General Reprocessing Instructions for KARL STORZ Products (USA)

Total Page:16

File Type:pdf, Size:1020Kb

General Reprocessing Instructions for KARL STORZ Products (USA) General Reprocessing Instructions for KARL STORZ Products (USA) Important information for users of KARL STORZ instruments Please read this entire instructions-for-use carefully before using the KARL STORZ instruments. Failure to follow the instructions, cautions and warnings presented in this manual may result in serious consequences to the patient. Procedures for proper handling and care of KARL STORZ instruments are described in this instructions-for-use. KARL STORZ endoscopes and accessories are delicate surgical instruments and should be handled with care. Improper use during surgical procedures will result in damage, breakage or patient injury. KARL STORZ Endoscopy-America, Inc. assumes no liability if the instruments are misused, mishandled or otherwise abused. Proper handling and care, as described in this instructions-for-use, will prolong the life of these instruments Contents Important Information 1 Why is Water Quality Important? Water quality requirements 2 Table 1 – General Sterilization and High Level Disinfection Matrix 3 Table 2 – Camera Heads Sterilization and High Level Disinfection Matrix 4 Pre-Cleaning Preparation 5 Cleaning Instructions for Instruments 5 - 7 Table 3 – Cleaning brushes 6 Sterilization Instructions (general introduction) 7 Ethylene oxide (EtO) Sterilization 8 - 9 Table 4 – EtO Cycle Parameters 9 Steam 10 - 11 STERRAD Sterilization Systems 12 - 15 Table 5 – STERRAD Sterilization Systems Lumen Claims 15 Table 6 – STERRAD Tray Compatibility and Maximum Load Matrix 16 STERIS Amsco V-PRO Sterilization Systems 17 High Level Disinfection 18 - 20 Note: This document is updated frequently. Please check for latest update. KARL STORZ 2151 E. Grand Avenue Phone 424 218 8100 Endoscopy-America, Inc. El Segundo, CA 90245-5071 Toll Free 800 421 0837 PI-000035-20.1 2-03-11 General Reprocessing Instructions for KARL STORZ Products (USA) WHY IS WATER QUALITY IMPORTANT? The quality of water used for instrument processing has a considerable influence on the proper function and longevity of an instrument. A hard layer (lime deposits, scale) can form on instruments depending on water hardness and temperature that can be very difficult to dissolve. Excessive concentrations of chlorides can also cause pitting. Cleaning solutions made up with tap water will leave mineral residues on instruments that will not wash off fully even with de- ionized water. Over time, these residues will build and could affect instrument function. The quality of the final rinsing water is a part of the hygienic standards for reprocessing of medical devices. Rinsing water for final manual cleaning and disinfection of medical devices without following sterilization has to be absolutely free of pathogenic microorganisms. When an instrument is rinsed in tap water recontamination can occur. To recap: Water quality impacts on the following: 1. Medical Devices – Damage: pitting and corrosion with eventual loss of device function Reduction in cleaning efficacy Interference with high level disinfection/sterilization efficacy 2. Patient – Infection transmission Adverse reaction such as inflammation and fever General characteristics to be considered for reprocessing medical device: 1. Microbiological content of the water 2. Inorganic and organic content of the water Distilled or demineralized water is recommended for cleaning and rinsing of all instruments. PI-000035-20.1 2-03-11 2 General Reprocessing Instructions for KARL STORZ Products (USA) Table 1 STERILIZATION High Level Disinfection STERRAD STERIS Automated Manual Products ) 2 O * REFER TO REPROCESSING SECTIONS 2 Steam FOR DETAILED INSTRUCTIONS NX 100S 100NX (2.0% H