t AIBC t ect AIBC ect s . This office . This informed shall be Thinkspace CopyrightReserved and cannot be used or reproduced without without usedreproduced or be cannot and

LIGHTING PLAN SYMBOLS POWER PLAN SYMBOLS GENERAL SYMBOLS SCHEMATIC SYMBOLS ABBREVIATIONS a , of: partnership SURFACE OR SUSPENDED MOUNTED LUMINAIRE, 305x1220mm (1'x4') DUPLEX 5-15R RECEPTACLE # # # NOTE REFERENCE DRAW OUT LOW VOLTAGE CIRCUIT BREAKER AFF ABOVE FINISHED FLOOR DUPLEX 5-15R SWITCHED RECEPTACLE # # LOW VOLTAGE CIRCUIT BREAKER AFG ABOVE FINISHED GRADE # # EQUIPMENT REFERENCE of any variations from the information shown on thi on shown of any variations from the information scale Dodrawings. drawing. not Thinkspace Hoffart, AIBCRon Architect Mark Archit Mathiasen, Dust, AIBC Architec Architect Todd Henk Kampman, SURFACE OR SUSPENDED MOUNTED, 610x1220mm (2'x4') design and are plan This the exclusive property of Thinkspace Architecture, Planning, Interior Design (Thinkspace) of consent written GFI DUPLEX 5-15R RECEPTACLE C/W INTEGRAL GFCI PROTECTION HIGH VOLTAGE CIRCUIT BREAKER BMS BUILDING MANAGEMENT SYSTEM # REVISION NUMBER SURFACE OR SUSPENDED MOUNTED LUMINAIRE, 610x610mm (2'x2') DUPLEX 5-20R RECEPTACLE, T-SLOT DRAW OUT HIGH VOLTAGE CIRCUIT BREAKER CC CRASH CART

T ## WIRING HOME RUN I

RECESSED LUMINAIRE, 305x1220mm (1'x4') DUPLEX 5-20R SWITCHED RECEPTACLE CP CODE PINK N LOAD BREAK M

O R

I

E

T

W

P

SINGLE 5-20R RECEPTACLE DISCONNECT SWITCH CW CODE WHITE A RECESSED LUMINAIRE, 610x1220mm (2'x4') E

I 06/06/17

G

N

I

V

N

E

I SPLIT CIRCUIT DUPLEX 5-15R RECEPTACLE FUSE CM COFFEE MACHINE D

R

R D

RECESSED LUMINAIRE, 610x610mm (2'x2') L

O

I FIRE ALARM SYMBOLS %

D Date

U I

O QUADPLEX 5-15R RECEPTACLE TRANSFORMER DGS DIAGNOSTIC SET 5

C B B

9

STRIP LUMINAIRE (LENGTH AS PER LUMINAIRE SCHEDULE) F MANUAL STATION R R R R QUADPLEX 5-15R SWITCHED RECEPTACLE AUTOTRANSFORMER DIC DICTATION O O O O

F F F F

WALL MOUNTED LINEAR LUMINAIRE, 1220mm (4') 20A F WALL MOUNTED BELL ANNUNCIATOR D D D D DT DUAL TECHNOLOGY OCCUPANCY SENSOR E E E E QUADPLEX 5-20R RECEPTACLE TYPICAL DELTA-WYE ISOLATION TRANSFORMER U U U U RECESSED LUMINAIRE / DOWN LIGHT F S S S S

S S S S

WALL MOUNTED BELL ANNUNCIATOR AND STROBE Description 20A I I I I QUADPLEX 5-20R SWITCHED RECEPTACLE # DY DRYER SURFACE MOUNTED OR SUSPENDED LUMINAIRE F WALL MOUNTED HORN CURRENT TRANSFORMER (# INDICATES NUMBER OF CTs IN GROUP)

5 1 9 5

DW DISHWASHER 0 0 0 1 2 USB DUPLEX 5-15R RECEPTACLE WITH TWO USB CHARGING PORTS - - - - WALL MOUNTED LUMINAIRE (S-STEP) F WALL MOUNTED HORN AND STROBE ZERO SEQUENCE CURRENT TRANSFORMER 0 1 1 1

