Best Practice Guide to Cable Ladder and Cable Tray Systems Channel Support Systems and other Associated Supports November 2012 BEAMA Best Practice Guide to Cable Ladder and Cable Tray Systems Including Channel Support Systems and other Associated Supports Companies involved in the preparation of this Guide Contents INTRODUCTION 5 DEFINITIONS AND ABBREVIATIONS 6 1. Packing Handling and Storage 8 1.1 General Packing and Handling 8 1.2 Loading and offloading recommendations 9 1.3 Storage 11 2A. Installation of the system 12 2.1 Common tools for Installation 12 2.2 Structural characteristics 12 2.3 Support Systems 18 2.4 Straight cable ladder and cable tray lengths 29 2.5 Coupler types (refer to manufacturer’s literature) 32 2.6 Fixings 36 2.7 Fittings 36 2.8 Accessories 39 2.9 Site modification 39 2.10 Earth protection and EMC 40 2B. Installation of Cable 41 2.11 Preparation 41 2.12 Wiring Regulations 41 2.13 Power Cables 41 2.14 Data Cables 46 2.15 Expansion 46 2.16 Electro Mechanical Effects 46 3. Environment 48 3.1 Selecting the right material and finish 48 3.2 Finishes 56 3.3 Non-Metallic systems 61 3.4 Loadings 63 3.5 Temperature 65 4. Health & Safety 67 5. Maintenance 68 5.1 Inspection 68 5.2 Removal of cables 68 5.3 On site repairs 68 6. Sustainability 69 6.1 Sustainable development 69 6.2 REACH regulations 69 6.3 The management of WEEE and RoHS 69 6.4 Environmental footprint 70 7. Applicable Standards 71 Companies involved in the preparation of this Guide 72 FIGURES Figure 1: Methods of removal 9 Figure 2: Loaded beams 13 Figure -
Lecture 5: Electrical Supply and Distribution
Lecture 5: Electrical Supply and Distribution 5.1 Single Phase Electric Power There is only one phase, i.e. the current flows through only one wire and there is one return path called neutral line to complete the circuit. Single-phase comes to the home with two wires: active and neutral. The neutral wire is connected to earth (water pipe, earth stake, etc.) at the switchboard. Single-phase distribution is used when loads are mostly lighting and heating, with few large electric motors. Single-phase power is: Able to supply ample power for smaller customers, including homes and small, non- industrial businesses. Adequate for running motors up to about 10kw; a single-phase motor draws significantly more current than the equivalent 3-phase motor, making 3-phase power a more efficient choice for industrial applications. 5.2 Three Phase Electric Power It is the Polyphase system where three phases are send together from the generator to the load. Each phase are having a phase difference of 120°, i.e. 120° angle electrically. Therefore, from the total of 360°, three phases are equally divided into 120° each. The power in three-phase system is continuous as all the three phases are involved in generating the total power. Three-phase has four wires: three actives (called phases) and one neutral. The neutral wire is earthed at the switchboard. 3-phase power is: Common in large businesses, as well as industry and manufacturing. Large domestic installations sometimes have three-phase because it distributes the total load in a way that ensures that the current in each phase is lower. -
Answer the Purpose: 4
Page 26 1. CONDUCTORS Conductors are defined as materials that easily allow the flow of _________. Metals are _______ conductors while insulators are ______ . The 2 common metals used for conductors in the electrical trade are: ___________ and ______________. Aluminium has become more prevalent for larger C.S.A. conductors as it is cheaper and lighter but more brittle than copper. Current/ Copper/ Aluminium Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth. In mainland Europe, a round equivalent is more common. Flat cables (or festoon cables) are made in PVC and Neoprene and are used as trailing cables for cranes, open filed conveyors and shelve service devices. Flat cables offer the advantages of extremely small bending radius’s, high flexibility and minimum wastage of space. Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth. -
EDS 05-2010 Main Substation Feeder and Ring Main Unit Protection
