RAJASTHAN RAJYA VIDYUT PRASARAN NIGAM LTD. [Corporate Identity Number (CIN):U40109RJ2000SGC016485] Regd
Total Page:16
File Type:pdf, Size:1020Kb
RAJASTHAN RAJYA VIDYUT PRASARAN NIGAM LTD. [Corporate Identity Number (CIN):U40109RJ2000SGC016485] Regd. Office: Vidyut Bhawan, Jyoti Nagar, Jaipur-302005 OFFICE OF THE ASSISTANT ENGINEER (T&C) 132 KV GSS CAMPUS, MANI VIHAR, JHUNJHUNU Tel. No. 01592-230120, Mob.-9414061317 E-mail:[email protected], Website: www.rvpn.co.in No.- RVPN/AEN/T&C/JJN/ ESTT./ F. NIT /D- 87 Date: 07.07.2017 NOTICE FOR INVITING TENDER FOR FILTRATION OF TRANSFORMER OIL OF 132/33 KV 40/50 MVA POWER TRANSFORMER AT 132 KV GSS GUDHA GORJI Limited Nib No.-04/2017-18 Sealed tender are invited from reputed firms for filtration of transformer oil of 132/33 KV, 40/50 MVA power transformer at 132 KV GSS GudhaGorji. Tenders should be accepted by the office of the Assistant Engineer (T&C) RVPN Jhunjhunu up to 2.30 PM dated 14.07.2017and will be open on same date at 3.00 PM in the presence of bidders or there representative who may be present. S. No. Particulars of Items Qty. to be executed 1. FILTERATION OF TRANSFORMER OIL OF 132/33KV, 40/50 As per G-Schedule MVA POWER TRANSFORMER AT 132KV GSS, GUDHAGORJI attached Subject to the following terms and conditions:- 1. The rate prices should be quoted by the firm as per G-Schedule. 2. The contractor will have arrange Filtration of about 17.50 KL of transformer oil at our site of 132KV GSS, GUDHAGORJI by providing high vacuum Filtration machine and oil testing kit, having 100KV capacity. 3. Filtration of oil in Transformer Tank or in separate tank as the case may be and Filling in the transformer up to mark level in conservator. 4. Circulation of oil through filter plant in transformer till they require BDV and PPM achieved i.e. BDV above 80KV and PPM less than 10 or as per latest IEC. 5. After all above process the oil shall be top up, up to mark level in Conservator. 6. For carrying out about said work, the contractor will have to arrange his own Filtration Machine. 7. After receiving W.O. the contractor shall have to depute his working team with Filtration Machine and T&P within 7 Days. 8. Required electricity for above said work shall be provided by the RRVPNL, free of cost to the Contractor. 9. Oil tank, required of suitable capacity would be provided by the RRVPNL, at site. 10. The contractor will be fully responsible in case of occurrence of any accident Fatal/Non- Fatal, caused by his equipment under the contract, causing death or serious injury permanent/ partial disability to the employees. The contractor will keep the RRVPNL, indemnified from any such liability. Assistant Engineer (T&C) RVPNL, Jhunjhunu Copy submitted/forwarded to the following: 1. The Superintending Engineer (T&C) RVPN, Babai. 2. The Executive Engineer (T&C) RVPN, Babai. 3. The Account Officer (T&C) RVPN, Babai. 4. The Feeder Manager (T&C) RVPN Sikar to upload on RVPN website. Assistant Engineer (T&C) RVPNL, Jhunjhunu RAJASTHAN RAJYA VIDYUT PRASARAN NIGAM LTD. [Corporate Identity Number (CIN):U40109RJ2000SGC016485] Regd. Office: Vidyut Bhawan, Jyoti Nagar, Jaipur-302005 OFFICE OF THE ASSISTANT ENGINEER (T&C) 132 KV GSS CAMPUS, MANI VIHAR, JHUNJHUNU Tel. No. 01592-230120, Mob.-9414061317 E-mail:[email protected], Website: www.rvpn.co.in G-SCHEDULE FOR FILTRATION WORK OF TRANSFORMER OIL OF 132/33 KV, 40/50 MVA, TECHNICAL ASSOCIATES MAKE POWER TRANSFORMER AT 132 KV GSS GUDHAGORJI DISTT.- JHUNJHUNU (RAJ.) Name of Work: FILTRATION WORK OF TRANSFORMER OIL OF 132/33 KV, 40/50 MVA, TECHNICAL ASSOCIATES MAKE POWER TRANSFORMER AT 132 KV GSS GUDHAGORJI DISTT. JHUNJHUNU(RAJ.) Name of Office: AEN (T&C), RVPNL, Jhunjhunu Location of Oil Filtration: 132 KV GSS, RVPNL, GUDHAGORJI Code Description of work Unit Quantity Rate/Unit Amount No. 30.7 Dehydration/Filtration and reconditioning of Litre 17500 Transformer Oil of 132/33 KV, 40/50 MVA Power Transformer at 132 KV GSS, Gudhagorji (by providing high vacuum Filtration machine and oil testing kit, having 100 KV capacity), as per norms and testing thereof in presence of sub-station works in charge. (Electricity shall be supplied by deptt.) Total Rs. Total Rs (In Words):-…………………………………………………………………………………………………………. Assistant Engineer (T&C) RVPNL Jhunjhunu 1. I/We have read terms and conditions of the Tender Enquiry. These are acceptable to us. 2. Our Offer is valid for 90 days from the date of opening of tenders. 3. The work shall be completed within stipulated period and as per instructions of the Engineer in Charge. 4. The quoted rate is firm in all respect till completion of work including all taxes and duties as applicable from time to time. 5. We shall arrange all “Tools and Plants” for execution of work at our cost. 6. Safe execution of work shall be our responsibility. 7. We shall be responsible for any “Fatal” or Non- Fatal” accident taking place due to our negligence. 8. Any damage(s) to Nigam’s property in vicinity shall be our responsibility. Signature of Contractor: ………………………… Address: …………………………………… Name of Contractor: ………………………………. ………………………………….. Date Seal & Signature Assistant Engineer (T&C) RVPNL, Jhunjhunu .