Proposed Reverse Osmosis (RO) Waterworks Facility And

Total Page:16

File Type:pdf, Size:1020Kb

Proposed Reverse Osmosis (RO) Waterworks Facility And Proposed Reverse Osmosis (RO) Q Why can’t H2GO negotiate better wholesale Q Can H2GO purchase and treat raw water from Waterworks Facility and Groundwater Supplies water rates with Brunswick County Public the Cape Fear River? Utilities? No. Lower Cape Fear Water & Sewer Authority has Frequently Asked Questions Wholesale water rates must be consistent for all previously informed H2GO that lack of capacity in wholesale water customers. The County has existing their existing raw water transmission system Q Is H2GO a private utility? wholesale water contracts that require the use of the prevents them from selling raw water allocations to No. H2GO is a governmental, public entity PPI method to set wholesale water rates. The H2GO. established by the State of North Carolina for the wholesale water contracts that contain that purpose of preserving and promoting the public provision expire in 2020 and until then, the County is Q Does Lower Cape Fear Water & Sewer Authority health and welfare. unable or unwilling to change to a cost-based rate have sufficient raw water capacities to supply setting method. their wholesale regional customers’ future raw Q Is H2GO governed by Leland or by Brunswick water needs? County? Q If Brunswick County Public Utilities set Not without an expansion of their raw water No. H2GO is a self-governing public entity with an wholesale rates based on an AWWA cost-based transmission system. LCFW&SA is planning a $66 elected, five member Board of Commissioners. Our operation and maintenance rate methodology, million, 14 mile long, 60” raw water transmission regional service area is generally northeast would it affect H2GO’s retail rates? pipe. Inter-local agreements for design of this Brunswick County and includes Leland, Belville, parts Brunswick County Public Utilities’ officials have project have just recently been executed, but no of Navassa, and customers located outside the limits stated that the difference in rates between the PPI capacity and project cost allocations have been of these incorporated Towns. and the AWWA rate methodology is within pennies. determined, and no timetable for construction of the However, if and when Brunswick County Public project has been announced. Q Where does H2GO get our water from? Utilities moves to an AWWA cost-based rate Brunswick County Public Utilities sells wholesale methodology, wholesale water rates could be Q Does Brunswick County Public Utilities have finished water to H2GO, Leland, Navassa, Northwest directly affected by Brunswick County Public Utilities’ sufficient treatment capacity to supply H2GO’s and about 10 other wholesale customers in southern capital improvement projects, increased debt future water needs? Brunswick County. service, expanded operations and maintenance, and Not without expanding their surface water treatment increased raw water costs charged by Lower Cape plant. Brunswick County Public Utilities has Q How does Brunswick County Public Utilities set Fear Water & Sewer Authority. considered a $30 million expansion of their surface wholesale rates to H2GO and other wholesale water treatment plant from 24 MGD to 36 MGD, but customers? Q What is AWWA? no timetable for the project has been announced. Wholesale water rates charged by Brunswick County AWWA is the American Water Works Association. Brunswick County Public Utilities’ plant expansion is Public Utilities are based on the Producers Price awwa.org also dependent upon the implementation of Index (PPI). The PPI has increased by more nearly LCFW&SA’s raw water transmission system 87% since 1985 and is projected to increase another Q Where does Brunswick County get their water improvements. 50% over the next 20 years. from? Brunswick County buys raw water from the Lower Q Why is H2GO looking to build and operate its Q Does the PPI for wholesale water rates affect Cape Fear Water & Sewer Authority (LCFW&SA), who own reverse osmosis water treatment facility? H2GO’s retail rates? owns this region’s permit to withdraw water from Primarily, to better manage water costs and rates for Yes. H2GO pays for every gallon of water purchased the Cape Fear River. Lower Cape Fear Water & our customers. For the past 5½ years, H2GO has from Brunswick County Public Utilities. If the PPI and Sewer Authority provides wholesale regional raw studied the comparative cost between building a wholesale water rates increase, as they have by water supplies to local governments and industry reverse osmosis water treatment facility and nearly 24% over the past 12 years, H2GO passes within a five-county service area comprised of continuing to purchase water from Brunswick County along those direct cost increases to our customers. Bladen, Brunswick, Columbus, New Hanover and Public Utilities. H2GO’s team of professional Pender Counties. planners, consulting engineers, hydrogeologists, and financial rate consultants