GB46-3201 Vacuum Interrupters

Total Page:16

File Type:pdf, Size:1020Kb

GB46-3201 Vacuum Interrupters VACUUM INTERRUPTERS Vacuum Interrupters Outstanding vacuum-related manu- facturing techniques of MEIDEN has completed high preformance and high-reliability vacuum interrupters. Features 1. Simplified arc quenching method The spiral contact assures a high arc driving efficiency. 2. Simplified construction and high quality Since complete degassing and hermetical seal are processed in a vacuum furnace, vacuum degree can be maintained for a long time. 3. No evacuation tube Since manufacturing of vacuum interrupters using ceramics High ability development and outstanding vacuum technology envelopes is done in a vacuum furnace, no evacuation tube of Meidensha Corporation (“MEIDEN”) has estabilished high is necessary. voltage vacuum interrupters. MEIDEN developed a 145kV 4. Slim body Since new contact materials are developed, external dimen- vacuum interrupter unit for the first time in the world. sions are reduced. Major Applications · Vacuum circuit-breakers · Vacuum switches · Vacuum contactors · Transformer tap changers · Rail line circuit-breakers · Autoreclosers · Special duties, e.g. for multi-operation section switches 1 VACUUM INTERRUPTERS VACUUM INTERRUPTERS 2 Vacuum Interrupters *Vacuum Interrupters for Medium Voltage Class Vacuum Interrupters-Structure, Feature & Performance * , Vacuum Interrupters have simple to its structure. Material of copper is used for VI s flanges. Therefore Vacuum Interrupters have IEC & ANSI Standard exellent on heat dissipation at load current and short circuitbreaking current. GB Standard 1. Conducting rod 5. Ceramics envelope 1 2 3 4 5 6 7 8 2. Flange 6. Bellows shield 3. Shield 7. Bellows 4 . Contact and Electrode 8. Twist protection guide MEIDEN is manufacturing the medium voltage class VIs which matches to the various specifications in the world. Automatically forming equipment *Vacuum Interrupters for High Voltage Class MEIDEN developed and commercialized 72.5kV class vacuum interrupter for the first time in the world. MEIDEN has successfully developed a 145kV/40kA rating and turn into production. MEIDEN produces two types of electrode (Spiral & Axial Magnetic Field) and its material is pressed powder of Cr-Cu alloy. *Vacuum Interrupters for Customized Arrangement MEIDEN corresponds to size arrangement and review the specifications of VIs based on requirement. Spiral electrode AMF electrode Production of prottype VIs as well as test of short circuit breaking test, etc are possible. (Soft material) (Hard material) If customer would like to have new R&D and changing for now purches VI, Uniform-dispersion Spiral electrode is normally applied for economic and standard MEIDEN will be possible to test at our own test laboratory for customize arrengement. Cr material within Cu VCB/Swichgear of midium voltage class. MEIDEN manufactures soft electrode by using forming equipment for powder material. *Vacuum Interrupters- Manufacturing & Quality & Assurance All the Vacuum Interrupters assembly works are carried out in a clean room. AMF electrode is applied for high voltage class and capacitor VI contacts are soft and have excellent current-breaking bank. The electrode is hard and have excellent high voltage Each part is chemically cleaned, washed, dried, and then carried to the performance, because of their uniform-dispersion materials. performance. clean room. Vacuum Interrupter using ceramics envelopes has high MEIDEN is manufacturing high voltage VCB upto rated 168kV heat-resisting characteristics. Therefore, it enable to minimize the operating energy for circuit class, and Switchgear at rated 72.5kV class. breakers, and it helps much compact size operating mechanism. Utilizing this advantage, degassing and hermetically sealing procsses are These VCB and Switchgear are using hard material on the vacuum interrupter, its electrode is this hard material. simultaneously carried out in a vacuum furnace. 