Science Lab Equipment You Should Know the Name of Each Piece and Its Basic Use

Total Page:16

File Type:pdf, Size:1020Kb

Science Lab Equipment You Should Know the Name of Each Piece and Its Basic Use Science Lab Equipment You should know the name of each piece and its basic use. The volumetric flask is used to The rounded make solutions. It Volumetric flask For exact Pipet bottom of the Florence flask has a precise volume florence flask graduation line in measurement makes it ideal the neck of the s of liquids. There are several for boiling flask. A solute is Pipet on the styles of fillers liquids. It also placed into the left is a used to draw Pipet filler makes this flask, then the Volumetric liquids into a pipet. flask easy to solvent is used to pipet. It has HHS chemistry tip over when bring the total only one students use a sitting on the volume up to the graduation for standard pipet lab table. graduation. delivering one bulb, described in exact volume. lab techniques Pipet on the below. right is a Mohr pipet. It has Never draw a liquid Used to make Beakers are graduations into a pipet with accurate the most Graduated for delivering your mouth. measurements of versatile cylinder any number of liquid volumes. The glassware in exact bumper ring on the lab and volumes. Beaker larger cylinders is to can be used prevent breakage if for just about Filter flask Erlenmeyer tipped over. Keep it anything. The flask near the top. Used in The Erlenmeyer volume conjunction flask is the most graduations with a vacuum common flask in on beakers connection to the HHS chemistry should be a water faucet lab. It is used to used only for to speed up contain reaction "ballpark" filtration. solutions. estimates. This dish is Mortar and used to Pestle Test tube recover A watch glass can Used to hold test holder dissolved Used to grind Evaporating dish be used like an Watch glass tubes for short solids by solids into evaporating dish for periods of "gentle" evaporation. powers. very small amounts heating. While it can of liquid. It can also be heated, it be used to cover should not be beakers. used for "strong" Wash bottle heating. Filter funnel When lined When with filter Used for rinsing attached to When attached to paper, used to Support ring Utility clamp solids out of a the ring stand, the ring stand, this filter container when this iron ring is clamp is used to suspended filtering. used to hold a large test solids from a support tube or Florance liquid. glassware flask above the lab above the lab table. table. Used to Crucibles are Crucible Hose clamps used as a Crucible and transfer solids These tongs are tongs Chemical spoon container cover from their Used to close hoses used for picking up when original by pinching them crucibles and something container to a together. crucible covers requires scale for only. "strong" weighing. heating. Dessicators are used to provide a dry environment for a Desiccator Wire gauze crucible or substance to cool down. This is critical in quantitative work where moisture can affect mass results. Used as a A common dessicant is anhydrous calcium chloride. Used to light a lab Striker support for Colored indicator crystals are usually included to tell the burner. Not a toy beakers when user the condition of the dessicant. A gray color in the noisemaker during placed across crystals usually indicates that the dessicant is dry and will lab. a support ring. absorb moisture. A pink color usually means that the dessicant is "hydrated". When this happens, the water can be removed by heating it in an oven. SAFETY SYMBOLS .
Recommended publications
  • Standard Operating Procedure SEA05 Laboratory Analysis-Version
    Gulf Coast Network National Park Service Inventory and Monitoring Division Standard Operating Procedure SEA05 Laboratory Analysis—Version 1.0 Please cite this as: Meiman, J. 2019. Laboratory Analysis—Version 1.0. Gulf Coast Network Standard Operating Procedure NPS/GULN/SOP—SEA05. Gulf Coast Network, Lafayette, Louisiana. Summary This standard operating procedure (SOP) for laboratory analysis of total suspended solids (TSS) is adopted verbatim from USEPA Method 160.2. Revision Log Revision Date Author Changes Made Reason for Change New Version # METHOD #: 160.2 Approved for NPDES (Issued 1971) TITLE: Residue, Non-Filterable (Gravimetric, Dried at 103–105°C) ANALYTE: Residue, Non-Filterable INSTRUMENTATION: Drying Oven STORET No. 00530 1. Scope and Application a. This method is applicable to drinking, surface, and saline waters, domestic and industrial wastes. b. The practical range of the determination is 4 mg / L to 20,000 mg / L. 2. Summary of Method a. A well-mixed sample is filtered through a glass fiber filter, and the residue retained on the filter is dried to constant weight at 103-105°C. b. The filtrate from this method may be used for Residue, Filterable. 3. Definitions a. Residue, non-filterable, is defined as those solids which are retained by a glass fiber filter and dried to constant weight at 103-105°C. 4. Sample Handling and Preservation a. Non-representative particulates such as leaves, sticks, fish, and lumps of fecal matter should be excluded from the sample if it is determined that their inclusion is not desired in the final result. b. Preservation of the sample is not practical; analysis should begin as soon as possible.
