Sick Building Syndrome-A Case Study

Total Page:16

File Type:pdf, Size:1020Kb

Sick Building Syndrome-A Case Study Building and Environment, Vol. 26, No. 4, pp. 319-330, 1991. 0360-1323/91 $3.00+0.00 Printed in Great Britain. (!:) 1991 Pergamon Preu pie. Sick Building Syndrome-A Case Study Y. N. AU YEUNG* W. K. CHOW* VERONICA Y. K. LAM* The problem of 'sick buildi11g sy11drome · was i11ves1igated by carryi11g out a field survey on the library building of the Hong Kong Polytechnic. The environme111al conditions, indoor air quality a11d species of common bacteria were measured for a period offive months. The library staff were interviewed to get their subjective feelings on the enviro11ment. Results of this case study were presented a11d tlte relationship between those occupants' s11bjec1iuefeeli119, indoor environment and prevalence of symptoms was analysed. Measurement res11lts indicated tha1 indoor environmental co11ditions could generally be maintained up to widely acceptable standards. Yet, feedback from staff did 1101 show the expected consistency. INTRODUCTION suitable guideline? Such persistent low level symptoms may lead to subclinical infection which may eventually THE DEFINITION for 'sick building syndrome' has be converted to a clinical condition and result in absen­ been a controversial topic over the past years. Lots of teeism. Nevertheless, the decrease in productivity of professionals have been trying to define the problem but workforce is notorious and the impact of SBS is worth an internationally accepted standard still has not been investigating [7]. reached. On the other hand, symptoms of SBS are diffi­ As air-conditioned or sealed buildings such as offices, cult tO diagnose as they are dominated by sensory reac­ hotels and tertiary education institutions are potential tions about which only very little is known even from the traps in which unnoticed causes of SBS can exist, the medical point of view [I]. Researches in finding out the library building of the Hong Kong Polytechnic was there­ effects of SBS on human health are limited. fore chosen to be the subject of the case study. Objectives To simplify the situation, SBS may be described as a could be summarized as follows to find out : phenomenon that occurs in a building in which a pro­ portion of occupants experience varying degrees of low e the prevalence of the low level symptoms that char­ level sickness or discomfort which are nonspecific in acterized SBS as experienced by the staff; nature and are dominated by sensory reactions. Fur­ • the relationship between the degree of comfort ex­ thermore, symptoms brought into a building are not pressed by the staff and the corresponding indoor considered as symptoms ofSBS unless they are developed environmental conditions and the comparison with after an occupant enters the building and disappear very various widely accepted standards; and quickly upon his subsequent departure. • the relationship between the prevalence of symptoms, The sensory reactions are broadly classified by the degree of comfort experienced by occupants and WHO [2, 3], World Health Organization, into: indoor environmental conditions. e sensoric irritation in eye, nose or throat; e skin irritation; e neurotoxic symptoms; THE SURVEY e unspecified hyperreactions and The survey consisted of two main components : sub­ • odour and taste complaints. jective assessment and objective measurement. To obtain The exact causes ofSBS have not been identified. Vari­ subjective feeling, questionnaires (shown in Appendix A) ous past researchers [4, 5, 6] provided varying