Humidity Dial Indicators

Total Page:16

File Type:pdf, Size:1020Kb

Humidity Dial Indicators Registration Web Table-of-Contents Humidity HU Dial Indicators Thermohygrometer Thermohygrometer Wall Clock Easy-to-read dial indicators for both Clock displays time, humidity, and temperature temperature and humidity This attractive silver rim and black face multiparameter wall meter Monitor conditions of your lab, displays time, humidity, and office, or food storage area temperature. Easily view with this economical thermo- time, humidity, hygrometer. Displays in °F and °C. or temperature No batteries or external power from separate are required for operation. measurement dials. Temperature is displayed in °F and °C. What’s included: one AA battery. 35700-10 37803-25 Specifications & Ordering Information Specifications & Ordering Information Response time: 1 minute Dimensions: 5" dia x 11/8"D Response time: 1 minute Power: one AA battery (included) Display: analog Display: analog Dimensions: 93/4" dia x 11/2"D Mode RH Temperature Mode RH Temperature Range 25 to 80% –4 to 104°F (–20 to 40°C) Range 0 to 100% –40 to 120°F (–40 to 50°C) Resolution 1% 2°F/1°C Resolution 0.1% 2°F/1°C ±5% from 25 to 70% Accuracy ±3.6°F/±2°C ±8% from 71 to 80% Accuracy ±3% of reading ±4°F (±2°C) Catalog number Description Price Catalog number Description Price KH-35700-10 Thermohygrometer KH-37803-25 Thermohygrometer wall clock Accessories KH-09376-01 Replacement batteries, 1.5 V, AA. Thermohygrometer Pack of 4 EK-17030-20 Calibration service; NIST-traceable certificate, three with Large Dial humidity and one temperature test points Large 10" dial display allows you to view temperature from a distance Thermohygrometer View temperature conditions from a distance with the with Glass Thermometer big 10" diameter thermohygrometer. Features alcohol-filled This indicator features thermometer a dual temperature display in °F and °C. Use this indicator for RH No batteries or and temperature readings power required. in your lab, office, or computer room. Instrument requires no batteries or power. This indicator features a °F/°C thermometer. 35700-20 03313-70 Specifications & Ordering Information Specifications & Ordering Information 1 11 Response time: 1 minute Dimensions: 103/4" dia x 13/8"D Response time: 1 minute Dimensions: 4 /8" dia x /16"D Display: analog Display: analog Mode RH Temperature Mode RH Temperature Range 25 to 80% –22 to 122°F (–30 to 50°C) Range 20 to 99% –4 to 120°F (–20 to 50°C) Resolution 5% 2°F/1°C Resolution 1% 10°F (5°C) ±5% from 25 to 70% ±4% from 68 to 122°F (20 to 50°C), Accuracy ±3.6°F/±2°C Accuracy ±10°F (±5°C) ±8% from 71 to 80% ±5% outside this range Catalog number Description Price Catalog number Description Price KH-35700-20 Thermohygrometer with large dial KH-03313-70 Thermohygrometer with glass thermometer l U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com 739 Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300 Registration Web Table-of-Contents HU Humidity Dial Indicators Brass Case Thermohygrometer with Thermohygrometers Digital Thermometer Provide fast, accurate measurements Switch-selectable °F or °C scale in a visually appealing brass case Easily mount this thermohygrometer Choose an indicator for % RH in your office, laboratory, measurement only; % RH and °F greenhouse, or food storage measurements; or % RH, °F, and °C environments. This measurements. All models have a thermohygrometer remains durotherm RH sensor that measures accurate and stable without relative humidity from 0 to 100% RH. maintenance or adjustments. Thermohygrometers feature a 03310-00 Case is constructed of bimetallic temperature sensor. corrosion-resistant ABS plastic. Models 03310-20 and 03310-40 What’s included: one AA battery, include a test certificate mounting bracket, and screws. ensuring conformance to 35700-00 stated specifications. All indicators have a solid brass Specifications & Ordering Information case, a 5" diameter glass face, 03310-40 and predrilled holes for wall mounting. Response time: 1 minute Power: one AA battery (included) Display Dimensions: 5" dia x 11/8"D Specifications & Ordering Information RH: analog 1 Response time: 1 minute Dimensions: 6" dia x 11/2"D Temperature: 3 /2-digit LCD, 0.50"H Display: analog Mode RH Temperature Catalog number KH-03310-20 KH-03310-00 KH-03310-40 Mode %RH %RH, °F %RH, °F/°C Range 20 to 100% 0 to 160°F (–18 to 72°C) Range 0 to 100% Resolution 2% 0.1°F (0.1°C) RH Resolution 1% 2% 2% RH Accuracy ±4%, 20 to 90%; ±8%, 90 to 100% ±1.8°F (±1.0°C) Accuracy ±3% (35 to 95%), ±5% (<35%, >95%) Range — 10 to 170°F 10 to 170°F (–12 to 76°C) Catalog number Description Price Temp Resolution — 5°F 5°F (2°C) KH-35700-00 Thermohygrometer with digital thermometer Accuracy — ±1% full-scale ±1% full-scale Price EK-17030-20 Calibration service; NIST-traceable certificate, three humidity and one temperature test points KH-09376-01 Replacement batteries, AA. Temperature/Humidity/Process Dataloggers Humidity Card l Compact, rugged housing guarantees operation in busy or rugged areas! Card indicates both the current humidity and Automatically log up to the maximum humidity attained! 