has evaluated, analyzed, drought; and water quality degradation from the and developed detailed technical and financial effects of hurricanes. Q What backup water supplies to the reverse documentation necessary for H2GO’s staff and Board osmosis treatment facilities will be available to of Commissioners to determine that building a Q If our current water supplies from the Cape H2GO? reverse osmosis water treatment facility would be Fear River or from Brunswick County Public H2GO will maintain interconnections with Brunswick financially beneficial to its customers. The reverse Utilities were interrupted, how long could County Public Utilities – beneficial two-way osmosis water treatment facility will not only provide H2GO continue to provide water to its interconnections to improve water system resiliency a financial benefit to H2GO’s customers, but it will customers? for both entities. also meet the growing water needs of H2GO’s rapidly H2GO has less than a day’s average usage in storage. expanding customer base. Brunswick County Public Utilities could provide up to Q What would happen in the case of a drought? 1 million gallons per day via an interconnection The Lower Peedee and Black Creek aquifers are Q Why wouldn’t H2GO continue to buy wholesale agreement with Columbus County. H2GO’s current deep, confined aquifers. They are not susceptible to water from Brunswick County Public Utilities? average daily demand is about 1.7 million gallons per drought. The cost to buy wholesale water is now at a point day (MGD), and our maximum daily demand has where the annual wholesale water payments to exceeded 3.7 MGD. Q How many customers are in the H2GO service Brunswick County Public Utilities are greater than area? the annual cost to finance a new reverse osmosis Q Is H2GO proposing to build and operate a H2GO serves approximately 10,000 water customers water treatment facility. With H2GO’s growing user reverse osmosis water treatment facility just to and nearly 6,000 sewer customers. The historic base, increasing water demands, and an escalating secure an alternate water source? growth rate for our service area has been about 2.5% PPI (increasing wholesale water rates), H2GO’s No. The decision to move forward with the reverse annually. Last year, the customer base rose by more wholesale water payments to Brunswick County osmosis water treatment facility is primarily based than 6% and is forecast to trend at or greater than Public Utilities will continue to increase; and will on the cost of water and the ability to manage 3.7% for the next several years. H2GO’s customer soon exceed the total cost to finance and operate expenses for the benefit of our customers’ rates. base is projected to double within the next 25 years. the reverse osmosis water treatment facility. Having an alternate water source associated with our Analogy: Renting a house sometimes makes sense; own reverse osmosis water treatment facility will, Q How much water is used in the H2GO service but when the landlord increases the rent and those however, significantly improve water system area? rent payments get to a point that they exceed resiliency for our customers. Although cost of water H2GO’s average daily demand (ADD) for water is mortgage payments, insurance and taxes, it becomes is the driving force to implement this project, an about 1.7 million gallons per day (MGD). The good financial sense to buy the house. alternate water source has been a key consideration. maximum daily demand has exceeded 3.7 MGD. The average daily water demand in the H2GO service Q What is wrong with the water from the Cape Q What benefit does the plant hold for customers area is projected to reach 3.0 MGD by 2035, with Fear River? and the community? maximum daily demands at or above 6 MGD by The Cape Fear River does provide a suitable raw The plant will produce high quality finished water for 2035. water supply for treatment for potable water use; our customers. H2GO customers will not see any and Brunswick County Public Utilities does provide a water rate increases and the rates should remain at Q What is the capacity of the proposed reverse good quality finished water to H2GO and other or below current rates for the foreseeable future. osmosis water treatment facility? wholesale water customers. As with any surface The plant will also provide a backup water supply for The reverse osmosis water treatment facility will be water supplies, however, the river does have its other communities in cases of critical water shortage designed to produce up to 4.0 MGD of finished vulnerabilities. These vulnerabilities include future emergencies. Deep-well ground water supplies are water. The plant will be designed to accommodate supply allocations; susceptibility to chemical/toxic not vulnerable to surface contamination and other an expansion to 6.0 MGD and a build-out capacity of spills; 200+ wastewater dischargers upstream; hazards, improving system resiliency for H2GO 8.0 MGD. agricultural run-off; algae blooms; emerging customers.