and some­ were distributed to library staff at the Circulation, times conflicting argument. Yet, the general consensus is Acquisition, Cataloguing, Serial, Special Collection and that they are related to indoor environmental variables Audio-Visual Sections as shown in Fig. I. Details about including physical factors like air temperature, chemical the low level symptoms such as dryness and irritation of factors like pollutants, biological factors like pollen of eyes, nose, throat, skin, headache, lethargy, dizziness etc. mould, and psychological factors [2]. as experienced by, staff were assessed. Effects of SBS on human health have not been rig­ Objective measurement was carried out at the same orously reported. There have been arguments about the time as subjective assessment was obtained to find out the attribution of illnesses to SBS. Should absenteeism be a environmental conditions and to determine the possible relationship between these variables. The survey ran from • Department of Building Services Engineering, Hong Kong October 1989 to February 1990. Environmental par­ Polytechnic, Hong Kong. ameters being measured included: 319 BAE 25:4-A 320 Y. N. Au Yeung et al. 80m Study Room for Visually Disabled Users (LJOIA) AUDIO-VISUAL MATERIALS .-.==========V.\~~~-.C..:~;:::~-:- AV Materials Counter THIRD FLOOR LIBRARY ENTRANCE Circulation Counter PODIUM FLOOR SPECIAL COLLECTIONS Serials Counter Starr Study Area (L013) UNBOUND PERIODICALS GROUND FLOOR I Cataloguing ..l..--~-/ I Section ·1 BOUND PERIODICALS Class nos QB·Z ~ Field Survey Location Fig. I. HKP Library layout plan. Physical aspects : -NO,(ppm) -air temperature (D.B. °C, W.B. 0 C) -S02 (ppm) -air velocity (m/s) -CO(ppm) -mean radiant temperature (0 C) -C02(ppm) -surface temperature (°C) -Formaldehyde (ppb). -illuminance level (tux) -noise level (dBA and the whole spectrum) -respirable dust particles (µg/m 3). Biological aspects: -Staph. epidermidis (CFU /m 3 of air) Chemical aspects : -Staph. aureus (CFU/m3 of air) -THC(ppm) -Bacillus (CFU/m 3 of air) -NO(ppm) -Penicil/ium (CFU/m3 of air). Sick Building Syndrome-A Case Study 321 FINDINGS respondents per survey, 84% claimed that they experi- The results of the survey are summarized in Tables l(a) enced one or more symptoms during office hours. The to l(g) while Table 2 lists the recommended values for average number of symptoms per respondent was three. various indoor environmental parameters. The variation was greatest for Circulation and Serial Sections in January with one and six symptoms per Prevalence of symptoms respondent respectively. Figure 2 shows the number of Out of the total 253 responses from the five surveys work related symptoms experienced by staff members. carried out in the months stated with an average of 50 Lethargy and dry symptoms were most prevalent and Table l(a). Acquisition Section at G/F Date 30 Oct. 27 Nov. 18 Dec. 22 Jan. 27 Feb. Thermal environment D.B. temp (0 C) 21.5 21 20 21.2 19 W.B. temp (°C) 18 17 16 16.5 15.3 R.H . (%) 72 69 69 63 70 Surface temp (°C) 18.5 20 19 20-21 17-18 Mean radiant temp (0 C) 22 22 21 22 19.5 Air velocity (m/s) 0.1 0.17 0.1 0.1-0.35 0.1-0.5 Visual environment Task illuminance 335--<i95 429 . 