Safety Data Sheet

Total Page:16

File Type:pdf, Size:1020Kb

Safety Data Sheet SAFETY DATA SHEET Creation Date 18-Apr-2011 Revision Date 19-Mar-2018 Revision Number 1 SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING 1.1. Product identification Product Description: Misch metal Cat No. : 45589 Synonyms Misch metal cerium CAS-No 62379-61-7 Molecular Formula Ce Reach Registration Number - 1.2. Relevant identified uses of the substance or mixture and uses advised against Recommended Use Laboratory chemicals. Uses advised against No Information available 1.3. Details of the supplier of the safety data sheet Company Alfa Aesar . Avocado Research Chemicals, Ltd. Shore Road Port of Heysham Industrial Park Heysham, Lancashire LA3 2XY United Kingdom Office Tel: +44 (0) 1524 850506 Office Fax: +44 (0) 1524 850608 E-mail address [email protected] www.alfa.com Product Safety Department 1.4. Emergency telephone number Call Carechem 24 at +44 (0) 1865 407333 (English only); +44 (0) 1235 239670 (Multi-language) SECTION 2: HAZARDS IDENTIFICATION 2.1. Classification of the substance or mixture CLP Classification - Regulation (EC) No 1272/2008 Physical hazards Flammable solids Category 2 (H228) Substances/mixtures which, in contact with water, emit flammable gases Category 3 (H261) Health hazards Based on available data, the classification criteria are not met Environmental hazards Based on available data, the classification criteria are not met ______________________________________________________________________________________________ ALFAA45589 Page 1 / 9 SAFETY DATA SHEET Misch metal Revision Date 19-Mar-2018 ______________________________________________________________________________________________ 2.2. Label elements Signal Word Warning Hazard Statements H228 - Flammable solid H261 - In contact with water releases flammable gases May form combustible dust concentrations in air Precautionary Statements P231 + P232 - Handle under inert gas. Protect from moisture P210 - Keep away from heat/sparks/open flames/hot surfaces. - No smoking 2.3. Other hazards No information available SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Component CAS-No EC-No. Weight % CLP Classification - Regulation (EC) No 1272/2008 Misch metal, cerium 62379-61-7 >95 Flam. Sol. 2 (H228) Water react. 3 (H261) Cerium 7440-45-1 EEC No. 231-154-9 47-60 Flam. Sol. 2 (H228) Lanthanum 7439-91-0 EEC No. 231-099-0 20-38 - Neodymium 7440-00-8 EEC No. 231-109-3 1-20 - Praseodymium 7440-10-0 EEC No. 231-120-3 5-10 Flam. Sol. 2 (H228) Reach Registration Number - Full text of Hazard Statements: see section 16 SECTION 4: FIRST AID MEASURES 4.1. Description of first aid measures Eye Contact Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention. Skin Contact Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. Obtain medical attention. Ingestion Clean mouth with water. Get medical attention. Inhalation Remove from exposure, lie down. Move to fresh air. ______________________________________________________________________________________________ ALFAA45589 Page 2 / 9 SAFETY DATA SHEET Misch metal Revision Date 19-Mar-2018 ______________________________________________________________________________________________ Self-Protection of the First Aider Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and prevent spread of contamination. 4.2. Most important symptoms and effects, both acute and delayed No information available. 4.3. Indication of any immediate medical attention and special treatment needed Notes to Physician Treat symptomatically. SECTION 5: FIREFIGHTING MEASURES 5.1. Extinguishing media Suitable Extinguishing Media Dry chemical. approved class D extinguishers. clay. dry ground dolomite. sodium carbonate. Extinguishing media which must not be used for safety reasons Water. Do not use halon type extinguisher. Carbon dioxide (CO 2). 5.2. Special hazards arising from the substance or mixture Combustible material. Fine dust dispersed in air may ignite. Hazardous Combustion Products Silicon dioxide, Hydrogen. 5.3. Advice for firefighters As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. SECTION 6: ACCIDENTAL RELEASE MEASURES 6.1. Personal precautions, protective equipment and emergency procedures Ensure adequate ventilation. 6.2. Environmental precautions See Section 12 for additional ecological information. 6.3. Methods and material for containment and cleaning up Avoid dust formation. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Sweep up or vacuum up spillage and collect in suitable container for disposal. Do not expose spill to water. 