The Innovative Concept of Cold District Heating Networks: a Literature Review
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Investigating Hidden Flexibilities Provided by Power-To-X Consid- Ering Grid Support Strategies
InVESTIGATING Hidden FleXIBILITIES ProVIDED BY Power-to-X Consid- ERING Grid Support StrATEGIES Master Thesis B. Caner YAgcı˘ Intelligent Electrical POWER Grids Investigating Hidden Flexibilities Provided by Power-to-X Considering Grid Support Strategies Master Thesis by B. Caner Yağcı to obtain the degree of Master of Science at the Delft University of Technology, to be defended publicly on Tuesday September 14, 2020 at 9:30. Student number: 4857089 Project duration: December 2, 2019 – September 14, 2020 Thesis committee: Dr. Milos Cvetkovic, TU Delft, supervisor Dr. ir. J. L. Rueda Torres, TU Delft Dr. L. M. Ramirez Elizando TU Delft This thesis is confidential and cannot be made public until September 14, 2020. An electronic version of this thesis is available at http://repository.tudelft.nl/. Preface First of all, I would like to thank PhD. Digvijay Gusain and Dr. Milos Cvetkovic for not only teaching me the answers through this journey, but also giving me the perception of asking the right questions that lead simple ideas into unique values. I would also like to thank my family Alican, Huriye, U˘gur, Gökhan who have been supporting me from the beginning of this journey and more. You continue inspiring me to find my own path and soul, even from miles away. Your blessing is my treasure in life... My friends, Onurhan and Berke. You encourage me and give me confidence to be my best in any scene. You are two extraordinary men who, I know, will always be there when I need. Finally, I would like to thank TU Delft staff and my colleagues in TU Delft for making this journey enter- taining and illuminative for me. -
Consider Installing a Condensing Economizer, Energy Tips
ADVANCED MANUFACTURING OFFICE Energy Tips: STEAM Steam Tip Sheet #26A Consider Installing a Condensing Economizer Suggested Actions The key to a successful waste heat recovery project is optimizing the use of the recovered energy. By installing a condensing economizer, companies can im- ■■ Determine your boiler capacity, prove overall heat recovery and steam system efficiency by up to 10%. Many average steam production, boiler applications can benefit from this additional heat recovery, such as district combustion efficiency, stack gas heating systems, wallboard production facilities, greenhouses, food processing temperature, annual hours of plants, pulp and paper mills, textile plants, and hospitals. Condensing economiz- operation, and annual fuel ers require site-specific engineering and design, and a thorough understanding of consumption. the effect they will have on the existing steam system and water chemistry. ■■ Identify in-plant uses for heated Use this tip sheet and its companion, Considerations When Selecting a water, such as boiler makeup Condensing Economizer, to learn about these efficiency improvements. water heating, preheating, or A conventional feedwater economizer reduces steam boiler fuel requirements domestic hot water or process by transferring heat from the flue gas to the boiler feedwater. For natural gas-fired water heating requirements. boilers, the lowest temperature to which flue gas can be cooled is about 250°F ■■ Determine the thermal to prevent condensation and possible stack or stack liner corrosion. requirements that can be met The condensing economizer improves waste heat recovery by cooling the flue through installation of a gas below its dew point, which is about 135°F for products of combustion of condensing economizer. -
4Th Generation DHC Technology Guide
4DHC technology guide 1 4DHC technology guide Researched by Checked by Reviewed by First Draft Final Draft Joseph Maria September 2019 Jebamalai Marijke Mahieu September 2019 Dirk Hoet October 2019 Author(s): Joseph Maria Jebamalai, Ghent University Email: [email protected] Phone: 32 (0) 487 94 98 47 Address: St. Pietersnieuwstraat 33, 9000 Gent Deliverable: WP.T3 D1.4 4DHC technology guide Date: September 2019 About HeatNet NWE This document has been developed as part of the HeatNet NWE project, which is part-funded through the Interreg NWE programme and aims to increase the uptake of 4DHC networks across North-West Europe. As part of this project, the partners are developing the HeatNet Model, which will help the public sector to begin implementing 4DHC networks, and the Transition Roadmaps, which will outline the partners’ experience in developing six district heating pilots across North-West Europe. The HeatNet Guide to Financing is also currently being developed and will give a broad overview of the various sources available to finance district heating schemes. For further information on these reports and on the HeatNet NWE project, please visit www.guidetodistrictheating.eu. 2 4DHC technology guide Table of contents Executive summary 4 Introduction 5 What is DHC? 5 Why 4DHC? 5 About 4DHC 6 Benefits of 4DHC 7 4DHC Systems: Technology Options 8 Low temperature waste heat 8 Solar thermal systems 15 Heat pumps 18 Geothermal systems 20 Cascading networks 24 Combined district heating and cooling systems 27 Combi-systems 28 4DHC components 28 Distribution pipes 35 Storage tanks 36 Pumps 37 Monitoring systems 37 Conversion of existing DH into 4DHC 38 Future of DHC 40 Conclusion 41 3 4DHC technology guide Executive summary This technology guide aims to help stakeholders involved in 4th generation district heating and cooling (4DHC) projects to understand the different sustainable technologies for the development of future-proof and efficient 4DHC networks. -