503 383-542 433-575 level (lux) Ambient illuminance 400-599 338 469 437-550 350-530 level (lux) Audio environment dBA 52-58 45-48 50-58 50-52 47-53 Linear 80--81 78-80 80-84 82-84 82-84 Table l(b). Serial Section at G/F Date 30 Oct. 27 Nov. 18 Dec. 22 Jan. 27 Feb. Thermal environment D.B. temp (0 C) 22.5 22.5 21 22 19.8 W.B. temp (°C) 18.5 17.5 16.5 17.5 17.2 R.H. (%) 68 60 65 65 78 Surface temp (0 C) 21-22 21-22 20-21 20-21 18 Mean radiant temp (°C) 23 23 21.5 22 18 Air velocity (m/s) 0.1 0.2 0.1 0.09 0.1 Visual environment Task illuminance 380-520 320-510 420-528 432-545 413-513 level (lux) Ambient illuminance 350-560 331-565 368-555 400-584 480-600 level (lux) Audio environment dBA 48-55 52-{)0 45-56 42-48 45-55 Linear 79-81 77-80 79--82 79-80 79-81 Table l(c). Circulation Section at P/F Date 30 Oct. 27 Nov. 18 Dec. 22 Jan. 27 Feb. Thermal environment D.B. temp (0 C) 22.3 21 20.5 20.8 19.5 W.B. temp (°C) 18 17 16.5 16 15.5 R.H . (%) 67 68 66 62 65 Surface temp (0 C) 22-24 20-21 19-20 17-18 17-18 Mean radiant temp (0 C) 22.8 21.7 21 21 19.5 Air velocity (m/s) 0.1 0.17 0.14 0.08 0.08 Visual environment Task illuminance 450-650 400-470 350-410 366-411 471-533 level (lux) Ambient illuminance 400-700 453-533 390-419 353-424 470-500 level (lux) Audio environment dBA 52-58 56-{)2 55--{)5 54--<iO 52-{)0 Linear 79--81 78-82 78-82 78-82 79--81 322 Y. N. Au Yeung et al. Table l(d). Special Collection Section at l/F Date 30 Oct. 27 Nov. 18 Dec. 22 Jan. 27 Feb. Thermal environment D.B. temp (0 C) 21.5 21 20 19 19.5 W.B. temp (0 C) 17 16 16 15 17.5 R.H.(%) 64 60 68 67 80 Surface temp (0 C) 19-20 19-20 18-20 17-18 18 Mean radiant temp (°C) 22.8 21.5 20.5 20.2 18 Air velocity (m/s) 0.1 0.18 0.1 0.1 0.1 Visual environment Task illuminance 411>-470 396-445 40()-450 405-428 576-598 level (lux) Ambient illuminance 313-400 265-450 3 lo-420 350-400 490-625 level (lux) Audio environment dBA 54 45-58 48-57 46-56 50-51 Linear 80 79-80 78-82 80-82 80-85 Table l(e). Audio-Visual Section at 3/F Date 30 Oct. 27 Nov. 18 Dec. 22 Jan. 27 Feb. Thermal environment D.B. temp (0 C) 22.5 21.3 21 18.5 19 W.B.
Recommended publications
  • Preparing HVAC Systems Before Reoccupying a Building by JOHN MCCARTHY, SC.D., C.I.H., MEMBER ASHRAE; KEVIN COGHLAN, C.I.H
    TECHNICAL FEATURE This article was published in ASHRAE Journal, January 2021. Copyright 2020 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. For more information about ASHRAE Journal, visit www.ashrae.org. Preparing HVAC Systems Before Reoccupying A Building BY JOHN MCCARTHY, SC.D., C.I.H., MEMBER ASHRAE; KEVIN COGHLAN, C.I.H. As states across the U.S. roll out new phases of reopening and ease social distanc- ing restrictions instituted to “flatten the curve” of infection from SARS-CoV-2 (the virus that causes COVID-19), commercial building owners and facility manag- ers are seeking direction in preparing their spaces to a return to near-normal levels of occupancy. World Health Organization (WHO) and Centers for Disease Control and Prevention (CDC) recommendations have focused on “de-densifying” spaces and disinfection of surfaces, while the ASHRAE Epidemic Task Force’s comprehen- sive Building Readiness guidance addresses strategies for preparing HVAC systems for buildings reopening after COVID-19 closures.1 Still, facility engineers have been wondering whether disinfecting their facility’s HVAC system is a further protective step to take to prepare for reopening—and about what else they should do. While no blanket answer exists to fit every scenario reduced loads or turned off as an energy-saving and every building type, the current science2 indicates measure. that, in general, disinfection of mechanical systems is not likely to be necessary. However, that doesn’t mean How SARS-CoV-2 Transmission Impacts Disinfection there isn’t work to be done—or risks to address before Recommendations reopening or expanding the number of occupants To understand why HVAC system disinfection may not in the space.
