Schmersal Protect Safety Controllers
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Time Delay Relays – Application Data
Time Delay Relays – Application Data Definition: Time Delay is defined as the controlled period between the functioning of two events. A Time Delay relay is a combination of an electromechanical output relay and a control circuit. The control circuit is comprised of solid state components and timing circuits that control operation of the relay and timing range. Typical time delay functions include On-Delay, Repeat cycle (starting off), Interval, Off-Delay, Retriggerable One Shot, Repeat cycle (starting on), Pulse Generator, One Shot, On/Off Delay, and Memory Latch. Each function is explained in the table below. Time delay relays have a broad choice of timing ranges from less than one second to many days. There are many choices of timing adjustments from calibrated external knobs, DIP switches, thumbwheel switches, or recessed potentiometer. The output contacts on the electromechanical output relay are direct wired to the output terminals. The contact load ratings are specified for each specific type of time delay relay. Understanding the differences between all the functions available in time delay relays can sometimes be a daunting task. When designing circuits using time delay relays questions such as: “What initiates a time delay relay?” “Does the timing start with the application or release of voltage?” “When does the output relay come on?” must be asked. Time delay relays are simply control relays with a time delay built in. Their purpose is to control an event based on time. The difference between relays and time delay relays is when the output contacts open & close: on a control relay, it happens when voltage is applied and removed from the coil; on time delay relays, the contacts will open or close before or after a pre-selected, timed interval. -
Installation Instructions
T P --- P R H --- A , --- B , T P --- N R H --- A , --- B Performance™ Series Edger Thermidistat™ Control Installation Instructions A07049 A07048 Programmable Control Non--Programmable Control Designed and Assembled in the USA. NOTE: Read the entire instruction manual before starting the installation. US patents: US7287709 B2, US20080147242 A1, USD582800 SI, US20060165149 A1, US6956463 B2. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS................................ 1 INTRODUCTION.......................................... 2 INSTALLATION CONSIDERATIONS.......................... 3 INSTALLATION........................................... 7 SYSTEM START--UP AND CHECKOUT...................... 45 OPERATIONAL INFORMATION............................ 55 TROUBLESHOOTING..................................... 60 WIRING DIAGRAMS...................................... 64 THERMIDISTAT CONTROL CONFIGURATION RECORD....... 84 SAFETY CONSIDERATIONS Read and follow manufacturer instructions carefully. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage Thermidistat Control. Recognize safety information. This is the safety--alert symbol . When you see this symbol on the equipment and in the instruction manual, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING,andCAUTION.These words are used with the safety--alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. -
Transportation Applications Transport Your Business to a Better Place: Leading the Race
Product Range Guide Transportation Applications Transport your business to a better place: leading the race. Honeywell is committed to providing the right product for your application. Whether you need a standard product or a highly customized solution, our sales and engineering teams have decades of experience in the Transportation industry. We understand your applications and work diligently to ensure we provide a solution that optimally meets your technical and financial needs. Our unique combination of a broad product portfolio, deep technical capabilities and extensive application experience culminates into a powerful ability to meet your design needs. Table of Contents Introduction ................................... 2-3 Transportation product applications .......... 4-5 Speed and Direction Sensors ....................6 SMART Position Sensors .........................7 Non-contact Hall-effect Sensors & Pots .........8 Hall-Effect & Magnetoresistive Sensors. 9 Pressure and Vacuum Switches .............10-11 Board-Mount & Heavy-Duty Transducers ...12-13 Packaged Temperature Probes ..............14-15 Key and Rotary Switches ....................... 16 Shifters ........................................ 16 Push-Pull/eStop Switches ..................... 17 Hour Meters ................................... 17 MICRO SWITCH Toggle Switches .............. 18 MICRO SWITCH Basic Switches ................ 19 MICRO SWITCH Limit Switches .............20-21 Magnetoresistive Sensor ICs ................... 22 Hall-effect Digital/Linear Sensor ICs .......... -
Addressable Fire Alarm Control Panel Installation and Operation Manual