Recommended publications
  • Water Treatment and Reverse Osmosis Systems
    Pure Aqua, Inc.® Water© 2012 TreatmentPure Aqua ,and Inc. ReverseAll Right sOsmosis Reserve dSystems. Worldwide Experience Superior Technology About the Company Pure Aqua is a company with a strong philosophy and drive to develop and apply solutions to the world’s water treatment challenges. We believe that both our technology and experience will help resolve the growing shortage of clean water worldwide. Capabilities and Expertise As an ISO 9001:2008 certified company with over a decade of experience, Pure Aqua has secured its position as a leading manufacturer of reverse osmosis systems worldwide. Goals and Motivations Our goal is to provide environmentally sustainable systems and equipment that produce high quality water. We provide packaged systems and technical support for water treatment plants, industrial wastewater reuse, and brackish and seawater reverse osmosis plants. Having strong working relationships with Thus, we ensure our technological our suppliers gives us the capability to contribution to water preservation by provide cost effective and competitive supplying the means and making it highly water and wastewater treatment systems accessible. for a wide range of applications. Seawater Reverse Osmosis Systems System Overview Designed to convert seawater to potable water, desalination systems use high quality reverse osmosis seawater membranes. The process separates dissolved salts by only allowing pure water to pass through the membrane fabric. System Capacities Pure Aqua desalination systems are designed to provide high
    [Show full text]
  • Circle Reverse Osmosis System
    CIRCLE REVERSE OSMOSIS SYSTEM KEY FEATURES Water Saving Technology – Patented technology eliminates backpressure The RC100 conforms to common in conventional RO systems making the Circle up to 10 times more NSF/ANSI 42, 53 and efficient than existing products. 58 for the reduction of Saves You Money – Conventional RO systems waste up to 24 gallons of Aesthetic Chlorine, Taste water per every 1 gallon of filtered water produced. The Circle only wastes and Odor, Cyst, VOCs, an average of 2.1 gallons of water per 1 gallon of filtered water produced, Fluoride, Pentavalent Arsenic, Barium, Radium 226/228, Cadmium, Hexavalent saving you water and money over the life of the product!. Chromium, Trivalent Chromium, Lead, RO Filter Auto Flushing – Significantly extends life of RO filter. Copper, Selenium and TDS as verified Chrome Faucet Included – With integrated LED filter change indicator. and substantiated by test data. The RC100 conforms to NSF/ANSI 372 for Space Saving Compact Design – Integrated rapid refill tank means more low lead compliance. space under the sink. SPECIFICATIONS Product Name H2O+ Circle Reverse Osmosis Water Filtration System Model / SKU RC100 Installation Undercounter Sediment Filter, Pre-Carbon Plus Filter, Post Carbon Block Filter (RF-20): 6 months Filters & Lifespan RO Membrane Filter (RF-40): 24 months Tank Capacity 6 Liters (refills fully in less than one hour) Dimensions 9.25” (W) x 16.5” (H) x 13.75” (D) Net weight 14.6 lbs Min/Max Operating Pressure 40 psi – 120 psi (275Kpa – 827Kpa) Min/Max Water Feed Temp 41º F – 95º F (5º C – 35º C) Faucet Flow Rate 0.26 – 0.37 gallons per minute (gpm) at incoming water pressure of 20–100 psi Rated Service Flow 0.07 gallons per minute (gpm) Warranty One Year Warranty PO Box 470085, San Francisco CA, 94147–0085 brondell.com 888-542-3355.