    [Show full text]
  • Position Document on Resiliency in the Built Environment
    ASHRAE and CIBSE Position Document on Resiliency in the Built Environment Approved by ASHRAE Board of Directors June 26, 2019 Approved by the CIBSE Board July 11, 2019 Expires June 26, 2022 © 2019 ASHRAE and CIBSE ASHRAE • 1791 Tullie Circle, NE • Atlanta, Georgia 30329-2305 • 404-636-8400 • www.ashrae.org CIBSE • 222, Balham High Road • London SW12 9BS • 0208 675 5211 • www.cibse.org © 2019 ASHRAE and CIBSE. For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without copyright holders' prior written permission. COMMITTEE ROSTER The ASHRAE and CIBSE Position Document on Resiliency in the Built Environment was developed by ASHRAE’s Resiliency in the Built Environment Position Document Committee formed on October 10, 2017, with David Under- wood as its chair. David Underwood Andrew Persily Retired NIST Oakville, ON, Canada Gaithersburg, MD, USA Scott Campbell Thomas Phoenix National Ready Mixed Concrete Association Clark Patterson Lee Milwaukee, WI, USA Greensboro, NC, USA Hywel Davies CIBSE Paul Torcellini London, United Kingdom Eastford, CT, USA Bill McQuade Chandra Sekhar AHRI National University of Singapore Arlington, VA, USA Singapore, Singapore The CIBSE Technology Committee was responsible for oversight of the CIBSE contribution to this position docu- ment. Cognizant Committees The chairperson of ASHRAE Technical Committee 2.10, Resilience and Security, also served as an ex-officio member: Jason DeGraw Arvada, CO, USA ASHRAE is a registered trademark in the U.S. Patent and Trademark Office, owned by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. © 2019 ASHRAE and CIBSE. For personal use only.
    [Show full text]
  • ASHRAE Position Document on Filtration and Air Cleaning
    ASHRAE Position Document on Filtration and Air Cleaning Approved by ASHRAE Board of Directors January 29, 2015 Reaffirmed by Technology Council January 13, 2018 Expires January 23, 2021 ASHRAE 1791 Tullie Circle, NE • Atlanta, Georgia 30329-2305 404-636-8400 • fax: 404-321-5478 • www.ashrae.org © 2015 ASHRAE (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAE's prior written permission. COMMITTEE ROSTER The ASHRAE Position Document on Filtration and Air Cleaning was developed by the Society's Filtration and Air Cleaning Position Document Committee formed on January 6, 2012, with Pawel Wargocki as its chair. Pawel Wargocki, Chair Dean A. Saputa Technical University of Denmark UV Resources Kongens Lyngby, Denmark Santa Clarita, CA Thomas H. Kuehn William J. Fisk University of Minnesota Lawrence Berkeley National Laboratory Minneapolis, MN Berkeley, CA H.E. Barney Burroughs Jeffrey A. Siegel Building Wellness Consultancy, Inc. The University of Toronto Johns Creek, GA Toronto, ON, Canada Christopher O. Muller Mark C. Jackson Purafil Inc. The University of Texas at Austin Doraville, GA Austin, TX Ernest A. Conrad Alan Veeck BOMA International National Air Filtration Association Washington DC Virginia Beach, VA Other contributors: Dean Tompkins Madison, WI for his contribution on photocatalytic oxidizers Paul Francisco, Ex-Officio Cognizant Committee Chair Environmental Health Committee University of Illinois Champaign, IL ASHRAE is a registered trademark in the U.S. Patent and Trademark Office, owned by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. © 2015 ASHRAE (www.ashrae.org). For personal use only.
