Strontium Sulfate Scale Prevention

Total Page:16

File Type:pdf, Size:1020Kb

Strontium Sulfate Scale Prevention Tech Manual Excerpt Water Chemistry and Pretreatment Strontium Sulfate Scale Prevention Strontium Calculation /8/ Sulfate Scale Prediction of SrSO scaling potential is performed in the same way as the previously Prevention 4 described procedure for CaSO4: 1. Calculate the ionic strength of the concentrate stream (Ic) following the procedure described in Scaling Calculations (Form No. 45-D01551-en): Eq. 1 2. Calculate the ion product (IPc) for SrSO4 in the concentrate stream: Eq. 2 where: m 2+ 2+ ( Sr )f = M Sr in feed, mol/L m 2– 2– ( SO4 )f = M SO4 in feed, mol/L 3. Compare IPc for SrSO4 with the solubility product (Ksp) of SrSO4 at the ionic strength of the concentrate stream, Figure 1 in Calcium Fluoride Scale Prevention (Form No. 45-D01556-en). If IPc ≥ 0.8 Ksp, SrSO4 scaling can occur, and adjustment is required. Adjustments for SrSO4 Scale Control The adjustments discussed in Calcium Sulfate Scale Prevention (Form No. 45-D01553-en) for CaSO4 scale control apply for SrSO4 scale control as well. Page 1 of 2 Form No. 45-D01555-en, Rev. 4 April 2020 Excerpt from FilmTec™ Reverse Osmosis Membranes Technical Manual (Form No. 45-D01504-en), Chapter 2, "Water Chemistry and Pretreatment." Have a question? Contact us at: All information set forth herein is for informational purposes only. This information is general information and may differ from that based on actual conditions. Customer is responsible for determining whether products and the information in this document are www.dupont.com/water/contact-us appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries. Please note that physical properties may vary depending on certain conditions and while operating conditions stated in this document are intended to lengthen product lifespan and/or improve product performance, it will ultimately depend on actual circumstances and is in no event a guarantee of achieving any specific results. DuPont assumes no obligation or liability for the information in this document. References to “DuPont” or the “Company” mean the DuPont legal entity selling the products to Customer unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. No freedom from infringement of any patent or trademark owned by DuPont or others is to be inferred. DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, ℠ or ® are owned by affiliates of DuPont de Nemours Inc. unless otherwise noted. © 2020 DuPont. Page 2 of 2 Form No. 45-D01555-en, Rev. 4 April 2020.
Recommended publications
  • The Chemistry of Strontium and Barium Scales
    Association of Water Technologies October 20 -23, 2010 Reno, NV, USA The Chemistry of Strontium and Barium Scales Robert J. Ferguson and Baron R. Ferguson French Creek Software, Inc. Kimberton, PA 19442 (610) 935-8337 (610) 935-1008 FAX [email protected] [email protected] Abstract New ‘mystery scales’ are being encountered as cooling tower operators increase cycles to new highs, add ‘reuse’ water to the make-up, and utilize new make-up water sources as part of an overall water conservation strategy. Scales rarely, if ever, encountered in the past are emerging as potential problems. This threat of unexpected scale is compounded because most water treatment service companies do not include barium and strontium in their make-up water analyses. Water sources with even as little 0.01 mg/L of Ba (as Ba) can become very scale-forming with respect to barite (BaSO4) when tower concentration ratios are increased and sulfuric acid used for pH control. Make-up waters incorporating reverse osmosis concentrate can also provide a strontium and barium source. In some cases, produced waters are also being used in an effort for greener water use. This paper discusses the chemistry of the barium and strontium based scales barite (BaSO4), celestite (SrSO4), witherite (BaCO3) and strontianite (SrCO3). Conditions for formation and control from a water treater’s perspective are emphasized. Indices for prediction are discussed. Scale Prediction and the Concept of Saturation A majority of the indices used routinely by water treatment chemists are derived from the basic concept of saturation. A water is said to be saturated with a compound (e.g.