1000 This simplified manufacturing process makes Vacuum Interrupters quality stable. After brazing under vacuum, each Vacuum Interrupter is to be given ] f a constant mechanical load and then inspected its dimensional variations. All data are automatically recorded under hgih quality control. Data recording and pass-fail judgment are automatically carried out. 100 Minimized contact pressure Inspection of materials supplied and process control at all stage and final inspection of vacuum degree of each vacuum interrupter ensure for quality assurance and a long service life. [kg contact force Total Soft electrode MEIDEN applies a delivery criterion of ultra-high vacuum less than Hard electrode -4 10 5×10 [Pa], thus a service life of VI is 20 years. 12.5 25 50 Breaking current [kArms] 3 VACUUM INTERRUPTERS VACUUM INTERRUPTERS 4 Vacuum Interrupters Vacuum Interrupters for Circuit Breaker <50Hz to 60Hz> Vacuum Interrupters for Load Break Switch Rated Rated Power Rated Short circuit breaking current with Rated Rated Power Rated Short VI Type Voltage lightning frequency Current at least 30-40% DC component and Voltage lightning frequency Current circuit (Dia.-Style) impulse withstand Interrupter (Outdiameter-Style) impulse withstand making voltage Voltage voltage Voltage current kV kV kV A 12.5kA 16kA 20kA 25kA 31.5kA 40kA 50kA kV kV kV A kApeak 7.2 60 20 630 M20QC 12/15.5 95 35 630 40 M01QC (φ52-A) (φ60-A) 24/27 125 60 630 40 M02QC 800/1250 M30RC (φ60-B) (φ94-A) 36/38 150 70 630 40 M03QC 1600/2000 M40SC (φ65-B) (φ94-A) Vacuum Interrupters for Auto-Recloser & Fault Interrupter Switch 2500/3150 M50TC Rated Rated Power Rated Short VI Type (φ110-A) Voltage lightning frequency Current circuit (Dia.-Style) impulse withstand breaking 12/15 75 28 630 M52QC M41QC* MA61RC** voltage Voltage current (φ65-B) (φ69-B) (φ94-B) 800/1250 M51RC kV kV kV A kA (φ82-B) 15.5/27 110/125 50/60 630 12.5 M52QC* (φ65-B) 1600/2000 M71SC M81SC (φ94-B) (φ110-B) 15.5/27 110/125 50/60 800 16 M72QC* (φ75-B) 2500/3150 M71TC M81TC MA131TC 38 150 70 630 12.5 M83QC* (φ110-B) (φ132-B) (φ150-B) (φ75-B) 17.5/24 95/125 38/50 630 M52QC* MA102RC** 38 150 70 800 16 MA93QC* (φ65-B) (φ94-B) (φ82-B) 800/1250 M72RC* M82RC* M102RC Vacuum Interrupters for Contactor Switch (φ75-B) (φ75-B) (φ94-B) Rated Rated Power Rated Short VI Type 1600/2000 M102SC Voltage lightning frequency Current circuit (Dia.-Style) (φ94-B) impulse withstand breaking voltage Voltage current 2500 M132TC M203TC kV kV kV A kA (φ120-B) (φ120-C) 6.6 45 16 400 4 5G-1 36/38 175 80 630 M83QC* M93QC* (φ52-A) (φ75-B) (φ94-B) 6.6 45 16 400 6 7.5G 800/1250 M123RC* (φ52-A) (φ94-B) 1600/2000 M163SC* Vacuum Interrupters for Mobile Railway Interrupter Switch (φ110-B) Rated Rated Power Rated Short Short VI Type Voltage lightning frequency Current circuit circuit (Dia.-Style) 2500 M203TCB* M253TC* impulse withstand breaking making (φ120-C) (φ132-C) voltage Voltage current current 52 250 90 1250/2000 MA285SC* kV kV kV A kA kA (φ132-B) 18/36 170 70(16.6Hz) 750(16.6Hz) at 18kV at 18kA 163SCM → → 72.5 325 140 1250/2000 MA317SC* MA467SC* MA507SC* 70(50/60Hz) 450(50/60Hz) 25(16.6Hz) 62.5(16.6Hz) (φ132-C) (φ132-B) (φ150-B) (φ150-B) at 36kV →20(50/60Hz) * : Additional external insulation necessary 1,000,000 M31QC **: Capacitor bank switching *Diameter M52QC M41RC Interrupter types and diameters are shown in the tables. 