16,000 temperature (°F or l °C) and humidity (%RH) Non-reversible maximum humidity indicator is perfect measurement readings for for packaging and shipping months, then download l NIST-Traceable data to your computer or Easy-to-read card is ideal for use printer. Sample from once with bottles, chemicals, plastic per 10 seconds to once per bags, electronics, desiccators, 2 hours—built-in clock and and storage containers. calendar track your data Maximum range (highest in real time. Dataloggers humidity attained when exposed require software for 24 hours or more) is 50 to 35710-50. Kits include 90% RH—orange dot indicator datalogger, software, 35710-00 changes to yellow in increments and cable. of 10% RH. Maximum memory Model Model range is readable to an accuracy Specifications & Ordering Information 35710-00 35710-10 of ±5% RH at 75°F (24°C). Power: 3.6 V lithium battery (included) Reversible current humidity (0 to 100% RH) changes color 03313-06 Dimensions: 1"D x 23/4" dia from blue to bright pink in Parameters No. of channels Range Display increments of 10% RH; accuracy of ±2.5% RH at 75°F (24°C). Card Temperature One internal, –22 to 122°F (–30 to 50°C) 2-digit LCD; arrives ready for use—each card is individually sealed in a clear Humidity one external 0 to 100% RH 3⁄8"H moisture-barrier bag with desiccant to keep the card dry and Dataloggers Datalogger kits provide for an extended shelf life. Description Cat. no. Price Cat. no Price What’s included: NIST-traceable certificate. Temperature EK-35710-00 EK-35710-60 Temperature/RH EK-35710-10 EK-35710-62 EK-35710-50 Microlab software and 8-ft cable. Set sampling rate; Specifications & Ordering Information view data graphically; store/export data in spreadsheet format Catalog number Description Size Qty/pk Price/pk ® (CD-ROM). Windows 95/98/2000/NT compatible KH-03313-06 NIST-traceable humidity card 4"W x 4"H 6 740 l U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300 Registration Web Table-of-Contents Humidity HU Psychrometers Pocket Sling Psychrometers Take this pocket-sized unit with you anywhere! 03322-00 A low-cost To operate psychrometer, withdraw thermometer halfway out of case, then moisten wick. Holding the case as a handle, swing instrument for the psychrometer for two minutes. Read wet and dry bulb wet bulb, dry bulb, temperatures, then reinsert thermometer slide into case. The and RH slide and case form a slide rule for calculating RH. Choose °F or °C models. The °F models are available with either mercury- or spirit-filled thermometers—use spirit-filled model in mercury-free environments. Specifications & Ordering Information Catalog number KH-03322-00 KH-03322-10 KH-03322-20 Description °F mercury filled °C mercury filled °F spirit filled Accessories Range 10 to 100% RH Resolution 2% KH-03322-50 Replacement glass thermometers, Accuracy ±3% 20 to 120°F, mercury-filled. Pack of two Range 20 to 120°F –5 to 50°C 20 to 120°F KH-03322-60 Replacement glass thermometers, Temp Resolution 1°F 0.5°C 1°F –5 to 50°C, mercury-filled. Pack of two Accuracy ±1°F ±0.5°C ±1°F Dimensions 13⁄8"W x 81⁄4"H x 5⁄8"D (when closed) KH-03322-70 Replacement glass thermometers, Price 20 to 120°F, spirit-filled. Pack of two KH-03322-82 Replacement wicks, 200-mm. Pack of six Sling Psychrometer Classic twirling design This psychrometer is fast, accurate, and easy to use. Features an environmentally friendly red spirit mercury-free thermometer, ABS construction, and an extra large handle. To operate, simply moisten the wick, twirl the psychrometer for two minutes, and then read the wet and dry bulb temperatures. Use the instructions and conversion chart supplied in order to calculate the relative humidity. (Available in °C only.) 03322-90 What’s included: two thermometers, one wick, conversion chart, and carrying case. Specifications & Ordering Information Response time: 2 minutes Power: hand operated Display: thermometers Dimensions: 13⁄4"W x 81⁄2"H x 1"D Catalog number KH-03322-90 Accessories Range 10 to 100% RH Resolution 2% KH-03322-91 Replacement kit contains one wick and two glass red Accuracy ±3% spirit thermometers Range 0 to 50°C EK-17005-00 Calibration service; NIST-traceable Temperature Resolution 0.1°C Accuracy ±0.3°C Price Humidity Calculator and Mason Hygrometer Calculate relative humidity with wet and dry bulb temperatures Humidity calculator (03311-00) matches wet and dry bulb temperatures on a slide scale for humidity values.