    [Show full text]
  • Standard X-Ray Diffraction Powder Patterns NATIONAL BUREAU of STANDARDS
    NATIONAL INSTITUTE OF STANDARDS & TECHNOLOGY Research Information Center Gaithersburg, MD 20899 NATL INST OF STANDARDS & TECH R.I.C. A1 11 00988606 /NBS monograph QC100 .U556 V25-12;1975 C.1 NBS-PUB-C 19 NBS MONOGRAPH 25 " SECTION 12 U.S. DEPARTMENT OF COMMERCE / National Bureau of Standards Standard X-ray Diffraction Powder Patterns NATIONAL BUREAU OF STANDARDS 1 The National Bureau of Standards was established by an act of Congress March 3, 1901. The Bureau's overall goal is to strengthen and advance the Nation's science and technology and facilitate their effective application for public benefit. To this end, the Bureau conducts research and provides: (1) a basis for the Nation's physical measurement system, (2) scientific and technological services for industry and government, (3) a technical basis for equity in trade, and (4) technical services to promote public safety. The Bureau consists of the Institute for Basic Standards, the Institute for Materials Research, the Institute for Applied Technology, the Institute for Computer Sciences and Technology, and the Office for Information Programs. THE INSTITUTE FOR BASIC STANDARDS provides the central basis within the United States of a complete and consistent system of physical measurement; coordinates that system with measurement systems of other nations; and furnishes essential services leading to accurate and uniform physical measurements throughout the Nation's scientific community, industry, and commerce. The Institute consists of a Center for Radiation Research, an Office of Meas- urement Services and the following divisions: Applied Mathematics — Electricity — Mechanics — Heat — Optical Physics — Nuclear Sciences 2 — Applied Radiation 2 — Quantum Electronics 3 — Electromagnetics 3 — Time 3 3 3 and Frequency — Laboratory Astrophysics — Cryogenics .
    [Show full text]
  • Standard X-Ray Diffraction Powder Patterns
    NBS MONOGRAPH 25—SECTION 4 Standard X-ray Diffraction Powder Patterns U.S. DEPARTMENT OF COMMERCE NATIONAL BUREAU OF STANDARDS THE NATIONAL BUREAU OF STANDARDS The National Bureau of Standards is a principal focal point in the Federal Government for assuring maximum application of the physical and engineering sciences to the advancement of technology in industry and commerce. Its responsibilities include development and mainte- nance of the national standards of measurement, and the provisions of means for making measurements consistent with those standards; determination of physical constants and properties of materials; development of methods for testing materials, mechanisms, and structures, and making such tests as may be necessary, particularly for government agencies; cooperation in the establishment of standard practices for incorporation in codes and specifi- cations advisory service to government agencies on scientific and technical problems ; invention ; and development of devices to serve special needs of the Government; assistance to industry, business, and consumers m the development and acceptance of commercial standards and simplified trade practice recommendations; administration of programs in cooperation with United States business groups and standards organizations for the development of international standards of practice; and maintenance of a clearinghouse for the collection and dissemination of scientific, technical, and engineering information. The scope of the Bureau's activities is suggested in the following listing of its three Institutes and their organizatonal units. Institute for Basic Standards. Applied Mathematics. Electricity. Metrology. Mechanics. Heat. Atomic Physics. Physical Chemistry. Laboratory Astrophysics.* Radiation Phys- ics. Radio Standards Laboratory:* Radio Standards Physics; Radio Standards Engineering. Office of Standard Reference Data. Institute for Materials Research.
