List of Type Approved Signalling Equipment RIC NSW - Signalling Equipment Approvals

The signalling equipment listed below, formerly approved by Rail Corporation and subsequently by RailCorp may be used in the same configuration and use on the ARTC network, that it has been used on the NSW network. For installation in other configurations or functions that are different than previous usage, an application for Engineering Waiver or Equipment Type Approval must be submitted to the ARTC Manager Standards & Systems. The equipment shall be used in accordance with the relevant ARTC Standards and Instructions for the respective network area.

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *95/051 systems WB&S WB&S 'Westvaco' CBI Not currently approved. *95/122 Power supply, detectors-earth MRD Earth leakage detectors - MRD Interim leakage *96/0301 Cables, cable markers Critchley Cable marker sleeves - Critchley type HS032 Full 14.3.96 *96/0302 Cables, cable markers Weidmuller Cable marker sleeves - Weidmuller /QED 'Partex', Full 14.3.96 type PA01 and PA02 *96/0401 Cables, Route material, IPS Continuous flexible conduit - IPS PE80 MDPE, Interim 24.4.96 conduit Installed by ploughing methods *96/0501 circuit, components Westinghouse Westinghouse FS2600 complete Interim 1.5.96 *96/0502 Relays, full size plug in Westinghouse Westinghouse 'SAFEFLASH' flasher Interim 1.5.96 *96/0503 Signals GEC GEC Route Indicator Interim 17.5.96 *96/0504 Power supply, detectors-earth Leonard Earth Leakage detector - LE51 - Leonard Electronics Interim 24.5.96 leakage Electronics Full 30/9/98 *96/0601 Motor Generators Parker Hannifin Parker Hannifin 125 mm latched Air Motor Interim 06/06/96 Full 27/09/96 *96/0703 Cables, cable markers Brady Cable Markers - Brady 'Duramark' & 'Pertmasleeve' Full 03/07/1996 *96/0717 Cables, bonding Olex Cables-Track Connection & Traction return Bonding – Interim 17/07/1996 Flexolex Cables supplied by Olex Cables Ltd (file:967Flxol)

*96/0718 Cables, jointing materials Erico Traction Bonds & exo-thermic welding material supplied by Full 17/07/1996 Erico Products Australia Ltd (items as per Schedule-1, file:967Erico)

*96/0719 Power supply, emergency Exectronics Pty Emergency Change-Over Contactor panels & FULL change-over Ltd Lightning/Surge protection panels supplied by Exectronics Pty Ltd *96/0901 Pneumatic ALPHA ALFAGMMA T290 AS 2660 Class B FRAS Air Hose Full 16/09/1996 INDUSTRIAL (Halogen Free) supplied by ALPHA INDUSTRIAL HOSE HOSE P/L P/L *96/0902 Cables, cable markers James Hardie Polythene Buried Cable Route Cover Strip manufactured Full 16/09/1996 by James Hardie Pipelines P/L

*96/1001 Cables,Terminals-rail Entrelec Entrelec Terminal M6/8 STP Cat No 115.277.20 Full 17/10/1997 mounted *96/1002 Cables,Terminals-rail Entrelec Entrelec Terminal M6/8 ST1 Cat No 115.237.10 Limited 17/10/1997 mounted (NV Circuits only) *96/1003 Cables,Terminals-rail Entrelec Entrelec Terminal M4/6 Cat No 115.116.07 Full 17/10/1997 mounted *96/1004 Cables,Terminals-rail Entrelec Entrelec Terminal M10/10 Cat No 115.120.17 Full 17/10/1997 mounted

1 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/1005 Cables,Terminals-rail Entrelec Entrelec Terminal M35/16 Cat No 115.124.07 Full 17/10/1997 mounted *96/1006 Cables,Terminals-rail Entrelec Entrelec Terminal M70/22.1 Cat No 115 216 13 Full 17/10/1997 mounted *96/1007 Cables,Terminals-rail Entrelec Entrelec Terminal Fuse MB10/12.SF1 Cat No 111.035.05 Full Fuses to 6.3A 17/10/1997 mounted *96/1008 Cables,Terminals-rail Entrelec Entrelec Terminal Fuse M10/16 SF Cat No 115.377.24 Full Fuses to 16A 17/10/1997 mounted *96/1009 Cables,Terminals-rail Entrelec Entrelec Terminal Fuse MB25/30 SF Cat No 116.305.26 Full Fuses to 63A 17/10/1997 mounted *96/1010 Cables,Terminals-rail Entrelec Entrelec Terminal M6/8 Cat No115.118.11 Full 17/10/1997 mounted *96/1011 Cables,Terminals-rail Entrelec Entrelec Terminal M10/16 SN1 Cat No 115.376.23 Full 17/10/1997 mounted *96/1012 Cables,Terminals-rail Entrelec Entrelec Terminal Power M35/26 EE Cat No 115.151.12 Full 17/10/1997 mounted *96/1013 Cables,Terminals-rail Entrelec Entrelec Terminal Power M150/35 EE Cat No 115.156.17 Full 17/10/1997 mounted *96/1014 Cables,Terminals-rail Entrelec Entrelec Terminal M6/8 SB Cat No 115.436.00 Full (NV Circuits) 17/10/1996 mounted Limited (Specific case by case approval for vital circuits) *96/405 Level crossing equipment Western railway Western Railroad Supply Co Type B Boom mechanism Not for new Supply purchases *96/406 Level crossing equipment Western railway Western Railroad Supply Co Type D Boom mechanism Not for new Supply purchases *96/p1 Relays, vital-miniature plug-in, WB&S Plug-in Relays, All items listed in Spec 1056, Prior to line WB&S, 'Q' type relays and bases 1/6/1996 *96/p10 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 211 BRB 960 Prior to line 50VDC, 2x4F4B (DC Neutral Twin Relay), 1/6/1996 WB&S,QNN1 *96/p100 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations 32V AC, 3PDT, Potter & Brumfield 1/6/1996 KRPA-90839, listed in Spec 432 *96/p101 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 32 V AC, 3PDT,Idec Izumi RR3P-U, 1/6/1996 listed in Spec 432 *96/p102 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations 48 V AC, 3PDT, Potter & Brumfield 1/6/1996 KRPA-90840, listed in Spec 432 *96/p103 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 48 V AC, 3PDT,Idec Izumi RR3P-U, 1/6/1996 listed in Spec 432 *96/p104 Relays, non-vital Fuji General Purpose relays with octal and 11-pin Approved Prior to teminations 120 V AC, SRA ID 06600506, 3PDT, 1/6/1996 Fuji HH23PWT, listed in Spec 432 *96/p105 Relays, non-vital Omron General Purpose relays with octal and 11-pin Approved Prior to teminations 120 V AC, SRA ID 06600506,3PDT, 1/6/1996 Omron MK3P-I, listed in Spec 432 *96/p106 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations 120 V AC, SRA ID 06600506,3PDT, 1/6/1996 Potter & Brumfield KRPA-90841, listed in Spec 432

2 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p107 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 120 V AC, SRA ID 06600506,3PDT, 1/6/1996 Idec Izumi RR3P-U, listed in Spec 432 *96/p108 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations 240 VAC, 3PDT, Potter & Brumfield 1/6/1996 KRPA-90842, listed in Spec 432 *96/p109 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 240 V AC, 3PDT,Idec Izumi RR3P-U, 1/6/1996 listed in Spec 432 *96/p11 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 211 BRB 960 Prior to line 50VDC, 2x4F4B ,WB&S,QNN1 base 1/6/1996 *96/p110 Relays, non-vital Omron General Purpose relays base, 8-pin, SRA ID Approved Prior to 06600118, Omron PF-083A, listed in Spec 432 1/6/1996 *96/p111 Relays, non-vital Potter & General Purpose relays base, 8-pin, SRA ID Approved Prior to Brumfield 06600118, Potter & Brumfield PXB 27E891, 1/6/1996 listed in Spec 432 *96/p112 Relays, non-vital Idec Izumi General Purpose relays base, 8-pin, SRA ID Approved Prior to 06600118, Idec Izumi SR2P-05C, listed in Spec 432 1/6/1996 *96/p113 Relays, non-vital Omron General Purpose relays base, 11-pin, SRA ID Approved Prior to 06600076, Omron PF-113A, listed in Spec 432 1/6/1996 *96/p114 Relays, non-vital Potter & General Purpose relays base, 11-pin, SRA ID Approved Prior to Brumfield 06600076,Potter & Brumfield (unsuitable-too wide), 1/6/1996 listed in Spec 432 *96/p115 Relays, non-vital Idec Izumi General Purpose relays base, 11-pin, SRA ID Approved Prior to 06600076, Idec Izumi SR3P-05C, listed in Spec 432 1/6/1996 *96/p116 Relays, non-vital NAIS Cradle Relay, 24V. DC K4EB-24V-1 or equivalent. Approved Prior to 1/6/1996 *96/p117 Relays, non-vital NAIS Non-vital Cradle Relay, 48V. DC K4EB-48V-1 or Approved Prior to equivalent. 1/6/1996 *96/p12 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code023 BRB 931 Prior to line 50VDC 12F4B (DC Neutral AC Immune), 1/6/1996 WB&S,QNA1 *96/p120 Wire Olex 7/0.40mm internal wire for safety application as per Spec. SC 11111000SP. *96/p121 Level crossing equipment Weatern Cullen Western Cullen Type 3593 Boom mechanism FULL *96/p122 Level Crossing equipment Westinghouse Westinghouse Crossing 200mm LED light units RG4- Issue with clear RTFB25B48V11 versus Red lense. *96/p123 Relays, non-vital Releco Filament changeover relay 1.3-1.5V Approved Prior to AC/DC BRB Spec 832 1/6/1996 *96/p124 Interlocking systems WB&S Computer-based interlocking,WB&S, FULL Prior to BRB SSI Mk2,Suitable for high traffic areas 1/6/1996 *96/p125 Interlocking systems GEC-A Computer-based interlocking,GEC-A, Prior to BRB SSI Mk2,Suitable for high traffic areas 1/6/1996 *96/p126 Interlocking systems WB&S Computer-based interlocking,WB&S, FULL Prior to Westrace, 1/6/1996 *96/p127 Interlocking systems US&S Computer-based interlocking,US&S, Restricted Prior to Microlok, For 1/6/1996 light/medium traffic areas only *96/p128 Cables, Jointing materials Raychem Heat-shrink kits and materials as listed Prior to in Specification 1062,Raychem,XAGA 1/6/1996 *96/p129 Cables, Jointing materials Walter Rose Heat-shrink kits and materials as listed Prior to in Specification 1062,Walter Rose 1/6/1996 *96/p13 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 023 BRB 931 Prior to line 50VDC 12F4B ,WB&S,QNA1 base 1/6/1996

3 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p131 Cables,Terminals-rail Kilppon Terminals for general signalling applications, Prior to mounted All items listed in Spec 1065,Klippon,full range 1/6/1996 *96/p132 Cables,Terminals-rail Phoenix Terminals for general signalling applications, Prior to mounted All items listed in Spec 1065,Phoenix,limited range 1/6/1996 *96/p133 Cables,Terminals-rail Utilux Terminals for general signalling applications, Prior to mounted All items listed in Spec 1065,Utilux,limited range 1/6/1996 *96/p134 Cables,Terminals-rail Wago Terminals for general signalling applications, Prior to mounted All items listed in Spec 1065,Wago,limited range 1/6/1996 *96/p135 Cables,Terminals-rail Utilux Disconnect link,Utilux ,equivalent to SAKC1 Type approval Prior to mounted withdrawn 1/6/1996 *96/p136 Cables,Terminals-rail Phoenix Terminals for non-vital systems,Items listed in Prior to mounted Spec 1030,Phoenix,limited range 1/6/1996 *96/p137 Cables,Terminals-rail Wago Terminals for non-vital systems,Items listed in Prior to mounted Spec 1030,Wago,limited range 1/6/1996 *96/p138 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type AKZ4 ,Cat No Approved, Listed Prior to mounted 29432 Rail TS,May not be used for terminating in Spec 1066 1/6/1996 external cables *96/p139 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK2.5 ,Cat Approved, Listed Prior to mounted No 27962 Rail TS32,May not be used for terminating in Spec 1067 1/6/1996 external cables *96/p14 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 024 BRB 931 Prior to line 50VDC, 8F8B (DC Neutral AC Immune), 1/6/1996 WB&S,QNA1 *96/p140 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK2.5/35, Approved, Listed Prior to mounted Cat No 38046,Rail TS35,May not be used for in Spec 1068 1/6/1996 terminating external cables *96/p141 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK4, Cat No Approved, Listed Prior to mounted 12832,Rail TS32,General purpose. in Spec 1069 1/6/1996 *96/p142 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK4/35, Cat Approved, Listed Prior to mounted No 44366,Rail TS35,General purpose in Spec 1070 1/6/1996 *96/p143 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK6N, Cat Approved, Listed Prior to mounted No 19322,Rail TS32,General purpose in Spec 1071 1/6/1996 *96/p144 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK6/35, Cat Approved, Listed Prior to mounted No 38056,Rail TS35,General purpose in Spec 1072 1/6/1996 *96/p145 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK10, Cat Approved, Listed Prior to mounted No 11002,Rail TS32,General purpose in Spec 1073 1/6/1996 *96/p146 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK10/35, Approved, Listed Prior to mounted Cat No 44376,Rail TS35,General purpose in Spec 1074 1/6/1996 *96/p147 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK35N, Approved, Listed Prior to mounted Cat No 55062,Rail TS32,General purpose in Spec 1075 1/6/1996 *96/p148 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAK35N/35, Approved, Listed Prior to mounted Cat No 60826,Rail TS35,General purpose in Spec 1076 1/6/1996 *96/p149 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAKG32, Cat Approved, Listed Prior to mounted No 17032,Rail TS32,Stud type terminal M6 stud in Spec 1077 1/6/1996 *96/p15 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 024 BRB 931 Prior to line 50VDC 8F8B ,WB&S,QNA1 base 1/6/1996 *96/p150 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type SAKG32/35, Approved, Listed Prior to mounted Cat No 63732,Rail TS35,Stud type terminal M6 stud in Spec 1078 1/6/1996 *96/p151 Cables,Terminals-rail Kilppon Feed Through Terminal Klippon Type DK4, Cat No Approved, Listed Prior to mounted 37116,Rail TS35,4-way terminal. May not be used in Spec 1079 1/6/1996 for terminating external cables *96/p152 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.279-101 , Approved, Listed Prior to mounted 279-104,Rail TS35,Non-vital only. in Spec 1080 1/6/1996

