— PRODUCT BROCHURE Joslyn Hi-Voltage® Transmaster® VBT furnace 2 TRANSMASTER® VBT ELECTRIC ARC FURNACE SWITCH

— Trusted brand. Quality products.

The operation of electric arc furnaces requires Reliability — reduces stress on equipment large amounts of power to be under constant associated with closing circuit of control. If your only means of controlling • Reduces inrush currents and transients magnetizing, load and secondary associated with transformer switching fault currents was the primary , • Synchronous closing of three switch poles this would result in the circuit breaker being independently, with the occurrence of peak opened and closed more than 100 times per day. voltage in each phase This type of wear and tear would cause even the • Reduces stress on all other components most durable breakers to require frequent and of the furnace costly maintenance. Environmental sustainability — no oil or gases With this in mind, ABB engineers worked closely • Uses vacuum interruption and solid dielectric with electric arc furnace manufacturers to develop insulation for 15 kV to 69 kV applications the Joslyn Hi-Voltage Transmaster VBT electric • Solenoid operating mechanism provides arc furnace switch. The Transmaster switch is a a long life of maintenance-free operations* heavy-duty vacuum switch designed to deliver maintenance-free switching of electric arc Lifecycle cost reductions — with solenoid furnaces. Not only does this switch reduce operators maintenance costs, but it offers reliability, • Long operational life of up to 100,000 open and environmental sustainability and lifecycle cost close operations with no required maintenance* reductions throughout the life of the product. • No monitoring or measuring of oil or gas usage/leakage

*Because it contains no oil or gas to monitor or maintain, the Transmaster switch is considered to be maintenance-free. OVERVIEW 3

— Exceptional value.

— 01 Transmaster Features and benefits Designed specifically for use in: VBT switch • Long, maintenance-free life under demanding • Steel mills — 02 Three single-phase conditions, designed for 100,000 operations • Foundries VBT switch configuration • No oil or gas used for interruption or insulation for use with junction box — • Safe — all exceed the electrical Design 03 Vacuum module requirements of the ANSI C37.66 standard • Solenoid operating mechanism • Vacuum interrupter condition can be determined • 100,000 maintenance-free expected operations quickly by a high-potential withstand test • 60 amp control inrush per mechanism • Lightweight, modular design — no special • 6-cycle trip and close times foundations or costly support required • Compatible with point on wave control (if using • Removable fuses provide protection three single-phase switches) • Vacuum contacts withstand excessive overloads and system short circuits at any power factor Transmaster VBT vacuum module cutaway • Eight heavy-duty auxiliary contacts provided for • Vacuum interrupter designed specifically remote indications, control and interlocking of for repetitive switching other furnace functions or equipment • Contacts/bellows • Capacitor discharge circuit trips switch open • Minimal force required, resulting in longer life upon loss of control voltage • Completely sealed • Circuit trips switch open if one mechanism does • No combustible material not close within the specified time

High-voltage terminal

Epoxy housing

Dead soft copper shunts High-voltage terminal

Solid dielectric Joslyte High-voltage insulation terminal

Porcelain insulator

Pull rod — — — 01 02 03 4 TRANSMASTER® VBT ELECTRIC ARC FURNACE SWITCH

— Ratings

— 01 Operation of • 15 kV to 69 kV electric arc furnaces • Interrupter modules are connected in series • This modular technique allows for higher ratings with the same long-life device and results in common spare parts

— VBT 15 kV–69 kV maximum voltage

Description 15.5 kV 38 kV 48 kV 69 kV Continuous current 600 1000 1500 2000 3000 4000 600 1000 1500 2000 2500 3000 600 1000 1500 2000 2500 3000 300 400 (amps) Momentary current (RMS 20 35 50 65 65 65 20 35 50 65 65 65 20 35 50 65 65 65 15 15 amps, asymmetrical) (kA) Impulse withstand 110 110 110 110 110 110 200 200 200 200 200 200 220 220 220 220 220 220 280 280 open-gap (kV BIL) Impulse withstand line- 150 150 150 150 150 150 200 200 200 200 200 200 250 250 250 250 250 250 350 350 to-ground (kV BIL) Maximum 60-cycle 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 112 245 245 withstand line-to-ground dry (one minute) (kV) Maximum 60-cycle 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 198 198 withstand line-to-ground wet (10 seconds) (kV) Fault interrupting rating 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 (amps, symmetric) (kA)

— 01 RATINGS AND DESIGN ENHANCEMENTS 5

— Design enhancements

— 01 Transmaster Changed from a 300 amp to a 600 amp Added non-evaporable getters VBT switch vacuum interrupter Absorbs gases to maintain constant vacuum Standardized to the 600 amp-rated vacuum integrity and performance. interrupter, which increased vacuum space by 35%. Retested 38 kV Joslyn Hi-Voltage Transmaster VBT — certified Class C2 Electropolish contacts and interrupter stems According to IEEE C37.66, 2005, the Class 2 The addition of this process eliminates all rough certification has the lowest restrike rating and is surfaces and any small imperfections that could defined as 0.2% probability of restrike after 1200 potentially cause partial discharge and could test operations. temporarily impact an electrical interruption performance. This process allows for higher During the testing performed by ABB at a certified voltage conditioning. third-party testing lab; zero restrikes were observed in the 1200-operation test. Voltage withstand testing This testing procedure is performed by reducing the size of the open gap of the contacts and increasing the conditioning voltage in order to better clean the contact surfaces and burn off any initial microscopic particles present during the interrupter manufacturing process. This resulted in an AC withstand test rating of 70 kV for one minute with zero breakdowns.

— 01 6 TRANSMASTER® VBT ELECTRIC ARC FURNACE SWITCH

— Exclusive products and features

— 01 Digital point on Digital point on wave (POW) control Features and benefits wave (POW) control The purpose of the independent pole, point on • Longer equipment life wave, synchronous close system is to reduce • Reduces mechanical forces on transformer transformer energization transients by being able bushings and windings, resulting in lower total to close each pole at the natural current point zero. cost of ownership The expected benefits include significantly • Increased safety reduced inrush currents, reduced electro- • Less electrical stress on transformer mechanical stress on transformer bushings and interwinding insulation windings and reduced stress on all equipment • Reduced maintenance costs associated with the closing circuit of the • Minimal wear on components decreases transformer. In addition, the digital point on wave maintenance requirements control offers the end user the ability to perform • Increased reliability quick and easy calibration themselves, with no • Reduces stress on all other components need to schedule trained outside personnel for of the furnace this task. • Eliminates inrush currents and transients

Application Point on wave closing When an electric arc furnace switch is called on to • Energizes each phase of the transformer close, a random closing occurs, which can energize when the voltage is at a maximum the transformer at any point on the voltage • Since the voltage and current are 90° apart for waveform. This produces high-magnitude transient inductive loads, switching at a maximum voltage inrush currents rated 1000% of full load current. energizes the transformer when a natural current The point on wave control is designed to energize zero would occur the transformer at the optimal point on the voltage waveform.

— 01 DIGITAL POW CONTROL AND SERVICE 7

— Support and service

— 01 Operation of Planned maintenance Planned maintenance services electric arc furnaces • A comprehensive planned maintenance program • Visual inspection provides the best protection for your equipment/ • AC hi-pot testing investment year after year • Contact resistance testing • Service is performed on-site to minimize • Complete mechanical adjustments disruption and downtime • Dynamic timing shots • Use of genuine parts only • High-voltage timing with POW products • Set switches to factory standards • Performance report for each product