver substantial return on investment • True “fl exible water tube” design guaranteed shock free F • Longer lasting with better A M performance J C • Full fi ve sq ft of heating K surface per BHP G Quality Construction Features: A. Water side or steam side interior ac cessible for B clean out and inspection, front and rear open ings, D upper and lower drums. H B. Large volume water leg downcomers promote rapid internal circulation, temperature equalization and L effi cient heat transfer. I C. Boiler tube and furnace area access panels: heavy E gauge steel casing with 2" high-temperature ceramic fi ber insulation, bolted and tightly sealed to boiler frame. D. Flame observation port in access door at rear of boiler. E. Single side access; combustion chamber, tubes and burner head are completely accessible from one side simplifying K. Bryan bent water tubes maintenance and minimizing fl oor space. are fl exible, individually F. Minimum sized fl ue vent. replaceable without welding or rolling. Never more than G. Control panel: all controls installed with connections to two tube confi gurations. terminal strip. L. Pressurized design H. Forced draft, fl ame retention head type burner. Effi cient fi rebox with internal water- combustion of oil or gas, plus quiet operation. -
Interstate Commerce Commission Washington
INTERSTATE COMMERCE COMMISSION WASHINGTON REPORT NO. 3483 wTRAL OF GSOLTIA RAILWAY COMPANY IN RE ACCJ DENT AT MCINTIRE , OA.f ON ATJVAJS: 29, 1952 Report No. 3483 SUMMARY Date: August 29, 1952 Rail road: Central of Georgia Location: Mcli-tyre, G&. Kino oi' accident: Boiler explosion Train Number: Gordon svnitch local Locomotive number: g 00 Conn 1st: Ltjht, at time of accident Speed: Standing Operation: Local si\ri telling Track: On house track Tire : 1:20 p. m, g, nidl!-|c3: 2 Injured Cause : Overheated crown sheet result ing from low water INTERSTATE CONNERCE COMMISSION REPORT NO. 3483 IN THE NATTER OP MAKING ACCIDENT INVESTIGATION UNDER THE LOCOMOTIVE INSPECTION ACT OF FEBRUARY 17, 1911, AS AMENDED CENTRAL OF GEORGIA RAILWAY November 10, 1952 Acoident (boiler explosion) at Hclntyre, Ga,, on August 29, 1952, caused, by overheated, crown sheet due to low water. REPORT OF THE COMMISSION1 PATTERSON, Commissioner: On August ?9, 1952, about 1:10 p.m., at Mclntyre, Ga., the boiler of Central of Georgia Railway locomotive 6?S exploded while the locomotive was standing on the house track. The engi neer and. fireman were seriously injured. lUnder authority of sect: on 17 (2) of the Interstate Commerce Act the above-entitled proceeding was referred by the Commission to Commissioner Patterson for consideration and disposition. - 3 - DESCRIPTION OF ACCIDENT Central of Georgia Railway locomotive 629 wan placed in service at Gordon, Ga,, at 7:30 a.m., August 29, 1952, on the Gordon switch local which regularly performs switching service at four kaolin mines at and between Gordon ana Mclntyre, Ga,, a station 8.9 miles ca?t of Gordon, After switching at two mines the train proceeded, without any known unusual incident, one mile to Nolntyre where the train, consisting of 3 loaded ana 4 empty cars, was placed-on a siding and the locomotive moved to the house track. -
FWZ Series Boiler Is a Cast Iron Oil-Fired Water Boiler Designed for Use in Closed Forced Circulation Heating Systems
D ESIGNED TO L EAD FWZ Series Oil-Fired Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler Models: • FWZ060 • FWZ080 WARNING: Improper installation, adjustment, alteration, service or • FWZ100 maintenance can cause property • FWZ130 damage, injury, or loss of life. For assistance or additional • FWZ160 information, consult a qualified installer, service agency or the oil supplier. Read these instructions carefully before installing. Manufacturer of Hydronic Heating Products P.O. Box 14818 3633 I. Street Philadelphia, PA 19134 www.crownboiler.com1 2 WARNINGS FOR THE HOMEOWNER FOLLOW ALL INSTRUCTIONS and warnings unless alarms or other safeguards are in place to printed in this manual and posted on the boiler. prevent such damage INSPECT THE BOILER, BURNER AND DO NOT BLOCK AIR FLOW into or around the CONTROLS ANNUALLY. To keep your boiler safe boiler. Insufficient air may cause the boiler to and efficient, have a service technician follow the produce carbon monoxide or start a fire. Service checklist near the end of this manual. KEEP FLAMMABLE LIQUIDS AWAY from the IF YOU ARE NOT QUALIFIED to install or service boiler, including paint, solvents, and gasoline. boilers, do not install or service this one. The boiler may ignite the vapors from the liquids causing explosion or fire. THE BOILER MAY LEAK WATER at the end of its useful life. Be sure to protect walls, carpets, KEEP CHILDREN AND PETS away from hot and valuables from water that could leak from the surfaces of the boiler, boiler piping, and vent pipe. boiler. CARBON MONOXIDE (CO) is an odorless, deadly PROTECT YOUR HOME IN FREEZING gas that may be introduced into your home by WEATHER. -