    [Show full text]
  • ANSI/ASHRAE/ACCA Standard 180-2018
    ANSI/ASHRAE/ACCA Standard 180-2018 (Supersedes ANSI/ASHRAE/ACCA Standard 180-2012) Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems Approved by ASHRAE on June 11, 2018; by the Air Conditioning Contractors of America on May 13, 2018; and by the American National Standards Institute on June 11, 2018. ASHRAE® Standards are scheduled to be updated on a five-year cycle; the date following the Standard number is the year of ASHRAE approval. The latest edition of an ASHRAE Standard may be purchased on the ASHRAE website (www.ashrae.org) or from ASHRAE Customer Service, 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. E-mail: [email protected]. Fax: 678-539-2129. Telephone: 404-636-8400 (worldwide) or toll free 1-800-527-4723 (for orders in US and Canada). For reprint permission, go to www.ashrae.org/permissions. © 2018 ASHRAE and ACCA® ISSN 1041-2336 ASHRAE Standard Project Committee 180 Lead Cognizant TC: 7.3, Operation and Maintenance Management Co-Cognizant TCs: 2.4, Particulate Air Contaminants and Particulate Contaminant Removal Equipment; and TC 9.8, Large Building Air-Conditioning Applications SPLS Liaison: R. Lee Millies, Jr. Thomas L. Paxson*, Chair Kristin H. Heinemeier* Heather L. Platt* Donald R. Langston*, Vice-Chair Donald C. Herrmann Donald Prather* Richard A. Danks*, Secretary Peter C. Jacobs* Gregg A. Ray* Hywel Davies Michael J. Lawing* George Rodriguez* Bill R. Benito* Benjamin E. Lipscomb Dale T. Rossi* Michael Blazey Phil London* Robert J. Roth Glenn Friedman* Phil Maybee* Jeff O. Sturgeon* Michael W. Gallagher Marc Newman* John Warfield * Denotes members of voting status when the document was approved for publication ACCA–EI Standards Task Team 2018–2019 Phil Forner, Chair Warren Lupson Matt Todd Dave Galbreath, Vice-Chair Raymond Granderson Brent Ursenbach Danny Halel, Secretary Timothy Offord Tom Jackson Joe Pacella ASHRAE STANDARDS COMMITTEE 2017–2018 Steven J.
    [Show full text]
  • Assessment of Design Procedures for Vertical Borehole Heat Exchangers
    PROCEEDINGS, Fortieth Workshop on Geothermal Reservoir Engineering Stanford University, Stanford, California, January 26-28, 2015 SGP-TR-204 Assessment of Design Procedures for Vertical Borehole Heat Exchangers Eleonora Sailer1, David M.G. Taborda2 and James Keirstead2 1AECOM, Chelmsford, CM1 1HT, UK, formerly Imperial College London, UK 2Imperial College London, Dept. Civil & Environmental Engineering, London SW7 2AZ UK [email protected] Keywords: Borehole heat exchanger, low enthalpy systems, ground source heat, design guidelines ABSTRACT The use of ground source energy systems is a well-established method to provide low cost heating to buildings, diversify the energy mix and help meeting increasingly stricter sustainability targets. However, considerable uncertainties remain over their efficient design, with several standards, guidelines and manuals being proposed over the last few years. This paper aims at providing insight into the implications to the design of a vertical borehole heat exchanger of the adoption of different design procedures. The hypothetical case of a typical dwelling located in London, UK, is analysed in order to highlight the impact on the final design of the chosen methodology. Moreover, a parametric study using an analytical design procedure was performed to point out the influence of various factors, such as borehole characteristics and thermal properties of the ground. It is shown that there are considerable discrepancies between design methods and that uncertainties in some input parameters, such as the thermal properties of the ground, which for relatively small systems are often selected from tables rather than measured in situ, may have a substantial influence on the length of borehole required. 1. INTRODUCTION Borehole Heat Exchangers (BHE) are one type of Ground Source Heat Pump (GSHP) systems and are classified as low enthalpy geothermal systems since they make use of low temperature differences.
