Download an Order Form

Total Page:16

File Type:pdf, Size:1020Kb

Download an Order Form ElEctrical GEnEratinG SyStEmS Association 1650 South Dixie Highway, Suite 400 Years of S 50 erv ice Boca Raton FL 33432 to t h ry e O st n- du Site Power In Denver, CO Denver, Fairbanks Morse Engine Member Profile Member Engine Morse Fairbanks EGSA Celebrates 50 Years in in Years 50 Celebrates EGSA Continuity and Customer Service Customer and Continuity Preview: Business Ensures Life Vantis Time Capsule Interviews Capsule Time Standby Engines In Data Centers Data In Engines Standby Diesel for Requirements EPA 2015 July/August $5.00 The long-awaited 5th Edition of On-Site Power Generation: A Comprehensive Guide to On-Site Power is available for distribution and purchase! Newly Revised & Expanded FIFTH EDITION with Soft Cover The Book is in Stock! The 5th Edition represents a major improvement over the 4th Edition! Order Your Here are a few reasons why: Copy Today! • Soft cover vs. hard cover - lighter and easier to carry Published by the Electrical • Over 700 pages vs. 600 pages (more than 100 pages added since the 4th Edition) Generating Systems Association • 47 chapters vs. 39 chapters (10 new subjects!) If you are in the business of On-Site Power, you should own a copy! This is THE On-Site Power Generation book. It is all there. It’s all in one place. Powerline • July/August 2015 Call (561) 750-5575 or visit EGSA.org to download an order form. www.EGSA.org 2 COnTEnTS Volume 50, No.4 • July/August 2015 Columns From the Top . 7 Benchmarking 50 Years! Maintaining the Focus. Education . 8 Education Update. Codes & Standards . 10 Features It’s ‘High Time for Power’ this September in Denver! . 12 Won’t You Join EGSA as We Continue the Celebration of Our 50th Year? EPA Requirements for Diesel Standby Engines In Data Centers . 16 EGSA 50th Anniversary Time Capsule Interviews . 24 On the Cover: Looking Back on 50 Years. It’s ‘High Time for Power’ this September in Denver!; Page 12 Vantis Life Ensures Business Continuity and Customer Service . 38 2015 TOYA . 42 Fairbanks Morse Engine Member Profile . 48 Another in our series of EGSA Member company profiles. Departments Events Calendar . 5 Association and Industry events. Index of Advertisers . 6 Who’s Who in this issue of Powerline. Association News . 44 Updates from EGSA. EGSA Membership Application . 45 EGSA 50th Anniversary It pays to be a Member of EGSA. Join now! Time Capsule Interviews: Looking Back on 50 Years; Page 24. EGSA New Members . 47 Who has joined EGSA in the past few months? Job Bank . 50 Looking for a new job? Industry News . 55 The latest reports. Powerline • July/August 2015 www.EGSA.org 3 Data Centers, Hospitals, Critical Care Centers, Nursing Homes, Grocery Stores, Climate-Controlled Storage Facilities, First Responder Facilities… Increase your generator run time by as much as 400% BECAUSE YOU NEVER KNOW WHEN GTI Bi-Fuel® — A Product YOU’LL NEED STANDBY POWER. of the HOERBIGER Group Limited diesel fuel storage and irregular re-supply can often cut emergency generator run time to 24 hours or less. The GTI Bi-Fuel® System can increase your run time by as much as four times that of conventional, all-diesel operation. GTI BI-FUEL IS THE SOLUTION This patented system draws low-pressure natural gas into your diesel engine as supplemental fuel. It can substitute up to 70% of your diesel fuel requirement, extending generator run time and reducing your dependence on diesel fuel re-supply. Proven in thousands of installations, GTI Bi-Fuel® is an easy retrofit requiring no engine modification. Find a distributor near you or learn more about GTI Bi-Fuel® at www.gti-altronic.com. Powerline • July/August 2015 www.EGSA.org 4 EVEnTS CALEnDAR Conferences EGSA 2015 George Rowley Schools of EGSA 2015 Fall Conference On-Site Power Generation September 13-15, 2015; Denver, CO The most complete overview of an On-Site Power Generation Sys- Join us as we continue EGSA’s 50th Anniversary celebration at tem available. Gain valuable Continuing Education Units (CEUs) the Annual Fall Conference. EGSA’s Annual Fall Conference fea- by applying today! For information, visit www.EGSA.org or call tures educational sessions on a broad range of issues impacting (561) 750-5575. today’s On-Site Power Industry. More information is available at Basic Schools www.EGSA.org/fall or by calling (561) 750-5575. February 10-12 ........................................................Scottsdale, AZ June 2-4 ................................................................. Charleston, SC EGSA 2016 Spring Conference August 11-13 ......................................................Minneapolis, MN March 20-22, 2016; San Antonio, TX December 7-9 ........................................................ Las Vegas, NV* EGSA’s Annual Spring Conference features educational sessions on *To be held concurrently with POWER-GEN International 2015 a broad range of issues impacting today’s On-Site Power industry. Advanced Schools More information will be available at www.EGSA.org or by calling April 20-23 ...................................................................Austin, TX (561) 750-5575. July 13-16 ....................................................................Atlanta, GA October 19-22 ...................................................Salt Lake City, UT Industry Trade Shows POWER-GEN International 2015 December 8-10, 2015; Las Vegas, NV The world’s largest show for power generation, featuring the EGSA On-Site Power Pavilion. For exhibit information, contact EGSA at (561) 750-5575, ext 206 or e-mail Liz Bustamante at [email protected]. Powerline • July/August 2015 www.EGSA.org 5 2015 EGSA Officers ADVERTISERS InDEx President Ed Murphy, Power Search, Inc. [email protected] President-Elect Aaron Equipment Company . 54 Disclaimer Bob Hafich, Emergency Systems Service Company [email protected] Altronic, LLC (GTI Bi-Fuel) . 4 Powerline Magazine is wholly owned and operated by the Electrical Generating Systems Association (EGSA) and Vice President Anna, Inc. 47 includes advertising, press releases, editorials, and other Charlie Habic, Gillette Generators Inc. materials and information submitted by third parties and [email protected] ASCO Power Technologies . 56 gathered by EGSA, its publisher, and its agents and from Secretary-Treasurer contributors. This information is passed along by EGSA for David Brown, Collicutt Energy Services Inc. ComAp . 54 the interest of its members only. With regard to products, [email protected] services and information mentioned, advertised, or printed, Diesel Gas & Turbine Immediate Past President EGSA, its publisher, and its agents, do not investigate the Vaughn Beasley, Ring Power Corporation Publications . 50 merit, accuracy or value of the material or information, [email protected] and make no representations, warranties or endorsements EGSA . 2 of any kind, and hereby disclaim any responsibility to par- 2015 EGSA DIRECTORS Enercon Engineering, Inc. 41 ties using such products, services or information. Readers’ activities are at their own risk. Katie Evans, Diesel & Gas Turbine Publications, Inc. Ed Murphy ESL . 41 With regard to editorials, letters to the editor, columns Ole E. Haaland, Anna Inc. 2015 EGSA President and any other opinions expressed herein, EGSA, its pub- Bill Kaewert, SENS (Stored Energy Systems LLC) [email protected] Generator Solutions, Inc. 53 lisher and its agents, do not ratify, adopt, endorse or verify Rick Morrison, Nixon Power Services Company Hennig Enclosure Systems . 5 such opinions, and hereby state that any opinions, express Dennis Pearson, Woodward or implied, are solely those of the speaker. No information Walter Petty, Atlantic Power Solutions, Inc. Hilliard Corp . 18 is to be regarded as legal advice and reliance thereon and Lanny Slater, GFS Corporation accuracy of statements is hereby disclaimed. Phoenix Products . 40 David J. Stringer, ComAp With regard to information contained herein gener- Tom Wein, Generac Power Systems Inc. Power & Compression Sales . 20 ally, EGSA, its publisher and its agents, do not guarantee, represent or verify the accuracy of any information. EGSA, EGSA STAFF Power-Tronics, Inc. 52 its publisher and its agents, endeavor to provide accurate information, but cannot guarantee the accuracy and hereby Jalane Kellough, Executive Director Pritchard Brown . 18 disclaim liability for any reliance on the information con- Liz Bustamante, Manager of Membership & Technology Ring Power Corp . 11 & 47 tained herein. Peter A. Catalfu, Manager of Communications EGSA, its publisher and its agents, make no representa- Herb Daugherty, Manager of the Rowley School Robinson Enclosures . 