Compressible Flows for Fluidic Control in Microdevices
COMPRESSIBLE FLOWS FOR FLUIDIC CONTROL IN MICRODEVICES by Dustin S. Chang A dissertation submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy (Chemical Engineering) in The University of Michigan 2010 Doctoral Committee: Professor Mark A. Burns, Chair Professor Robert M. Ziff Associate Professor Luis P. Bernal Associate Professor Michael Mayer © Dustin S. Chang 2010 To my mom and dad, Sweson and Chaohui, and my grandparents, Po-High and Peyuk … Thank you for all your sacrifices. ii ACKNOWLEDGEMENTS To the casual observer, a doctoral thesis may appear to be the product of a single dedicated—albeit misguided—individual after multiple years of toil. Anyone that has survived the experience will most assuredly tell you that he could not have done it without the many people who supported him along the way. Beginning long before graduate school, my family has been a constant source of encouragement, well-meaning criticism, and material support. I am hugely grateful for my aunts and uncles who never failed to go the extra mile in taking care of me, teaching me, and challenging me to improve. Aunt Hsueh-Rong, Aunt Nancy, Aunt Chao-Lin, Uncle Jeff, Aunt Tina, and Uncle Ming ... Thank you for your love. The only people potentially deserving greater appreciation than these are my mother and father and my grandparents. I have no doubt that none of my meager accomplishments would have been possible without your prayers and unconditional support, both moral and financial. I also have no doubt that all of the aforementioned people are infinitely more enamored with the idea of a Ph.D. -
Local Heat Transfer in a Calorimetric Tube with Water Injection
processes Article An Experimental Investigation of Water Vapor Condensation from Biofuel Flue Gas in a Model of Condenser, (2) Local Heat Transfer in a Calorimetric Tube with Water Injection Robertas Poškas 1,*, Arunas¯ Sirvydas 1, Vladislavas Kulkovas 1, Hussam Jouhara 2 , Povilas Poškas 1, Gintautas Miliauskas 3 and Egidijus Puida 3 1 Nuclear Engineering Laboratory, Lithuanian Energy Institute, Breslaujos 3, LT-44403 Kaunas, Lithuania; [email protected] (A.S.); [email protected] (V.K.); [email protected] (P.P.) 2 Heat Pipe and Thermal Management Research Group, College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge UB8 3PH, UK; [email protected] 3 Department of Energy, Faculty of Mechanical Engineering and Design, Kaunas University of Technology, Studentu 56, LT-51424 Kaunas, Lithuania; [email protected] (G.M.); [email protected] (E.P.) * Correspondence: [email protected]; Tel.: +37-037401893 Abstract: In order for the operation of the condensing heat exchanger to be efficient, the flue gas temperature at the inlet to the heat exchanger should be reduced so that condensation can start from the very beginning of the exchanger. A possible way to reduce the flue gas temperature is the injection of water into the flue gas flow. Injected water additionally moistens the flue gas and increases its level of humidity. Therefore, more favorable conditions are created for condensation and Citation: Poškas, R.; Sirvydas, A.; heat transfer. The results presented in the second paper of the series on condensation heat transfer Kulkovas, V.; Jouhara, H.; Poškas, P.; indicate that water injection into the flue gas flow drastically changes the distribution of temperatures Miliauskas, G.; Puida, E. -
Crankshaft Position for Fuel Injector Adjustment and Valve Lash Setting
Crankshaft Position for Fuel Injector Adjustment and Valve Lash Setting Part Number - S/N- SBJ1-UP Part Number - S/N- T2X1-UP Part Number - S/N- SBG1-UP Part Number - S/N- RMS1-UP Part Number - S/N- LLB1-UP Part Number - S/N- LLE1-UP Part Number - S/N- LLF1-UP Part Number - S/N- LLA1-UP Part Number - S/N- PES1-UP Part Number - S/N- SBM1-UP Part Number - S/N- LLC1-UP Part Number - S/N- C8E1-UP Part Number - S/N- R1A1-UP Part Number - S/N- C8K1-UP Part Number - S/N- SBK1-UP Table 1 Counterclockwise Rotation (Standard)from the Flywheel End of the Engine Cylinders to Check/Adjust Engine Correct Stroke For No. 1 Piston At Exhaust Valves Inlet Valves Injectors Top Center Position (1) Compression 1-2-6-8 1-2-3-7 2-3-4-7 3508 Exhaust 3-4-5-7 4-5-6-8 1-5-6-8 1-3-6-7-10-12 Compression 1-4-5-6-9-12 2-4-5-8-9-11 3512 2-4-5-8-9-11 1-3-6-7-10-12 Exhaust 2-3-7-8-10-11 1-2-5-7-8-12- 1-2-3-4-5-6-8-9 3-4-6-9-10-11- Compression 13-14 15-16 3516 3-4-6-9-10-11 7-10-11-12-13- 1-2-5-7-8-12- Exhaust -15-16 14-15-16 13-14 ( 1 ) Put the No. 1 Piston at the top center (TC) position and identify the correct stroke. -
“Flexible Water Tube” EB Series Steam & Water Boilers