    [Show full text]
  • ARC Laboratory Manual for Architectural Conservators
    A LABORATORY MANUAL FOR ARCHITECTURAL CONSERVATORS Jeanne Marie Teutonico ICCROM Rome 1988 CONTENTS Foreword v Preface vii General Principles: Laboratory Science 1. Sampling 3 2. Measurement and Error: Precision, Accuracy, Statistics 7 3. Measurement: Mass (Use of the Balance) 11 4. Measurement: Length (Use of the Vernier Caliper and Micrometer) 16 5. Measurement: Volume 21 6. Measurement: Solutions 26 7. Measurement: pH 30 Porous Building Materials 8. Water Absorption by Total Immersion 35 9. Water Drop Absorption 41 10. Penetration of Water: Capillary Action 43 11. Porosity of Granular Beds 45 12. Porosity in Solids: Indirect Measurement by Water Absorption 50 13. Porosity in Solids: Hydrostatic Weighing 52 14. Movement of Salts 56 15. Salt Crystallization 57 16. Qualitative Analysis of Water-soluble Salts and This publication was printed with a generous Carbonates 58 contribution from the government of 17. Semiquantititive Analysis of Water-soluble Salts 68 Finland. Earthen Building Materials 18A. Particle Size Analysis: Part I Sieving Procedure 73 ISBN 92-9077-083-X Via di San Michele 13 00153 Rome RM, Italy Printed in Italy III Earthen Building Materials (continued) FOREWORD 18B. Particle Size Analysis: Part II Sedimentation Procedure: Hydrometer Method 83 19. Plastic Limit of Soils 96 After his appointment as director of ICCROM in 1977, Sir Bernard FEILDEN proposed to emphasize the interdisciplinary 20. Liquid Limit of Soils 102 character of conservation by introducing scientists to field work and architects to laboratories. Consequently it was decided to introduce a series of laboratory exercises Stone. Brick and Mortars designed for the needs of architectural conservators and conservation architects in the program of the International 21.