    [Show full text]
  • Refinery Wastewater Management Using Multiple Angle Oil-Water Separators
    REFINERY WASTEWATER MANAGEMENT USING MULTIPLE ANGLE OIL-WATER SEPARATORS Kirby S. Mohr, P.E. Mohr Separations Research, Inc. 1278 FM 407 Suite 109 Lewisville, TX 75077 Phone: 918-299-9290 Cell: 918-269-8710 John N. Veenstra, Ph.D., P.E., Oklahoma State University Dee Ann Sanders, Ph.D., P.E. Oklahoma State University A paper presented at the International Petroleum Environment Conference in Albuquerque, New Mexico, 1998 ABSTRACT In this work, an overview of oil-water separation, as used in the petroleum refining industries, is presented along with case studies. Discussions include: impact of solids, legal aspects, and differing types of systems currently in use, along with their advantages and disadvantages. Performance information on separators is presented with an emphasis on new multiple angle coalescing plate technology for refinery wastewater management. Several studies are presented including a large (20,000 US GPM flow rate) system recently installed at a major US refinery. The separator was constructed by converting two existing API separators into four separators, and adding multiple angle coalescing plates to increase throughput and efficiency. A year of operating experience with this system indicates good performance and few problems. Other examples provide information on separators installed in the United States and other countries. Keywords: Oil-water separator, multiple angle, coalescence, refinery, wastewater management, petroleum, coalescing plate technology BACKGROUND AND INTRODUCTION Oil has been refined for various uses for at least 1000 years. An Arab handbook written by Al-Razi, in approximately 865 A.D., describes distillation of “naft” (naphtha) for use in lamps and thus the beginning of oil refining (Forbes).
    [Show full text]
  • Reverse Osmosis As a Pretreatment of Ion Exchange Equipment at PSE
    Copyright Warning & Restrictions The copyright law of the United States (Title 17, United States Code) governs the making of photocopies or other reproductions of copyrighted material. Under certain conditions specified in the law, libraries and archives are authorized to furnish a photocopy or other reproduction. One of these specified conditions is that the photocopy or reproduction is not to be “used for any purpose other than private study, scholarship, or research.” If a, user makes a request for, or later uses, a photocopy or reproduction for purposes in excess of “fair use” that user may be liable for copyright infringement, This institution reserves the right to refuse to accept a copying order if, in its judgment, fulfillment of the order would involve violation of copyright law. Please Note: The author retains the copyright while the New Jersey Institute of Technology reserves the right to distribute this thesis or dissertation Printing note: If you do not wish to print this page, then select “Pages from: first page # to: last page #” on the print dialog screen The Van Houten library has removed some of the personal information and all signatures from the approval page and biographical sketches of theses and dissertations in order to protect the identity of NJIT graduates and faculty. ABSTRACT REVERSE OSMOSIS AS A PRETREATMENT FOR ION EXCHANGE AT PSE&G'S HUDSON GENERATING STATION by Steven Leon Public Service Electric and Gas Company's Hudson Generating Station has historically had problems providing sufficient high quality water for its two once through, supercritical design boilers. The station requires over 60 million gallons annually to compensate for system losses.
    [Show full text]
  • Selective Salt Recovery from Reverse Osmosis Concentrate Using Inter-Stage Ion Exchange Joshua E
    University of New Mexico UNM Digital Repository Civil Engineering ETDs Engineering ETDs 7-3-2012 Selective salt recovery from reverse osmosis concentrate using inter-stage ion exchange Joshua E. Goldman Follow this and additional works at: https://digitalrepository.unm.edu/ce_etds Recommended Citation Goldman, Joshua E.. "Selective salt recovery from reverse osmosis concentrate using inter-stage ion exchange." (2012). https://digitalrepository.unm.edu/ce_etds/8 This Dissertation is brought to you for free and open access by the Engineering ETDs at UNM Digital Repository. It has been accepted for inclusion in Civil Engineering ETDs by an authorized administrator of UNM Digital Repository. For more information, please contact [email protected]. Joshua E. Goldman Candidate CIVIL ENGINEERING Department This dissertation is approved, and it is acceptable in quality and form for publication: Approved by the Dissertation Committee: Dr. Kerry J. Howe , Chairperson Dr. Bruce M. Thomson Dr. Stephen E. Cabaniss Dr. Jerry Lowry i Selective Salt Recovery from Reverse Osmosis Concentrate Using Inter-stage Ion Exchange BY Joshua E. Goldman B.A., Anthropology, State University of New York at Stony Brook, 2000 M.S, Environmental Science, University of South Florida, 2007 DISSERTATION Submitted in Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy Engineering The University of New Mexico Albuquerque, New Mexico May, 2012 ii DEDICATION This dissertation is dedicated to the loving memory of my grandmother, Henriette Stein. iii ACKNOWLEDGMENTS This project was funded by the WateReuse Research Foundation. Resins were donated by ResinTech and Purolite. Francis Boodoo of ResinTech provided technical consultation for the pilot design.