4 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p153 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.279-102 , Approved, Listed Prior to mounted 279-105,Rail TS32,Non-vital only in Spec 1081 1/6/1996 *96/p154 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.280-101 , Approved, Listed Prior to mounted 280-104,Rail TS35,May not be used to terminate in Spec 1082 1/6/1996 external cables. *96/p155 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.280-102 , Approved, Listed Prior to mounted 280-105,Rail TS32,May not be used to terminate in Spec 1083 1/6/1996 external cables. *96/p156 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.281-101 , Approved, Listed Prior to mounted 281-104,Rail TS35,General Purpose. in Spec 1084 1/6/1996 *96/p157 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.281-102 , Approved, Listed Prior to mounted 281-105,Rail TS32,General Purpose. in Spec 1085 1/6/1996 *96/p158 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.282-101 , Approved, Listed Prior to mounted 282-104,Rail TS35,General Purpose. in Spec 1086 1/6/1996 *96/p159 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.282-102 , Approved, Listed Prior to mounted 282-105,Rail TS32,General Purpose. in Spec 1087 1/6/1996 *96/p16 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 209 BRB Prior to line 966F6 50VDC, 2x6F2B (AC Immune), 1/6/1996 WB&S,QNNA1 *96/p160 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.284-101 , Approved, Listed Prior to mounted 284-104,Rail TS35,General Purpose. in Spec 1088 1/6/1996 *96/p161 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.284-102 , Approved, Listed Prior to mounted 284-105,Rail TS32,General Purpose. in Spec 1089 1/6/1996 *96/p162 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.283-101 , Approved, Listed Prior to mounted 283-104,Rail TS32,General Purpose. in Spec 1090 1/6/1996 *96/p163 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.283-102 , Approved, Listed Prior to mounted 283-105,Rail TS32,General Purpose. in Spec 1091 1/6/1996 *96/p164 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.280-647 , Approved, Listed Prior to mounted 280-657,Rail TS32,4-way terminal. May not be used in Spec 1092 1/6/1996 to terminate external cable *96/p165 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.280-646 , Approved, Listed Prior to mounted 280-656,Rail TS35,4-way terminal. May not be used in Spec 1093 1/6/1996 to terminate external cable *96/p166 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.280-641 , Approved, Listed Prior to mounted 280-651,Rail TS35,3-way terminal. May not be used in Spec 1094 1/6/1996 to terminate external cable *96/p167 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.280-642 , Approved, Listed Prior to mounted 280-652,Rail TS32,3-way terminal. May not be used in Spec 1095 1/6/1996 to terminate external cable *96/p168 Cables,Terminals-rail Wago Feed Through Terminal Wago Cat No.281-631 , Approved, Listed Prior to mounted 280-651,Rail TS35,3-way terminal block. in Spec 1096 1/6/1996 *96/p169 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type UK2.5,Cat No Approved, Listed Prior to mounted 30 01 01 9,Rail TS32/35,May not be used to in Spec 1097 1/6/1996 terminate external cables *96/p17 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 209 BRB 966F6 Prior to line 50VDC, 2x6F2B,WB&S,QNNA1 base 1/6/1996 *96/p170 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type K2.5,Cat No Approved, Listed Prior to mounted 13 01 07 0, 13 01 01 2,Rail TS32,May not be used in Spec 1098 1/6/1996 to terminate external cables *96/p171 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type UK4,Cat No Approved, Listed Prior to mounted 30 03 01 7,Rail TS32/35,General purpose in Spec 1099 1/6/1996 *96/p172 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type K4,Cat No Approved, Listed Prior to mounted 13 02 07 9,13 02 01 1,Rail TS32,General purpose in Spec 1100 1/6/1996

5 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p173 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type UK10,Cat No Approved, Listed Prior to mounted 30 05 01 5,Rail TS32/35,General purpose in Spec 1101 1/6/1996 *96/p174 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type K10,Cat No Approved, Listed Prior to mounted 13 03 08 7,13 03 01 0,Rail TS32,General purpose in Spec 1102 1/6/1996 *96/p175 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type UK16,Cat No Approved, Listed Prior to mounted 30 06 01 4,Rail TS32/35,General purpose in Spec 1103 1/6/1996 *96/p176 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type UK16N,Cat Approved, Listed Prior to mounted No 30 06 04 3,Rail TS32/35,General purpose in Spec 1104 1/6/1996 *96/p177 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type K16,Cat No Approved, Listed Prior to mounted 13 04 07 7, 13 04 01 9,Rail TS32,General purpose in Spec 1105 1/6/1996 *96/p178 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type UK25,Cat No Approved, Listed Prior to mounted 30 07 01 3,Rail TS32/35,General purpose in Spec 1106 1/6/1996 *96/p179 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type K25,Cat No Approved, Listed Prior to mounted 1305076,13 05 01 8,Rail TS32,General purpose in Spec 1107 1/6/1996 *96/p18 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code xxx BRB Prior to line 966F7 120VAC, 12F4B (AC Neutral Line 1/6/1996 Relay for SSI direct interface),WB&S,QNHX1 *96/p180 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type UK35,Cat No Approved, Listed Prior to mounted 30 08 01 2,Rail TS32/35,General purpose in Spec 1108 1/6/1996 *96/p181 Cables,Terminals-rail Phoenix Feed Through Terminal Phoenix Type K35,Cat No Approved, Listed Prior to mounted 13 06 07 5, 13 06 01 7,RailTS32,General purpose in Spec 1109 1/6/1996 *96/p182 Cables,Terminals-rail Entrelec Feed Through Terminal Entrelec Type M4/6,Cat No Approved, Listed Prior to mounted 115.116.07,Rail TS32/35,General purpose in Spec 1110 1/6/1996 *96/p183 Cables,Terminals-rail Entrelec Feed Through Terminal Entrelec Type M10/10,Cat Approved, Listed Prior to mounted No 115.120.17,Rail TS32/35,General purpose in Spec 1111 1/6/1996 *96/p184 Cables,Terminals-rail Entrelec Feed Through Terminal Entrelec Type M35/16,Cat Approved, Listed Prior to mounted No 115.124.07,Rail TS32/35,General purpose in Spec 1112 1/6/1996 (Not suitable for lip blade lugs) *96/p185 Cables,Terminals-rail Entrelec Feed Through Terminal Entrelec Type M70/22.1, Approved, Listed Prior to mounted Cat No 115.216.13,Rail TS32/35,General purpose in Spec 1113 1/6/1996 (Not suitable for lip blade lugs) *96/p186 Cables,Terminals-rail Entrelec Feed Through Terminal Entrelec Type M6/8,Cat No Approved, Listed Prior to mounted 115.118.11,Rail TS32/35,General purpose in Spec 1114 1/6/1996 *96/p187 Cables,Terminals-rail Entrelec Feed Through Terminal Entrelec Type DR4/6N,Cat Approved, Listed Prior to mounted No 110 491.17,Rail TS,May not be used for terminating in Spec 1115 1/6/1996 external cables *96/p188 Cables,Terminals-rail Entrelec Feed Through Terminal Entrelec Type DR4/6N,Cat Approved, Listed Prior to mounted No 120 491 11,Rail TS,May not be used for in Spec 1116 1/6/1996 terminating external cables *96/p189 Cables,Terminals-rail Kilppon Klippon Heavy Duty Feed Through Terminal SAK70, Approved, Listed Prior to mounted Cat No 34082,Rail TS32,Minimum conductor 16 mm² solid, in Spec 1117 1/6/1996 25 mm² stranded *96/p19 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code xxx BRB 966F7 Prior to line 120VAC, 12F4B,WB&S,QNHX1 base 1/6/1996 *96/p190 Cables,Terminals-rail Kilppon Klippon Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted SAKG40,Cat No 17042,Rail TS32,Stud type in Spec 1118 1/6/1996 terminal 10 mm stud *96/p191 Cables,Terminals-rail Kilppon Klippon Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted SAKG46,Cat No 17062,Rail TS32,Stud type in Spec 1119 1/6/1996 terminal 12 mm stud *96/p192 Cables,Terminals-rail Phoenix Phoenix Heavy Duty Feed Through Terminal UKH95 Approved, Listed Prior to mounted Cat No 30 10 01 3,Rail TS32/35,Minimum in Spec 1120 1/6/1996 conductor 25 mm²

6 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p193 Cables,Terminals-rail Phoenix Phoenix Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted UKH150,Cat No 30 10 11 0,Rail TS32/35, in Spec 1121 1/6/1996 Minimum conductor 35 mm² *96/p194 Cables,Terminals-rail Phoenix Phoenix Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted UKH240,Cat No 30 10 21 7,Rail TS32/35, in Spec 1122 1/6/1996 Minimum conductor 95 mm² *96/p195 Cables,Terminals-rail Phoenix Phoenix Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted UHV25M8/M8,Cat No 21 30 20 8,Rail TS32/35, in Spec 1123 1/6/1996 Stud type terminal 8 mm stud *96/p196 Cables,Terminals-rail Phoenix Phoenix Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted UHV50M10/M10,Cat No 21 30 21 1,Rail TS32/35, in Spec 1124 1/6/1996 Stud type terminal 10 mm stud *96/p197 Cables,Terminals-rail Phoenix Phoenix Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted UHV95M12/M12,Cat No 21 30 22 4,Rail TS32/35, in Spec 1125 1/6/1996 Stud type terminal 12 mm stud *96/p198 Cables,Terminals-rail Phoenix Phoenix Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted UHV150M12/M12,Cat No 21 30 23 7,Rail TS32/35, in Spec 1126 1/6/1996 Stud type terminal 12 mm stud *96/p199 Cables,Terminals-rail Entrelec Entrelec Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted M35/26.FF,Cat No 115 140 23,Rail TS32/35, in Spec 1127 1/6/1996 Stud type terminal *96/p2 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 003 BRB 930 Prior to line 50VDC 12F4B (Neutral), WB&S, QN1 1/6/1996 *96/p20 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 043 BRB 933 Prior to line 50VDC, 8F4B (Neutral slow pick-up), 1/6/1996 WB&S,QSPA1 *96/p200 Cables,Terminals-rail Entrelec Entrelec Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted M120/35.FF,Cat No 115 146 15,Rail TS32/35, in Spec 1128 1/6/1996 Stud type terminal *96/p201 Cables,Terminals-rail Entrelec Entrelec Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted M300/42.FF,Cat No 115 149.20,Rail TS32/35, in Spec 1129 1/6/1996 Stud type terminal *96/p202 Cables,Terminals-rail Entrelec Entrelec Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted M35/26EE,Cat No 115.151.12,Rail TS32/35, in Spec 1130 1/6/1996 Stud type terminal *96/p203 Cables,Terminals-rail Entrelec Entrelec Heavy Duty Feed Through Terminal Approved, Listed Prior to mounted M150/35EE,Cat No 115 156 17,Rail TS32/35, in Spec 1131 1/6/1996 Stud type terminal *96/p204 Cables,Terminals-rail Kilppon Klippon Test / Disconnect Terminal SAKC10,Cat Approved, Listed Prior to mounted No 032402NP,Rail TS32, 1 plug bolt in Spec 1132 1/6/1996 *96/p205 Cables,Terminals-rail Kilppon Klippon Test / Disconnect Terminal SAKC10, Cat Approved, Listed Prior to mounted No 032412NP,Rail TS32, 2 plug bolt in Spec 1133 1/6/1996 *96/p206 Cables,Terminals-rail Kilppon Klippon Test / Disconnect Terminal SAKT1,Cat No Approved, Listed Prior to mounted 43792,Rail TS32,Limited Application. Vital circuits in Spec 1134 1/6/1996 special case by case approval *96/p207 Cables,Terminals-rail Entrelec Entrelec Test / Disconnect Terminal M10/16.SN1, Approved, Listed Prior to mounted Cat No 115 376.23,Rail TS32/35 in Spec 1135 1/6/1996 *96/p208 Cables,Terminals-rail Entrelec Entrelec Test / Disconnect Terminal M6/8STP,Cat Approved, Listed Prior to mounted No 115 277.20,Rail TS32/35 in Spec 1136 1/6/1996 *96/p209 Cables,Terminals-rail Entrelec Entrelec Test / Disconnect Terminal MU10/13.SN3, Approved, Listed Prior to mounted Cat No 199 021 10,Rail TS32/35 in Spec 1137 1/6/1996 *96/p21 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 043 BRB 933 Prior to line 50VDC, 8F4B ,WB&S,QSPA1 base 1/6/1996

