August 2021 Countries Supported by the SolarEdge Inverters
The SolarEdge inverters can be used in many different countries. This document details countries where SolarEdge approves installation of its inverters. Installation should always be done in compliance with local regulations, and in case of a conflict between local regulations and this document, local regulations apply.
Summary The SolarEdge inverters may be installed in the following countries. Unless stated otherwise, the approval refers to low voltage installations. For medium voltage installations, please contact SolarEdge support. Please refer to the country details below for more information, as in some countries not all grids are supported or not all inverter models are supported. In supported countries, connection of supported inverters to non-supported grids is permitted through a transformer, if the secondary connection (transformer connection to the inverter) is identical to a supported grid.
NOTE Transformer procurement, installation, maintenance and support are the responsibility of the installer. Damage to the inverter due to incorrect transformer installation or use of a transformer that is incompatible with the SolarEdge system will render the SolarEdge warranty invalid.
NOTE Prior to purchasing a StorEdge system verify battery availablity and service in the country. Availability of SolarEdge StorEdge products does not guarantee battery availabllity.
A country listed in bold indicates that StorEdge Inverters with backup are approved for installation in that country.
NOTE The StorEdge Inverter must be connected Line to Neutral (and not Line to Line).
Argentina Croatia Hungary Morocco Sweden
Armenia Curacao India Namibia Switzerland
Aruba Cyprus Indonesia Netherlands Tahiti
Australia Czech Republic Ireland New Zealand Taiwan
Austria Denmark Israel Norway Thailand
Bahrain Dominican Republic Italy Panama Turkey
Barbados Dubai Jamaica Peru Ukraine
Belarus Ecuador Japan Philippines United Kingdom
Belgium El Salvador Jordan Poland Uruguay
Bermuda Estonia Kenya Portugal USA
Botswana Finland Korea Romania Vietnam
Brazil France Kuwait Seychelles Zimbabwe
Bulgaria Georgia Latvia Singapore
Canada Germany Lithuania Slovakia
Cape Verde Ghana Luxembourg Slovenia
Cayman Islands Greece Macau South Africa
Chile Grenada Malaysia Spain
China Guadeloupe Malta Sri Lanka
Colombia Guatemala Mauritius St. Lucia
Costa Rica Hong Kong Mexico St. Vincent
August 2021
For installation in countries or with grids not detailed in this document, contact SolarEdge support: [email protected] * Using the StorEdge Inverter with backup requires an External Disconnection Unit. For additional information refer to: https://www.solaredge.com/sites/default/files/se_storedge_inverter_for_europe_datasheet.pdf
Detailed Information per Country The table below details for each of the above countries:
1. Supported inverters: which SolarEdge inverters may be used in the country
2. Inverter country setting: to what country setting the inverter should be configured in order to comply with the local grid requirements. Some countries have a submenu that should be used; sub-entries are indicated with the following symbol: ->
3. Frequency: the nominal inverter AC frequency for the corresponding country setting
4. Comments: additional information about the inverter and grid support
3
Supported inverters Inverter country Frequency Comments setting Argentina SE4K, SE5K, SE6K, SE7K, Israel -> Israel 50Hz Commercial setting for systems >50kW SE8K, SE9K, SE10K, SE12.5K, Israel -> Israel – SE15K, SE16K, SE17K, SE25K, Commercial SE27.6K, SE30K, SE33.3K Aruba SE3000A-US – SE11400A-US, Caribbean -> Aruba 60Hz Available from CPU v2.07xx SE3000H-US – SE10000H-US Can be connected to the following grid: 127/220V (L-L connection) SE3800A-US limited to 3.5kW AC SE6000A-US limited to 5.5kW AC SE11400A-US approved only for installations with no LVRT (low voltage ride through) requirement; if required – contact SolarEdge support
SE9KUS, SE14.4KUS, Caribbean -> Aruba 60Hz Available from CPU v2.07xx SE17.3KUS, SE43.2KUS Can be connected to the following grid: 127/220V
Armenia
SE2200, SE3000, SE3500, SE4000, Germany 50Hz SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K SE15K, SE16K, SE17K, Germany -> 50Hz These inverters are approved for connection to the SE25K, SE27.6K, SE30K, Germany medium voltage grid according to the BDEW SE33.3K Germany -> standard; use Germany MVGC Germany MVGC * StorEdge Inverter without Germany 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Australia SE2200, SE3000, SE3500, SE4000, Australia -> Australia 50Hz Use Queensland setting when QLD wider voltage SE4600, SE5000, SE6000, SE7300; Australia -> range is required; available from CPU v2.0496 SE2500H, SE3000H, SE3500H, Queensland Victoria setting available from CPU v3.19xx SE4000H, SE4600H, SE5000H, Australia Western Power available with SetApp SE6000H, SE8000H, SE8250H, Australia -> Australia SE10000H; Western Power enabled inverters from CPU v4.9.xx SE5K, SE7K, SE8.25K, SE9K, SE10K, SE12.5K, SE15K, Australia VIC SE16K, SE17K, SE25K, SE27.6K, Australia SE30K, SE33K, SE50K, SE82.8K, Essential Energy SE100K Australia Ausgrid
4
Supported inverters Inverter country Frequency Comments setting SE66.6K, SE80K, SE100K, SE120K Australia 50Hz * Australia VIC, Australia Essential Energy, Endeavour Australia Ausgrid, Australia Endeavour Energy Energy, Australia SAPN, Australia Horizon Australia SAPN Power, Australia Evoenergy are available with
Australia SetApp enabled inverters from CPU v4.11xx Horizon Power Australia Evoenergy *
Australia - > Australia 480
* StorEdge Inverter without Australia -> Australia 50Hz * Requires StorEdge-compatible inverter backup power: Australia -> Available from CPU v3.18xx SE2200H, SE3000H, SE3500H, Queensland SE4000H, SE4600H, SE5000H, Australia -> Victoria SE6000H, SE7300H, SE3500H Australia -> Australia * AC Coupled Inverters: SE3000H, Australia -> SE5000H Queensland Australia -> Victoria
Austria SE2200H, SE3000H, SE3500H, Austria (Österreich) 50Hz 400V grid connection acc. to TOR Erzeuger Typ A SE3680H, SE3K-RWB, SE4K-RWB, SE5K- RWB SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE66.6K, SE82.8K, SE90K, SE100K, SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS SE2200H, SE3000H, SE3500H, Austria (Österreich) 50Hz 400V grid connection acc. to TOR Erzeuger Typ A SE3680H, SE3K-RWB, SE4K-RWB, SE5K-RWB StorEdge compatible Inverter (AC- or DC-coupled) SE5K-RWS, SE7K-RWS, SE8K-RWS, without backup power SE10K-RWS