    [Show full text]
  • Appendix A: Distillation and Reverse Osmosis Brine NOD, Phase I
    This document is part of Appendix A and includes Distillation and Reverse Osmosis Brine: Nature of Discharge for the “Phase I Final Rule and Technical Development Document of Uniform National Discharge Standards (UNDS),” published in April 1999. The reference number is EPA-842-R-99-001. Phase I Final Rule and Technical Development Document of Uniform National Discharge Standards (UNDS) Distillation and Reverse Osmosis Brine: Nature of Discharge April 1999 NATURE OF DISCHARGE REPORT Distillation and Reverse Osmosis Brine 1.0 INTRODUCTION The National Defense Authorization Act of 1996 amended Section 312 of the Federal Water Pollution Control Act (also known as the Clean Water Act (CWA)) to require that the Secretary of Defense and the Administrator of the Environmental Protection Agency (EPA) develop uniform national discharge standards (UNDS) for vessels of the Armed Forces for “...discharges, other than sewage, incidental to normal operation of a vessel of the Armed Forces, ...” [Section 312(n)(1)]. UNDS is being developed in three phases. The first phase (which this report supports), will determine which discharges will be required to be controlled by marine pollution control devices (MPCDs)—either equipment or management practices. The second phase will develop MPCD performance standards. The final phase will determine the design, construction, installation, and use of MPCDs. A nature of discharge (NOD) report has been prepared for each of the discharges that has been identified as a candidate for regulation under UNDS. The NOD reports were developed based on information obtained from the technical community within the Navy and other branches of the Armed Forces with vessels potentially subject to UNDS, from information available in existing technical reports and documentation, and, when required, from data obtained from discharge samples that were collected under the UNDS program.
    [Show full text]
  • Reverse Osmosis Brochure
    REVERSE OSMOSIS RO Storage Tanks High Purity Water Storage REVERSE OSMOSIS Amtrol invented the pre-pressurized water storage tank over 50 years ago and they are still considered the standard of the industry. These tanks feature a polypropylene liner and butyl diaphragm to prevent water from making contact with the metal tank for cleaner, fresher, better tasting water. All Amtrol RO tanks are manufactured in the USA at our ISO 9001:2008 registered facilities. REVERSE OSMOSIS Tanks • Provide water storage in reverse osmosis water systems. Polypropylene liner and butyl rubber diaphragm • Meet the most demanding specifications for are locked together with potable water. Amtrol’s unique hoop ring • Reliable diaphragm vs. bladder design. and groove design. • Individually tested for safety. ® Durable steel tank for • Available with Pro-Access stainless steel extra-long life. system connection. Typical Installation Cold Hot Drain Line Water Water Line Line Recirculation Line RO Water Membrane Feed Reverse Osmosis Water Storage Tank Pre Post Filter Filter Specifications and Tank Selection A Under Sink Models System Tank A B Tank Shipping Model Connection1 Tank Stand Model Volume Diameter Height Precharge Weight Number NPTM Color Type (Gallons) (Inches) (Inches) (psi) (lbs.) B (Inches) RO-2 140-32 2.0 8 13 ¼ Blue 5 Plastic 5 RO-2 140-653 2.0 8 13 ¼ Blue 20 Plastic 5 Standard RO-3 140S723 3.2 9 15 ¼ White 5 Plastic 7 RO-3 140S725 3.2 9 14 ¼ White 5 3 Bumps 7 A RO-4 141S343 4.4 11 15 ¼ Blue 5 Plastic 9 RO-4 141S344 4.4 11 15 ¼ White 5 Plastic 9 RO-4 141S351 4.4 11 15 ¼ White 5 3 Bumps/Plastic 9 B RO-4 141S352 4.4 11 15 ¼ Blue 5 3 Bumps/Plastic 9 RO-10 143-132 10.0 15 18 ¾ Blue 5 Plastic 20 1 Stainless Steel System Connection.
