Last update: Nov. 2016 Countries Supported by the SolarEdge Inverters The SolarEdge inverters can be used in many different countries. This document details countries where SolarEdge approves installation of its inverters. Installation should always be done in compliance with local regulations, and in case of a conflict between local regulations and this document, local regulations apply.
Summary
The SolarEdge inverters may be installed in the following countries. Unless stated otherwise, the approval refers to low voltage installations. For medium voltage installations, please contact SolarEdge support. Please refer to the country details below for more information, as in some countries not all grids are supported or not all inverter models are supported. In supported countries, connection of supported inverters to non-supported grids is permitted through a transformer, if the secondary connection (transformer connection to the inverter) is identical to a supported grid.
NOTE Transformer procurement, installation, maintenance and support are the responsibility of the installer. Damage to the inverter due to incorrect transformer installation or use of a transformer that is incompatible with the SolarEdge system will render the SolarEdge warranty invalid. NOTE Prior to purchasing a StorEdge system verify battery availablity and service in the country. Availability of SolarEdge StorEdge products does not guarantee battery availabllity. A country listed in bold indicates that StorEdge inverters with backup are approved for installation in that country.
Aruba France Mauritius Tahiti Australia Germany Mexico Taiwan Austria Ghana Namibia Thailand Barbados Greece The Netherlands Turkey Belarus Grenada New Zealand Ukraine Belgium Guatemala Norway United Kingdom Bermuda Hungary Panama USA Botswana India Philippines Zimbabwe Bulgaria Indonesia Poland Canada Ireland Portugal Cape Verde Israel Romania China Italy Seychelles Costa Rica Jamaica Singapore Croatia Japan Slovakia Curacao Jordan Slovenia Cyprus Kenya South Africa Czech Republic Kuwait Spain Denmark Latvia Sri Lanka Dubai Lithuania St. Lucia El Salvador Luxembourg St. Vincent Estonia Malaysia Sweden Finland Malta Switzerland
For installation in countries or with grids not detailed in this document, contact SolarEdge support: [email protected]
1
Detailed Information per Country
The table below details for each of the above countries: 1. Supported inverters: which SolarEdge inverters may be used in the country
2. Inverter country setting: to what country setting the inverter should be configured in order to comply with the local grid requirements. Some countries have a submenu that should be used; sub-entries are indicated with the following symbol: ->
3. Frequency: the nominal inverter AC frequency for the corresponding country setting
4. Comments: additional information about the inverter and grid support
2
Supported inverters Inverter country setting Frequency Comments
Aruba
SE3000A-US – Caribbean -> Aruba 60Hz Available from CPU v2.07xx SE11400A-US Can be connected to the following grid: 127/220V (L-L connection) SE3800A-US limited to 3.5kW AC SE6000A-US limited to 5.5kW AC SE11400A-US approved only for installations with no LVRT (low voltage ride through) requirement; if required – contact SolarEdge support
SE9kUS Caribbean -> Aruba 60Hz Available from CPU v2.07xx Can be connected to the following grid: 127/220V
Australia
SE2200 - SE6000, Australia -> Australia 50Hz Use Queensland setting when QLD wider voltage range SE5k - SE27.6k Australia -> Queensland is required; available from CPU v2.0496 Australia -> Victoria Victoria setting available from CPU v3.19xx
StorEdge without Australia -> Australia 50Hz Requires StorEdge-compatible inverter and installation backup power: Australia -> Queensland of StorEdge Interface; refer to application note. SE2200-SE6000, Australia -> Victoria SE3500 AC Coupled Inverter
StorEdge with Australia -> Australia 50Hz Available from CPU v3.18xx backup power: Australia -> Queensland SE5000-AUS - Australia -> Victoria SE6000-AUS
Austria
SE2200 - SE6000, Austria 50Hz SE2200H – SE3680H, SE4k - SE27.6k
StorEdge without Austria 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Barbados