STERIS Cidex OPA Cidex 14 Day Reliance EPS Amsco V-PRO Ethylene oxide gas gas oxide Ethylene Refer to page number listed in matrix box Resert XL HLD * Medivators AER 1 Hopkins Telescopes A X X X X X X 2 Hopkins Telescopes with Instrument Channels A X 15* X X X X 3 Semi Rigid Telescopes A X X X X X X 4 Semi Rigid Telescopes with Instrument channels A X 14* 13* X X 5 Bonfils Intubation scopes including DCI (no channel) X X X X X X C-MAC 8401AX/BX/HX/AXC/BXC/KXC 6 X X X X X X X Intubation Laryngoscopes V-MAC 8401A/B/C/D/E/G Intubation Laryngoscopes 7 X X X# X X* # Blade only 8 LED Bright Blades A X X X X X X 9 Flexible Fiberscopes X X X X X X X 10 Flexible Fiberscopes w/ no channels, ureteral stents X X X X X X X X 11 Flexible Video Endoscopes X X X 12 Flexible Video Endoscopes w/ no channels X X X X 13 Insulated/Non-insulated one piece surgical instruments X X X X X X X CLICKline (insulated) or CLICKline (non-insulated) + 14 X X Take-Apart Instruments (insulated) disassembled 15 Trocars/Cannulas/Sheaths/Obturators/Laryngoscopes X X 15* 15* 15* X X 16 Fiber optic light cables X X X X X X X 17 Cameras (See Table 2, page 4) A X X 4* 4* 4* X X 18 Powered instruments 10* X 19 Resectoscope Working Element X X 18* 18* 20 High Frequency cords A X X X X 21 Bronchoscope/Esophagoscope Tubes (light carrier off) X X X X 21 Light Carriers A X X X X X X 22 Direct Laryngoscope Handles (light carrier removed) X X X X 23 Bronchoscope/Laryngoscope Suction Tubes X X X X 24 Prismatic Light Deflectors A X X X X X X 25 Metal instrument + Lubricant + Flexible Forceps X X Approved method A: Telescopes, Prismatic Light Deflectors, and Cameras marked “AUTOCLAV” may be steam sterilized in pre-vacuum only, NO Flash. PI-000035-20.1 2-03-11 3 General Reprocessing Instructions for KARL STORZ Products (USA) Table 2 HIGH LEVEL STERILIZATION DISINFECTION STERRAD STERIS (Vaporized H2O2, Plasma) Sterile CAMERA HEADS EtO CIDEX Resert XL Gas 100S 100S NX 100NX Amsco (Glutaraldehyde, HLD Drape 2.4%) (US) “Short” “Standard” “Standard” V-PRO 1 / (2.0% H2O2) Cycle Cycle Cycle V-PRO 1 Plus (Vaporized H O ) (Int’l) 2 2 Non-Autoclavable H3-Z (with blue cable nut) H3-ZI (with blue cable nut) H3-P (with blue cable nut) H3 (with blue cable nut) H3 (with black cable nut) S3 / S1 (with blue cable cylindrical ring) S3 / S1 P3 / P1 F3 D1 Telecam DCI-1/DCI-2 Tricam Autoclavable A3 /A1 H3-ZA H3-FA Telecam A/C Tricam A/C = Approved method Note: Non-soakable Cameras (22220154-3 - H3-M HD Microscope Head) Surface Disinfection Only H3-Z S3 / S1 H3 H3-ZA Red cable back nut Blue cable back nut Blue cable cylindrical slide ring Red Cable Nut (H3-FA, H3-ZA) Camera heads are Autoclavable. Blue Cable Back Nut (H3/H3Z HD Cameras) or Cylindrical Slide Ring (S3/S1 SD Cameras) indicates validation for STERRAD NX/100NX and/or STERIS Amsco V-PRO Vapor Hydrogen Peroxide Sterilizers. PI-000035-20.1 2-03-11 4 General Reprocessing Instructions for KARL STORZ Products (USA) WARNING: KARL STORZ instruments should be thoroughly cleaned and high level disinfected or sterilized according to validated infection control procedures prior to use and subsequent reuse. CAUTION: Any deviations from the recommended parameters for cleaning and sterilization should be validated by the user. Pre-Cleaning Preparation: Place the instruments in containers and soak no longer than one hour with a neutral pH (pH 6.0 to 8.0) enzymatic cleaning solution (e.g., Enzol, Metrizyme, or equivalent, diluted to proper concentration per manufacturer’s instructions) immediately after use to prevent blood, protein, and other contaminants from drying onto the instruments. Wipe the instruments thoroughly with a lint-free, disposable cloth, preferably moistened with an enzymatic cleaning solution. CAUTION: DO NOT soak the telescope in any solution (including water) for longer than 