1 1 1 1 EL EXAMINATION LIGHT - - - - 4 USB 8 8 8 8 DUPLEX 5-15R RECEPTACLE WITH FOUR USB CHARGING PORTS F 1 1 1 1

BOLLARD OR IN-GROUND LUMINAIRE WALL MOUNTED STROBE 0 0 0 0

POTENTIAL TRANSFORMER (# INDICATES NUMBER OF PTs IN GROUP) Date # ER EXISTING DEVICE IN RELOCATED POSITION 2 2 2 2 SPECIAL RECEPTACLE (TYPE AS INDICATED) POLE MOUNTED LUMINAIRE (SINGLE HEAD) F CEILING STROBE Issued Issued For Revisions No. EX EXISTING DEVICE TO REMAIN 1 2 3 4 REEL CORD RECEPTACLE F WALL MOUNTED FIRE SPEAKER LUMINAIRE ON EMERGENCY CIRCUIT (INDICATED BY SHADING) FAX FAX MACHINE FLOOR MOUNTED DUPLEX RECEPTACLE F CEILING MOUNTED FIRE SPEAKER AUTOMATIC TRANSFER SWITCH C/W SINGLE ISOLATION/BYPASS DOTS DENOTES SUSPENDED LUMINAIRE G LH FHD FAUCET / HAND DRYER COMBINATION CEILING MOUNTED DUPLEX RECEPTACLE F WALL MOUNTED FIRE SPEAKER WITH STROBE CEILING MOUNTED EXIT SIGN (TEXT ON SHADED SIDES, ARROWS AS INDICATED) GF GROUND FAULT CIRCUIT INTERRUPTER DIRECT POWER CONNECTION TO EQUIPMENT TERMINAL BOX F CEILING MOUNTED FIRE SPEAKER WITH STROBE HD HAND DRYER WALL MOUNTED EXIT SIGN (TEXT ON SHADED SIDES, ARROWS AS INDICATED) SERVICE COLUMN / PACK POLE (NUMBER OF OUTLETS AS INDICATED) CO CARBON MONOXIDE DETECTOR AUTOMATIC TRANSFER SWITCH C/W DUAL ISOLATION/BYPASS G LH HK HOUSEKEEPING TRACK LIGHT (# OF HEADS AS SHOWN, LENGTH AS INDICATED) SA J WALL MOUNTED JUNCTION BOX 120V SMOKE ALARM (CO DENOTES INTEGRAL CARBON MONOXIDE DETECTOR) CO IG ISOLATED GROUND LINE VOLTAGE SWITCH J FLOOR MOUNTED JUNCTION BOX H FIRE ALARM HEAT DETECTOR (RATE OF RISE UNLESS OTHERWISE INDICATED) IR INFRARED OCCUPANCY SENSOR 2-GANG LINE VOLTAGE SWITCH J OWNER POWER METER 200, 1628 Dickson Avenue Kelowna V1Y BC 9X1 Phone: (250) 860-2257 Fax: (250) 860-2523 www.cima.ca CEILING MOUNTED JUNCTION BOX S FIRE ALARM SMOKE DETECTOR DMM 3-GANG LINE VOLTAGE SWITCH JB JUNCTION BOX ELECTRICAL PANEL DA FIRE ALARM DUCT SMOKE DETECTOR 4-GANG LINE VOLTAGE SWITCH NORMALLY OPEN CONTACT MCC MOTOR CONTROL CENTER PANEL (TYPE AS INDICATED - SECURITY, LIGHTING RELAY, ETC.) FAA FIRE ALARM ANNUNCIATOR PANEL LOW VOLTAGE SWITCH (30V OR LESS) NORMALLY CLOSED CONTACT MGAP MEDICAL GAS ALARM PANEL GROUNDING / BONDING BUS BAR FACP FIRE ALARM CONTROL PANEL D LOW VOLTAGE DIMMER SWITCH G GENERATOR MW MICROWAVE VFD VARIABLE FREQUENCY DRIVE CACF CENTRAL ALARM & CONTROL FACILITY D LINE VOLTAGE DIMMER SWITCH DELTA CONNECTION N/C NORMALLY CLOSED MOTOR M MAGNETIC DOOR HOLDER OS LOW VOLTAGE SWITCH c/w OCCUPANCY SENSOR WYE CONNECTION N/O NORMALLY OPEN MOTOR c/w DISCONNECT SWITCH PS PRESSURE SWITCH OS LINE VOLTAGE SWITCH c/w OCCUPANCY SENSOR GROUND CONNECTION OC ON CENTER DISCONNECT SWITCH FS FLOW SWITCH VPIR LOW VOLTAGE SWITCH WITH PASSIVE INFRARED VACANCY SENSOR POTHEAD PL PATIENT LIFT FUSED DISCONNECT SWITCH TS TAMPER SWITCH VDT PM PATIENT MONITOR LOW VOLTAGE SWITCH WITH DUAL TECHNOLOGY VACANCY SENSOR COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT CAPACITOR DA DRY ALARM SWITCH VPIR LINE VOLTAGE SWITCH WITH PASSIVE INFRARED VACANCY SENSOR SURGE PROTECTIVE DEVICE PTR PRINTER MAGNETIC MOTOR STARTER ELR END OF LINE RESISTOR VDT RNG RANGE LINE VOLTAGE SWITCH WITH DUAL TECHNOLOGY VACANCY SENSOR T THERMOSTAT LIGHTNING ARRESTOR CM FIRE ALARM CONTROL MODULE P LINE VOLTAGE SWITCH c/w PILOT LIGHT MP GROUND BUS RE REMOVE EXISTING DEVICE MANUAL MOTOR STARTER c/w PILOT LIGHT MM FIRE ALARM MONITOR MODULE 2 REF REFRIGERATOR LINE VOLTAGE TWO POLE SWITCH PANEL PANEL CONDUIT STUB ISO FIRE ALARM FAULT ISOLATION MODULE 3 N2A N2A PANELBOARD RL RELOCATE EXISTING DEVICE LINE VOLTAGE THREE WAY SWITCH CONDUIT UP 42POS 4 RP REPLACE EXISTING DEVICE WITH NEW DEVICE LINE VOLTAGE FOUR WAY SWITCH CONDUIT DOWN PUSH PULL SWITCH T RR REMOVE AND RE-INSTALL DEVICE IN ORIGINAL POSITION ELECTRONIC PROGRAMMABLE TIMER SWITCH DOT DENOTES DEVICE MOUNTED ABOVE MILLWORK COUNTERTOP SECURITY SYMBOLS M REVENUE METER SB SOUNDER BASE K KEY OPERATED SWITCH FORCED AIR WALL HEATER WALL MOUNTED SECURITY CAMERA, FIXED DM DIGITAL MULTIMETER SPD SURGE PROTECTIVE DEVICE OS WALL MOUNTED INFRARED LIGHTING OCCUPANCY SENSOR (DT=DUAL TECHNOLOGY) BASE BOARD HEATER (BLACK SQUARE INDICATES INTEGRAL THERMOSTAT) PTZ WALL MOUNTED SECURITY CAMERA, PAN/TILT/ZOOM A AMMETER SWD STACKED WASHER/DRYER OS CEILING MOUNTED INFRARED LIGHTING OCCUPANCY SENSOR (DT=DUAL TECHNOLOGY) GROUND ROD CEILING MOUNTED SECURITY CAMERA, FIXED V VOLTMETER PC PC PHOTOCELL (EXTERIOR, TYPE AS INDICATED) PTZ CEILING MOUNTED SECURITY CAMERA, PAN/TILT/ZOOM TR TAMPER RESISTANT K /KEY INTERLOCK TV TELEVISION DS DS DAYLIGHT SENSOR (INTERIOR PHOTOCELL, TYPE AS INDICATED) CR CARD READER CONNECTION EMERG. LTG. BATTERY PACK (# OF LAMPS AS SHOWN) COMMUNICATION SYMBOLS CR K CARD READER / KEY PAD COMBINATION TYP TYPICAL WALL MOUNTED TELEPHONE OUTLET RESISTOR WP WEATHERPROOF EMERG. LTG. BATTERY PACK AND EXIT COMBO K IA SECURITY KEY PAD (IA-INFANT ABDUCTION, PW-PATIENT WANDERING) # SPACE HEATER WS WASHER WALL MOUNTED DATA OUTLET (# DENOTES NUMBER OF OUTLETS) KO KEY SWITCH OVERRIDE CEILING MOUNTED EMERG. LTG. REMOTE HEAD (# OF LAMPS AS SHOWN) LIGHT # WALL MOUNTED VOICE & DATA OUTLET (# DENOTES NUMBER OF OUTLETS) PUSHBUTTON #° OCCUPANCY OR MOTION SENSOR BEAM SPREAD ANGLE WALL MOUNTED EMERG. LTG. REMOTE HEAD (# OF LAMPS AS SHOWN) # PROBE SENSOR - WET WELL APPLICATION FLOOR MOUNTED VOICE & DATA OUTLET (# DENOTES NUMBER OF OUTLETS) RE REQUEST-TO-EXIT PUSHBUTTON WIRELESS CONTROL # FLOW SWITCH, NORMALLY CLOSED CEILING MOUNTED VOICE & DATA OUTLET (# DENOTES NUMBER OF OUTLETS) RE REQUEST-TO-EXIT MOTION SENSOR FLOW SWITCH, NORMALLY OPEN WIRELESS ACCESS POINT PROVIDE DATA OUTLET P PANIC/DURESS PUSHBUTTON LEVEL SWITCH, NORMALLY CLOSED DRAWING LIST C WALL MOUNTED OUTLET (C = CATV, F = FIBRE, I = INTERCOM, H = HDMI, X = XLR) S BUZZER C LEVEL SWITCH, NORMALLY OPEN LIGHTING ANNOTATION LEGEND CEILING MOUNTED OUTLET S SECURITY HORN SHEET NUMBER SHEET NAME C PRESSURE SWITCH, NORMALLY CLOSED E-000 SYMBOL LEGEND LUMINAIRE TYPE (SCHEDULE REFERENCE) FLOOR MOUNTED OUTLET ML ELECTROMAGNETIC LOCK A E-100 EXISTING ELECTRICAL PLAN SWITCH LEG TEL PRESSURE SWITCH, NORMALLY OPEN a SUITE TELEPHONE TERMINATION BOX ES ELECTRIC STRIKE PANEL AND CIRCUIT E-200 ELECTRICAL RENOVATION PLAN X-13 TV PUSH BUTTON MOMENTARY CONTACT, NORMALLY CLOSED SUITE CATV TERMINATION BOX DP DOOR POSITION SWITCH E-300 SCHEDULES PUSH BUTTON MOMENTARY CONTACT, NORMALLY OPEN WP WINDOW POSITION SWITCH E-301 SCHEDULES NORMALLY-CLOSED, TIMED-CLOSED CONTACT (TIME DELAY ON DE-ENERGIZATION) E-400 SPECIFICATIONS M CEILING MOUNTED SECURITY MOTION DETECTOR PUBLIC ADDRESS & AUDIO-VISUAL SYMBOLS NORMALLY-CLOSED, TIMED-OPEN CONTACT (TIME DELAY ON ENERGIZATION) M WALL MOUNTED SECURITY MOTION DETECTOR S WALL MOUNTED SPEAKER NORMALLY-OPEN, TIMED-OPEN CONTACT (TIME DELAY ON DE-ENERGIZATION) G GLASS BREAK DETECTOR S CEILING MOUNTED SPEAKER NORMALLY-OPEN, TIMED-CLOSED CONTACT (TIME DELAY ON ENERGIZATION) PWC PATIENT WANDERING SYSTEM READER CONTROLLER H HORN THERMAL SWITCH, NORMALLY CLOSED PWD PATIENT WANDERING SYSTEM DETECTOR/EXCITER SENSOR C CHIME THERMAL SWITCH, NORMALLY OPEN IAC INFANT ABDUCTION SYSTEM READER CONTROLLER B BUZZER , NORMALLY CLOSED IAD INFANT ABDUCTION SYSTEM DETECTOR/EXCITER SENSOR VC VOLUME CONTROL LIMIT SWITCH, NORMALLY OPEN M MICROPHONE OUTLET O CLOCK SYMBOLS H A HAND-OFF-AUTO SWITCH WALL MOUNTED SINGLE FACED CLOCK INDUCTOR/REACTOR/CHOKE COIL WALL MOUNTED DOUBLE FACED CLOCK

MOTOR OVERLOAD 01 ET WALL MOUNTED ELAPSED TIME CLOCK - 11 MAGNETIC MOTOR STARTER - CEILING MOUNTED SINGLE FACED CLOCK

MANUAL MOTOR STARTER Scale NTS Date 2018 CEILING MOUNTED DOUBLE FACED CLOCK COMBINATION MAGNETIC MOTOR STARTER D/I DOOR INTERLOCK SWITCH V2L 5R8 V2L BREAK LINE CONTINUATION BREAK PRINCE GEORGE, B.C. PRINCE GEORGE, 177 VICTORIA STREET 177 - 200 Project NATIONS HEALTH FIRST AUTHORITY Drawing FNHA PRINCE GEORGEOFFICE PRINCE FNHA RENO. SYMBOL LEGEND SYMBOL Project Number Project Number Sheet K000293A E-000

PRINTED: 11/15/2018 2:50:12 PM t AIBC t ect AIBC ect s

1 2 3 4 5 12 3 4 5 N

J J office . This informed shall be EX EX RE 2C-51 2CA-6 2CA-16 2C-53 2C-53 J 2C-49 RE EX EX2 RP EX EX EX RE 2C-53 2C-53 E E 2CA-11 RE RE Thinkspace

2C-51 EX EX EX RL RL RL RL RL RL EX EX EX

2 s

EX EX 4 4 4 4 4 CopyrightReserved 4 without used reproduced be or cannot and s J 274 s 274 3 HC2-1 J J 2C-30 EX a , of: partnership LAB 2C-38 RE RE 2C-51 LAB EX RE 2C-30 2C-19 EX RL 2CA-14 D 4