SE25K, SE27.6K, SE30K*, SE33.3K*, Austria (Österreich) 50Hz 400V grid connection, acc. to TOR Erzeuger Typ B SE55K, SE66.6K*, SE82.8K, SE90K*, (*remark: certification pending) SE100K + Site specific adjustment of parameters acc. to grid-operator
SE40K, SE120K Austria 480V 50Hz 480V grid connection, acc. to TOR Erzeuger Typ B (Österreich) (remark: certification pending) + Site specific adjustment of parameters acc. to grid-operator
5
Supported inverters Inverter country Frequency Comments setting Bahrain SE2200, SE3000, SE3500, SE4000, Hungary 50Hz Available from CPU v2.09xx / v3.12xx SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K,SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE50K, SE55K, SE82.8K * StorEdge Inverter without Hungary 50Hz * Requires StorEdge-compatible inverter backup power: SE2200, SE3000, SE3500, SE4000, SE5000, SE6000, SE3500 AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Barbados SE3000A-US – SE11400A-US, Caribbean -> 50Hz Available from CPU v2.0496 SE3000H-US – SE10000H-US Barbados 230V No N Can be connected to the following grids: 115/230V split phase or 3-wire (L-L connection) 230/400V WYE (L-N connection)
SE9KUS, SE14.4KUS, Caribbean -> 50Hz Available from CPU v2.09xx / v3.12xx 17.3KUS, SE43.2KUS Barbados 115V Can be connected to the following grid: 115/200V WYE SE10KUS, SE20KUS, SE30KUS, Caribbean -> 50Hz Supported in inverters shipped from Jan. 10 2014 SE33.3KUS, SE40KUS, SE66.6KUS, Barbados 230V (No that have DSP1 v1.13.321; for other inverters SE100KUS N) contact SolarEdge support. Can be connected to the following grid: 230/400V WYE SE20kUS limited to 16.5kW AC SE30KUS, SE33.3KUS limited to 27.6kW AC SE66.6KUS limited to 55kW AC SE100KUS limited to 82.8kW AC Belarus SE2200, SE3000, SE3500, SE4000, Europe EN50438 50Hz Available from CPU v3.16xx SE5000, SE6000, SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K * StorEdge Inverter without Europe EN50438 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H,
6
Supported inverters Inverter country Frequency Comments setting
SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Belgium SE1000M, SE1500M, SE2000M, Belgium 230/400V 50Hz Refer to the following note for more details about SE2000H, SE2200H, SE3000H, grid compliance: SE3500H, SE3680H, SE4000H, https://www.solaredge.com/sites/default/files/se_t SE5000H, SE6000H; hree_phase_inverters_for_delta_grids.pdf SE3K-RWB, SE4K-RWB, SE5K-RWB SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE50K, SE55K, SE66.6K, SE82.8K, SE90K, SE100K, SE10K-BE SE66.6K, SE80K, SE100K, SE120K Belgium 480V 50Hz These inverters have a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
SE6K, SE7K, SE8K, SE9K, SE10K, Belgium Delta 50Hz Can be connected to the following grid: 220/230V SE12.5K, SE15K, SE16K, SE17K, True Delta SE25K, SE27.6K, SE30K, Inverter AC power is limited; requires inverter SE33.3K; adjustment. For details refer to: SE50K, SE55K, SE66.6K, https://www.solaredge.com/sites/default/files/s SE82.8K, SE90K, SE100K, e_three_phase_inverters_for_delta_grids.pdf) SE10K-BE Available from CPU v3.2167
* StorEdge Inverter without Belgium 50Hz * Requires StorEdge-compatible inverter or backup power: installation of the StorEdge Interface; refer SE2200H, SE3000H, SE3500H, to application note. SE3680H, SE4000H, SE5000H, SE6000H, AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H
StorEdge three phase inverter: SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS Bermuda SE3000A-US – SE11400A-US, USA -> Auto 60Hz Refer to the inverter datasheet for full inverter- SE3000H-US – SE10000H-US USA -> 240V grid compatibility: USA -> 240V No https://www.solaredge.com/sites/default/files/se- Neutral hd-wave-single-phase-inverter-with-setapp- USA -> 208V datasheet-na.pdf USA -> 208V No Neutral SE9KUS, SE14.4KUS, SE17.3KUS, USA -> 208V 60Hz 120/208V WYE grid only SE43.2KUS, SE50KUS SE40KUS, SE66.6KU, SE80KUS, USA -> 277V 60Hz 277/480V WYE grid only SE85KUS, SE100KUS, SE120KUS
7 Botswana
SE2200, SE3000, SE3500, SE4000, South Africa 50Hz SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K; SE50K, SE55K, SE66.6, SE82.8K, SE100K Brazil SE9200H, SE8250H, SE6000H, Can be connected to 380/220Vac and 220/127Vac SE5000H, SE3680H grids. Brazil --> Brazil 60Hz When connected to 220/127Vac grid, must use 2 380/220Vac phases, connecting one phase to neutral point at AC terminal of inverter SE17K, SE21.1K Can be connected to the following grids: SE27.6K, SE33.3K, 380/220Vac SE75K Brazil -> Brazil 220/127Vac; when connected to this grid: 380/220Vac SE17K limited to 9kW AC 60Hz Brazil -> Brazil SE21.1K limited to 11.6kW AC 220/127Vac SE27.6K limited to 15.2kW AC SE33.3K limited to 19.2kW AC SE75k limited to 43.5kW AC SE100K This inverter has a 480/277Vac output voltage and Brazil -> Brazil 60Hz is designed for connection to the medium voltage 480/277Vac grid via a transformer Bulgaria
SE2200, SE3000, SE3500, SE4000, Bulgaria 50Hz SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE66.6K, SE82.8K, SE100K * StorEdge Inverter without Bulgaria 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Canada SE3000A-US-CAN – SE11400A- USA -> Auto 60Hz Refer to the inverter datasheet for full inverter- US-CAN, SE3000H-US – USA -> 240V grid compatibility: SE10000H-US USA -> 240V No https://www.solaredge.com/sites/default/files/se- Neutral hd-wave-single-phase-inverter-with-setapp- USA -> 208V datasheet-na.pdf USA -> 208V No Neutral
8 SE9KUS-CAN, SE14.4KUS, USA -> 208V 60Hz 120/208V WYE grid only SE17.3KUS, SE43.2KUS, SE50KUS SE10KUS-CAN, SE20kUS-CAN, USA -> 277V 60Hz 277/480V WYE grid only SE30KUS, SE33.3KUS, SE40KUS, SE66.6KU, SE80KUS, SE85KUS, SE100KUS, SE120KUS Cape Verde
