Ptychography and Related Diffractive Imaging Methods J.M. RODENBURG1

Total Page:16

File Type:pdf, Size:1020Kb

Ptychography and Related Diffractive Imaging Methods J.M. RODENBURG1 aiep v.2005/11/15 Prn:6/12/2007; 13:13 F:aiep1503.tex; VTEX/JOL p. 1 aid: 3 pii: S1076-5670(07)00003-1 docsubty: REV ADVANCES IN IMAGING AND ELECTRON PHYSICS, VOL. 150 1 1 2 2 3 Ptychography and Related Diffractive Imaging Methods 3 4 4 5 5 6 J.M. RODENBURG1 6 7 7 8 1Department of Electronic and Electrical Engineering, University of Sheffield, Mappin Street, 8 9 S1 3JD, United Kingdom 9 10 10 11 11 12 I. Introduction . 87 12 13 II. Ptychography in Context . 88 13 A. History . 88 14 14 B. The Relative Strength of Diffractive and Imaging Methods . 93 15 C. The Definition of Ptychography . 94 15 16 D. A Qualitative Description of Ptychography . 97 16 17 E. Mathematical Formulation of Crystalline STEM Ptychography . 103 17 18 F. Illumination of a “Top Hat” or Objects with Finite Support . 109 18 G. Two-Beam Ptychography . 113 19 19 H. Commentary on Nyquist Sampling . 114 20 I. Concluding Remarks on Classical Ptychography . 117 20 21 III. Coordinates, Nomenclature, and Scattering Approximations . 119 21 22 A. Geometry of the Two-Dimensional, Small-Angle Approximation . 119 22 23 B. Three-Dimensional Geometry . 123 23 C. Dynamical Scattering . 132 24 24 IV. The Variants: Data, Data Processing, and Experimental Results . 138 25 A. The Line Scan Subset . 140 25 26 B. The Bragg–Brentano Subset: Projection Achromatic Imaging . 149 26 27 C. Ptychographical Iterative (Pi) Phase-Retrieval Reconstruction . 163 27 28 D. The Wigner Distribution Deconvolution Method . 172 28 V. Conclusions . 178 29 29 References . 180 30 30 31 31 32 32 33 I. INTRODUCTION 33 34 34 35 Ptychography is a nonholographic solution of the phase problem. It is a 35 36 method of calculating the phase relationships between different parts of a 36 37 scattered wave disturbance in a situation where only the magnitude (intensity 37 38 or flux) of the wave can be physically measured. Its usefulness lies in its ability 38 39 (like holography) to obtain images without the use of lenses, and hence to lead 39 40 to resolution improvements and access to properties of the scattering medium 40 41 (such as the phase changes introduced by the object) that cannot be easily 41 42 obtained from conventional imaging methods. Unlike holography, it does not 42 87 ISSN 1076-5670 Copyright 2008, Elsevier Inc. DOI: 10.1016/S1076-5670(07)00003-1 All rights reserved. aiep v.2005/11/15 Prn:6/12/2007; 13:13 F:aiep1503.tex; VTEX/JOL p. 2 aid: 3 pii: S1076-5670(07)00003-1 docsubty: REV 88 RODENBURG 1 need a stable reference wave; the only interferometer used in ptychography is 1 2 diffraction interference occurring in the object itself. 2 3 The concept of ptychography was originated by the late Walter Hoppe 3 4 between about 1968 and 1973 (Hoppe, 1969a, 1969b; Hoppe and Strube, 4 5 1969; Hegerl and Hoppe, 1970, 1972). In its original formulation it was 5 6 difficult to contemplate how to implement an actual experimental proof of 6 7 the idea at short (atomic scale) wavelengths, other than for a crystalline object 7 8 in a scanning transmission electron microscope (STEM). Hoppe and Strube 8 9 (1969) demonstrated the idea experimentally using visible light optics, but at 9 10 the time that Hoppe was thinking about these ideas, STEMs were simply not 10 11 sufficiently developed (particularly the detectors available) to undertake the 11 12 necessary measurements. At that time, the benefits of the technique were ill 12 13 defined and offered no clear improvements over existing imaging, diffraction, 13 14 and holographic methods. In fact, when a proof of principle was eventually 14 15 established by Nellist et al. (1995), it was discovered that ptychography did 15 16 have one uniquely and profoundly important advantage over all other phase- 16 17 retrieval or imaging techniques: it is not subject to the limitations of the 17 18 coherence envelope (the “information limit”), which today is still regarded 18 19 as the last hurdle in optimal electron imaging. 19 20 In view of the recent advances in iterative solution of the ptychographic 20 21 data set (see Section IV.C) and their experimental implementation in visible 21 22 light optics and hard X-ray imaging, a review of the neglected strengths of 22 23 the ptychographical principle is of benefit. Recent years have seen a growing 23 24 interest in iterative solutions of the phase problem. In most modern work, 24 25 Hoppe’s pioneering thoughts have been entirely neglected. This is unfortunate 25 26 for two reasons. First is the scholarly misrepresentation of the precedence of 26 27 certain key ideas in the history of the field of phase problems. Second, a true 27 28 appreciation of what ptychography encompasses, especially with respect to 28 29 “conventional” diffractive imaging methods, means that a great opportunity 29 30 has yet to be fully exploited. This Chapter attempts to demonstrate these 30 advantages are and why this Cinderella of the phase-retrieval story may be 31 31 on the brink of revolutionizing short-wavelength imaging science. 