RP C RE J RE s EX 2CA-5 This plan and design and are plan This the exclusive property of Thinkspace Architecture, Planning, Interior Design (Thinkspace) Thinkspace written consent of consent written of any variations from the information shown on thi on shown of any variations from the information Doscale drawings. drawing. not EX RL Hoffart,Ron AIBC Architect Mark Archit Mathiasen, Dust, AIBC Architect Architec Todd Henk Kampman,

3 HC2-4 RE RE RL RL RL

2 EX EX RL s 2C-19 V6 s 4 4 4 EX2 EX 220 RE D5 220

T 2C-13 I

2C-15 N SUITE RE J SUITE EX EX EX EX M EX EX O R

RE I

RP 2C-40 RP E T 2C-15 s

W DATA P

A 2C-63 E

I 09/05/18

2C-21 G 2C-36 RE RE RE RE N

250 250 I RACK V RE 2 N

E

I RE RE RE D

EX R

R D

SUITE EX EX SUITE L

O EX I 2C-51 %

D Date

U I 2C-13 O 2 5

RL C B B HC2-32 9 RE RE R R R R

O O O O

F F F F 2C-42 EX RE RE EX EX EX RE D D D D

E E E E 273 RE s 273

2C-42 RE RE RE RE U U U U D RE D S S S S

S S S S OPEN OFFICE 1 RE 2C-28 OPEN OFFICE D I I I I

RE s RE 2C-30 EX EX RE RE RE s RE 5 1 9 5 RE 0 0 0 1

- - - -

EX 0 1 1 1

RE 2C-30 1 1 1 1 EX RE 2C-51 - - - -

8 8 8 8

2C-63 1 2C-15 RE 1 1 1 1 1 EX s EX EX RE RE RE RE

0 0 0 0

EX Date Description RE s EX 2 2 2 2 2C-47 RE 2C-34 RE RE RE RE 2 RE RE EX EX EX RE 1 Issued For Revisions No. HC2-9 3 RE 1 2 3 4 EX 2 EX EX 3 HC2-10 EX EX EX RE 2C-47 EX RE CR 200 200 1 EX ES EX CISCO WIFI MOUNTED ON RP DP EX STAIRS EX STAIRS RE RE RE RE RE RL M 2C-51 CEILING AND EX J EX RE RE EX RE WIRED DOWN WALL. REMOVE EX EX EX EX 2C-19 2C-21 2C-53 TEL/DATA 1 1 RE RE

F F F F RE RE RE EX EX EX 2

OUTLET AND WIRING AND EX 2C-21 BOARD s EX s REPLACE WITH NEW CEILING IN-WALL CABLING 272 RE 2C-19 RE A-3 30A TWIST-LOCK 272 OUTLET. 275 TO MONITOR RERE RE 271 275 EX 271 OFFICE 2C-19 GFI GFI GFI A-17 3 OFFICE RE RE RE RE RE HC2-11 A-4 A-9SERVER A-7 SERVER OFFICE 4 OFFICE 200, 1628 Dickson Avenue Kelowna V1Y BC 9X1 Phone: (250) 860-2257 Fax: (250) 860-2523 www.cima.ca EX3 EX EX EX E-100 EX

INTRUSION ALARM C C

M 2CA-35 s PANEL A 2 s RE EX EX PANEL RE DATA RACKS FEMALE W.C. MALE W.C. 260 A-16 A-18 FEMALE W.C. MALE W.C. 260 EX 271 EX OPEN OFFICE RE RE 271 RE RE OPEN OFFICE

3 HC2-16 LAN 2CA-35 EX EX EX LAN EX s RE4 RE s RE 2 2C-45 HC2-14 EX 3 2C-55 RP RE EX 2C-61 EX E-100 ST. ST. ST. ST. EX EX 276 J J 276 EX RE RE EX EX

RE RE WALL MOUNTED TV s OPEN OFFICE CCTV DVR OPEN OFFICE

IN-WALL CABLING FROM EX EX EX RE RE EX EX RE2 RE s HC2-19 2C-43 LOW LEVEL TO BEHIND EX TV TO BE REMOVED 2C-55 EX EX EX ES A-6 A-6 RE A-8 RP RE 270 201 RE RE 3 RE J 270 201 EX RECEPTION FOB ACCESS CORRIDOR RECEPTION CORRIDOR

3 HC2-17 RL J J J EX EX

K RE CR RE s s s EX EX D-33 s 2C-68 D-9 RE 2 RE RE RE RE RE 2CA-36 RE RE RE 2C-31 D-17 2CA-34 RP EX RE EX 1 EX EX J RE RE EX 2 EX EX EX 2CA-38 EX EX EX RL EX EX EX EX 2C-35 2C-35 2CA-40 2CA-38 EX B RE RE B J 2C-68 2C-70 EX 2C-70 EX J 4 EX 2CA-42 1 RE RE DW RE EX EX EX EX EX 2C-61 F 2C-31 2C-31 RP RP 2CA-38 2C-41 RE RL RL EX EX RE RE EX EX

278 282 278 282 EX

s s s s s RR 4 4 s s COPY OFFICE RE D COPY OFFICE 2C-22 2C-22 HC2-26 HC2-30 F 281 284 EX 2CA-28 281 EX 284 EX EX EX 3 3 OFFICE 3 2CA-22 2CA-28 RP EX EX RE OFFICE RE OFFICE RP RP RP 288 EX 2 C OFFICE 288 J 277 J RE 277 RE 2C-37 F OPEN OFFICE 4 EX OPEN OFFICE MEETING J EX RL MEETING EX EX SHUB-M 1 C RE RL

EX EX O EX RE RE RE RE RE s s s s 2C-59 S 4 s RE EX EX HOLD-UP BUTTON 2CA-28 a 2 D45 RE RL RE 4 EX RE 4 RL RE RP RP 2 EX EX RP RL RL EX EX EX a 285 2CA-40 EX 285 RE RL HC2-20 3 EX EX RE 4 4 RL RE 4 2C-33 2C-33 RP 2CA-55 RE RE RE a a 2C-37 EX RE OFFICE OFFICE 4 2C-59 EX 2 287 J 4 287

EX EX C 280 283 2C-33 286 RL RL 280 EX 283 RL EX 286

s s HC2-25 s RE RE

s s J EX OFFICE 4 s 4 OFFICEa a J 279 RP OPEN OFFICE 3 2C-24 OFFICE J OFFICE 279 OPEN OFFICE OFFICE OFFICE RP RP 4 OFFICE EX EX +914mm OFFICE RL CISCO WIFI MOUNTED ON CEILING AND EX J AFF 2CA-28 EX RE RE 2CA-28 EX a a a a a WIRED DOWN WALL. REMOVE OUTLET 2C-59 EX 2CA-40 2CA-57 A RE RE RE A AND WIRING AND REPLACE WITH NEW RP EX EX3 EX RP 2 EX EX1 RP RP EX J J +914mm J EX J CEILING OUTLET. HC2-24 HC2-28 AFF DASHED LINE DENOTES DASHED LINE DENOTES AREA OF RENOVATION AREA OF RENOVATION 1 EXISTING ELECTRICAL LAYOUT 2 EXISTING LIGHTING LAYOUT E-100 1 : 100 E-100 1 : 100 EXTERIOR LIGHTING HOA'S KANTECH KT-300 ABOVE DOOR FACP GENERAL NOTES T1 75 KVA PANEL 6A 1. ALL EXISTING 2'x4' FIXTURES ARE RECESSED, 2F32T8, 3500K WITH AIR SLOTS. PANEL 2CA KEYSCAN ACCESS MC1 2. EXISTING RECESSED POT LIGHTS LABELED WITH 'a' ARE MR16 LED. REMAINING LVRC CONTROL PANEL 6E EXISTING POT LIGHTS ARE 8" WITH SINGLE QUAD LAMP. ST. METER 2 MOUNTED BELOW 3. EXISTING CONTROLS ARE DOUGLAS LV CONTROLS TEL. BOX PANEL PANEL 2A 4. ALL JUNCTION BOXES ARE IN-WALL COVERED WITH BLANK DECORA COVER PLATE PANEL 2C-2 UNLESS OTHERWISE NOTED. PANEL 2C-1 PANEL 6C METER 1 5. ALL DEVICES SHALL REMAIN IN PLACE UNLESS EXPLICITLY NOTED OTHERWISE. PANEL 2K