SE2200, SE3000, SE3500, SE4000, Contact SolarEdge 50Hz SE5000, SE6000 support SE4K, SE5K, SE7K, SE8K, Cape Verde 50Hz Available from CPU version 3.18xx SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K Cayman Islands SE3000A-US – SE11400A-US, Hawaii -> XXX Auto 60Hz Refer to the inverter datasheet for full inverter- SE3000H-US – SE11400H-US Hawaii -> XXX 240V grid compatibility: Hawaii -> XXX 240V https://www.solaredge.com/sites/default/files/se- No Neutral hd-wave-single-phase-inverter-with-setapp- Hawaii -> XXX 208V datasheet-na.pdf Hawaii -> XXX 208V Use Hawaii settings for HECO grid settings No Neutral Molokai and Lanai setting available from CPU XXX = Hawaii / Kauai v2.10xx / v3.14xx / Molokai and Lanai
SE9KUS, SE14.4KUS, Hawaii -> XXX 208V 60Hz 120/208V WYE grid or 208V Delta grid (SE9KUS SE17.3KUS, SE43.2KUS XXX = Hawaii / Kauai delta grid support for inverters with part number / Molokai and Lanai SE9K-US228NNU4) Use Hawaii settings for HECO grid settings Molokai and Lanai setting available from CPU v2.10xx / v3.14xx
SE10KUS, SE20KUS, SE30KUS, Hawaii -> XXX 277V 60Hz 277/480V WYE grid only SE33.3KUS, SE40KUS, XXX = Hawaii / Kauai Use Hawaii settings for HECO grid settings SE66.6KUS, SE100KUS / Molokai and Lanai Molokai and Lanai setting available from CPU v2.10xx / v3.14xx
SE7600A-USS (StorEdge inverter) Hawaii -> XXX Auto 60Hz Use Hawaii settings for HECO grid settings Hawaii -> XXX 240V Available from CPU v3.18xx Hawaii -> XXX 240V No Neutral XXX = Hawaii / Kauai / Molokai and Lanai
Chile
SE4K, SE5K, SE6K, SE7K, SE8K, Chile 50Hz SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE30K, SE33.3K, SE27.6K, SE33.3K, SE82.8K China (exc. Hong Kong and Macau) SE15K, SE16K, SE17K; China 50Hz All systems must be approved by SolarEdge; SE66.6K, SE100K, SE120K contact SolarEdge Support for details
9
Supported inverters Inverter country Frequency Comments setting Colombia
Colombia 60Hz Costa Rica SE3000A-US – SE11400A-US, USA -> Auto 60Hz Refer to the inverter datasheet for full inverter- SE3000H-US- SE10000H-US USA -> 240V grid compatibility: USA -> 240V No https://www.solaredge.com/sites/default/files/se- Neutral hd-wave-single-phase-inverter-with-setapp- USA -> 208V datasheet-na.pdf USA -> 208V No Neutral SE9KUS, SE14.4KUS, SE17.3KUS USA -> 208V 60Hz 120/208V WYE grid only SE43.2KUS, SE50KUS SE10KUS, SE20KUS, SE33.3KUS, USA -> 277V 60Hz 277/480V WYE grid only SE40KUS, SE66.6KU, SE80KUS, SE85KUS, SE100KUS, SE120KUS Croatia SE2200, SE3000, SE3500, SE4000, Croatia 50Hz Available from CPU v2.0496 SE5000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE82.8K * StorEdge Inverter without Croatia 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Curacao SE2200, SE3000, SE3500, SE4000, Caribbean -> 50Hz Available from CPU v2.0637 SE5000, SE2200H, SE3000H, Curacao Can be connected to the following grids: SE3500H, SE3680H, SE4000H, 127/220V WYE (L-L connection) SE5000H 110/220V split phase (L-L connection) 220/380V WYE (L-N connection)
SE4K, SE5K, SE7K, SE8K, Caribbean -> 50Hz Available from CPU v2.0637 SE9K, SE10K, SE12.5K, SE15K, Curacao Can be connected to the following grid: 220/380V SE16K, SE17K, SE25K, WYE SE27.6K, SE30K, SE33.3K Systems 100kW and larger must be approved by SE55K, SE82.8K SolarEdge; contact SolarEdge Support for details Cyprus
SE2200, SE3000, SE3500, SE4000, Cyprus 50Hz SE5000, SE6000; SE2200H, Cyprus 240V SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H;
10
Supported inverters Inverter country Frequency Comments setting
SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K; SE55K, SE82.8K * StorEdge Inverter without Cyprus 50Hz * Requires StorEdge-compatible inverter backup power: Cyprus 240V SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Czech Republic
SE1000M, SE1500M, SE2000M Czech Republic 50Hz SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE8000H, SE10000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K; SE50K, SE55K, SE66.6K, SE82.8K, SE100K * StorEdge Inverter without Czech Republic 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H;
StorEdge three phase inverter:
SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS
Denmark SE1000M, SE1500M ,SE2000M Denmark -> 50Hz Use Residential settings to comply with 16Aac and SE2200, SE3000, SE3500, SE4000, Denmark 6kW limits of residential systems SE5000, SE6000; SE2200H, Denmark -> Use VDE settings for VDE-AR-N-4105 grid SE3000H, SE3500H, SE3680H; Denmark Residen. settings; Available from CPU v2.0496 SE4K, SE5K, SE6K, SE7K, SE8K, Denmark -> SE9K, SE10K, SE12.5K, SE15K, Denmark VDE SE16K, SE17K, SE25K, SE27.6K Denmark -> SE30K, SE33.3K, SE40K; Denmark VDE Res. SE50K, SE55K, SE82.8K * StorEdge Inverter without Denmark -> 50Hz * Requires StorEdge-compatible inverter backup power: Denmark SE2200H, SE3000H, SE3500H, Denmark -> SE4000H, SE5000H, SE6000H, Denmark Residen. SE3500H Denmark -> Denmark VDE
11
Supported inverters Inverter country Frequency Comments setting
AC Coupled Inverter: SE2200H, Denmark -> SE3000H, SE3500H, SE3680H; Denmark VDE Res. SE4000H, SE5000H, SE6000H;
StorEdge three phase inverter: SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS
Dominican Republic SE3000A-US – SE11400A-US, USA -> Auto 60Hz Refer to the inverter datasheet for full inverter- SE3000H-US – SE11400H-US USA -> 240V grid compatibility: USA -> 240V No https://www.solaredge.com/sites/default/files/se- Neutral hd-wave-single-phase-inverter-with-setapp- USA -> 208V datasheet-na.pdf USA -> 208V No Rule 21 setting available from CPU v3.16xx Neutral Rule 21 -> Auto Rule 21 -> 240V Rule 21 -> 240V No Neutral Rule 21 -> 208V Rule 21 -> 208V No Neutral SE9KUS, SE14.4KUS, SE17.3KUS USA -> 208V 60Hz 120/208V WYE grid or 208V Delta grid (SE9KUS SE43.2KUS, SE50KUS Rule 21 -> 208V delta grid support for inverters with part number SE9K-US228NNU4) Rule 21 setting available from CPU v3.16xx SE10KUS, SE20KUS, SE30KUS, USA -> 277V 60Hz 277/480V WYE grid only SE33.3KUS, SE40KUS, SE66.6KU, Rule 21 -> 277V Rule 21 setting available from CPU v3.16xx SE80KUS, SE85KUS, SE100KUS, Puerto Rico 277V Puerto Rico setting available from CPU v3.19xx SE120KUS SE7600A-USS (StorEdge inverter) USA -> Auto 60Hz Available from CPU v3.18xx USA -> 240V Dubai SE2200, SE3000, SE3500, SE4000, Dubai 50Hz Available from CPU v3.18xx SE5000, SE6000; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K
Ecuador
SE1000M, SE1500M, SE2000M; Ecuador 60Hz SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE82.8K
12
Supported inverters Inverter country Frequency Comments setting El Salvador