32 32 33 33 34 II. PTYCHOGRAPHY IN CONTEXT 34 35 35 36 This section places ptychography in the context of other phase-retrieval 36 37 methods in both historical and conceptual terms. 37 38 38 39 A. History 39 40 40 41 Recovery of the lost phase (or relative phase) by some calculation method 41 42 is still considered a problem because when these issues were first addressed 42 aiep v.2005/11/15 Prn:6/12/2007; 13:13 F:aiep1503.tex; VTEX/JOL p. 3 aid: 3 pii: S1076-5670(07)00003-1 docsubty: REV PTYCHOGRAPHY AND RELATED DIFFRACTIVE IMAGING METHODS 89 1 (before World War II), it appeared that in certain scattering geometries 1 2 (especially those most easily accessible experimentally) a solution could not 2 3 exist, and if it did exist, it would be very ill conditioned mathematically. X-ray 3 4 crystallography was the first experimental discipline to admit to the conse- 4 5 quences of lost phase. In fact, given that large quantities of stereochemical a 5 6 priori information is often available, the crystalline diffraction phase problem 6 7 is much more tractable than the generalized phase problem. Indeed, it could 7 8 be argued that Watson and Crick’s discovery of the structure of DNA (Watson 8 9 and Crick, 1953) was itself an ad hoc solution to a phase problem – they had 9 10 access to the intensity of the scattered X-ray diffraction pattern from a crystal 10 11 composed of DNA molecules and essentially found a “solution” (a physical 11 12 distribution of atoms) that was consistent with that intensity and with the 12 13 known stereochemistry constraints of the constituent amino acids. This use 13 14 of a priori information is an important characteristic of all solutions to the 14 15 phase problem. 15 16 The key advantage of phase-retrieval methods in the context of imaging is 16 17 that image formation can be unshackled from the difficulties associated with 17 18 the manufacture of high-quality lenses of large numerical aperture. In some 18 19 fields, such as stellar interferometry (Michelson, 1890), it is only possible to 19 20 record a property related to the intensity of the Fourier transform of the object. 20 21 The creation of an image from these data is then a classic phase problem 21 22 (in this case, rather easily solvable given that the a priori information that 22 23 the object in question is finite, of positive intensity, and is situated on an 23 24 empty background). In the field of visible wavelength optical microscopy, 24 25 little need exists to solve the phase problem because very good lenses of very 25 26 large numerical aperture can be relatively easily manufactured (although a 26 27 phase problem still exists in the sense that the image itself is recorded only in 27 28 intensity). For short-wavelength microscopies (using X-rays or high-energy 28 29 electrons), good-quality lenses are not easily manufactured. For example, the 29 30 field of electron imaging has recently seen great progress in the manufacture 30 31 of non-round lenses correctors (for which spherical aberration need not be 31 32 positive, as with a round magnetic lens), a scheme first proposed by Scherzer 32 33 (1947) but which has only recently become feasible with the advent of 33 34 powerful inexpensive computers that can be interfaced to very high-stability 34 35 power supplies. However, the cost of such systems is high (typically of the 35 36 order of $1000 per corrector), and the gains in resolution over existing round 36 37 magnetic lenses are only of an order of a factor of 2 or so. In the case of 37 38 X-ray microscopy, the zone plate remains the predominant lens technology, 38 39 but this technology requires manufacturing precision of at least the final 39 40 requisite resolution of the lens itself; making a sufficiently thick zone plate 40 41 with very high lateral definition (< 50 nm) difficult, especially for hard X- 41 42 rays. For example, compare the best resolution obtainable from such a lens 42 aiep v.2005/11/15 Prn:6/12/2007; 13:13 F:aiep1503.tex; VTEX/JOL p. 4 aid: 3 pii: S1076-5670(07)00003-1 docsubty: REV 90 RODENBURG 1 (also 50 nm) with the “resolution” of conventional X-ray diffraction using 1 ∼ 2 the same wavelength; notwithstanding the fact that the object of interest (the 2 3 unit cell) must be amenable to crystallization, the effective resolution of the 3 4 “image” (an estimate of that unit cell) is roughly the same as the wavelength: 4 5 0.1 nm.
