Radiation Safety Manual Revision Date: September 2016 Page 48 Appendix D: Abbreviations, Conversions, Examples and Formulas Abbreviations ALARA – As Low As Reasonably Achievable Bq – Becquerel Ci – Curie cpm – counts per minute DRS – Division of Research Safety dpm – disintegration per minute GM – Geiger-Mueller Gy – Gray (unit of absorbed dose) HPLC – High Performance Liquid Chromatography IEMA – Illinois Emergency Management Agency (formerly Illinois Department of Nuclear Safety (IDNS)) LDPE – low density poly ethylene LSC – liquid scintillation count or liquid scintillation counter mCi – millicurie NaI – sodium iodide PI – Principal Investigator μCi – microcurie R – Roentgen Rad – radiation absorbed dose Rem – Roentgen equivalent man Sv – Sievert Conversions 2.22 x 106 dpm = 1 microcurie 1000 mirocuries = 1 millicurie 1000 millicuries = 1 Curie 1 Bequerel = 1 disintegration per second (dps) 37 GBq = 1 Ci = 109 disintegrations per second (dps) Formulas and examples For determination of meter or wipe survey results, use: Activity (dpm) = (gross count rate – background count rate) instrument efficiency Example: The GM meter response on a benchtop scan was 150 cpm. The background count rate was 40 cpm. Radiation Safety Manual Revision Date: September 2016 Page 48 Abbreviations, Conversions, Examples, and Formulas Appendix D For P-32, the GM efficiency is approximately 50%. What is the amount of activity on the benchtop? Activity (dpm) = (150 cpm – 40cpm) = 220 dpm (0.50) A survey instrument’s efficiency can be determined for an individual radionuclide using a known standard (decay-corrected, if necessary) of the radionuclide. The standard is counted in a fixed geometry and the instrument count rate observed. The efficiency is then determined by the formula: Efficiency (%) = (gross count rate – background count rate) x 100 Activity of standard (dpm) Radiation Safety Manual Revision Date: September 2016 Page 49 .
Recommended publications
  • AFRRI Biodosimetry Worksheet
    Armed Forces Radiobiology Research Institute Biodosimetry Worksheet (Medical Record of Radiation Dose, Contamination, and Acute Radiation Sickness Response) Reporting Authority (person(s) creating this page of the report) Last name: First name: Country of origin: Unit: Phone: Fax: Email: Location: Date (yymmdd): Time: Casualty Last name: First name: Rank: Country of origin: Parent unit: Parent unit location: Parent unit phone: Unit e-mail: Unit fax: Casualty location: History of presenting injury (conventional and/or radiation): History of previous radiation exposure: Past medical history (general): Medical countermeasures (e.g., antiemetics, transfusion), specify: Administered (where, when, route): Exposure conditions Date of exposure (yymmdd): Exposure location: Time of exposure: Weather conditions (at time of exposure): Exposure results Describe incident: External exposure overview Contamination overview Body exposure: Total Partial Uncertain External contamination: Yes No Shielding confounder: Yes No Internal contamination: Yes No Contaminated wound: Yes No If wound(s) are radiation contaminated, please provide details here: Biodosimetric assays overview Sampling date, time Estimated time Dose Reference radiation quality yymmdd (time) post-exposure (h) (Gy) and dose rate (Gy/min) Time onset of vomiting: Lymphocyte counts or depletion kinetics: Urine bioassay: Cytogenetic biodosimetry: Other: ARS response category overview (maximum grading 0-4; see pages 4 through 6 for guidance) N: C: G: H: = RC: days after radiation exposure: AFRRI
    [Show full text]
  • Uranium Fact Sheet
    Fact Sheet Adopted: December 2018 Health Physics Society Specialists in Radiation Safety 1 Uranium What is uranium? Uranium is a naturally occurring metallic element that has been present in the Earth’s crust since formation of the planet. Like many other minerals, uranium was deposited on land by volcanic action, dissolved by rainfall, and in some places, carried into underground formations. In some cases, geochemical conditions resulted in its concentration into “ore bodies.” Uranium is a common element in Earth’s crust (soil, rock) and in seawater and groundwater. Uranium has 92 protons in its nucleus. The isotope2 238U has 146 neutrons, for a total atomic weight of approximately 238, making it the highest atomic weight of any naturally occurring element. It is not the most dense of elements, but its density is almost twice that of lead. Uranium is radioactive and in nature has three primary isotopes with different numbers of neutrons. Natural uranium, 238U, constitutes over 99% of the total mass or weight, with 0.72% 235U, and a very small amount of 234U. An unstable nucleus that emits some form of radiation is defined as radioactive. The emitted radiation is called radioactivity, which in this case is ionizing radiation—meaning it can interact with other atoms to create charged atoms known as ions. Uranium emits alpha particles, which are ejected from the nucleus of the unstable uranium atom. When an atom emits radiation such as alpha or beta particles or photons such as x rays or gamma rays, the material is said to be undergoing radioactive decay (also called radioactive transformation).