19 tions, warranties or endorsements of any kind of the infor- Kim Giles, Marketing Manager mation, opinions, and advertisements contained herein, do Michael Pope, Director of Education Russelectric, Inc. 9 not assert the accuracy of any statements and all reliance Carla Powers, Manager of Conferences & Meetings Showmen Supplies Inc. 18 thereon is hereby disclaimed. Debby Amaral-Robinson, Accounting Manager Herbert V. Whittall, Technical Advisor Thomson Power Systems . 20 Kelly Wilson, Office Manager United Alloy, Inc. 17 SERVICE InFORMATIOn VDO . 44 For Subscriber orders, change of address, reprints, and back issues (when available), contact: Editor, Powerline magazine 1650 S. Dixie Hwy, Suite 400 • Boca Raton, FL 33432 561/750-5575 • Fax 561/395-8557 [email protected] • www.EGSA.org Powerline is published six times per year on a bi-monthly basis. Articles and information submitted for publication
Recommended publications
  • Reliability Analysis for the Emergency Power System of a Pressurized
    CORE Metadata, citation and similar papers at core.ac.uk Provided by Digital Repository @ Iowa State University Iowa State University Capstones, Theses and Retrospective Theses and Dissertations Dissertations 1984 Reliability analysis for the emergency power system of a pressurized water reactor facility during a loss of offsite power transient See-Meng Wong Iowa State University Follow this and additional works at: https://lib.dr.iastate.edu/rtd Part of the Nuclear Engineering Commons Recommended Citation Wong, See-Meng, "Reliability analysis for the emergency power system of a pressurized water reactor facility during a loss of offsite power transient " (1984). Retrospective Theses and Dissertations. 7741. https://lib.dr.iastate.edu/rtd/7741 This Dissertation is brought to you for free and open access by the Iowa State University Capstones, Theses and Dissertations at Iowa State University Digital Repository. It has been accepted for inclusion in Retrospective Theses and Dissertations by an authorized administrator of Iowa State University Digital Repository. For more information, please contact [email protected]. INFORMATION TO USERS This reproduction was made from a copy of a document sent to us for microfilming. While the most advanced technology has been used to photograph and reproduce this document, the quality of the reproduction is heavily dependent upon the quality of the material submitted. The following explanation of techniques is provided to help clarify markings or notations which may appear on this reproduction. 1.The sign or "target" for pages apparently lacking from the document photographed is "Missing Page(s)". If it was possible to obtain the missing page(s) or section, they are spliced into the film along with adjacent pages.
    [Show full text]
  • City of Plattsburgh (SUNY)
    56 - City of Plattsburgh (SUNY) August 2016 Notice The opinions expressed in this report do not necessarily reflect those of the New York State Energy Research and Development Authority (hereafter “NYSERDA”) or the State of New York, and reference to any specific product, service, process, or method does not constitute an implied or expressed recommendation or endorsement of it. Further, NYSERDA, the State of New York, and the contractor make no warranties or representations, expressed or implied, as to the fitness for particular purpose or merchantability of any product, apparatus, or service, or the usefulness, completeness, or accuracy of any processes, methods, or other information contained, described, disclosed, or referred to in this report. NYSERDA, the State of New York, and the contractor make no representation that the use of any product, apparatus, process, method, or other information will not infringe privately owned rights and will assume no liability for any loss, injury, or damage resulting from, or occurring in connection with, the use of information contained, described, disclosed, or referred to in this report. NYSERDA makes every effort to provide accurate information about copyright owners and related matters in the reports we publish. Contractors are responsible for determining and satisfying copyright or other use restrictions regarding the content of reports that they write, in compliance with NYSERDA’s policies and federal law. If you are the copyright owner and believe a NYSERDA report has not properly attributed your work to you or has used it without permission, please email [email protected] ii PON 3044 Final Report – Plattsburgh Table of Contents Executive Summary ......................................................................................................................................
