Agilent Infinitylab LC/MSD Series and 6100 Series LC/MS

Total Page:16

File Type:pdf, Size:1020Kb

Agilent Infinitylab LC/MSD Series and 6100 Series LC/MS Agilent InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts Guide Notices © Agilent Technologies, Inc. 2017 Warranty Safety Notices No part of this manual may be reproduced The material contained in this docu- in any form or by any means (including ment is provided “as is,” and is sub- electronic storage and retrieval or transla- ject to being changed, without notice, CAUTION tion into a foreign language) without prior in future editions. Further, to the max- agreement and written consent from Agi- imum extent permitted by applicable A CAUTION notice denotes a haz- lent Technologies, Inc. as governed by law, Agilent disclaims all warranties, ard. It calls attention to an operat- United States and international copyright either express or implied, with regard ing procedure, practice, or the like laws. to this manual and any information contained herein, including but not that, if not correctly performed or Manual Part Number limited to the implied warranties of adhered to, could result in damage G1960-90104 merchantability and fitness for a par- to the product or loss of important ticular purpose. Agilent shall not be data. Do not proceed beyond a Edition liable for errors or for incidental or consequential damages in connection CAUTION notice until the indi- Revision A, May 2017 with the furnishing, use, or perfor- cated conditions are fully under- Agilent Technologies, Inc. mance of this document or of any stood and met. 5301 Stevens Creek Blvd. information contained herein. Should Santa Clara, CA 95051 Agilent and the user have a separate written agreement with warranty terms covering the material in this WARNING Software Revision document that conflict with these This guide is valid for the C.01.07 SR3 or terms, the warranty terms in the sep- A WARNING notice denotes a later revision of the Agilent OpenLAB CDS arate agreement shall control. hazard. It calls attention to an ChemStation Edition software for the Infini- operating procedure, practice, or tyLab LC/MSD Series and 6100 Series Technology Licenses the like that, if not correctly per- LC/MS until superseded. The hardware and/or software described in formed or adhered to, could result this document are furnished under a in personal injury or death. Do not license and may be used or copied only in accordance with the terms of such license. proceed beyond a WARNING notice until the indicated condi- Restricted Rights Legend tions are fully understood and U.S. Government Restricted Rights. Soft- met. ware and technical data rights granted to the federal government include only those rights customarily provided to end user cus- tomers. Agilent provides this customary commercial license in Software and techni- cal data pursuant to FAR 12.211 (Technical Data) and 12.212 (Computer Software) and, for the Department of Defense, DFARS 252.227-7015 (Technical Data - Commercial Items) and DFARS 227.7202-3 (Rights in Commercial Computer Software or Com- puter Software Documentation). Agilent InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts In This Guide... The Concepts Guide presents an overview of the InfinityLab LC/MSD Series and 6100 Series LC/MS mass selective detector, to help you understand how the hardware and software work. 1 Overview of Hardware and Software Learn how the hardware works in the InfinityLab LC/MSD Series and 6100 Series LC/MS instrument, and get a brief introduction to the OpenLAB CDS ChemStation Edition program. 2 Instrument Preparation Learn the concepts you need to prepare the LC and column for an analysis, and to tune the MS. 3 Data Acquisition Learn about setting up methods and running samples. 4 Data Analysis Learn the concepts you need for qualitative and quantitative data analysis with the ChemStation Edition program. 5 Reports Learn about predefined results reports and about setting up custom reports. 6 Verification of Performance Learn the concepts for Operational Qualification/ Performance Verification (OQ/PV) and system verification with the ChemStation Edition program. 7 Maintenance and Troubleshooting Learn about tools that are proved in the ChemStation Edition program to help you maintain your system and diagnose and fix problems. Agilent InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts Guide 3 This page intentionally left blank. 