6.4. Reference to other sections Refer to protective measures listed in Sections 8 and 13. SECTION 7: HANDLING AND STORAGE ______________________________________________________________________________________________ ALFAA45589 Page 3 / 9 SAFETY DATA SHEET Misch metal Revision Date 19-Mar-2018 ______________________________________________________________________________________________ 7.1. Precautions for safe handling Avoid contact with skin and eyes. Do not breathe dust. Use explosion-proof equipment. Use only non-sparking tools. Minimize dust generation and accumulation. Do not allow contact with water. Hygiene Measures Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing before re-use. Wash hands before breaks and at the end of workday. 7.2. Conditions for safe storage, including any incompatibilities Keep in a dry, cool and well-ventilated place. Keep container tightly closed. Keep away from heat and sources of ignition. Protect from moisture. Flammables area. 7.3. Specific end use(s) Use in laboratories SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 8.1. Control parameters Exposure limits This product, as supplied, does not contain any hazardous materials with occupational exposure limits established by the region specific regulatory bodies Biological limit values This product, as supplied, does not contain any hazardous materials with biological limits established by the region specific regulatory bodies Monitoring methods BS EN 14042:2003 Title Identifier: Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents. MDHS14/3 General methods for sampling and gravimetric analysis of respirable and inhalable dust Derived No Effect Level (DNEL) No information available Route of exposure Acute effects (local) Acute effects Chronic effects Chronic effects (systemic) (local) (systemic) Oral Dermal Inhalation Predicted No Effect Concentration No information available. (PNEC) 8.2. Exposure controls Engineering Measures Use explosion-proof electrical/ventilating/lighting/equipment. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source Personal protective equipment ______________________________________________________________________________________________ ALFAA45589 Page 4 / 9 SAFETY DATA SHEET Misch metal Revision Date 19-Mar-2018 ______________________________________________________________________________________________ Eye Protection Goggles (European standard - EN 166) Hand Protection Protective gloves Glove material Breakthrough time Glove thickness EU standard Glove comments Natural rubber See manufacturers - EN 374 (minimum requirement) Nitrile rubber recommendations Neoprene PVC Skin and body protection Wear appropriate protective gloves and clothing to prevent skin exposure Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination. Respiratory Protection When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly Large scale/emergency use Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Particulates filter conforming to EN 143 Small scale/Laboratory use Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001 When RPE is used a face piece Fit Test should be conducted Environmental exposure controls No information available. SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 9.1. Information on basic physical and chemical properties Appearance Grey Physical State Solid Odor Odorless Odor Threshold
Recommended publications
  • Safety Data Sheet
    Coghlan’s Magnesium Fire Starter #7870 SAFETY DATA SHEET This Safety Data Sheet complies with the Canadian Hazardous Product Regulations, the United States Occupational Safety and Health Administration (OSHA) Hazard Communication Standard, 29 CFR 1910 (OSHA HCS), and the European Union Directives. 1. Product and Supplier Identification 1.1 Product: Magnesium Fire Starter 1.2 Other Means of Identification: Coghlan’s #7870 1.3 Product Use: Fire starter 1.4 Restrictions on Use: None known 1.5 Producer: Coghlan’s Ltd., 121 Irene Street, Winnipeg, Manitoba Canada, R3T 4C7 Telephone: +1(204) 284-9550 Facsimile: +1(204) 475-4127 Email: [email protected] Supplier: As above 1.6 Emergencies: +1(877) 264-4526 2. Hazards Identification 2.1 Classification of product or mixture This product is an untested preparation. GHS classification for this preparation is based upon its use as a fire starter by making shavings and small particulate from the metal block. As shipped in mass form, this preparation is not considered to be a hazardous product and is not classifiable under the requirements of GHS. GHS Classification: Flammable Solids, Category 1 2.2 GHS Label Elements, including precautionary statements Pictogram: Signal Word: Danger Page 1 of 11 October 18, 2016 Coghlan’s Magnesium Fire Starter #7870 GHS Hazard Statements: H228: Flammable Solid GHS Precautionary Statements: Prevention: P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P280: Wear protective gloves, eye and face protection Response: P370+P378: In case of fire use water as first choice. Sand, earth, dry chemical, foam or CO2 may be used to extinguish.