TEL. CABINET (x2) 01 - 11 6. ALL LUMINAIRES TO BE REMOVED SHALL BE INVENTORIED, TAGGED AND HANDED EXISTING POWER LAYOUT - OVER TO OWNER. ELECTRICAL ROOM PANEL 6D2 TEL. ROOM Scale As indicated Date 2018 3 OFFICE LEVEL ELECTRICAL ROOM PANEL 2D1 7. ALL DEVICES SHOWN TO BE REMOVED SHALL BE COMPLETELY REMOVED FROM SITE BY THE CONTRACTOR IN A SUSTAINABLE MANNER INCLUDING WIRING BACK E-100 1 : 50 CIRCA TELECOM V2L 5R8 V2L TO ORIGIN. PROVIDE COVERPLATES FOR UNUSED OUTLET BOXES. CABINETS (x9) T3 8. EXTEND WIRING AS REQUIRED FOR DEVICES TO BE RELOCATED. TEL/DATA BOARD 300 KVA EF-1 TO EF-5 HOA'S AND JUNCTION BOX PRINCE GEORGE, B.C. PRINCE GEORGE, 177 VICTORIA STREET 177 MOUNTED ABOVE CAPACITOR BANK - DRAWING NOTES 200 C/T PULL 1 SECURITY CCTV MONITOR. PANEL 2M PANEL 6M CABINET SECTION

2 LUMINAIRE WAS NOT OPERATIONAL DURING SITE INSPECTION. KANTECH KT-300 3 REMOVE BOARD AND RECEPTACLES AND MOVE ALL EQUIPMENT TO LAN FIRST NATIONS NATIONS HEALTH FIRST AUTHORITY Project Drawing FNHA PRINCE GEORGEOFFICE PRINCE FNHA RENO. ROOM 271. ALL DATA OUTLETS AND CABLING EAST OF GRIDLINE 3 TO BE PLAN ELECTRICAL EXISTING REMOVED. NEW OUTLETS AND CABLING TO BE WIRED TO LAN ROOM 271 ON POWER FACTOR T2 DISTRIBUTION 600V, 3Ø, 4W BC HYDRO EXISTING FREE-STANDING DATA RACK. PROVIDE NEW PATCH PANELS AS EXISTING POWER LAYOUT CORRECTION CAPACITORS 75 KVA SECTION MAIN BREAKER METER REQUIRED. 4 OFFICE LEVEL TEL. ROOM 5 EXISTING P1 ELECTRICAL ROOM 4 LUMINAIRE TO BE RE-USED, RE-BALLASTED WITH NEW PROGRAM START E-100 1 : 50 BALLAST AND RE-LAMPED. E-100 NTS Project Number Project Sheet Number Sheet K000293A E-100

PRINTED: 11/15/2018 2:50:13 PM t AIBC t

ect AIBC ect

1 2 3 4 5 1 2 3 4 5 GROUND LEVEL CU-1 CU-2 ROUTE WIRING WITHIN BUILDING N WP WP office. This shall informed be TO LANDLORD'S SATISFACTION EX EX M 2CA-6 2CA-16 2C-53 2C-28 2C-49 2C-28 2C-53 EX EX 2 2 2C-21 E E EX EX EX 2 2C-53 DS 202 2C-21 202 ER ER ER DS DS ER Thinkspace BREAK RM 3 BREAK RM 2CA-11 227 2 227

EXEX EX CopyrightReserved

2C-36 without used be reproduced or cannot and EX SHARED OFFICE 2C-36 EX EX EX EX SHARED OFFICE 201 201 a , partnership of: 3 HC2-1 LAB 2C-38 EX LAB ER ER 2C-30 2C-40 2C-51 OS OS 2CA-14 2 EX OS GFI 2C-38 225 2C-36 EX 225 OS 226 I.T. ER 226 OS ER I.T. OS OFFICE OFFICE This plan and designand plan areThis the exclusive property of Thinkspace Architecture, Planning, Interior Design (Thinkspace) Thinkspace written consent of consent written Ron Hoffart,Ron AIBC Architect Mark Archit Mathiasen, Dust, AIBC Architect Architec Todd Henk Kampman, EX 2CA-5 this on of any shown variations from the information Doscaledrawing. drawings. not EX 2 ES OS 3 HC2-4 2C-30 2C-40 CR C ER EX EX ER 224 D1 224 228 2C-19 +2300 AFF OPEN OFFICE 228 OPEN OFFICE

T EX2 EX TEL. RM D2 TEL. RM I

N

M

O R

I

4 ER EX EXEX EX E EX EX T

W

P

M A

E

I 09/25/18

DS G

N

I 1 D2 D2 V

N

E

I

D

R

R D

L

O EX I

%

D Date

U I

O EX EX 5 EX 203 2C-51 203

C B B 2C-19 9 2 OPEN OFFICE OPEN OFFICE X1

HC2-32 230 230 R R R R

NURSE ST. NURSE ST. O O O O

F F F F

2C-34 2C-34 229 A-33 A-33 229 OS 3 SEC. ST. SEC. ST. OS X1 D D D D 3 2 ER EX ER D3 U/C LED STRIP LIGHT EXEX EX E E E E DP DP U U U U

S S S S

ES CR ES CR (TYPICAL) OS S S S S D D I I I I DP M RH1 ES EF-1 ER GFI F GFI EX EX 5 1 9 5

0 0 0 1

- - - -

CR 2C-13 0 1 1 1 231 T 231 RH1 1 1 1 1 K 2C-15 2C-15 EX ER ER - - - - EX SHIPPING SHIPPING OS D1 D1 8 8 8 8 2C-34 2C-51 RH1 ER 1 1 1 1 EX 0 0 0 0

2C-63 Date Description EX EX 3 3 2 2 2 2 EX EX 2C-47 4 2C-19 3 Issued For Revisions No. 2 A-35 2 ER ER 1 2 3 4 EX EX 3 M 3 D HC2-9 ES 3 OS EX 1 DP CR EX X1 EX HC2-10 EX EX EX X1 3 K RE CR +1500 AFF 2 ER 2C-47 EX D1 L1 D1 1 ES EX 223 ER OS 223 EX DP EX OFFICE EX EX OFFICE DSRE 2C-51 EX J EX 221 OS 3 221 BOARDROOM 3 BOARDROOM 204 F 204 ER OFFICE EX EX OFFICE EX D EX EX IN -WALL CABLING TO MONITOR 4 OS L1 AC-2 A-35 2 EX D1 D1 3 2C-36 OS ER RE HC2-11 200, 1628 Dickson Avenue Kelowna V1Y BC 9X1 Phone: (250) 860-2257 Fax: (250) 860-2523 www.cima.ca 205 222 205 222 ER DS TEL. RMEX3 EX PANEL A TEL. RM TEL. RM TEL. RM 3 EX EX 3 INTRUSION ALARM 2CA-35 FLOOR C EX C EX 4 3 3OS DP EX PANEL MOUNTED (TYP) ES 206 FEMALE W.C. MALE W.C. 206 FEMALE W.C. MALE W.C. L1 EX LAN. LAN. D1 D1 EX OS 3 HC2-16 CR RE 2CA-35 EX EX EX EX EX DATA RACKS 2 4

EX 2C-55 3 A-35 PROVIDE 25mmC TO 3 RH1 2C-61 EX 3 EX EX A-19 A-19 ARLINGTON BOX ABOVE. EX OS RH1 EX EX +254 AFF 4 CCTV DVR 2CA-35 A-33 3 D1 L1 D1 H H 3 EX EX EX EX EX DP 2 2H AC-1 EX X1 A-35 2 2C-55 EX EX ROPELIGHT. U/C 207 EX FOB ACCESS 2 207 ES K PROVIDE 2x25mmC RH1 OPEN OFFICE ES EX OPEN OFFICE POWER SUPPLY TO D D D D 3 X1 DP 1 TO T-BAR CEILING T1 DP X1 EX SPACE BE MOUNTED X1 3 HC2-17 RE CR EX EX EX RE CR WITHIN MILLWORK. D4 P2 A-25 D-9 D-33 +1500 AFF 1 P1 D-17 A-37 2 EX OS +1575 AFF A-23 A-29 1 EX 5 EX EX EX 2 EX EX EX EX 2CA-38 EX P2 ER K 2CA-40 2CA-38 EX EX EX ER EX EX EX EX 2C-35 2C-35 220 220 4 2C-70 EX 2C-70 B P2 B EX 2CA-42 EX EX EX 1 RECEPTION RECEPTION MW EX EX OS OS 2C-61 GFI GFI 2C-31 2C-31 2CA-38 D1 D1 J F A-21 D3 ER EX ER EX EX EX EX A-23 DW A-27 210 RR U/C LED STRIP LIGHT 210 OS OS OS 208 2C-22COPY 2C-22 HC2-26 ER 208 COPY KITCHEN EX (TYPICAL OF 2 SECTIONS) KITCHEN EX D1 D1 2C-59 F 3 3 216 3 216 EX EX EX 212 214 OFFICE 2CA-22 2CA-28 EX 2CA-28 212 214 OFFICE OFFICE OFFICE 2 C 3 OFFICE OFFICE 3 EX EX 3 T2 F OS D X1 EX X1 209 EX 209 EX EX SHUB-M MEETING EX 1 C MEETING D1 D1 D1 D1 D1 D1 OS ER 2C-59 EX EX EX EX HOLD-UP BUTTON 2CA-28 2C-59 D45 ER ER EX 3 RP OS 4 4 2 EX EX ER EX EX EX OS ER ER 3 A-31 EX EX 217 2CA-40 EX 217 HC2-20 213 215 OFFICE 213 215 OFFICE OFFICE 2C-33 OFFICE 2C-33 2CA-55 OS OFFICE OS OFFICE OS 2C-37 EX 211 219 ER ER 211 219 2C-59 OFFICE EX 2 OFFICE ER OFFICE ER OFFICE EX EX C 2C-33 218 EX ER 218 EX ER ER HC2-25 EX OFFICE OFFICE 3 2C-24 2 EX ER ER ER EX EX 2CA-40 2CA-28 EX 2CA-28 EX 2C-59 EX 2CA-57 A A 2 EX EX3 EX 2 EX EX 1 2 EX +914mm EX HC2-24 AFF DASHED LINE DENOTES EXISTING 347V LIGHTING CIRCUITS TO DASHED LINE DENOTES AREA OF RENOVATION BE RE -USED FOR NEW LAYOUTS. AREA OF RENOVATION CONTRACTOR TO RE -WIRE LIGHTING POWER AND CONTROLS TO SUIT NEW DESIGN SHOWN. CONNECT EXIT LIGHTS TO EXISTING EXIT LIGHT CIRCUIT. 1 RENOVATED ELECTRICAL LAYOUT 2 RENOVATED LIGHTING LAYOUT E-200 1 : 100 E-200 1 : 100 CASEGOOD/STAND -ALONE WORKSTATION NOTES DRAWING NOTES