6700 Addressable Fire Alarm Control Panel Installation and Operation Manual Document LS10148-001SK-E Rev:C 09/28/2017 ECN: 17-0555 Fire Alarm & Emergency Communication System Limitations While a life safety system may lower insurance rates, it is not a substitute for life and property insurance! An automatic fire alarm system—typically made up of smoke Heat detectors do not sense particles of combustion and alarm detectors, heat detectors, manual pull stations, audible warning only when heat on their sensors increases at a predetermined rate devices, and a fire alarm control panel (FACP) with remote notifica- or reaches a predetermined level. Rate-of-rise heat detectors may tion capability—can provide early warning of a developing fire. be subject to reduced sensitivity over time. For this reason, the Such a system, however, does not assure protection against prop- rate-of-rise feature of each detector should be tested at least once erty damage or loss of life resulting from a fire. per year by a qualified fire protection specialist. Heat detectors are An emergency communication system—typically made up of an designed to protect property, not life. automatic fire alarm system (as described above) and a life safety IMPORTANT! Smoke detectors must be installed in the same communication system that may include an autonomous control room as the control panel and in rooms used by the system for the unit (ACU), local operating console (LOC), voice communication, connection of alarm transmission wiring, communications, signal- and other various inter-operable communication methods—can ing, and/or power. If detectors are not so located, a developing fire broadcast a mass notification message. -
Lighting Controls
LIGHTING CONTROLS HUMIDITY CONTROLS LIGHTING Kele Provides System and Zone Controls, with a Wide Variety of Peripheral Sensors and Switches. DLM Series | p. 615 AF16 Series | p. 664 LX-24 | p. 624 WSD Series | p. 637 CI-24 | p. 626 ET Series | p. 674 LIGHTING CONTROLS Products manufactured MODEL/SERIES PAGE in the United States Emergency Lighting Control ELCU-100 — WattStopper Emergency Lighting Control . 666 Products that are ELCU-200 — Emergency UL924 Bypass/ Shunt Relays . 668 new to the catalog ESR Series — Functional Devices UL924 Emergency Bypass / Shunt Relays . 670 Light Sensors MK7-B Series — PLC-Multipoint Celestial Self-Contained Ambient Light Sensors, Voltage Based . 643 PSR-1, PSR-1-T — Kele Photo-Sensitive Resistor . 645 K, LC Series — Photo Switches . 647 EM Series — Photo Switches . 649 MAS Series — PLC-Multipoint Self-Contained Ambient Light Sensors, Current Based . 650 Lighting Contactors and Relays HDR — Relay 5 Wire with Override and Connector . 660 RR-7, RR-9 — GE Lighting Relays . 661 2R7CDD, 2R9CDD — ILC Lighting Relays . 663 AF16 Series — ABB Lighting Contactors . 664 LIGHTING CONTROLS LS7K Series — AEG Lighting Contactors . 665 LMCP Series | p. 613 Lighting Panels and Control Products RP Basic Series — BlueRidge Relay Panels . 609 ZC Basic Series — BlueRidge Lighting Zone Controller . 611 LMCP Series — WattStopper Lighting Integrator Panels with Digital Lighting Management (DLM) Support . 613 DLM Series Digital Lighting Management — Digital Lighting Controls . 615 LC8 Series — WattStopper Modular Contractor Panel . .. 618 CX Series Commercial Lighting Control Panels — Standalone Programmable Lighting Control Panel . 620 ILC Apprentice II — Programmable Lighting Control Panel . 622 PIL-1 — Kele Pulse Initiator . 658 LDIM2 — Kele Fluorescent Dimming Control Module . -
Float Type Level Switches Contents Page Start Single Point Small Size Engineered Plastic
INTRODUCTION Float Type Level Switches Contents Page Start Single Point Small Size Engineered Plastic ........................................... A-2 GEMS Level Switches operate on a direct, Alloy ........................................................................ A-8 simple principle. In most models, a float encircling a stationary stem is equipped Large Size PERMANENT with powerful, permanent magnets. As MAGNET Engineered Plastic .........................................A-12 the float rises or lowers with liquid level, Alloy ......................................................................A-13 the magnetic field generated from within FLOAT the float actuates a hermetically sealed, Specialty Switches ...............................................A-20 magnetic reed switch mounted within the HERMETICALLY stem. The stem is made of non-magnetic SEALED MAGNETIC REED SWITCH Leak Detection .......................................................A-22 metals or rugged, engineered plastics. When mounted vertically, this basic design provides a consistent accuracy of ±1/8 inch. Multi-station versions use a separate reed switch for each level point being monitored. Side-mounted units use different actuation methods because of their horizontal attitude. The basic principle, however, is the same: as a direct result of rising or falling liquid, a magnetic field is moved into the proximity of a reed switch, causing its actuation. N Reed Switch Reliability – SINGLE POINT LEVEL SWITCHES GLASS The durable construction of these reed switch designs ensures long, trouble- REED SWITCH ENVELOPE free service. Because the effects of shock, wear and vibration are minimized, these hermetically sealed switches provide precise S repeatability with no more than 1% deviation. The switch actuation points N S remain constant over the life of the unit. See “Reed Switch Protection” in MAGNET Appendix X for information on extending the life of GEMS Level Switches. -
Uninterruptible Power Supply