7 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p210 Cables,Terminals-rail Entrelec Entrelec Test / Disconnect Terminal M6/8ST1,Cat Approved, Listed Prior to mounted No 115 237.10,Rail TS32/35,Non vital circuits only in Spec 1138 1/6/1996 *96/p211 Cables,Terminals-rail Entrelec Entrelec Test / Disconnect Terminal M4/6SB,Cat Approved, Listed Prior to mounted No 115.436.00,Rail TS32/35,Limited Application. Vital in Spec 1139 1/6/1996 circuits special case by case approval *96/p212 Cables,Terminals-rail Kilppon Fuse Holders Klippon Terminal SAKS1,Cat No Approved, Listed Prior to mounted 19112,Rail TS32, 25 x 5 Indicator Fuse - in Spec 1140 1/6/1996 max 6.3 amps *96/p213 Cables,Terminals-rail Kilppon Fuse Holders Klippon Terminal SAKS1/35,Cat No Approved, Listed Prior to mounted 50152,Rail TS35, 25 x 5 Indicator Fuse - in Spec 1141 1/6/1996 max 6.3 amps *96/p214 Cables,Terminals-rail Kilppon Fuse Holders Klippon Terminal SAKS3,Cat No Approved, Listed Prior to mounted 21112,Rail TS32, 1" x 1/4" non indicating fuse - in Spec 1142 1/6/1996 max 13 amps *96/p215 Cables,Terminals-rail Kilppon Fuse Holders Klippon Terminal SAKS3/35,Cat Approved, Listed Prior to mounted No 66742,Rail TS35, 1" x 1/4" non indicating fuse - in Spec 1143 1/6/1996 max 13 amps *96/p216 Cables,Terminals-rail Kilppon Fuse Holders Klippon Terminal SAKS3,Cat No Approved, Listed Prior to mounted 24892,Rail TS32, 11/4" x 1/4" fuse - max 10 amps in Spec 1144 1/6/1996 *96/p217 Cables,Terminals-rail Kilppon Fuse Holders Klippon Terminal SAKS3/35,Cat No Approved, Listed Prior to mounted 66752,Rail TS35,11/4" x 1/4" fuse - max 10 amps in Spec 1145 1/6/1996 *96/p218 Cables,Terminals-rail Kilppon Fuse Holders Klippon Terminal SAKS5,Cat No Approved, Listed Prior to mounted 35942,Rail TS32, Neozed fuse - 20, 25, 35, 50, in Spec 1146 1/6/1996 63 amps *96/p219 Cables,Terminals-rail Kilppon Fuse Holders Klippon Terminal SAKS5/35,Cat No Approved, Listed Prior to mounted 50212,Rail TS35,Neozed fuse - 20, 25, 35, 50, 63 in Spec 1147 1/6/1996 amps *96/p22 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 063 BRB 934 Prior to line 50VDC, 8F4B (Neutral slow release), 1/6/1996 WB&S,QSRA1 *96/p220 Cables,Terminals-rail Wago Fuse Holders Wago Terminal Cat No.282 - 126,Rail Approved, Listed Prior to mounted TS35, 25 x 5 mm indicating fuse - 10 amp max. in Spec 1148 1/6/1996 *96/p221 Cables,Terminals-rail Wago Fuse Holders Wago Terminal Cat No.282 - 127,Rail Approved, Listed Prior to mounted TS32, 25 x 5 mm indicating fuse - 10 amp max. in Spec 1149 1/6/1996 *96/p222 Cables,Terminals-rail Wago Fuse Holders Wago Terminal Cat No.282 - 128,Rail Approved, Listed Prior to mounted TS35, 11/4" x 1/4" fuse - 10 amp max in Spec 1150 1/6/1996 *96/p223 Cables,Terminals-rail Wago Fuse Holders Wago Terminal Cat No.282 - 129,Rail Approved, Listed Prior to mounted TS32, 11/4" x 1/4" fuse - 10 amp max in Spec 1151 1/6/1996 *96/p224 Cables,Terminals-rail Entrelec Fuse Holders Entrelec Terminal M10/12.SF1,Cat Approved, Listed Prior to mounted No.111 035.05,Rail TS32/35,25 x 5 mm fuse – in Spec 1152 1/6/1996 max 6.3 amps *96/p225 Cables,Terminals-rail Entrelec Fuse Holders Entrelec Terminal M10/13.SF2,Cat Approved, Listed Prior to mounted No.119 014.11,Rail TS32/35,1¼ x ¼ fuse – in Spec 1153 1/6/1996 max 16 amps *96/p226 Cables,Terminals-rail Entrelec Fuse Holders Entrelec Terminal M10/16SF,Cat Approved, Listed Prior to mounted No.115 377.24,Rail TS32/35,1¼ x ¼ fuse to – in Spec 1154 1/6/1996 max 16 amps *96/p227 Cables,Terminals-rail Entrelec Fuse Holders Entrelec Terminal MB25/30SF,Cat Approved, Listed Prior to mounted No.116.305.26,Rail TS32/35,Neozed fuse in Spec 1155 1/6/1996 20, 25, 35, 50, 63 amps *96/p228 Cables,Terminals-rail Kilppon Klippon Earthing Terminal EK1,Cat No.32290, Approved, Listed Prior to mounted Rail TS32,Single conductor in Spec 1156 1/6/1996 *96/p229 Cables,Terminals-rail Kilppon Klippon Earthing Terminal EK2,Cat No.32310, Approved, Listed Prior to mounted Rail TS32,Two conductors in Spec 1157 1/6/1996

8 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p23 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 063 BRB 934 Prior to line 50VDC, 8F4B ,WB&S,QSRA1 base 1/6/1996 *96/p230 Cables,Terminals-rail Kilppon Klippon Earthing Terminal SAKE35,Cat No.14440, Approved, Listed Prior to mounted Rail TS32,Single conductor in Spec 1158 1/6/1996 *96/p231 Cables,Terminals-rail Wago Wago Earthing Terminal Cat No.282 - 107,Rail Approved, Listed Prior to mounted TS35,Two conductors - max 7/0.85 in Spec 1159 1/6/1996 *96/p232 Cables,Terminals-rail Wago Wago Earthing Terminal Cat No.282 - 108,Rail Approved, Listed Prior to mounted TS32,Two conductors - max 7/0.85 in Spec 1160 1/6/1996 *96/p233 Cables,Terminals-rail Wago Wago Earthing Terminal Cat No.284 - 107,Rail TS35 Approved, Listed Prior to mounted in Spec 1161 1/6/1996 *96/p234 Cables,Terminals-rail Wago Wago Earthing Terminal Cat No.284 - 108,Rail TS32 Approved, Listed Prior to mounted in Spec 1162 1/6/1996 *96/p235 Cables,Terminals-rail Wago Wago Earthing Terminal Cat No.283 - 107,Rail Approved, Listed Prior to mounted TS35,Two conductors - max 7/1.7 in Spec 1163 1/6/1996 *96/p236 Cables,Terminals-rail Wago Wago Earthing Terminal Cat No.283 - 108,Rail Approved, Listed Prior to mounted TS32,Two conductors - max 7/1.7 in Spec 1164 1/6/1996 *96/p237 Cables, terminal lugs and Utilux Insulated lugs,Utilux Prior to tools 1/6/1996 *96/p238 Cables, terminal lugs and Cable Insulated lugs,Cable Accessories, Approval letter Prior to tools Accessories PSZ:TP, 1/6/1996

*96/p239 Cables, terminal lugs and Carroll Insulated lugs,Carroll Terminal Co,Double grip, Approval letter, Prior to tools various 1/6/1996 *96/p24 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 027 BRB 932 Prior to line 50VDC, 12F4B (DC Biased AC Immune), 1/6/1996 WB&S,QBA1 *96/p240 Cables, terminal lugs and Davico Insulated lugs,Davico,DVP1 (pin,red),DVP2 Not approved Prior to tools (pin, blue),DVP5 (pin, yelo), 1/6/1996 *96/p241 Cables, terminal lugs and AMP? Faston lugs for CSEE, J/S,AMP,110 series No alternatives Prior to tools accepted 1/6/1996 *96/p242 Cables, terminal lugs and Utilux Non-insulated tubular lugs,Utilux Prior to tools 1/6/1996 *96/p243 Cables, terminal lugs and Cable Non-insulated tubular lugs,Cable Accessories Prior to tools Accessories 1/6/1996 *96/p244 Cables, terminal lugs and Bootlace ferrules,a,b,c Prior to tools 1/6/1996 *96/p245 Cables, terminal lugs and Utilux Cast traction lugs,Utilux Prior to tools 1/6/1996 *96/p246 Cables, terminal lugs and Cable Cast traction lugs,Cable Accessories Prior to tools Accessories 1/6/1996 *96/p247 Cables, terminal lugs and Exectronics Cast traction lugs,Exectronics Prior to tools 1/6/1996 *96/p248 Cables, terminal lugs and Exectronics Crimping tool - multi-jaw (modified), Blue die rendered Prior to tools Exectronics,Klippon CT16 (modified), inoperative 1/6/1996

*96/p249 Cables, terminal lugs and Cabac Crimping tool - multi-jaw (modified),Cable Blue die rendered Prior to tools Accessories,Cabac HP3, HP3/1 (modified), inoperative 1/6/1996

*96/p25 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 027 BRB 932 Prior to line 50VDC 12F4B ,WB&S,QBA1 base 1/6/1996 *96/p250 Cables, terminal lugs and Klippon Crimping tool - multi-jaw (modified),Klippon, Blue die rendered Prior to tools Klippon CT16 (modified) inoperative 1/6/1996 *96/p251 Cables, cable markers Critchley Alphanumeric slip-on rings,Critchley , Prior to 'Z' marker 1/6/1996

9 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p252 Cables, cable markers Weidmuller Alphanumeric slip-on rings,Weidmuller Letter 14.3.96, Prior to Klippon,'Partex' type PA01, PA02, * 96/0302 1/6/1996

*96/p253 Cables, cable markers Grafoplast Clear sleeve & Insert,Grafoplast Prior to 1/6/1996 *96/p254 Cables, cable markers Critchley Computer-printable heatshrink sleeves, For SSI plugs , Prior to Critchley,Type HS032, Letter 14.3.96, 1/6/1996 * 96/0301 *96/p255 Cables, cable markers Brady Clear sleeve & insert, and Computer-printable *96/0703 Prior to heatshrink sleeves,Brady,'Duramark' & 1/6/1996 'Permasleeve' *96/p256 Cables, cable markers Brady Clear sleeve & insert, and Computer-printable *98/0501 Prior to heatshrink sleeves,Brady,'Multi-Mark' 1/6/1996 *96/p257 Cables, multicore and power Olex Multicore cables listed in Spec 1011,Olex Supplier T&C Prior to Agreement 1/6/1996 *96/p258 Cables, multicore and power MM Multicore cables listed in Spec 1011,MM Subject to Prior to inspection 1/6/1996 *96/p259 Cables, multicore and power Pirelli Multicore cables listed in Spec 1011,Pirelli Subject to Prior to inspection 1/6/1996 *96/p26 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 028 BRB 932 Prior to line 50VDC, 8F8B (DC Biased AC Immune), 1/6/1996 WB&S,QBA1 *96/p260 Cables, multicore and power Olex Power cables listed in Spec 1012,Olex Supplier T&C Prior to Agreement 1/6/1996 *96/p261 Cables, multicore and power MM Power cables listed in Spec 1012,MM Subject to Prior to inspection 1/6/1996 *96/p262 Cables, multicore and power Pirelli Power cables listed in Spec 1012,Pirelli Subject to Prior to inspection 1/6/1996 *96/p263 Cables, bonding Olex Bonding cables, copper/hypalon listed in Supplier T&C Prior to Spec 1014,Olex Agreement 1/6/1996 *96/p264 Cables, bonding MM Bonding cables, copper/hypalon listed in Subject to inspection Prior to Spec 1014,MM 1/6/1996 *96/p265 Cables, bonding Pirelli Bonding cables, copper/hypalon listed in Subject to Prior to Spec 1014,Pirelli inspection 1/6/1996 *96/p266 Cables, bonding Olex Bonding cables, copper/PVC listed in Supplier T&C Prior to Spec 1014,Olex Agreement 1/6/1996 *96/p267 Cables, bonding MM Bonding cables, copper/PVC listed in Subject to Prior to Spec 1014,MM inspection 1/6/1996 *96/p268 Cables, bonding Pirelli Bonding cables, copper/PVC listed in Subject to Prior to Spec 1014,Pirelli inspection 1/6/1996 *96/p269 Cables, bonding Olex Bonding cables, aluminium/ hypalon listed Supplier T&C Prior to in Spec 1014,Olex Agreement 1/6/1996 *96/p27 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 028 BRB 932 50VDC Prior to line 8F8B ,WB&S,QBA1 base 1/6/1996 *96/p270 Cables, audio and data Olex Twin 7/0.5 audio cable for track circuits to Supplier T&C Prior to Spec 1015,Olex Agreement 1/6/1996 *96/p271 Cables, audio and data MM Twin 7/0.5 audio cable for track circuits to Subject to Prior to Spec 1015,MM inspection 1/6/1996 *96/p272 Cables, audio and data Pirelli Twin 7/0.5 audio cable for track circuits to Subject to Prior to Spec 1015,Pirelli inspection 1/6/1996 *96/p273 Cables, audio and data Twin 7/0.5 mm Data cable for SSI Prior to 1/6/1996 *96/p274 Cables, fire safe & fire rated Huber & Suehner Fire-rated twin ,Huber & Suehner,Radox Prior to 1/6/1996