    [Show full text]
  • Hot Surface Ignition Temperature of Dust Layers with and Without Combustible Additives
    HOT SURFACE IGNITION TEMPERATURE OF DUST LAYERS WITH AND WITHOUT COMBUSTIBLE ADDITIVES by Haejun Park A Thesis Submitted to the Faculty of the WORCESTER POLYTECHNIC INSTITUTE in partial fulfillment of the requirements for the Degree of Master of Science in Fire Protection Engineering May 2006 APPROVED: Professor Robert G. Zalosh, Advisor Joseph A. Senecal, Kiddie-Fenwal, Inc., Co-advisor Professor Kathy A. Notarianni, Head of Department Abstract An accumulated combustible dust layer on some hot process equipment such as dryers or hot bearings can be ignited and result in fires when the hot surface temperature is sufficiently high. The ASTM E 2021 test procedure is often used to determine the Hot Surface Minimum Ignition Temperature for a half inch deep layer of a particular dust material. This test procedure was used in this thesis to study possible effects of combustible liquid (such as lubricating oil) and powder additives in the dust layer as well as air flow effects. The following combustible dusts were used: paper dust from a printing press, Arabic gum powder, Pittsburgh seam coal, and brass powder. To develop an improved understanding of the heat transfer, and oxygen mass transfer phenomena occurring in the dust layer, additional instrumentation such as a second thermocouple in the dust layer, an oxygen analyzer and gas sampling line, and an air velocity probe were used in at least some tests. Hot Surface Minimum Ignition temperatures were 220oC for Pittsburgh seam coal, 360oC for paper dust, 270℃ for Arabic gum powder, and > 400oC for brass powder. The addition of 5-10 weight percent stearic acid powder resulted in significantly lower ignition temperature of brass powder.
    [Show full text]
  • Fire Hazard Analysis Techniques Chapter Contents Performing a Fire Morgan J
    SECTION 3 Chapter 7 Fire Hazard Analysis Techniques Chapter Contents Performing a Fire Morgan J. Hurley Richard W. Bukowski Hazard Analysis Developing Fire Scenarios and Design Fire Scenarios vailable methods to estimate the potential impact of fire can be divided into two categories: Quantification of Design risk-based and hazard-based. Both types of methods estimate the potential consequences of Fire Scenarios A Prediction of Hazards possible events. Risk-based methods also analyze the likelihood of scenarios occurring, whereas hazard-based methods do not. Fire risk analysis is described more fully in Section 3, Chapter 8, “Fire Risk Analysis.” Section 3, Chapter 9, “Closed Form Enclosure Fire Calculations,” provides Key Terms simple fire growth calculation methods. bounding condition, design The goal of a fire hazards analysis (FHA) is to determine the expected outcome of a specific fire curve, design fire set of conditions called a fire scenario. The scenario includes details of the room dimensions, con- scenario, fire hazard tents, and materials of construction; arrangement of rooms in the building; sources of combustion analysis, fire model, fire air; position of doors; numbers, locations, and characteristics of occupants; and any other details scenario, performance- that have an effect on the outcome of interest. This outcome determination can be made by expert based design, t-squared fire judgment, by probabilistic methods using data from past incidents, or by deterministic means such as fire models. “Fire models” include empirical correlations, computer programs, full-scale and reduced-scale models, and other physical models. The trend today is to use models whenever pos- sible, supplemented if necessary by expert judgment.
    [Show full text]
  • SAFETY STANDARD for HYDROGEN and HYDROGEN SYSTEMS Guidelines for Hydrogen System Design, Materials Selection, Operations, Storage, and Transportation
    NSS 1740.16 National Aeronautics and Space Administration SAFETY STANDARD FOR HYDROGEN AND HYDROGEN SYSTEMS Guidelines for Hydrogen System Design, Materials Selection, Operations, Storage, and Transportation Office of Safety and Mission Assurance Washington, DC 20546 PREFACE This safety standard establishes a uniform Agency process for hydrogen system design, materials selection, operation, storage, and transportation. This standard contains minimum guidelines applicable to NASA Headquarters and all NASA Field Centers. Centers are encouraged to assess their individual programs and develop additional requirements as needed. “Shalls” and “musts” denote requirements mandated in other documents and in widespread use in the aerospace industry. This standard is issued in loose-leaf form and will be revised by change pages. Comments and questions concerning the contents of this publication should be referred to the National Aeronautics and Space Administration Headquarters, Director, Safety and Risk Management Division, Office of the Associate for Safety and Mission Assurance, Washington, DC 20546. Frederick D. Gregory Effective Date: Feb.12, 1997 Associate Administrator for Safety and Mission Assurance i ACKNOWLEDGMENTS The NASA Hydrogen Safety Handbook originally was prepared by Paul M. Ordin, Consulting Engineer, with the support of the Planning Research Corporation. The support of the NASA Hydrogen-Oxygen Safety Standards Review Committee in providing technical monitoring of the standard is acknowledged. The committee included the following members: William J. Brown (Chairman) NASA Lewis Research Center Cleveland, OH Harold Beeson NASA Johnson Space Center White Sands Test Facility Las Cruces, NM Mike Pedley NASA Johnson Space Center Houston, TX Dennis Griffin NASA Marshall Space Flight Center Alabama Coleman J. Bryan NASA Kennedy Space Center Florida Wayne A.