Recommended publications
  • Mold, Moisture, and Houses – Ventilation Is an Effective Weapon 1 June 2009
    Mold, Moisture, and Houses – Ventilation is an Effective Weapon 1 June 2009 MOLD, MOISTURE, AND HOUSES – VENTILATION IS AN EFFECTIVE WEAPON This guideline document provides an overview of residential mold prevention in plain language that may be understood by the average consumer – the resident of today’s North American housing. It provides a basic scientific explanation of mold fundamentals, findings related to problems blamed on mold, and an introduction to psychrometrics - the science of air containing moisture. That scientific base is then applied as a general guideline for making the practical decisions associated with residential design, construction, ventilation and operation for effective mold control. Written by: David W. Wolbrink With inputs from: Rick Olmstead, Paul H. Raymer, Donald T. Stevens, John Ehlen, James D. Boldt, Daniel T. Forest, Gord Arnott, Joel Borque Home Ventilating Institute 1000 North Rand Road, Suite 214 Wauconda, IL 60084 USA Phone: 847.526.2010 Fax: 847.526.2993 e-mail: [email protected] Website: www.hvi.org Copyright © 2009 Home Ventilating Institute TABLE OF CONTENTS 1. Executive Summary........................................................................................ 2 2. Introduction to This Guideline......................................................................... 3 3. Mold: Friend and Enemy................................................................................. 4 4. Moisture and Air Around Us............................................................................ 7 5. The House:
    [Show full text]
  • Museum Collections Environment
    Chapter 4: Museum Collections Environment A. Overview.................................................................................................................................. 4:1 What information will I find in this chapter? .................................................................................. 4:1 Who should read this chapter? ................................................................................................... 4:1 What are the agents of deterioration that affect the museum environment? ................................... 4:1 B. Developing the Critical Eye...................................................................................................... 4:3 What is the "critical eye?" ........................................................................................................... 4:3 What kinds of materials will I find in a museum collection?............................................................ 4:4 What is deterioration? ................................................................................................................ 4:5 What is chemical deterioration? .................................................................................................. 4:6 What is physical deterioration? ................................................................................................... 4:6 What is inherent vice? ................................................................................................................ 4:7 Why is it important to understand the environmental
    [Show full text]
  • Methods of Measuring Humidity and Testing Hygrometers
    NBS CIRCULAR Methods of Measuring Humidity and Testing Hygrometers UNITED STATES DEPARTMENT DF COMMERCE NATIONAL BUREAU OF STANDAROS PERIODICALS OF THE NATIONAL BUREAU OF STANDARDS As the principal agency of the Federal Government for fundamental research in physics, chemistry, mathematics, and engineering, the National Bureau of Standards conducts projects in fourteen fields: electricity, optics, metrology, heat and power, atomic and radiation physics, chemistry, mechanics, organic and fibrous materials, metallurgy, mineral products, building technology, applied mathematics, electronics, and radio propagation. The Bureau has custody of the national standards of measurement, and conducts research leading to the improvement of scientific and engineering standards and of tech- niques and methods of measurement. Testing methods and instruments are developed; physical constants and properties of materials are determined; and technical processes are investigated. Journal of Research Internationally known as a leading scientific periodical, the Journal presents research papers by author- ities in the specialized fields of physics, mathematics, chemistry, and engineering. Complete details of the work are presented, including laboratory data, experimental procedures, and theoretical and mathe- matical analyses. Each of the monthly issues averages 85 two-column pages; illustrated. Annual subscription: domestic, $5.50; foreign, $6.75. Technical News Bulletin Summaries of current research at the National Bureau of Standards are published each month in the Technical News Bulletin. The articles are brief, with emphasis on the results of research, chosen on the basis of their scientific or technologic importance. Lists of all Bureau publications during the preceding month are given, including Research Papers, Handbooks, Applied Mathematics Series, Building Materials and Structures Reports, Miscellaneous Publications, and Circulars.