4 Agilent InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts Content 1 Overview of Hardware and Software 9 How the Agilent mass selective detectors work 10 Overview 10 Details 11 Types of data you can acquire 15 Scan versus selected ion monitoring (SIM) 15 Generation of fragment ions: low versus high fragmentor 16 Positive versus negative ions 18 Multiple signal acquisition 19 Ion sources 21 Electrospray ionization (ESI) 21 Agilent Jet Stream 25 Atmospheric pressure chemical ionization (APCI) 27 Atmospheric pressure photoionization (APPI) 29 Multimode ionization (MMI) 30 Introduction to the ChemStation Edition program 31 Overview 31 Reviewing data remotely 33 2 Instrument Preparation 35 Preparation of the LC system 36 Purpose 36 Summary of procedures 36 Setting parameters for LC modules 38 Column conditioning and equilibration 39 Monitoring the stability of flow and pressure 41 Preparation of the MS – tuning 42 Overview 42 Agilent InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts Guide 5 Contents Ways to tune 44 When to tune – Check Tune 45 Autotune 47 Manual tuning 49 Tune reports 51 Gain calibration 52 3 Data Acquisition 55 Working with methods 56 Method and Run Control View 56 Loading, editing, saving and printing methods 58 More on editing methods 59 Running samples 62 Running a single sample 63 Running a sequence 64 Flow injection analysis 67 Monitoring analyses 70 Online signal plots 70 Logbooks 71 Instrument shutdown 72 4 Data Analysis 73 The Data Analysis View 74 Loading and manipulating chromatograms 76 Loading signals 77 Removing signals from the chromatogram display 81 Changing how chromatograms are displayed 81 Working with spectra 83 Displaying spectra 84 Peak purity 85 Performing quantification 86 6 Agilent InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts Guide Contents Integrating peaks 86 Calibration 88 Data review and sequence reprocessing 90 The Navigation Table 90 Batch review 91 5 Reports 93 Using predefined reports 94 Generating reports 94 Report styles 95 Defining custom reports 96 Summary of process 96 Example report templates 96 The Report Layout View 97 6 Verification of Performance 99 The Verification (OQ/PV) View 100 Instrument verification 101 Setting up and running instrument verification 102 Available OQ/PV tests 104 Verification logbook 105 System verification 106 Overview 106 Setting up and running system verification 107 7 Maintenance and Troubleshooting 109 The Diagnosis View 110 Overview 110 Instrument panel 111 Logbooks 113 Maintenance 114 Agilent InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts Guide 7 Contents Early maintenance feedback 114 Maintenance logbook 115 Maintenance procedures 115 Venting and pumping down the MS 116 Diagnosing and fixing problems 117 Symptoms and causes 117 Diagnostic tests for the MS 118 Fixing problems 120 8 Agilent InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts Guide InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts Guide 1 Overview of Hardware and Software How the Agilent mass selective detectors work 10 Overview 10 Details 11 Types of data you can acquire 15 Scan versus selected ion monitoring (SIM) 15 Generation of fragment ions: low versus high fragmentor 16 Positive versus negative ions 18 Multiple signal acquisition 19 Ion sources 21 Electrospray ionization (ESI) 21 Atmospheric pressure chemical ionization (APCI) 27 Atmospheric pressure photoionization (APPI) 29 Multimode ionization (MMI) 30 Introduction to the ChemStation Edition program 31 Overview 31 Reviewing data remotely 33 This chapter provides an overview of the hardware and ChemStation Edition program that comprises the InfinityLab LC/MSD Series and 6100 Series LC/MS systems. The InfinityLab LC/MSD Series consists of two models: LC/MSD XT and LC/MSD. The 6100 Series LC/MS family consists of three models: 6120B, 6130B, and 6150B. 9 1 Overview of Hardware and Software How the Agilent mass selective detectors work How the Agilent mass selective detectors work Overview Mass selective detectors (MSD) analyze ions moving through a vacuum to produce mass spectra. Mass spectra provide valuable information about the molecular weight, structure, identity, quantity, and purity of a sample. MSDs add specificity to both qualitative and quantitative analyses. A quadrupole mass analyzer is Figure 1 shows a diagram of Agilent MSD instrument. The sometimes called a quadrupole ionization of a sample occurs at atmospheric pressure in the ion mass filter or a quadrupole. source that is shown on the left. The Agilent MSDs are compatible with a number of Agilent atmospheric pressure ionization (API) sources. HPLC inlet quadrupole nebulizer capillary mass filter ion optics detector ion source rough split-flow pump turbo pump Figure 1 Block diagram for an Agilent MSD API – atmospheric pressure A common atmospheric sampling interface introduces ions ionization from these ionization sources into the vacuum system of the mass spectrometer. Various ion-optic elements focus and guide the ions through a series of vacuum stages until they reach the quadrupole mass analyzer, which separates the ions. The ions then travel to the detector, where they are recorded as signals. 