    [Show full text]
  • Appendix B: Recommended Procedures
    Recommended Procedures Appendix B Appendix B: Recommended Procedures Appendix B provides recommended procedures for tasks frequently performed in the laboratory. These procedures outline acceptable methods for meeting radiation safety requirements. The procedures are generic in nature, allowing for the diversity of research facilities, on campus. Contamination Survey Procedures Surveys are performed to monitor for the presence of contamination. Minimum survey frequencies are specified on the radiation permit. The surveys should be sufficiently extensive to allow confidence that there is no contamination. Common places to check for contamination are: bench tops, tools and equipment, floors, telephones, floors, door handles and drawer pulls, and computer keyboards. Types of Contamination Removable contamination can be readily transferred from one surface to another. Removable contamination may present an internal and external hazard because it can be picked up on the skin and ingested. Fixed contamination cannot be readily removed and generally does not present a significant hazard unless the material comes loose or is present large enough amounts to be an external hazard. Types of Surveys There are two types of survey methods used: 1) a direct (or meter) survey, and 2) a wipe (or smear) survey. Direct surveys, using a Geiger-Mueller (GM) detector or scintillation probe, can identify gross contamination (total contamination consisting of both fixed and removable contamination) but will detect only certain isotopes. Wipe surveys, using “wipes” such as cotton swabs or filter papers counted on a liquid scintillation counter or gamma counter can identify removable contamination only but will detect most isotopes used at the U of I. Wipe surveys are the most versatile and sensitive method of detecting low-level removable contamination in the laboratory.
    [Show full text]
  • Digital Radiation Monitor Is a Health and Safety Instrument That Measures Alpha, Digital Radiation Monitor Beta, and Gamma Radiation
    1 Introduction The Digital Radiation Monitor is a health and safety instrument that measures alpha, Digital Radiation Monitor beta, and gamma radiation. With the Digital Radiation Monitor, you can: • Monitor possible radiation exposure while working near radionuclides (Order Code DRM-BTD) • Ensure compliance with regulatory standards Contents • Check for leakage from X-ray machines and other sources • Screen for environmental contamination or environmental sources of 1 Introduction ............................................................................................................. 2 radioactivity How the DRM Detects Radiation ................................................................. 2 • Connect the Digital Radiation Monitor to a computer or data logger to record 2 Features ................................................................................................................... 3 and tabulate your data The Display................................................................................................... 3 The Switches ................................................................................................4 This manual gives complete instructions for using the Digital Radiation Monitor and The Detector..................................................................................................5 procedures for common applications. The Ports....................................................................................................... 5 3 Operation................................................................................................................
    [Show full text]
  • Measuring Radioactivity
    Health Physics Society Public Education Committee Fact Sheet MEASURING RADIOACTIVITY Because ionizing radiation cannot be detected with our human senses, we use various types of instruments and radiation detectors to measure the amount of radiation present. We usually measure both the amount of radioactivity in a radioisotope source, and the ionizing radiation field density being emitted by the source. We define radioactivity as the number of atoms which decay (disintegrate) in a radioisotope sample in a given period of time. The base unit is the Becquerel (Bq) or one disintegration per second (dps). This number is very small and therefore, not very useful. For this reason we use the Curie (Ci) which is 37 billion Bq. Because we often use very large or very small numbers when discussing radioactivity, we use a series o f prefixes which express multiples of 1000. The following table shows some of these prefixes: milli (m) = 1/1,000 kilo (k) = times 1,000 micro (u) = 1/1,000,000 mega (M) = times 1,000,000 nano (n) 1/1,000,000,000 giga (G) times 1,000,000,000 Pico (P) 1/1,000,000,000,000 tera (T) times 1,000,000,000,000 Using the table, a mCi = 1/1000 of a Curie and a GBq 1,000,000,000 Becquerels. To put this in perspective, a normal home smoke detector contains a small sealed source of about 10 uCi (370,000 Bq) of radioactivity. Ionizing radiation fields are expressed in units of Roentgens (R) which is equivalent to the number of atoms of a gas which are ionized.