10 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p275 Track circuit, components CSEE AF Jointless,CSEE,UM71 complete Prior to 1/6/1996 *96/p276 Track circuit, components WB&S AF Jointless,WB&S,FS2500 complete Formal Prior to type approval 1/6/1996 dated *96/p277 Track circuit, components ML AF Jointless,ML,TI 21 complete Type approval Prior to not completed 1/6/1996 *96/p278 Track circuit, components WB&S AF Traction Immune - with insulated joints, *96/0502 (Interim) Prior to WB&S,FS2600 1/6/1996 *96/p279 Track circuit, components GEC High voltage Impulse,GEC-A, Prior to Jeumont-Schneider complete. 1/6/1996 *96/p28 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 049 BRB 961 Prior to line 50VDC, 2x6F2B (DC biased AC Immune Twin), 1/6/1996 WB&S,QBBA1 *96/p280 Track circuit, components Wabco, Pulsat High voltage Impulse,Wabco,Pulsat Approval not Prior to issued. 1/6/1996 *96/p281 Track circuit, components ABW AC 6 ohm track resistor, ABW Prior to 1/6/1996 BRB power supply - DC501, AF track circuit power supply Prior to *96/p281A Power Supply Unit Exectronics E12009 24V 4.4A 1/6/1996 Track circuit, components AC Feed Transformer, Store 47 Prior to *96/p282A Exectronics 1/6/1996 *96/p283 Track circuit, components WB&S DC 2 ohm track resistor,WB&S Prior to 1/6/1996 *96/p284 Track circuit, components WB&S DC 4 ohm track resistor,WB&S Prior to 1/6/1996 *96/p285 Track circuit, components WB&S DC Track feed set - Store 72,WB&S Prior to 1/6/1996 *96/p286 Track circuit, components ABW DC Track feed set - Store 72,ABW Prior to 1/6/1996 *96/p286A Track circuit, components Exectronics DC Track feed set - Store 72 - Exetronics Prior to E17009 1/6/1996 *96/p287 Track circuit, components WB&S DC Track feed set - Store 72-Q,6 volt, Prior to 1 amp, 2-unit Q-rack mounting,WB&S 1/6/1996 *96/p288 Track circuit, components Exectronics DC Track feed set - Store 72-Q,6 volt, Prior to 1 amp, 2-unit Q-rack mounting,EXT, 1/6/1996 * Exectronics *96/p289 Track circuit, components ABW DC Track feed set - Store 70,ABW Prior to E01001 1/6/1996 *96/p289A Track circuit, components Exectronics DC Track feed set - Store 70 - Exetronics Prior to E01001 1/6/1996 *96/p289A1 Track circuit, components Exectronics DC Track feed set 1.3V, 10A with battery back up - Store Prior to 70V1 1/6/1996 *96/p29 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 049 BRB 961 Prior to line 50VDC, 2x6F2B ,WB&S,QBBA1 base 1/6/1996 *96/p290 Track circuit, components WB&S DC - AC Immune,Track feed set - Prior to BR 867,WB&S,RA5-9 1/6/1996 *96/p291 Track circuit, components DC - AC Immune,Track feed set - Prior to BR 867,DML,TR27 1/6/1996 *96/p292 Track circuits, Impedance & WB&S AC - 50 Hz,1000 A/rail,WB&S,MJS Prior to Electrolysis bonds 1/6/1996 *96/p293 Track circuits, Impedance & ABW AC - 50 Hz,1000 A/rail,ABW,Macolo 1000 Prior to Electrolysis bonds 1/6/1996

11 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p294 Track circuits, Impedance & WB&S AC - 50 Hz,2000 A/rail,WB&S,2000R Prior to Electrolysis bonds 1/6/1996 *96/p295 Track circuits, Impedance & ABW AC - 50 Hz,2000 A/rail,ABW,Macolo Prior to Electrolysis bonds 2000/R 1/6/1996 *96/p296 Track circuits, Impedance & GEC AF Resonated,1000 A/rail,GEC-A, Prior to Electrolysis bonds CIT1400-CT 1/6/1996 *96/p297 Track circuits, Impedance & WB&S AF Resonated,2000 A/rail,WB&S, 19.8.1991 Prior to Electrolysis bonds 2000R/AF 1/6/1996 *96/p298 Track circuits, Impedance & ABW AF Resonated,2000 A/rail,ABW, Prior to Electrolysis bonds Macolo 2000/AF 1/6/1996 *96/p299 Track circuits, Impedance & ABB AF Resonated,2000 A/rail,ABB, Prior to Electrolysis bonds ML TI 4000 1/6/1996 *96/p3 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 003 To fit BRB 930, Prior to line 50VDC, 12F4B , WB&S, QN1 base 1/6/1996 *96/p30 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 017 BRB 961 Prior to line 50VDC, 2x4F4B (DC biased AC Immune 1/6/1996 Twin),WB&S,QBBA1 *96/p300 Track circuits, Impedance & GEC High voltage impulse,1000 A/rail, Prior to Electrolysis bonds GEC-A,CIT1400-CT1 1/6/1996 *96/p301 Track circuits, Impedance & WB&S High voltage impulse,2000 A/rail, 16.8.1991 (interim) Prior to Electrolysis bonds WB&S,2000P 1/6/1996 *96/p302 Track circuits, Impedance & GEC High voltage impulse,2000 A/rail, Prior to Electrolysis bonds GEC-A, CIT2000-A 1/6/1996 *96/p303 Track circuits, Impedance & ABW Electrolysis Bond Choke,ABW,Store 54 Prior to Electrolysis bonds 1/6/1996 *96/p303A Track circuits, Impedance & Exectronics Electrolysis Bond Choke,ABW,Store 54 Prior to E06001 Electrolysis bonds 1/6/1996 *96/p304 Points, machines WB&S AC,WB&S,M3A Mk2 Prior to 1/6/1996 *96/p305 Points, machines WB&S AC,WB&S,84M Prior to 1/6/1996 *96/p306 Points, machines WB&S AC,WB&S,D84M Prior to 1/6/1996 *96/p307 Points, machines Nippon AC Nippon,KA1211C Prior to 1/6/1996 *96/p308 Points, machines Nippon AC Nippon,KA1211B Prior to 1/6/1996 *96/p309 Points, machines Nippon AC Trailable ,Nippon,KA1401C Prior to 1/6/1996 *96/p31 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 017 BRB 961 Prior to line 50VDC, 2x4F4B ,WB&S,QBBA1 base 1/6/1996 *96/p310 Points, machines WB&S AC Trailable ,WB&S,T84M Prior to 1/6/1996 *96/p311 Points, machines WB&S AC Trailable ,WB&S,TD84M Prior to 1/6/1996 *96/p312 Points, machines WB&S DC,WB&S,M3A Mk2 Prior to 1/6/1996 *96/p313 Points, Electropneumatic WB&S VALVE UNIT,WB&S,Style 'S' Prior to 1/6/1996 *96/p314 Points,detectors WB&S WB&SmStyle U5A Prior to 1/6/1996 *96/p315 Points,detectors ABB ABB-ML Prior to 1/6/1996

12 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p316 Points,detectors WB&S WB&S,HM2, HM3 Prior to 1/6/1996 *96/p317 Signals GEC Signal Heads - Main,GEC-A Prior to 1/6/1996 *96/p318 Signals WB&S Signal Heads - Main,WB&S Prior to 1/6/1996 *96/p319 Signals Aldridge Signal Heads - Main, Aldridge, 03/09/2002,1993 Prior to memo \sigstan\ 1/6/1996 sigstd\aldsigac.doc

*96/p32 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 172 BRB 943 Prior to line 50VDC, 2HF4B (DC biased AC Immune 1/6/1996 contactor),WB&S,QBCA1 *96/p320 Signals Montrose Signal Heads - Main,Montrose Prior to 1/6/1996 *96/p321 Signals GEC Signal Heads - shunt & subsidiary,GEC-A Prior to 1/6/1996 *96/p322 Signals Aldridge Signal Heads - shunt & subsidiary,Aldridge Prior to 1/6/1996 *96/p323 Signals WB&S Signal Heads - shunt & subsidiary,WB&S Prior to 1/6/1996 *96/p324 Signals GEC SIgnal Head - running turnout,GEC-A Prior to 1/6/1996 *96/p325 Signals Aldridge SIgnal Head - running turnout,Aldridge Prior to 1/6/1996 *96/p326 Signals WB&S SIgnal Head - running turnout,WB&S Prior to 1/6/1996 *96/p327 Signals WB&S Signal head - tunnel,WB&S Prior to 1/6/1996 *96/p328 Signals Aldridge Signal head - tunnel,Aldridge,LED lamp unit Prior to 1/6/1996 *96/p329 Signals WB&S Shunt / Point Ind'r,WB&S Prior to 1/6/1996 *96/p33 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 172 BRB 943 Prior to line 50VDC, 2HF4B ,WB&S,QBCA1 base 1/6/1996 *96/p330 Signals ABB/ML Dwarf Position Light,ABB/ML Prior to 1/6/1996 *96/p331 Signals WB&S Dwarf Position Light,WB&S Prior to 1/6/1996 *96/p332 Signals Route indicator - miniature multilamp Prior to 1/6/1996 *96/p333 Signals GEC Route indicator - stencil,GEC-A Prior to 1/6/1996 *96/p334 Signals Aldridge Route indicator - stencil,Aldridge Prior to 1/6/1996 *96/p335 Signals WB&S Route indicator - stencil,WB&S Prior to 1/6/1996 *96/p336 Train Stops WB&S Electropneumatic,WB&S,JA Prior to 1/6/1996 *96/p337 Train Stops WB&S Electric,WB&S,JAH Prior to 1/6/1996 *96/p338 Power supply, emergency Telemecanique Contactors,50 amp,T/M*,LC1-D638, FULL Prior to change-over * Telemecanique 1/6/1996

13 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p339 Power supply, emergency Contactors,100 amp,T/M*,CV1-GB FULL Prior to change-over 1/6/1996 *96/p34 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 160 BRB Prior to line 966F4 50VDC, 2HF4F4B (DC biased AC 1/6/1996 Immune contactor),WB&S,QBCA1 *96/p340 Power supply, emergency Elettrotecnica Contactors,100 amp,ETS**, FULL Prior to change-over Scientifica ** Elettrotecnica Scientifica 1/6/1996 *96/p341 Power supply, emergency Contactors,150 amp,T/M*,CV1-HB FULL Prior to change-over 1/6/1996 *96/p342 Power supply, emergency Contactors,150 amp,ETS** FULL Prior to change-over 1/6/1996 *96/p343 Power supply, emergency Contactors,200 amp,T/M*,CV1-JB FULL Prior to change-over 1/6/1996 *96/p344 Power supply, emergency Contactors,200 amp,ETS** FULL Prior to change-over 1/6/1996 *96/p345 Power supply, emergency Powerline Changeover - electronic high-speed, Note - approval of Prior to change-over Powerline,SC2000, new installations of 1/6/1996 this equipment has been suspended *96/p346 Power supply, DC supply ABW Store 74 , 12 volt, 20 amp,ABW Full Prior to units-general 1/6/1996 *96/p346A Power supply, DC supply Exectronics Store 74 , 12 volt, 20 amp Exetronics FULL Prior to Superseded by units-general 1/6/1996 30A units *96/p347 Power supply, DC supply ABW Store 74,12 volt, 30 amp and 40 amp, ABW Full Prior to units-general 1/6/1996 *96/p347A Power supply, DC supply Exectronics Store 74,12 volt, 30 amp and 40 amp Full Prior to E01002 units-general 1/6/1996 *96/p348 Power supply, DC supply ABW Store 103 50 volt, 2.5 amp,ABW Full Prior to units-general 1/6/1996 *96/p348A Power supply, DC supply Exectronics Store 103 50 volt, 2.5 amp Full Prior to E12002 units-general 1/6/1996 *96/p348A1 Power supply, DC supply Exectronics Store 103 50 volt, 2 amp filtered Full Prior to E12033 units-general 1/6/1996 *96/p349 Power supply, DC supply WB&S Store 103 50 volt, 2.5 amp,WB&S Full Prior to units-general 1/6/1996 *96/p349A Transformers Exectronics Signal Lighting 40VA Store 16 Full Prior to 1/6/1996 *96/p35 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 160 BRB 966F4 Prior to line 50VDC, 2HF4F4B ,WB&S,QBCA1 base 1/6/1996 *96/p350 Power supply, DC supply O'DG Store 103 50 volt, 2.5 amp,O'DG Full Prior to units-general 1/6/1996 *96/p350A Transformers Exectronics Signal Lighting 30VA Store 17 Full Prior to 1/6/1996 *96/p351 Power supply, DC supply Telectran Store 103 50 volt, 2.5 amp,T/T*, Full Prior to units-general * Telectran 1/6/1996 *96/p351A Transformers Exectronics Power isolation transformer 240/120V,500VA (Store 57) Full Prior to E18001 1/6/1996 *96/p352 Power supply, DC supply WB&S JTC PSU 24 volt, 4.4 amp,WB&S Full Prior to units-general 1/6/1996 *96/p352A Transformers Exectronics Power isolation transformer 240/120V,1.5kVA(Store 62) Full Prior to E18122 1/6/1996 *96/p353 Power supply, DC supply GEC() JTC PSU 24 volt, 4.4 amp, Full Prior to units-general Gayrad,GEC-Alsthom Gayrad 1/6/1996

