Abbeon Cal Inc. Ph: 800.922.0977 Fax: 805.676.0721 [email protected] 3 Abbeon Cal, Inc

Total Page:16

File Type:pdf, Size:1020Kb

Abbeon Cal Inc. Ph: 800.922.0977 Fax: 805.676.0721 Sales@Abbeon.Com 3 Abbeon Cal, Inc XP200 KIT OPUS20 HTAB176 XC250 Abbeon Cal Inc. Ph: 800.922.0977 Fax: 805.676.0721 [email protected] www.AbbeonInstruments.com 3 Abbeon Cal, Inc. Lufft Supplier 1363 Donlon St. Unit 1, Ventura, CA 93003 Abbeon’s Certified Humidity/Temperature Instruments HTAB-176 Humidity and Temperature The Abbeon Certified Hygrometer Model HTAB-176 is certified to be accurate within ± 3% RH + 1 scale division. The dial indicates the complete range of 0 to 100% relative humidity. Each instrument has been tested at three different positions of the dial at temperatures ranging from 32° to 230°F. The calibration and certification are done under ISO-9001 control. The bi-metallic thermometer on the model HTAB-176 is accurate to ±1% (0 - 40°C) of scale with a range of -20 to 100° Centigrade and 0 to 210° Fahrenheit. Graduations are ±1° + 1 scale graduation for Centigrade, 2° Fahrenheit and 1% RH. This is the only humidity indicator that we know of that has a 1-year guarantee and a 5-year warranty. Some of our humidity indicators working on the same principle as this instrument have been in use for over 20 years and are giving satisfactory service day after day, month after month, and year after year. Both the humidity HTAB-176 and temperature are direct read without any calculations whatsoever. Solid 6-inch overall brass case drilled for wall mounting. Shipping weight: 3 pounds. Color differentiated 5-inch dial with black letters and numbers and red pointer. HTAB-176 Hygrometer/Thermometer Test certificate included NIST NIST Certification TAB-77 Temperature The TAB-77 has an easy-to-read 5-inch dial that indicates the temperature in a range of -20 to 120° Fahrenheit or -30 to 50° Celsius. The pointer actuated by a bi-metallic strip, reads with an accuracy of ±1%C (0 - 40°C) + 1 scale graduation. Comes with a one-year guarantee and five-year warranty. Color differentiated 5-inch dial, 6-inch overall solid brass case, shipping weight: 3 pounds. TAB-77 TAB-77 Thermometer NIST NIST Certification The Hygrometers of Models HTAB-169 and AB-167 are certified to be accurate within ±3% RH + 1 scale division. The dial indicates the complete range of 0 to 100% relative humidity. Each instrument has been tested at three different positions of the dial at temperatures ranging from 32° to 230°F. The calibration and certification are done under ISO-9001 control. Plastic lens available upon request. HTAB-169 Humidity and Temperature Case: Solid gleaming brass, drilled for wall mounting Dial Black with white numbers and letters Dimensions 6" overall, 5" dial HTAB-169 Range 0 to 100% RH -10 to 190°F Accuracy ±3% RH + 1 scale division ±2°F Divisions 1% RH / 2°F gradations Certification Manufactured and tested under ISO-9001 Test certification included Model No. HTAB-169 Hygrometer/Thermometer NIST NIST Certification AB-167 Humidity Case Solid gleaming brass, drilled for wall mounting Dial Black with white numbers and letters Dimensions 6" overall, 5" dial Range 0 to 100% RH Accuracy ±3% RH + 1 scale division Divisions 1% RH gradations Certification Manufactured and tested under ISO-9001. Test Cert included. Model No. AB-167 AB-167 Hygrometer