Recommended publications
  • Optical Ptychographic Phase Tomography
    University College London Final year project Optical Ptychographic Phase Tomography Supervisors: Author: Prof. Ian Robinson Qiaoen Luo Dr. Fucai Zhang March 20, 2013 Abstract The possibility of combining ptychographic iterative phase retrieval and computerised tomography using optical waves was investigated in this report. The theoretical background and historic developments of ptychographic phase retrieval was reviewed in the first part of the report. A simple review of the principles behind computerised tomography was given with 2D and 3D simulations in the following chapters. The sample used in the experiment is a glass tube with its outer wall glued with glass microspheres. The tube has a diameter of approx- imately 1 mm and the microspheres have a diameter of 30 µm. The experiment demonstrated the successful recovery of features of the sam- ple with limited resolution. The results could be improved in future attempts. In addition, phase unwrapping techniques were compared and evaluated in the report. This technique could retrieve the three dimensional refractive index distribution of an optical component (ideally a cylindrical object) such as an opitcal fibre. As it is relatively an inexpensive and readily available set-up compared to X-ray phase tomography, the technique can have a promising future for application at large scale. Contents List of Figures i 1 Introduction 1 2 Theory 3 2.1 Phase Retrieval . .3 2.1.1 Phase Problem . .3 2.1.2 The Importance of Phase . .5 2.1.3 Phase Retrieval Iterative Algorithms . .7 2.2 Ptychography . .9 2.2.1 Ptychography Principle . .9 2.2.2 Ptychographic Iterative Engine .
    [Show full text]
  • Wide-Field, High-Resolution Fourier Ptychographic Microscopy
    Wide-field, high-resolution Fourier ptychographic microscopy Guoan Zheng*, Roarke Horstmeyer, and Changhuei Yang Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA *Correspondence should be addressed to: [email protected] Keywords: Ptychography; high-throughput imaging; digital wavefront correction; digital pathology Manuscript information: 11 text pages, 4 figures Supporting materials: 2 text pages, 8 figures, 1 video Abstract: In this article, we report an imaging method, termed Fourier ptychographic microscopy (FPM), which iteratively stitches together a number of variably illuminated, low-resolution intensity images in Fourier space to produce a wide-field, high-resolution complex sample image. By adopting a wavefront correction strategy, the FPM method can also correct for aberrations and digitally extend a microscope's depth-of-focus beyond the physical limitations of its optics. As a demonstration, we built a microscope prototype with a resolution of 0.78 μm, a field-of-view of approximately 120 mm2, and a resolution-invariant depth-of-focus of 0.3 mm (characterized at 632 nm). Gigapixel color images of histology slides verify FPM's successful operation. The reported imaging procedure transforms the general challenge of high-throughput, high- resolution microscopy from one that is coupled to the physical limitations of the system's optics to one that is solvable through computation. The throughput of an imaging platform is fundamentally limited by its optical system’s space- bandwidth product (SBP)1, defined as the number of degrees of freedom it can extract from an optical signal. The SBP of a conventional microscope platform is typically in megapixels, regardless of its employed magnification factor or numerical aperture (NA).