25mm EMT TO SECOND ACCESS CONTROL JUNCTION POWER 1 SECURITY CCTV MONITOR. BOX. SECOND ACCESS CONTROL JUNCTION BOX TO 1. ALL POWER RECEPTACLES AND DATA OUTLETS FOR CASEGOOD/STAND-ALONE RUN 25mm EMT TO DOOR CONTROLLER. WORKSTATIONS SHALL BE PROVIDED ALONG THE NEAREST ADJACENT WALL. 2 MOUNT IN RECESSED ARLINGTON OUTLET BOX BEHIND TV. 70" TV SUPPLIED BY OTHERS TO BE CENTERED AT +2032mm (80") AFF. 150mm x 150mm ACCESS 20mm CONDUIT BETWEEN CONTROL JUNCTION BOX ON 3 MOUNT IN RECESSED ARLINGTON BOX +25mm ABOVE SHELF. SHELF JUNCTION BOXES SECURE SIDE NEAR CEILING MOUNTED 330mm (13") BELOW BOTTOM OF TV. DETAIL NOTES 150mm x 150mm 120V JUNCTION BOX ON SECURE SIDE NEAR 4 PROVIDE POKETHROUGH RECESSED FLOOR DEVICE FOR POWER AND DATA 1. REFER TO ARCHITECTURAL DOOR SCHEDULE AND PLANS FOR DOOR DETAILS. CEILING. CIRCUIT A-41. EQUAL TO LEGRAND EVOLUTION SERIES WITH CUSTOM FINISH. CONTRACTOR SHALL X-RAY EACH LOCATION AND RETAIN THE LANDLORD'S STRUCTURAL 2. COORDINATE THE SUPPLY AND INSTALL OF ALL EQUIPMENT WITH THE DOOR/HARDWARE ENGINEER TO REVIEW AND APPROVE THE PENETRATION IN WRITING PRIOR

20mm EMT 01 INSTALLER TO ENSURE A COMPLETE WORKING SYSTEM. TO PERFORMING THE WORK. COORDINATE WITH LANDLORD FOR WIRING - 11 STUB CONDUIT INTO DOOR WITHIN TENANT SPACE BELOW. - 3. DRILL DOOR FRAME TO MATCH DOOR POSITION . FRAME FOR DOOR POSITION 12mm EMT 12mm SWITCH Scale As indicated Date 2018 4. ALL CONDUIT SHALL BE 20mm EMT UNLESS OTHERWISE SHOWN. EMT 12mm EMT 20mm SYSTEMS/MODULAR WORKSTATION NOTES

MAG-LOCK PROXIMITY FOB (NIC) 5R8 V2L 5. REFER TO ELECTRICAL PLAN DRAWING FOR DEVICE LOCATIONS. POWER BY OTHERS ON NON-SECURE SIDE CROSS-CONNECT DATA CABLE TO 1. WHERE SYSTEMS/MODULAR FURNITURE IS USED (REFER TO ARCHITECTURAL 6. ALL JUNCTION BOXES SHALL BE ON THE SECURE SIDE IN THE ACCESSIBLE CEILING SPACE. LABELLED DATA JACKS DEVICES SUPPLIED BY OTHERS AND DRAWINGS FOR LOCATIONS), THE CONTRACTOR SHALL PROVIDE POWER TO IF NO ACCESSIBLE CEILING SPACE, MOUNT JUNCTION BOXES ABOVE DOOR CENTERED AND RUN IN FURNITURE CHASE THE NEAREST WALL AND TERMINATE FURNITURE WHIPS BY METHOD OF HARD PRINCE GEORGE, B.C. PRINCE GEORGE, 177 VICTORIA STREET 177 ALIGNED WITH EACH OTHER AND PROVIDE STAINLESS STEEL COVERPLATES. WIRING. - 200 7. RACEWAY SYSTEM TO BE CONCEALED WHERE POSSIBLE. WHERE CONCEALMENT IS NOT 2. ELECTRICAL CONTRACTOR TO BALANCE AND DISTRIBUTE THE ELECTRICAL STUB INTO FRAME FOR DOOR POSSIBLE, PROVIDE A SURFACE MOUNTED RACEWAY SYSTEM ON THE SECURE SIDE. LOADS OF WORKSTATION PODS EVENLY AMONGST CIRCUITS (EX. POD OF 6 RELEASE WHERE SHOWN VDM 2100 MOUNTED IN WORKSTATIONS, 2 DEDICATED CIRCUITS, 3 PODS CONNECTED TO EACH 8. PROVIDE FIRE GRADE PLYWOOD BACKING AND ROCKETFISH FULL MOTION TV WALL SYSTEMS/MODULAR CIRCUIT). MOUNTS SIZED APPROPRIATELY FOR THE TVS. DATA CABLES TO WORKSTATION 1400mm LAN ROOM ACCESS PANELS DATA 9. CONTRACTOR TO INSTALL ACCESS POINTS DEVICES SUPPLIED BY FNHA AND SECURE TO 1. WHERE SYSTEMS/MODULAR FURNITURE IS USED (REFER TO ARCHITECTURAL FIRST NATIONS NATIONS HEALTH FIRST AUTHORITY Project Drawing FNHA PRINCE GEORGEOFFICE PRINCE FNHA RENO. CEILING. DRAWINGS FOR LOCATIONS), THE CONTRACTOR SHALL PROVIDE AND INSTALL RENOVATION PLAN ELECTRICAL USING COMPATIBLE VOICE DATA MODULES (VDM 2100) AND TERMINATE WORKSTATION DATA OUTLETS WITH THE VDM. 3 ACCESS CONTROL SINGLE DOOR 4 WORKSTATION VDM DETAIL 2. VDM CAN BE FOUND WITHIN THE SYSTEMS/MODULAR FURNITURE ACCESS E-200 NTS E-200 NTS PANELS OR WILL BE PROVIDED BY FNHA. Sheet Number Sheet Project Number Project K000293A E-200

PRINTED: 11/15/2018 2:50:13 PM PRINTED: 11/15/2018 2:50:13 PM

Project Number Project Scale K000293A FNHA PRINCE GEORGE OFFICE NTS Issued For Date 10/05/18 Copyright Reserved

RENO. 200 -177 VICTORIA STREET Date This plan and design are the exclusive property of FIRST NATIONS HEALTH PRINCE GEORGE, B.C. 2018 -11 -01 200, 1628 Dickson Avenue Revisions Thinkspace Architecture, Planning, Interior Design AUTHORITY V2L 5R8 Kelowna BC V1Y 9X1 No. Date Description (Thinkspace) and cannot be used or reproduced without Phone: (250) 860-2257 Sheet Number Drawing 1 2018-10-05 ISSUED FOR COORDINATION written consent of Thinkspace . This office shall be informed Fax: (250) 860-2523 of any variations from the information shown on this SCHEDULES www.cima.ca 2 2018-11-01 ISSUED FOR 95% REVIEW 3 2018-11-09 ISSUED FOR BUILDING PERMIT drawing. Do not scale drawings. 4 2018-11-15 ISSUED FOR BID E-300 Thinkspace , a partnership of: Ron Hoffart, Architect AIBC Mark Mathiasen, Architect AIBC Todd Dust, Architect AIBC Henk Kampman, Architect AIBC t AIBC t

ect AIBC ect . This office. This shall informed be Thinkspace

PANEL 2C-1 (CCT 1-42) SECOND FLOOR ELECTRICAL ROOM PANEL 2C-2 (CCT 43-84) SECOND FLOOR ELECTRICAL ROOM PANEL A SERVER ROOM 271 CopyrightReserved NAMEPLATE LOCATION NAMEPLATE LOCATION NAMEPLATE LOCATION without used be reproduced or cannot and CUTLER-HAMMER POW-R-LINE C PRL1 CUTLER-HAMMER POW-R-LINE C PRL1 SQUARE D QBL 442 a , partnership of: VOLTAGE 120/208 VAC TYPE VOLTAGE 120/208 VAC TYPE VOLTAGE 120/208 VAC TYPE BUS AMPACITY 225 AMPS BUS AMPACITY 225 AMPS BUS AMPACITY 225 AMPS This plan and designand plan areThis the exclusive property of Thinkspace Architecture, Planning, Interior Design (Thinkspace) Thinkspace written consent of consent written Ron Hoffart,Ron AIBC Architect Mark Archit Mathiasen, Dust, AIBC Architect Architec Todd Henk Kampman, CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT. CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT. CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT. this on of any shown variations from the information Doscaledrawing. drawings. not IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN ON THE DRAWING THE CONTRACTOR SHALL MAKE ON THE DRAWING THE CONTRACTOR SHALL MAKE ON THE DRAWING THE CONTRACTOR SHALL MAKE