    [Show full text]
  • D3.1. State of the Art FUSE-IT
    D3.1. State of the Art FUSE-IT Editors: Son Han, Shohreh Ahvar, Noël Crespi, Reza Farahbakhsh, Bahram Alinia (IMT-TSP) Contributors: CCS, CEA-LIST, Evoleo, ICAM, iMINDS, IMT-TSP, ISEP/GCAD, SOGETI, Thales Services, ULR Reviewer: Hélia POUYLLAU (Thales RT) Draft history V.0.1.0 15 Dec 2014 Initial Version (Reviewed by Thales RT) V.1.0.0 30 Jan 2015 Release 1 - Revisions needed: - 3.1.4. Physical Detection and Anti-intrusion Sensors [Thales Services - Introduction] - 3.3.3. Network Operation Centers (NOC) [CCS - Solutions & Products] - 3.4.3. Security Operation Centers (SOC) [CCS – Figure 3.4.4, Situation awareness, limitation of SIEM and/or ad-hoc orchestrator] - 4.1.3. Internet of Things Alliances [SOGETI, technical details] V.1.0.1 30 May 2015 - Revisions needed as in V.1.0.0 - Added Smart Grid and Smart Grid Standards (ISEP/GECAD) - Updated 4.1.3 Internet of Things Alliances (SOGETI) V. Final 22 June 2015 - Updated 3.1.1 Smart Energy sensors, 3.2.2 Building Automation & SCADA (ICAM) - Updated 4.1.3 Internet of Things Alliances (SOGETI) V.Update 8 August 2015 - Added 4.4 Security Standards (IMT) - Updated 4.2.1 Building Automation Standards (IMT) - Added 3.4.1 Smart meters and cyber security (Thales Services) - Added 3.1.3 Heterogeneous traffic data , 3.1.4 Opportunistic spectrum access sensors and 3.4.3 Attacks and threats in IoT (ULR) <FUSE-IT> D3.1. State of the Art Table of Contents 1 Introduction ....................................................................................................................................... 6 1.1 Overview .................................................................................................................................. 6 1.2 FUSE-IT Components ............................................................................................................. 7 2 Related Projects ..............................................................................................................................
    [Show full text]
  • Design of Electrical Power Systems for Nuclear Power Plants
    GUIDE NO. AERB/NPP/SG/D-11 (Rev.1) GOVERNMENT OF INDIA AERB SAFETY GUIDE DESIGN OF ELECTRICAL POWER SYSTEMS FOR NUCLEAR POWER PLANTS ATOMIC ENERGY REGULATORY BOARD AERB SAFETY GUIDE NO. AERB/NPP/SG/D-11 (Rev.1) DESIGN OF ELECTRICAL POWER SYSTEMS FOR NUCLEAR POWER PLANTS Atomic Energy Regulatory Board Mumbai-400094 India July 2020 Price Orders for this guide should be addressed to: Chief Administrative Officer Atomic Energy Regulatory Board Niyamak Bhavan Anushaktinagar Mumbai-400094 India SPECIAL DEFINITIONS (Specific for the Guide) Alternate Power Sources 1 Alternate on-site (e.g. Standby AC power sources / Main generators of other units at multi-unit site) or off-site (e.g. hydro/gas based power station) power sources which can be used to supply power to emergency electric power supply buses. These power supply sources are not part of the electrical power supply system of the NPP. DEC Power Source Power Source reserved for supplying power to the plant when there is total loss of power in all the emergency electric power supply systems during station blackout and also during other design extension conditions (DECs). Electrical Grid The part of electrical power system used for evacuation of power generated in NPP and receiving off-site power. Electrical Protection System A part of electrical system that protects an equipment or system. This encompasses all those electrical, electronic, mechanical, thermal, pneumatic devices and circuitry right from and including sensors, which generate a signal for protection. Electrical Separation Means for preventing one electric circuit from influencing another through electrical phenomena. Emergency Electric Power System (EEPS) That portion of electrical power system provided for supplying electric power to safety-related and safety systems of an NPP during its operational states as well as during accident conditions.