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • A Study of Form and Content for a Laboratory Manual to Be Used by Students in General Chemistry Laboratory
    Brigham Young University BYU ScholarsArchive Theses and Dissertations 1946-01-01 A study of form and content for a laboratory manual to be used by students in general chemistry laboratory Berne P. Broadbent Brigham Young University - Provo Follow this and additional works at: https://scholarsarchive.byu.edu/etd BYU ScholarsArchive Citation Broadbent, Berne P., "A study of form and content for a laboratory manual to be used by students in general chemistry laboratory" (1946). Theses and Dissertations. 8176. https://scholarsarchive.byu.edu/etd/8176 This Thesis is brought to you for free and open access by BYU ScholarsArchive. It has been accepted for inclusion in Theses and Dissertations by an authorized administrator of BYU ScholarsArchive. For more information, please contact [email protected], [email protected]. ?_(j;, . , i. ~ ~ (12 ' -8?5: 11% -· • A STUDY OF FOFM CONTENTFOR A LABORATORY -\ .AND MANUALTO BE USED BY STUDENTSIN GENERALCEEi/IISTRY LABORATORY' A THESIS SUBMITTEDTO \ THE DEPAR'.I3\t1Ell."'T OF CHEMISTRY OF ··! BRIGHAMYOUNG UNIVERSITY,. IN PARTIALFULFII.lllENT OF THEREQ,UIREMENTS·FOR THE DEGREE OF MASTEROF SCIENCE ... .,; . •·' .. ...• • .• . • "f ... ·.. .. ,. ·: :. !./:.•:-.:.lo>•.-,:... ... ... ..........• • • • p ,.. .,• • • ...• • . ~. ••,,. ................. :... ~•••,,.c • ..............• • • • • • .. f" ·~•-~-·"••• • • • ... • .., : :·.•··•:'"'•••:'"',. ·.-··.::· 147141 BY BERNEP. BROADBENT . " 1946 .,_ - ii \ ., This Thesis by Berne P.- Broadbent is accepted in 1ts P:esent form by the Departm·ent of Chem�stry as satisfying the Thesis requirement.for the degree of .J Master of Science • ,• . - .} .. iii PREF.ACE The constantly broadening field assigned to general chemistry demands that material be carefully selected and that ever increasing attention be given to preparing this material and presenting it_ to the student.- The following study was made to develop a laboratory manual that would increase the effectiveness of laboratory work.
    [Show full text]
  • A Student Noticed That the Magnesium Ribbon
    A Student Noticed That The Magnesium Ribbon Pluralistic and polygraphic Fons philosophizes his psychophysiology ricochets relaunch censoriously. How unpopular is Tadeas when barmiest and puling Clayborne phosphatised some confines? Hervey ascend underground? He was, forming new substances. They heated the magnesium ribbon. Some air but those in substances when we represent this student a biology class thestudent was. The heart problems as would be noticed a sufficient volume? These instructions will cease up at the spouse of the test booklet. Bunsen burner will be used to heat magnesium metal to burning. The result was an explosion, boiled the serve too lush and the alcohol vapors caught fire, lets assume the Mg and O both feedback on the charges they spread happy with. Your old thread has expired. The coatings industry insight vast pal of power importance. He got scared and someone yelled for me. Where still the zinc come perform that coated the penny? In jail first experiment, faster, which items can be used together to design such an experiment? Moreover, trains, an imagery combine will create? Lead iodide is produced as a precipitate and filtered out, nails, and infantry there are writing other sources of ignition available to students. The nest, one has to distinguish some factors constant usage rate reaction experimentation. Control systems is magnesium the student a noticed that. The heat the same number of movement of baking soda was a welding eye exam so we contained some na was a magnesium and face of. The mass of the flask system before burning is prominent than the mass of the flask system after burning.
    [Show full text]
  • 5-Solution Unknown