    [Show full text]
  • FIREDOC Vocabulary List, 3Rd Edition
    FIREDOC Vocabulary List, 3rd Edition II^STT United states Department of Commerce XI I National Institute of Standards and Technology NATIONAL INSTITUTE OF STANDARDS & TECHNOLOGY Research Information Center Gaithersburg, MD 20899 DATE DUE Demco, inc. 38-293 NIST Special Publication 779 FIREDOC Vocabulary List, 3rd Edition Nora H. Jason Center for Fire Research National Engineering Laboratory National Institute of Standards and Technology Gaithersburg, MD 20899 (Supersedes NBSIR 85-3231 and NBSIR 87-3545) February 1990 U.S. Department of Commerce Robert A. Mosbacher, Secretary National Institute of Standards and Technology John W. Lyons, Director National Institute of Standards U.S. Government Printing Office For sale by the Superintendent and Technology Washington: 1990 of Documents Special Publication 779 U.S. Government Printing Office (Supersedes NBSIR 85-3231 Washington, DC 20402 and NBSIR 87-3545) Natl. Inst. Stand. Technol. Spec. Publ. 779 104 pages (Feb. 1990) CODEN: NSPUE2 Contents Acknowledgments v Introduction 1 Symbol Notation 1 Terms Beginning with A 3 Terms Beginning with B 11 Terms Beginning with C 15 Terms Beginning with D 23 Terms Beginning with E 29 Terms Beginning with F 33 Terms Beginning with G 43 Terms Beginning with H 45 Terms Beginning with I 51 Terms Beginning with J 55 Terms Beginning with K 57 Terms Beginning with L 59 Terms Beginning with M 63 Terms Beginning with N 69 Terms Beginning with O 71 Terms Beginning with P 73 Terms Beginning with Q 81 Terms Beginning with R 83 Terms Beginning with S 87 iii Terms Beginning with T 95 Terms Beginning with U 101 Terms Beginning with V 103 Terms Beginning with W 105 Terms Beginning with X 107 Terms Beginning with Y 109 Terms Beginning with Z Ill iv Acknowledgments Richard D.
    [Show full text]
  • Autoignition Temperature Determinations and Their Relationship to Other Types of Potential Ignition Sources and Their Applicatio
    I. CHEM. E. SYMPOSIUM SERIES NO. 58 AUTOIGNITION TEMPERATURE DETERMINATIONS & THEIR RELATIONSHIP TO OTHER TYPES OF POTENTIAL IGNITION SOURCES & THEIR APPLICATION TO PRACTICAL SITUATIONS D J Lewis Developments in the measurement of autoignition temperature values are reviewed and the differences between various methods noted. For certain applications, the volume of mixture which can potentially ignite is considerably different to that used in laboratory determinations and the effect of volume on autoignition temperature is analysed. A method of extrapolation which links in to data relating to flame kernal establishment by other ignition sources is outlined and the application of autoignition temperature values to practical situations is discussed in detail. INTRODUCTION Standard test methods for the determination of autoignition temperatures of vaporised liquids and gases in air at atmospheric pressure have been available in various forms since 1930. A considerable number of values for different fuels (both as pure materials and mixtures) have been published and have found specific application as regards the selection of electrical equipment for hazardous locations. Recently there have been developments relating to new methods for determining a reaction threshold temperature for liquid and solid materials in air and also regarding the distinction between the temperatures at which cool flame behaviour will be produced and at which normal combustion type flames result. The combination of economic pressures and higher standards of chemical processing safety is leading to the increasing use of autoignition temperature values under conditions widely different from those used to determine them. As a result it is appropriate to review the autoignition temperature test methods and techniques for the application of such values to practical situations.