SE3000A-US – SE11400A-US, USA -> Auto 60Hz SE3000H-US- SE10000H-US USA -> 240V USA -> 240V No Neutral Estonia
SE1000M, SE1500M, SE2000M, Portugal 50Hz SE2200H, SE3000H, SE3500H, SE3680H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K SE55K, SE82.8K * StorEdge Inverter without Portugal 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H StorEdge three phase inverter;
SE5K-RWS, SE7K-RWS,
SE8K-RWS, SE10K-RWS
Finland SE1000M, SE1500M, SE2000M, Finland 50Hz Available from CPU v3.18xx SE4000H, SE5000H, SE6000H, SE8000H, SE10000H;
SE2200H, SE3000H, SE3500H, SE3680H; SE3K, SE4K, SE5K, SE6K SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE50K, SE55K, SE82.8K * StorEdge Inverter without Finland 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE3680H; SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter:
SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H;
StorEdge three phase inverter:
13
Supported inverters Inverter country Frequenc Comments setting y
SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS
France
SE2200, SE3000, SE3500, SE4000, France 50Hz SE5000, SE6000; SE2200H, SE1000M, SE1500M, SE2000M, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H, SE8000H, SE10000H; SE3K-RWB, SE4K-RWB, SE5K- RWB; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K; SE50K, SE55K, SE66.6K, SE80K, SE82.8K, SE90K, SE100K, SE120K SE33.3K, SE40K SE66.6K, SE100K France -> France MV 50Hz Available from CPU v3.2016 These inverters have a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
* StorEdge Inverter without France 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS Germany SE2200H, SE3000H, SE3500H, Germany (Deutschland) 50Hz 400V grid connection acc. to SE3680H, SE4000H, SE5000H, VDE-AR-N 4105:2018-11 SE3K-RWB, SE4K-RWB, SE5K-RWB SE3K, SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE66.6K, SE82.8K, SE90K, SE100K, SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS
14 SE2200H, SE3000H, SE3500H, Germany 50Hz 400V grid connection acc. to VDE-AR-N 4105:2018-11, SE3680H, SE4000H, SE5000H, (Deutschland) SE3K-RWB, SE4K-RWB, StorEdge compatible Inverter (AC- or DC-coupled) SE5K-RWB without backup power SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS SE25K, SE27.6K, SE30K, SE33.3K, Germany MVGC 50Hz 400V grid connection acc. to VDE-AR-N 4110:2018-11 SE55K, SE66K, SE82.8K, SE90K (Deutschland_MV) + Site specific adjustment of parameters acc. to grid- operator SE33.3K, SE40K, SE100K, SE120K Germany 480V 50Hz 480V grid connection acc. to VDE-AR-N 4110:2018-11 (Deutschland + Site specific adjustment of parameters acc. to grid- 480V) operator Ghana SE2200, SE3000, SE3500, SE4000, Ghana 50Hz Available from CPU v3.18xx SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K Georgia SE2200, SE3000, SE3500, SE4000, Europe EN50438 50Hz Available from CPU v3.16xx SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K * StorEdge Inverter without Europe EN50438 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Greece
SE2200, SE3000, SE3500, SE4000, Greece -> Greece 50Hz SE5000, SE6000; SE2200H, Continent SE3000H, SE3500H, SE3680H, Greece -> Greece SE4000H, SE5000H, SE6000H; Islands SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE55K, SE66.6K, SE82.8K, SE100K
* StorEdge Inverter without Greece -> Greece 50Hz * Requires StorEdge-compatible inverter backup power: Continent
15
Supported inverters Inverter country Frequency Comments setting
SE2200H, SE3000H, SE3500H, Greece -> Greece SE4000H, SE5000H, SE6000H, Islands SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Grenada SE3000A-US – SE11400A-US, Grenada 50Hz Available from CPU v3.18xx SE3000H-US – SE10000H-US Can be connected to the following grid: 230/400V WYE (L-N connection) SE9KUS, SE14.4KUS, SE17.3kUS, Grenada 50Hz Available from CPU v3.18xx SE43.2kUS Can be connected to the following grid: 230/400V WYE
SE10KUS – SE20kUS, SE30KUS, Grenada 50Hz Available from CPU v3.18xx SE33.3KUS, SE40KUS, Can be connected to the following grid: 230/400V SE66.6KUS, SE100KUS WYE SE20kUS limited to 16.5kW AC SE30KUS, SE33.3KUS limited to 27.6kW AC SE66.6KUS limited to 55kW AC SE100KUS limited to 82.8kW AC Guadeloupe
SE2200, SE3000, SE3500, SE4000, France 50Hz SE5000, SE6000; SE2200H, SE1000M, SE1500M ,SE2000M, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H, SE8000H, SE10000H; SE3K-RWB, SE4K-RWB, SE5K-RWB; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K; SE50K, SE55K, SE66.6K, SE80K, SE82.8K, SE90K, SE100K, SE120K SE33.3K, SE66.6K, SE100K France -> France MV 50Hz Available from CPU v3.2016 These inverters have a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
* StorEdge Inverter without France 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
16
Supported inverters Inverter country Frequency Comments setting Guatemala SE3000A-US – SE5000A-US, USA -> Auto 60Hz SE3800H-US limited to 3.3kW AC SE3000H-US – SE11400H-US USA -> 208V SE6000H-US limited to 5kW AC USA -> 208V No SE11400H-US limited to 10kW AC Neutral
SE9KUS, SE14.4KUS, SE17.3KUS, USA -> 208V 60Hz SE43.2KUS, SE50KUS Hong Kong
SE1000M, SE1500M, SE2000M, Hong Kong 50Hz SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H, SE8000H, SE10000H; SE3K-RWB, SE4K-RWB, SE5K- RWB; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K; SE50K, SE55K, SE66.6K, SE82.8K, SE120K SE33.3K, SE66.6K, SE100K China - > China MV 50Hz This inverter has a 277/480Vac output voltage and India -> India MV is designed for connection to the medium voltage grid via a transformer
StorEdge three phase inverter; Hong Kong 50Hz SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS Hungary SE1000M, SE1500M ,SE2000M, Hungary 50Hz Available from CPU v2.09xx / v3.12xx SE2200, SE3000, SE3500, SE4000, SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K-RWB, SE4K-RWB, SE5K- RWB; SE3K, SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K; SE50K, SE55K, SE66.6K, SE82.8K, SE100K
* StorEdge Inverter without Hungary 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
17 India SE2200, SE3000, SE3500, SE4000, India 50Hz (1)Available with SetApp enabled inverters from SE5000, SE6000; SE2200H, (1) India ->India Kerala CPU v4.9.xx SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K. SE27.6K, SE55K, SE82.8K
SE33.3K, SE66.6K, SE100K India -> India MV 50Hz Available from CPU v3.19xx (1) India ->India Kerala This inverter has a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