60 minutes. CAUTION: DO NOT use alcohol for wipe-down of the flexible endoscope shaft. DO NOT use pushing and pulling movements to avoid damage. Water Quality Requirements: Distilled or demineralized water is recommended for cleaning and rinsing of all instruments. Cleaning Instructions for Instruments: CAUTION: WEAR PROTECTIVE GLOVES, CLOTHING, AND A FACE MASK FOR CLEANING OF CONTAMINATED INSTRUMENTS. Caution: Do not process sheaths with ceramic beaks or optical devices such as flexible endoscopes, telescopes, cameras, and light cables in an ultrasonicator. Caution: Do not soak or immerse in a liquid/chemical solution for the following instruments: Telescopes with HAMOU eyepiece drive mechanism Magnifying lenses with drive mechanism IMPERATOR handpieces Caution: Remove pressure compensation cap from flexible endoscopes before cleaning. 1. All instruments with removable parts should be disassembled. All moving parts should be in the open position. 2. Thoroughly rinse the instruments to remove all gross debris prior to cleaning. 3. Manual cleaning is recommended. Instruments (except the aforementioned devices) with difficult to reach areas such as joints, lumens and stopcocks can be processed using an ultrasonicator. It is important to follow the manufacturer’s instructions for operating the ultrasonicator. 4. Completely immerse the instruments, with instrument jaws open, in a neutral pH enzymatic cleaning solution (e.g. Enzol, Metrizyme or equivalent diluted to proper concentration per manufacturer’s instructions). Use distilled or demineralized water to prepare cleaning solution PI-000035-20.1 2-03-11 5 General Reprocessing Instructions for KARL STORZ Products (USA) to proper concentration. KARL STORZ does not recommend the use of detergents alone, as they contain high concentrations of surfactants, which can leave a film on the instruments. 5. Remove any residual blood, protein material and contaminants from the
Recommended publications
  • THE BONFILS INTUBATION ENDOSCOPE in Clinical and Emergency Medicine
    ® THE BONFILS INTUBATION ENDOSCOPE in Clinical and Emergency Medicine Tim PIEPHO Rüdiger NOPPENS ® THE BONFILS INTUBATION ENDOSCOPE in Clinical and Emergency Medicine Tim PIEPHO Rüdiger NOPPENS Department of Anesthesiology University Medical Center of the Johannes Gutenberg University Mainz, Germany With contributions from: Andreas THIERBACH Rita METZ Pedro BARGON 4 The BONFILS Intubation Endoscope in Clinical and Emergency Medicine Important notes: The BONFILS Intubation Endoscope Medical knowledge is ever changing. As new research in Clinical and Emergency Medicine and clinical experience broaden our knowledge, Tim Piepho and Rüdiger Noppens changes in treat ment and therapy may be required. Department of Anesthesiology, The authors and editors of the material herein have University Medical Center of the Johannes Gutenberg University Mainz, Germany consulted sources believed to be reliable in their efforts to provide information that is complete and in accord with the standards accept ed at the time of publication. However, in view of the possibili ty of human error by Correspondence address: the authors, editors, or publisher, or changes in medical Tim Piepho knowledge, neither the authors, editors, publisher, nor Klinik für Anästhesiologie any other party who has been involved in the preparation Universitätsmedizin der Johannes Gutenberg-Universität Mainz of this booklet, warrants that the information contained Langenbeckstr. 1 herein is in every respect accurate or complete, and they Telephone: +49 (0)6131/171 are not responsible for any errors or omissions or for the results obtained from use of such information. The E-mail: [email protected] information contained within this booklet is intended for use by doctors and other health care professionals.