14 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p353A Transformers Exectronics Power isolation transformer 240/120V, 3kVA (Store 64) Full Prior to E18149 1/6/1996 *96/p354 Surge protection All lightning and surge protection FULL Prior to components and materials 1/6/1996 listed in Spec 712 *96/p354A Transformers Exectronics Power isolation transformer 120V/240V, with 2x2GPO Full Prior to E18041 1/6/1996 *96/p355A Power Supply units - DC Exectronics Power supply 50V, 0.2A DC, unfiltered (Store 87) Full Prior to E12001 1/6/1996 *96/p356 Cables, Route material, Corflo 'material efficient' (corrugated) ,All uses except Prior to conduit conduit ,Vinidex,Corflo 100 HD ULX & URX - 1/6/1996 Memo 2.9.94, ULX & URX in steel or concrete pipe - Memo 7.9.94

*96/p356A Power Supply units - DC Exectronics Power supply 50V 7A DC, no-break supply (Store 92) Prior to E12023 1/6/1996 *96/p357 Cables, Route material, Flexible continuous conduit Class 8, *96/0401.Sizes Prior to conduit IPC,Type PE80, MDPE 110, 90, 63 mm. 1/6/1996 Installed by ploughing. Not for ULX. *96/p357A Power Supply units - DC Exectronics 24V/15A unfiltered single channel power supply Prior to E12019 1/6/1996 *96/p358 Test Equipment, JWA Combination bell & insulation test set,JWA Prior to miscellaneous 1/6/1996 Test units *96/p358A Power Supply units - DC Exectronics 50 volt, 20A Store 95, no-break supply Prior to E12019 1/6/1996 *96/p359 Power supply, detectors-earth GEC ELD 120 VAC,GEC,XG 1902 Prior to leakage 1/6/1996 *96/p359A Power Supply units - DC Exectronics 24V/4ADC Store 98 ,no-break , filtered supply Prior to 1/6/1996 *96/p36 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code BRB 966F4X Prior to line 12VDC, 2HF4F4B (DC biased AC Immune 1/6/1996 Contactor),WB&S,QBCA1 *96/p360 Power supply, detectors-earth ML ELD - 50VDC,ML,D5 Full Prior to leakage 1/6/1996 *96/p360A Power Supply units - DC Exectronics Store 103, 24 volt, 2.5 amp, unfiltered, unregulated supply Full Prior to E12002 1/6/1996 *96/p360A1 Power Supply units - DC Exectronics Store 103, 24V/2.A, filtered, supply Full Prior to E12033 1/6/1996 *96/p361 Power supply, detectors-earth ML ELD 120 VAC,ML,D3 Full Prior to leakage 1/6/1996 *96/p361A Power Supply units - DC Exectronics Store 107, 24 volt, 5 amp, unfiltered, unregulated supply Full Prior to E12042 1/6/1996 *96/p362 Power supply, detectors-earth ML ELD 120/50V AC/DC,ML,D6 Full Prior to leakage 1/6/1996 *96/p363 Power supply, detectors-earth MRD ELD 12 VDC,MRD *95/1202 Prior to leakage 1/6/1996 *96/p363A Power Supply units - DC Exectronics Power supply 24V 5A for TI212,Westinghouse and ABB Prior to track circuits 1/6/1996

15 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p364 Power supply, detectors-earth MRD ELD 120/50 VAC/DC,MRD *95/1202 Prior to leakage 1/6/1996 *96/p364A Track Feed Unit Exectronics Power supply TR17 and TR27 for AC immune and DC Prior to E12005 & immune track feeds 1/6/1996 E12006 *96/p365 Power supply, detectors-earth MRD ELD 120/50 VAC/DC,MRD *95/1202 Prior to leakage 1/6/1996 *96/p366 Power supply, detectors-earth Leonard ELD 50-650 VAC/DC,L.E.,LE51 *96/0504 Prior to leakage Electronics 1/6/1996 *96/p366A Track Circuit components Exectronics Resistor, track, ER2.2 Jeumont Schneider track resistor Prior to 1/6/1996 *96/p367 Modems Dataplex, Dataplex, Netcomm, and Maestro PSTN modems for Meet Specified Prior to Netcomm, and general purpose. requirements 1/6/1996 Maestro *96/p367A Relay Panel Exectronics Non-vital relay panel Prior to E13002 1/6/1996 *96/p368 Modems OSD OSD136 Fibre Optic Modem Single Mode Not for new Prior to installations 1/6/1996 *96/p368A Lightnig and Surge Protection Exectronics VAP panel (Old design superseded by the use of FULL Superseded Prior to E14013, Triggered Spark Gaps.) 1/6/1996 E14085, E14086, E14087 *96/p369 Power supply TRISAN TRISAN Switch mode AC to DC power supples FULL Prior to 1/6/1996 *96/p369A Lightnig and Surge Protection Exectronics Old designs superseded. Triggered Spark Gaps used in FULL Prior to E14013, new designs 1/6/1996 E14085, E14086, E14087 *96/p37 Relays, vital-miniature plug-in, Westinghouse Base, Relay BRB Code BRB 966F4X Prior to line 12VDC, 2HF4F4B ,QBCA1 base 1/6/1996 *96/p370 Power supply Powerware Powerware True Online UPS for SSI interlocking FULL Prior to 1/6/1996 *96/p370A Lightnig and Surge Protection Exectronics IDP Panel Prior to Superseded 1/6/1996 *96/p371 Telemetry equipment Alstom Alstom PMUX FULL Prior to 1/6/1996 *96/p372 Telemetry equipment Alstom Alstom Sigmap FULL Prior to 1/6/1996 *96/p373 Telemetry equipment EDMI EDMI Combiner/Splitter FULL Prior to 1/6/1996 *96/p374 Telemetry equipment EDMI EDMI Diversity Link Controller Not for new Prior to installations 1/6/1996 *96/p375 Telemetry equipment EDMI EDMI Railmaster, and Railmaster compact FULL Prior to 1/6/1996 *96/p376 Telemetry equipment Ericisson Ericisson JZA711, and JZA721 Not for new Prior to installations 1/6/1996 *96/p377 Telemetry equipment IBM Compatible PC's for running non-safety critical Comply with Prior to applications Specified 1/6/1996 requirements *96/p378 Telemetry equipment RSA RSA SSI Logger FULL Prior to 1/6/1996 *96/p379 Telemetry equipment Westinghouse Westinghouse S2 telemetry FULL Prior to 1/6/1996

16 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p38 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code xxx BRB Prior to line 966F7/4 120VAC, 2HF4F4B (AC Contactor 1/6/1996 for direct SSI output),WB&S,QNHXC1, (14 Febrary, 1993) *96/p380 Control System Ericisson Ericisson JZA715 Not for new Prior to installations 1/6/1996 *96/p381 Control System VDU control system by James Fuller Restricted to Junee Prior to Albury 1/6/1996 *96/p385 Noise suppression RS Contact Suppressor from RS 210-364 As per circuit Prior to design. 1/6/1996 *96/p386 Points, machines McKenzie & AC, McKenzie & Holland M2 Not normally for Prior to Holland new installations 1/6/1996 *96/p387 Points, machines McKenzie & AC, McKenzie & Holland M2D Not normally for Prior to Holland new installations 1/6/1996 *96/p388 Points, machines WB&S AC, WB&S, M23A Prior to 1/6/1996 *96/p389 Points, machines WB&S DC,WB&S, M70 Mk 3 Prior to 1/6/1996 *96/p39 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code xxx BRB 93x Prior to line 120VAC, 2HF4F4B,WB&S,QNHXC1 base 1/6/1996 *96/p390 Points, machines Siemens AC, Siemens, HA Not normally for Prior to new installations 1/6/1996 *96/p391 Points, machines GEC(Alstom) AC, GEC (Alstom), HW4121 Not normally for Prior to new installations 1/6/1996 *96/p392 Points, machines GEC(Alstom) AC, GEC (Alstom), HW4400 Not normally for Prior to new installations 1/6/1996 *96/p393 Points equipment Westinghouse Westinghouse Clawlock drive layout Full Prior to 1/6/1997 *96/p394 Points equipment VAE VAE Tangential (Assymetric Switch Rail) points layout for Full Prior to WB&S Co M3A Point Machine 1/6/1998 *96/p395 Points equipment PRE PRE Clawlock Drive layout FULL Prior to 1/6/1999 *96/p396 Points equipment PRE PRE Tangential (Assymetric Switch Rail) points layout for FULL Prior to WB&S Co M3A Point Machine 1/6/2000 *96/p397 Batteries SAFT SAFT SBL135 Nicad battery for level crossings FULL *96/p398 Batteries Sonnenschein Sonnenschein A400 series Dryfit sealed lead acid battery FULL for general float charge applications *96/p399 Level Crossing equipment Western Cullen Western Cullen type 3590B Boom mechanism Not for new purchases *96/p4 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 004 BRB 930 Prior to line 50VDC, 8F8B (Neutral), WB&S,QN1 1/6/1996 *96/p40 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 011 BRB 935 Prior to line 50VDC, 11F4B (Mag. Latched), WB&S,QL1 1/6/1996 *96/p400 Level crossing equipment Westinghouse Westinghouse EB Boom mechanism Not for new purchases *96/p401 Level crossing equipment Harmon Harmon Model C1B Boom mechanism Not for new purchases *96/p402 Level crossing equipment Harmon Harmon Model C1A Boom mechanism Not for new purchases *96/p403 Level crossing equipment Harmon Harmon Model H1 Boom mechanism Not for new purchases *96/p404 Level crossing equipment Western Cullen Western Cullen Hayes Type 3590 Boom mechanism Not for new Hayes purchases

17 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p406 Track circuit, components exectronics AC Feed Transformer 200VA 120V-120V/6V-24V-2V- Prior to 2VAC, (Store 51) 1/6/1996 *96/p407 Transformers exectronics Signal lighting 5VA 120V/12VAC (Store 1) Prior to E11001 1/6/1996 *96/p408 Transformers exectronics Signal lighting transformer tunnel type (Store 3), Signal Prior to lighting 40VA 1/6/1996 *96/p409 Transformers exectronics Signal lighting 30VA 120V/8V-2V (Store 18) Prior to 1/6/1996 *96/p41 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 011 BRB 935 Prior to line 50VDC, 11F4B ,WB&S,QL1 base 1/6/1996 *96/p410 Test Equipment Exectronics Track Shorting Clip Prior to E17012 1/6/1996 *96/p411 Power Supply Unit - DC exectronics Battery charger 24V, 20A DC, (Store 86) Prior to E01003 1/6/1996 *96/p412 Power Supply Unit - DC exectronics 50V/2.5ADC Store 90 Prior to E12004 1/6/1996 *96/p413 Power Supply Unit - DC exectronics 50V/2ADC Store 96; Battery charger Prior to E12025 1/6/1996 *96/p414 Signalling Rack Exectronics Mounting base 30 module NSI Prior to E04002 1/6/1996 *96/p415 Signalling Rack Exectronics Label, mounting channel NSI Prior to E04004 1/6/1996 *96/p416 Signalling Rack Exectronics Universal mounting bracket for CSEE&JS Prior to E04001 1/6/1996 *96/p417 Transformers Exectronics SL35 Signal head transformer Prior to 1/6/1996 *96/p418 Resistor Exectronics 6 and 4 ohm track resistor Prior to E17010 and 1/6/1996 E17011 *96/p419 test Equipment Exectronics Non-vital Relay Panel 54-way with 1 test socket Prior to E13002 1/6/1996 *96/p42 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 008 BRB 935 Prior to line 50VDC, 8F6B (Mag. Latched),WB&S,QL1 1/6/1996 *96/p420 Power Supply Exectronics Transformer /Rectifier 50V/2.5ADC,TS1020D Prior to E12016 1/6/1996 *96/p421 Power Supply Exectronics Transformer /Rectifier TS1024D Prior to E12018 1/6/1996 *96/p422 Power Supply Exectronics Transformer /Rectifier 50V/0.5DC, TS1029 Prior to 1/6/1996 *96/p423 Power Supply Exectronics CSEE BRB Adapter plate Prior to E11007 1/6/1996 *96/p424 Track Circuit components Exectronics Compensating capacitors REC25AN & REC35AN Prior to E17003 and 1/6/1996 E17004 *96/p426 Surge protection Exectronics Surge arrester Sankosha 290GT Prior to E14015 1/6/1996 *96/p427 Surge protection Exectronics Surge arrester Sankosha 700GT Prior to E14017 1/6/1996 *96/p428 Surge protection Exectronics Surge arrester Sankosha 350D Prior to E14018 1/6/1996 *96/p429 Track Circuit components Exectronics Impedance shielding panel Prior to E11005 1/6/1996 *96/p43 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 008 BRB 935 Prior to line 50VDC, 8F6B,WB&S,QL1 base 1/6/1996 *96/p430 Enclosure exectronics ESML general purpose stainless steel enclosure Prior to E08007 1/6/1996