    [Show full text]
  • Automating Emergency Power Supply System Testing in Hospitals | 3 White Paper
    Automating Emergency Power Supply System Testing in Hospitals by Markus F. Hirschbold, Ginni Stieva Executive summary The testing of emergency power supply systems (EPSS) in hospitals plays a critic al role to ensure backup power is available when needed. Due to the shortcomings of manual testing, more hospitals are switching to automated EPSS test systems. This paper demonstrates how automated EPSS tes ting increases reliability due to the accurate monitoring and recording of test parameters, provides tra ceability in case of unanticipated problems with the EPS system or litigation, and helps reduce the staffing burden for such tests. 998 -2 095 - 01 -3 0 - 1 2 AR 0 Contents Executive Summary ............................................................................................ 3 Introduction ........................................................................................................ 4 Why EPSS Testing is Critical ................................................................................ 6 Major Outages Resulting from EPSS Failures ....................................................... 7 Financial Risk of EPSS Failure during a Blackout ................................................. 8 Preventable Adverse (Sentinel) Events ................................................................. 9 Improper Testing Can Cause Reliability to Decrease ...........................................10 Advantages of Automated EPSS Testing ............................................................12 Conclusion ........................................................................................................14
    [Show full text]
  • Emergency Power Systems at Nuclear Power Plants Symposium May 3 – 4, 2017 Munich, Germany
    Emergency Power Systems at Nuclear Power Plants Symposium May 3 – 4, 2017 Munich, Germany TÜV SÜD Industrie Service GmbH TÜV SÜD Akademie GmbH About the Symposium Program Committee After two successful conferences in 2013 and 2015 the third AREVA GmbH (DE), International Symposium Emergency Power Systems at Nuclear Manfred Schwemmlein Power Plants will be organized in May 3 – 4, 2017 in Munich, Caterpillar Motoren GmbH & Co. KG (DE), Germany. Gert Hoffmeister This event addresses the objectives of designers, manufactur- Mitsubishi Heavy Industries, Ltd. (JP) ers, utilities, regulators, vendors and academic organizations. MTU Friedrichshafen GmbH (DE), This international conference for users of emergency power Andreas Görtz systems with its presentations, discussions and its exchange Wärtsilä Finland Oy (FI), of experience emphasizes the importance of reliable power Bjarne Forsbacka, Juha Kerttula, Sari Kojo supplies in case of loss of other power sources in nuclear power plants. Westinghouse Electric Germany GmbH (DE), Tanja Schuler The objective of the Symposium is to support the continuous improvement process for emergency power systems Chairman increase familiarity with international regulation and standards Anton Kollmer, pinpoint and discuss new challenges TÜV SÜD Industrie Service GmbH (DE) The Symposium is intended for specialists at Nuclear power plants and operating companies Power plant design companies Nuclear supervisory and licensing authorities CONFERENCE FEE AND VENUE Engine manufacturers 780,00 € plus current VAT (if applicable) Expert organizations The conference fee covers the symposium materials, Technical an academic institutions beverages during the breaks, lunch and the evening event. The Symposium is also aimed at professionals from industry, TÜV SÜD · Auditorium Chiemsee government agencies and other institutions with similar Westendstraße 199, 80686 Munich, Germany responsibilities.
    [Show full text]
  • Hydrogen Fuel Cell Emergency Power System
    Hydrogen Fuel Cell Emergency Power System Installation and Performance of Plug Power GenCore 5B48 Unit Lech Birek Stanisław Molitorys HYDROGEN FUEL CELL EMERGENCY POWER SYSTEM Installation and Performance of Plug Power GenCore 5B48 Unit Lech Birek Stanisław Molitorys A 30 credit units Master´s thesis Supervisor: Ingolfur Orn Thorbjornsson A Master’s thesis done at RES │ the School for Renewable Energy Science in affiliation with University of Iceland & the University of Akureyri Akureyri, February 2009 Hydrogen Fuel Cell Emergency Power System Installation and Performance of Plug Power GenCore 5B48 Unit A 30 credit units Master’s thesis © Lech Birek, Stanisław Molitorys, 2009 RES │ the School for Renewable Energy Science Solborg at Nordurslod IS600 Akureyri, Iceland telephone: + 354 464 0100 www.res.is Printed in 14/05/2009 at Stell Printing in Akureyri, Iceland ABSTRACT Backup systems are crucial elements of modern electrical grids. They are used in places where an interruption in power supply can cause significant damage, e.g. in hospitals, banks or telecommunication towers. There are many solutions for how emergency power can be delivered. Hydrogen fuel cells are an emerging technology with great potential for the future. Fuel cells combine the advantages of batteries and diesel generators, and eliminate some of their significant disadvantages. They can work as long as they are supplied with fuel via a simple and efficient electrochemical reaction and at the same time they are quiet, produce no emissions and require minimum maintenance. The aim of this thesis is to present the idea of hydrogen fuel cells as reliable backup power systems. The work consisted of two parts: one practical, the other theoretical.