SE3000A-US - Caribbean -> Barbados 50Hz Available from CPU v2.0496 SE11400A-US 230V No N Can be connected to the following grids: 115/230V split phase or 3-wire (L-L connection) 230/400V WYE (L-N connection)
SE9KUS Caribbean -> Barbados 50Hz Available from CPU v2.09xx / v3.12xx 115V Can be connected to the following grid: 115/200V WYE
3
Supported inverters Inverter country setting Frequency Comments
SE10kUS - SE20kUS Caribbean -> Barbados 50Hz Supported in inverters shipped from Jan. 10 2014 that 230V (No N) have DSP1 v1.13.321; for other inverters contact SolarEdge support. Can be connected to the following grid: 230/400V WYE SE20kUS limited to 16.5kW AC
Belarus
SE2200 – SE6000, Europe EN50438 50Hz Available from CPU v3.16xx SE4k - SE27.6k
StorEdge without Europe EN50438 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Belgium
SE2200 - SE5000, Belgium 50Hz Refer to the following note for more details about grid SE2200H – SE3680H, compliance: SE4k - SE27.6k http://www.solaredge.com/files/pdfs/belgian-grids- application-note.pdf
StorEdge without Belgium 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE5000, SE3500 AC Coupled Inverter
StorEdge with Belgium 50Hz Available from CPU v3.18xx backup power: SE5000-RWS
Bermuda
SE3000A-US - USA -> Auto 60Hz Refer to the inverter datasheet for full inverter-grid SE11400A-US USA -> 240V compatibility: USA -> 240V No Neutral http://www.solaredge.us/files/pdfs/products/inverters/ se-single-phase-us-inverter-datasheet.pdf USA -> 208V
USA -> 208V No Neutral
SE9kUS USA -> 208V 60Hz 120/208V WYE grid only
SE10kUS – SE20kUS USA -> 277V 60Hz 277/480V WYE grid only
Botswana
SE2200 - SE6000, South Africa 50Hz SE2200H – SE3680H, SE4k - SE27.6k
Bulgaria
SE2200 - SE6000, Bulgaria 50Hz SE2200H – SE3680H, SE5k - SE27.6k
4
Supported inverters Inverter country setting Frequency Comments
StorEdge without Bulgaria 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Canada
SE3000A-US-CAN - USA -> Auto 60Hz Refer to the inverter datasheet for full inverter-grid SE11400A-US-CAN USA -> 240V compatibility: USA -> 240V No Neutral http://www.solaredge.us/files/pdfs/products/inverters/ se-single-phase-us-inverter-datasheet.pdf USA -> 208V
USA -> 208V No Neutral
SE9kUS-CAN, USA -> 208V 60Hz 120/208V WYE grid only SE14.4KUS
SE10kUS-CAN, USA -> 277V 60Hz 277/480V WYE grid only SE20kUS-CAN, SE33.3KUS
Cape Verde
SE2200 – SE6000 Contact SolarEdge support 50Hz
SE4k – SE27.6k Cape Verde 50Hz Available from CPU version 3.18xx
China
SE2200 – SE6000, China 50Hz All systems must be approved by SolarEdge; contact SE5k - SE17k SolarEdge Support for details
Costa Rica
SE3000A-US - USA -> Auto 60Hz Refer to the inverter datasheet for full inverter-grid SE11400A-US USA -> 240V compatibility: USA -> 240V No Neutral http://www.solaredge.us/files/pdfs/products/inverters/ se-single-phase-us-inverter-datasheet.pdf USA -> 208V
USA -> 208V No Neutral
SE9kUS USA -> 208V 60Hz 120/208V WYE grid only
SE10kUS – SE20kUS USA -> 277V 60Hz 277/480V WYE grid only
Croatia
SE2200 - SE5000, Croatia 50Hz Available from CPU v2.0496 SE4k - SE27.6k
StorEdge without Croatia 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE5000, SE3500 AC Coupled Inverter
Curacao
SE2200 – SE5000 Caribbean -> Curacao 50Hz Available from CPU v2.0637 Can be connected to the following grids:
5
Supported inverters Inverter country setting Frequency Comments 127/220V WYE (L-L connection) 110/220V split phase (L-L connection) 220/380V WYE (L-N connection)
SE4k - SE27.6k Caribbean -> Curacao 50Hz Available from CPU v2.0637 Can be connected to the following grid: 220/380V WYE Systems 100kW and larger must be approved by SolarEdge; contact SolarEdge Support for details
Cyprus
SE2200 – SE6000, Cyprus 50Hz SE5k - SE27.6k Cyprus 240V
StorEdge without Cyprus 50Hz Requires StorEdge-compatible inverter and installation backup power: Cyprus 240V of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Czech Republic
SE2200 - SE6000, Czech Republic 50Hz SE2200H – SE3680H, SE5k - SE17k
StorEdge without Czech Republic 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Denmark
SE2200 - SE6000, Denmark -> Denmark 50Hz Use Residential settings to comply with 16Aac and 6kW SE4k - SE27.6k Denmark -> Denmark limits of residential systems Residen. Use VDE settings for VDE-AR-N-4105 grid settings; Denmark -> Denmark VDE Available from CPU v2.0496 Denmark -> Denmark VDE Res.