NIST NIST Certification 2 Abbeon Cal, Inc. Lufft Supplier 1363 Donlon St. Unit 1, Ventura, CA 93003 AbbeonInstruments.com Ph 805-676-0720 Fax 805-676-0721 Humidity/Temperature Analog Dial Instruments 5091-00 Humidity and Temperature Case/Cover Chromed brass housing, Mineral glass cover Dimensions 6" overall Range 30 to 100% RH Accuracy ±3% RH + 1 scale division Divisions 1% RH gradations Model No. 5091-00 Hygrometer NIST NIST Certification 5091-00 5064.34 Humidity and Temperature Case: Black aluminum with flange for mounting and chrome bezel Size: 6" overall, 5" dial Range: 0 to 100% RH 10 to 170°F -12 to 75°C Divisions: 3% RH + 1 scale division / 5°F / 2°C Test certification included Model No. 5064.34 Hygrometer/ Thermometer NIST NIST Certification 5064.34 5063.33 Humidity and Temperature Case: Stainless steel with chrome bezel (keyhole in back for hanging). Size: 5¼" overall, 5" dial Range: 0 to 100% RH 10 to 170°F -12 to 75°C Divisions: 3% RH + 1 scale division / 5°F / 2°C Test certification included Model No. 5063.33 Hygrometer/Thermometer NIST NIST Certification 5063.33 5033.32 Humidity and Temperature Case Gleaming brass with flange for mounting Size 6" overall, 5" dial Ranges 0 to 100% RH 10 to 170° F -12 to 75° C Resolution 3% RH + 1 scale division. Temp: ±1°C (0-40°C) + 1 scale graduation. 5°F / 2°C Test certificate included Model No. 5033.32 Thermometer/Hygrometer NIST NIST Certification 5033.32 AbbeonInstruments.com Ph 805-676-0720 Fax 805-676-0721 Abbeon Cal, Inc. Lufft Supplier 1363 Donlon St. Unit 1, Ventura, CA 93003 3 Humidity/ Temperature Analog Dial Instruments 11101 Hygrometer (Humidity - Hair) Outdoor Measurements and High Humidity Hair hygrometers are specially used for outdoor measurements (in shaded or protected areas) or in places where it is very humid. The specially treated human hair of the Hair-hygrometer 11101 is temperature-insensitive (temperature range -35 °C to +65 °C) and reacts quickly to any change of humidity. In low humidity environments, real hair hygrometers will require some maintenance. • Range: 0 to 100 % relative humidity • Accuracy: ± 3 % RH +1 scale div (30 .. 95%) • Graduation: RH 1 % In temperatures up to +80°C (176°F) only high relative humidity will be indicated. In medium to high relative humidity the accuracy of our hygrometers is ±3%. In low humidity it is ±5% after regeneration. 11101 Stainless steel case diameter: 4" (102 mm) Unit weight: 12oz (340g) 12201 Hygrometer (Humidity - Synthetic Fiber) Indoor Measurements and Low Humidity For indoor measurements and in low humidity synthetic hygrometers are preferable. The specially treated fibers of the synthetic hygrometer 12201 are insensitive to temperature (temperature range 0 to +70 °C) and respond quickly to changes in humidity. • Range: 0 to 100 % relative humidity • Accuracy: ± 3 % RH +1 scale div (30 .. 95%) • Graduation: RH 1 % 12201 Stainless steel case diameter: 4" (102 mm) Unit weight: 12oz (340g) Visit AbbeonInstruments.com for more information on both our long standing mechanical meters as well as the digital hand-held meters, dataloggers and compact weather stations. 