100,000 M51RC & M61RC → M71SC M81TC MA131TC 10,000 1,000 100 Number of oparations [times] 10 1 0.1 1 10 100 Breaking current [kA (r.m.s)] → Style A Style B Style C ELECTRICAL LIFE (12/15kV Class Vacuum Interrupter) 5 VACUUM INTERRUPTERS VACUUM INTERRUPTERS 6 ThinkPark Tower, 2-1-1, Osaki, Shinagawa-ku, Tokyo, 141-6029 Japan www.meidensha.com Overseas Offices & Group Companies China Myanmar Meiden Zhengzhou Electric Co., Ltd. Thai Meidensha Co.,Ltd. Yangon Branch Meidensha (Shanghai) Corporate Management Co., Ltd. Singapore Meiden Hangzhou Drive System Co., Ltd. Meiden Asia Pte. Ltd. Shanghai Meidensha Changcheng Switchgear Co., Ltd. Meiden Singapore Pte. Ltd. Meiden (Hangzhou) Drive Technology Co., Ltd. Thailand Hong Kong Thai Meidensha Co., Ltd. Meiden Pacific (China) Ltd. Meiden Electric (Thailand) Ltd. India Vietnam Meiden India Pvt. Ltd. Meiden Singapore Pte. Ltd. Hanoi Office Meiden India Pvt. Ltd. Ahmedabad Branch Philippines Indonesia Meiden Singapore Pte. Ltd. Philippines Branch P.T. Meiden Engineering Indonesia United Arab Emirates Korea Meiden Asia Pte. Ltd. Dubai Branch Meiden Korea Co., Ltd. Germany Malaysia Meiden Europe GmbH. Meiden Malaysia Sdn.Bhd. Tridelta Meidensha GmbH. Meiden Metal Engineering Sdn. Bhd. The United States Meiden America, Inc. Meiden America Switchgear, Inc. Specifications in this catalog are subject to change without notice. GB46-3201BXX00-0000X As of Nov.,Jan., 20182020 The seller shall not be liable for incidental damages, consequential 2022018-1ME0-11ME((0.0V4L)0.5L0.0L damages including loss of profit and special damages..
Recommended publications
  • Medium-Voltage Vacuum Generator Circuit Breaker Switchgear
    Medium-voltage vacuum generator circuit breaker switchgear Siemens offers a fully customizable • Uses the latest developments in • Significantly lower life cycle costs stationary type vacuum generator vacuum interrupter axial-magnetic due to: circuit breaker switchgear tested to field (AMF) technology • Reduced inspection and IEEE C37.013. Each design is engineered • Highly reliable vacuum interrupters – maintenance costs to meet the specific electrical and MTTF over 50,000 years mechanical application requirements • Maintenance-free, stored- of the project. • Highly reliable spring-drive energy (spring) operator. operating mechanism due to use of • All medium-voltage switching • Optional start-up disconnector for common type 3AH3 operator components, including the vacuum connection to SFC platform generator circuit breaker, are • Connections to generator and mounted on a removable, fully- • Over 120,000 type 3AH3 operators step-up transformer using isolated- integrated, compact switching produced since 1998 and over phase bus (not furnished) module for each pole 25,000 operators produced per year • Current and voltage transformers • Continuous current ratings of available to suit specifications 6,300 A, 8,000 A, 10,000 A, • 10,000 continuous current and 12,500 self-cooled switching operations • Surge arresters and surge capacitors optionally available. • Interrupting ratings of 80 kA • Complete switchgear shipped as and 100 kA one final-assembled unit • Maximum design voltage up to 24 kV • Tested to IEEE C37.013 standard for generator
    [Show full text]
  • GE Power/Vac 7 Vacuum Distribution Recloser