Document Number: EDS 05-2010 Version: 4.0 Date: 02/12/2015 ENGINEERING DESIGN STANDARD EDS 05-2010 VALIDITY BEFORE USE BEFORE VALIDITY MAIN SUBSTATION FEEDER AND RING MAIN UNIT S PROTECTION SETTINGS (LPN) Network(s): LPN Summary: This standard describes the protection settings for main substation feeders and ring main units in the LPN area. Owner: Kevin Burt Date: 02/12/2015 ADER MUST CONFIRM IT CONFIRM MUST ADER Approved By: Barry Hatton Approved Date: 08/01/2015 This document forms part of the Company’s Integrated Business System and its requirements are mandatory throughout UK Power Networks. Departure from these requirements may only be taken with the written approval of the Director of Asset Management. If you have any queries about this document please contact the author or owner of the current issue. Applicable To UK Power Networks External All UK Power Networks G81 Website Asset Management Contractors RE THE DOCUMENT, LED Capital Programme ICPs/IDNOs Connections Meter Operators HSS&TT Network Operations UK Power Networks Services Other THIS IS AN UNCONTROL AN IS THIS Document Number: EDS 05-2010 Version: 4.0 Date: 02/12/2015 E Revision Record Version 4.0 Review Date 08/01/2019 Date 02/12/2015 Author Kevin Burt Why has the document been updated – Periodic review What has changed – No content changes Document transferred onto a new template and rules applied S VALIDITY BEFORE US BEFORE VALIDITY S Version 3.2 Review Date 09/11/2015 Date 04/09/2012 Author Lee Strachan Document reviewed for publishing on G81 website Version 3.1 Review Date 09/11/2015 Date 25/08/2011 Author Chris Anderson Reclassified from EI to EDS Version 3.0 Review Date 09/11/2015 Date 19/08/2010 Author David G Edwards IT CONFIRM MUST ADER Rebranded, reviewed and review date extended Version 2.0 Review Date Date 30/10/2006 Author David G Edwards TLF ratings and revised ACB protection settings added Tables (6A and 11A) Version 1.0 Review Date Date 07/04/2004 Author David G Edwards Original, based on Protection Standard Number E 7/6 P 6/1 revision 4. -
BICC Industrial Cables Catalog
TECHNICAL INFORMATION Click here for Table of Contents 9. Technical Information Click the BICC logo above to return to the Section Index TECHNICAL INFORMATION 9.i BICC Cables has made every effort to ensure the accuracy of the information provided in this catalog, however, we cannot be responsible for errors, omissions, or changes due to obsolescence. All data herein is subject to change without notice. Data and suggestions made in this catalog are not to be construed as recommendations to use any product in violation of any government law or regulations relating to any material or its use. EFFECTIVE 1998-09-30 TABLE OF CONTENTS 9. Technical Information Glossary..........................................................................................9.01-9.07 Reference Standards........................................................................9.08-9.16 Cable Handling and Storage ...........................................................9.17-9.20 Cable Pre-Installation..............................................................................9.21 Cable Installation............................................................................9.22-9.28 Cable Testing ..................................................................................9.29-9.32 Common Color Sequence........................................................................9.33 Metric Conversion ..................................................................................9.34 Copper Short Circuit Currents................................................................9.35 -
Electric Cooktop Installation Instructions
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. IMPORTANT INSTALLATION INFORMATION • All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only electrical supply with ground. • Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm). For Standard Installation: * 30" (76.2 cm) min. for unprotected cabinet 24" (61 cm) min. for protected surface 30" Min. * (76.2 cm) B Cooktop Dimensions A C 4"X 8" (10.2 cm x 20.3 cm) opening to route armoured cable. Cooktop Cutout Dimensions 7¼" (18.4 cm) H*** E F D G 1" (2.5 cm) 35 1/8" (89.2 cm) **Note: D & E are critical to the proper installation of the cooktop. Please make sure to respect those Do not slide unit into cabinet cutout. dimensions. D reflects a finished dimension it is Protruding screws on the bottom of recommended to undercut this dimension and unit may damage the bottom front adjust upon installation of the appliance due to the finish. Figure 1 variation in countertop materials. CUTOUT DIMENSIONS H. DEPTH BELOW MODEL A. LENGTH B. WIDTH C. DEPTH LENGTH WIDTH COOKTOP*** D** E** FG 7 15 3 1 1 36 (91.4 ) 35 /8 (91.1) 25¾ (65.4) 7¾ (19.7) 35 /16 (91.3) 35 /16 (89.4) 22 (55.9) 1 /8 (2.9) Max. -
Pdf Grade 11 Physics Week 6 Lesson 2