10 Agilent InfinityLab LC/MSD Series and 6100 Series LC/MS Concepts Guide Overview of Hardware and Software 1 Details Details Figure 2 and Figure 3 show more detailed schematics of the ion paths in an Agilent MSD. After the API source forms ions, the ion-optic elements in the ion transport and focusing region of the system direct the ions toward the quadrupole and the detector. During transit, the ions move from atmospheric pressure (760 torr) at the source to a vacuum in the 10-6 torr range at the quadrupole and detector.
Recommended publications
  • Mass Spectrometer Detectors
    Mass Spectrometer Detectors www.sge.com Ion Detectors for Virtually all Mass Spectrometry Applications Electron multipliers are used in a wide range of applications to Figure 2. Secondary Electron Emission detect and measure small signals of ions, electrons or photons. One of the main applications for an electron multiplier is for 6 the detection of ions in a mass spectrometer. ACTIVE FILM Multipliers manufactured by ETP ( a division of SGE Group 5 of Companies) are the result of 15 years experience in 4 supplying high performance electron multipliers for use in mass spectrometry applications. The performance of this 3 unique type of ion detector has seen it become widely used in almost all fields of mass spectrometry (including ICP-MS, 2 GC-MS, LC-MS, TOF and SIMS). 1 An electron multiplier is used to detect the presence of ion Secondary Electron Emissions signals emerging from the mass analyser of a mass 0 spectrometer. It is essentially the "eyes" of the instrument (see 0 100 200 300 400 500 Figure 1). The task of the electron multiplier is to detect Incident Electron Energy (eV) every ion of the selected mass passed by the mass filter. How The average number of secondary electrons emitted from the efficiently the electron multiplier carries out this task surface of an ETP electron multiplier plotted against the represents a potentially limiting factor on the overall system energy of the incident primary electron. sensitivity. Consequently the performance of the electron multiplier can have a major influence on the overall (often referred to as a channel electron multiplier or CEM).
    [Show full text]
  • Microchannel Plate Detectors
    Reprinted from Nuclear Instruments and Methods, Vol. 162, 1979, pages 587 to 601 MICROCHANNEL PLATE DETECTORS JOSEPH LADISLAS WIZA 1. Introduction typical. Originally developed as an amplification element for A microchannel plate (MCP) is an array of 104-107 image intensification devices, MCPs have direct sensitivity miniature electron multipliers oriented parallel to one to charged particles and energetic photons which has another (fig. 1); typical channel diameters are in the range extended their usefulness to such diverse fields as X-ray1) 10-100 µm and have length to diameter ratios (α) between and E.U.V.2) astronomy, e-beam fusion studies3) and of 40 and 100. Channel axes are typically normal to, or biased course, nuclear science, where to date most applications at a small angle (~8°) to the MCP input surface. The have capitalized on the superior MCP time resolution channel matrix is usually fabricated from a lead glass, characteristics4-6). treated in such a way as to optimize the secondary emission The MCP is the result of a fortuitous convergence of characteristics of each channel and to render the channel technologies. The continuous dynode electron multiplier walls semiconducting so as to allow charge replenishment was suggested by Farnsworth7) in 1930. Actual from an external voltage source. Thus each channel can be implementation, however, was delayed until the 1960s considered to be a continuous dynode structure which acts when experimental work by Oschepkov et al.8) from the as its own dynode resistor chain. Parallel electrical contact USSR, Goodrich and Wiley9) at the Bendix Research to each channel is provided by the deposition of a metallic Laboratories in the USA, and Adams and Manley10-11) at coating, usually Nichrome or Inconel, on the front and rear the Mullard Research Laboratories in the U.K.