StorEdge without Denmark -> Denmark 50Hz Requires StorEdge-compatible inverter and installation backup power: Denmark -> Denmark of StorEdge Interface; refer to application note. SE2200-SE6000, Residen. SE3500 AC Coupled Denmark -> Denmark VDE Inverter Denmark -> Denmark VDE Res.
Dubai
SE2200 – SE6000 Dubai 50Hz Available from CPU v3.18xx
SE4k - SE27.6k Dubai 50Hz Available from CPU v3.18xx
El Salvador
SE3000A-US - USA -> Auto 60Hz
6
Supported inverters Inverter country setting Frequency Comments SE11400A-US USA -> 240V USA -> 240V No Neutral
Estonia
SE2200 - SE4000- Portugal 50Hz 16A, SE4k-SE27.6k
StorEdge without Portugal 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE4000-16A, SE3500 AC Coupled Inverter
Finland
SE2200 – SE4000- Finland 50Hz Available from CPU v3.18xx 16A
SE4k – SE27.6k Finland 50Hz Available from CPU v3.18xx
StorEdge without Finland 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE4000-16A, SE3500 AC Coupled Inverter
France
SE2200 - SE6000, France 50Hz SE2200H – SE3680H, SE4k - SE27.6k
StorEdge without France 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
StorEdge with France 50Hz Available from CPU v3.18xx backup power: SE5000-RWS - SE6000-RWS
Germany
SE2200 - SE5000, Germany 50Hz SE2200H – SE3680H, SE4k - SE12.5k
SE15k-SE27.6k Germany -> Germany 50Hz These inverters are approved for connection to the Germany -> Germany medium voltage grid according to the BDEW standard; MVGC use Germany MVG
SE33.3K Germany -> MVGC 480 50Hz This inverter has a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
StorEdge without Germany 50Hz Requires StorEdge-compatible inverter and installation
7
Supported inverters Inverter country setting Frequency Comments backup power: of StorEdge Interface; refer to application note. SE2200-SE5000, SE3500 AC Coupled Inverter
Ghana
SE2200 - SE6000, Ghana 50Hz Available from CPU v3.18xx SE5k - SE27.6k
Greece
SE2200 - SE6000, Greece -> Greece 50Hz SE2200H – SE3680H, Continent SE4k - SE27.6k Greece -> Greece Islands
StorEdge without Greece -> Greece 50Hz Requires StorEdge-compatible inverter and installation backup power: Continent of StorEdge Interface; refer to application note. SE2200-SE6000, Greece -> Greece Islands SE3500 AC Coupled Inverter
Grenada
SE3000A-US - Grenada 50Hz Available from CPU v3.18xx SE11400A-US Can be connected to the following grid: 230/400V WYE (L-N connection)
SE9KUS Grenada 50Hz Available from CPU v3.18xx Can be connected to the following grid: 230/400V WYE
SE10kUS - SE20kUS Grenada 50Hz Available from CPU v3.18xx Can be connected to the following grid: 230/400V WYE SE20kUS limited to 16.5kW AC
Guatemala
SE3000A-US – USA -> Auto 60Hz SE5000A-US USA -> 208V USA -> 208V No Neutral
SE9kUS USA -> 208V 60Hz
Hungary
SE2200 - SE6000, Hungary 50Hz Available from CPU v2.09xx / v3.12xx SE2200H – SE3680H, SE5k - SE27.6k
StorEdge without Hungary 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
India
SE2200 - SE6000, India 50Hz SE4k - SE27.6k
8
Supported inverters Inverter country setting Frequency Comments
SE33.3k India -> India MV 50Hz Available from CPU v3.19xx This inverter has a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
Indonesia
SE2200 - SE6000, Indonesia 50Hz Available from CPU v3.16xx SE5K-SE17K