Overview of Chiller Compressors
Overview of Chiller Compressors Course No: M04-027 Credit: 4 PDH A. Bhatia Continuing Education and Development, Inc. 22 Stonewall Court Woodcliff Lake, NJ 07677 P: (877) 322-5800 [email protected] OVERVIEW OF CHILLER COMPRESSORS Overview In HVAC industry, the refrigeration machine that produces chilled water is referred to as a “Chiller”. A chiller package operates either on the principles of vapor compression or vapor absorption. The vapor compression system uses mechanical energy in the form of electric motor to drive the cooling cycle whereas absorption chillers use heat to drive the process. The vapor compression chiller system, which is far more prominent in commercial buildings, consists of four major components: the compressor, evaporator, condenser and expansion device all packaged as a single unit. The classification of vapor compression chiller packages is generally by the type of compressor: centrifugal, reciprocating, and screw being the major ones. Chillers are the largest consumer of energy in a commercial building and it is therefore important to understand the relative benefits and limitations of various types in order to make the right economic decisions in chiller installation and operation. This course will talk about the type of compressor used in the water cooled chiller. The course is divided into 3 parts: Part - I: Types of Chiller Compressors Part – II: Comparison of Chiller Compressors Part –III: Economic Evaluation of Chiller Systems PART I - TYPES OF CHILLER COMPRESSORS Most cooling systems, from residential air conditioners to large commercial and industrial chillers, employ the refrigeration process known as the vapor compression cycle. At the heart of the vapor compression cycle is the mechanical compressor. -
District Heating System, Which Is More Efficient Than
Supported by ECOHEATCOOL Work package 3 Guidelines for assessing the efficiency of district heating and district cooling systems This report is published by Euroheat & Power whose aim is to inform about district heating and cooling as efficient and environmentally benign energy solutions that make use of resources that otherwise would be wasted, delivering reliable and comfortable heating and cooling in return. The present guidelines have been developed with a view to benchmarking individual systems and enabling comparison with alternative heating/cooling options. This report is the report of Ecoheatcool Work Package 3 The project is co-financed by EU Intelligent Energy Europe Programme. The project time schedule is January 2005-December 2006. The sole responsibility for the content of this report lies with the authors. It does not necessarily reflect the opinion of the European Communities. The European Commission is not responsible for any use that may be made of the information contained therein. Up-to-date information about Euroheat & Power can be found on the internet at www.euroheat.org More information on Ecoheatcool project is available at www.ecoheatcool.org © Ecoheatcool and Euroheat & Power 2005-2006 Euroheat & Power Avenue de Tervuren 300, 1150 Brussels Belgium Tel. +32 (0)2 740 21 10 Fax. +32 (0)2 740 21 19 Produced in the European Union ECOHEATCOOL The ECOHEATCOOL project structure Target area of EU28 + EFTA3 for heating and cooling Information resources: Output: IEA EB & ES Database Heating and cooling Housing statistics -
Technical Challenges and Innovative Solutions for Integrating Solar Thermal Into District Heating
Solar Energy Systems GmbH Technical challenges and innovative solutions for integrating solar thermal into district heating P. Reiter SOLID Solar Energy Systems GmbH 06.12.2019 Solar Energy Systems GmbH Solar Heat and DH Solar Cooling Solare Process Heat 26 YEARS EXPERIENCE IN LARGE-SCALE SOLAR THERMAL 300 SYSTEMS BUILT IN MORE THAN 20 COUNTRIES OFFICES IN THE USA, SINGAPORE, GERMANY Energy used by sector: heat - mobility - electricity Solar Energy Systems GmbH Renewable Energy in Total Final Energy Consumption, by Sector, 2016; Source: REN21 Global Status Report 2019 Current supply of DH worldwide Solar Energy Systems GmbH Werner (2017), https://doi.org/10.1016/j.energy.2017.04.045 Energy mix of the future Solar Energy Systems GmbH Limited renewable electricity More wind needed to cover Seasonal current electricity demand mismatch Limited availability Recycling reduces energy from waste Industry tries Operation based on to reduce Limited electricity needs => waste heat availability does not match heat profile Differences between basic SDH and BigSolar Solar Energy Systems GmbH Basic solar district heating (SDH) for covering DHW demand Current SDH systems for covering summer DHW demand Solar Energy Systems GmbH AEVG/Fernheizwerk, Graz, AT Collector field test under real conditions! 10 collector types from 7different manufacturers: • HT-flat plate collectors (foil/double glass) Commiss Collector Nominal Solar CO2- ioning surface power yield savings • Vacuum-tube collectors area Heat • Concentrating collector 2007 8,215 m² 5.7 MW ca. 3,000 1,400 t / 2014-18 MWh/a year Differences between basic SDH and BigSolar Solar Energy Systems GmbH Solar district heating including seasonal storage (BigSolar) Scenario 2 The BigSolar concept Solar Energy Systems GmbH CITYCITY Boiler Boiler Potentials with high solar coverage ratios Solar Energy Systems GmbH SDH for DHW in summer BigSolar (incl. -
Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control
energies Article Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control Simone Buffa 1,*, Anton Soppelsa 1 , Mauro Pipiciello 1, Gregor Henze 2,3,4 and Roberto Fedrizzi 1 1 Eurac Research, Institute for Renewable Energy, Viale Druso 1, 39100 Bolzano, Italy; [email protected] (A.S.); [email protected] (M.P.); [email protected] (R.F.) 2 Department of Civil, Environmental and Architectural Engineering, University of Colorado Boulder, Boulder, CO 80309-0428, USA; [email protected] 3 National Renewable Energy Laboratory, Golden, CO 80401, USA 4 Renewable and Sustainable Energy Institute, Boulder, CO 80309, USA * Correspondence: simone.buff[email protected]; Tel.: +39-0471-055636 Received: 16 July 2020; Accepted: 11 August 2020; Published: 21 August 2020 Abstract: District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. -
4. Hvac and Refrigeration System
4. HVAC AND REFRIGERATION SYSTEM Syllabus HVAC and Refrigeration System: Vapor compression refrigeration cycle, Refrigerants, Coefficient of performance, Capacity, Factors affecting Refrigeration and Air conditioning system performance and savings opportunities. Vapor absorption refrigeration system: Working principle, Types and comparison with vapor compression system, Saving potential 4.1 Introduction The Heating, Ventilation and Air Conditioning (HVAC) and refrigeration system transfers the heat energy from or to the products, or building environment. Energy in form of electricity or heat is used to power mechanical equipment designed to transfer heat from a colder, low-ener- gy level to a warmer, high-energy level. Refrigeration deals with the transfer of heat from a low temperature level at the heat source to a high temperature level at the heat sink by using a low boiling refrigerant. There are several heat transfer loops in refrigeration system as described below: Figure 4.1 Heat Transfer Loops In Refrigeration System In the Figure 4.1, thermal energy moves from left to right as it is extracted from the space and expelled into the outdoors through five loops of heat transfer: – Indoor air loop. In the leftmost loop, indoor air is driven by the supply air fan through a cool- ing coil, where it transfers its heat to chilled water. The cool air then cools the building space. – Chilled water loop. Driven by the chilled water pump, water returns from the cooling coil to the chiller’s evaporator to be re-cooled. – Refrigerant loop. Using a phase-change refrigerant, the chiller’s compressor pumps heat from the chilled water to the condenser water. -
Performance Prediction of a Solar District Cooling System in Riyadh, Saudi T Arabia – a Case Study ⁎ G
Energy Conversion and Management 166 (2018) 372–384 Contents lists available at ScienceDirect Energy Conversion and Management journal homepage: www.elsevier.com/locate/enconman Performance prediction of a solar district cooling system in Riyadh, Saudi T Arabia – A case study ⁎ G. Franchini , G. Brumana, A. Perdichizzi Department of Engineering and Applied Sciences, University of Bergamo, 5 Marconi Street, Dalmine 24044, Italy ARTICLE INFO ABSTRACT Keywords: The present paper aims to evaluate the performance of a solar district cooling system in typical Middle East Solar cooling climate conditions. A centralized cooling station is supposed to distribute chilled water for a residential com- District cooling pound through a piping network. Two different solar cooling technologies are compared: two-stage lithium- Parabolic trough bromide absorption chiller (2sABS) driven by Parabolic Trough Collectors (PTCs) vs. single-stage lithium-bro- Absorption chiller mide absorption chiller (1sABS) fed by Evacuated Tube Collectors (ETCs). A computer code has been developed Thermal storage in Trnsys® (the transient simulation software developed by the University of Wisconsin) to simulate on hourly basis the annual operation of the solar cooling system, including building thermal load calculation, thermal losses in pipes and control strategy of the energy storage. A solar fraction of 70% was considered to size the solar field aperture area and the chiller capacity, within a multi-variable optimization process. An auxiliary com- pression chiller is supposed to cover the peak loads and to be used as backup unit. The two different solar cooling plants exhibit strongly different performance. For each plant configuration, the model determined the optimal size of every component leading to the primary cost minimization. -