    [Show full text]
  • The International Commission on Radiological Protection: Historical Overview
    Topical report The International Commission on Radiological Protection: Historical overview The ICRP is revising its basic recommendations by Dr H. Smith Within a few weeks of Roentgen's discovery of gamma rays; 1.5 roentgen per working week for radia- X-rays, the potential of the technique for diagnosing tion, affecting only superficial tissues; and 0.03 roentgen fractures became apparent, but acute adverse effects per working week for neutrons. (such as hair loss, erythema, and dermatitis) made hospital personnel aware of the need to avoid over- Recommendations in the 1950s exposure. Similar undesirable acute effects were By then, it was accepted that the roentgen was reported shortly after the discovery of radium and its inappropriate as a measure of exposure. In 1953, the medical applications. Notwithstanding these observa- ICRU recommended that limits of exposure should be tions, protection of staff exposed to X-rays and gamma based on consideration of the energy absorbed in tissues rays from radium was poorly co-ordinated. and introduced the rad (radiation absorbed dose) as a The British X-ray and Radium Protection Committee unit of absorbed dose (that is, energy imparted by radia- and the American Roentgen Ray Society proposed tion to a unit mass of tissue). In 1954, the ICRP general radiation protection recommendations in the introduced the rem (roentgen equivalent man) as a unit early 1920s. In 1925, at the First International Congress of absorbed dose weighted for the way different types of of Radiology, the need for quantifying exposure was radiation distribute energy in tissue (called the dose recognized. As a result, in 1928 the roentgen was equivalent in 1966).
    [Show full text]
  • Laboratoire National Henri Becquerel Ccri(I)/01-05 Dimri/Lnhb/Bc/01-146 30/03/01
    BUREAU NATIONAL DE MÉTROLOGIE COMMISSARIAT À L'ÉNERGIE ATOMIQUE LABORATOIRE NATIONAL HENRI BECQUEREL CCRI(I)/01-05 DIMRI/LNHB/BC/01-146 30/03/01 BUREAU NATIONAL DE METROLOGIE Laboratoire National Henri Becqurel (BNM-LNHB) Laboratoire Central des Industries Electriques (BNM-LCIE) DOSIMETRY OF PHOTONS AND CHARGED PARTICLES Progress Report 2000-2001 B.Chauvenet Participation in the CCRI K4 key comparison on calibration factors of ionisation chambers in terms of absorbed dose to water for 60Co photons Comparison of standards of absorbed dose to water for high-energy photon beams with METAS A comparison was carried out with METAS in October 2000. This comparison dealt with air kerma and absorbed dose to water standards in 60Co beams, and absorbed dose to water standards for high-energy x rays from accelerators (6 MV, 12 MV and 20 MV). The comparison was carried out in BNM-LNHB beams (60Co and Saturne 43 accelerator), with transfer chambers from METAS. Results are under analysis. Comparison of standards of absorbed dose to water for high-energy photon beams with NRC This comparison was carried out in October 1998. The results were discussed and analysed, and will be presented in a paper which has been submitted to “Physics in Medicine and Biology”. EUROMET projects Participation in EUROMET Contact Persons meetings for the preparation of CMC tables. The laboratory will participate in the proposed project of METAS on quality factors for high-energy photon beams. Absorbed dose to graphite by calorimetry The realisation of a new graphite calorimeter is under study to replace the present one built in 1984.