T ADJUSTMENTS TO SUIT THE INTENT OF THE WORK. ADJUSTMENTS TO SUIT THE INTENT OF THE WORK. ADJUSTMENTS TO SUIT THE INTENT OF THE WORK. I

N

M

O R

I

E

T

W

P

A

E

I

CCT. CCT. CCT. CCT. CCT. CCT. 10/03/18

G

N

I

V

LOAD BRKR BRKR LOAD LOAD BRKR BRKR LOAD LOAD BRKR BRKR LOAD N

E

I

D

No. No. No. No. No. No. R

R D

L

O

I

%

D Date

U I

O

5

C B B

9 1 RECEPTACLES #220 1P-15A 1P-15A VAV 27-2 & 28-2 2 43 RECEPTACLES #200 1P-15A 1P-15A PLUGS ABOVE T-BAR #250 44 1 2P 1P-15A RECEPTACLES IN #260 2

R R R R

KITCHEN RECEPTACLES O O O O

F F F F 3 PHOTOCOPIER RECEPTACLE #220 1P-15A 1P-15A VAV 25-2 & 26-2 & 32-2 4 45 RECEPTACLES #200 1P-15A 1P-15A PLUGS ABOVE T-BAR #250 46 3 15A 1P-15A KITCHEN GFI 4

D D D D

E E E E

U U U U

5 RECEPTACLES #230 1P-15A 1P-15A VAV 23-2 & 24-2 & 31-2 6 47 RECEPTACLES #200 & 220 1P-15A 1P-15A PLUGS ABOVE T-BAR #250 48 5 EXHAUST FANS 1P-15A 1P-15A RECEPTACLES IN #260 6 S S S S

S S S S

I I I I 7 RECEPTACLES #230 1P-15A 1P-15A VAV 21-2 & 22-2 8 49 RECEPTACLES #220 & 230 1P-15A 1P-15A HWT #250 50 7 CCT COMP ROOM GFI RECEPTACLES 1P-15A 1P-15A RECEPTACLES IN #260 8

5 1 9 5

0 0 0 1

- - - -

9 1P-15A 1P-15A 10 51 1P-15A 1P-15A 52 9 1P-20A 1P-15A 10 0 1 1 1

RECEPTACLES #230 VAV 19-2 & 20-2 & 29 30-2 RECEPTACLES #250 BLANK CCT COMP ROOM GFI RECEPTACLES SPARE 1 1 1 1

- - - -

8 8 8 8

1 1 1 1

11 PHOTOCOPIER & RECEPTACLES #230 1P-15A 1P-15A VAV 17-2 & 18-2 12 53 RECEPTACLES #250 AND MICROWAVE 1P-15A 1P-15A PLUGS ABOVE T-BAR #250 54 11 RECEPTACLES IN #260 1P-15A 1P-15A CCT 12 0 0 0 0 Date Description

2 2 2 2

13 LAN ROOM #250 1P-15A 1P-15A DDC CONTROLS WEST 14 55 RECEPTACLES #260 1P-15A 1P-15A PLUGS ABOVE T-BAR #250 56 13 RECEPTACLES IN #260 1P-20A 1P-15A CCT 14 Issued For Revisions No.

1 2 3 4 15 LAN ROOM #260 1P-15A 1P-15A DDC CONTROLS NORTH 16 57 RECEPTACLES #270 1P-15A 1P-15A PLUGS ABOVE T-BAR #250 58 15 RECEPTACLES IN #260 1P-20A 1P-15A RECEPTACLES IN #260 16 17 HWT #260 1P-15A 1P-15A DDC CONTROLS EAST 18 59 RECEPTACLES #200 1P-15A 1P-15A PLUGS ABOVE T-BAR #250 60 17 COMP ROOM RECEPTACLES 1P-30A 1P-15A RECEPTACLES IN #260 18 19 RECEPTACLES #250 & 260 1P-15A 1P-15A DDC CONTROLS SOUTH 20 61 RECEPTACLES #200 EAST CORNER 1P-15A 1P-15A RECEPTACLES #200 62 19 RECEPTACLES - OPEN OFFICE #207 1P-15A 1P-15A EF-1 BOARDROOM EXHAUST 20 21 RECEPTACLES #250 & 260 1P-15A 1P-15A RECEPTACLES #200 22 63 RECEPTACLES #200 & 220 1P-15A 1P-15A RECEPTACLES #200 64 21 FRIDGE RECEPTACLE - KITCHEN #208 1P-15A 2P 22 TEL ROOM 205 A/C 23 RECEPTACLES #260 1P-15A 1P-15A RECEPTACLES #200 24 65 RECEPTACLES #230 1P-15A 1P-15A RECEPTACLES #200 66 23 COUNTER RECEPTACLES - KITCHEN #208 1P-20A 15A 24 25 RECEPTACLES #260 1P-15A 1P-15A RECEPTACLES #200 26 67 RECEPTACLES #230 1P-15A 1P-15A RECEPTACLES #200 68 25 MICROWAVE RECEPTACLE - KITCHEN #208 1P-15A 2P 26 BOARDROOM 221 A/C 27 RECEPTACLES #260 1P-15A 1P-15A RECEPTACLES #250 28 69 KITCHEN COUNTER RECEPTACLE #230 1P-15A 1P-15A RECEPTACLES #200 70 27 DISHWASHER - KITCHEN #208 1P-15A 15A 28 200, 1628 Dickson Avenue Kelowna V1Y BC 9X1 Phone: (250) 860-2257 Fax: (250) 860-2523 www.cima.ca 29 RECEPTACLES #260 1P-15A 1P-15A RECEPTACLES #250 30 71 RECEPTACLES #230 1P-15A 1P-15A HWT #220 & 200 72 29 COPIER RECEPTACLE - COPY #210 1P-20A 1P-15A SPARE 30

31 RECEPTACLES #200 1P-15A 1P-15A RECEPTACLES #250 32 73 MICROWAVE COUNTER RECEPTACLE #230 1P-15A 3P 74 31 RECEPTACLE - OFFICE #211 1P-15A 1P-15A SPARE 32 33 RECEPTACLES #200 1P-15A 1P-15A RECEPTACLES #250 34 75 SERVER RECEPTACLE #230 1P-15A SUB PANEL A ROOM #260 76 33 RECEPTACLES - OPEN OFFICE #224 1P-15A 1P-15A SPARE 34 60A 35 RECEPTACLES #200 1P-15A 1P-15A RECEPTACLES #250 36 77 WASHROOMS GFI RECEPTACLES 1P-15A 78 35 FLOOR RECEPTACLES - BOARDROOM #221 1P-15A 1P-15A SPARE 36

37 RECEPTACLES #200 & FRIDGE 1P-15A 1P-15A RECEPTACLES #250 FOR FRIDGE 38 79 JANITOR & ELECTRICAL ROOM RECEPTACLES 1P-15A 3P 80 37 RECEPTACLES - RECEPTION 1P-15A BLANK 38 SUB PANEL 2CA ELECTRICAL ROOM 2ND 39 MICROWAVE #200 1P-15A 1P-15A COUNTER PLUG #250 KITCHEN 40 81 TEL CLOSET RECEPTACLES 1P-15A 82 39 BLANK BLANK 40 FLOOR 70A 41 #200 KITCHEN COUNTER RECEPTACLE 1P-20A 1P-15A RECEPTACLES #250 42 83 WASHROOM ENTRANCE RECEPTACLES 1P-15A 84 41 ACCESS DOOR LOCKS 1P-15A BLANK 42

CROSSED OUT CIRCUITS ARE REMOVED AND RE-USED. REFER TO PLAN DRAWINGS FOR RE-USED CIRCUITS. REMOVE EXISTING WIRING TO CIRCUIT AND PROVIDE NEW. FED FROM PANEL 2C CCT 74-76-78

PANEL 2C HAS TWO CABINETS SIDE-BY-SIDE. 1 PANEL 2C - EXISTING 2 PANEL A E-301 NTS E-301 NTS

GENERAL NOTES

1. CONFIRM EXISTING AND RE-PURPOSED CIRCUITS AND PROVIDE NEW TYPEWRITTEN PANELBOARD SCHEDULES FOR ALL PANELBOARDS. UPDATE LABELS TO NEW ROOM NUMBERING.