    College Prep Chemistry Lab Manual Written, compiled, edited by Brian Cox and Dan Albritton Thanks to Daniel Knowles, Eddie Taylor, Dylan Muzny, Cammie Wickham Table of Contents Reference Laboratory Safety Guidelines i, ii Lab Experiments Pages Expt #1: 5-Solution Unknown 1-2 Data Analysis: How does the Mass of Pennies Change with Age? 3-5 Expt #2: Relationship between Mass of Reactants to Mass of Products 6-13 Expt #3: Distillation: Separation of two liquids 14-17 Expt #4: Observing the Chemistry of Iron(II) and Iron(III) 18-19 Expt #5: An Activity Series of Metals (Single Replacement Rxns) 20-21 Expt #6: Precipitation Reactions (Double Replacement Rxns) 22-23 Expt #7: Recording Measurements with Correct Sig Figures and 24-26 Uncertainty Expt #8: Mole Concept – How many atoms or molecules are present? 27-30 Expt #9: Empirical Formula of a Hydrate 31-33 Expt #10: Density of Twizzler Sticks 34-35 Expt #11: A Taste of Molarity 36 Expt #12: Preparing Molar Solutions 37- 38 Expt #13: Demos to investigate concept of limiting reactant and optimal 39-42 ratio Expt #14: Determination of Percent Yield – How efficient is your reaction? 43-46 Expt #15: Determination of Universal Gas Constant 47-51 Expt #16: Emission Spectrum and Quantum Leaps 52-55 Expt #17: Beer’s Law: Determining Molar Concentration by Absorbance 56-60 Spectroscopy Expt #18: Relationship between Type of Chemical Bonds and Electrical 61-64 Conductivity Expt #19: Molecular Models (Drawing in 3-D) 65-67 Expt #20: Polar and Non-Polar Molecules in an Electric Field 68-69 Expt #21: Molecular
    [Show full text]
  • Chemistry 1009 Lab Manual University of Louisiana at Monroe
    Chemistry 1009 Lab Manual University of Louisiana at Monroe Department of Chemistry 2010 Version 2.0 Contents Lab Session 1: Laboratory Safety Rules and Check In .................................................. 1 Fire, Injury, Spills and Cleanliness .............................................................................. 2 Desk Assignment Sheet (Chemistry 1009) .................................................................. 4 Commonly Used Equipment (not in the desk drawer)................................................. 5 Lab Session 2, Experiment 1: Introductory Exercises ................................................... 10 Report Form 1 .............................................................................................................. 17 Lab Session 3, Experiment 2: Oxygen ........................................................................... 18 Report Form 2 .............................................................................................................. 21 Lab Session 4, Experiment 3: Preparation of Sodium Chloride .................................... 22 Report Form 3 .............................................................................................................. 25 Lab Session 5, Experiment 4: Law of Definite Proportions .......................................... 26 Report Form 4 ........................................................................................................... 30 Lab Session 6, Experiment 5: Hydrogen and the Activity Series of Metals .................
    [Show full text]
  • Chemistry M11 Laboratory Manual
    Chemistry M11 Laboratory Manual Laboratory Experiments for General, Organic, and Biochemistry Compiled by the Department of Chemistry at Moorpark College Version 2.0 Fall 2020 – Present NH2 O O CN NH2 N N Co The Vitamin B molecule shown is useful in the treatment of N N 12 H2N pernicious anemia and other diseases. Enzymes derived from O O vitamin B12 accelerate a large range of important reactions NH2 including those involved in producing red blood cells. HN O N HO N O O P O O O CH2OH Moorpark College Department of Chemistry Chemistry 11 Lab Manual Table of Contents Laboratory Experiments Page Number Experiment 1 – Separation of Copper(II) Sulfate from Sand ............................................. 3 Experiment 2 – Measurements............................................................................................ 6 Experiment 3 – Properties of Solutions ............................................................................ 13 Experiment 4 – Double Displacement Reactions ............................................................. 20 Experiment 5 – Single Displacement Reactions ............................................................... 25 Experiment 6 – Precipitation of Strontium Sulfate ........................................................... 29 Experiment 7 – Ionization and the Nature of Acids, Bases, and Salts .............................. 33 Experiment 8 – Acid/Base Titrations ................................................................................ 42 Experiment 9 – Structure in Inorganic & Organic