    [Show full text]
  • Evaluation of Field Sampling and Preservation Methods for Strontium-90 in Ground Water at the Idaho National Engineering Laboratory, Idaho
    EVALUATION OF FIELD SAMPLING AND PRESERVATION METHODS FOR STRONTIUM-90 IN GROUND WATER AT THE IDAHO NATIONAL ENGINEERING LABORATORY, IDAHO By L. DeWayne Cecil, LeRoy L. Knobel, and Steven J. Wegner U.S. Geological Survey and Linda L. Moore U.S. Department of Energy U.S. GEOLOGICAL SURVEY Water-Resources Investigations Report 89-4146 Prepared in cooperation with the U.S. DEPARTMENT OF ENERGY Idaho Falls, Idaho September 1989 DEPARTMENT OF THE INTERIOR MANUEL LUJAN, JR., Secretary U.S. GEOLOGICAL SURVEY Dallas L. Peck, Director For additional information Copies of this report can be write to: purchased from: Project Office U.S. Geological Survey U.S. Geological Survey INEL, MS 4148 Books and Open-File Reports Section P.O. Box 2230 Box 25425, Federal Center, Bldg. 810 Idaho Falls, ID 83403-2230 Denver, CO 80225 11 CONTENTS Page Abstract. .............................. 1 Introduction. ............................ 2 Purpose and scope. ....................... 4 Geohydrologic setting. ..................... 4 Previous investigations. .................... 6 Acknowledgments......................... 8 Sampling and preservation methods .................. 8 Analytical methods.......................... 9 Reporting of strontium-90 data. ................... 10 Quality assurance .......................... 12 Precision of analytical results ................... 12 Conclusions ............................. 14 References cited. .......................... 15 ILLUSTRATIONS Figure 1. Map showing location of the Idaho National Engineering Laboratory and selected facilities ...... 3 2. Map showing location of selected wells sampled for strontium-90 ..................... 5 TABLES Table 1.--Strontium-90 concentrations and associated analytical uncertainties in ground water from selected wells at the Idaho National Engineering Laboratory, Idaho. ..... 17 2.--Statistical comparison of strontium-90 concentrations and associated analytical uncertainties in acidified and unacidified samples of ground water from selected wells, Idaho National Engineering Laboratory, Idaho.
    [Show full text]
  • Chemistry of Strontium in Natural Water
    Chemistry of Strontium in Natural Water GEOLOGICAL SURVEY WATER-SUPPLY PAPER 1496 This water-supply paper was printed as separate chapters A-D UNITED STATES GOVERNMENT PRINTING OFFICE, WASHINGTON : 1963 UNITED STATES DEPARTMENT OF THE INTERIOR STEWART L. UDALL, Secretary GEOLOGICAL SURVEY Thomas B. Nolan, Director The U.S. Geological Survey Library has cataloged this publication as follows: U.S. Geological Survey. Chemistry of strontium in natural water. Washington, U.S. Govt. Print. Off., 1962. iii, 97 p. illus., diagrs., tables. 24 cm. (Its Water-supply paper 1496) Issued as separate chapters A-D. Includes bibliographies. 1. Strontium. 2. Water-Analysis. I. Title. (Series) CONTENTS [The letters in parentheses preceding the titles are those used to designate the separate chapters] Page (A) A survey of analytical methods for the determination of strontium in natural water, by C. Albert Horr____________________________ 1 (B) Copper-spark method for spectrochemical determination of strontirm in water, by Marvin W. Skougstad-______-_-_-_--_~__-___-_- 19 (C) Flame photometric determination of strontium in natural water, by C. Albert Horr_____._____._______________... 33 (D) Occurrence and distribution of strontium in natural water, by Margin W. Skougstad and C. Albert Horr____________.___-._-___-. 55 iii A Survey of Analytical Methods fc r The Determination of Strontium in Natural Water By C. ALBERT HORR CHEMISTRY OF STRONTIUM IN NATURAL rVATER GEOLOGICAL SURVEY WATER-SUPPLY PAPER 1496-A This report concerns work done on behalf of the U.S. Atomic Energy Commission and is published with the permission of the Commission UNITED STATES GOVERNMENT PRINTING OFFICE, WASHINGTON : 1959 UNITED STATES DEPARTMENT OF THE INTERIOR FRED A.