(1) Available with SetApp enabled inverters from CPU v4.9.xx Indonesia SE1000M, SE1500M ,SE2000M, Indonesia 50Hz Available from CPU v3.16xx SE2200, SE3000, SE3500, SE4000, SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K. SE27.6K, SE30K, SE33.3K; SE66.6K, SE100K, SE120K Ireland SE2200, SE3000, SE3500, SE4000, Ireland 50Hz Available from CPU v2.0496 SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE6K SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K. SE27.6K, SE30K, SE33.3K, SE50K, SE55K, SE66.6K, SE82.8K, SE90K, SE100K
* StorEdge Inverter without Ireland 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS
18 Israel SE2200, SE3000, SE3500, SE4000, Israel -> Israel 50Hz Commercial setting for systems >50kW available SE5000, SE6000; SE2200H, Israel -> Israel – from CPU v2.07xx SE3000H, SE3500H, SE3680H, Commercial SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE33.3K, SE50K, SE55K, SE82.8K * StorEdge Inverter without Israel -> Israel 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Italy
SE1000M, SE1500M, SE2000M, Italy -> Italy 50Hz SE2200H, SE3000H, SE3500H, Italy -> Italy (No SPI) SE3680H, SE4000H, SE5000H, SE6000H; SE3K-RWB, SE4K-RWB, SE5K-RWB; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K SE15K, SE16K, SE17K, SE25K, Italy -> Italy 50Hz These inverters are approved for connection to the SE27.6K, SE30K, SE33.3K; SE50K, Italy -> Italy (No SPI) medium voltage grid according to the CEI 0-16 SE55K, SE66.6K, SE82.8K, SE90K, standard SE100K, SE120K SE33.3K, SE40K, SE66.6K, SE100K Italy -> Italy 277V No 50Hz These inverters have a 277/480Vac output voltage SPI and is designed for connection to the medium voltage grid via a transformer
* StorEdge Inverter without Italy -> Italy 50Hz * Requires StorEdge-compatible inverter backup power: Italy -> Italy (No SPI) SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H,SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS
19
Supported inverters Inverter country Frequency Comments setting Jamaica SE3000A-US – SE11400A-US, Caribbean -> Jamaica 50Hz Available from CPU v2.0496 SE3000H-US – SE11400H-US -> 240V No Neutral Can be connected to the following grids: Caribbean -> Jamaica 110/220V split phase (L-L connection) -> 220V No Neutral 240/415V WYE (L-N connection) 220V delta (L-L connection)
SE10KUS, SE20kUS, SE30KUS, Caribbean -> Jamaica 50Hz Supported in inverters shipped from Jan. 10 2014 SE33.3KUS, SE40KUS, -> 240V (No N) that have DSP1 v1.13.321; for other inverters SE66.6KUS, SE100KUS contact SolarEdge support. Can be connected to the following grid: 240/415V WYE SE20kUS limited to 17.3kW AC SE30KUS, SE33.3KUS limited to 28.9kW AC Japan
SE5500H-JP Japan 50Hz 50/60Hz Japan 60Hz
SE17K-JPI Japan -> Japan 201V 50/60Hz
SE25K-JP, SE50K-JP Japan -> Japan 380V 50/60Hz Available from CPU v3.19xx 50Hz Japan -> Japan 380V 60Hz
SE33.3K-JP, SE100K-JP Japan -> Japan MV 50/60Hz Available from CPU v3.16xx 480V 50Hz Japan -> Japan MV 480V 60Hz Jordan SE2200, SE3000, SE3500, SE4000, United Kingdom -> 50Hz GBR setting available from CPU v3.16xx; in earlier SE5000, SE6000; SE2200H, GBR versions use UK 230V SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K SE27.6K, SE30K, SE33.3K; SE50K, SE55K, SE66.6K, SE82.8K, SE90K, SE100K SE33.3K, SE66.6K, SE100K United Kingdom -> 50Hz These inverters have a 277/480Vac output voltage UK 480 and is designed for connection to the medium voltage grid via a transformer Kenya SE2200, SE3000, SE3500, SE4000, Kenya 50Hz Available from CPU v3.19xx SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE82.8K
20
Supported inverters Inverter country Frequency Comments setting Korea
SE27.6K Korea 60Hz
Kuwait SE2200, SE3000, SE3500, SE4000, Contact SolarEdge 50Hz Available from CPU v2.10xx / v3.14xx SE5000, SE6000; SE2200H, support SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K Latvia SE1000M, SE1500M ,SE2000M, Latvia 50Hz Available from CPU v2.0549 SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE8000H, SE10000H; SE3K, SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K; SE55K, SE66.6K, SE82.8K, SE100K SE30K, SE33.3K * StorEdge Inverter without Latvia 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H;
StorEdge three phase inverter;
SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS
Lithuania
SE1000M, SE1500M ,SE2000M, ; Lithuania 50Hz SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE55K, SE66.6K, SE82.8K, SE100K SE30K, SE33.3K
21 * StorEdge Inverter without Lithuania 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H;
StorEdge three phase inverter;
SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS
Luxembourg SE2200H, SE3000H, SE3500H, Europe EN-50549 50Hz Available from CPU v3.16xx SE3680H, SE4000H, SE5000H, SE6000H; SE3K-RWB, SE4K- RWB, SE5K-RWB; SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE27.6K, SE30K, SE33.3K; SE55K, SE82.8K
* StorEdge Inverter without Europe EN-50549 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H, AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; StorEdge three phase inverter: SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS Macau
SE15K, SE17K, SE25K, SE27.6K, Macau 50Hz SE30K, SE33.3K, SE66.6K, SE100K, SE120K Malaysia SE1000M, SE1500M, SE2000M, Malaysia 50Hz Available from CPU v2.09xx / v3.12xx SE2200, SE3000, SE3500, SE4000, SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K-RWB, SE4K-RWB, SE5K- RWB; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6, SE30K, SE33.3K, SE55K, SE66.6K, SE82.8K, SE100K, SE120K
22
Supported inverters Inverter country Frequency Comments setting Malta SE2200, SE3000, SE3500, SE4000, United Kingdom -> 50Hz GBR setting available from CPU v3.16xx; in earlier SE5000, SE6000; SE2200H, GBR versions use UK 230V SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17, SE25K, SE27.6K, SE30K, SE33.3K * StorEdge Inverter without United Kingdom -> 50Hz * Requires StorEdge-compatible inverter backup power: GBR GBR setting available from CPU v3.16xx; in SE2200H, SE3000H, SE3500H, earlier versions use UK 230V SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Mauritius SE2200, SE3000, SE3500, SE4000, Mauritius - > < 50kW 50Hz (1) Available with SetApp enabled inverters from SE5000, SE6000; SE2200H, Mauritius - > 50kw - CPU v4.9.xx SE3000H, SE3500H, SE3680H, 200kW SE4000H, SE5000H, SE6000H; Mauritius - > SE4K, SE5K, SE7K, SE8K, SE9K, > 200kW SE10K, SE12.5K, SE15K, SE16K, (1)Mauritius -> 200kW SE17K, SE25K, SE27.6, SE30K, - 2MW SE33.3K; SE55K, SE82.8K