18 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p431 exectronics Interference sensor-paired ferrite coils PR No:F79465 Prior to E11026 1/6/1996 *96/p432 Switch exectronics Thermal cut-out switch, transformer Prior to E18015 1/6/1996 *96/p433 Test Equipment exectronics Track Shunt Tester Prior to E17013 1/6/1996 *96/p44 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code BDGJX BRB Prior to line 935X 12VDC, 11F4B (Mag. Latched), 1/6/1996 WB&S,QL1 *96/p45 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code BDGJX BRB 935X Prior to line 12VDC 11F4B ,WB&S,QL1 base 1/6/1996 *96/p46 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 101 BRB 938X Prior to line 2F2B (4 ohm DC Neutral Track),WB&S,QT1 1/6/1996 *96/p47 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 101 BRB 938X Prior to line 2F2B ,WB&S,QT1 base 1/6/1996 *96/p48 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code BDEGX BRB Prior to line 938X 24VDC 8F8B (DC Neutral Track), 1/6/1996 WB&S,QT2 *96/p49 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code BDEGX BRB 938X Prior to line 24VDC, 8F8B ,WB&S,QT2 base 1/6/1996 *96/p5 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 004 BRB 930 Prior to line 50VDC, 8F8B , WB&S, QN1 base 1/6/1996 *96/p50 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 110 BRB 966F2 Prior to line 2F2B (9 ohm AC Immune DC Track), 1/6/1996 WB&S,QTA1 *96/p51 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 110 BRB 966F2 Prior to line 2F2B ,WB&S,QTA1 base 1/6/1996 *96/p52 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code ADEKS BRB Prior to line 938X 4F 2MB (DC neutral Track with metal 1/6/1996 to metal Back contacts),WB&S,QTM1 *96/p53 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code ADEKS BRB 938X Prior to line 4F 2MB ,WB&S,QTM1 base 1/6/1996 *96/p54 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code BCEGX BR Prior to line 946X 12VDC (Slow to release Timer), 1/6/1996 WB&S,QTD4 *96/p55 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code BCEGX BRB 946X Prior to line 12VDC ,WB&S,QTD4 base 1/6/1996 *96/p56 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code BDGHX BRB Prior to line 962X 12VDC 5F2B (Slow to pick-up 1/6/1996 Timing Relay),WB&S,QTD5 *96/p57 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code BDGHX BRB 962X Prior to line 12VDC 5F2B ,WB&S,QTD5 base 1/6/1996 *96/p58 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code BDFHX BRB Prior to line 962X 50VDC 5F2B (Slow to pick-up 1/6/1996 Timing Relay),WB&S,QTD5 *96/p59 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code BDFHX BRB 962X Prior to line 50VDC 5F2B ,WB&S,QTD5 base 1/6/1996 *96/p6 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code ABCFX BRB Prior to line 930X 12VDC, 8F8B (Neutral), WB&S,QN1 1/6/1996 *96/p60 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code BEGHX BRB Prior to line 962X 50VDC 4F3B (Slow to pick-up Timing 1/6/1996 Relay),WB&S,QTD5 *96/p61 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code BEGHX BRB 962X Prior to line 50VDC 4F3B ,WB&S,QTD5 base 1/6/1996

19 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p62 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code ACELM BRB 949 Prior to line 50VDC, 1F3B (Slow to pick-up Timing Relay), 1/6/1996 WB&S,QCJ1 *96/p63 Relays, vital-miniature plug-in, Westinghouse Base, Relay BRB Code ACELM BRB 949 Prior to line 50VDC, 1F3B,QCJ1 base 1/6/1996 *96/p64 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code ADFJS BRB 949 Prior to line 50VDC, 1F3B (Slow to pick-up Timing Relay), 1/6/1996 WB&S,QCJ1 *96/p65 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code ADFJS BRB 949 Prior to line 50VDC, 1F3B,WB&S,QCJ1 base 1/6/1996 *96/p66 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 082 BRB 93X Prior to line 105ma DC, 4F2B (Slow release lamp proving), 1/6/1996 WB&S,QSR3 *96/p67 Relays, vital-miniature plug-in, WB&S Base Relay BRB Code 082 BRB 93X 105ma Prior to line DC, 4F2B (With full wave rectifier), 1/6/1996 WB&S,QSR3 base *96/p68 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code ABCDK BRB 941, Prior to line 4F2B (AC slow release Lamp Proving), 1/6/1996 WB&S,QECX1 *96/p69 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code ABCDK BRB 941 4F2B, Prior to line WB&S,QECX1 base 1/6/1996 *96/p7 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code ABCFX BRB 930X Prior to line 12VDC, 8F8B, WB&S, QN1 base 1/6/1996 *96/p70 Relays, vital-miniature plug-in, WB&S Transformer-Rectifier Unit,110VAC/50V DC Prior to line Code ABCDJK QXR1,WB&S,QXR1 1/6/1996 *96/p71 Relays, vital-miniature plug-in, WB&S Base, Unit QXR1 code ABCDJK,WB&S,QXR1 Prior to line 1/6/1996 *96/p72 Relays, vital-miniature plug-in, GEC Contact clips - BRB relay base,GEC,'Z' type type approval Prior to line withdrawn 1/6/1996 *96/p73 Relays, Track (other than WB&S AC Vane Plug-in ,WB&S,VT1 Prior to BRB) 1/6/1996 *96/p74 Relays, Track (other than WB&S DC Full-size Plug-in,WB&S,BT1B Prior to BRB) 1/6/1996 *96/p75 Relays, Track (other than WB&S DC Shelf,WB&S,DN11 Prior to BRB) 1/6/1996 *96/p76 Relays, Track (other than GEC Impulse - Jeumont,GEC-A,NCO CVTH 2.4.04 Prior to BRB) 1/6/1996 *96/p77 Relays, Full Size Plug -in WB&S Relay, Flashing for Level Crossings,WB&S, Discontinued Prior to PTF3 1/6/1996 *96/p78 Relays, Full Size Plug -in WB&S Plugboard for level crossing flasher relay, Discontinued Prior to WB&S,PTF3 base 1/6/1996 *96/p79 Relays, Full Size Plug -in WB&S SAFEFLASH' Failsafe level crossing flasher, *96/0501 Prior to WB&S,Part No 2650131001 (interim), 1/6/1996 *96/p8 Relays, vital-miniature plug-in, WB&S Relay Vital min plug-in Code 212 BRB 960 Prior to line 50VDC 2x6F2B (DC Neutral Twin Relay), 1/6/1996 WB&S,QNN1 *96/p80 Relays, non-vital Fuji General Purpose relays with octal and 11-pin Approved Prior to teminations 12 V DC, 3PDT,SRA ID 06600415, 1/6/1996 Fuji HH23PWT, listed in Spec 432 *96/p81 Relays, non-vital Omron General Purpose relays with octal and 11-pin Approved Prior to teminations 12 V DC, 3PDT,SRA ID 06600415, 1/6/1996 Omron MK3P-I, listed in Spec 432

20 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p82 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations 12 V DC,3PDT,SRA ID 06600415, 1/6/1996 Potter & Brumfield KRPA-90834, listed in Spec 432 *96/p83 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 12 V DC,3PDT,SRA ID 06600415, 1/6/1996 Idec Izumi RR3P-U, listed in Spec 432 *96/p84 Relays, non-vital Fuji General Purpose relays with octal and 11-pin Approved Prior to teminations 24 V DC,3PDT,SRA ID 06600522, 1/6/1996 Fuji HH23PWT, listed in Spec 432 *96/p85 Relays, non-vital Omron General Purpose relays with octal and 11-pin Approved Prior to teminations 24 V DC,3PDT,SRA ID 06600522, 1/6/1996 Omron Mk3P-I, listed in Spec 432 *96/p86 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations24V DC,3PDT,SRA ID 06600522, 1/6/1996 Potter & Brumfield KRPA-90835, listed in Spec 432 *96/p87 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 24 V DC,3PDT,SRA ID 06600522, 1/6/1996 Idec Izumi RR3P-U, listed in Spec 432 *96/p88 Relays, non-vital Fuji General Purpose relays with octal and 11-pin Approved Prior to teminations 48 V DC,3PDT,SRA ID 06600514, 1/6/1996 Fuji HH23PWT, listed in Spec 432 *96/p89 Relays, non-vital Omron General Purpose relays with octal and 11-pin Approved Prior to teminations 48 V DC,3PDT,SRA ID 06600514, 1/6/1996 Omron MK 3P-I, listed in Spec 432 *96/p9 Relays, vital-miniature plug-in, WB&S Base, Relay BRB Code 212 BRB 960 Prior to line 50VDC, 2x6F2B ,WB&S,QNN1 base 1/6/1996 *96/p90 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations 48 V DC,3PDT,SRA ID 06600514, 1/6/1996 Potter & Brumfield KRPA-90836, listed in Spec 432 *96/p91 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 48 V DC,2PDT,SRA ID 06600514, 1/6/1996 Idec Izumi RR3P-U, listed in Spec 432 *96/p92 Relays, non-vital Fuji General Purpose relays with octal and 11-pin Approved Prior to teminations 48 V DC,3PDT,SRA ID 06600489, 1/6/1996 Fuji HH22PWT, listed in Spec 432 *96/p93 Relays, non-vital Omron General Purpose relays with octal and 11-pin Approved Prior to teminations 48 V DC,2PDT,SRA ID 06600489, 1/6/1996 Omron MK2P-I, listed in Spec 432 *96/p94 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations 48 V DC,2PDT,SRA ID 06600489, 1/6/1996 Potter & Brumfield KRPA-11DG-48, listed in Spec 432 *96/p95 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 48 V DC,2PDT,SRA ID 06600489, 1/6/1996 Idec Izumi RR2P-U, listed in Spec 432 *96/p96 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations 110V DC,3PDT, Potter & Brumfield 1/6/1996 KRPA-90837, listed in Spec 432 *96/p97 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 110V DC, 3PDT,Idec Izumi RR3P-U, 1/6/1996 listed in Spec 432 *96/p98 Relays, non-vital Potter & General Purpose relays with octal and 11-pin Approved Prior to Brumfield teminations 24 V AC, 3PDT,Potter & Brumfield 1/6/1996 KRPA-90838, listed in Spec 432

21 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *96/p99 Relays, non-vital Idec Izumi General Purpose relays with octal and 11-pin Approved Prior to teminations 24 V AC , 3PDT,Idec Izumi RR3P-U, 1/6/1996 listed in Spec 432 *97/0101 Control systems RIC Design CITEC for Windows panel Full, with 31/01/1997 conditions. *97/0102 Telemetry equipment Moscad MOSCAD Full, with 12/02/1997 conditions. *97/0103 Level crossing equipment Harmon Harmon HXP3 Provisional whilst under evaluation *97/0201 Cables, route RAILDUCT 2000 GLT System Interim with 21/02/1997 conditions *97/0301 Cables, jointing materials Alternate track connection (2xCadweld connections Full with conditions 07/03/1997 crimped into in line crimp) *97/0401 Interlocking systems WBSA WBSA MarkIIIA SSI Signal,Points and Data Link Modules Full, with conditions 04/04/1997

*97/0402 Cables, terminal lugs and Cable Crimp tool (range 6-50sqmm hex crimp) Full 17/04/1997 tools Accessories Cable Accessories type K05 *97/0501 Transformers Gayrad Gayrad SSI Isolating Transformers 120VA, twin 12/05/1997 120 VA& 500VA transformers only *97/0502 Track circuit, components Harmon Harmon TD4 track Circuit Full 12/05/1997 *97/0801 Train stops Westinghouse Westinghouse dry sump JA and JAH Trainstops. Full 27/08/1997 (Includes revised circuit controller) *97/1101 Interlocking systems WSA WSA SSI MPM MkIII and Mem Module MkIII restricted 04/11/1997 *97/1201 Telemetry equipment RIC, Control S-2000 Multi-drop field station FULL System *97/1202 Telemetry equipment RIC, Control S-2000 Master Telemetry Unit and Event logger FULL System *97/1203 Level crossing equipment Harmon MOTOPOL (Henkes & Harmon) Type NEG-8006A Full 22/12/1997 Aluminium/Fibreglass level crossing road boom arm *97/1204 Points equipment VAE VAE "Safe Roll" switch rollers for tangential turnouts Full (tangential 22/12/1997 turnouts only) *97/802 Power supply GEC(Alstom) GEC Alsthom / Gayrad Store 93 power supply restricted 05/08/1997 *98/0101 Surge protection Transtech Transtech TLPSF10AI FULL *98/0102 Surge protection Weidmuller Weidmuller DKU 48V AC/DC Catalogue 801928 As per Standard Circuits *98/0103 Surge protection Erico Erico UTB-9, UTB-18, UTB-36-R2, UTB-S, SLP10-K3F FULL surge protectors *98/0201 Signals, Light units Westinghouse Westinghouse Mainline daylight (212mm) LED signal units, Full 10/02/1998 red, yellow, green 12VDC, and 120VAC. RM4-RCFB25-A Red 120VAC, RM4-YCFB43-A Yellow 120VAC, RM4- GCFB25-A Green 120VAC, RM4-RCFB25-B Red 12VDC, RM4-YCFB43-B Yellow 12VDC, RM4-GCFB25-B Green 12VDC *98/0202 Signals Westinghouse Westinghouse R20 and RL20 mainline lacase and lamp Full 10/02/1998 cases. *98/0304 Interlocking systems Alstom Re-issue of approval certificate for *98/1004. (see above) Full (with 24/03/1999 Corrected naming and removed wire spacing requirement. conditions) Removed requirement for updated SSI Application manual