4 Abbeon Cal, Inc. Lufft Supplier 1363 Donlon St. Unit 1, Ventura, CA 93003 AbbeonInstruments.com Ph 805-676-0720 Fax 805-676-0721 XC200 Meter (Air Temp/Humidity/Dew Point) The powerful and compact handheld device with state-of-the-art and robust design. Excellent accuracy. The high-resolution color screen displays rel. humidity, temperature and dew point. Excellent readability. The calibration function (offset correction) guarantees the long-term use without compromising the accuracy. Hand-held Measuring Device XC200 - Model No. 5700.00 Excellent accuracy of temperature and relative humidity. Display of calculations and statistical functions. Adjustment of local pressure and local height possible. Calibration function and offset correction. Including a calibration certificate. USB interface with SmartGraph3 software. 11 23 3 Technical data Dimensions 6 /16" x 2 /64" x 1 /8" (170 x 60 x 35 mm). Weight: 8.89 oz (250g) Temperature Sensor Principle NTC. Resolution: 0.1 °C Measurement range -4 ° - 122 °F (- 20 … +50 °C) Accuracy ±0.2 °C (0…40 °C) otherwise ±0.4°C Humidity Sensor Principle Capacitive. Measurement range: 0 - 100%RH Accuracy 2%RH. Resolution: 0.1%RH 3 Calculations Dew point temperature °C or °F. Absolute humidity g/m Mixed ratio g/kg or gr/lb Statistical calculations MAX, MIN, HOLD, AVG, ACT, Functions Temperature correction and humidity correction factors (offset) Power saving functions Storage conditions Permitted ambient temp. -4 ° - 140°F (- 20 … +60° C) Permitted rel. humidity <90%r.h. non-condensing Operating conditions Permitted rel. humidity <90%r.h. (20g/m3) non-condensing Permitted altitude 4,000m (above sea level) Power consumption 5.5V ± 10% DC, max. 200mA Power supply Active power consumption Approx. 70mA. Passive Approx. 40μA Battery life Approx. 24h (2.6Ah battery capacity) Warranty 12 months XC250 Meter (Air Temp/Humidity/Dew Point/Surface Temp) The powerful and compact handheld device with state-of-the-art and robust design. Excellent accuracy. The high-resolution color screen displays rel. humidity, temperature and dew point. Excellent readability. The calibration function (offset correction) guarantees the long-term use without compromising the accuracy. Special features: Contact-free temperature measurement Hand-held Measuring Device XC250 - Model No. 5725.00 Excellent accuracy of temperature and relative humidity. Contact-free temperature measurement. Display of calculations and statistical functions. Adjustment of local pressure and local height possible. Calibration function and offset correction. Including a calibration certificate. USB interface with SmartGraph3 software. 11 23 3 Technical data Dimensions 6 /16" x 2 /64" x 1 /8" (170 x 60 x 35 mm) Weight approx. 8.8oz. (250g) Temperature sensor Principle NTC. Measurement range -4 ° - 122 °F (- 20 … +50 °C) Accuracy ±0.2 °C (0…40 °C) otherwise ±0.4 °C. Resolution 0.1 °C Surface Temperature Principle Thermopile. Measurement range: -70 - 380 °C Unit °C. Accuracy ±0.5 °C (0 - 50 °C) otherwise ±4 °C. Resolution 0.1 Principle Capacitive. Measurement range: 0 - 100%RH Accuracy ±2% RH. Resolution 0.1% RH. Humidity Sensor 3 Calculations Dew point temperature °C or °F. Absolute humidity g/m . Mixed Display ratio g/kg or gr/lb Statistical calculations MAX, MIN, HOLD, AVG, ACT. Temperature Functions correction and humidity correction factors (offset) Permitted ambient -4 ° - 140 °F (- 20 … +60 ° C) Storage conditions temperature Permitted rel. humidity <95%RH non-condensing Permitted ambient Operating conditions temperature -4 ° - 122 °F (- 20 … +50 ° C) Permitted rel.