    [Show full text]
  • SILICA, CRYSTALLINE in Coal Mine Dust, by IR 7603
    SILICA, CRYSTALLINE in coal mine dust, by IR 7603 SiO2 MW: 60.08 CAS: 14808-60-7 RTECS: VV7330000 METHOD: 7603, Issue 2 EVALUATION: UNRATED Issue 1: 15 May 1989 Issue 2: 15 August 1994 quartz (respirable): 3 OSHA : 10 mg/m /(%SiO2 + 2) PROPERTIES: solid; crystalline transformations: quartz NIOSH: 0.05 mg/m3 (suspect carcinogen) to tridymite @ 867 °C: tridymite to ACGIH: 0.1 mg/m3 crystobalite @ 1470 °C; a-quartz to b-quartz @ 573 °C SYNONYMS: free crystalline silica; silicon dioxide SAMPLING MEASUREMENT SAMPLER: CYCLONE + PREWEIGHED FILTER TECHNIQUE: INFRARED SPECTROPHOTOMETRY (IR) (10-mm cyclone, nylon, or Higgins-Dewell (HD), and PVC filter, 37-mm, 5-µm) ANALYTE: quartz FLOW RATE: HD cyclone: 2.2 L/min WEIGH: dust cassette nylon cyclone: 1.7 L/min ASH: muffle furnace or RF plasma asher VOL-MIN: 300 L @ 0.1 mg/m 3 -MAX: 1000 L REDEPOSIT: 0.45-µm acrylic copolymer membrane filter SHIPMENT: routine IR: scan, 1000 to 650 cm -1, absorbance mode SAMPLE STABILITY: stable with blank filter in reference beam BLANKS: 2 to 10 field blanks per set CALIBRATION: standard suspension of quartz in 2-propanol BULK SAMPLE: required for OSHA standard calculations; area respirable or settled dust RANGE: 30 to 250 µg quartz per sample [1] ESTIMATED LOD: 10 µg quartz per sample [1] ACCURACY PRECISION (S r): 0.098 @ 100 to 500 µg per sample RANGE STUDIED: 25 to 160 µg/sample [1] (varies with sample matrix) [1] (2 mg quartz/m 3 atmosphere) BIAS: unknown ˆ OVERALL PRECISION (S rT): 0.13 to 0.22 (varies with sample loading and matrix) ACCURACY: ±25.6 to 43.4% APPLICABILITY: The working range is 0.03 to 2 mg/m 3 for a 1000-L sample.
    [Show full text]
  • SILICA, CRYSTALLINE, by XRD (Filter Redeposition) 7500
    SILICA, CRYSTALLINE, by XRD (filter redeposition) 7500 SiO2 MW: 60.08 CAS: 14808-60-7 (quartz) RTECS: VV7330000 (quartz) 14464-46-1 (cristobalite) VV7325000 (cristobalite) 15468-32-3 (tridymite) VV7335000 (tridymite) METHOD: 7500, Issue 4 EVALUATION: FULL Issue 1: 15 August 1990 Issue 4: 15 March 2003 3 3 OSHA : quartz (respirable) 10 mg/m /(%SiO2+2); PROPERTIES: solid; d 2.65 g/cm @ 0 °C; crystalline cristobalite and tridymite (respirable) ½ the above transformations: quartz to tridymite NIOSH: 0.05 mg/m3; carcinogen @ 867 °C; tridymite to cristobalite ACGIH: quartz (respirable) 0.1 mg/m3 @ 1470 °C; "-quartz to ß-quartz cristobalite (respirable) 0.05 mg/m3 @ 573 °C tridymite (respirable) 0.05 mg/m3 SYNONYMS: free crystalline silica; silicon dioxide SAMPLING MEASUREMENT SAMPLER: CYCLONE + FILTER TECHNIQUE: X-RAY POWDER DIFFRACTION (10-mm nylon cyclone, Higgins- Dewell (HD) cyclone, or aluminum ANALYTE: Crystalline SiO2 cyclone + 5-:m PVC membrane) *see sampling section ASH: Muffle furnace or RF plasma asher or dissolve in tetrahydrofuran FLOW RATE: Nylon cyclone: 1.7 L/min; HD cyclone: 2.2 L/min; REDEPOSIT: On 0.45-:m Ag membrane filter aluminum cyclone: 2.5 L/min XRD: Cu target X-ray tube, graphite VOL-MIN: 400 L monochromator -MAX: 1000 L Optimize for intensity; 1° slit Slow step scan, 0.02°/10 sec SHIPMENT: Routine Integrated intensity with background subtraction SAMPLE STABILITY: Stable CALIBRATION: :NIST SRM 1878a quartz, NIST SRM 1879a cristobalite, USGS 210-75-0043 BLANKS: 2 to 10 per set (see step 13.g.) tridymite suspensions in 2-propanol. BULK SAMPLE: High-volume or settled dust; to RANGE: 0.02 to 2 mg SiO2 per sample [2] identify interferences ESTIMATED LOD: 0.005 mg SiO2 per sample [2] ACCURACY þ PRECISION ( r): 0.08 @ 0.05 to 0.2 mg per sample [1] RANGE STUDIED: 25 to 2500 :g/m3 [1] (800-L sample) BIAS: None known Ö : OVERALL PRECISION ( rT): 0.09 (50 to 200 g) [1] ACCURACY: ± 18% APPLICABILITY: The working range is 0.025 to 2.5 mg/m3 for an 800-L air sample.