UPS UNINTERRUPTIBLE POWER SUPPLY CATALOGUE COMPANY PROFILE Inform Electronic, one of the European leading power solution specialist, is established in 1980 with the aim of designing and building industrial electronic systems. Soon after, it diversified into the production, and marketing of standard professional electronic equipment, and special projects. The company always combines its experience with its innovative identity and is recognized by its worldwide technology leading character. Right business understanding of Inform makes the company one of the most wanted brands in the world with its exceptional growth ratio. The Company has 31,000 m² closed production area, committed to the manufacturing of electrical products and electronic equipments. Analysing infrastructural conditions, and customer needs, the company decided to provide complete solutions. Inform product range varies from Uninterruptible Power Supply (UPS) Systems, Voltage Regulators, to DC Power Supply, Telecom Equipments, Battery chargers, Inverters, 19” rack cabinets and other electrical products and electronic equipments. Since its foundation, INFORM ELECTRONIC has based its strategy on below main policies: Quality understanding for its products and services, Tailored solutions to specific customer needs, Customer satisfaction and happiness, After sales service and support Continuous improvement for operational excellence and advanced technology Inform is an official ISO certified company. The company has also Gost, Soncap, and CE certifications. All the Inform products are designed and produced with the worldwide quality understanding, and ISO rules. Inform was acquired by Legrand Group in 2010. Legrand is global specialist in electrical and digital building infrastructures. The Group has direct presence in more than 70 countries and number of employee is more than 31.000 people. -
Room Humidistat Specification & Installation Instructions
Room Humidistat Specification & Installation Instructions Features: HRO20 • Attractive modern look with large LCD and backlight • Icons driven information and 1 line of text • External humidity sensor input • Humidification and dehumidification indicator • Multi level lockable access menu • Lockable Set point / Control mode • Window/outside temperature sensor input • Celsius or Fahrenheit scale selectable Technical Data HRO20 Actual humidity (0-100 %RH), 0-10 Vdc / 2-10 Vdc Humidity set point (0-100 %RH), 0-10 Vdc / 2-10 Vdc Humidification proportional control signal, 0-10 Vdc / 2-10 Vdc Outputs Dehumidification proportional control signal, 0-10 Vdc / 2-10 Vdc Humidification dry contracts 24 Vac, 1 A max, 3 A in-rush Dehumidification dry contracts 24 Vac, 1 A max, 3 A in-rush Window temperature sensor or outside temperature sensor (10 KΩ) External set point from Neptronic humidifier, Inputs external humidity sensor (0-10 Vdc / 2-10 Vdc) or high limit (0-10 Vdc / 2-10 Vdc) 1 alarm status digital input (24 Vac or dry contact) Power supply 22 to 26 Vac 50/60 Hz or 28 to 32 Vdc Power consumption 1 VA Set point range 10 - 90 %RH (in 1% increments) Sensor precision ± 3 % or better at 40 %RH and 23 ºC [73 ºF] Proportional band 2 % - 10 % for control signal Electrical connection 0.8 mm2 [18 AWG] minimum Operating condition 0 ºC to 40 ºC [32 ºF to 104 ºF], 0-95 %RH Storage condition -10 ºC to 50 ºC [14 ºF to 122 ºF], 0-95 %RH temperature compensation Automatic readjustment of set point from a window temperature sensor (SHW0-11) reset feature or external temperature sensor (STC8-11) Housing degree of protection IP 30 (EN 60529) Weight 80 g. -
Opus OK / Genie NKF1 Kitchen Extract Unit Installation and Maintenance
Installation and Maintenance NuAire Limited Western Industrial Estate Caerphilly, Mid Glamorgan CF83 1XH Opus OK / Genie NKF1 Telephone: 029 2088 5911 Leaflet 670525 Facsimile: 029 2088 7033 Email: [email protected] Kitchen Extract Unit www.nuaire.co.uk MARCH 2002 IMPORTANT WARNING Installation and servicing MUST be carried out by electrically quaIified personnel. The unit MUST BE TOTALLY ISOLATED from the electrical supply before removing covers. NOTE internal input socket will be exposed and E AIR may be live with the fan module removed. NU See ‘ISOLATION’ note on page 3. Contents Introduction Fig. 1. General view of a surface mounted unit. Typical arrangements Introduction Installation IMPORTANT! Nuaire's Opus/Genie Kitchen extract fan is designed to be Adjustment This unit is NOT designed installed in the area to be ventilated. The unit may be surface for installation directly mounted or semi recessed using the optional mounting Dimensions above a cooker or hob unit flange kit. Maintenance WARNING! Inlet is through two filters located on the front cover of the unit. which can be easily removed for cleaning. (Filters and Electrical front cover plus fixings are supplied bagged separately and are fitted during installation). Exhaust air is discharged through a 100mm dia. spigot on the rear of the unit. Typical arrangements Mounting in wall or ceiling. The Opus/Genie Kitchen unit has two speeds; 'Low', 'Boost' and an 'Off' position. Manual operation is by a pull cord. 'Low' and 'Boost' speeds can be selected by successive pulls, Fig. 2a Surface mounting a third pull returns the unit to the 'Off' position. -
Intrinsically Safe Barrier Relays NY2 and 8501TO