    [Show full text]
  • Electron Ptychography Achieves Atomic-Resolution Limits Set by Lattice Vibrations
    Electron ptychography achieves atomic-resolution limits set by lattice vibrations Zhen Chen1*, Yi Jiang2, Yu-Tsun Shao1, Megan E. Holtz3, Michal Odstrčil4†, Manuel Guizar- Sicairos4, Isabelle Hanke5, Steffen Ganschow5, Darrell G. Schlom3,5,6, David A. Muller1,6* 1School of Applied and Engineering Physics, Cornell University, Ithaca, NY 14853, USA 2Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA 3Department of Materials Science and Engineering, Cornell University, Ithaca, NY, USA 4Paul Scherrer Institut, 5232 Villigen PSI, Switzerland 5Leibniz-Institut für Kristallzüchtung, Max-Born-Str. 2, 12489 Berlin, Germany 6Kavli Institute at Cornell for Nanoscale Science, Ithaca, NY, USA * Correspondence to: [email protected] (Z.C.); [email protected] (D.A.M.) †Present address: Carl Zeiss SMT, Carl-Zeiss-Straße 22, 73447 Oberkochen, Germany Abstract: Transmission electron microscopes use electrons with wavelengths of a few picometers, potentially capable of imaging individual atoms in solids at a resolution ultimately set by the intrinsic size of an atom. Unfortunately, due to imperfections in the imaging lenses and multiple scattering of electrons in the sample, the image resolution reached is 3 to 10 times worse. Here, by inversely solving the multiple scattering problem and overcoming the aberrations of the electron probe using electron ptychography to recover a linear phase response in thick samples, we demonstrate an instrumental blurring of under 20 picometers. The widths of atomic columns in the measured electrostatic potential are now no longer limited by the imaging system, but instead by the thermal fluctuations of the atoms. We also demonstrate that electron ptychography can potentially reach a sub-nanometer depth resolution and locate embedded atomic dopants in all three dimensions with only a single projection measurement.
    [Show full text]
  • Near-Field Fourier Ptychography: Super- Resolution Phase Retrieval Via Speckle Illumination
    Near-field Fourier ptychography: super- resolution phase retrieval via speckle illumination HE ZHANG,1,4,6 SHAOWEI JIANG,1,6 JUN LIAO,1 JUNJING DENG,3 JIAN LIU,4 YONGBING ZHANG,5 AND GUOAN ZHENG1,2,* 1Biomedical Engineering, University of Connecticut, Storrs, CT, 06269, USA 2Electrical and Computer Engineering, University of Connecticut, Storrs, CT, 06269, USA 3Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439, USA. 4Ultra-Precision Optoelectronic Instrument Engineering Center, Harbin Institute of Technology, Harbin 150001, China 5Shenzhen Key Lab of Broadband Network and Multimedia, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China 6These authors contributed equally to this work *[email protected] Abstract: Achieving high spatial resolution is the goal of many imaging systems. Designing a high-resolution lens with diffraction-limited performance over a large field of view remains a difficult task in imaging system design. On the other hand, creating a complex speckle pattern with wavelength-limited spatial features is effortless and can be implemented via a simple random diffuser. With this observation and inspired by the concept of near-field ptychography, we report a new imaging modality, termed near-field Fourier ptychography, for tackling high- resolution imaging challenges in both microscopic and macroscopic imaging settings. The meaning of ‘near-field’ is referred to placing the object at a short defocus distance with a large Fresnel number. In our implementations, we project a speckle pattern with fine spatial features on the object instead of directly resolving the spatial features via a high-resolution lens. We then translate the object (or speckle) to different positions and acquire the corresponding images using a low-resolution lens.
    [Show full text]
  • Coherent Diffraction Imaging
    Coherent Diffraction Imaging Ian Robinson London Centre for Nanotechnology Felisa Berenguer Diamond Light Source Ross Harder Richard Bean Structural Biology Moyu Watari Oxford University March 2009 I. K. Robinson, STRUBI Mar 2009 1 Outline • Imaging with X-rays • Coherence based imaging • Nanocrystal structures • Extension to phase objects • Exploration of crystal strain • Biological imaging by CXD I. K. Robinson, STRUBI Mar 2009 2 Types of Full-Field Microscopy (Y. Chu) X-ray Topography Projection Imaging, Tomography, PCI Miao et al (1999) Coherent X-ray Diffraction Coherent Diffraction imaging Transmission Full-Field MicroscopyI. K. Robinson, STRUBI Mar 2009 3 Full-Field Diffraction Microscopy Lensless X-ray “Microscope” APS ξHOR= 20µm, focus to 1µm NSLS-II ξHOR= 500µm, focus to 0.05µm I. K. Robinson, STRUBI Mar 2009 4 Longitudinal Coherence Als-Nielsen and McMorrow (2001) I. K. Robinson, STRUBI Mar 2009 5 Lateral (Transverse) Coherence Als-Nielsen and McMorrow (2001) I. K. Robinson, STRUBI Mar 2009 6 Smallest Beam using Slits (9keV) 10 Beam 100mm away size (micron) 50mm away 20mm away 10mm away 0 0 10 Slit size (micron) I. K. Robinson, STRUBI Mar 2009 7 Fresnel Diffraction when d2~λD X-ray beam defined by RB slits Visible Fresnel diffraction from Hecht “Optics” I. K. Robinson, STRUBI Mar 2009 8 Diffuse Scattering acquires fine structure with a Coherent Beam I. K. Robinson, STRUBI Mar 2009 9 Coherent Diffraction from Crystals k Fourier Transform h I. K. Robinson, STRUBI Mar 2009 10 I. K. Robinson, STRUBI Mar 2009 11 Chemical Synthesis of Nanocrystals • Reactants introduced rapidly • High temperature solvent • Surfactant/organic capping agent • Square superlattice (200nm scale) C.