    [Show full text]
  • Chapter 2 Radiation Safety Manual Revision 1 Principles of Radiation Safety 6/1/2018
    The University of Georgia Chapter 2 Radiation Safety Manual Revision 1 Principles of Radiation Safety 6/1/2018 CHAPTER 2 PRINCIPLES OF RADIATION SAFETY 1.0 UNITS OF RADIATION DOSE 1.1 Historical Units In 1896, x-rays were discovered by Wilhelm Roentgen. The Roentgen is unit of measurement for the exposure of x-rays and gamma rays. It is defined as the electric charge freed by such radiation in a specified volume of air divided by the mass of that air. Radioactivity was discovered by Henri Becquerel. Radioactivity refers to the amount of radiation released when an element spontaneously emits energy as a result of the decay of its unstable atoms. The Becquerel is a unit used to measure radioactivity, and stands for 1 disintegration per second. The Curie is a unit of radioactivity equal to 3.7 X 1010 disintegrations per second and was first used, but being such a large unit was replaced by the Becquerel. The Curie is named for Pierre Curie, Marie Curie’s husband and co- discoverer of radium. After his accidental death, she continued their work. For some time, no one realized that radiation could cause harmful effects. It was recognized very soon that x-rays could be used in medical diagnosis, and early radiologists received large doses of radiation. Many of these radiologists later suffered severe injuries due to overexposure (radiation effects may appear years after exposure). The first unit of dose was the erythema dose. This was the amount of x-radiation which would barely cause reddening of the skin. It was not a very satisfactory unit of dose, but indicates the early recognition by some scientists that radiation exposure can be harmful and should be limited.
    [Show full text]
  • Radiation Glossary
    Radiation Glossary Activity The rate of disintegration (transformation) or decay of radioactive material. The units of activity are Curie (Ci) and the Becquerel (Bq). Agreement State Any state with which the U.S. Nuclear Regulatory Commission has entered into an effective agreement under subsection 274b. of the Atomic Energy Act of 1954, as amended. Under the agreement, the state regulates the use of by-product, source, and small quantities of special nuclear material within said state. Airborne Radioactive Material Radioactive material dispersed in the air in the form of dusts, fumes, particulates, mists, vapors, or gases. ALARA Acronym for "As Low As Reasonably Achievable". Making every reasonable effort to maintain exposures to ionizing radiation as far below the dose limits as practical, consistent with the purpose for which the licensed activity is undertaken. It takes into account the state of technology, the economics of improvements in relation to state of technology, the economics of improvements in relation to benefits to the public health and safety, societal and socioeconomic considerations, and in relation to utilization of radioactive materials and licensed materials in the public interest. Alpha Particle A positively charged particle ejected spontaneously from the nuclei of some radioactive elements. It is identical to a helium nucleus, with a mass number of 4 and a charge of +2. Annual Limit on Intake (ALI) Annual intake of a given radionuclide by "Reference Man" which would result in either a committed effective dose equivalent of 5 rems or a committed dose equivalent of 50 rems to an organ or tissue. Attenuation The process by which radiation is reduced in intensity when passing through some material.
    [Show full text]
  • THESIS VERIFICATION of BACKGROUND REDUCTION in a LIQUID SCINTILLATION COUNTER Submitted by Marilyn Alice Magenis Department of E
    THESIS VERIFICATION OF BACKGROUND REDUCTION IN A LIQUID SCINTILLATION COUNTER Submitted by Marilyn Alice Magenis Department of Environmental and Radiological Health Sciences In partial fulfillment of the requirements For the Degree of Master of Science Colorado State University Fort Collins, Colorado Summer 2013 Master’s Committee: Advisor: Alexander Brandl Thomas E. Johnson John Volckens John Harton ABSTRACT VERIFICATION OF BACKGROUND REDUCTION IN A LIQUID SCINTILLATION COUNTER A new method for subtraction of extraneous cosmic ray background counts from liquid scintillation detection has been developed by HidexTM. The method uses a background counter located beneath the liquid scintillation detector, the guard, to account for background signals. A double to triple coincidence counting methodology is used to reduce photomultiplier noise and to quantify quench. It is important to characterize the interactions from background in any new system. Characterizing interactions in the instrument will help to verify the accuracy and efficiency of the guard by determining the noise cancellation capabilities of the liquid scintillation counter. The liquid scintillation counter and guard detector responses were modeled using MCNP for the expected cosmic ray interactions at the instrument location and altitude in Fort Collins, CO. Cosmic ray interactions in the detector are most relevant to examine because of their predominance due to the higher elevation in Fort Collins. The cosmic ray interactions that are most important come from electron, positron, and gamma interactions. The expected cosmic ray interactions from these particles were modeled by using a cosmic ray library that determines the cosmic rays that are most likely to occur at an altitude of 2100 meters.