23
Supported inverters Inverter country Frequency Comments setting Mexico SE3000A-US – SE11400A-US, Mexico -> 220V 60Hz Can be connected to the following grids: SE3000H-US – SE10000H-US Mexico -> 240V 110/220V split phase (L-L connection) 127/220V WYE (L-L connection) 240/420V WYE (L-N connection)
SE9KUS, SE17.3KUS, Mexico -> 220V 60Hz 127/220V WYE grid only SE14.4KUS, SE43.2KUS
SE10KUS, SE20KUS, SE30KUS, Mexico -> 240V 60Hz Can be connected to the following grids: SE40KUS, SE33.3KUS, Mexico -> 277V 277/480V WYE SE66.6KUS, SE100KUS 240/420V WYE; when connected to this grid: SE10KUS limited to 8.6kW AC SE20kUS limited to 17.3kW AC,
SE30KUS, SE33.3KUS limited to 28.6kW AC SE66.6KUS limited to 57.4kW AC SE100KUS limited to 86.2kW AC
Morocco
SE2200, SE3000, SE3500, SE4000, France 50Hz SE5000, SE6000; SE2200H, SE1000M, SE1500M ,SE2000M, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H, SE8000H, SE10000H; SE3K-RWB, SE4K-RWB, SE5K-RWB; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K; SE50K, SE55K, SE66.6K, SE80K, SE82.8K, SE90K, SE100K, SE120K SE33.3K, SE66.6K, SE100K France -> France MV 50Hz Available from CPU v3.2016 These inverters have a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer Namibia
SE2200, SE3000, SE3500, SE4000, South Africa 50Hz SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K,
24
Supported inverters Inverter country Frequency Comments setting
SE17K, SE25K, SE27.6K, SE30K, SE33.3K; SE50K, SE55K, SE66.6K, SE82.8K, SE100K Netherlands
SE1000M, SE1500M, SE2000M, Netherlands 50Hz SE2200H, SE3000H, SE3500H, 230/400V SE3680H, SE4000H, SE5000H, SE3K-RWB, SE4K-RWB, SE5K- RWB; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE66.6K, SE82.8K, SE100K SE33.3K, SE40K, SE66.6K, SE100K, Netherlands 480V 50Hz These inverters have a 277/480Vac output voltage SE120K and is designed for connection to the medium voltage grid via a transformer Available from CPU v3.2167
*StorEdge Inverter without Netherlands 50Hz * Requires StorEdge-compatible inverter backup power: 230/400V SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H,
StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS
New Zealand SE2200, SE3000, SE3500, SE4000, New Zealand -> 50Hz New Zealand setting available from CPU v3.16xx SE4600, SE5000, SE6000, SE7300; Vector SE2500H, SE3000H, SE3500H, Australia -> Australia SE4000H, SE4600H, SE6000H; SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K,SE30K, SE33.3K SE50K, SE66.6K, SE82.8K, SE100K
* StorEdge Inverter without New Zealand -> 50Hz * Requires StorEdge-compatible inverter backup power: Vector SE2200H, SE3000H, SE3500H, Australia -> Australia SE4000H, SE4600H, SE5000H, SE6000H, SE7300H AC Coupled Inverter; SE2500H, SE3000H, SE3500H, SE4000H, SE4600H, SE6000H, * AC Coupled Inverters: SE3000H, SE5000H
StorEdge Inverter with backup New Zealand -> 50Hz Available from CPU v3.18xx power: Vector SE5000-AUS - SE6000-AUS Australia -> Australia
25
Supported inverters Inverter country Frequency Comments setting Norway SE1000M, SE1500M ,SE2000M, Norway 50Hz Available from CPU v2.10xx / v3.14xx SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K SE33.3K, SE55K, SE66.6K, SE82.8K, SE100K SE3K, SE4K, SE5K, SE6K SE7K, Norway -> Norway 50Hz Can be connected to the following grid: 220/230V SE8K, SE9K, SE10K, SE12.5K, Delta True Delta SE15K, SE16K, SE17K, SE25K, Inverter AC power is limited; requires inverter SE27.6K, SE30K SE33k, adjustment. For details refer to: SE55K, SE66.6K, SE82.8K, https://www.solaredge.com/sites/default/files/se_t SE100K hree_phase_inverters_for_delta_grids.pdf StorEdge three phase inverter;
SE5K-RWS, SE7K-RWS, SE8K- Available from CPU v3.2167 RWS, SE10K-RWS
* StorEdge Inverter without Norway 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H;
StorEdge three phase inverter;
SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS
Panama
SE3000A-US - SE11400A-US, Contact SolarEdge SE3000H-US-SE7600H-US, support SE9KUS, SE17.3KUS, SE10KUS, SE20KUS, SE30KUS Peru
SE1000M, SE1500M, SE2000M; Peru 60Hzun SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K; SE55K, SE82.8K Philippines SE1000M, SE1500M, SE2000M, Philippines 60Hz Can be connected to the following grids: SE2200, SE3000, SE3500, SE4000, 115/230V split phase (L-L connection) SE5000, SE6000; SE2200H, 220/380V WYE (L-N connection)
26
Supported inverters Inverter country Frequency Comments setting
SE3000H, SE3500H, SE3680H, 230/400V WYE (L-N connection) SE4000H, SE5000H, SE6000H; 240/420V WYE (L-N connection) SE4K, SE5K, SE7K, SE8K, Philippines 60Hz Can be connected to the following grids: SE9K, SE10K, SE12.5K, SE15K, 220/380V WYE SE16K, SE17K, SE25K, SE27.6K; 230/400V WYE SE30K, SE33.3K, SE50K, SE55K, 240/420V WYE SE66.6K, SE82.8K, SE90K, SE100K SE33.3K, SE40K, SE66.6K, SE100K, Philippines -> 60Hz Available from CPU v3.19xx SE120K Philippines MV These inverters have a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer SE7K, SE8K, SE9K, SE10K, Philippines -> 230V 60Hz Can be connected to the following grid: 220/230V SE12.5K, SE15K, SE16K, SE17K, L-L No N True Delta SE25K, SE27.6K; Inverter AC power is limited; requires inverter SE55K, SE82.8K adjustment. For details refer to: https://www.solaredge.com/sites/default/files/se_t hree_phase_inverters_for_delta_grids.pdf) Available from CPU v3.2167 Poland
SE2200H, SE3000H, SE3500H, Poland 50Hz SE3680H, SE4000H, SE5000H, SE6000H; SE3K-RWB, SE4K-RWB SE5K-RWB; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K; SE50K, SE55K, SE66.6K, SE82.8K, SE90K, SE100K SE66.6K, SE80K, SE100K, SE120K Poland 480V 50Hz These inverters have a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
* StorEdge Inverter without Poland 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS
27
Supported inverters Inverter country Frequency Comments setting Portugal
SE1000M, SE1500M, SE2000M, Portugal 50Hz SE2200, SE3000, SE3500, SE4000, SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE40K, SE50K, SE55K, SE66.6K, SE82.8K, SE100K