Ireland
SE2200 - SE6000, Ireland 50Hz Available from CPU v2.0496 SE2200H – SE3680H, SE4k - SE27.6k
StorEdge without Ireland 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Israel
SE2200 - SE6000, Israel -> Israel 50Hz Commercial setting for systems >50kW available from SE4k - SE27.6k Israel -> Israel - CPU v2.07xx Commercial
StorEdge without Israel -> Israel 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Italy
SE2200 - SE6000, Italy -> Italy 50Hz SE4k - SE12.5k Italy -> Italy (No SPI)
SE15k-SE27.6k Italy -> Italy 50Hz These inverters are approved for connection to the Italy -> Italy (No SPI) medium voltage grid according to the CEI 0-16 standard
SE33.3k Italy -> Italy 277V No SPI 50Hz This inverter has a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
StorEdge without Italy -> Italy 50Hz Requires StorEdge-compatible inverter and installation backup power: Italy -> Italy (No SPI) of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
StorEdge with Italy -> Italy 50Hz Available from CPU v3.18xx backup power: SE5000-RWS - SE6000-RWS
Jamaica
9
Supported inverters Inverter country setting Frequency Comments
SE3000A-US - Caribbean -> Jamaica -> 50Hz Available from CPU v2.0496 SE11400A-US 240V No Neutral Can be connected to the following grids: Caribbean -> Jamaica -> 110/220V split phase (L-L connection) 220V No Neutral 240/415V WYE (L-N connection) 220V delta (L-L connection)
SE10kUS - SE20kUS Caribbean -> Jamaica -> 50Hz Supported in inverters shipped from Jan. 10 2014 that 240V (No N) have DSP1 v1.13.321; for other inverters contact SolarEdge support. Can be connected to the following grid: 240/415V WYE SE20kUS limited to 17.3kW AC
Japan
SE25K-JP Japan -> Japan 380V 50Hz 50/60Hz Available from CPU v3.19xx Japan -> Japan 380V 60Hz
SE33.3K-JP Japan -> Japan MV 480V 50/60Hz Available from CPU v3.16xx 50Hz Japan -> Japan MV 480V 60Hz
Jordan
SE2200 - SE6000, United Kingdom -> UK 50Hz SE2200H – SE3680H, 230V SE4k - SE27.6k
Kenya
SE2200 - SE6000, Kenya 50Hz Available from CPU v3.19xx SE4k - SE27.6k
Kuwait
SE2200 - SE6000, Contact SolarEdge support 50Hz Available from CPU v2.10xx / v3.14xx SE4k - SE27.6k
Latvia
SE2200 - SE4000- Latvia 50Hz Available from CPU v2.0549 16A, SE2200H – SE3680H, SE5k - SE27.6k
StorEdge without Latvia 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE4000-16A, SE3500 AC Coupled Inverter
Lithuania
SE2200 - SE6000, Lithuania 50Hz SE2200H – SE3680H, SE4k - SE27.6k
StorEdge without Lithuania 50Hz Requires StorEdge-compatible inverter and installation
10
Supported inverters Inverter country setting Frequency Comments backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Luxembourg
SE2200 - SE6000, Europe EN50438 50Hz Available from CPU v3.16xx SE4k - SE27.6k
StorEdge without Europe EN50438 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Malaysia
SE2200 - SE6000, Malaysia 50Hz Available from CPU v2.09xx / v3.12xx SE4k - SE27.6k
Malta
SE2200 - SE6000, United Kingdom -> UK 50Hz SE4k - SE27.6k 230V
StorEdge without United Kingdom -> UK 50Hz Requires StorEdge-compatible inverter and installation backup power: 230V of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Mauritius