    [Show full text]
  • Fire Investigation of Spontaneous Heating
    Fire Investigation of Spontaneous Heating Author: Donald E Berg, Senior Principal Consultant, Envista Forensics The investigation of spontaneous heating fires can be challenging and come with a unique set of circumstances due to many factors; evidence Highlights is consumed, a site is left with little or no evidentiary material, or collected evidence sent for laboratory analysis does not show the presence of • Self-Heating Spontaneous chemical residues. Additionally, burn patterns from such fires can be Combustion difficult to interpret. • Autoignition of Fires The methodology for performing an origin and cause investigation after • Investigation of Spontaneous a spontaneous heating fire does not change, but the efforts to determine Ignition the specific area of origin needs to be well established before spontaneous • Case Study and Myths ignition can be confirmed. This type of investigation requires in-depth analyses of the events leading up to the fire including witness statements, a precise timeline, weather conditions (including the temperature and humidity), and the location of any contributing factors, such as material remains or product residue. Spontaneous Combustion Due to Self-Heating The 2021 edition of the National Fire Protection Association (NFPA), chapter 5, section 5.7.4.1.1.5, describes spontaneous combustion due to self-heating as a special form of smoldering ignition that does not involve an external heating process. This happens when an exothermic reaction within the material leads to ignition and burning. According to the NFPA, when a material is able to dissipate the heat generated by internal exothermic reactions, it is considered ignition by self-heating. If the generated heat cannot be dissipated to the surroundings, the material will rise in temperature and a smolder front can be formed.
    [Show full text]
  • Summary of Assessment of the Safety, Health, Environmental and System Risks of Alternative Fuels
    U.S. Department of Transportation Federal Transit Agency FTA-MA-90-7007-95-1 DOT-VNTSC-FTA-95-5 CLEAN AIR PROGRAM SUMMARY OF ASSESSMENT OF THE SAFETY, HEALTH, ENVIRONMENTAL AND SYSTEM RISKS OF ALTERNATIVE FUELS U.S. Department of Transportation Research and Special Programs Administration John A. Volpe National Transportation Systems Center Cambridge, MA 02142 Federal Transit Administration August 1995 Final Report PDF Edition April 1999 NOTICE This document is disseminated under the sponsorship of the Department of Transportation in the interest of information exchange. The United States Government assumes no liability for its contents or use thereof. NOTICE The United States Government does not endorse products or manufacturers. Trade or manufacturers' names appear herein solely because they are considered essential to the objective of this report. Form Approved REPORT DOCUMENTATION PAGE OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project (0704-0188), Washington, DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE 3. REPORT TYPE AND DATES COVERED August 1995 Final Report – March 1995 4. TITLE AND SUBTITLE 5.
    [Show full text]
  • Autoignition of R32 and R410 Refrigerant Mixtures With
    Purdue University Purdue e-Pubs International Refrigeration and Air Conditioning School of Mechanical Engineering Conference 2014 Autoignition of R32 and R410 Refrigerant Mixtures with Lubricating Oil Adam Boussouf Department of Fire Protection Engineering, University of Maryland, College Park MD USA, [email protected] Vivien R. Lecoustre Department of Fire Protection Engineering, University of Maryland, College Park MD USA, [email protected] Hao Li Goodman Manufacturing, Houston TX USA, [email protected] Robert By Goodman Manufacturing, Houston TX USA, [email protected] Peter B. Sunderland Department of Fire Protection Engineering, University of Maryland, College Park MD USA, [email protected] Follow this and additional works at: http://docs.lib.purdue.edu/iracc Boussouf, Adam; Lecoustre, Vivien R.; Li, Hao; By, Robert; and Sunderland, Peter B., "Autoignition of R32 and R410 Refrigerant Mixtures with Lubricating Oil" (2014). International Refrigeration and Air Conditioning Conference. Paper 1555. http://docs.lib.purdue.edu/iracc/1555 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html 2672, Page 1 Ignition of R-32 and R-410A Refrigerant Mixtures with Lubricating Oil Adam BOUSSOUF1, Vivien R. LECOUSTRE2, Hao LI3, Robert BY4, Peter B. SUNDERLAND5,*
    [Show full text]
  • Second Revision No. 1-NFPA 53-2015 [ Section No
    National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... Second Revision No. 1-NFPA 53-2015 [ Section No. F.3.3.8 ] 1 of 16 6/5/2015 2:42 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... F.3.3.8 2 of 16 6/5/2015 2:42 PM National Fire Protection Association Report http://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPara... The oxygen index test, ASTM D2863, and variations of it have come into wide use in the last few years for their characterizations of the flammability of materials. In the ASTM procedure, a small, vertically oriented sample is burned downward in a candle-like fashion in an oxygen-nitrogen mixture. The composition of the gas mixture is adjusted to determine the minimum percent of oxygen that will begin to support combustion of the sample. This minimum oxygen concentration is called the oxygen index (OI). Burning in an upward direction can take place more readily and produce a lower OI. The OI test, as determined by ASTM D2863, is limited to nonmetals (e.g., plastics) at ambient pressure. However, the OI concept is now utilized at elevated pressures (and temperatures) and for metals as well as nonmetals (see F.3.4 for the OI data of metals) . Other means of ignition have also been used, as have other oxidants and diluents. (44, 45) Conceptually, an OI is a flammability limit but is more complex than the flammability limit for gas mixtures. Therefore, the OI is only one of several criteria that can be utilized to evaluate the suitability of materials for a specific oxygen application.