    [Show full text]
  • Humidity and Occupants Presentation
    Humidity and Occupants What the Latest in Humidity Research Means for You Presenters Matt Nowak North American Sales Manager Armstrong International Eric Brodsky, PE Director of Technology Research Products Inc. / Aprilaire / DriSteem Duncan Curd General Manager Nortec Humidity Ltd. Jeremy Wolfe National Sales & Marketing Manager CAREL USA Agenda 1. Fundamentals of Humidity • Key Terms and Definitions • How indoor humidity changes throughout the year • Where humidification matter most 2. Humidity and People • Historical Research • Impacts of moisture to the human body • Recent advances in humidity research 3. Recent Research • Microbiome Study Details • Example of Hospital Savings • Results and Recommendations 4. Humidity in Your Building • Technologies for Humidification • Cooling and Humidifying with Adiabatic Systems • Humidification with Steam • Case Studies / Installation Examples What is Humidity and How Do We Measure It? Humidity • The amount of water vapor in the air • Measured in “Absolute” or “Relative” terms Absolute Humidity • Mass of water in particular volume of air • Expressed as mass (grains/lbda or gw/kgda) Relative Humidity • Amount of water vapor in the air relative to how much it can hold at a given temperature (%) 25 20 15 Maximum Moisture Content Of Air Depends 10 5 0 On Air Temperature Grains Grains of/ Water Cubic Foot of Air 0 5 -5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 -10 100 Air Temperature (F) How Much Water Can the Air Hold? Air Heated From 10°F @ 100% RH to 70 °F 1 lb (kg) of Air Would Only Be Less Than 10% RH 35°F (2°C) 30 gr (2g/kg) The Psychrometric Chart Typical RH in Las Vegas, NV Typical Temps in Las Vegas, NV Need for Humidification Summer (July 19th) – 104F @ 10% RH = 72F @ 27.5% RH Winter (Dec.
    [Show full text]
  • Global Air-Conditioning Market Set for Growth and Technology Changes
    INDUSTRY NEWS This article was published in ASHRAE Journal, June 2020. Copyright 2020 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. For more information about ASHRAE Journal, visit www.ashrae.org. Global Air-Conditioning Market Set For Growth and Technology Changes BRACKNELL, BERKSHIRE, U.K.—Air conditioning already repre- GLOBAL HVAC AND BUILDING AUTOMATION CONTROL SYSTEMS (BACS) MARKET, 2019, $US BILLION sents the biggest segment of the global HVAC market, 51.4 62.4 44.4 8.7 18.9 and with rising global average temperatures, the need for cooling will keep growing, according to a BSRIA Commercial AC Residential AC Traditional Heating market report published in March. Renewable Heating BACS However, as the world’s focus will remain on the efforts SOURCE: BSRIA to limit global warming, the air-conditioning market DX SPLITS VS CHILLERS, BY VOLUME (COMPOUND ANNUAL GROWTH RATE, 2018-2024) will keep shifting toward more efficient products, the 14% use of refrigerants with lower global warming potential 12% and toward connectivity that will allow for remote moni- 10% toring of units and systems bringing vital energy and 8% operational efficiencies. 6% 4% In 2019 the global sales of air-conditioning units 2% increased by 2.3% year-on-year in volume and by 2.5% in 0% terms of USD value. Global Europe MEIA ASIA Pacific Americas In the United States, the AC market recorded overall Mini-VRF Maxi-VRF Multi-Splits Total Chillers SOURCE: BSRIA SOURCE: BSRIA growth in 2019, despite being a mature market, driven by a heathy economic growth, accessible and afford- three markets.