NAMEPLATE PANEL 2C-1 (CCT 1-42) LOCATION SECOND FLOOR ELECTRICAL ROOM NAMEPLATE PANEL 6C LOCATION SECOND FLOOR ELECTRICAL ROOM NAMEPLATE PANEL 2CA LOCATION SECOND FLOOR ELECTRICAL ROOM CUTLER-HAMMER POW-R-LINE C PRL1 CUTLER-HAMMER POW-R-LINE C PRL2 CUTLER-HAMMER POW-R-LINE C PRL1 VOLTAGE 120/208 VAC TYPE VOLTAGE 347/600 VAC TYPE VOLTAGE 120/208 VAC TYPE BUS AMPACITY 225 AMPS BUS AMPACITY AMPS BUS AMPACITY 225 AMPS CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT. CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT. CONTRACTOR TO VERIFY CIRCUITS SHOWN ARE CORRECT. IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN IF AS FOUND CONDITIONS DIFFER FROM THOSE SHOWN ON THE DRAWING THE CONTRACTOR SHALL MAKE ON THE DRAWING THE CONTRACTOR SHALL MAKE ON THE DRAWING THE CONTRACTOR SHALL MAKE ADJUSTMENTS TO SUIT THE INTENT OF THE WORK. ADJUSTMENTS TO SUIT THE INTENT OF THE WORK. ADJUSTMENTS TO SUIT THE INTENT OF THE WORK.

CCT. CCT. CCT. CCT. CCT. CCT. LOAD BRKR BRKR LOAD LOAD BRKR BRKR LOAD LOAD BRKR BRKR LOAD No. No. No. No. No. No.

1 RECEPTACLES #220 1P-15A 1P-15A VAV 27-2 & 28-2 2 1 3RD FLOOR OFFICE LIGHTS 1P-15A 1P-15A 2ND FLOOR OFFICE LIGHTS 2 1 LAB RECEPTACLES #220 1P-15A 2P 2 LAB PLUGS #220 3 PHOTOCOPIER RECEPTACLE #220 1P-15A 1P-15A VAV 25-2 & 26-2 & 32-2 4 3 3RD FLOOR OFFICE LIGHTS 1P-15A 1P-15A 2ND & 3RD FLOOR EMERG & NIGHT LIGHTS 4 3 LAB RECEPTACLES #220 1P-15A 20A 4 5 RECEPTACLES #230 1P-15A 1P-15A VAV 23-2 & 24-2 & 31-2 6 5 3RD FLOOR OFFICE LIGHTS 1P-15A 1P-15A 2ND FLOOR CMHC OFFICE LIGHTS 6 5 LAB RECEPTACLES #220 1P-15A 1P-15A LAB RECEPTACLES #220 6 7 RECEPTACLES #230 1P-15A 1P-15A VAV 21-2 & 22-2 8 7 3RD FLOOR OFFICE LIGHTS 1P-15A 1P-15A 2ND FLOOR OFFICE LIGHTS 8 7 LAB RECEPTACLES #220 1P-15A 1P-15A LAB RECEPTACLES #220 8 9 RECEPTACLES #230 1P-15A 1P-15A VAV 19-2 & 20-2 & 29 30-2 10 9 3RD FLOOR OFFICE LIGHTS 1P-15A 1P-15A 2ND FLOOR OFFICE LIGHTS 10 9 LAB RECEPTACLES #220 1P-15A 1P-15A LAB RECEPTACLES #220 10 11 PHOTOCOPIER & RECEPTACLES #230 1P-15A 1P-15A VAV 17-2 & 18-2 12 11 3RD FLOOR OFFICE LIGHTS 1P-15A 1P-15A 2ND FLOOR OFFICE LIGHTS 12 11 LAB RECEPTACLES #220 1P-15A 1P-15A LAB RECEPTACLES #220 12 13 FRIDGE RECEPTACLES - BOARDROOM #221 1P-15A 1P-15A DDC CONTROLS WEST 14 13 3RD FLOOR OFFICE LIGHTS 1P-15A 1P-15A 2ND & 3RD FLOOR LOBBY LIGHTS 14 13 LAB RECEPTACLES #200 1P-15A 1P-15A LAB RECEPTACLES #220 14 15 COUNTER RECEPTACLES - BOARDROOM #221 1P-20A 1P-15A DDC CONTROLS NORTH 16 15 3RD FLOOR OFFICE LIGHTS 1P-15A 1P-15A 2ND & 3RD FLOOR WASHROOM LIGHTS 16 15 LAN RECEPTACLES #200 1P-15A 1P-15A LAB RECEPTACLES #220 16 17 HWT #260 1P-15A 1P-15A DDC CONTROLS EAST 18 17 3RD FLOOR OFFICE LIGHTS 1P-15A 1P-15A 18 17 LAN RECEPTACLES #200 1P-15A 1P-15A HEALTH CANADA DISHWASHER #200 18 19 CONV. RECEPTACLES 1P-15A 1P-15A DDC CONTROLS SOUTH 20 19 BLANK BLANK 20 19 LAN RECEPTACLES #200 1P-15A 1P-15A POT LIGHTS MEETING RM #200 20 21 OFFICE RECEPTACLES - IT #225 & OPEN #224 1P-15A 1P-15A RECEPTACLES #200 22 21 BLANK BLANK 22 21 LAN RECEPTACLES #200 1P-15A 1P-15A FRIDGE & WATER COOLER IN #200 22 23 RECEPTACLES #260 1P-15A 1P-15A RECEPTACLES #200 24 23 BLANK BLANK 24 23 LAN RECEPTACLES #200 1P-15A 1P-15A RECEPTACLES #270 24 25 RECEPTACLES #260 1P-15A 1P-15A RECEPTACLES #200 26 25 BLANK BLANK 26 25 EXHAUST FAN LAB #220 1P-15A 1P-15A RECEPTACLES #270 26 01

27 RECEPTACLES #260 1P-15A 1P-15A OFFICE RECEPTACLES 28 27 BLANK BLANK 28 27 2P 1P-15A RECEPTACLES #270 28 - 11

A/C LAN ROOM #200 - 29 RECEPTACLES #260 1P-15A 1P-15A OFFICE RECEPTACLES 30 29 BLANK BLANK 30 29 20A 1P-15A RECEPTACLES #270 30 31 RECEPTACLES #200 1P-15A 1P-15A RECEPTACLES #250 32 31 BLANK BLANK 32 31 RECEPTACLES #260 1P-15A 1P-15A RECEPTACLES #270 32 Scale NTS Date 2018 33 RECEPTACLES #200 1P-15A 1P-15A CONV. RECEPTACLES 34 33 BLANK BLANK 34 33 RECEPTACLES #260 1P-15A 1P-15A RECEPTACLES #270 34 V2L 5R8 V2L 35 RECEPTACLES #200 1P-15A 1P-15A SWITCHED RECEPTACLES 36 35 BLANK BLANK 36 35 RECEPTACLES #260 1P-15A 1P-15A RECEPTACLES #270 36 37 RECEPTACLES #200 & FRIDGE 1P-15A 1P-15A SWITCHED RECEPTACLES 38 37 BLANK BLANK 38 37 3P 1P-15A RECEPTACLES #270 38 39 MICROWAVE #200 1P-15A 1P-15A SWITCHED RECEPTACLES 40 39 BLANK BLANK 40 39 PLUGS IN HEALTH CANADA (AUTOCLAVE) 1P-15A RECEPTACLES #270 40 PRINCE GEORGE, B.C. PRINCE GEORGE, 177 VICTORIA STREET 177 - 41 #200 KITCHEN COUNTER RECEPTACLE 1P-20A 1P-15A SWITCHED RECEPTACLES 42 41 BLANK 1P-15A EXIT LIGHTS 42 41 40A 1P-20A PHOTOCOPIER #200 42 200

3 PANEL 2C - REVISED 4 PANEL 6C - EXISTING 5 PANEL 2CA - EXISTING E-301 NTS E-301 NTS E-301 NTS FIRST NATIONS NATIONS HEALTH FIRST AUTHORITY Project Drawing FNHA PRINCE GEORGEOFFICE PRINCE FNHA RENO. SCHEDULES Sheet Number Sheet Project Number Project K000293A E-301