Intrinsically Safe Barrier Relays NY2 and 8501TO Class/File 8501 CONTENTS Description . .Page NY2 General Information . .2 NY2 Ordering Information. .3 NY2 Specifications . .4 NY2 Approximate Dimensions and Wiring Recommendations. .5 NY2 Wiring Diagrams. .6 8501TO General Information . .7 8501TO Ordering Information, Application Data, Approximate Dimensions. .8 Intrisically Safe Barrier Relays NY2 – Relays For Hazardous Locations General Information Intrinsically Safe (IS) Explosion prevention is a prime consideration in plants and facilities containing hazardous atmospheres and explosion-proof housings. The main fault with the explosion-proof system is that a single human error could create a high explosion probability. Prime examples are failing to tightly replace covers on explosion-proof housings, failing to shut off the power before removing the covers, and damaging the specially machined surfaces of these covers. Intrinsically safe (IS) systems are a means of providing automated control functions in explosive environments. Because of the inherent parameters of electronic circuits, no energy is released, under normal or abnormal conditions, of sufficient magnitude to ignite a specified atmosphere mixture. To design an effective intrinsically safe system, energy that enters the hazardous area must be limited. For electronic instrumentation, this is accomplished by controlling the voltages and currents that may enter the hazardous area. In addition, stored electrical energy in field instruments is limited to levels that cannot ignite a given atmosphere. Intrinsically safe relays, such as the NY2 and the Class 8501 Type TO relays, act as an energy barrier, limiting the voltage and current available in the hazardous area. They can be connected with any device having a dry contact (limit switch, magnetic switch, pushbutton, pneumatic-electric interfaces, etc.) or with NAMUR sensors. -
Time Delay Relays – Application Data
Time Delay Relays – Application Data Definition: Time Delay is defined as the controlled period between the functioning of two events. A Time Delay relay is a combination of an electromechanical output relay and a control circuit. The control circuit is comprised of solid state components and timing circuits that control operation of the relay and timing range. Typical time delay functions include On-Delay, Repeat cycle (starting off), Interval, Off-Delay, Retriggerable One Shot, Repeat cycle (starting on), Pulse Generator, One Shot, On/Off Delay, and Memory Latch. Each function is explained in the table below. Time delay relays have a broad choice of timing ranges from less than one second to many days. There are many choices of timing adjustments from calibrated external knobs, DIP switches, thumbwheel switches, or recessed potentiometer. The output contacts on the electromechanical output relay are direct wired to the output terminals. The contact load ratings are specified for each specific type of time delay relay. Understanding the differences between all the functions available in time delay relays can sometimes be a daunting task. When designing circuits using time delay relays questions such as: “What initiates a time delay relay?” “Does the timing start with the application or release of voltage?” “When does the output relay come on?” must be asked. Time delay relays are simply control relays with a time delay built in. Their purpose is to control an event based on time. The difference between relays and time delay relays is when the output contacts open & close: on a control relay, it happens when voltage is applied and removed from the coil; on time delay relays, the contacts will open or close before or after a pre-selected, timed interval. -
A Dry Contact Is a Potential Free Contact a Dry Contact Is a Contact That Does
A dry contact is a potential free contact A dry contact is a contact that does not provide voltage. For instance, the push-to-talk switch of a microphone, which just closes a circuit without providing voltage. A wet contact is a contact that will provide voltage when closed, like the switch on the wall that activates the 110 VAC outlet to turn a lamp on in a room. Potential free contact, voltage free contact and dry contact, they all are same. The dry contact is the contact which is physically operated with the main device, but not electrically connected to it. It is a voltage free on/off contact and can be used in any system. The auxiliary contact of the motor contactor used for the motor run feed back is the example of the dry contact. The contacts of the interposing relays are also dry contacts. - MS Perhaps you mean "dry circuit"? Contacts which need to work in such circuits are generally gold-plated, since the current and voltage levels are too low to break down the contaminant layWhat is a volt free contact? Answer: A volt free contact is a set of contacts that uses a voltage source from another location. The contacts are used to tie two individual pieces of electrical equipment together so the action on one will cause the other piece of equipment to operate. It is just a new way of using the older terminology "dry contacts". An example of use is the diesel start contacts on an automatic transfer switch. When the transfer switch is in the utility (hydro) position the diesel start "dry contacts" located in the transfer switch are open.