SE2200 - SE6000, Mauritius 50Hz SE4k - SE27.6k
Mexico
SE3000A-US - Mexico -> 220V 60Hz Can be connected to the following grids: SE11400A-US Mexico -> 240V 110/220V split phase (L-L connection) 127/220V WYE (L-L connection) 240/420V WYE (L-N connection)
SE9kUS, SE14.4KUS Mexico -> 220V 60Hz 127/220V WYE grid only
SE10kUS, SE20kUS, Mexico -> 240V 60Hz Can be connected to the following grids: SE33.3KUS Mexico -> 277V 240/420V WYE; when connected to this grid the SE10kUS is limited to 8.6kW AC, the SE20kUS is limited to 17.3kW AC and the SE33.3KUS is limited to 28.6kW AC 277/480V WYE
Namibia
SE2200 - SE6000, South Africa 50Hz SE2200H – SE3680H, SE4k - SE27.6k
11
Supported inverters Inverter country setting Frequency Comments
The Netherlands
SE2200 - SE6000, Netherlands 50Hz SE2200H – SE3680H, SE4k - SE27.6k
StorEdge without Netherlands 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
New Zealand
SE2200 - SE6000, New Zealand -> Vector 50Hz New Zealand setting available from CPU v3.16xx SE5k - SE27.6k Australia -> Australia
StorEdge without New Zealand -> Vector 50Hz Requires StorEdge-compatible inverter and installation backup power: Australia -> Australia of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
StorEdge with New Zealand -> Vector 50Hz Available from CPU v3.18xx backup power: Australia -> Australia SE5000-AUS - SE6000-AUS
Norway
SE2200 - SE6000, Norway 50Hz Available from CPU v2.10xx / v3.14xx SE2200H – SE3680H, SE4k – SE27.6k
StorEdge without Norway 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Panama
SE3000A-US - Contact SolarEdge support SE11400A-US, SE9kUS, SE10kUS, SE20kUS
Philippines
SE2200 - SE6000 Philippines 60Hz Can be connected to the following grids: 115/230V split phase (L-L connection) 220/380V WYE (L-N connection) 230/400V WYE (L-N connection) 240/420V WYE (L-N connection)
SE5k - SE27.6k Philippines 60Hz Can be connected to the following grids:
12
Supported inverters Inverter country setting Frequency Comments 220/380V WYE 230/400V WYE 240/420V WYE
SE33.3k Philippines -> Philippines 50Hz Available from CPU v3.19xx MV This inverter has a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
SE17k - SE27.6K Philippines -> 230V L-L No 60Hz Can be connected to the following grid: 230V True Delta N (requires inverter adjustment; contact SolarEdge support) SE17k limited to 10kW AC SE25K limited to 14.7kW AC SE27.6K limited to 16.2kW AC Available from CPU v3.16xx
Poland
SE2200 - SE6000, Poland 50Hz SE2200H – SE3680H, SE5k - SE27.6k
StorEdge without Poland 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Portugal
SE2200 - SE6000, Portugal 50Hz SE2200H – SE3680H, SE4k - SE27.6k
StorEdge without Portugal 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Romania
SE2200 - SE6000, Romania 50Hz SE4k - SE27.6k
StorEdge without Romania 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Seychelles
SE2200 - SE6000, Mauritius 50Hz SE4k - SE27.6k
13
Supported inverters Inverter country setting Frequency Comments
Singapore
SE2200 - SE6000, Singapore 50Hz SE2200H – SE3680H, SE4k - SE27.6k
Slovakia
SE2200 - SE6000, Slovakia -> Slovakia ZSED 50Hz Available from CPU v3.1961 SE2200H – SE3680H, Slovakia -> Slovakia SSED SE5k - SE27.6k Slovakia -> Slovakia VSD