    GE Power Switching & Controls GE Power/Vac 7 Vacuum Distribution Recloser Power/Vac7 Type PVDR 15.5 kV and 27.0 kV Three Phase Vacuum Circuit Recloser GE Power Switching & Controls Introduces Power/Vac Vacuum Distribution Recloser An addition to the proven vacuum distribution product line. The GE Distribution Recloser is a • Reliable Arc Interruption Power/Vac (in-air), Type PVDR, four Arc interruption typically occurs at shot recloser for use in applications the first current zero after contact on distribution systems. separation. The high dielectric strength of the vacuum gap results The Vacuum (in-air) Distribution in an extremely short clearing time. recloser is available as a standard From a normal CLOSED position, offering utilizing the GE-Multilin F650- the recloser can complete fault Recloser Controller. This controller interruption in five cycles. package utilizes the Multi-function F650 relay, 10-pole test switch, 24 vdc battery • Long Service Life with charger (when station DC is not Power/Vac interrupters experience available), and a 120VAC GF-protected no significant contact erosion during receptacle. (Other relay configurations normal duty. They are designed and are available.) tested to meet or exceed performance requirements of applicable ANSI, The Type PVDR Recloser is rated 15.5 IEEE and NEMA standards. kV and 27.0 kV. They are high speed vacuum (in-air) reclosers designed to meet increased demands for uninter- • Low Maintenance rupted power on distribution circuits The Power/Vac interrupter element requiring single or multi-shot reclosing. is designed for 10,000 no-load and The PVDR is capable of interrupting at 5,000 full load operations prior to either 10,000, 12,000 or 16,000 amperes maintenance.
    [Show full text]
  • Slac-169 Uc -38 Vacuum Circuit Breaker for Power System
    SLAC-169 UC -38 VACUUM CIRCUIT BREAKER FOR POWER SYSTEM APPLICATION* ALEXANDER AN-SHENG TSENG STANFORD LINEAR ACCELERATOR CENTER STANFORD UNIVERSITY Stanford, California 94305 PREPARED FOR THE U.S. ATOMIC ENERGY COMMISSION UNDER CONTRACT NO. AT (04-3) -515 March 1974 Printed in the United States of America. Available from National Technical Service, U.S. Department of Commerce, 5285 Port Royal Road, Springfield Virgiriia 22151. Price: Printed Copy $4.00; Microfiche $1.45. * Engineer, Electrical Engineering thesis. ABSTRACT The application of vacuum circuit breaker to the power system for switching on-off a large load and/or a large power supply plus the need of short circuit protection by the same circuit breaker requires a better understanding of the high-current vacuum arcs, electrode phenom- enon and power system circuit constants under which the vacuum circuit breaker is applied. This thesis is devoted to the fol lowing areas: I) History of Vacuum Circuit Breaker Development, 2) Major Electric Characteristics of Vacuum Circuit Breaker such as Spark-over Voltage Levels vs. Contact Spacing, Spark-over Voltage vs. Vacuum Pressure, Cold Field Emission, Temperature Rise from Field Emission, Vacuum Pump Action in Vacuum Switches, Vacuum Pressure Maintained Over Long Time Periods, Switching and Recovery Voltage Characteristics, 3) Contact Materials, the Physical Mechanism of Current Chopping and How it is Influenced by the Physical Properties of the Contact Materia I, 4) Better Understanding of High Current Vacuum Arcs, and 5) The Initia and Operating Experiences of Vacuum Circuit Breakers Used on Eight I 5kv Large Solid State Power Supplies Ranging from l.5MW to 5.8MW.