    [Show full text]
  • Air Conditioning and Refrigeration Chronology
    Air Conditioning and Refrigeration C H R O N O L O G Y Significant dates pertaining to Air Conditioning and Refrigeration revised May 4, 2006 Assembled by Bernard Nagengast for American Society of Heating, Refrigerating and Air Conditioning Engineers Additions by Gerald Groff, Dr.-Ing. Wolf Eberhard Kraus and International Institute of Refrigeration End of 3rd. Century B.C. Philon of Byzantium invented an apparatus for measuring temperature. 1550 Doctor, Blas Villafranca, mentioned process for cooling wine and water by adding potassium nitrate About 1597 Galileo’s ‘air thermoscope’ Beginning of 17th Century Francis Bacon gave several formulae for refrigeration mixtures 1624 The word thermometer first appears in literature in a book by J. Leurechon, La Recreation Mathematique 1631 Rey proposed a liquid thermometer (water) Mid 17th Century Alcohol thermometers were known in Florence 1657 The Accademia del Cimento, in Florence, used refrigerant mixtures in scientific research, as did Robert Boyle, in 1662 1662 Robert Boyle established the law linking pressure and volume of a gas a a constant temperature; this was verified experimentally by Mariotte in 1676 1665 Detailed publication by Robert Boyle with many fundamentals on the production of low temperatures. 1685 Philippe Lahire obtained ice in a phial by enveloping it in ammonium nitrate 1697 G.E. Stahl introduced the notion of “phlogiston.” This was replaced by Lavoisier, by the “calorie.” 1702 Guillaume Amontons improved the air thermometer; foresaw the existence of an absolute zero of temperature 1715 Gabriel Daniel Fahrenheit developed mercury thermoneter 1730 Reamur introduced his scale on an alcohol thermometer 1742 Anders Celsius developed Centigrade Temperature Scale, later renamed Celsius Temperature Scale 1748 G.
    [Show full text]
  • New Guidance for Residential Air Cleaners- ASHRAE Journal Sep 2019
    TECHNICAL FEATURE ©ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal at www.epa.gov. This article may not be copied nor distributed in either paper or digital form without ASHRAE’s permission. For more information about ASHRAE, visit www.ashrae.org. New Guidance for Residential Air Cleaners BY LEW HARRIMAN, FELLOW/LIFE MEMBER ASHRAE; BRENT STEPHENS, PH.D, MEMBER ASHRAE; TERRY BRENNAN, MEMBER ASHRAE As HVAC&R professionals, we in the ASHRAE community are sometimes asked ques- tions about residential indoor air quality (IAQ) and how to improve it. What contami- nants are most hazardous? How do I get rid of a particular smell? Should I use this air cleaner or that filter? Sadly, our friends and family generally lose patience when we helpfully suggest: “Well, it’s complicated. But just read Chapters 46, 60 and 62 in the ASHRAE Handbook—HVAC Applications, because there’s great information in there.” In general, we find that information seekers are frustrated by such helpful advice. Usually, the question is repeated (with some heat) in a form such as: “You’re the professional. Can’t you boil it down? What should I DO in my HOUSE?” Fortunately, two new resources can help you better mainstream and social media. When you get questions answer such questions. First, the ASHRAE Residential from friends and family about residential air filtration Indoor Air Quality Guide1 is a comprehensive summary of and air cleaners, you may find the U.S. Enivronmental IAQ for homes and apartments, written by our mem- Protection Agency’s recently updated publications help- ber colleagues and published by ASHRAE in 2018.