    [Show full text]
  • Humidity Vaisala Humicap® Sensor for Measuring Relative Humidity
    Humidity / TECHNOLOGY DESCRIPTION Vaisala HUMICAP® Sensor for Measuring Relative Humidity ® In 1973, Vaisala introduced HUMICAP , the world’s first thin- HUMICAP in Brief film capacitive humidity sensor. Since then, Vaisala has Box headline here ▪ A capacitive thin-film polymer become the market leader in relative humidity measurements, sensor and thin-film capacitive humidity sensors have developed from ▪ Full measurement range one company’s innovation into a global industry standard. 0...100 %RH ▪ Accurate to ±1 %RH Vaisala HUMICAP sensors guarantee the dielectric properties of the ▪ Traceable humidity quality and reliability, with their polymer film change, and so does measurement reputation for accuracy, excellent the capacitance of the sensor. The ▪ Nearly 40 years on the market long-term stability, and negligible instrument’s electronics measure hysteresis. the capacitance of the sensor and convert it into a humidity reading. HUMICAP’s Unique Benefits How It Works ▪ Excellent long-term stability HUMICAP is a capacitive thin-film Typical Applications for Insensitive to dust and most polymer sensor consisting of a Humidity Measurement ▪ chemicals substrate on which a thin film of Vaisala’s humidity instruments with polymer is deposited between two HUMICAP sensors are suitable for ▪ Chemical purge option for stable measurements conductive electrodes. The sensing a wide range of applications. From in environments with high surface is coated with a porous power and steel to life sciences and concentrations of chemicals metal electrode to protect it from building automation, many industries contamination and exposure to need to measure humidity – here are ▪ Sensor heating for measurements even in condensation. The substrate is just a few: condensing environments typically glass or ceramic.
    [Show full text]
  • The Dehumidification Handbook, Third Edition
    The Dehumidification Handbook Third Edition ISBN 0-9717887-0-7 Copyright 1989, 2002 and 2019 © Munters Corporation The Dehumidification Handbook Third Edition Copyright 1989, 2002 and 2019 © Munters Corporation Reuse Of This Material For book reviews and personal educational and professional use, readers are encouraged to excerpt or photocopy and distribute any useful portion of this handbook, provided that the source of the material is appropriately referenced and the Munters copyright is acknowledged. For electronic distribution or if the material will be included in any printed publication, Munters Corporation must provide written authorization in advance of publication. For those uses, please contact Munters Corporation Marketing Department by mail at 79 Monroe Street, Amesbury, MA 01913, or by email at [email protected]. Disclaimer Although great care has been taken in the compilation and publication of this book, no warranties either expressed or implied are given in connection with the material. Neither the contributors nor the publisher take any responsibility whatsoever for any claims arising from its use. The entire risk of the use of this information is assumed by the user. However, to improve future editions, the publisher welcomes any and all comments, corrections or suggestions from readers. CONTRIBUTORS We would like to express our gratitude to Lew G. Harriman III as editor of the first two editions of this book and for guiding this work with interest. Also, we would like to thank the following original contributors and 1989 Editorial Advisory Board members for their work; Enno Abel, Nick Baranov, Bruce Bonner, Steven Brickley, Luiz Felipe de Carvalho, Douglas Kosar, Hansi Kruger, Ralph Lahmon, Milton Meckler, Mohamed Moledina, Terry Penny, Ing.