Recommended publications
  • Mold, Moisture, and Houses – Ventilation Is an Effective Weapon 1 June 2009
    Mold, Moisture, and Houses – Ventilation is an Effective Weapon 1 June 2009 MOLD, MOISTURE, AND HOUSES – VENTILATION IS AN EFFECTIVE WEAPON This guideline document provides an overview of residential mold prevention in plain language that may be understood by the average consumer – the resident of today’s North American housing. It provides a basic scientific explanation of mold fundamentals, findings related to problems blamed on mold, and an introduction to psychrometrics - the science of air containing moisture. That scientific base is then applied as a general guideline for making the practical decisions associated with residential design, construction, ventilation and operation for effective mold control. Written by: David W. Wolbrink With inputs from: Rick Olmstead, Paul H. Raymer, Donald T. Stevens, John Ehlen, James D. Boldt, Daniel T. Forest, Gord Arnott, Joel Borque Home Ventilating Institute 1000 North Rand Road, Suite 214 Wauconda, IL 60084 USA Phone: 847.526.2010 Fax: 847.526.2993 e-mail: [email protected] Website: www.hvi.org Copyright © 2009 Home Ventilating Institute TABLE OF CONTENTS 1. Executive Summary........................................................................................ 2 2. Introduction to This Guideline......................................................................... 3 3. Mold: Friend and Enemy................................................................................. 4 4. Moisture and Air Around Us............................................................................ 7 5. The House:
    [Show full text]
  • Museum Collections Environment
    Chapter 4: Museum Collections Environment A. Overview.................................................................................................................................. 4:1 What information will I find in this chapter? .................................................................................. 4:1 Who should read this chapter? ................................................................................................... 4:1 What are the agents of deterioration that affect the museum environment? ................................... 4:1 B. Developing the Critical Eye...................................................................................................... 4:3 What is the "critical eye?" ........................................................................................................... 4:3 What kinds of materials will I find in a museum collection?............................................................ 4:4 What is deterioration? ................................................................................................................ 4:5 What is chemical deterioration? .................................................................................................. 4:6 What is physical deterioration? ................................................................................................... 4:6 What is inherent vice? ................................................................................................................ 4:7 Why is it important to understand the environmental
    [Show full text]
  • Methods of Measuring Humidity and Testing Hygrometers
    NBS CIRCULAR Methods of Measuring Humidity and Testing Hygrometers UNITED STATES DEPARTMENT DF COMMERCE NATIONAL BUREAU OF STANDAROS PERIODICALS OF THE NATIONAL BUREAU OF STANDARDS As the principal agency of the Federal Government for fundamental research in physics, chemistry, mathematics, and engineering, the National Bureau of Standards conducts projects in fourteen fields: electricity, optics, metrology, heat and power, atomic and radiation physics, chemistry, mechanics, organic and fibrous materials, metallurgy, mineral products, building technology, applied mathematics, electronics, and radio propagation. The Bureau has custody of the national standards of measurement, and conducts research leading to the improvement of scientific and engineering standards and of tech- niques and methods of measurement. Testing methods and instruments are developed; physical constants and properties of materials are determined; and technical processes are investigated. Journal of Research Internationally known as a leading scientific periodical, the Journal presents research papers by author- ities in the specialized fields of physics, mathematics, chemistry, and engineering. Complete details of the work are presented, including laboratory data, experimental procedures, and theoretical and mathe- matical analyses. Each of the monthly issues averages 85 two-column pages; illustrated. Annual subscription: domestic, $5.50; foreign, $6.75. Technical News Bulletin Summaries of current research at the National Bureau of Standards are published each month in the Technical News Bulletin. The articles are brief, with emphasis on the results of research, chosen on the basis of their scientific or technologic importance. Lists of all Bureau publications during the preceding month are given, including Research Papers, Handbooks, Applied Mathematics Series, Building Materials and Structures Reports, Miscellaneous Publications, and Circulars.