    [Show full text]
  • 21 Reverse Osmosis Treatment of PDWS 03-09
    PRIVATE DRINKING WATER IN CONNECTICUT Publication Date: March 2009 Publication No. 21: Reverse Osmosis Treatment of Private Drinking Water Systems Effective Against: inorganic contaminants such as: dissolved salts of sodium, dissolved (ferrous) iron, nitrate, lead, fluoride, sulfate, potassium, manganese, aluminum, silica, chloride, total dissolved solids, chromium, and orthophosphate. Also effective in removing some detergents, some taste, color and odor-producing chemicals, certain organic contaminants, uranium, and some pesticides. Not Effective Against: dissolved gases, most volatile and semi-volatile organic contaminants including some pesticides and solvents. Alone, reverse osmosis (RO) units are not recommended for treatment of bacteria and other microscopic organisms. How Reverse Osmosis Works A complete reverse osmosis system consists of a RO module, a storage tank, and a separate faucet. The module contains a semi-permeable membrane that allows water to selectively pass through and collect in the storage tank. The contaminants being treated by the RO unit are rejected and then washed off the membrane into a waste stream. It is not practical to treat all water entering a home with an RO system because about 75 percent of the water introduced is wasted. Thus, four gallons of raw water into the system produce about one gallon of treated water. This treated water comes out much slower than water from a regular tap, so a tank is used to store the treated water. The treated water is often used only for drinking and cooking. Each manufacturer’s RO units differ, but the time needed to produce one gallon of water ranges from 2-78 hours. The volume of wastewater produced by RO systems varies by make and model.
    [Show full text]
  • Seawater Desalination for Agriculture by Integrated Forward and Reverse Osmosis: Improved Product Water Quality for Potentially Less Energy
    Journal of Membrane Science 415–416 (2012) 1–8 Contents lists available at SciVerse ScienceDirect Journal of Membrane Science journal homepage: www.elsevier.com/locate/memsci Perspective Seawater desalination for agriculture by integrated forward and reverse osmosis: Improved product water quality for potentially less energy Devin L. Shaffer a, Ngai Yin Yip a, Jack Gilron b,1, Menachem Elimelech a,n a Department of Chemical and Environmental Engineering, Yale University, P.O. Box 208286, New Haven, CT 06520-8286, USA b Zuckerberg Institute for Water Research, Ben-Gurion University of the Negev, Sde Boker 84990, Israel article info abstract Article history: Seawater desalination for agricultural irrigation will be an important contributor to satisfying growing Received 21 March 2012 water demands in water scarce regions. Irrigated agriculture for food production drives global water Received in revised form demands, which are expected to increase while available supplies are further diminished. Implementa- 6 May 2012 tion of reverse osmosis, the current leading technology for seawater desalination, has been limited in Accepted 7 May 2012 part because of high costs and energy consumption. Because of stringent boron and chloride standards Available online 15 May 2012 for agricultural irrigation water, desalination for agriculture is more energy intensive than desalination Keywords: for potable use, and additional post-treatment, such as a second pass reverse osmosis process, is Seawater desalination required. In this perspective, we introduce the concept of an integrated forward osmosis and reverse Forward osmosis osmosis process for seawater desalination. Process modeling results indicate that the integrated Integrated process process can achieve boron and chloride water quality requirements for agricultural irrigation while Boron Agriculture consuming less energy than a conventional two-pass reverse osmosis process.