StorEdge without Slovakia -> Slovakia ZSED 50Hz Requires StorEdge-compatible inverter and installation backup power: Slovakia -> Slovakia SSED of StorEdge Interface; refer to application note. SE2200-SE6000, Slovakia -> Slovakia VSD SE3500 AC Coupled Inverter
Slovenia
SE2200H – SE3680H, Slovenia 50Hz SE4k - SE27.6k
South Africa
SE2200 - SE6000, South Africa 50Hz SE2200H – SE3680H, SE4k - SE27.6k
SE33.3k South Africa -> South 50Hz Available from CPU v3.19xx Africa MV This inverter has a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
StorEdge without South Africa 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
StorEdge with South Africa 50Hz Available from CPU v3.18xx backup power: SE5000-ZAS - SE6000-ZAS
Spain
SE2200 - SE6000, Spain 50Hz SE2200H – SE3680H, SE4k - SE27.6k
StorEdge without Spain 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Sri Lanka
14
Supported inverters Inverter country setting Frequency Comments
SE3500, SE5000 – Sri Lanka 50Hz SE6000, SE2200H – SE3680H
St. Lucia
SE3000A-US - Caribbean -> St. Lucia 50Hz SE11400A-US
St. Vincent
SE2200 – SE4000- United Kingdom -> UK 50Hz 16A, SE4k - SE10k 230V
Sweden
SE2200 - SE6000, Sweden 50Hz SE4k - SE27.6k
StorEdge without Sweden 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Switzerland
SE2200-SE6000, Switzerland 50Hz SE4k - SE27.6k
StorEdge without Switzerland 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Tahiti
SE2200 - SE6000, Tahiti 60Hz Available from CPU v2.09xx / v3.12xx SE4k - SE27.6k
Taiwan
SE2200 - SE6000, Taiwan 60Hz SE4k - SE27.6k
SE33.3k Taiwan -> Taiwan MV 60Hz Available from CPU v3.19xx This inverter has a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
Thailand
SE5000, SE10K, Thailand -> Thailand MEA 50Hz Available from CPU v3.16xx SE25K, SE27.6K Thailand -> Thailand PEA
Turkey
SE2200 - SE6000, Turkey -> Turkey 50Hz SE2200H – SE3680H, Turkey -> N. Cyprus SE4k – SE27.6K
15
Supported inverters Inverter country setting Frequency Comments
SE33.3k Turkey -> Turkey MV 50Hz Available from CPU v3.19xx
StorEdge without Turkey -> Turkey 50Hz Requires StorEdge-compatible inverter and installation backup power: Turkey -> N. Cyprus of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
Ukraine
SE2200 – SE6000, Europe EN50438 50Hz Available from CPU v3.16xx SE4k - SE27.6k
StorEdge without Europe EN50438 50Hz Requires StorEdge-compatible inverter and installation backup power: of StorEdge Interface; refer to application note. SE2200-SE6000, SE3500 AC Coupled Inverter
United Kingdom
SE2200 - SE6000, United Kingdom -> GBR 50Hz N. Ireland setting available from CPU v2.10xx / v3.14xx SE2200H – SE3680H, United Kingdom -> N. GBR setting available from CPU v3.16xx; in earlier SE4k - SE27.6k Ireland versions use UK 230V
SE33.3k United Kingdom -> UK 480 50Hz This inverter has a 277/480Vac output voltage and is designed for connection to the medium voltage grid via a transformer
StorEdge without United Kingdom -> GBR 50Hz Requires StorEdge-compatible inverter and installation backup power: United Kingdom -> N. of StorEdge Interface; refer to application note. SE2200-SE6000, Ireland SE3500 AC Coupled Inverter
United States (including Guam, Puerto Rico and US Virgin Islands, excluding Hawaii and New York)