    [Show full text]
  • Coherent Diffraction Imaging
    Coherent Diffraction Imaging Ross Harder aka “The Imposter” Acknowledgments: Prof. Ian Robinson (BNL) 34-ID-C Dr. Xiaojing Huang (BNL) Advanced Photon Source Dr. Jesse Clark (PULSE institute, SLAC Amazon) Prof. Oleg Shpyrko (UCSD) Dr. Andrew Ulvestad (ANL – MSDTesla) https://tinyurl.com/y2qtrz7c Dr. Ian McNulty (ANL – CNM MaxIV) Dr. Junjing Deng (ANL – APS) Non-compact samples (Ptychography) Compact Objects (CDI) research papers implies an effective degree of transverse coherence at the oftenCOHERENCE associated with interference phenomena, where the source, as totally incoherent sources radiate into all directions mutual coherence function (MCF)1 (Goodman, 1985). À r ; r ; E à r ; t E r ; t 2 The transverse coherence area ÁxÁy of a synchrotron ð 1 2 Þ¼ ð 1 Þ ð 2 þ Þ ð Þ source can be estimated from Heisenberg’s uncertainty prin- plays the main role. It describes the correlations between two ciple (Mandel & Wolf, 1995), ÁxÁy h- 2=4Áp Áp , where x y complex values of the electric field E à r1; t and E r2; t at Áx; Áy and Áp ; Áp are the uncertainties in the position and ð Þ ð þ Þ x y different points r1 and r2 and different times t and t .The momentum in the horizontal and vertical direction, respec- brackets denote the time average. þ tively. Due to the de Broglie relation p = h- k,wherek =2=, Whenh weÁÁÁ consideri propagation of the correlation function the uncertainty in the momentum Áp can be associated with of the field in free space, it is convenient to introduce the the source divergence Á, Áp = h- kÁ,andthecoherencearea cross-spectral density function (CSD), W r1; r2; ! , which is in the source plane is given by defined as the Fourier transform of the MCFð (MandelÞ & Wolf, 1995), 2 1 ÁxÁy : 1 4 Á Á ð Þ W r1; r2; ! À r1; r2; exp i! d; 3 x y ð Þ¼ ð Þ ðÀ Þ ð Þ where ! Visibilityis the frequency of fringes is of a the direct radiation.
    [Show full text]
  • Research on the Application of Vortex Beam in Ptychography
    Research on the Application of Vortex Beam in Ptychography CHEN JIE MSc (by research) University of York Physics October 2020 Abstract Ptychography is a coherent diffraction technology, which is not limited by sam- ple size and has the advantages of high imaging quality, strong portability, and low stability requirements for optical platform. It has been experimen- tally confirmed in the visible light domain, X-ray and other different frequency bands. The ptychography system has a wide application prospect in the fields of microimaging, three-dimensional morphology measurement and information security. However, many researches on ptychography are still in the prelimi- nary theoretical stage and there is none research on its combination with vortex beam, and the key parameters affecting the imaging performance are still not to be studied. This thesis first briefly introduces the research background, sig- nificance, the basic concepts, development and application of ptychography and vortex beam. Then, it introduces the theoretical basis supporting its use, in- cluding computer-generated hologram (CGH), beam steering and the computing algorithm of ptychography. On this basis, this thesis presents the following in- novative research: An optical ptychography set-up, with a spatial light modulator as the core de- vice, is designed to facilitate the flexible production of different types of optical probe, such as the generation of conventional beams and vortex beams; flexible adjustment of the order and defocus of vortex beams, etc., so as to realize their experimental exploration. Experiments show that vortex beams have a higher imaging quality in ptychography, and the topological charge number and defo- cus of vortices also affect the reconstruction quality of the samples to a certain extent.