    [Show full text]
  • IAEA Nuclear Energy Series Electric Grid Reliability and Interface With
    IAEA Nuclear Energy Series IAEA Nuclear No. NG-T-3.8No. Plants Power with Nuclear Electric Grid Reliability and Interface IAEA Nuclear Energy Series No. NG-T-3.8 Basic Electric Grid Reliability Principles and Interface with Nuclear Power Plants Objectives Guides Technical Reports INTERNATIONAL ATOMIC ENERGY AGENCY VIENNA ISBN 978–92–0–126110–6 ISSN 1995–7807 IAEA NUCLEAR ENERGY SERIES PUBLICATIONS STRUCTURE OF THE IAEA NUCLEAR ENERGY SERIES Under the terms of Articles III.A and VIII.C of its Statute, the IAEA is authorized to foster the exchange of scientific and technical information on the peaceful uses of atomic energy. The publications in the IAEA Nuclear Energy Series provide information in the areas of nuclear power, nuclear fuel cycle, radioactive waste management and decommissioning, and on general issues that are relevant to all of the above mentioned areas. The structure of the IAEA Nuclear Energy Series comprises three levels: 1 — Basic Principles and Objectives; 2 — Guides; and 3 — Technical Reports. The Nuclear Energy Basic Principles publication describes the rationale and vision for the peaceful uses of nuclear energy. Nuclear Energy Series Objectives publications explain the expectations to be met in various areas at different stages of implementation. Nuclear Energy Series Guides provide high level guidance on how to achieve the objectives related to the various topics and areas involving the peaceful uses of nuclear energy. Nuclear Energy Series Technical Reports provide additional, more detailed, information on activities related to the various areas dealt with in the IAEA Nuclear Energy Series. The IAEA Nuclear Energy Series publications are coded as follows: NG — general; NP — nuclear power; NF — nuclear fuel; NW — radioactive waste management and decommissioning.
    [Show full text]
  • 2011 FUEL CELL TECHNOLOGIES MARKET REPORT July 2012 Authors
    2011 FUEL CELL TECHNOLOGIES MARKET REPORT July 2012 Authors This report was a collaborative effort by staff of the Breakthrough Technologies Institute, Inc., in Washington, DC. Acknowledgement The authors relied upon the hard work and valuable contributions of many men and women in government and in the fuel cell industry. The authors especially wish to thank Sunita Satyapal and the staff of the US Department of Energy’s Fuel Cell Technologies Program for their support and guidance. The authors also wish to thank Rachel Gelman of the National Renewable Energy Laboratory and the many others who made this report possible. ii Contents List of Figures .....................................................................................................................................................v List of Tables ......................................................................................................................................................vi List of Acronyms ..............................................................................................................................................vii Introduction ..........................................................................................................................................................1 Financial Data .....................................................................................................................................................3 Cost Reduction ...........................................................................................................................................3
    [Show full text]
  • Electrical System
    Revision 20—04/07 KPS USAR 8-i Chapter 8: Electrical System Table of Contents Section Title Page 8.1 DESIGN BASIS . 8.1-1 8.1.1 Principal Design Criteria . 8.1-1 8.1.1.1 Performance Standards . 8.1-1 8.1.1.2 Emergency Power . 8.1-2 8.2 ELECTRICAL SYSTEM. 8.2-1 8.2.1 Network Interconnections . 8.2-1 8.2.1.1 Substation DC System . 8.2-3 8.2.2 Plant Distribution System . 8.2-4 8.2.2.1 Single Line Diagrams. 8.2-4 8.2.2.2 Main Auxiliary, Reserve Auxiliary and Tertiary Auxiliary Transformers . 8.2-4 8.2.2.3 4160V System . 8.2-4 8.2.2.4 480V System . 8.2-5 8.2.2.5 125V and 250V DC System. 8.2-6 8.2.2.6 Instrument Bus . 8.2-8 8.2.2.7 Evaluation of Layout and Load Distribution . 8.2-8 8.2.2.8 Separation Criteria . 8.2-9 8.2.2.9 Relay Room . 8.2-13 8.2.2.10 Testing . 8.2-13 8.2.3 Emergency Power . 8.2-14 8.2.3.1 Sources Description . 8.2-14 8.2.3.2 Loading Description. 8.2-17 8.2.3.3 Load Evaluation . 8.2-21 8.2.3.4 Batteries and Battery Chargers . 8.2-24 8.2.3.5 Reliability Assurance . 8.2-25 8.2.3.6 Surveillance Requirements . 8.2-27 8.2.4 Station Blackout . 8.2-27 8.2.4.1 Introduction .