    [Show full text]
  • 2005 Minerals Yearbook Strontium
    2005 Minerals Yearbook STRONTIUM U.S. Department of the Interior July 2006 U.S. Geological Survey STRONTIUM By Joyce A. ober Domestic survey data and tables were prepared by Hoa P. Phamdang, statistical assistant, and the world production table was prepared by Regina R. Coleman, international data coordinator. Domestic strontium consumption decreased for the sixth sodium sulfide, sodium hydrosulfide, and strontium nitrate consecutive year because its major end use, color television businesses. Aligning the two companies’ operations in Germany, faceplate glass production, had declined dramatically in the India, the republic of Korea, and mexico allowed them to United States owing to the shift of production to Asia and compete more efficiently in the changing markets, especially in increased popularity of new flat panel television displays that do Asia (Solvay S.A., 2005). not use strontium carbonate in their glass. Worldwide, strontium ore production increased as a result of significantly expanded Consumption production in China and mexico. Strontium occurs commonly in nature; it averages 0.04% The uSGS estimated the distribution of strontium compounds of the Earth’s crust and is the 15th element in abundance by end use. of the six operations to which a survey request was (MacMillan and others, 1994). only two minerals, celestite sent, five responded. the information collected from this survey (strontium sulfate) and strontianite (strontium carbonate), and the information provided by the u.S. Census Bureau on however, contain strontium in sufficient quantities to make strontium trade were the bases for the end-use estimates listed in its recovery practical. of the two, celestite occurs much more table 2.
    [Show full text]
  • Excessive Sulfuric Acid Dosing Resulting in Irreversible Scale Formation
    Case Study: Excessive Sulfuric Acid Dosing Resulting in Irreversible Scale Formation M. Malki, American Water Chemicals, Inc. Abstract Many consultants in the RO water treatment industry recommend sulfuric acid dosing into the feed water as a safety measure. This case study reviews a situation where acid dosing was used with the intention of improving system performance but resulted in severe sulfate scaling. The difficulties in cleaning sulfate scales are discussed and after numerous lengthy trials, an effective cleaning procedure is found and implemented. Introduction: One of the “rules of thumb” recommended by most industry experts is the dosing of sulfuric acid into RO feed‐ water as a precautionary measure. Many caution to always dose enough acid to maintain a reduced pH. They argue that sulfuric acid will act as a back‐up scale inhibitor should the antiscalant dosing pump fail. While pH reduction provides excellent control for calcium carbonate and calcium phosphate scale formations, both are reversible scales that are among the easiest to clean. The advantages provided by sulfuric acid dosing have to be weighed against the risks of introducing excess sulfates into the feed water. Sulfates at high concentrations can combine with certain cations to form sparingly soluble salts at levels beyond their saturation limits. Sulfate scales are not pH dependent; they are formed by irreversible reactions which make them very difficult if not impossible to clean. Background When a recently commissioned RO plant in Southwest Florida could not achieve design permeate the head operator contacted the system manufacturer. The plant had been in operation for only 6 months.
    [Show full text]
  • Sulfate Removal from Injection Water in Oil Production
    LLenntechenntech info@[email protected] Tel.Tel. +31-152-610-900+31-152-610-900 www.lenntech.comwww.lenntech.com Fax. Fax. +31-152-616-289 +31-152-616-289 Sulfate Removal from Injection Water in Oil Production The DOW FILMTEC™ SR90 nanofiltration membrane (and the resultant sulfate removal technology) has been developed in a cooperative effort between The Dow Chemical Company and the Marathon Oil Company to selectively remove sulfate from seawater that is used for waterflood injection operations. There are two major advantages in the removal of sulfate from injected seawater. • Prevention of barium and strontium sulfate scale precipitation. When normal high sulfate seawater is injected into reservoirs which have formation water containing barium and strontium, mixing occurs forming a supersaturated barium and / or strontium sulfate solution. Upon pressure decreases in and around the production wells, the supersaturated barium and / or strontium sulfate solution is no longer stable and precipitation occurs. The result is scale formation in the production tubing and / or plugging of reservoir rock around the production well. Petroleum reserves are often lost. By removing sulfate from injected seawater, the potential for scaling is prevented. This is contrasted with traditional scale remediation treatments and procedures addressing scale problems after they occur. In deep water and other complex oil developments, sulfate removal, and the subsequent prevention of scale, provides significant cost advantages. • Souring Control / Mitigation in reservoirs. By removing the sulfate in the injected seawater, there simply is a reduced source of sulfur that can be converted to hydrogen sulfide by thermophilic sulfate reducing bacteria. Consequently, the risk of well souring is reduced.