Ministry of Education Secondary Engagement Programme Grade 11 Physics WEEK 6 Lesson 2 Topic: Electricity Sub-topic: Electricity in Home Objective: Given information and with the aid of diagrams, students will: i. discuss the reasons for using parallel connections of domestic appliances; ii. explain the purpose of a fuse or circuit breaker and the earth wire; iii. select a fuse or circuit breaker of suitable current rating for a given appliance; iv. state the adverse effects of connecting electrical appliances to an incorrect or fluctuating voltage supply. Content: Distributing electricity Electrical energy is most efficiently generated and distributed using alternating current. Most Caribbean countries, and also the USA, utilize an a.c. frequency of 60 Hz. A few territories use a frequency of 50 Hz. Minimizing Power Loss When current travels along a wire, the wire becomes hot and heat energy is lost to the atmosphere. Power is lost according to the formula P = I2 R where P is the power lost, I is the current in the wire and R is the resistance of the wire To minimize power loss, two approaches are used in distribution systems. i. Keep the resistance (R) of the conducting wires as small as possible. The transmission wires, therefore, have larger diameters, since thick wires have less resistance per unit length than thin wires. ii. A second approach is to use small currents in the wires. To achieve this, the power is sent at very high voltages. Household electric circuits Parallel wiring 68 Ministry of Education Secondary Engagement Programme Grade 11 Physics Parallel wiring is used in household circuits rather than series connections so that appliances can be controlled individually without affecting other devices. -
The Testing of Electrical Installations
2014 HellermannTyton South Africa Compliance Testers Compliance Test Kits TCTRP TCTDT TCTCDK Description Analogue Digital Digital Kit Kit Kit DMM TBM811 - - Clamp Meter - TBM3030 TBM3030 Insulation Tester T1800 T1851 T1151 Earth Resistance T1805 T1820 T1120 Loop Tester T1825 T1825 T1125 ELCB Tester TEL1TLB TEL1TLB TEL1TLB Phase Rotation T860 T887 T890 Foam TCTRPFM TCTDTFM TCTCDKFM Case TCTCS TCTCS TCTCS Refer to pages 19-24 for Technical Specifications Compliance Combination Tester Model T419 | T89 All the above testers featured in a single lightweight compliance combination tester • Continuity (Low OHM) • Insulation (50/100/250/500/1000 V) • Loop impedance • Earth resistance (resistivity) • ELCB (sensitivity & time) • RS232 Interface or USB • Frequency/Voltage • Phase Rotation • 350 Memory Locations Johannesburg Durban Cape Town Port Elizabeth i (011) 879-6620 (031) 569-9900 (021) 594-7100 (041) 408-2400 Index 1. WHAT IS AN ELECTRICAL INSTALLATION? 1 2. WHO IS RESPONSIBLE? 1 3. HOW CAN A LAYMAN KNOW IF THE INSTALLATION IS SAFE? 1 4. WHERE TO OBTAIN A CERTIFICATE OF COMPLIANCE? 1 5. WHAT MUST BE DONE BEFORE ISSUING A CERTIFICATE OF COMPLIANCE? 1 6. WHAT ELECTRICAL TEST MUST BE CARRIED OUT? 1 Tests to be done 7. CONTINUITY OF ALL BONDING CONDUCTORS 1/2 8. RESISTANCE OF EARTH CONTINUITY CONDUCTOR 2 9. CONTINUITY OF RING CIRCUIT (IF APPLICABLE) 4 10. ISOLOCK TESTER 5 11. EARTH LOOP IMPEDANCE TEST: MAIN SWITCH 4/6 12. ELEVATED VOLTAGE ON NEUTRAL 10 13. EARTH ELECTRODE RESISTANCE (IF REQUIRED) 10 14. INSULATION RESISTANCE 14 15. VOLTAGE (MAIN DB) NO LOAD 14 16. VOLTAGE (MAIN DB) ON LOAD 14 17. VOLTAGE AT AVAILABLE LOAD (WORST CONDITION) 14 18. -
Huawei Data Center Facilities Solutions
Power ICT in a Smart Way Huawei Data Center Facilities Solutions HUAWEI TECHNOLOGIES CO., LTD. Contents Modular Data Center ���������������������������������������������������������������� 05 Prefabricated Data Center �������������������������������������������������������� 17 Huawei Datacenter Facility Management System ��������������������� 29 Global Applications ������������������������������������������������������������������� 31 Indoor Modular Data Center FusionModule2000&5000 FusionModule800 Outdoor Prefabricated Data Center FusionModule1000B FusionModule1000A Modular Data Center FusionModule5000 Smart Modular Data Center Introduction HUAWEI FusionModule5000 is a new generation smart modular data center solution with complete integration of cabinets, power supply and distribution systems, cooling systems, cabling systems, management software, and other subsystems. It supports flexible deployment with single or dual row, cold or hot aisle containment. The maximum IT power can be up to 21kW/rack. Application Scenarios • Maximum IT power per module can be up to 310kW, which meet FusionModule5000 (Dual-row) the requirements of large-scale data center for industries like ISP, government, education, healthcare, finance, telecom, etc. • Designed for chilled water cooling scenarios. Features & Value Reliable • Single/dual power supply, Tier IV supportive, Precise monitoring of power branch temperature prevents fire caused by loose contact and overheat • Water leakage monitoring keeps room away from flooding • Ring network of monitoring system -
House Wiring and Dirty Electricity