    [Show full text]
  • Characterization of Morphological and Chemical Properties of Scandium Containing
    Characterization of Morphological and Chemical Properties of Scandium Containing Cathode Materials A dissertation presented to the faculty of the College of Arts and Sciences of Ohio University In partial fulfillment of the requirements for the degree Doctor of Philosophy Michael V. Mroz May 2020 © 2020 Michael V. Mroz. All Rights Reserved. 2 This dissertation titled Characterization of Morphological and Chemical Properties of Scandium Containing Cathode Materials by MICHAEL V. MROZ has been approved for the Department of Physics and Astronomy and the College of Arts and Sciences by Martin E. Kordesch Professor of Physics and Astronomy Florenz Plassmann Dean, College of Arts and Sciences 3 ABSTRACT MROZ, MICHAEL V., Ph.D., May 2020, Physics and Astronomy Characterization of Morphological and Chemical Properties of Scandium Containing Cathode Materials Director of Dissertation: Martin E. Kordesch Understanding thermionic cathodes is crucial for the future development of communication technologies operating at the terahertz frequency. Model cathode systems were characterized using multiple experimental techniques. These included Low Energy Electron Microscopy, X-Ray Photoemission Spectroscopy, and Auger Electron Spectroscopy. This was done to determine the mechanisms by which tungsten, barium, scandium, and oxygen may combine in order to achieve high current densities via thermionic emission. Barium and scandium films are found to dewet from the tungsten surfaces studied, and not diffuse out from bulk sources. The dewetted droplets were found to contribute the most to thermal emission. Barium oxide and scandium oxide are also found to react desorb from the emitting surface at lower temperatures then the metals themselves. The function of scandium in scandate cathodes was determined to act as an inhibitor to oxide formation.
    [Show full text]
  • Modern Mass Spectrometry
    Modern Mass Spectrometry MacMillan Group Meeting 2005 Sandra Lee Key References: E. Uggerud, S. Petrie, D. K. Bohme, F. Turecek, D. Schröder, H. Schwarz, D. Plattner, T. Wyttenbach, M. T. Bowers, P. B. Armentrout, S. A. Truger, T. Junker, G. Suizdak, Mark Brönstrup. Topics in Current Chemistry: Modern Mass Spectroscopy, pp. 1-302, 225. Springer-Verlag, Berlin, 2003. Current Topics in Organic Chemistry 2003, 15, 1503-1624 1 The Basics of Mass Spectroscopy ! Purpose Mass spectrometers use the difference in mass-to-charge ratio (m/z) of ionized atoms or molecules to separate them. Therefore, mass spectroscopy allows quantitation of atoms or molecules and provides structural information by the identification of distinctive fragmentation patterns. The general operation of a mass spectrometer is: "1. " create gas-phase ions "2. " separate the ions in space or time based on their mass-to-charge ratio "3. " measure the quantity of ions of each mass-to-charge ratio Ionization sources ! Instrumentation Chemical Ionisation (CI) Atmospheric Pressure CI!(APCI) Electron Impact!(EI) Electrospray Ionization!(ESI) SORTING DETECTION IONIZATION OF IONS OF IONS Fast Atom Bombardment (FAB) Field Desorption/Field Ionisation (FD/FI) Matrix Assisted Laser Desorption gaseous mass ion Ionisation!(MALDI) ion source analyzer transducer Thermospray Ionisation (TI) Analyzers quadrupoles vacuum signal Time-of-Flight (TOF) pump processor magnetic sectors 10-5– 10-8 torr Fourier transform and quadrupole ion traps inlet Detectors mass electron multiplier spectrum Faraday cup Ionization Sources: Classical Methods ! Electron Impact Ionization A beam of electrons passes through a gas-phase sample and collides with neutral analyte molcules (M) to produce a positively charged ion or a fragment ion.