    [Show full text]
  • A Novel Low-Temperature Non-Corrosive Sulfate/Sulfide
    sustainability Article A Novel Low-Temperature Non-Corrosive Sulfate/Sulfide Scale Dissolver Hany Gamal 1 , Salaheldin Elkatatny *,1 , Dhafer Al Shehri 1 and Mohamed Bahgat 2 1 College of Petroleum Engineering & Geosciences, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia; [email protected] (H.G.); [email protected] (D.A.S.) 2 Rosewell Energy, 327 El-Horreya Road, Cleopatra, Alexandria 21500, Egypt; [email protected] * Correspondence: [email protected]; Tel.: +966-594-663-692 Received: 4 February 2020; Accepted: 15 March 2020; Published: 20 March 2020 Abstract: The oil and gas production operations suffer from scale depositions. The scale precipitations have a damaging impact on the reservoir pores, perforations, downhole and completion equipment, pipeline network, wellhead chokes, and surface facilities. Hydrocarbon production possibly decreased because of the scale accumulation in the well tubular, leading to a well plugging, this requires wells to be shut-in in severe cases to perform a clean-out job. Therefore, scale deposition is badly affecting petroleum economics. This research aims to design a scale dissolver with low cost, non-damaging for the well equipment and has a high performance at the field operating conditions. This paper presents a novel non-corrosive dissolver for sulfate and sulfide composite scale in alkaline pH and works at low-temperature conditions. The scale samples were collected from a production platform from different locations. A complete description of the scale samples was performed as X-ray diffraction (XRD) and X-ray fluorescence (XRF). The new scale dissolver was prepared in different concentrations to examine its dissolution efficiency for the scale with time at low temperatures.
    [Show full text]
  • Foulants and Cleaning Procedures for Composite Polyamide RO Membrane Elements (ESPA, ESNA, CPA, LFC, NANO and SWC)
    TSB107.21 Page 1 Lenntech [email protected] www.lenntech.com Tel. +31-15-261.09.00 Fax. +31-15-261.62.89 Technical Service Bulletin October 2011 TSB107.21 Foulants and Cleaning Procedures for composite polyamide RO Membrane Elements (ESPA, ESNA, CPA, LFC, NANO and SWC) This bulletin provides general information about the usual foulants affecting the performance of Hydranautics' Composite Polyamide Reverse Osmosis (RO) membrane elements and the removal of these foulants. The information in this bulletin applies to 4-inch, 6-inch, 8-inch, 8.5-inch, and 16-inch diameter RO membrane elements. Note: The Composite Polyamide type of RO membrane elements may not be exposed to chlorinated water under any circumstances. Any such exposure will cause irreparable damage to the membrane. Absolute care must be taken following any disinfection of piping or equipment or the preparation of cleaning or storage solutions to ensure that no trace of chlorine is present in the feedwater to the RO membrane elements. If there is any doubt about the presence of chlorine, perform chemical testing to make sure. Neutralize any chlorine residual with a sodium bisulfite solution, and ensure adequate mixing and contact time to accomplish complete dechlorination. Dosing rate is 1.8 to 3.0 ppm sodium bisulfite per 1.0 ppm of free chlorine. Note: It is recommended that all RO membrane cleaning operations should be closely coordinated with Hydranautics during the RO membrane element warranty period. Hydranautics field service personnel are available to be on site for cleaning assistance, should the need arise. Please contact Hydranautics for current charges for this service.