    [Show full text]
  • Humidity Vaisala Humicap® Sensor for Measuring Relative Humidity
    Humidity / TECHNOLOGY DESCRIPTION Vaisala HUMICAP® Sensor for Measuring Relative Humidity ® In 1973, Vaisala introduced HUMICAP , the world’s first thin- HUMICAP in Brief film capacitive humidity sensor. Since then, Vaisala has Box headline here ▪ A capacitive thin-film polymer become the market leader in relative humidity measurements, sensor and thin-film capacitive humidity sensors have developed from ▪ Full measurement range one company’s innovation into a global industry standard. 0...100 %RH ▪ Accurate to ±1 %RH Vaisala HUMICAP sensors guarantee the dielectric properties of the ▪ Traceable humidity quality and reliability, with their polymer film change, and so does measurement reputation for accuracy, excellent the capacitance of the sensor. The ▪ Nearly 40 years on the market long-term stability, and negligible instrument’s electronics measure hysteresis. the capacitance of the sensor and convert it into a humidity reading. HUMICAP’s Unique Benefits How It Works ▪ Excellent long-term stability HUMICAP is a capacitive thin-film Typical Applications for Insensitive to dust and most polymer sensor consisting of a Humidity Measurement ▪ chemicals substrate on which a thin film of Vaisala’s humidity instruments with polymer is deposited between two HUMICAP sensors are suitable for ▪ Chemical purge option for stable measurements conductive electrodes. The sensing a wide range of applications. From in environments with high surface is coated with a porous power and steel to life sciences and concentrations of chemicals metal electrode to protect it from building automation, many industries contamination and exposure to need to measure humidity – here are ▪ Sensor heating for measurements even in condensation. The substrate is just a few: condensing environments typically glass or ceramic.
    [Show full text]
  • The Dehumidification Handbook, Third Edition
    The Dehumidification Handbook Third Edition ISBN 0-9717887-0-7 Copyright 1989, 2002 and 2019 © Munters Corporation The Dehumidification Handbook Third Edition Copyright 1989, 2002 and 2019 © Munters Corporation Reuse Of This Material For book reviews and personal educational and professional use, readers are encouraged to excerpt or photocopy and distribute any useful portion of this handbook, provided that the source of the material is appropriately referenced and the Munters copyright is acknowledged. For electronic distribution or if the material will be included in any printed publication, Munters Corporation must provide written authorization in advance of publication. For those uses, please contact Munters Corporation Marketing Department by mail at 79 Monroe Street, Amesbury, MA 01913, or by email at [email protected]. Disclaimer Although great care has been taken in the compilation and publication of this book, no warranties either expressed or implied are given in connection with the material. Neither the contributors nor the publisher take any responsibility whatsoever for any claims arising from its use. The entire risk of the use of this information is assumed by the user. However, to improve future editions, the publisher welcomes any and all comments, corrections or suggestions from readers. CONTRIBUTORS We would like to express our gratitude to Lew G. Harriman III as editor of the first two editions of this book and for guiding this work with interest. Also, we would like to thank the following original contributors and 1989 Editorial Advisory Board members for their work; Enno Abel, Nick Baranov, Bruce Bonner, Steven Brickley, Luiz Felipe de Carvalho, Douglas Kosar, Hansi Kruger, Ralph Lahmon, Milton Meckler, Mohamed Moledina, Terry Penny, Ing.
    [Show full text]
  • Handheld Temperature/ Humidity Indicator Model RH31
    Handheld Temperature/ Humidity Indicator Model RH31 Features U Simultaneous U Data Hold Function The RH31 digital Digital Display of Both Provided thermo-hygrometer is compact Temperature and U C/ F Switchable and easy to use and has Humidity U features of simultaneous Power Auto-Off Function display of temperature and U Display of Relative Provided humidity, selectable display Humidity, Dew-Point U Model with Memory of relative humidity, dew-point Temperature and Function are Available temperature, wet-bulb Wet-Bulb Temperature (RH31-RS232) temperature, and data hold. is Selectable (Temperature, Humidity, The RH31-RS232 has an U Interchangeable Measuring Time) RS-232C serial communications Sensors with Connectors interface for