    [Show full text]
  • Power Failures on Ships Safety Study
    Power Failures on Ships Safety study Investigation number: M2016-S1 FOREWORD On the basis of section 2 of the Safety Investigation Act (525/2011), the Safety Investigation Authority decided to initiate a safety study on power failures on ships. Senior researcher Sirpa Kannos led the investigation team until 24 February 2017, after which Lieutenant Senior Grade (retired) Jari Alanen took over as investigation team leader. As members of the joint in- vestigation team were appointed Captain (Master of Maritime Management) Teemu Leppälä, Chief Engineer Tuomo Leppälä and Captain (Master of Maritime Management) Johanna Vahtera. In addition, on site investigations were conducted by Captain Bengt Malmberg, Cap- tain Mikko Rausti and Naval Architect Niklas Rönnberg. Chief Engineer and Electrical Engi- neer Pekka Ilmiö was appointed expert on power failures. Chief Marine Safety Investigator Risto Haimila was Investigation Leader. This safety study report describes the investigation process, gives general information about power failures on ships and presents acts and regulations concerning power failures on ships. The reports on specific cases as well as a joint analysis on them are included. At the end of this report safety recommendations are presented. By implementing them, similar accidents and incidents can be avoided in the future, or their consequences can be mitigated. The purpose of safety investigation is increasing public safety, preventing accidents and inci- dents as well as mitigating damages caused by accidents. Safety investigations do not consider possible liabilities or obligations to compensate for damages. The use of investigation reports for any purpose other than to improve safety must be avoided. Power failures in narrow fairways and in areas with dense traffic can cause very serious sea- and environmental accidents.
    [Show full text]
  • Defence in Depth of Electrical Systems and Grid Interaction
    CSNI Draft Report DEFENCE IN DEPTH OF ELECTRICAL SYSTEMS AND GRID INTERACTION Final DIDELSYS Task Group Report 1 2 Forward The July 2006 Forsmark-1 event identified a number of design deficiencies related to electrical power supply to systems and components important to safety in nuclear power plants. While plant- specific design features at Forsmark-1 contributed to the severity of the sequence of events which occurred at Forsmark, a number of the design issues are of a generic nature as they relate to commonly used approaches, assumptions, and design standards for voltage protection of safety related equipment. The NEA Committee on the Safety of Nuclear Installations (CSNI) authorized formation of a task group in January 2008 to examine Defence in Depth of Electrical Systems and Grid Interaction with nuclear power plants (DIDELSYS). The task was defined based on the findings of an NEA sponsored workshop on lessons learned from the July 2006 Forsmark-1 event held in Stockholm, Sweden in 5-7 September 2007. The task group members participating in this review included: • John H. Bickel, ESRT, LLC (Sweden) - Chairman • Alejandro Huerta, OECD/NEA - Secretary • Per Bystedt, SSM (Sweden) • Tage Eriksson, SSM (Sweden) • Andre Vandewalle, Nuclear Safety Support Services (Belgium) • Franz Altkind, HSK (Switzerland) • Thomas Koshy, USNRC (United States) • David M. Ward, Magnox Electric Co. (United Kingdom) • Brigitte Soubies, IRSN (France) • Kim Walhstrom, STUK, (Finland) • Alexander Duchac, EC Joint Research Center Petten (European Commission)
    [Show full text]