    [Show full text]
  • Impact of De-Energization of 33Kv Harmonic Filter on TRV of Vacuum Circuit Breakers
    Impact of De-Energization of 33kV Harmonic Filter on TRV of Vacuum Circuit Breakers P. Marini Abstract—In some oil & gas plants, 33 kV large harmonic the vacuum circuit breaker used to switch the harmonic filter filters are needed for the aim of both compensating the overall [3]: especially for low order (e.g. the 3rd) harmonic filters, it power factor of the plant and for filtering the harmonic current can happen that the minimum 36 kV rated insulation level distortion caused by the variable speed drives. commonly foreseen by IEC standards [4], is no longer In case of the de-energization of the filter bank by means of the switching of a vacuum circuit breaker, the vacuum sufficient to guarantee that the TRV of the circuit breaker be interrupter is subject to a great dielectric stress when the voltage not exceeded, but it is necessary to select 40.5 kV as rated recovers at its terminals: the reason of this particularly high insulation level: a new study approach, non existing in the stress lies in the series connection of the reactor coil with the literature, is here presented in order to assess the filter de- capacitor in order to realize the proper harmonic filter order. energization and to ensure that the insulation rating of the Consequently, it can happen that the rated peak value of the vacuum circuit breaker is correctly determined. transient recovery voltage (TRV) of the vacuum circuit breaker is exceeded. Useful considerations, based on IEC standards for high II. SYSTEM DATA AND MODELING voltage circuit breakers as well as on laboratory tests performed on vacuum interrupters by switchgear manufacturer, are carried A.
    [Show full text]
  • Vacuum Switching Technology and Components for Medium Voltage · Siemens HG 11.01 · 2016 Contents
    Catalog Vacuum Switching Technology and HG 11.01 Edition 2016 Components for Medium Voltage Your Guide siemens.com/mediumvoltage SION 3AE 3AH5 3AK 3AH36/37/38 3AF0 outdoor circuit-breaker generator circuit-breaker 3TL vacuum contactor (live tank) SDV outdoor circuit-breaker (dead tank) 3AD recloser 3AD8 Fusesaver 3EF surge limiter / 3EK4 surge arrester 3GD fuses 3SV9 auxiliary switches 2 Vacuum Switching Technology and Components for Medium Voltage · Siemens HG 11.01 · 2016 Contents Vacuum Switching Page Technology and Introduction to medium-voltage components 4 Components for Overview of medium-voltage components Switching devices, non-switching components 5 Medium Voltage Vacuum interrupter technology in detail 6 Medium-Voltage Equipment Selection of components by switching applications Switching applications with undisturbed operation 8 Switching applications with disturbed operation 9 Catalog HG 11.01 · 2016 Ratings for medium-voltage equipment Invalid: Catalog HG 11.01 · 2007 Stress caused by network operation 10 Standards 11 www.siemens.com/mediumvoltage Medium-voltage equipment for indoor applications Vacuum circuit-breakers 12 Application, switching duties, designs, portfolio Switch-disconnectors 18 Application, quenching principle, designs, portfolio Vacuum contactors, 19 contactor-fuse combination Application, switching duties, designs, portfolio Partnering 21 Medium-voltage equipment for outdoor applications Outdoor vacuum circuit-breakers 22 Application, switching duties, live-tank and dead-tank designs, portfolio Recloser 24 Application, switching duties, designs, portfolio Fusesaver 26 Application, designs, portfolio, mode of operation Medium-voltage equipment Surge arresters and limiters 28 Application, designs, portfolio Fuses 29 Application, designs, portfolio Protection and measuring transformers 30 Application, designs, portfolio Auxiliary switches 31 Application, properties Guide The products and systems described in this catalog Catalog overview 32 are manufactured and sold according to a certified management system (acc.