*98/0501 Cables, cable markers Critchley Cable marker system - Critchley Multimark Full 13/05/1998

22 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *98/0601 Points equipment Westinghouse Westinghouse D150 LH & RH and wheel Full 03/06/1998 crowder C150 LH and RH *98/0701 Power supply Cherokee Cherokee International QD5 & QD21 24 volt switch mode Full 21/07/1998 International power supplies. Type approval applies to a single panel with two units in parallel (2 x QD5 or 2 x QD21) rated at 50A & 90A respectively. *98/0801 Control systems US&S TDPro Train Control System Restricted *98/0901 Signals, Light units Alstom ALSTOM LED Tunnel Signal (red, yellow, green Restricted In 14/09/1998 LED units) Drawings S885-OOM-001 to 010 inclusive tunnel application only *98/0902 Power supply Exectronics Store 93 Power Supply manufactured by Exectronics Full 23/09/1998 *98/0903 Test equipment, insulation ABB ABB Combined Insulation & Continuity testing unit Full 28/09/1998 resistance testers(meggers) ABB Signal BELL-MEGGER BM-510 *98/1001 Level crossing equipment Leonard Battery Voltage Monitor & Alarm Leonard Full 13/10/1998 Electronic Electronics BVMA *98/1003 Interlocking systems Alstom Alstom Australia (GASL) Mk3 SSI Multiprocessor Full (with 30/10/1998 Module, type reference SS1003, GEC Mod State 1, conditions) fitted with: - Memory Module Type SS1331, with Interlocking Processor Program AL4303 Issue G2 operating as an interlocking OR - Memory Module Type SS1333, with single channel Program AL4373 Issue G2 operating single channel in the DWS. *98/1004 Interlocking systems Alstom Alstom Australia (GASL) Mk3 SSI Signal Modules, Full (with 30/10/1998 type reference SS3303, GEC Mod State 3, Issue conditions) state 4, BR Mod state 1. Software Version C4. Alstom Australia (GASL) Mk3 SSI Points Modules, type reference SS3103, GEC Mod State 1, Issue state 2, BR Mod state 1. Software Version C2. *99/0301 Cables, terminal lugs and Force 12 Force 12 (Denis Noble) Copper crimp link Full 23/03/1999 tools CK14095RSA for accepting two Cadweld tails (140mm2) 1 x 95mm2 cable *99/0302 Level crossing equipment Safetran Grade Crossing Predictor model GCP Provisional whilst 24/03/1999 3000ND. System under evaluation at Walcha Rd under evaluation Level Crossing Uralla Installed & commissioned 19/03/99. Provisional approval includes the use of Safetran's Shunt Enhancer. *99/0303 Interlocking systems Alstom Re-issue of approval certificate for *98/1003. (see above) Full (with 24/03/1999 Corrected naming and added approval for D2 & D4 conditions) software for use with the Mk2A SS1002A. Removed requirement for updated SSI Application manual

*99/0401 Control systems RIC Control RSA Control Systems Train Describer System Restricted to Systems Sydney and Strathfield *99/0402 Telemetry equipment Action Controls Kingfisher Series 2 RTU for Action Controls FULL *99/0403 Control systems Alstom SigView Signalling Operator Interface for Alstom FULL *99/0404 Telemetry equipment ADAM ADAM 4520 RS232/422 converter FULL *99/0501 Train stops WB&S JAH Limit Switch Assembly PC. No 3390200501 Full 26/05/1999 (Omron Sealed Limit Switch D4C series)

23 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *99/0701 Train stops WB&S JA and JAH trainstop exchange circuit controller unit Full 08/07/1999 with sealed contacts and screw terminals. (Exchange unit for existing train stops – not used in new train stops) For new Train stops refer *97/0801

*99/0702 Signals, Light units Alstom Alstom fibre optic main line route indicator Full 08/07/1999 *99/0703 Track circuit, components Adtranz Adtranz TI21 Main Line Jointless Track Circuit Full 15/07/1999 *99/0704 Interlocking systems Union Switch & Union Switch & Signal, Microlok 2 Restricted 23/07/1999 Signal *99/0801 Cables, jointing materials Force 12 Force 12 bifurcated rail connection (120sqmm Full 31/08/1999 cable to two 70mm tails) for connection to stud welds *99/0901 Points equipment Teksol SCHRECK-MIEVES "EKOS" switch rollers Z-200 Full Tangential 03/09/1999 single roller; V-200 dual roller; V-200 triple roller turnouts only (Australian Agent:- TEKSOL International P/L) *99/1001 Cables, terminal lugs and Carroll The following Carroll Crimp lugs: Full 11/10/1999 tools Red ring Copper Grip RC1-5 Red wire Pin Copper Grip WPC1 Red Lip Blade Copper Grip LBC1-5 Yellow wire pin Copper Grip WPC5 *99/1002 Train stops Westinghouse Westinghouse JAE electric trainstop Interim Pending 14/10/1999 Cancelled refer *00/0201 3 month trial *00/0101 Signals, Light units Aldridge Aldridge LED Turnout Repeater INTERIM 15-Jan-01 *00/0201 Train stops Westinghouse Westinghouse JAE electric trainstop Provisional Subject 03/02/2000 to inclusion of agreed modifications into production units

*00/0202 Signals, Light units Westinghouse Westinghouse 127mm diameter white 36 LED Approval for 18/02/2000 signal unit model no TR3-WCFB301A Guards Indicator 5/03/2001 withdrawn 28-04- 04. J Firmstone *00/0301 Cables, multicore and power Olex Composite multicore cable (3 x 7/0.85mm Full 22-Jun-00 and 4 x 0.5 mm) for trainstops – Olex Cables LHR P09 RW 007 BKVQ *00/0302 Signals, Light units Alstom Alstom Mk2 Mainline daylight Signal Units (212mm) Full – main line 30-Mar-00 medium range LED – signals Red, Yellow and Green 120VAC *00/0303 Signals, Light units Aldridge Aldridge Blue LED indicator light for emergency Full – for use in 31-Mar-00 telephones in underground railway. (conditional underground upon improved LED board terminal mounting) railway *00/0401 Signals, Light units Alstom Alstom Mk2 Subsidiary daylight Signal Units (127mm) Full – subsidiary 04-Apr-00 medium range LED – signals Red, Yellow, Green and Lunar White 120VAC *00/0402 Points equipment Teksol SCHRECK-MIEVES "EKOS" switch rollers Z-200 Full 60 kg 27-Apr-00 single roller; V-200 dual roller modified for RAC conventional 60 kg conventional tunouts timber sleepers or turnouts only concrete beams (Australian Agent:- TEKSOL International P/L) *00/0601 Telephones Relectronic Mining type telephones 2.5W and 7W (1043454 Full 07-Jun-00 Remech of & 1042324 respectively) rebuilt by Relectronic Mascot Remech of Mascot

24 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *00/0701 Signals, Light units Westinghouse Westinghouse 127mm diameter 36 LED signal units (Red, Yellow & Green) model No TR3-xCFB301A Short range for Tunnel use. *00/0801 Pneumatic Air assist unit for mechanical interlocking machines, Interim Full 29 Aug 2000 consists of compressor, air cylinder, valving. 17 May 2001 Air to cylinder pressure regulated and flow controlled. *00/0901 Telemetry equipment Dupline Dupline Restricted use of controls. *00/1001 Pneumatic INVENSYS INVENSYS (COMPAIR) 125 mm x 180 mm Interim -pending 13-Oct-00 latched and detected air cylinder for claw service trial lock operation. Cylinder fitted with Omron detection microswitches. *00/1002 Level crossing equipment Westinghouse Westinghouse Electronic Highway Crossing Bell Interim – pending 19-Oct-00 service trial *00/1003 Interlocking systems RAC Train Order Working System (TOWS) Full 31-Oct-00 incorporation Train Management and Control System (TMACS) ver 1.3 and GPS Watchdog *00/1101 Telemetry equipment RSA Modem Interface Communications card Full 15-Nov-00 developed by RSA North Coast. Hardware R2.0, Firmware V1.0. *00/1201 Signals, Light units Alstom Alstom LED Turnout Repeater (L/H, R/H & Both) INTERIM 08-Dec-00 D/02/343 *00/1202 Signals, Light units Westinghouse Westinghouse Turnout Repeater INTERIM 08-Dec-00 *01/0101 Telemetry equipment Blackbox RS232 Optoisolator SP400A-R3 FULL *01/0102 Surge protection Elsafe Elsafe 216600 series termination modules Listed items *01/0103 Surge protection Erico Erico DSF-6A-30, DSF-6A-150 power surge protectors FULL *01/0104 Surge protection Erico Erico TEC Transient Earth Clamp FULL *01/0201 Points equipment Adtranz 'Ebiswitch' in-bearer points mechanism Limited – axle 28-Feb-01 loads not over 25 tonne *01/0301 Signals, Light units Aldridge Aldridge Railway Signals - Repeat Signal Full 22-Mar-01 (4 White Lights) *01/0501 Points equipment Expert Tribologies (Hunter Valley) Dry Switch INTERIM pending 17-May-01 Plate Lubricant – Graphite based. full OH&S approval (Initial Trials carried out in the Hunter Valley) *01/0601 Surge protection Erico Erico Surge Protection Panel version of IVAP Interim 28-Jun-01 *01/0602 Level crossing equipment Aldridge Aldridge Railway Signals level crossing Full 29-Jun-01 advance warning light – yellow LED 125 or 200 mm diameter 12v (8 – 18 v) DC. *01/0603 Surge protection Erico Erico TSG1130-2S-NE primary surge protectors. FULL *01/0801 Points equipment Teksol Teksol (Schrek-Mieves) switch roller for AS Full 03-Aug-01 53 Kg switches Roller assembly only excluding mounting bracket *01/0802 Points equipment Teksol Teksol bracket assembly for 53 kg switch rollers Interim for 03-Aug-01 extended trials to determine if height adjustment is required

*01/0901 Wire Cambridge ETFE Teflon insulated twisted pair wire for Microlock Full 05/09/2001 Technologies and CBI systems as wire for safety applications. Part Mil- W-22759-16/16-0+9 twisted pair at greater than 15 twists per metre.

25 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *01/0902 Wire Cambridge ETFE Teflon insulated wire for Microlock and other Full 05/09/2002 Technologies CBI systems as wire for safety applications. Part 16-ACFZ- 1929 19/29awg 1.23mm 2 *01/1001 Cables, multicore and power Olex Twisted pair multicore signalling cable for outdoor use Full 26/10/2001 *01/1002 Power supply Powerbox Power Supply for Microlok by Powerbox FULL *01/1101 Telemetry equipment Tracktronics Tracktronics Diversity Link Controller Preliminary *01/1102 Modems OSD OSD136 Fibre Optic Modem Multi Mode FULL 01/10/2001 *01/1201 Signals, Light units Aldridge Aldridge Main Line daylight LED signal RL400 series Full 17/12/2001 212mm 120VAC Red, Yellow, and Green. *01/1203 Relays, vital-miniature plug-in, Westinghouse Westinghouse 12 volt QS2 6F-6B Full 17/12/2001 line *01/1204 Relays, vital-miniature plug-in, Westinghouse Westinghouse QBT1 2F-2B Full 17/12/2001 line *01/1205 Relays, vital-miniature plug-in, Westinghouse Westinghouse 12v QBBA1 2 x 4F-4B Full 17/12/2001 line *01/1206 Control systems RIC Control ATRICS Control System Restricted 20/12/2001 Systems (Sydenham only) *01/1207 Signals, Light units Westinghouse Westinghose 127mm diameter medium range LED signal Under review. (Red, Yellow, and Green) Medium range 120VAC TR3- xCFB501A for subsidiary signals. *01/1208 Level Crossing equipment Alstom Alstom LED light units FL-03 212mm Highway warning FULL lights. *01/1209 Level Crossing equipment Bradken 4-LED-BOARD As Boom arm light units. 10 volt. Under review. *02/0101 Transformers Alstom Data Link Isolation Transformer for SSI data links Approved 01-Dec-01 *02/0102 Power supply Harmonic filter for SSI 120VAC power supply Approved 21-Jan-02 *02/0103 Power supply, emergency AES Grid Grid Inverter (GGI) as a ECO from AES Subject to 17-Dec-01 change-over completion of trial *02/0301 Signals, Light units Alstom Alstom Mk2 Mainline daylight Signal Units (212mm) medium range LED – Red, Yellow and Green 12VDC for use with Microlok 2. *02/0302 Signals, Light units Alstom Alstom Mk2 Subsidiary daylight Signal Units (127mm) medium range LED – Red, Yellow, Green and Lunar White 12VDC for use with Microlok 2. *02/0303 Signals, Light units Alstom Stencil type LED lights 12VDC. Under approval Pending *02/0303 Signals, Light units Alstom LED miniature route indicator lights 12VDC / 120VAC Under approval Not issued J Firmstone *02/0304 Telemetry equipment Ampcontrol Ampcontrol iMAC Under test. *02/0501 Power supply Invensys Energy Powerware 9305 series UPS, SPM9305 System Parrallel Approved 08-May-02 Systems Module, External Battery cabinent, Line isolation transformer, and associated surge protection equipment.