    [Show full text]
  • This Is a Repository Copy of Ptychography. White Rose
    This is a repository copy of Ptychography. White Rose Research Online URL for this paper: http://eprints.whiterose.ac.uk/127795/ Version: Accepted Version Book Section: Rodenburg, J.M. orcid.org/0000-0002-1059-8179 and Maiden, A.M. (2019) Ptychography. In: Hawkes, P.W. and Spence, J.C.H., (eds.) Springer Handbook of Microscopy. Springer Handbooks . Springer . ISBN 9783030000684 https://doi.org/10.1007/978-3-030-00069-1_17 This is a post-peer-review, pre-copyedit version of a chapter published in Hawkes P.W., Spence J.C.H. (eds) Springer Handbook of Microscopy. The final authenticated version is available online at: https://doi.org/10.1007/978-3-030-00069-1_17. Reuse Items deposited in White Rose Research Online are protected by copyright, with all rights reserved unless indicated otherwise. They may be downloaded and/or printed for private study, or other acts as permitted by national copyright laws. The publisher or other rights holders may allow further reproduction and re-use of the full text version. This is indicated by the licence information on the White Rose Research Online record for the item. Takedown If you consider content in White Rose Research Online to be in breach of UK law, please notify us by emailing [email protected] including the URL of the record and the reason for the withdrawal request. [email protected] https://eprints.whiterose.ac.uk/ Ptychography John Rodenburg and Andy Maiden Abstract: Ptychography is a computational imaging technique. A detector records an extensive data set consisting of many inference patterns obtained as an object is displaced to various positions relative to an illumination field.
    [Show full text]
  • X-Ray Linear Dichroic Ptychography
    X-ray linear dichroic ptychography Yuan Hung Loa,b,c,d, Jihan Zhoua,b,c, Arjun Ranaa,b,c, Drew Morrillb,e,f, Christian Gentryb,e,f, Bjoern Endersg, Young-Sang Yuh, Chang-Yu Suni, David A. Shapiroh, Roger W. Falconeb,h,j, Henry C. Kapteynb,e,f, Margaret M. Murnaneb,e,f, Pupa U. P. A. Gilberti,k,l,m,n, and Jianwei Miaoa,b,c,1 aDepartment of Physics and Astronomy, University of California, Los Angeles, CA 90095; bSTROBE NSF Science and Technology Center, University of Colorado Boulder, Boulder, CO 80309; cCalifornia NanoSystems Institute, University of California, Los Angeles, CA 90095; dDepartment of Bioengineering, University of California, Los Angeles, CA 90095; eJILA, University of Colorado Boulder and National Institute of Standards and Technology, Boulder, CO 80309; fDepartment of Physics, University of Colorado Boulder, Boulder, CO 80309; gNational Energy Research Scientific Computing Center, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 hAdvanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720; iDepartment of Physics, University of Wisconsin, Madison, WI 53706; jDepartment of Physics, University of California, Berkeley, CA, 94720; kDepartment of Chemistry, University of Wisconsin, Madison, WI 53706; lDepartment of Materials Science and Engineering, University of Wisconsin, Madison, WI 53706; mDepartment of Geoscience, University of Wisconsin, Madison, WI 53706; and nChemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 Edited by David A. Weitz, Harvard University,
    [Show full text]
  • X-Ray Ptychography Performed for First Time at Small-Scale Laboratory 12 May 2021
    X-ray ptychography performed for first time at small-scale laboratory 12 May 2021 The team from Diamond Light Source, Ghent University, University of Sheffield, and University College London conducted an experiment with a compact liquid metal-jet (LMJ) X-ray source. Laboratory X-ray sources have significantly lower levels of brilliance but currently provide the X-ray synchrotron user community with access to micro- CT, where they can gain a great deal of experience and produce preliminary data, at their home institutions. Until now, no such equivalent has existed for nano-scale imaging through coherent diffraction imaging and ptychography. The team's paper outlines such an experiment and the first proof of concept for far field X-ray ptychography performed using an X-ray laboratory source. Diamond science group leader, Paul Quinn comments "We have been leading developments in ptychography to open this technique to new science areas and communities. It builds on the The SMALL laboratory at the University of Sheffield work we've done over many years and, longer term being prepared for the ptychographic imaging this approach in particular has real potential to experiment with the installation of the portable end provide higher resolution imaging to lab source station designed at I13-1 of Diamond Light Source and facilities." the SLcam hyperspectral detector from Ghent University. Credit: Dr Parnell, University of Sheffield In recent years, X-ray ptychography has revolutionized nanoscale phase contrast imaging at large-scale synchrotron sources. The technique produces quantitative phase images with the highest possible spatial resolutions (10's nm) – going well beyond the conventional limitations of the available X-ray optics—and has wide reaching applications across the physical and life sciences.