    [Show full text]
  • Large Passive House Building HVAC the New England Experience
    2020‐08‐19 1 Large Passive House Building HVAC The New England Experience Mike Woolsey, Certified Passive House Designer Member iPHA, ASHRAE Voting Member ASHRAE SPC 227P Passive Building Business Development Manager Swegon [email protected] +1 612 685 6519 Course credit: 1.0 PDH; 1.0 PHI CEU 2 Integrating HVAC into Large Passive House Building Design 2 1 2020‐08‐19 Learning Objectives 1. Understand the benefits of energy recovery ventilators in general, with special focus on their benefits to the Passive House project. 2. Understand the properties of energy recovery ventilators that are most valuable on Passive House projects. 3. Understand the limits of energy recovery ventilators when applied on Passive House projects. 4. Understand the integration of energy recovery ventilators in the Passive House design, with case studies. 3 Integrating HVAC into Large Passive House Building Design 3 Passive House Characteristics 4 2 2020‐08‐19 DRAMATIC ENERGY SAVINGS Approx90% Up to75% reduction in heating & cooling reduction in total energy usage. Introduction to Passive House www.naphnetwork.org 5 FROM EXPERIMENT TO POLICY 1st Modern Passive House: 1990 Introduction to Passive House www.naphnetwork.org 6 3 2020‐08‐19 BOLD IMPLEMENTATION BRUSSELS, 2015: All buildings, private, public, new and retrofitted mandated Passive House performance. EUROPE, 2020: Nearly zero-energy buildings. Introduction to Passive House www.naphnetwork.org 7 COMPLEX BUILDINGS IN VARIED CLIMATES Introduction to Passive House www.naphnetwork.org 8 4 2020‐08‐19 PASSIVE
    [Show full text]
  • Interpretation 62.2-2007-10 – November 8, 2011
    INTERPRETATION IC 62.2-2007-10 OF ANSI/ASHRAE STANDARD 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings Approved November 8, 2011 Request from: Katrin Klingenberg ([email protected]), Passive House Institute US (PHIUS), 110 South Race Street, Suite 202, Urbana, IL 61801. Reference: This request for interpretation refers to the requirements presented in ANSI/ASHRAE Standard 62.2-2007, Section 5.3 and Table 5.2, relating to continuous mechanical exhaust requirements for kitchens. Background: The Passive House Institute US is advocating and promoting the international Passive House Building Energy Standard to be widely adopted in the United States. The Passive House Building Energy Standard core technical piece is an optimized continuous balanced mechanical ventilation system. The supply and exhaust airflows required under this standard are determined a) by indoor air quality fresh air requirements based on occupants under consideration of the airtightness of the envelope and b) the exhaust air requirements based on the number of bathrooms and kitchens. Bathrooms require 24 cfm continuous exhaust and kitchens require 35 cfm continuous exhaust. The kitchen exhaust is part of the continuous balanced mechanical ventilation system with very high heat recovery efficiency and does not need to be vented directly to the outside. Charcoal filtration at the source of cooking is required before the kitchen exhaust air enters the kitchen exhaust intake. In fact, direct venting is to be avoided in a Passive House to minimize unnecessary heat loss through penetrations of the envelope and to optimize the overall energy balance of the home.
    [Show full text]
  • Meeting IAQ Needs with Enhanced Filtration (A Review of ASHRAE Standards Related to Building Air Quality)
    Carrier Engineering Newsletter Volume 5, Issue 1 Meeting IAQ Needs with Enhanced Filtration (A Review of ASHRAE Standards Related to Building Air Quality) Achieving balance among desired goals for indoor air quality (IAQ), energy consumption, and occupant comfort within the built environment is challenging. The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) endeavors to achieve this through guidelines and standards focused on advancing building science as it relates to environmental quality. This article will review the commonly used design guides found in ANSI/ASHRAE Standard 62.1, “Ventilation for Acceptable Indoor Air Quality.”1 The current form of ANSI/ASHRAE Standard 62.1 employs two mechanical ventilation procedures to provide acceptable IAQ in buildings: the Ventilation Rate Procedure and the Indoor Air Quality Procedure. While the Ventilation Rate Procedure provides only a dilution solution for the control of typical offending contaminants for a specified occupancy, the Indoor Air Quality Procedure provides a directed approach by reducing and controlling the concentrations of selected air contaminants of concern through both dilution and enhanced air cleaning. Rather than relying only on diluting the concentration of contaminants with outdoor air, designing with enhanced filtration of both recirculated and ventilation outdoor air can improve IAQ and result in the protection of the occupied space. This newsletter will focus on the application of enhanced particle, gas-phase and biological filtration for compliance with Standard 62.1. An outline of the design aspects to consider will be reviewed, with the focus on achieving acceptable levels of contaminants of concern within the occupied space while considering the desire to meet high-performance building standards.
    [Show full text]