    [Show full text]
  • ACUTE RADIATION SYNDROME: Diagnosis and Treatment
    ACUTE RADIATION SYNDROME: Diagnosis and Treatment Badria Al Hatali, MD Medical Toxicologist Department of Environmental and Occupational Health MOH - Oman Objectives Provide a review of radiation basics and acute radiation sickness Discuss diagnostic tools and triage tools for Acute Radiation Syndromes Discuss management of Acute Radiation Syndromes Energy traveling over a distance as Waves Particles • Gamma rays • Alpha • X-rays • Beta • Radio waves • neurons Non-ionizing vs Ionizing Radiation • High energy • Low energy • Removes orbital electrons • Does not remove orbital from atoms > DNA electrons from atom damage Radioactive Decay Process to Remove excess energy from atomic nuclei Nuclei emit rays or particles to decrease nuclear energy Radioactive materials have unstable nuclei with excess energy Ionizing Radiation Dose • Radiation absorb dose (RAD): the amount of energy absorbed by the body. 1 cGy = 0.01 J/kg (USA) • Gray (Gy): expressed as absorbed energy per unit mass of tissue. 100 rad =100 cGy =1 J/kg (SI) • Roentgen Equivalent Man (REM) relates the absorbed dose in human tissue to the effective biological damage of the radiation (USA) • Sievert (Sv): the absorbed dose in human tissue to the effective biological damage of the radiation (SI) Radioactivity Biological And Effective Half-lives Biological half-life is the time to remove half of radioactive element from body Effective half-life is the combined effect of radioactive decay & biological elimination Effective half-life is always shorter than either physical or biological half-lives Biological Effects of Ionizing Radiation Direct damage Chromosome Other biochemical E.g. alpha and beta particles Indirect damage Chemical changes due to radiolysis of water in cell E.g.
    [Show full text]
  • Ranger Operating Manual
    INTERNATIONAL ® S.E. International, Inc. P.O. Box 39, 436 Farm Rd. Summertown, TN 38483 USA 1.800.293.5759 | 931.964.3561 | Fax: 1.931.964.3564 www.seintl.com | [email protected] Contents Chapter 1: Introduction 3 Preferences 14 How The unit Detects Radiation 3 Using the Data Logging Feature 14 Precautions 3 Show Grid 15 Observer USB Chart Screen 15 Chapter 2: Features 4 The X Axis 15 The LCD Display 4 The Y Axis 15 Indicators 4 Observer USB Meter Screen 15 The Buttons 5 Enable Alarm 15 Power Button 5 Zero 15 Alarm Button 5 Units/Echo Display 15 Count Button 5 Cal Panel (Calibration Panel) 16 Audio Button 5 Calibration Information 16 Menu Button 5 Applied Isotope 16 Backlight Button 5 Alarm Settings 16 Mode Button 6 Preset Counting Time (min) 16 The Detector 6 Data Logging Settings 16 USB Jack 6 Backlight On Time 16 Lanyard 6 Auto-Averaging 16 Xtreme Boot 6 Audio Settings 16 Chapter 3: Operation 7 Starting The unit 7 Chapter 8: Built in Isotope Efficiencies 17 Units of Measurement 7 Built in Isotope Efficiencies 17 Display Update 7 Decay 17 Maximum level 7 Selecting a Built-In Isotope Efficiency 17 Response Time (Autoaveraging) 7 Adding A Custom Isotope Efficiency 17 Autoranging 8 Operating in Dose/Rate Modes 8 Chapter 9: Observer USB Calibration Software 18 Using The Alarm 8 General Discussion of Calibration 18 Operating in Count Mode 9 Pulse Based Pre-Calibration 18 How To Take A Timed Count 9 Efficiency Calibration 19 Using Dose/Rate Modes While Timer is On 9 Exposure Rate Calibration 20 The Menu 10 Menu Options 10 Chapter 10: Troubleshooting 22 Setting the Internal Clock 10 Interfacing with an External Device 10 Chapter 11: Basics of Taking Measurements 23 How to Detect Background Radiation 23 Chapter 4: Common Procedures 11 How To Survey a Surface 23 Establishing the Background Count 11 How to Perform a General Survey 23 Environmental Area Monitoring 11 How to Determine Alpha, Beta, or Gamma source.
    [Show full text]