    [Show full text]
  • Joseph Ladislas Wiza, Microchannel Plate Detectors
    Reprinted from Nuclear Instruments and Methods, Vol. 162, 1979, pages 587 to 601 MICROCHANNEL PLATE DETECTORS JOSEPH LADISLAS WIZA 1. Introduction only by the channel dimensions and spacings; 12 mm diameter channels with 15 mm center-to-center spacings are A microchannel plate (MCP) is an array of 104-107 typical. miniature electron multipliers oriented parallel to one Originally developed as an amplification element for another (fig. 1); typical channel diameters are in the range image intensification devices, MCPs have direct sensitivity 10-100 mm and have length to diameter ratios (a) between to charged particles and energetic photons which has 40 and 100. Channel axes are typically normal to, or biased extended their usefulness to such diverse fields as X-ray1) at a small angle (~8°) to the MCP input surface. The and E.U.V.2) astronomy, e-beam fusion studies3) and of channel matrix is usually fabricated from a lead glass, course, nuclear science, where to date most applications treated in such a way as to optimize the secondary emission have capitalized on the superior MCP time resolution characteristics of each channel and to render the channel characteristics4-6). walls semiconducting so as to allow charge replenishment The MCP is the result of a fortuitous convergence of from an external voltage source. Thus each channel can be technologies. The continuous dynode electron multiplier considered to be a continuous dynode structure which acts was suggested by Farnsworth7) in 1930. Actual as its own dynode resistor chain. Parallel electrical contact implementation, however, was delayed until the 1960s to each channel is provided by the deposition of a metallic when experimental work by Oschepkov et al.8) from the coating, usually Nichrome or Inconel, on the front and rear USSR, Goodrich and Wiley9) at the Bendix Research surfaces of the MCP, which then serve as input and output Laboratories in the USA, and Adams and Manley10-11) at electrodes, respectively.
    [Show full text]
  • ELECTRON MULTIPLIERS General Technical Information the Specifications in This Booklet Are Subject to Change
    ELECTRON MULTIPLIERS General Technical Information The specifications in this booklet are subject to change. Please contact ETP for the latest data sheets of any products. PRODUCT DATA 14DM467 500ps MagneTOF® Plus '0SV0DJQH72)£& £ MagneTOF detectorsprovideanexceptionalcombinationof performancecharacteristics.Theyeliminatethecompromises associatedwithotherTOFdetectortechnologies. Thehighperformanceversion,14DM467,typicallyachieves singleionpulsewidthsof<500psFWHM. Specialattentionhasbeengiventominimizingjittersothat pulsesfrommultipleioneventshavenearlythesamewidthas singleionevents. 6SHFLILFDWLRQV ModelNumber 14DM467Rev.H Mechanicalenvelopesize(nominal) 45X52X96mm(notincludingmountingtabs) Inputaperturesize(nominal) 15X33mm <0.55nsMeasuredatdetectoroutputwith3GHz Singleionpulsewidth(FWHM) oscilloscope Ringaftermainpulse(typical) 2%measuredatdetectoroutputwith3GHzoscilloscope Maximumsustainedlinearoutputcurrent 6μAfordispersedorspatiallyconcentratedionbeams Maximumlinearpulseheight 2.5Voltintoa50Ohmload Maximumdarkcounts@2600V <50perminute Recoverytimeafterlargepulse Negligible Maximumoperatingpressure 10Ͳ4Torr Protectfromdustinoriginalpackagingorinan Long/shorttermstoragerequirements appropriatedesiccator MaximumcurrentdrawfromHVpower 0.5mA supplyatthemaximumoperatingVoltage Ambienttemperaturerangefornormal 15to28°C(59to82°F) operation Ambienttemperaturerangeforoptimum 19to23°C(66to73°F) operation Typicalgainwhenmultiplierisnew 1E6@~1950V Operatingvoltagerange* ~Ͳ1800V(initial)toͲ3400Vmaximum(aged). *Note:OperatinganewdetectoratendͲofͲlife(maximum)voltagePD\UHVXOWindamageWRWKHGHWHFWRU