SE3000A-US - USA -> Auto 60Hz Refer to the inverter datasheet for full inverter-grid SE11400A-US USA -> 240V compatibility: USA -> 240V No Neutral http://www.solaredge.us/files/pdfs/products/inverters/ se-single-phase-us-inverter-datasheet.pdf USA -> 208V Rule 21 setting available from CPU v3.16xx USA -> 208V No Neutral
Rule 21 -> Auto Rule 21 -> 240V Rule 21 -> 240V No Neutral Rule 21 -> 208V Rule 21 -> 208V No Neutral
SE9kUS, SE14.4kUS USA -> 208V 60Hz 120/208V WYE grid or 208V Delta grid (SE9kUS delta Rule 21 -> 208V grid support for inverters with part number SE9K- US228NNU4) Rule 21 setting available from CPU v3.16xx
SE10kUS, SE20KUS, USA -> 277V 60Hz 277/480V WYE grid only SE33.3kUS
16
Supported inverters Inverter country setting Frequency Comments Rule 21 -> 277V Rule 21 setting available from CPU v3.16xx Puerto Rico 277V Puerto Rico setting available from CPU v3.19xx
SE7600A-USS USA -> Auto 60Hz Available from CPU v3.18xx (StorEdge inverter) USA -> 240V
United States (Hawaii only)
SE3000A-US - Hawaii -> XXX Auto 60Hz Refer to the inverter datasheet for full inverter-grid SE11400A-US Hawaii -> XXX 240V compatibility: Hawaii -> XXX 240V No http://www.solaredge.us/files/pdfs/products/inverters/ Neutral se-single-phase-us-inverter-datasheet.pdf Hawaii -> XXX 208V Use Hawaii settings for HECO grid settings Hawaii -> XXX 208V No Molokai and Lanai setting available from CPU v2.10xx / Neutral v3.14xx XXX = Hawaii / Kauai / Molokai and Lanai
SE9kUS, SE14.4KUS Hawaii -> XXX 208V 60Hz 120/208V WYE grid or 208V Delta grid (SE9kUS delta XXX = Hawaii / Kauai / grid support for inverters with part number SE9K- Molokai and Lanai US228NNU4) Use Hawaii settings for HECO grid settings Molokai and Lanai setting available from CPU v2.10xx / v3.14xx
SE10kUS, SE20KUS, Hawaii -> XXX 277V 60Hz 277/480V WYE grid only SE33.3kUS XXX = Hawaii / Kauai / Use Hawaii settings for HECO grid settings Molokai and Lanai Molokai and Lanai setting available from CPU v2.10xx / v3.14xx
SE7600A-USS Hawaii -> XXX Auto 60Hz Use Hawaii settings for HECO grid settings (StorEdge inverter) Hawaii -> XXX 240V Available from CPU v3.18xx Hawaii -> XXX 240V No Neutral XXX = Hawaii / Kauai / Molokai and Lanai
United States (New York only)
SE3000A-US - NY -> New-York Auto 60Hz Refer to the inverter datasheet for full inverter-grid SE11400A-US NY -> New-York 240V compatibility: NY -> New-York 240V No http://www.solaredge.us/files/pdfs/products/inverters/ Neutral se-single-phase-us-inverter-datasheet.pdf NY -> New-York 208V Available from CPU v2.10xx / v3.14xx NY -> New-York 208V No Neutral
SE9kUS, SE14.4KUS NY -> New-York 208V 60Hz 120/208V WYE grid or 208V Delta grid (SE9kUS delta grid support for inverters with part number SE9K- US228NNU4) Available from CPU v2.10xx / v3.14xx
17
Supported inverters Inverter country setting Frequency Comments
SE10kUS, SE20KUS, NY -> New-York 277V 60Hz 277/480V WYE grid only SE33.3kUS Available from CPU v2.10xx / v3.14xx
SE7600A-USS NY -> New-York Auto 60Hz Available from CPU v3.18xx (StorEdge inverter) NY -> New-York 240V NY -> New-York 240V No Neutral
Zimbabwe
SE2200 - SE6000, Zimbabwe 50Hz Available from CPU v3.16xx SE4k – SE27.6k
18