    [Show full text]
  • The Peculiarities of Transient Recovery Voltage in Presence Of
    XXIVth Int. Symp. on Discharges and Electrical Insulation in Vacuum - Braunschweig - 2010 The Peculiarities of Transient Recovery Voltage in Presence of Post Arc Current in Vacuum Circuit Breakers Amir Hayati Soloot1, Edris Agheb1, Jouya Jadidian2, Hans Kristian Hoidalen1 1 Department of Electrical Power Eng., Norwegian Uni. of Sci. and Tech. (NTNU), O.S. Bragstadspl. 2F, Trondheim N-7491, Norway. 2 Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology Cambridge, MA 02142, USA Abstract- The post arc phase is a critical part in the current interruption [1]. The role of metal vapor, gas and molten interruption process of Vacuum Circuit Breakers (VCB). electrode surfaces [2]-[3], cathode material [4]-[5], During this step, the dielectric strength of VCB has to be plasma density [6]-[9], interrupted current amplitude [9], recovered. In order to improve the performance of VCB, and arcing time [1], [9], [11] is discussed in relation to investigation of Post Arc Current (PAC) in the presence of post arc phenomenon of VCBs. The impact of PAC on Transient Recovery Voltage (TRV) is presented in this breakdown strength after current zero is discussed and paper. evaluated in [10]. The equations of ion sheath length and PAC are solved Since the VCBs are operated for various applications together with network equations, which describe the TRV like capacitive switching [12] and the switching of high and PAC interrelation. In order to solve nonlinear ion voltage high power inductive motors [13], the sheath equations simultaneously with PAC and TRV investigation of post arc phenomenon for these equations, a Gauss-Seidel method is applied.
    [Show full text]
  • Substation Vacuum Circuit Breaker (15.5Kv)
    Guide Specification Updated 12/2017 SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities and other high demand industries. By combining the latest developments in circuit breaker technology with world- renowned quality, the Powersub™ Type FVR Vacuum Substation Circuit Breakers from Myers Controlled Power are the most advanced medium-voltage circuit breakers available. Part 1: General This specification applies to an outdoor, three pole, single throw, free standing, 15.5 kV vacuum circuit breaker. A. References • ANSI/IEEE C37.20.2 - Standard for Metal-Clad and Station-Type Cubicle Switchgear. • ANSI/IEEE C37.04 and .06 - Standard ratings and preferred ratings for Class S2 Outdoor AC Medium-Voltage Circuit Breakers. • ANSI/IEEE C37.11 - Requirements for electrical control for AC High-Voltage Circuit Breakers rated on a symmetrical current basis or a total current basis. • ANSI/IEEE C37.09 - Standard Design and Production Testing • ANSI Z55.1 - Gray Finishes for Industrial Apparatus and Equipment. • ANSI/IEEE C57.13 - Requirements for Instrument Transformers. • NEMA SG4 - Alternating Current High Voltage Circuit Breakers. B. Submittals Submit shop drawings indicating outline dimensions, enclosure construction, shipping splits, lifting and supporting points, electrical single line diagram, and equipment electrical ratings. C. Operation and Maintenance Data Include circuit breaker recommended spare parts list. D. Quality Assurance Qualified manufacturer shall be a company specializing in medium voltage substation vacuum station breakers with at least five years documented experience. The breaker shall be manufactured in a facility that is Quality Systems Registered by Underwriters Laboratories, Inc.
    [Show full text]
  • CIRED 2019 1/5 25Th International Conference on Electricity Distribution Madrid, 3-6 June 2019
    25th International Conference on Electricity Distribution Madrid, 3-6 June 2019 Paper n° 883 HIGH PERFORMANCE SMART MV APPARATUS FOR ARC FURNACE APPLICATIONS Andrea BIANCO Bill BREWER Martin STEFANKA Marco RIVA ABB spa, Italy Nucor SMG P, Arkansas (US) ABB s.r.o. Brno, CZ ABB spa, Italy [email protected] [email protected] [email protected] [email protected] ABSTRACT The heavy-duty cycle of operation in the harsh environment asks for extensive electrical and mechanical Steel manufacturing represents a critical application for performance of the devices combined with the ability to control processes and apparatuses. In particular, allow smart containment of current and voltage switching of the Electric Arc Furnace (EAF) transformer overvoltage transients. are recognized as challenging for reliability of the Severe degradation of the arc furnace transformer insulation is the result of overvoltages arising from voltage switching devices needed for relentless furnace operation. circuit breaker opening [2]. The Medium voltage Circuit Breaker is required to cope The standard proposed solution to damping of the up with hundreds of close/open operations per day, limited overvoltages and to protection from the effect of virtual maintenance and minimum number of downtimes, current chopping can be sought with the use of a protective operations in harsh environment. RC surge suppressor unit installed near the arc furnace In order to support safe and relentless operation and transformer together with surge arresters installed on the protection a dedicated circuit breaker based on vacuum main transformer secondary and arc furnace transformer technology and innovative actuation systems has been primary terminals [3].