* StorEdge Inverter without Portugal 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H,
* AC Coupled Inverters: SE3680H, SE5000H
StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS Romania
SE2200, SE3000, SE3500, SE4000, Romania 50Hz SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6, SE30K, SE33.3K
28
* StorEdge Inverter without Romania 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS
29 Supported inverters Inverter country Frequency Comments setting Seychelles
SE2200, SE3000, SE3500, SE4000, Mauritius 50Hz SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6, SE30K, SE33.3K Singapore
SE1000M, SE1500M, SE2000M, Singapore 50Hz SE2200, SE3000, SE3500, SE4000, SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K-RWB, SE4K-RWB, SE5K-RWB; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6, SE30K, SE33.3K; SE50K, SE55K, SE66.6K, SE82.8K, SE90K, SE100K, SE120K SE33.3K, SE66.6K, SE100K United Kingdom -> 50Hz These inverters have a 277/480Vac output voltage UK 480 and is designed for connection to the medium voltage grid via a transformer Slovakia SE1000M, SE1500M ,SE2000M Slovakia -> Slovakia 50Hz Available from CPU v3.1968 SE2200H, SE3000H, SE3500H, ZSED SE3680H, SE4000H, SE5000H, Slovakia -> Slovakia SE6000H; SE8000H, SE10000H; SSED SE3K, SE5K, SE7K, SE8K, SE9K, Slovakia -> Slovakia SE10K, SE12.5K, SE15K, SE16K, VSD SE17K, SE30K, SE33.3K, SE40K, SE50K, SE55K, SE66.6K, SE82.8K, SE100K
* StorEdge Inverter without Slovakia -> Slovakia 50Hz * Requires StorEdge-compatible inverter backup power: ZSED SE2200H, SE3000H, SE3500H, Slovakia -> Slovakia SE4000H, SE5000H, SE6000H, SSED SE3500H Slovakia -> Slovakia AC Coupled Inverter; SE2200H, VSD SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS
30
Supported inverters Inverter country Frequency Comments setting Slovenia
SE2200, SE3000, SE3500, SE4000, Slovenia 50Hz SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K, SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE82.8K,
SE40K Slovenia 480V 50Hz
* StorEdge Inverter without Slovenia 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
South Africa
SE2200, SE3000, SE3500, SE4000, South Africa 50Hz SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE33.3K, SE50K, SE55K, SE66.6K, SE82.8K, SE100K SE33.3K, SE66.6K, SE80K, SE120K South Africa -> 50Hz Available from CPU v3.19xx South Africa MV This inverter has a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
* StorEdge Inverter without South Africa 50Hz * Requires StorEdge-compatible inverter backup power: SE2200, SE3000, SE3500, SE4000, SE5000, SE6000, SE3500 AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
StorEdge Inverter with backup South Africa 50Hz Available from CPU v3.18xx power: SE5000-ZAS - SE6000-ZAS
31
Supported inverters Inverter country Frequency Comments setting Spain
SE2200, SE3000, SE3500, SE4000, Spain 230/400V 50Hz SE5000, SE6000; Spanish Islands SE1000M, SE1500M, SE2000M; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H, SE8000H, SE10000H; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE40K; SE50K, SE55K, SE66.6K, SE80K, SE82.8K, SE90K, SE100K, SE120K SE33.3K, SE40K, SE66.6K, SE100K Spain 480V 50Hz Available from CPU v3.20xx These inverters have a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer * StorEdge Inverter without Spain 230/400V 50Hz * Requires StorEdge-compatible inverter backup power: Spanish Islands SE2200H, SE3000H, SE3500H, SE3680H SE4000H, SE5000H, SE6000H * AC Coupled Inverters: SE3680H, SE5000H
StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS
Sri Lanka
SE2200, SE3000, SE3500, SE4000, Sri Lanka 50Hz SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K St. Lucia
SE3000A-US - SE11400A-US, Caribbean -> St. 50Hz SE3000H-US - SE11400H-US Lucia St. Vincent SE2200, SE3000, SE3500, SE4000- United Kingdom -> 50Hz GBR setting available from CPU v3.16xx; in earlier 16A; SE2200H SE3000H, GBR versions use UK 230V SE3500H, SE3680H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K
32
Supported inverters Inverter country Frequency Comments setting Sweden
SE2200H, SE3000H, SE3500H, Sweden 50Hz SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE20K, SE25K, SE27.6K, SE30K, SE33.3K, SE40K, SE50K, SE55K, SE82.8K, SE90K, SE100K SE66.6K, SE80K, SE100K, SE120K Sweden - > Sweden 50Hz Available from CPU v3.20xx 277 These inverters have a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
* StorEdge Inverter without Sweden 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, SE3500H AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
StorEdge three phase inverter: SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS Switzerland SE1000M, SE1500M, SE2000M, Switzerland (Schweiz) 50Hz 400V grid connection acc. to NA/EEA-NE7-CH 2020 SE2200H, SE3000H, SE3500H, SE3680H, SE3K-RWB, SE4K-RWB, SE5K- RWB SE3K, SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE66.6K, SE82.8K, SE90K, SE100K, SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS SE2200H, SE3000H, SE3500H, Switzerland (Schweiz) 50Hz 400V grid connection acc. to NA/EEA-NE7-CH 2020 SE3680H, SE3K-RWB, SE4K-RWB, SE5K- StorEdge compatible Inverter (AC- or DC-coupled) RWB without backup power SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS SE12.5K, SE15K, SE16K, SE17K, Switzerland (Schweiz) 50Hz 400V grid connection acc. to NA/EEA 2014 SE25K, SE27.6K, SE30K, + Site specific adjustment of parameters acc. to SE33.3K, grid-operator SE55K, SE66.6K, SE82.8K, SE90K, SE100K
33
Supported inverters Inverter country Frequency Comments setting Tahiti SE2200, SE3000, SE3500, SE4000, Tahiti 60Hz Available from CPU v2.09xx / v3.12xx SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K Taiwan
SE3000H, SE4000H, SE5000H, Taiwan 60Hz SE6000H; SE2000M; SE15K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE66.6K, SE82.8K SE33.3K, SE40K, SE100K, SE120K Taiwan -> Taiwan MV 60Hz Available from CPU v3.19xx These inverters have a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer SE15K, SE17K, SE25K, Taiwan -> Taiwan 60Hz Can be connected to the following grid: 220/230V SE27.6K, SE30K, SE33.3K, 220V L-L No N True Delta SE66.6K, SE100K Inverter AC power is limited; requires inverter adjustment. For details refer to: https://www.solaredge.com/sites/default/files/s e_three_phase_inverters_for_delta_grids.pdf) Available from CPU v3.2167 Thailand SE5000, SE5000H, SE10K, Thailand -> Thailand 50Hz Available from CPU v3.16xx SE55K, SE82.8K SE25K, SE27.6K, MEA SE5000H approved for PEA only Thailand -> Thailand PEA