    [Show full text]
  • Olympus Uptime Guarantee
    Olympus Uptime Guarantee At Olympus, we strive to provide our customers with products and services that help optimize equipment use – and our repair agreements are no exception. The Olympus Uptime Guarantee (OUG) is a no-cost enhancement to our comprehensive Full Service Agreement. It is designed to curb delays caused by out-of-service equipment, enabling you to maximize procedural uptime. OUG delivers unprecedented benefits to eligible* Full Service Agreement customers, including: Next-Day Replacement Guaranteed Service Expense Control OUG provides no hassle, If we are unable to provide Full Service Agreements next-day replacement for next-day replacement, already provide accidental surgical products in need Olympus will cover half of damage coverage and fixed of repair through our refurbishment-level charges monthly repair expenditures. Advanced Replace® upon inspection of the With OUG, your Full Service Program – guaranteed. out-of-service product. Agreement will reflect the specific repair required for your out-of-service product, rather than a pre-fixed charge. *Eligibility Requirements: Product must be listed on current Olympus Uptime Guarantee product list, and Product must be covered on a Full Service Agreement with a start date of 01/01/15 or later. Olympus Uptime Guarantee Follow Four Steps to Receive the Olympus Uptime Guarantee: 1. Call 1-800-848-9024 by 8PM EST, Monday – Friday, to request an Advanced Replacement. 2. Provide contact information, model, serial number, and other requested information to a Customer Solutions Representative. OUG eligibility will be confirmed. 3. Receive Advanced Replacement shipping confirmation and an RMA for your out-of-service product. 4. Upon receipt of Advanced Replacement, immediately send out-of-service product to Olympus.
    [Show full text]
  • Optical Devices in Tracheal Intubation—State of the Art in 2020
    diagnostics Review Optical Devices in Tracheal Intubation—State of the Art in 2020 Jan Matek 1,2, Frantisek Kolek 3, Olga Klementova 4, Pavel Michalek 5,6 and Tomas Vymazal 3,* 1 1st Department of Surgery—Department of Abdominal, Thoracic Surgery and Traumatology, First Faculty of Medicine, Charles University in Prague and General University Hospital in Prague, 12800 Prague, Czech Republic; [email protected] 2 Medical Faculty, Masaryk University, 62500 Brno, Czech Republic 3 Department of Anesthesiology and Intensive Medicine, University Hospital Motol, V Úvalu 84, 15000 Praha, Czech Republic; [email protected] 4 Department of Anesthesiology and Intensive Medicine, University Hospital Olomouc, I.P. Pavlova 185, Nová Ulice, 77900 Olomouc, Czech Republic; [email protected] 5 Department of Anesthesiology and Intensive Medicine, First Faculty of Medicine, Charles University in Prague and General University Hospital, U Nemocnice 499/2, 12808 Praha, Czech Republic; [email protected] 6 Department of Anaesthesia, Antrim Area Hospital, Antrim BT41 2RL, UK * Correspondence: [email protected]; Tel.: +420-606-413-489 Abstract: The review article is focused on developments in optical devices, other than laryngoscopes, in airway management and tracheal intubation. It brings information on advantages and limita- tions in their use, compares different devices, and summarizes benefits in various clinical settings. Supraglottic airway devices may be used as a conduit for fiberscope-guided tracheal intubation mainly as a rescue plan in the scenario of difficult or failed laryngoscopy. Some of these devices offer the possibility of direct endotracheal tube placement. Hybrid devices combine the features of two different intubating tools.