Your low EMF Home 1. House wiring © Alasdair and jean Philips 2.11.17 Your low EMF Home Articles Your low EMF Home set of articles is separated into 9 sections, each of which can be individually downloaded. It is a 'work in progress' incorporating new information whenever time permits. Section 1 House wiring and EMFs; July 2007 SAGE report 1. House wiring and EMFs; introduction; what are normal EMFs? Choosing a consumer unit; electric fields; cables; demand switches; external ‘faults’ in the supply that can cause high magnetic fields; Wiring in homes - SAGE report July 2007 2. Dirty electricity (DE) – What is dirty electricity? What effect does it have? What sort of levels are you likely to have? What you can do if you have high levels of DE; DE coming into the house; DE generated within the house; dLAN caution 3. Lighting and EMFs; Bulbs, incandescent, energy-saving, fluorescent, halogen, full- spectrum light, daylight, light emitting diode (LED); anglepoise lamps and other metal framed lamps, halogen desk lamps, bedside/bedhead lights, spotlights, standard lamps and table lamps, nightlights; light wiring; light switches, dimmer switches; Physiological effects of blue and red lights; circadian rhythms, melatonin, light and illness, timing of blue lights, timing of red/amber lights 4. Smart meters – What is it all about? Smart Grid; Remote reading meters; Smart meters; Wide Area Network (WAN) technologies; Home Area Network (HAN); RF exposures from Smart Meters; Experiences of smart meters in other countries; Solar storms may affect smart -
Technical Data 20 Amp 20 AX Switches
Technical Data 20 Amp 20 AX Switches Brief product description: Features: A range of IP rated accessories designed to protect • Clearly marked terminals with backed out the potentially dangerous electricity supply in the most captive screws for easy installation arduous of conditions • 20 Amp, 20AX inductive rated • Covers to seal the fixing screws • Earth terminal in mounting box • All cable entries in the 4 sides have removable blanking caps. • Housing will accept alternative switch modules from the Grid range • Neon indicator that can be wired to illuminate when off or on depending on wiring blanking caps. Product Images WP12 / WP30 WP14 WP42 WP42 Rear View WP12/30/42 Side View Technical Specifications Standard(s) BS EN 60669-1 Rating 20 Amp 250V~ (20AX - no derating for inductive or fluorescent loads) Switch Type Single pole (WP12, WP14, WP42 products) Double pole (WP30 products) Contact Gap 3.0mm minimum Terminal Capacity 4 x 1.0mm² 4 x 1.5mm² 2 x 2.5mm² 1 x 4.0mm² IP Rating IP66 RoHS Directive No WEEE Directive No Number of 20mm cable entries 5 x 20mm. 1 in each of 3 sides and 2 in the remaining side 1 drill out entry 20/25mm in rear face Size 91mm x 91mm x 67mm 20 Amp 20 AX Switches Line Diagrams 1 4 9 4 91 67 44 WP12 / WP30 1 4 9 4 91 67 44 WP14 4 1 4 9 91 67 44 WP42 Packaging Information Cat No. Description Packaging Type Pack Quantity Barcode Product Inner Box Outer Box Each Inner Outer Individual Inner Box Outer Box Box Box WP12 20A 1G, 2 Way Printed Box / Printed Outer Box 1 / 10 5050765022132 / 5050765022231 WP42 20A 2G, 2 Way Printed Box / Printed Outer Box 1 / 10 5050765022149 / 5050765022248 WP14 20A 1G, 1W, "PRESS" Printed Box / Printed Outer Box 1 / 10 5050765022156 / 5050765022255 WP30 20A 1G, Double Pole Printed Box / Printed Outer Box 1 / 10 5050765022163 / 5050765022262 Weights & Dimensions Cat No. -
Hybrid Ring/Radial Final Circuits
PE NICEIC OCTober 2015:Layout 1 06/08/2015 15:13 Page 1 TECHNICAL ADVICE taking you step by step through procedures and requirements for electrical installations Hybrid ring/radial final circuits ICEIC is sometimes asked whether a ring Ring circuit cable (installed rating 20 A min) final circuit has to be Nsupplied directly from Ring !nal circuit a protective device in the distribution board or consumer unit, or whether it is permitted to supply the two ends of the Junction box (or possibly double-pole switch or contactor) rated at 30/32 A min ring via a dedicated radial circuit Cable connected to 30/32 A overcurrent protective device Radial circuit cable cable, as shown in Fig. 1, in consumer unit (installed rating 30/32 A min) thereby forming a hybrid L OUT N ring/radial circuit. OUT This question can arise where, for example, the contractor wishes to Consumer unit make use of a redundant radial circuit cable previously installed for another Fig 1 Typical ring final circuit supplied via a radial circuit cable, purpose (such as a cooker circuit) to forming a hybrid ring/radial circuit supply a ring final circuit, or where a Periodic Inspection of an existing hybrid circuit, the ‘single point of of the socket-outlets ( I⌬n ≤ 30 mA) in installation reveals such an supply’ is the point at which the two accordance with Regulation 411.3.3. arrangement. ends of the ring part of the circuit are Also, if any part of the circuit cable connected to the radial part (that is, at The same question may also arise is concealed in a wall or partition, it the junction box, switch or contactor as where the contractor wishes to control must be provided with additional labelled in Fig 1).