    [Show full text]
  • Photomultiplier Tube Basics Photomultiplier Tube Basics
    Photomultiplier tube basics Photomultiplier tube basics Still setting the standard 8 Figures of merit 18 Single-electron resolution (SER) 18 Construction & operating principle 8 Signal-to-noise ratio 18 The photocathode 9 Timing 18 Quantum efficiency (%) 9 Response pulse width 18 Cathode radiant sensitivity (mA/W) 9 Rise time 18 Spectral response 9 Transit-time and transit-time differences 19 Transit-time spread, time resolution 19 Collection efficiency 11 Very-fast tubes 11 Linearity 19 Fast tubes 11 External factors affecting linearity 19 General-purpose tubes 11 Internal factors affecting linearity 20 Tubes optimized for PHR 12 Linearity measurement 21 Measuring collection efficiency 12 Stability 21 The electron multiplier 12 Long-term drift 21 Secondary emitting dynode coatings 13 Short-term shift (or count rate stability) 22 Voltage dividers 13 Gain 1 Supply and voltage dividers 23 Anode collection space 1 Applying the voltage 23 Anode sensitivity 1 Voltage dividers 2 Specifications and testing 1 Anode resistor 2 Maximum voltage ratings 1 Gain adjustment 2 Anode dark current & dark noise 1 Magnetic fields 2 Ohmic leakage 1 Thermionic emission 1 Magnetic shielding 27 Field emission 1 Environmental considerations 28 Radioactivity 1 Temperature 28 PMT without scintillator 1 Atmosphere 29 PMT with scintillator 1 Mechanical stress 29 Cathode excitation 1 Radiation 29 Dark current values on test tickets 1 Reference 30 Afterpulses 17 www.photonis.com Still setting Construction the standard & operating principle A photomultiplier tube is
    [Show full text]
  • Quadrupole Ion Traps (QIT) • Time-Of-Flight (TOF) Mass Analyzers
    Updated: 17 November 2014 Print version CEE 772: Instrumental Methods in Environmental Analysis Lecture #20 Rosa Yu & Dave Reckhow Mass Spectrometry and Instrumentation CEE 772 #20 1 Content • A brief introduction to mass spectrometry • Mass spectrometry instrumentation – Important MS instrument performance factors – Types of mass spectrometers: • (Triple) Quadrupole Mass Spectrometer • Quadrupole Ion Traps (QIT) • Time-of-flight (TOF) Mass Analyzers Ion source ➡ Mass filtration/separation ➡ Detection CEE 772 #20 2 Content • A brief introduction to mass spectrometry • Mass spectrometry instrumentation – Important MS instrument performance factors – Types of mass spectrometers: • (Triple) Quadrupole Mass Spectrometer • Quadrupole Ion Traps (QIT) • Time-of-flight (TOF) Mass Analyzers Ion source ➡ Mass filtration/separation ➡ Detection CEE 772 #20 3 Mass Spectrometry Introduction Ion Formation Mass Analysis Detection • Ionization: • Electrospray Ionization • Electron Impact/Chemical Ionization • MALDI (matrix assisted laser desorption ionization) • Mass Analysis/Separation: • Use electric and magnetic fields to apply a force on charged particles to control the trajectories of ions • Detection: • Electron multiplier CEE 772 #20 4 The effect of electromagnetic fields on ions • The relationship between force, mass, and the applied fields can be summarized in Newton's second law and the Lorentz force law. 1. Newton's second law: F = ma the force causes an acceleration that is MASS dependent 2. Lorentz force law: F = e(E + vB) the applied force