    [Show full text]
  • Diagnostic and Therapeutic Push Type Enteroscopy in Clinical Use Gut: First Published As 10.1136/Gut.37.3.346 on 1 September 1995
    346 Gut 1995; 37: 346-352 Diagnostic and therapeutic push type enteroscopy in clinical use Gut: first published as 10.1136/gut.37.3.346 on 1 September 1995. Downloaded from G R Davies, M J Benson, D J Gertner, R M N Van Someren, D S Rampton, C P Swain Abstract laser or bipolar diathermy. In conclusion, This study describes small bowel push push enteroscopy is a practical and enteroscopy in routine clinical practice, valuable clinical service, which should using a purpose designed instrument probably become available on a sub- (Olympus SIF-10). Fifty six patients had a regional basis. total of60 procedures over a two and a half (Gut 1995; 37: 346-352) year period. The median (range) depth of Keywords: enteroscopy, small intestine, small intestine intubated was 45 (15-90) gastrointestinal bleeding, enteral nutrition. cm. Procedure time varied from 10-45 minutes. Most enteroscopies were performed during routine gastroscopy lists. The technique was comparatively In life the small bowel is roughly three metres easy for experienced endoscopists to in length: at necropsy (and during entero- learn. Forty two procedures were for diag- scopy) the organ may be stretched by nostic purposes. Eleven patients had 200-300%.1 Mobile and tortuously folded gastrointestinal bleeding where the source in the peritoneal cavity, it is little surprise was obscure, or where early investigations that endoscopy of this organ is technically had suggested a small bowel source: a challenging. Ten years after the first descrip- specific diagnosis was made in 450/0 of tions of non-operative enteroscopy2 it is these cases.
    [Show full text]
  • Multi-Use USB Video Scope Veterinary Diagnostic Kit
    Multi-Use USB Video Scope Veterinary Diagnostic Kit High class technology at an affordable price The new Multi-Use Diagnostic Endoscope can be used as a high-resolution otoscope, using the removable otoscopic sheath with 2mm working channel. Through the use of interchangeable diagnostic cannula, this endoscope can do multiple procedures in your practice, such as rhinoscopy, arthroscopy or laparoscopy. With the included color camera and USB Video adaptor, real-time visualization on your computer is now both possible and affordable. 105cm x 2.7mm, 0 or 30 degree scope Oto-sheath with 2mm channel Diagnostic cannula with stopcock Operating sheath with dual stopcock System includes: Endoscope with otoscopy sheath Diagnostic cannula Operating sheath Flexible foreign body forceps 150W lightsource Optional Analog / USB video camera for real-time PC screen visualisation or still image capture ! Veterinary Video Otoscope Complete System Advanced patient care & added value for your practice The Video Otoscope System is an affordable video otoscopy solution for your practice. The optical probe comes with an otoscopy sheath with a 2mm working channel that can be used for taking a biopsy, retrieving a foreign body or flushing the ear canal. This system allows the user to accomplish many procedures that would normally be impossible with an ordinary otoscope. Optical Probe with Otoscopy Sheath 150W Lightsource CCD High Resolution Color Camera Flexible Micro-Fiberscope Veterinary Endoscopy Kit THIS IS THE SMALLEST FLEXIBLE SCOPE
    [Show full text]
  • Olympus Uptime Guarantee
    Olympus Uptime Guarantee At Olympus, we strive to provide our customers with products and services that help optimize equipment use – and our repair agreements are no exception. The Olympus Uptime Guarantee (OUG) is a no-cost enhancement to our comprehensive Full Service Agreement. It is designed to curb delays caused by out-of-service equipment, enabling you to maximize procedural uptime. OUG delivers unprecedented benefits to eligible* Full Service Agreement customers, including: Next-Day Replacement Guaranteed Service Expense Control OUG provides no hassle, next-day If we are unable to provide Full Service Agreements already replacement for surgical products in next-day replacement, Olympus provide accidental damage coverage need of repair through our Advanced will cover half of refurbishment and fixed monthly repair expenditures. Replace® Program – guaranteed. level charges upon inspection of With OUG, your Full Service Agreement the out-of-service product. will reflect the specific repair required for your out-of-service product, rather than a pre-fixed charge. *Eligibility Requirements: Product must be listed on current Olympus Uptime Guarantee product list, and Product must be covered on a Full Service Agreement with a start date of 01/01/15 or later. Olympus Uptime Guarantee Follow Four Steps to Receive the Olympus Uptime Guarantee: 1. Call 1-800-848-9024 by 8PM EST, Monday – Friday, to request an Advanced Replacement (ARP). 2. Provide contact information, model, serial number, and other requested information to a Customer Solutions Representative. OUG eligibility will be confirmed. 3. Receive ARP shipping confirmation and an RMA for your out-of-service product. 4. Upon receipt of Advanced Replacement, immediately send out-of-service product to Olympus.