    [Show full text]
  • Handheld Temperature/ Humidity Indicator Model RH31
    Handheld Temperature/ Humidity Indicator Model RH31 Features U Simultaneous U Data Hold Function The RH31 digital Digital Display of Both Provided thermo-hygrometer is compact Temperature and U C/ F Switchable and easy to use and has Humidity U features of simultaneous Power Auto-Off Function display of temperature and U Display of Relative Provided humidity, selectable display Humidity, Dew-Point U Model with Memory of relative humidity, dew-point Temperature and Function are Available temperature, wet-bulb Wet-Bulb Temperature (RH31-RS232) temperature, and data hold. is Selectable (Temperature, Humidity, The RH31-RS232 has an U Interchangeable Measuring Time) RS-232C serial communications Sensors with Connectors interface for datalogging to a x 1500 Data Points. computer. Specialized humidity sensors– general type, thin type and separated type – are interchangeable. Units RH31 Series are °C/ °F switchable by internal jumper. $ RH31-RS232 420 shown with Basic Model optional sensors RH31 Hu-11 Model RH31 Display Part RH31-RS232 Indication of temperature, Specifications humidity, unit and battery shortage mark and Features Power switch Specifications Hold key RH31 Meter Measuring range: Read key Transmission Temperature: –10 to 60°C of data storage Relative humidity: 0 to 100% RH to personal computers Accuracy rating: Clear key Temperature: Write key ±(0.1% of measured value +0.2°C) Setting of Relative humidity: current time and data General type sensor ±(0.1% of measured value +0.2% RH) storage Dew-point temperature: ±1.0°C starting Wet-bulb
    [Show full text]
  • Abbeon Cal Inc. Ph: 800.922.0977 Fax: 805.676.0721 [email protected] 3 Abbeon Cal, Inc
    XP200 KIT OPUS20 HTAB176 XC250 Abbeon Cal Inc. Ph: 800.922.0977 Fax: 805.676.0721 [email protected] www.AbbeonInstruments.com 3 Abbeon Cal, Inc. Lufft Supplier 1363 Donlon St. Unit 1, Ventura, CA 93003 Abbeon’s Certified Humidity/Temperature Instruments HTAB-176 Humidity and Temperature The Abbeon Certified Hygrometer Model HTAB-176 is certified to be accurate within ± 3% RH + 1 scale division. The dial indicates the complete range of 0 to 100% relative humidity. Each instrument has been tested at three different positions of the dial at temperatures ranging from 32° to 230°F. The calibration and certification are done under ISO-9001 control. The bi-metallic thermometer on the model HTAB-176 is accurate to ±1% (0 - 40°C) of scale with a range of -20 to 100° Centigrade and 0 to 210° Fahrenheit. Graduations are ±1° + 1 scale graduation for Centigrade, 2° Fahrenheit and 1% RH. This is the only humidity indicator that we know of that has a 1-year guarantee and a 5-year warranty. Some of our humidity indicators working on the same principle as this instrument have been in use for over 20 years and are giving satisfactory service day after day, month after month, and year after year. Both the humidity HTAB-176 and temperature are direct read without any calculations whatsoever. Solid 6-inch overall brass case drilled for wall mounting. Shipping weight: 3 pounds. Color differentiated 5-inch dial with black letters and numbers and red pointer. HTAB-176 Hygrometer/Thermometer Test certificate included NIST NIST Certification TAB-77 Temperature The TAB-77 has an easy-to-read 5-inch dial that indicates the temperature in a range of -20 to 120° Fahrenheit or -30 to 50° Celsius.
    [Show full text]
  • Humidity, Pressure and Carbon Dioxide Measurement for Low Dewpoint OEM Measurements Using the HMP228 Transmitter for Measuring I
    40234Ymi_Vaisala154 8.9.2000 20:22 Sivu 1 154/2000154/2000 Humidity, pressure and carbon dioxide measurement The New Vaisala DMT242 Dewpoint Transmitter For Low Dewpoint OEM Measurements Vaisala’s ppm Calculation of Moisture in Transformer Oil Using the HMP228 Transmitter PTB210 Series Digital Barometers For Measuring in Extreme Environments Outdoor Plant Growth Experiments In the Elevated CO2 Atmospheres in Japan 40234Ymi_Vaisala154 8.9.2000 20:23 Sivu 2 Contents Presidents’ Column 3 Dewpoint Vaisala has been awarded a contract by the Meteorological Low Dewpoint OEM Measurements 4 Service of Canada (MSC). Humidity Expressed as Dewpoint Temperature 6 Vaisala supplies electronic station barometers to replace U.S. National Weather Service Awards the mercury barometers Dewpoint Contract to Vaisala 8 currently used for weather observation throughout Humidity Canada. The PTB220 digital barometer is easy to maintain, Industrial Humidity Measurements 8 and can be exposed to Reliable Performance in Humid Air extremes of temperature Conditioning Applications 10 between -20 and +60 °C. Improved Maintenance for Transformers 11 Using Automated Long-Term Monitoring of Relative Humidity 13 Carbon dioxide is used to Vaisala Sensor in Radio Telemetry carbonate the beverages in the Instrumentation Systems 16 production of soft drinks. In the United States, OSHA Pressure requires that the carbon Reliable Barometric Pressure Measurement dioxide level remains at, or in All Wind Conditions 18 below, 5,000 ppm in the atmosphere of any filler room PMI20 Digital Barometer Display area. Big Springs Inc. is a - Perfect Partner for Vaisala’s Barometers 20 major soft drink manufacturer Measuring for Extreme Environments and a large local Coca-Cola franchise distributor located in Using PTB210 Barometers 21 Huntsville, Alabama.