    [Show full text]
  • Treatment of Municipal Wastewater Reverse Osmosis Concentrate Using Biological Activated Carbon Based Processes
    Treatment of Municipal Wastewater Reverse Osmosis Concentrate using Biological Activated Carbon based Processes A thesis submitted in fulfilment of the requirement for the degree of Doctor of Philosophy (PhD) Shovana Pradhan Master of Engineering (Civil/Environmental), Asian Institute of Technology (AIT), Thailand School of Civil, Environmental and Chemical Engineering College of Science, Engineering and Health RMIT University, Melbourne, Australia November, 2016 Declaration I hereby declare that: • the work presented in this thesis is my own work except where due acknowledgement has been made; • the work has not been submitted previously, in whole or in part, to qualify for any other academic award; • the content of the thesis is the result of work which has been carried out since the official commencement date of the approved research program. .............................. (Shovana Pradhan) ........../........../.......... 1 Acknowledgements I would like to express my sincere thanks and deep gratitude to my senior supervisor, Dr. Linhua Fan who has kindly given me the opportunity to pursue PhD study under his constant guidance. This thesis would have not been possible without his continuous encouragement, constructive feedback, invaluable advice and scientific inputs. Secondly, I would like to thank Prof. Felicity Roddick as my second supervisor, for her generous support, insightful counsel throughout my study period. She has been extremely motivating, encouraging and positive to my research work. The timely and constructive feedback from my supervisors helped me to improve the quality of my work, as well as professional development during my PhD work. I am grateful for providing scholarship to pursue my PhD by RMIT University. I would like to thank Prof.
    [Show full text]
  • Oily Wastewater Treatment: Removal of Dissolved Organic Components by Forward Osmosis Rajab M
    University of Wollongong Research Online University of Wollongong Thesis Collection University of Wollongong Thesis Collections 2012 Oily wastewater treatment: removal of dissolved organic components by forward osmosis Rajab M. Abousnina University of Wollongong Recommended Citation Abousnina, Rajab M., Oily wastewater treatment: removal of dissolved organic components by forward osmosis, Master of Engineering - Research thesis, School of Civil, Mining and Environmental Engineering, University of Wollongong, 2012. http://ro.uow.edu.au/theses/3750 Research Online is the open access institutional repository for the University of Wollongong. For further information contact the UOW Library: [email protected] School of Civil, Mining, and Environmental Engineering Oily Wastewater Treatment: Removal of Dissolved Organic Components by Forward Osmosis Rajab M. Abousnina This thesis is presented as part of the requirements for the award of the Degree of Master of Engineering Research University of Wollongong October 2012 Abstract Produced water is water brought to the surface with crude oil or natural gas; it is the largest waste stream by volume associated with the production of oil and gas. Some crude oil and traces of organic compounds, particularly organic acids, are known to occur in produced water. Although the current international standard limits the amount of dissolved oil in produced water to less than 30 mg/L prior to environmental discharge, no regulations exist for other dissolved organic constituents. This is mostly because of the lack of low cost, high efficiency technologies capable of removing dissolved organic constituents from produced water. This work investigated the removal of dissolved organics from produced water by the forward osmosis (FO) process, with a particular focus on Libya.
    [Show full text]
  • Large-Diameter Reverse Osmosis Facility Redefines Water Reuse
    Plant Profile Large-Diameter Reverse Osmosis Facility Redefines Water Reuse A vision for the future was realized when the city of Scottsdale, Ariz., began operating the Scottsdale Water Campus in 1999 to augment the city’s water supply and reclaim water. The facility remains at the forefront of water reuse. BY KEVIN ALEXANDER, ART NUNEZ, BINGA TALABI, DAVE FABER, AND GERRY FILTEAU N THE EARLY 1990s, Scottsdale, Ariz., ■ tertiary filtration with cloth-media filtrate production capacity to increase from managers and planners examined filters. 16 mgd to 23.6 mgd within the existing future growth and water needs. ■ chloramination for primary and resid- process building. The RO system capacity They envisioned a water resources ual disinfection. increased from 13.8 mgd to 20 mgd of per- Imanagement facility that would reclaim ■ MF and RO followed by lime meate production using a large-diameter the city’s sewage, allow for aquifer stabilization. RO system to save space. Additionally, UV storage and recovery, and augment the Product water from the plant has been treatment was added to the building that city’s limited groundwater and surface recharged to the local aquifer, achieving a housed the expanded RO system. water sources. The facility—the Water higher quality than required by state per- The Scottsdale Water Campus pio- Campus—was strategically designed mitting authorities. neered the use of the latest RO technol- to allow the city to reclaim water that Historically, area golf courses received ogy. The facility is a great place to see previously had little chance of being tertiary treated effluent, but rising salin- the history of RO technology and how reused as it was discharged to another ity in the reclaimed water caused turf all of the technology is still successfully regional wastewater treatment plant.
    [Show full text]