    [Show full text]
  • Endoscopes for Anesthesiology and Emergency Medicine
    ENDOSCOPES FOR ANESTHESIOLOGY AND EMERGENCY MEDICINE 5th EDITION 2/2012 US Chapter Pages 1 BASIC SETS AN-SET 1-10 AN-LA, AN-GR, LARYNGOSCOPE BLADES 11-30 2 AN-LA-ACC AN-DAM, AN-DAM-V, VIDEO INTUBATION SYSTEMS 31-98 3 AN-DAM-F, AN-DAM-ACC BRONCHOSCOPES AND TRACHEOSCOPES AN-BRO 99-116 4 FOR FOREIGN BODY REMOVAL 5 INSTRUMENT CARTS AN-VC 117-124 6 COMPONENTS, SPARE PARTS AN-SP SP 1-16 KARL STORZ OR1 NEO™, TELEPRESENCE 7 HYGIENE, ENDOPROTECT1 ENDOSCOPES FOR ANESTHESIOLOGY AND EMERGENCY MEDICINE 5th EDITION 2/2012 US Important information for U.S. customers Note: Certain devices and references made herein to specific indications of use may have not received clearance or approval by the United States Food and Drug Administration. Practitioners in the United States should first consult with their local KARL STORZ representative in order to ascertain product availability and specific labe- ling claims. Federal (USA) law restricts certain devices referenced herein to sale, distribution, and use by, or on the order of a physician, dentist, veterinarian, or other practitioner licensed by the law of the State in which she/he practices to use or order the use of the device. Important Notes: Endoscopes and accessories contained in this catalog have been designed in part with the cooperation of physici- ans and are manufactured by the KARL STORZ group. If subcontractors are hired to manufacture individual com- ponents, these are made according to proprietary KARL STORZ plans or drawings. Furthermore, these products are subject to strict quality and control guidelines of the KARL STORZ group.
    [Show full text]
  • Fiberoptic Intubation: an Overview and Update
    Fiberoptic Intubation: An Overview and Update Stephen R Collins MD and Randal S Blank MD PhD Introduction Fiberoptic Technology Indications Fiberoptic Techniques Patient Position and General Techniques Patient Preparation Regional Anesthesia Sedation Versus General Anesthesia Combined Techniques Outcomes/Comparison Studies Complications Training Surveys United States Training Cadavers Virtual Simulation and Model Fidelity Additional Uses Summary Fiberoptic intubation (FOI) is an effective technique for establishing airway access in patients with both anticipated and unanticipated difficult airways. First described in the late 1960s, this approach can facilitate airway management in a variety of clinical scenarios given proper patient preparation and technique. This paper seeks to review the pertinent technology, clinical techniques, and indi- cations for and complications of its use. The role of FOI in airway management algorithms is discussed. Evidence is presented comparing FOI to other techniques with regard to difficult airway management. In addition, we have reviewed the literature on training processes and skill develop- ment in FOI. Key words: fiberoptic bronchoscope (FOB); fiberoptic intubation (FOI); fiberoptic laryn- goscopy; difficult airway; awake intubation. [Respir Care 2014;59(6):865–880. © 2014 Daedalus Enter- prises] Introduction cade later, an English anesthetist named Peter Murphy used a fiberoptic choledocoscope to aid in the nasal intu- The transmission of a visual image through a flexible fiberoptic bundle was first reported in 1954.1 Over a de- The authors have disclosed no conflicts of interest. The authors are affiliated with the Department of Anesthesiology, Uni- versity of Virginia, Charlottesville, Virginia. Correspondence: Stephen R Collins MD, Department of Anesthesiology, University of Virginia, PO Box 800710, Charlottesville, VA 22908.