    [Show full text]
  • Wavefront Imaging Sensor with High Resolution and Depth Ranging
    WISHED: Wavefront imaging sensor with high resolution and depth ranging Yicheng Wu∗, Fengqiang Li∗, Florian Willomitzer, Ashok Veeraraghavan, Oliver Cossairt Abstract—Phase-retrieval based wavefront sensors have been shown to reconstruct the complex field from an object with a high spatial resolution. Although the reconstructed complex field encodes the depth information of the object, it is impractical to be used as a depth sensor for macroscopic objects, since the unambiguous depth imaging range is limited by the optical wavelength. To improve the depth range of imaging and handle depth discontinuities, we propose a novel three-dimensional sensor by leveraging wavelength diversity and wavefront sensing. Complex fields at two optical wavelengths are recorded, and a synthetic wavelength can be generated by correlating those wavefronts. The proposed system achieves high lateral and depth resolutions. Our experimental prototype shows an unambiguous range of more than 1,000× larger compared with the optical wavelengths, while the depth precision is up to 9µm for smooth objects and up to 69µm for rough objects. We experimentally demonstrate 3D reconstructions for transparent, translucent, and opaque objects with smooth and rough surfaces. Index Terms—3D imaging, Wavelength diversity, Wavefront sensing, Phase retrieval F 1 INTRODUCTION Ptical fields from an object contain information about for any WFS technique so that none can be used as a general O both albedo and depth. However, intensity-based purpose. CCD/CMOS sensors can only record the amplitude of a The goal of this work is to develop a wavefront sensor complex optical field. capable of measuring the depth of objects with large surface In order to reconstruct a complex-valued optical field variations (orders of magnitude larger than optical wave- that contains both amplitude and phase information, wave- lengths) and objects with rough surfaces.
    [Show full text]
  • Deep Sub-Εngstrom Imaging of 2D Materials with a High Dynamic
    Deep sub-Ångstrom imaging of 2D materials with a high dynamic range detector Yi Jiang*1, Zhen Chen*2, Yimo Han2, Pratiti Deb1,2, Hui Gao3,4, Saien Xie2,3, Prafull Purohit1, Mark W. Tate1, Jiwoong Park3, Sol M. Gruner1,5, Veit Elser1, David A. Muller2,5 1. Department of Physics, Cornell University, Ithaca, NY 14853, USA 2. School of Applied and Engineering Physics, Cornell University, Ithaca, NY 14853, USA 3. Department of Chemistry, Institute for Molecular Engineering, and James Franck Institute, University of Chicago, Chicago, IL 60637, USA 4. Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853, USA 5. Kavli Institute at Cornell for Nanoscale Science, Ithaca, NY 14853, USA ABSTRACT Aberration-corrected optics have made electron microscopy at atomic-resolution a widespread and often essential tool for nanocharacterization. Image resolution is dominated by beam energy and the numerical aperture of the lens (α), with state-of-the-art reaching ~0.47 Å at 300 keV. Two-dimensional materials are imaged at lower beam energies to avoid knock-on damage, limiting spatial resolution to ~1 Å. Here, by combining a new electron microscope pixel array detector with the dynamic range to record the complete distribution of transmitted electrons and full-field ptychography to recover phase information from the full phase space, we increased the spatial resolution well beyond the traditional lens limitations. At 80 keV beam energy, our ptychographic reconstructions significantly improved image contrast of single-atom defects in MoS2, reaching an information limit close to 5α, corresponding to a 0.39 Å Abbe resolution, at the same dose and imaging conditions where conventional imaging modes reach only 0.98 Å.
    [Show full text]