SE33.3K, SE66.6K, SE100K Thailand -> Thailand 50Hz Available from CPU v3.2016 MEA MV Thailand -> Thailand These inverters have a 277/480Vac output voltage PEA MV and is designed for connection to the medium voltage grid via a transformer Turkey
SE2200, SE3000, SE3500, SE4000, Turkey -> Turkey 50Hz SE5000, SE6000; SE2200H, Turkey -> N. Cyprus SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE82.8K SE33.3K, SE66.6K, SE100K Turkey -> Turkey MV 50Hz Available from CPU v3.19xx
34 * StorEdge Inverter without Turkey -> Turkey 50Hz * Requires StorEdge-compatible inverter backup power: Turkey -> N. Cyprus SE2200, SE3000, SE3500, SE4000, SE5000, SE6000, SE3500 * AC Coupled Inverter: SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H Ukraine SE1000M, SE1500M ,SE2000M Europe EN50438 50Hz Available from CPU v3.16xx SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE8000H, SE10000H; SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE27.6K, SE30K, SE33.3K SE50K, SE55K, SE82.8K * StorEdge Inverter without Europe EN50438 50Hz * Requires StorEdge-compatible inverter backup power: SE2200H, SE3000H, SE3500H, SE4000H, SE5000H, SE6000H, AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H;
StorEdge three phase inverter;
SE5K-RWS, SE7K-RWS, SE8K- RWS, SE10K-RWS
United Kingdom SE1000M, SE1500M, SE2000M, United Kingdom -> 50Hz N. Ireland setting available from CPU v2.10xx / SE2200H, SE3000H, SE3500H, GBR v3.14xx SE3680H, SE4000H, SE5000H, United Kingdom -> GBR setting available from CPU v3.16xx; in earlier SE6000H, SE8000H, SE10000H; N. Ireland versions use UK 230V SE3K-RWB, SE4K-RWB, SE5K- RWB; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K; SE50K, SE55K, SE66.6K, SE82.8K, SE90K, SE100K
SE33.3K, SE66.6K, SE100K United Kingdom -> 50Hz These inverters have a 277/480Vac output UK 480 voltage and is designed for connection to the medium voltage grid via a transformer
35 * StorEdge Inverter without United Kingdom -> 50Hz * Requires StorEdge-compatible inverter backup power: GBR SE2200H, SE3000H, SE3500H, United Kingdom -> SE4000H, SE5000H, SE6000H, N. Ireland SE3500H * AC Coupled Inverter; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; * AC Coupled Inverters: SE3680H, SE5000H
StorEdge three phase inverter; SE5K-RWS, SE7K-RWS, SE8K-RWS, SE10K-RWS Uruguay
SE1000M, SE1500M, SE2000M; Uruguay 50Hz SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K, SE4K, SE5K, SE6K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE82.8K United States (including Guam, Puerto Rico, Saipan and US Virgin Islands, excluding Hawaii and New York) SE3000A-US - SE11400A-US, USA -> Auto 60Hz Refer to the inverter datasheet for full inverter- SE3000H-US - SE11400H-US USA -> 240V grid compatibility: USA -> 240V No https://www.solaredge.com/sites/default/files/se- Neutral hd-wave-single-phase-inverter-with-setapp- USA -> 208V datasheet-na.pdf USA -> 208V No Rule 21 setting available from CPU v3.16xx Neutral ISO-NE setting available from CPU v3.24xx USA (Rule 21) -> Rule 21 Auto USA (Rule 21) -> Rule 21 240V USA (Rule 21) -> Rule 21 240V No Neutral USA (Rule 21) -> Rule 21 208V USA (Rule 21) -> Rule 21 208V No Neutral US NE -> ISO-NE 240V US NE -> ISO-NE 240V No-N
36
Supported inverters Inverter country Frequency Comments setting United States (Hawaii only) SE3000A-US - SE11400A-US, Hawaii -> XXX Auto 60Hz Refer to the inverter datasheet for full inverter- SE3000H-US - SE11400H-US Hawaii -> XXX 240V grid compatibility: Hawaii -> XXX 240V https://www.solaredge.com/sites/default/files/se- No Neutral hd-wave-single-phase-inverter-with-setapp- Hawaii -> XXX 208V datasheet-na.pdf Hawaii -> XXX 208V Use Hawaii settings for HECO grid settings No Neutral Molokai and Lanai setting available from CPU XXX = Hawaii / Kauai v2.10xx / v3.14xx / Molokai and Lanai
SE9KUS, SE14.4KUS, Hawaii -> XXX 208V 60Hz 120/208V WYE grid or 208V Delta grid (SE9KUS SE17.3KUS, SE43.2KUS XXX = Hawaii / Kauai delta grid support for inverters with part number / Molokai and Lanai SE9K-US228NNU4) Use Hawaii settings for HECO grid settings Molokai and Lanai setting available from CPU v2.10xx / v3.14xx
SE10KUS, SE20KUS, SE30KUS, Hawaii -> XXX 277V 60Hz 277/480V WYE grid only SE33.3KUS, SE40KUS XXX = Hawaii / Kauai Use Hawaii settings for HECO grid settings SE66.6KUS, SE100KUS / Molokai and Lanai Molokai and Lanai setting available from CPU v2.10xx / v3.14xx SE7600A-USS (StorEdge inverter) Hawaii -> XXX Auto 60Hz Use Hawaii settings for HECO grid settings Hawaii -> XXX 240V Available from CPU v3.18xx Hawaii -> XXX 240V No Neutral XXX = Hawaii / Kauai / Molokai and Lanai United States (New York only) SE3000A-US - SE11400A-US, NY -> New-York 60Hz Refer to the inverter datasheet for full inverter- SE3000H-US - SE11400H-US Auto grid compatibility: NY -> New-York https://www.solaredge.com/sites/default/files/se- 240V hd-wave-single-phase-inverter-with-setapp- datasheet-na.pdf
NY -> New-York Available from CPU v2.10xx / v3.14xx 240V No Neutral NY -> New-York 208V NY -> New-York 208V No Neutral SE9KUS, SE14.4KUS, NY -> New-York 60Hz 120/208V WYE grid or 208V Delta grid (SE9KUS SE17.3KUS, SE43.2KUS 208V delta grid support for inverters with part number SE9K-US228NNU4) Available from CPU v2.10xx / v3.14xx
SE10KUS, SE20kUS, NY -> New-York 60Hz 277/480V WYE grid only SE30KUS, SE33.3KUS, 277V Available from CPU v2.10xx / v3.14xx SE40KUS, SE66.6KUS, SE100KUS
37 SE7600A-USS (StorEdge NY -> New-York 60Hz Available from CPU v3.18xx inverter) Auto NY -> New-York 240V NY -> New-York 240V No Neutral Vietnam SE1000M, SE1500M, SE2000M, Vietnam 50Hz Available from CPU v3.225x SE2200, SE3000, SE4000, SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE3K-RWB, SE4K-RWB, SE5K- RWB; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE27.6K, SE30K, SE33.3K, SE55K, SE66.6K, SE82.8K, SE100K, SE120K Zimbabwe SE2200, SE3000, SE3500, SE4000, Zimbabwe 50Hz Available from CPU v3.16xx SE5000, SE6000; SE2200H, SE3000H, SE3500H, SE3680H, SE4000H, SE5000H, SE6000H; SE4K, SE5K, SE7K, SE8K, SE9K, SE10K, SE12.5K, SE15K, SE16K, SE17K, SE25K, SE30K, SE33.3K SE27.6K