    [Show full text]
  • Thermodynamics Lab
    Universität Duisburg-Essen 4. Semester Fak. 5 , IVG Fachgebiet Thermodynamik Laborleiter: Dr. Siddiqi Thermodynamics Lab Humidity Measurement 1 Humidity Measurement Introduction Air comprises a mixture of gases of which nitrogen makes up more than 78%, oxygen 21% and carbon dioxide and the inert gases (argon, neon, krypton, helium etc.) the remainder. These are known as the dry gases of the atmosphere. In addition to these dry gases, the air also contains varying amounts of water vapor. At normal temperatures and pressures water is able to exist in both a liquid and a gaseous (or vapor) form, but it cannot be treated in the same way as the other gases of the atmosphere because its quantity, and hence proportion are continually varying. Water vapor is said to be associated with dry air and the more vapor associated with the dry gases, the more humid the air. Humidity measurements are important not only in meteorology but also in pulp and paper industry, drug and food storage and delivery, film industry etc. Hygroscopic materials draw water from their surroundings and can form solution (e.g., salt, sugar). Strongly hygroscopic materials are used directly for the drying of substances (e.g., gases). The humidity can have dramatic effect on our perception of comfort. It can affect the well-being of a person or even cause diseases. A measure of the water vapor content in the air is the absolute humidity (Feuchte). It shows how many kg of water vapor are present in unit volume (1 m3) of the gas mixture. Depending on the state of the gas mixture (dry or wet) taken as reference one defines: a) Related to the unit volume of the wet gas mixture m kg O = f ′ = W H 2 ′ 3 V m wet air (1a) mw = Mass of water vapor V ′ = Volume of wet gas mixture (slash means here that it is the wet gas mixture) ′ f is also called the density of the water vapor.
    [Show full text]
  • Humidity / Temperature / Dew Point / Carbon
    HUMIDITY / TEMPERATURE / DEW POINT / CARBON DIOXIDE / MOISTURE IN OIL / DISSOLVED GAS ANALYSIS IN TRANSFORMER OIL / PRESSURE / WEATHER / SERVICE OFFERING Humidity and Temperature / TECHNOLOGY DESCRIPTION Vaisala HUMICAP® Sensor for Measuring Relative Humidity ® In 1973, Vaisala introduced HUMICAP , the world’s first thin- HUMICAP in Brief film capacitive humidity sensor. Since then, Vaisala has Box headline here ▪ A capacitive thin-film polymer become the market leader in relative humidity measurements, sensor and thin-film capacitive humidity sensors have developed from ▪ Full measurement range one company’s innovation into a global industry standard. 0...100 %RH ▪ Accurate to ±1 %RH Vaisala HUMICAP sensors guarantee the dielectric properties of the ▪ Traceable humidity quality and reliability, with their polymer film change, and so does measurement reputation for accuracy, excellent the capacitance of the sensor. The ▪ Nearly 40 years on the market long-term stability, and negligible instrument’s electronics measure hysteresis. the capacitance of the sensor and convert it into a humidity reading. HUMICAP’s Unique Benefits How It Works ▪ Excellent long-term stability HUMICAP is a capacitive thin-film Typical Applications for Insensitive to dust and most polymer sensor consisting of a Humidity Measurement ▪ chemicals substrate on which a thin film of Vaisala’s humidity instruments with polymer is deposited between two HUMICAP sensors are suitable for ▪ Chemical purge option for stable measurements conductive electrodes. The sensing a wide range of applications. From in environments with high surface is coated with a porous power and steel to life sciences and concentrations of chemicals metal electrode to protect it from building automation, many industries contamination and exposure to need to measure humidity – here are ▪ Sensor heating for measurements even in condensation.
    [Show full text]