Submission to the DCCAE's Consultation “Ireland's Draft
Submission to the DCCAE’s Consultation “Ireland’s Draft National Energy and Climate Plan (NECP) 2021-2030” Submission prepared by the Irish District Energy Association February 2019 www.districtenergy.ie [email protected] Submission to ‘Draft NECP’ Consultation from DCCAE: February 2019 Contents Contents ........................................................................................................................................................ 2 1 Introduction .......................................................................................................................................... 3 2 IrDEA welcomes the support for District Heating in the responses to the Initial NECP Consultation .. 3 3 The Potential for District Heating is much higher than proposed in the NECP .................................... 4 4 District Heating is a key enabler of Renewable Heat ............................................................................ 5 4.1 Excess Heat Should be Considered along with Renewable Heat as it also offsets carbon emitting fuels such as oil and gas ............................................................................................................................ 8 5 The Flexibility of District Heating Should be valued under Energy Security ......................................... 9 6 Increasing Renewable Heat will require stronger signals and/or support ......................................... 12 7 Bioenergy should be prioritised where it adds most value ............................................................... -
How Does a Recirculating Chiller Do Heating?
How does a Recirculating Chiller do Heating? Mitchell Howard, Technical Manager March 2019 © Applied Thermal Control 2019 What is this guide for? To explain how ATC’s chillers can heat as well as cool. • Heat of compression adds energy to refrigerant • Act of compression itself causes temperature to rise. • Electrical energy input to compressor enters refrigerant through conduction as refrigerant circulates. • Hot Gas Bypass (HGB) capacity control • Instead of allowing hot gaseous refrigerant to pass into the condenser to do conventional refrigeration, it is redirected into the evaporator via a discharge bypass valve (DBV or HGBV). 2 © Applied Thermal Control 2019 Reverse-Carnot Cycle Thermodynamic model used when chiller cools. 6 5 4 7 1. Compressor suction port draws refrigerant in. 2. Compression increases pressure and heat. 3. Sensible cooling begins at the condenser. 4. Sensible cooling completed; state change starts. 3 5. State change in condenser –constant temp and pressure 6. Latent cooling completed; further sensible cooling to point 7 ensures liquid supply. This is subcooling. 7. Expansion process begins at the inlet to TEV. 8 2 8. Expansion is achieved by reducing pressure through a Pressure tiny orifice. Low pressure and temperature seen at outlet. 9. Inlet to evaporator provided with refrigerant already going 9 1 through state change. 10. Boiling (evaporation) process continues in the evaporator. 11. Liquid cannot be compressed; additional sensible heating 10 11 applied before gaseous refrigerant can enter compressor. This is known as superheat. Heat Content (Enthalpy) (Energy per unit Mass) 3 © Applied Thermal Control 2019 Why does a compressor heat? Due to isentropic compression and electric motor inefficiency. -
A Little About Limits…
FOREST-Handbook, chapter 03-00 1 District heating – Introduction 03-00: Introduction to small-scale district heating… As a “small” district heating network, one would consider anything with a peak thermal power less than about 5-10 MW, but there is no strict limit. The fundamental idea with district heating is simple enough, as shown by the schematic below: Thus, the system consists basically of three serial circuits, a boiler circuit, a distribution circuit and a customer circuit. In practice, there will be two customer circuits – one for the tap water and one for the comfort heating system water. These will be manifest as two separate coils in the customer heat exchanger but for simplicity only one is included in the schematic. The main components and their roles The boiler-end heat exchanger Looking at the schematic above it is obvious that the district heating system contains two heat exchangers – one at the boiler end and one with the customer. From a purely theoretical point of view, it might seem wise to exclude the boiler-end heat exchanger and to use the boiler circuit water also for the distribution, but this is not recommended for two reasons: 1) The part in the system most exposed to and most vulnerable to leakages is the distribution network, which may well extent for several kilometres across the township. In case of a major leakage – and if the boiler water is also the circulating water – the boiler will be dry and may suffer severe damage. Hence, the heat exchanger protects the boiler. 2) For maximum efficiency in the system as a whole it is important that the return water in the distribution system is as cold as possible – preferably below 50 oC.