*02/0502 Test Equipment-RCS Leonard Rail Current Sensors for measurement of rail currents interim- pending 23/05/2002 Electronics proper calibration certificates and 3 months field trials *02/0601 Signals, Light units Aldridge RL241 series 120VAC LED Standing man red pedestrian In-progress Not issued 05/06/2002 light. *02/0602 Power supply, emergency RIC Control 240VAC Power supply change over box. Under approval 05/06/2002 change-over Systems *02/0701 Signals, Light units Aldridge LED (white) Notice Board, 'Elec ' Under approval Not issued 19/07/2002 RecFind ?? J Firmstone *02/0702 Signals, Light units Aldridge LED (Light Blue), Guards Indicator Under approval Pending 24/07/2002 RecFind ?? J Firmstone *02/0703 Signals, Light units Alstom LED (Light Blue), Guards Indicator. R999-X0957 Under approval Pending 24/07/2002 RecFind ?? J Firmstone *02/0704 Signals, Light units Alstom LED Tri-colour. Medium. R999-X1066 Under approval Pending 24/07/2002 RecFind J Firmstone D/02/0238

26 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *02/0705 Level Crossing equipment Westinghouse LED Road Crossing Boom Gate Light Under approval Pending 24/07/2002 RecFind D/0382 J Firmstone

*02/0706 Signals, Light units Alstom LED Signal Repeater, reverse 'L'. R999-X1093 Under approval Pending 24/07/2002 RecFind J Firmstone D/02/343 *02/0801 Cables,Terminals-rail Phoenix Phoenix Cage Clamp Terminal Part ST 2,5-TWIN, Rail TS- Under approval Pending J Firmstone mounted 35, 600V, 20A, 7/0.67 *02/0802 System US&S Microlok 2 Approved Issued

*02/0802R1 Interlocking systems US&S Microlok 2 V5.1 Executive. Approved G. Hockings

*02/1001 Lightning Protection Panels- Exectronics New IVAP with triggerred spark gaps - manufactured by Approved Pending 22/10/2002 15A, 50A,100A, 150A, 200A, Exectronics 250A,etc *02/1101 Points CARL DAN CDP ZHV3 & ZHV2 INTEGRATED ROLLER SLIDE Approved Issued 05/11/2002 PEDDINGHAUS PLATES GMBH & Co. Ltd.

*02/1102 Signals, Light units Aldridge LED Mainline 200mm signals R,Y & G for 12Vdc Microlok Not approved for Not issued 27/11/2002 RecFind J Firmstone II new installations, D/02/492 20-1-04. *02/1103 Signals, Light units Aldridge LED Subsidiary 127mm signals R,Y,G & W for 12Vdc Not approved for Not issued 27/11/2002 RecFind J Firmstone Microlok II new installations, D/02/492 20-1-04. *02/1104 Signals, Light units Aldridge LED Stencil route indicator 125mm for 12Vdc Microlok II Not approved for Not issued 27/11/2002 RecFind J Firmstone new installations, D/02/492 20-1-04. *02/1201 Signals, Light units Aldridge LED Stencil 'U' light for 120Vac Full Not issued 11/12/2002 RecFind J Firmstone D/02/492 *03/0201 Level Crossing equipment Transtech Model PTS-VC-12VDC (0-3 Amp) Trip module Under approval Not issued RecFind J Firmstone D/03/282 *03/0301 Signals, Light units Alstom 12VDC LED Standing man red pedestrian light. In-progress, Not issued 07/03/2003 RecFind J Firmstone conditional D/02/425 *03/0401 Conduits Vinidex Electrical & communication conduits, cable covers Approved 03/04/2003 *03/0402 Signals, Light units Aldridge LED Subsidiary 127mm signals R,Y,G & W for 120Vac, for Interim Not issued 03/04/2003 TBA report not J Firmstone outdoor use. complete. *03/0403 Signals, Light units Aldridge LED Stencil 2 route indicator 125mm for 120Vac Interim Not issued 03/04/2003 TBA report not J Firmstone complete. *03/0404 Earth Leakage Detector MRD MRD type ELDAC/DC-AUTO earth leakage detector for AC Interim Pending 22/04/2003 TBA report not ???? and DC buses to 600 volts, with digital display and remote complete. interrogation *03/0405 Points Schwihag GmbH Schwihag IBSR integrated roller plate system Approved 22/04/2003 J Stanley *03/0501 Telemetry equipment NKA Kingfisher Telemetry, surge protection and wiring Approved Pending 22/05/2003 TBA report not G Hockings arrangement. complete. *03/0601 Signals, Light units Motpol LED bayonet lamp for existing boom gate lanterns as Approved Not issued 05/06/2003 D/03282 J Firmstone interim solution prior to boom upgrade. *03/0602 Control System Alstom Train Visibility System using Sigview. G. Hockings *03/0603 Signals, Light units Aldridge LED 'A' Light 200mm for 120Vac, Relay Interlocking only. Approved Pending 13/06/2003 RecFind J Firmstone Number Outdoor use. D/02/492 duplicated & has been changed to 0603.

*03/0701 Audible Warning Radio Spares Omni-directional multi-tone generator, for pedestrain Interim, awainting Not issued 17/07/2003 RecFind J Firmstone Components crossing. 90mm dia. Voltage 12Vdc.Part 285-2645 test confirmation D/02/425

27 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *03/0702 Audible Warning Radio Spares Omni-directional multi-tone generator, for pedestrain Interim, awainting Not issued 17/07/2003 RecFind J Firmstone Components crossing. 90mm dia. Voltage 120Vac.Part 626-113 test confirmation D/02/425 *03/0801 Signals, Light units Westinghouse LED White Light 140mm for 120Vac . Outdoor use; Approved Not issued 13/08/2003 RecFind J Firmstone Warning light. TR3-WCFB501-A D/03/211 *03/0802 Train detection - Frauscher Frauscher ACS2000 axle counter operating in 'isolated Interim approval for Recfind D/03/137 P Szacsvay Number mode' over turnouts live in-service trial withdrawn refer to *03/0903

*03/0803 Points Parker Hannifin 125 mm x 200 mm latched air cylinder - similar to approval Approved Not issued 27/08/2003 J Stanley *96/0601 except microswitches and actuators deleted

*03/0804 Signals, Light units Aldridge LED MLRI. 7x7 pixil array. Readability limited to 170m Interim Approval Not issued 27/08/2003 RecFind J Firmstone readability. Application: Low Speed Turnouts. D/03/272 *03/0901 Points RIC style"a" points control unit for ep points interim approval Not issued 03/09/2003 R FREEMAN *03/0902 Signals, Light units Westinghouse LED Tri-colour. 120Vac Relay interlocking only. Approval Not issued 05/09/2003 RecFind J Firmstone Conditional approval. withdrawn D/02/00238 24/09/08 *03/0903 Train detection - axle counter Frauscher Frauscher ACS2000 axle counter operating in 'isolated Interim approval for 09/09/2003 Recfind P Szacsvay mode' over turnouts live in-service trial D/03/137

*03/0904 Points - Swing nose crossing PRE (Pacific Rail Claw lock mechanism for 1 in 12 to 1 in 18 PRE swing Interim approval Not issued 23/09/2003 J Stanley Engineering) nose V crossings subject to satisfactory service

*03/0905 Points, machines Westinghouse D84M Mk2 dual control switch machine 110v AC - For Full approval - Not issued 26/09/2003 D Dunne claw lock operation *TRIAL/22 satisfactory completion *03/1001 Points - clawlock - hydraulic Cooper Fluids Pump unit for hydraulic clawlock points actuator Interim approval for Not issued 01/10/2003 D Dunne live in-service trial

*03/1101 Cables,Terminals-rail Weidmuller Weidmuller terminal ZDK2.5 /1.5, Cat Nos 1674300000 Limited Approval Pending 11/11/2003 P Szacsvay mounted and 168990000, and cross-connection type ZQV, for termination of multicore cables in Signal Control Panels *03/1201 Level Crossing Equipment Westinghouse Safetran S40 Level Crossing Boom Gate Mechanism Interim Approval for Not issued 10/12/2003 J Stanley (Safetran) in service Assessment *04/0201 Points - Swing Nose Crossing Westinghouse HM3 Detector and rodding modified to operate from a Limited Approval Not issued 23/02/2004 J Stanley swing nose crossing with claw locks - WBS drg 3301-186 for Glenfield 41,42 and 43 swing nose crossings only. *04/0301 Signals, Light units Westinghouse LED Tri-colour searchlight replacement. 12Vdc Relay Approval Withdrawn Withdrawn ARTC RecFind J Firmstone control. Restricted approval. withdrawn SC 11/02/2008 D/04/073 24/09/08 *04/0401 Disconnect terminals & feed Weidmuller Terminals ZTR2.5 and ZTR 2.5D- Weidmuller part number Approved 19/07/2004 19/07/2004 RecFind Siri through terminals 1608720000, replacement diode plug for this terminal is D/04/136 Kamalasuriya Weidmuller part number 1058560000 . *04/0501 ML track circuit tuning unit Exectronics ML track circuit tuning unit protector Interrim, on trial 25/05/2004 RecFind Siri protector D/04/135 Kamalasuriya *04/0502 Opto-isolator Black Box High speed opto- isolator type SP340A-R3 in place of Approved Issued 20/07/2004 RecFind Siri superceded SP400A opto isolator D/04/134 Kamalasuriya *04/0603 Timer relay OMRON Solid state timer H3YN -4 DC 12 Approved 03/06/2004 03/06/2004 RecFind Siri D/04/133 Kamalasuriya

28 of 29 Updated: 11/02/2008 List of Type Approved Signalling Equipment RIC

STAR No Categories Manufacturer Items Approval Status Certificate Approval Assessment Status Date Doc. ID. *04/0604 Signals, Light units Aldridge LED MLRI. Single string of LEDs. Readability limited to Interim approval Not issued 11/06/2004 RecFind J Firmstone 180m readability. Application: Low Speed Turnouts only. subject to trial D/02/492 outcome at Newcastle # 5 signal *04/0701 Traction bond Force-12 Force-12 single ended with bi-metal link BK 182/127 Approved 19/07/2004 19/07/2004 Recfind Siri D/04/137 Kamalasuriya *04/0702 Signals, Light units (new Aldridge Main line signals 213mm new power board and LED board design) design *04/0801 Power supply Leonard 12V Voltage regulator Approved Issued 06/08/2004 Recfind Siri Electronics D/04/155 Kamalasuriya *04/0802 Signals, Light units Westinghouse LED MLRI Theatre Type. Model TRI-L. Displays Interin Approval Not issued 18/03/2004 RecFind J Firmstone configured to suit each application. subject to final D/03/272 prototype being satisfactory. *04/0901 Level Crossing equipment Prime Electronics White LED Panel Indicator Kit for Level Crossing Test Box being evaluated Not issued 07/09/2004 RecFind J Firmstone & combined Test/Emergency Box. D/04 TBA *04/0902 Power supply Amtex 19" Rack mounting 120VAC/48VDC power supply- RM- being evaluated Not issued 23/09/2004 Siri JWS 600-48 Kamalasuriya *04/0903 Signals, Light units Aldridge LED Power Supply Module. Model RL403-*/1 & 2. Where Interim approval Not issued 30/09/2004 RecFind J Firmstone /1 denotes the present series of LED boards. subject to period of D/02/492 satisfactory service

*04/1101 Signals, Light units Westinghouse LED Miniature RI Stencil Type. Approved Not issued 03/11/2004 RecFind J Firmstone D/04/225 *04/1201 Cables Olex Cables Fire safe instrumentaion cables being evaluated Not used RecFind Siri D/04/???? Kamalasuriya *04/1202 Cables Pirreli Cables Fire safe instrumentaion cables being evaluated Not used RecFind Siri D/04/???? Kamalasuriya *04/1203 signal Lamp Aldridge/ SL35 long life 8000Hours lamp being evaluated Not used RecFind Siri D/04/???? Kamalasuriya *05/0201 Signals, Light units Westinghouse LED Turnout Repeater, main line, outdoor. Full size. Interin Approval Not issued 10/02/2005 RecFind J Firmstone subject to final D/0?????????? prototype being satisfactory. *93/0101 Track circuits, rail connections Erico Exothermic stud weld rail connection process, 6mm and Interim approval Not issued 14/01/1993 memo 14 Jan 12mm studs subject to period of 1993 satisfactory service

*93/0102 Track circuits, rail connections Thermoweld Exothermic stud weld rail connection process, 6mm and Interim approval Not issued 14/01/1993 memo 14 Jan 12mm studs subject to period of 1993 satisfactory service

*96/p405 Level crossing equipment Magnetic Pedestrian Swing Gates assembly MRG 3B-300 and MRG Approved Not issued Prior to 1/1/1996 Historical J Stanley Automation 3A-300 and ancillary equipment.

29 of 29 Updated: 11/02/2008