    [Show full text]
  • Medium-Voltage Vacuum Circuit Breakers
    Eaton’s Cooper Power Systems catalog Medium-voltage vacuum circuit breakers Medium-voltage vacuum circuit breakers Catalog information Medium-voltage vacuum circuit breakers catalog Technical Data Effective August 2014 Medium-voltage vacuum circuit breakers catalog contents Contents Description Page Type VSA20B air-insulated; vacuum; electronically controlled power circuit breaker (290-25) ......................................... 3 www.cooperpower.com Effective May 2014 Technical Data 290-25 Supersedes June 1995 Type VSA20B air-insulated; vacuum; electronically controlled power circuit breaker Description The Type VSA20B electronically controlled, vacuum circuit breaker provides reliable and economical overcurrent protection for 15 kV distribution systems. The VSA20B circuit breaker has been full-power tested in accordance with ANSI® and NEMA® standards for power circuit breakers. Detailed ratings and related capabilities on a symmetrical current basis, using maximum design voltage and a K factor of 1.0, are shown in Table 1. The VSA20B circuit breaker has a rated interrupting time of 2.5 cycles in accordance with ANSI® stan- dards. The fast interrupting time minimizes fault damage and provides fast coordination capability. A choice of electronic controls enables the user to meet a wide variety of application requirements. The use of vacuum as the interrupting medium and air as the insulating medium improves safety and substantially reduces long term maintenance costs. The VSA20B circuit breaker provides service-proven dependability and long operating life. Commanded by an Eaton's Cooper Power Systems electronic control, this automatic circuit breaker offers superior coordination and application capability, unmatched by other system protection apparatus. Breaker operations are programmed on the electronic control panel with accurate, preset tripping characteristics and reclosing times, enabling close coordination with other protective devices on the system.
    [Show full text]
  • GB46-3201 Vacuum Interrupters
    VACUUM INTERRUPTERS Vacuum Interrupters Outstanding vacuum-related manu- facturing techniques of MEIDEN has completed high preformance and high-reliability vacuum interrupters. Features 1. Simplified arc quenching method The spiral contact assures a high arc driving efficiency. 2. Simplified construction and high quality Since complete degassing and hermetical seal are processed in a vacuum furnace, vacuum degree can be maintained for a long time. 3. No evacuation tube Since manufacturing of vacuum interrupters using ceramics High ability development and outstanding vacuum technology envelopes is done in a vacuum furnace, no evacuation tube of Meidensha Corporation (“MEIDEN”) has estabilished high is necessary. voltage vacuum interrupters. MEIDEN developed a 145kV 4. Slim body Since new contact materials are developed, external dimen- vacuum interrupter unit for the first time in the world. sions are reduced. Major Applications · Vacuum circuit-breakers · Vacuum switches · Vacuum contactors · Transformer tap changers · Rail line circuit-breakers · Autoreclosers · Special duties, e.g. for multi-operation section switches 1 VACUUM INTERRUPTERS VACUUM INTERRUPTERS 2 Vacuum Interrupters *Vacuum Interrupters for Medium Voltage Class Vacuum Interrupters-Structure, Feature & Performance * , Vacuum Interrupters have simple to its structure. Material of copper is used for VI s flanges. Therefore Vacuum Interrupters have IEC & ANSI Standard exellent on heat dissipation at load current and short circuitbreaking current. GB Standard 1. Conducting rod 5. Ceramics envelope 1 2 3 4 5 6 7 8 2. Flange 6. Bellows shield 3. Shield 7. Bellows 4 . Contact and Electrode 8. Twist protection guide MEIDEN is manufacturing the medium voltage class VIs which matches to the various specifications in the world.