    [Show full text]
  • The Olympus Medical Business: Profile and Perspectives, 1950-Present
    The Olympus Medical Business The Olympus Medical Business: Profile and Perspectives, 1950-Present The Olympus Medical Business Date of issuance : October 2017. Edit : Olympus Corporation PR/IR Department Introduction Olympus developed the world’s first practical gastrocamera in 1950. This innovative device contributed greatly in establishing methods for the early diagnosis of stomach cancer, a kind of cancer that had previously been a leading cause of death in Japan. Since then, Olympus has strived to make further developments with the use of endoscopes for various forms of examination and treatment. Advancements in “minimally invasive therapy” are continuously being made within the field of medicine. Surgeries that in the past were operated by opening the abdomen can now be performed using an endoscope inserted through a small incision, in most cases leaving minimal scarring only. As a result, the patient’s pain and suffering is reduced and quality of life (QOL) is significantly improved. By publishing “The Olympus Medical Business” we hope to provide our investors, shareholders and the public with a general understanding of the medical business of Olympus. We will also introduce recent trends in endoscopic diagnosis and treatment. Olympus Group Corporate Philosophy Olympus PR/IR Department CONTENTS Medical Business of Olympus 02−05 Latest Medical Devices 06−11 Strengths of Olympus Medical Business 12−15 Gastrointestinal Endoscopes The Olympus Group strives to realize better health and happiness for Special Interview : Further Progress in Endoscopic Medicine 16−18 people by being integral members of society, sharing common values, Engineer Interview : Early Diagnosis Made Possible by Endoscope 19−21 and proposing new values through its business activities.
    [Show full text]
  • The Olympus Medical Business: Profile and Perspectives, 1950-Present
    The Olympus Medical Business The Olympus Medical Business: Profile and Perspectives, 1950-Present The Olympus Medical Business Date of issuance : October 2017. Edit : Olympus Corporation PR/IR Department Olympus Group Corporate Philosophy The Olympus Group strives to realize better health and happiness for people by being integral members of society, sharing common values, and proposing new values through its business activities. Introduction Olympus developed the world’s first practical gastrocamera in 1950. This innovative device contributed greatly in establishing methods for the early diagnosis of stomach cancer, a kind of cancer that had previously been a leading cause of death in Japan. Since then, Olympus has strived to make further developments with the use of endoscopes for various forms of examination and treatment. Advancements in “minimally invasive therapy” are continuously being made within the field of medicine. Surgeries that in the past were operated by opening the abdomen can now be performed using an endoscope inserted through a small incision, in most cases leaving minimal scarring only. As a result, the patient’s pain and suffering is reduced and quality of life (QOL) is significantly improved. By publishing “The Olympus Medical Business” we hope to provide our investors, shareholders and the public with a general understanding of the medical business of Olympus. We will also introduce recent trends in endoscopic diagnosis and treatment. Olympus PR/IR Department CONTENTS Medical Business of Olympus 02−05 Latest Medical