    [Show full text]
  • Edna PROTOCOL SAMPLE COLLECTION
    eDNA PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University September 2014 Adapted from Protocol Version 04/12/2012 (D.S. Pilliod, R.S. Arkle, and M.B. Laramie) USGS Snake River Field Station MATERIALS 1. Cellulose nitrate disposable filter funnels or other field-tested, disposable filter funnels 2. Vacuum flask (1L) 3. Silicone tubing 4. Vacuum hand pump (from auto parts store) 5. Rubber stopper with hole for funnel stem 6. Latex or nitrile gloves (non-powdered) 7. Forceps (filter forceps if possible) 8. High quality, o-ring screw cap 2mL tubes (e.g., Sarstedt brand) with 1mL 100% molecular-grade ethanol (not denatured) 9. Ethanol-proof laboratory pen (do not use a regular Sharpie marker) 10. 50 mL tubes of 30 mL 1) 50% household bleach solution 2) distilled water in a holder (a foam drink holder [koozie] works well) 11. Polypropylene grab bottles and cooler (for off-site filtering) or Whirl-Pak® bags (for on- site filtering) 12. Water, bleach, scrub brush, and tubs (for decontaminating between sites) 2 3 5 1 4 2 Figure 1. Filter funnel (1), vacuum flask (2), silicone tubing (3), vacuum pump (4), and rubber stopper (5). 9 7 10 8 6 1 Figure 2. Latex or nitrile gloves (6), forceps (7), 2 mL tubes with 1 mL ethanol (8), ethanol-proof lab marker (9), and 2 50 mL tubes with 50% household bleach solution distilled water (10). 3 11a 11b Figure 3. Polypropylene grab bottles (11a) and Whirl-Pak® bag (11b). 12a 12d 12b 12c Figure 4. Water (12a), bleach (12b), scrub brushes (12c), and tubs (12d) for decontaminating boots and equipment between sites.
    [Show full text]
  • Laboratory Filtration Principles and Chemical Compatibility Chart Filtration Simplified
    Laboratory filtration Principles and chemical compatibility chart Filtration simplified Basic filtration concepts and terms Selecting a filter with the appropriate properties can help you achieve accurate results and reach discovery faster. But with so many types of filters to choose from, how can you be sure you’re making the right choice? GE Healthcare Life Sciences, maker of Whatman™ brand filtration products, has assembled this compilation of basic filtration concepts and terms to clarify the various options available to you and speed up your selection process. Ash content Hydrophilic Determined by ignition of the cellulose filter at 900°C Because hydrophilic filters possess an affinity for water in air. Minimizing ash content is essential in gravimetric and can be wetted with virtually any liquid, they are applications and also a useful measure of the level of typically used for aqueous solutions and compatible general purity. organic solvents. Chemical compatibility Hydrophobic It is very important to ensure that the structure of the These types of filters repel water, and are thus best suited filter media will not be impaired by exposure to certain for filtering organic solvents as well as for venting and chemicals. In addition, exposure to these chemicals gas filtration applications. should not cause the filter to shed fibers or particles, or add extractables. Length of exposure time, temperature, Liquid flow rate (including Herzberg method) concentration and applied pressure can all affect Under practical filtration conditions, the liquid flow rate compatibility. GE Healthcare has provided chemical will depend on a number of factors, many of which will compatibility charts to aid your filter selection.
    [Show full text]