datalogging to a x 1500 Data Points. computer. Specialized humidity sensors– general type, thin type and separated type – are interchangeable. Units RH31 Series are °C/ °F switchable by internal jumper. $ RH31-RS232 420 shown with Basic Model optional sensors RH31 Hu-11 Model RH31 Display Part RH31-RS232 Indication of temperature, Specifications humidity, unit and battery shortage mark and Features Power switch Specifications Hold key RH31 Meter Measuring range: Read key Transmission Temperature: –10 to 60°C of data storage Relative humidity: 0 to 100% RH to personal computers Accuracy rating: Clear key Temperature: Write key ±(0.1% of measured value +0.2°C) Setting of Relative humidity: current time and data General type sensor ±(0.1% of measured value +0.2% RH) storage Dew-point temperature: ±1.0°C starting Wet-bulb
    [Show full text]
  • Humidity, Pressure and Carbon Dioxide Measurement for Low Dewpoint OEM Measurements Using the HMP228 Transmitter for Measuring I
    40234Ymi_Vaisala154 8.9.2000 20:22 Sivu 1 154/2000154/2000 Humidity, pressure and carbon dioxide measurement The New Vaisala DMT242 Dewpoint Transmitter For Low Dewpoint OEM Measurements Vaisala’s ppm Calculation of Moisture in Transformer Oil Using the HMP228 Transmitter PTB210 Series Digital Barometers For Measuring in Extreme Environments Outdoor Plant Growth Experiments In the Elevated CO2 Atmospheres in Japan 40234Ymi_Vaisala154 8.9.2000 20:23 Sivu 2 Contents Presidents’ Column 3 Dewpoint Vaisala has been awarded a contract by the Meteorological Low Dewpoint OEM Measurements 4 Service of Canada (MSC). Humidity Expressed as Dewpoint Temperature 6 Vaisala supplies electronic station barometers to replace U.S. National Weather Service Awards the mercury barometers Dewpoint Contract to Vaisala 8 currently used for weather observation throughout Humidity Canada. The PTB220 digital barometer is easy to maintain, Industrial Humidity Measurements 8 and can be exposed to Reliable Performance in Humid Air extremes of temperature Conditioning Applications 10 between -20 and +60 °C. Improved Maintenance for Transformers 11 Using Automated Long-Term Monitoring of Relative Humidity 13 Carbon dioxide is used to Vaisala Sensor in Radio Telemetry carbonate the beverages in the Instrumentation Systems 16 production of soft drinks. In the United States, OSHA Pressure requires that the carbon Reliable Barometric Pressure Measurement dioxide level remains at, or in All Wind Conditions 18 below, 5,000 ppm in the atmosphere of any filler room PMI20 Digital Barometer Display area. Big Springs Inc. is a - Perfect Partner for Vaisala’s Barometers 20 major soft drink manufacturer Measuring for Extreme Environments and a large local Coca-Cola franchise distributor located in Using PTB210 Barometers 21 Huntsville, Alabama.
    [Show full text]
  • Humidity Dial Indicators
    Registration Web Table-of-Contents Humidity HU Dial Indicators Thermohygrometer Thermohygrometer Wall Clock Easy-to-read dial indicators for both Clock displays time, humidity, and temperature temperature and humidity This attractive silver rim and black face multiparameter wall meter Monitor conditions of your lab, displays time, humidity, and office, or food storage area temperature. Easily view with this economical thermo- time, humidity, hygrometer. Displays in °F and °C. or temperature No batteries or external power from separate are required for operation. measurement dials. Temperature is displayed in °F and °C. What’s included: one AA battery. 35700-10 37803-25 Specifications & Ordering Information Specifications & Ordering Information Response time: 1 minute Dimensions: 5" dia x 11/8"D Response time: 1 minute Power: one AA battery (included) Display: analog Display: analog Dimensions: 93/4" dia x 11/2"D Mode RH Temperature Mode RH Temperature Range 25 to 80% –4 to 104°F (–20 to 40°C) Range 0 to 100% –40 to 120°F (–40 to 50°C) Resolution 1% 2°F/1°C Resolution 0.1% 2°F/1°C ±5% from 25 to 70% Accuracy ±3.6°F/±2°C ±8% from 71 to 80% Accuracy ±3% of reading ±4°F (±2°C) Catalog number Description Price Catalog number Description Price KH-35700-10 Thermohygrometer KH-37803-25 Thermohygrometer wall clock Accessories KH-09376-01 Replacement batteries, 1.5 V, AA. Thermohygrometer Pack of 4 EK-17030-20 Calibration service; NIST-traceable certificate, three with Large Dial humidity and one temperature test points Large 10" dial display allows you to view temperature from a distance Thermohygrometer View temperature conditions from a distance with the with Glass Thermometer big 10" diameter thermohygrometer.