    [Show full text]
  • Advanced Replace® Program Minimize Downtime
    Advanced Replace® Program Minimize downtime. Maximize uptime. When you choose to use the Olympus Advanced Replace program, we’ll send you a replacement endoscope that meets Olympus manufacturer specifications and functions at peak performance. ENDOEYE FLEX Olympus parts. Olympus expertise. Achieve maximum uptime. Keeping your Olympus endoscope functioning at peak performance is a job for Olympus experts. Our factory-trained Emergencies are difficult to predict. That’s why Olympus has technicians ensure that your endoscope is not altered in any ® developed the Advanced Replace Program, so you won’t way. We’re the only service and replacement provider that have to reschedule or cancel procedures. When you request uses manufacturer-approved parts, materials, and repair a replacement endoscope by 8:00pm EST Monday through protocols – all critical to maintaining the authentic Olympus Saturday, you’ll receive it by 10:00am the next business day. feel and performance. Secure your investment. The most cost-effective way to keep your Olympus endoscopes performing like new is to service them by the manufacturer. We’ll fix it right the first time – keeping your repairs to a minimum, maximizing uptime, and increasing productivity. No one does more to protect your investment and secure your bottom line. URF-P6 For further information, contact your Olympus is a registered trademark of Olympus Corporation, Olympus America Inc., and/or their affiliates. I Medical devices listed may not be available for sale in all countries. Olympus Territory Manager. For immediate For more information, contact your Olympus assistance, call 800-537-5739. sales representative, or call 800-537-5739.
    [Show full text]
  • Veterinary Endoscopy – Small Animals –
    VETERINARY ENDOSCOPY – SMALL ANIMALS – 4th EDITION 2/2012 Chapter Pages 1 OTOSCOPY AND RHINOSCOPY VET-S-RH 1-10 BRONCHOSCOPY AND GASTROSCOPY, VET-S-BRO 11-18 2 RIGID INSTRUMENT SETS FLEXIBLE ENDOSCOPES FOR VET-S-BRO-FIB 19-28 3 RESPIRATORY AND URINARY TRACTS VET-S-VE-GE, VIDEO GASTROSCOPES 29-46 4 VET-S-VE-ACC VET-S-LAP-TEL, VET-S-LAP-TROC-INTRO, LAPAROSCOPES AND ACCESSORIES 47-88 5 VET-S-LAP-TROC, VET-S-LAP-INST, VET-S-LAP-NH, VET-S-LAP-SET HANDLES AND INSTRUMENTS VET-S-LAP 89-92 6 FOR SUCTION AND IRRIGATION VET-S-ART, ARTHROSCOPES AND ACCESSORIES 93-118 7 VET-S-ART-INST 8 CYSTOSCOPY AND TRANSCERVICAL INSEMINATION VET-S-CYST 119-132 9 ENDOSCOPY IN BIRDS AND SMALL EXOTIC ANIMALS VET-S-B 133-140 VITOM® 25 SYSTEM – VISUALIZATION SYSTEM FOR VET-S-VITOM 141-156 10 OPEN SURGERY WITH MINIMAL ACCESS VET-S-UNITS-INTRO, UNITS AND ACCESSORIES U 1-52 11 VET-S-UNITS EXCERPT FROM TELEPRESENCE, VET-S-DOK-HD, VET-S-DOK-3D, VET-S-DOK-TRI, VET-S-DOK-TELE, IMAGING SYSTEMS – DOCUMENTATION, TP 1-140 12 VET-S-TP-AIDA, VET-S-DOK-MEDIA, ILLUMINATION – EQUIPMENT CARTS VET-S-DOK-L, VET-S-DOK-V, VET-S-TP-SET EXCERPT FROM HYGIENE, MAINTENANCE, VET-S-CL CL 1-56 13 STERILIZATION, STORAGE TECHNIQUES 14 COMPONENTS / SPARE PARTS VET-S-SP SP 1-44 Not all the products listed in this document are certified according to Regulation 2017/745/EU. For this reason, some products requiring certification under this regulation may not be available in these countries.
    [Show full text]