    [Show full text]
  • Solubility and Enthalpy of the Barium-Strontium Sulfate Solid
    Circular 116 1971 SOLUBILITY AND ENTHALPY OF THE BARIUM- STRONTIUM SULFATE SOLID SOLUTION SERIES NEW MEXICO STATE BUREAU OF MINES AND MINERAL RESOURCES NEW MEXICO BUREAU OF MINES AND MINERAL RESOURCES Don H. Baker, Jr., Director Full-Time Staff JOYCE M. AGUILAR, Stenographer FRANK E. KOTLOWSKI, Ass't. Dir. & Sr. Geol. WILLIAM E. ARNOLD, Scientific Illustrator JUDITH M. PERALTA, Clerk-Typist, Stenog. BLAIR R. BENNER, Junior Metallurgist ROBERT L. PRICE, Draftsman ROBERT A. BIEBERMAN, Petroleum Geologist JACQUES R. RENAULT, Geologist LYNN A. BRANDVOLD, Chemist RONALD ROMAN, Chief Research Metallurgist CHARLES E. CHAPIN, Geologist JOHN W. SHOMAKER, Geologist RICHARD R. CHAVEZ, Technician JACKIE H. SMITH, Laboratory Assistant JILL COLLIS, Secretary KARL VONDER LINDEN, Min. Eng., Env. Geol. Lois M. DEVLIN, Office Manager CHARLES W. WALKER, Mineralogist JO DRAKE, Administrative Ass't. & Sec'y. ROBERT H. WEBER, Senior Geologist ROUSSEAU H. FLOWER, Senior Paleontologist MAX E. WILLARD, Economic Geologist ROY W. FOSTER, Petroleum Geologist JUARINE W. WOOLDRIDGE, Editorial Clerk WILLIAM L. HAWKS, Materials Engineer MICHAEL W. WOOLDRIDGE, Draftsman ROBERT W. KELLEY, Editor & Geologist Part-Time Staff ROSHAN B. BHAPPU, Senior Metallurgist ROBIN C. LEASE, Geologist JAMES A. BRIERLEY, Ass't. Prof. Biology RUFIE MONTOYA, Dup. Mach. Oper. E. JACK COATS, Editorial Clerk JOHN REICHE, Instrument Manager ROLAND F. DICKEY, Public Relations Graduate Students UMAR M. UDDIN AHMAD, Metallurgist MICHAEL JAWORSKI, Geologist ROGER ALLMENDINGER, Geologist HENRY HANS KOEHN, Geologist RENA MAE BONEM, Paleontologist MARSHA KOEHN, Geologist CORALE BRLERLEY, Chemist HAIA ROFFMAN, Geochemist JIM BRUNING, Geologist WILLIAM WILKINSON, Geologist Plus more than 28 undergraduate assistants New Mexico Tech Staff Advisors GALE BILLINGS, Geoscience W.
    [Show full text]
  • Material Safety Data Sheet Strontium Sulfate MSDS
    He a lt h 1 0 Fire 0 1 0 Re a c t iv it y 0 Pe rs o n a l Pro t e c t io n E Material Safety Data Sheet Strontium Sulfate MSDS Section 1: Chemical Product and Company Identification Product Name: Strontium Sulfate Contact Information: Catalog Codes: SLS2047 Sciencelab.com, Inc. 14025 Smith Rd. CAS#: 7759-02-6 Houston, Texas 77396 RTECS: Not available. US Sales: 1-800-901-7247 International Sales: 1-281-441-4400 TSCA: TSCA 8(b) inventory: Strontium Sulfate Order Online: ScienceLab.com CI#: Not available. CHEMTREC (24HR Emergency Telephone), call: Synonym: 1-800-424-9300 Chemical Name: Strontium Sulfate International CHEMTREC, call: 1-703-527-3887 Chemical Formula: SrSO4 For non-emergency assistance, call: 1-281-441-4400 Section 2: Composition and Information on Ingredients Composition: Name CAS # % by Weight Strontium Sulfate 7759-02-6 100 Toxicological Data on Ingredients: Not applicable. Section 3: Hazards Identification Potential Acute Health Effects: Slightly hazardous in case of skin contact (irritant), of eye contact (irritant), of ingestion, of inhalation. Potential Chronic Health Effects: CARCINOGENIC EFFECTS: Not available. MUTAGENIC EFFECTS: Not available. TERATOGENIC EFFECTS: Not available. DEVELOPMENTAL TOXICITY: Not available. Repeated or prolonged exposure is not known to aggravate medical condition. Section 4: First Aid Measures Eye Contact: Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Cold water may be used. WARM water MUST be used. Get medical attention if irritation occurs. Skin Contact: Wash with soap and water.
    [Show full text]