Frankfurt IV CyrusOne Data Center Willhelm Fay Strasse am Main

Latitude: 50 07 57.56 N Longitude: 8 34 43.03 E

CyrusOne Frankfurt IV is a brand-new purpose-built data center offering cloud providers, systems integrators and multinational corporations customised, secure and resilient data center solutions within a key business hub.

The facility is strategically located in Sossenheim, the preferred location for data centers in Frankfurt, Germany’s “Digital City”. It sits just 500 meters from CyrusOne Frankfurt lll delivering 11 MW of IT power Overview to 5,392 sq m (58,039 sq ft) of world-class • 11 MW of IT power delivered to 5,392 sq m (58,039 sq ft) of world-class technical technical space, with each data suite space within a four storey data center customised to individual client specifications. • Active / Active 20 kV dual redundant power supplies with fully flexible IT power solutions • Connection to the European high voltage grid via two independent substations • Low PUE through the use of adiabatic free cooling chillers Frankfurt 5 am Main Ost • Highly resilient, concurrently maintainable power and cooling to Tier III Frankfurt am Main Mitte-Nord • Carrier neutral access and diverse fibre connectivity to active A&B Meet Me Rooms from 66

Bockenheim multiple telecommunication providers Sossenheim 648 Frankfurt • Bespoke and scalable data halls Frankfurt am Main West • Multilayer industry-leading levels of physical and electronic security Sachsenhausen-Nord • Dedicated offices, buildroom and/or ancillary space adjacent to each hall

Schwanheim Frankfurt.. • Dedicated distributed redundant electrical infrastructure to each data hall am Main Sud

5 • Secure managed delivery bay with five tonne goods lift 3 • 24/7 year round onsite support 3 Frankfurt Airport

CyrusOne Enterprise Data Centers | [email protected] | CyrusOne.com LowPUEthroughtheuseoptimumchilledwater temperatures • Adiabaticfreecoolingchillers • Aircooledplantroomswhenconditionspermit • 20%RHto80%RHsupplyaircontrolband • 25+/-2°Csupplyaircontrolband • Variable speeddriveCRAHunitsfans • Variable speeddrivechilledwaterpumps • • EfficiencyEnergy configuredinadistributed redundanttopology Powersuppliestocoolingequipmentforfullredundancy • Independentlyregulatedtemperatureandhumidity • CoolinginfrastructureindividuallymanagedandlinkedtoBMS • temperaturestomaximisethefreecoolinghours LowPUE duetocoolingsolutionandoptimumchilledwater • Circulation pumpsN+1 • Computer roomairhandlingunitsatN+50% • N+1adiabatic freecoolingairchillers • 2.75MW ITcapacitycoolingsolutionperfloor • Cooling configuredonaresilientringchilledwatersystem • Cooling Re-fuelling contractstoensuretimelyreplacement • autonomy, capable ofcontinuousrunning Fullyrated N+1MVback-upgeneratorswith48-hourfuel • back-upasstandardtwoUPSsystemsperblock Distributed redundantUPStopologywithten-minutebattery • allthreeblocks eachblockcreatingameshedITdistributiontopologybetween feedsfrom andreserve ITpower suppliesderivedfromprimary • 99.999% reliabilitywiththeabilityforconcurrentmaintainability • andcompartmentalisedblocks 2.75MW distributedredundanttopologywiththreeindependent • AllITpower meteredandchargedasconsumed • routedactive/withacapacityof20MVA Mainspowersuppliedvia100%rated A&B 20KV incomersdiversely • Power Frankfurt IV Scalable UPScapableofECOandsequencemodes Technical Specifications Fire DetectionandSuppression withoutacloudon-ramp toservices Megaportpointofpresenceavailableonsiteprovidingnetworkaccess • euNetworksandZayo MeetMeRoomsfrommultipletelecommunicationprovidersincluding Carrierneutralaccessanddiversefibreconnectivitytoactive A&B • Connectivity Real-timemonitoringofelectricalandmechanicalsystems • PreventativeMaintenance(PPM)programmes 24/7year-round on-siteM&EengineersundertakingPlanned • Powersurgemanagement • Powerandbuildingmonitoringsystemstoprovidealarms • ManagementSystems(BMS&EMS) Building &Energy FiredetectionandsuppressionsystemsinterconnectedtocentralBMS • andUPSrooms Nitrogenbasedcentralisedgassuppressionsystemtodatahalls • asrequired Firedetectioninallrooms, ceilingreturnairplenumsandinvoids • plantroomsforearlywarning VESDA(Very EarlySmokeDetection Apparatus) indatahallsandUPS • ThreestagefiredetectionsystemsintodatahallsandUPSplantareas • Typical FloorPlan Offices 10 12 13 14 15 16 10 12 13 14 15 11 11 16 15 14 13 12 10 15 14 13 12 10 11 11 1 7 8 9 3 5 6 7 8 9 2 4 9 8 7 6 5 4 3 2 9 8 7 1 19 18 17 19 18 17 16 30 29 28 27 26 25 24 23 22 21 20 31 30 29 28 27 26 25 24 23 22 21 20 17 18 19 20 22 23 24 25 26 27 28 29 30 16 17 18 19 20 22 23 24 25 26 27 28 29 30 21 31 21

Cooling

Fibre Riser NGF: 1,40 m2 Power A Data Hall Data • Dual redundant networks and BMS servers forresilience Dualredundant networksandBMSservers • requirements Phasing toallowforsubtlechangesineachhall/tenantspecification/ • andN+Ngeneratorpanelsforincreasedresilience Integrated A&B MVinfrastructurealongwithN+1generators • Sequence andvariablemodeUPSmodulesdedicatedtoeachhall • Aircooled UPSmodules • State-Of-The-Art Engineering Mantraps withbiometricreadersintodatahallsifrequired • Progressive layersofsecuritytorestrictaccessthroughthesite • Extensive CCTVandaccesscontrolthroughoutthefacility • 24/7year-round on-sitesecuritylocatedinsecurecontrolroom • PAS68 ratedgatestoprotectfromvehicleattack • External CCTV • 3metre high secureperimeterfencetoCPNIbasespecification • Security ISO50001 EnergyManagement • ISO9001 QualityManagement • ISO27001InformationSecurityManagement • ISO14001EnvironmentalManagement • Compliance (OperatedtoInternationalStandards) oe oe Store Power C Power B

Cooling 17 18 19 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 20 21 22 23 24 25 26 27 28 29 30 30 29 28 27 26 25 24 23 22 20 19 18 17 16 30 29 28 27 26 25 24 23 22 20 19 18 17 21 31 21 15 14 13 12 11 10 1 16 15 14 13 12 11 10 9 8 7 6 5 3 9 8 7 10 10 12 13 14 15 4 2 13 14 15 16 2 3 4 5 6 7 8 9 7 8 9 12 11 11 1 [email protected]

IDF / Fibre B Fibre Riser NGF: 0,90 m2 NGF: 11,64 m2 | CyrusOne.com