    [Show full text]
  • Mass Spectrometry
    Mass spectrometry Dr. Kevin R. Tucker What is mass spectrometry? A versatile analytical technique used to determine the Dichloromethane CH2Cl2 12 1 35 composition of chemical C H2 Cl2 = 84 13 1 35 C H2 Cl2 = 85 samples either at the atomic or 12 1 35 37 C H2 Cl Cl = 86 13 1 35 37 molecular level. C H2 Cl Cl = 87 12 1 37 Ionic forms of samples are C H2 Cl2 = 88 separated according to differences in component mass- to-charge (m/z) ratio. Signals from each different isotopic composition Isotope % Natural Abundance m/z Isotopes usually stable 12C 98.93 Keep in mind charge, z, in (+1, +2, 13C 1.07 +3, etc.); not knowing z can result 35Cl 75.77 Textbook value is in mass errors by a factor of 2, 3, a weighted average 37 etc. Cl 24.23 } Cl At. wt. = 35.453 Basic instrumental setup for mass spectrometry Fig. 20-11 Molecular mass spectrometry Chapter 20 Generating ions for molecular mass spectrometry Two major classes Gas phase: Sample vaporized then ionized Desorption: Solid or liquid sample is directly converted into gas phase ions * * * * * Molecular mass spec ion source considerations Gas-phase Thermally stable compounds with bp less than 500oC Limited to masses less than 1000 Da (atomic mass unit; amu) Desorption Does not require volatilization Analytes up to 100,000+ Da Hard vs. soft sources Hard sources leave molecule in excited energy states which relax via bond cleavage. Give “daughter ion” fragments at lower m/z. Soft sources minimize fragmentation. Resulting spectra has fewer peaks.
    [Show full text]
  • Electron Transfer Dissociation and Collision-Induced Dissociation
    ELECTRON TRANSFER DISSOCIATION AND COLLISION-INDUCED DISSOCIATION MASS SPECTROMETRY OF METALLATED OLIGOSACCHARIDES by RANELLE MARIE SCHALLER-DUKE CAROLYN J. CASSADY, COMMITTEE CHAIR JOHN B. VINCENT SHANE C. STREET ŁUKASZ CIEŚLA SHANLIN PAN A DISSERTATION Submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the Department of Chemistry and Biochemistry in the Graduate School of The University of Alabama TUSCALOOSA, ALABAMA 2019 Copyright Ranelle Marie Schaller-Duke 2019 ALL RIGHTS RESERVED ABSTRACT Investigations of metallated glycans through tandem mass spectrometry (MS/MS) can further the field of glycomics, the sequencing of the human glycome. The field is hindered by the lack of an analytical technique that can determine all the stereo-diverse features of carbohydrates. In this dissertation, electron transfer dissociation (ETD) and collision-induced dissociation (CID) are utilized with metal-adducted oligosaccharides to explore the potential of these techniques to sequence glycans. The resulting mass spectra provide significant insight and information about the structure of oligosaccharides and how to distinguish between these complicated isomeric species. Using univalent, divalent, and trivalent transition metal adducts is valuable to glycan analysis. The ETD process requires multiply charged ions, which do not form via protonation for neutral glycans, and CID of protonated glycans produces uninformative glycosidic bond cleavage. The univalent and trivalent metals investigated did not produce ions sufficient for ETD studies, but CID of the trivalent metal adducts showed significant fragmentation. Dissociation of [M + Met]2+ from the divalent metals formed various fragment ions with ETD producing more cross-ring and internal cleavages, which are necessary for structural analysis.