Form No. 8100 (1/06 ) Bryan “Flexible Water Tube” EB Series Steam & Water Boilers 3,200,000 to 10,000,000 BTUH Forced draft gas, oil or dual fuel fi red Water Boiler EB-200-W-FDGO Steam Boiler EB-75-S150-FDG BRYAN® BOILERS Originators of the “Flexible Water Tube” design Low initial cost, reliable operating effi ciency deliver substantial return on investment • True “fl exible water tube” design • High quality steam for heat F or process • Pressurized fi ring for maximum M performance J N Quality Construction Features: D G A K A. Water side or steam side interior ac cessible for clean out and inspection, front and rear B C open ings, upper and lower drums. H D L B. Large volume water leg down comers pro- mote rapid internal circulation, temperature equalization and effi cient heat transfer. I C. Boiler tube and furnace area access panels: E heavy gauge steel casing with 2 high tem- perature ceramic fi ber and insulation, bolted and tightly sealed to boiler frame. D. Flame observation port at rear of boiler. E. Single side access; combustion chamber, tubes and burner head are completely accessible from one side simplifying maintenance and minimizing fl oor space. L. Internal water-cooled F. Minimum sized fl ue vent. furnace with low heat G. Control panel: all controls installed with connections release rate. to terminal strip. M. Steam boilers with H. Forced draft, fl ame retention head type burner. Effi - extra large drum with high cient combustion of oil or gas, plus quiet operation. steam release area ensure stable water level and dry I. -
Detroit Diesel Injector Timing Chart
Detroit diesel injector timing chart Continue 101 S. Hanley Rd., St. Louis, MO 63105 Founded as part of General Motors' diesel division in 1938, Detroit Diesel Engines found use in a variety of applications, including large trucks, agricultural equipment and industrial use. Detroit Diesel is currently a subsidiary of Daimler Trucks. Detroit's popular diesel lines include the DD Series, as well as 53, 60, 71 and MBE-series engines. Identification depends on the definition of the model and the year the year is found on the engine ID tag. Find the Detroit diesel engine identification tag. You will usually find an identification tag on the valve cover at the top of the engine, or in the vicinity, either on the left or right of it. The style of ID tags has changed over the years, but the information found on it essentially remains the same. Find the engine model number on the ID tag. According to the Wisconsin Transportation Identification Bureau, the identification tag contains model designation, production unit serial number and model year, as well as other information. You will find a model of the Detroit diesel engine headlined by a series of engines, usually above the serial unit number. Determine the year of production. Usually you will find a year of production in the top right corner of the engine ID tag. In order to read the ID label, it may be necessary to clean it with a rag and clean the solvent. The typical color for Detroit Diesel engines is green, although some engine models are painted light blue, such as the Model 60, or black, as in the case of the DD13 and 15 models. -
Pressure and Piezometry (Pressure Measurement)
PRESSURE AND PIEZOMETRY (PRESSURE MEASUREMENT) What is pressure? .......................................................................................................................................... 1 Pressure unit: the pascal ............................................................................................................................ 3 Pressure measurement: piezometry ........................................................................................................... 4 Vacuum ......................................................................................................................................................... 5 Vacuum generation ................................................................................................................................... 6 Hydrostatic pressure ...................................................................................................................................... 8 Atmospheric pressure in meteorology ...................................................................................................... 8 Liquid level measurement ......................................................................................................................... 9 Archimedes' principle. Buoyancy ............................................................................................................. 9 Weighting objects in air and water ..................................................................................................... 10 Siphons ...................................................................................................................................................