    [Show full text]
  • Risk Focus Engine Room Fires
    RISK FOCUS: ENGINE ROOM FIRES The majority of onboard fires originate in the engine room CONTENTS Reducing the risk of fire in the engine room 1 Fire essentials 1 Ignition processes 1 Oil fires 2 Hot surface ignition and preventative measures 2 Lagging fires 4 Tank save-alls 4 Solid fuels 5 Gaseous fuels 6 Electrical fires 6 Scavenge fires 8 Soot fires in exhaust gas boilers/economisers 8 Boilers and incinerators 8 Visual inspections 9 Fire safety systems 9 Fire detection 9 Fire suppression 9 Fixed fire suppression systems 10 Limiting fire spread 11 Escape routes and escape doors 12 Emergency shut-down equipment 13 Quick Closing Valves 13 Summary 14 Appendix 1 15 Glossary of terms 16 Reducing the risk of fire in the engine room Considering the wide range of both sources of fuel and sources of ignition within the engine room, it should come as little surprise that a large proportion of fires onboard ships originate there. Research coordinated by IMO1 has indicated that between conducting fire risk assessments and implementing fire 30 and 50% of all fires on merchant ships originate in the prevention measures. engine room and 70% of those fires are caused by oil leaks from pressurised systems. Following a major engine room fire In an engine room there is inevitably a plentiful supply of air it is relatively rare that a ship is able to proceed under her and very effective ventilation systems. It is helpful, however, own power. This leads to expensive costs of salvage, towage, to consider in a little more detail the other two elements of repairs, downtime, cancellation of cruises, etc, which can the fire triangle; ‘sources of ignition’ and ‘fuels’.
    [Show full text]
  • Prediction of Auto-Ignition Temperatures and Delays for Gas Turbine Applications
    Prediction of auto-ignition temperatures and delays for gas turbine applications Roda Bounaceur, Pierre-Alexandre Glaude, Baptiste Sirjean, René Fournet, Pierre Montagne, Matthieu Vierling, Michel Moliere To cite this version: Roda Bounaceur, Pierre-Alexandre Glaude, Baptiste Sirjean, René Fournet, Pierre Montagne, et al.. Prediction of auto-ignition temperatures and delays for gas turbine applications. Journal of Engineer- ing for Gas Turbines and Power, American Society of Mechanical Engineers, 2016, 138, pp.021505. 10.1115/1.4031264. hal-01241520 HAL Id: hal-01241520 https://hal.archives-ouvertes.fr/hal-01241520 Submitted on 10 Dec 2015 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. GTP-15-1341 Prediction of auto-ignition temperatures and delays for gas turbine applications Roda Bounaceur, Pierre-Alexandre Glaude, Baptiste Sirjean, René Fournet, LRGP CNRS, Université de Lorraine 1, rue Grandville - BP 20451 - 54001 Nancy, France Pierre Montagne, Matthieu Vierling, GE Energy Product-Europe, 20 avenue de Maréchal Juin, BP 379, 90007 Belfort, France Michel Molière IRTES-LERMPS – Université de Technologie de Belfort Montbéliard 90010 Belfort Cedex, France Corresponding author: [email protected] ABSTRACT Gas turbines burn a large variety of gaseous fuels under elevated pressure and temperature conditions.
    [Show full text]