    [Show full text]
  • Thermodynamics Lab
    Universität Duisburg-Essen 4. Semester Fak. 5 , IVG Fachgebiet Thermodynamik Laborleiter: Dr. Siddiqi Thermodynamics Lab Humidity Measurement 1 Humidity Measurement Introduction Air comprises a mixture of gases of which nitrogen makes up more than 78%, oxygen 21% and carbon dioxide and the inert gases (argon, neon, krypton, helium etc.) the remainder. These are known as the dry gases of the atmosphere. In addition to these dry gases, the air also contains varying amounts of water vapor. At normal temperatures and pressures water is able to exist in both a liquid and a gaseous (or vapor) form, but it cannot be treated in the same way as the other gases of the atmosphere because its quantity, and hence proportion are continually varying. Water vapor is said to be associated with dry air and the more vapor associated with the dry gases, the more humid the air. Humidity measurements are important not only in meteorology but also in pulp and paper industry, drug and food storage and delivery, film industry etc. Hygroscopic materials draw water from their surroundings and can form solution (e.g., salt, sugar). Strongly hygroscopic materials are used directly for the drying of substances (e.g., gases). The humidity can have dramatic effect on our perception of comfort. It can affect the well-being of a person or even cause diseases. A measure of the water vapor content in the air is the absolute humidity (Feuchte). It shows how many kg of water vapor are present in unit volume (1 m3) of the gas mixture. Depending on the state of the gas mixture (dry or wet) taken as reference one defines: a) Related to the unit volume of the wet gas mixture m kg O = f ′ = W H 2 ′ 3 V m wet air (1a) mw = Mass of water vapor V ′ = Volume of wet gas mixture (slash means here that it is the wet gas mixture) ′ f is also called the density of the water vapor.
    [Show full text]
  • Humidity / Temperature / Dew Point / Carbon
    HUMIDITY / TEMPERATURE / DEW POINT / CARBON DIOXIDE / MOISTURE IN OIL / DISSOLVED GAS ANALYSIS IN TRANSFORMER OIL / PRESSURE / WEATHER / SERVICE OFFERING Humidity and Temperature / TECHNOLOGY DESCRIPTION Vaisala HUMICAP® Sensor for Measuring Relative Humidity ® In 1973, Vaisala introduced HUMICAP , the world’s first thin- HUMICAP in Brief film capacitive humidity sensor. Since then, Vaisala has Box headline here ▪ A capacitive thin-film polymer become the market leader in relative humidity measurements, sensor and thin-film capacitive humidity sensors have developed from ▪ Full measurement range one company’s innovation into a global industry standard. 0...100 %RH ▪ Accurate to ±1 %RH Vaisala HUMICAP sensors guarantee the dielectric properties of the ▪ Traceable humidity quality and reliability, with their polymer film change, and so does measurement reputation for accuracy, excellent the capacitance of the sensor. The ▪ Nearly 40 years on the market long-term stability, and negligible instrument’s electronics measure hysteresis. the capacitance of the sensor and convert it into a humidity reading. HUMICAP’s Unique Benefits How It Works ▪ Excellent long-term stability HUMICAP is a capacitive thin-film Typical Applications for Insensitive to dust and most polymer sensor consisting of a Humidity Measurement ▪ chemicals substrate on which a thin film of Vaisala’s humidity instruments with polymer is deposited between two HUMICAP sensors are suitable for ▪ Chemical purge option for stable measurements conductive electrodes. The sensing a wide range of applications. From in environments with high surface is coated with a porous power and steel to life sciences and concentrations of chemicals metal electrode to protect it from building automation, many industries contamination and exposure to need to measure humidity – here are ▪ Sensor heating for measurements even in condensation.
    [Show full text]