    [Show full text]
  • LTQ Series Hardware Manual
    LTQ Series Hardware Manual 97055-97072 Revision D September 2015 © 2015 Thermo Fisher Scientific Inc. All rights reserved. Automatic Gain Control, Foundation, Ion Max-S, LTQ XL, Orbitrap Elite, Orbitrap Velos Pro, Velos, Velos Pro, and ZoomScan are trademarks; Unity is a registered service mark; and Accela, Ion Max, LTQ, LXQ, Orbitrap, Thermo Scientific, and Xcalibur are registered trademarks of Thermo Fisher Scientific Inc. in the United States. The following are registered trademarks in the United States and other countries: Microsoft and Windows are registered trademarks of Microsoft Corporation. Vespel is a registered trademark of E.I. du Pont de Nemours &Co. The following are registered trademarks in the United States and possibly other countries: Agilent is a registered trademark of Agilent Technologies, Inc. Convectron is a registered trademark of Helix Technology Corporation. Liquinox is a registered trademark of Alconox, Inc. MICRO-MESH is a registered trademark of Micro-Surface Finishing Products, Inc. Upchurch Scientific is a registered trademark of IDEX Health & Science LLC. Viton is a registered trademark of DuPont Performance Elastomers LLC. Waters is a registered trademark of Waters Corporation. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Thermo Fisher Scientific Inc. provides this document to its customers with a product purchase to use in the product operation. This document is copyright protected and any reproduction of the whole or any part of this document is strictly prohibited, except with the written authorization of Thermo Fisher Scientific Inc. The contents of this document are subject to change without notice. All technical information in this document is for reference purposes only.
    [Show full text]
  • Mass Spectrometry 3
    PLATINblue MSQ Plus Hardware Guide V6950A UHPLC/HPLC Mass spectrometry 3 Content Preface . 8 Safety . 8 Fuses . 8 Lab regulations . 8 LC Solvents and Mobile Phase Additives . 8 LC Solvents . 8 Protective measures . 9 Safety precautions . 9 Solvent and Gas Purity Requirements . 11 Contacting Us . 11 To contact Technical Support or Customer Service for ordering information . 11 To suggest changes to documentation or to Help . 11 Introduction . 12 Overview . 12 Ion Polarity Modes . 13 Ionization Techniques . 14 Electrospray Ionization (ESI) . 14 Ion Desolvation Mechanism . 14 Spectral Characteristics . 15 Atmospheric Pressure Chemical Ionization (APCI) . 16 Ion Generation Mechanism . 16 Spectral Characteristics . 18 Scan Types . 18 Full Scan . 18 Selected Ion Monitoring (SIM) . 18 Data Types . 19 Profile Data Type . 19 Centroid Data Type . 20 MCA Data Type . 21 Functional Description. 22 Liquid Chromatograph . 23 To open the Instrument Configuration application . 23 Reference Inlet System . 25 Mass Detector . 27 Front Panel Status Indicator . 28 Rear Panel Controls and Connections . 29 Connection Between LC and Mass Detector . 31 API Sources . 31 V6950A 4 Electrospray Ionization (ESI) . 31 Atmospheric Pressure Chemical Ionization (APCI) . 33 RF/dc Prefilter . 34 Mass Analyzer . 35 RF and DC Fields Applied to the Quadrupoles . 35 Mass Analysis . 36 Ion Detection System . 37 Vacuum System . 39 Vacuum Manifold . 40 Turbomolecular Pump . 40 Forepump . 41 Pirani Gauge . 41 Vent Valve . 41 Inlet Gas Hardware . 42 Cone Wash System . 45 Data System . 46 Computer Hardware . 46 Xcalibur Software . 47 MSQ Plus Mass Detector Server . 49 Tune Window . 50 Title Bar . 51 Menu Bar . 51 Toolbar . 51 Comms Indicator . 51 Scan Events Table .
    [Show full text]