    [Show full text]
  • Experimental Investigation of the Prestrike Characteristics of a Double-Break Vacuum Circuit Breaker Under DC Voltages
    energies Article Experimental Investigation of the Prestrike Characteristics of a Double-Break Vacuum Circuit Breaker under DC Voltages Yun Geng 1, Xiaofei Yao 1,*, Jinlong Dong 1,* , Xue Liu 1, Yingsan Geng 1, Zhiyuan Liu 1, Jing Peng 2 and Ke Wang 2 1 State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, No.28 Xianning West Road, Xi’an 710049, China; [email protected] (Y.G.); [email protected] (X.L.); [email protected] (Y.G.); [email protected] (Z.L.) 2 Electric Power Research Institute, Yunnan Power Grid Co. Ltd., No.105 Yunda West Road, Kunming 650217, China; [email protected] (J.P.); [email protected] (K.W.) * Correspondence: [email protected] (X.Y.); [email protected] (J.D.); Tel.: +86-029-82663773 (J.D.) Received: 1 May 2020; Accepted: 16 June 2020; Published: 20 June 2020 Abstract: The prestrike phenomenon in vacuum circuit breakers (VCBs) is interesting but complicated. Previous studies mainly focus on the prestrike phenomenon in single-break VCBs. However, experimental work on prestrike characteristics of double-break VCBs cannot be found in literature. This paper aims to experimentally determine the probabilistic characteristics of prestrike gaps in a double-break VCB consisting of two commercial vacuum interrupters (VIs) in series under direct current (DC) voltages. As a benchmark, single-break prestrike gaps were measured by short-circuiting one of the VIs in a double break. The experimental results show that the 50% prestrike gap d50 of each VI in a double break, which is calculated with the complementary Weibull distribution, was significantly reduced by 25% to 72.7% compared with that in a single break.
    [Show full text]
  • WC / Ag Contact Materials with Improved Homogeneity
    200 RM 20 R. Grill et al. WC / Ag Contact Materials with Improved Homogeneity Robert Grill1, Peter Kläusler ², Frank E.-H. Mueller², Oswald Schrott³, Hans Hauser ³ 1 Plansee Aktiengesellschaft, A-6600 Reutte, ² Elektro-Metall, CH-5703 Seon ³ TU-Wien, Institut für industrielle Elektronik und Materialwissenschaften, A-1040 Wien Summary For low voltage switches and specific medium voltage vacuum bottles (7,1 kV / 4 kA) the contact material of choice is WC/Ag with respect to erosion resistance, chopping current and lifetime. All industrial manufacturing processes, which are established, are based on powder metallurgical manufacturing technologies. Besides the mechanical and physical properties of the contact material, the microstructure and homogeneity are essential for the arcing behaviour of the contacts in service. For WC/Ag 60/40 contact material different treatment techniques for preparation of powder mixtures (Mixing, ball milling, planetary ball milling) to improve the homogeneity were investigated. For consolidation of samples the press – sinter – infiltration route was used and by use of micrographs an assessment with respect to homogeneity of microstructure was made. With planetary ball milling homogeneity of WC/Ag 60/40 can be improved without disadvantages on WC particle size and handle- ability of powder mixture. The observed differences in microstructure have no influence on the physical properties of the contact material. Keywords Contact Material, Tungsten-Carbide Silver, Powder Metallurgy, Microstructure, Homogeneity R. Grill et al. RM 20 201 1. Introduction Electrical switchgears are used in the fields of power generation, transmission, distribution, and consumption. Today, vacuum switches (up to 52 kV) are the most important switchgears for power distribution.
    [Show full text]