PRINTED: 11/15/2018 2:50:14 PM t AIBC t

ect AIBC ect

PART 1 - GENERAL PART 8 - RECORD DRAWINGS .5 FIRE ALARM BELL/STROBES: NO LESS THAN 2000MM (79 IN.) AND NO MORE THAN 2400MM (95IN.) 26.9 SYSTEM TO INCLUDE BATTERY BANK AND CHARGER WITH SUFFICIENT CAPACITY TO OPERATE 1.1 THE GENERAL CONDITIONS AND INSTRUCTIONS TO BIDDERS AS SET FORTH IN THE GENERAL 8.1 OBTAIN A WHITE SET OF PRINTS TO BE USED TO RECORD WORK AS INSTALLED. RECORD IN .6 COUNTER-TOP OUTLETS: 1120MM (44 IN.) SYSTEM UNDER SUPERVISORY LOAD CONDITIONS WITHOUT RECHARGING FOR 12 CONSECUTIVE CONTRACT SPECIFICATIONS AND ALL ADDENDA THERETO SHALL APPLY TO, AND GOVERN ALL COLOURED PENCIL ALL CHANGES, ALTERATIONS OR ADDITIONS THAT OCCUR DURING THE PART 16 - IDENTIFICATION HOURS. PORTIONS OF THE ELECTRICAL WORK. PROGRESS OF WORK; INCLUDING ALL CHANGES TO THE ORIGINAL TENDER DRAWINGS COVERED BY 16.1 LABEL ALL PANELS, STARTERS, DISTRIBUTION CENTRES, LIGHTING CONTROLS, TRANSFORMERS 26.10 REQUEST TO EXIT PUSH BUTTON TO BE MOUNTED AT 1524MM A.F.F. . This office. This shall informed be 1.2 POINTS NOT SPECIFICALLY MENTIONED SHALL BE IN STRICT ACCORDANCE WITH THE CURRENT ADDENDA, CHANGE ORDERS, FIELD CHANGES, JOB CONDITIONS, ETC. WITH 13MM LAMICOID PLATES, PERMANENTLY ATTACHED TO THE EQUIPMENT. 26.11 INTEGRATION WITH INTRUSION ALARM SYSTEM MAY BE ACCOMPLISHED BY CONNECTING VERSION OF THE CANADIAN ELECTRICAL CODE AND REGULATIONS OF THE ELECTRICAL INSPECTION 8.2 AT THE CONCLUSION OF THE JOB, FORWARD THE MARKED UP DRAWINGS TO THE ENGINEER FOR 16.2 PROVIDE ADHESIVE LABELS FOR RECEPTACLE CIRCUIT NUMBERS AND VOICE/DATA JACK INTRUSION ALARM PANEL WITH DOOR CONTROLLER. ACCESS CONTROL SOFTWARE SHOULD BE DEPARTMENT FROM WHICH THE PERMIT WAS OBTAINED. UPDATING THE ORIGINAL DOCUMENTS. ALLOW $1,000 PLUS GST, WHERE APPLICABLE, IN BID PRICE IDENTIFICATION. CAPABLE OF RECEIVING INTRUSION EVENTS, VIEW STATUS OF ZONES AND PARTITIONS, AND 1.3 WHERE THE TERMS "FURNISH", "PROVIDE" OR "INSTALL" APPEAR IN THIS DIVISION, OR A TO COVER THIS WORK. PROGRAM USER CODES. SYSTEM MAY BE ARMED/DISARMED VIA A CARD READER OR MANUALLY VIA Thinkspace PART 17 - DISCONNECT SWITCHES THE WORKSTATION SOFTWARE. CopyrightReserved

MANUFACTURER IS INDICATED WITH ITEM OR PRODUCT CATALOG NUMBER LISTED, IT IS THE PART 9 - OPERATION & MAINTENANCE MANUALS without used be reproduced or cannot and

17.1 DISCONNECT SWITCHES SHALL BE EQUAL TO EATON DH1 SERIES, WEATHERPROOF WHERE NOTED. a , partnership of: CONTRACTOR'S RESPONSIBILITY TO FURNISH AND INSTALL THE ITEM COMPLETE AND OPERATING 9.1 BEFORE COMPLETION AND ACCEPTANCE OF THE PROJECT, SUBMIT AN ELECTRICAL SYSTEM PART 27 - SECURITY - NETWORK VIDEO SURVEILLANCE (NVS) FOR THE PURPOSE OR FUNCTION INTENDED, UNLESS OTHERWISE NOTED. OPERATION & MAINTENANCE MANUAL IN 2" (MINIMUM) D-RING BLACK BINDERS. MANUALS SHALL PART 18 - MOTOR STARTERS 27.1 PROVIDE A COMPLETE NETWORK VIDEO SURVEILLANCE (NVS) SYSTEM TO BE INSTALLED, PART 2 - CODES, PERMITS AND INSPECTIONS INCLUDE TECHNICAL DATA OF EACH PIECE OF EQUIPMENT AS WELL AS TESTS AND OPERATION AND 18.1 MANUAL MOTOR STARTERS EQUAL TO EATON B100 SERIES. CONNECTED, TESTED, AND LEFT IN FIRST-CLASS OPERATING CONDITION. This plan and designand plan areThis the exclusive property of Thinkspace Architecture, Planning, Interior Design (Thinkspace) Thinkspace written consent of consent written Ron Hoffart,Ron AIBC Architect Mark Archit Mathiasen, Dust, AIBC Architect Architec Todd Henk Kampman, 2.1 THE INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE CURRENT EDITION OF THE MAINTENANCE REQUIREMENTS NOT READILY APPARENT TO AN UNSKILLED USER OR AS 18.2 MAGNETIC MOTOR STARTERS SHALL BE EQUAL TO EATON A200 SERIES WITH HOA CONTROLS AND 27.2 THE NVS SYSTEM IS COMPRISED OF SEVERAL COMPATIBLE, CSA APPROVED COMPONENTS. IN this on of any shown variations from the information Doscaledrawing. drawings. not CANADIAN ELECTRICAL CODE (AS AMENDED BY THE AUTHORITY HAVING JURISDICTION), LOCAL REQUESTED BY THE OWNER'S REPRESENTATIVE. PROVIDE MANUAL AND SEMINAR WITH OWNER'S AUXILIARY CONTACTS. GENERAL, THE SYSTEM INCLUDES FIXED DOME NETWORK CAMERAS, NETWORK VIDEO RECORDER, BUILDING CODE AND THE REGULATIONS OF THE ELECTRICAL INSPECTION DEPARTMENT HAVING FORCES TO ENSURE PROPER OPERATION OF BUILDING PRIOR TO SUBSTANTIAL COMPLETION. LCD MONITOR, CAMERA BRACKETS, CABLES, AND INSTALLATION HARDWARE. PART 19 - MECHANICAL AND OTHER EQUIPMENT T PROVIDE A COVER PAGE ON THE BINDER FRONT AND SLEEVE. PROVIDE A PROJECT TEAM CONTACT I

N JURISDICTION. 27.3 THE NVS SYSTEM WILL CONTINUOUSLY MONITOR ALL CAMERA POSITIONS IN SEQUENCE M

O R

19.1 PROVIDE WIRING, CONNECTIONS, STARTERS, DISCONNECTS AND CONTROLS FOR ALL MECHANICAL, I

LIST, TABLE OF CONTENTS AND LABELLED SECTION DIVIDERS. ALLOW FOR THREE HARD COPIES E

T

W

P

2.2 THE ELECTRICAL TRADE SHALL OBTAIN ALL ELECTRICAL PERMITS REQUIRED AND, AFTER DETERMINED BY AN ADJUSTABLE DWELL TIME, AND DISPLAY THE VIDEO IMAGE ON THE PROVIDED

A

E

OWNER AND OTHER TRADE INSTALLED EQUIPMENT. I AND AN ELECTRONIC PDF IN THE BASE BID. 10/03/18 G

N

I

V

COMPLETION OF THE WORK, SHALL FURNISH TO THE ENGINEER A CERTIFICATE OF FINAL MONITOR. N

E

I

D

R

19.2 PROVIDE FLEXIBLE CONNECTIONS AND VIBRATION ISOLATION TO ALL MECHANICAL EQUIPMENT. R D PART 10 - CHANGES TO WORK

INSPECTION AND APPROVAL FROM THE INSPECTION DEPARTMENT. L

O

I

27.4 NETWORK VIDEO RECORDER: PANASONIC WJ-NV200 OR APPROVED EQUAL. %

D Date

U I

O ALL CONNECTIONS TO EQUIPMENT IN WET LOCATIONS SHALL BE LIQUID-TIGHT. 5

C B B 10.1 ANY CHANGES TO THE CONTRACT DOCUMENTS REQUIRES A CONTEMPLATED CHANGE NOTICE 9 2.3 FEES FOR ALL PERMITS AND LICENSES REQUIRED FOR THE WORK SHALL BE INCLUDED BY THE 19.3 CONTROL WIRING TO BE BY THE MECHANICAL CONTRACTOR. WHERE LINE VOLTAGE POWER IS 27.5 NETWORK FIXED DOME CAMERA (INTERIOR): PANASONIC WV-SFR310A OR APPROVED EQUAL. R R R R ELECTRICAL CONTRACTOR. PRODUCED BY THE CONSULTANT AND ISSUED AS A CHANGE ORDER BY THE COORDINATING O O O O

F F F F REQUIRED FOR MECHANICAL EQUIPMENT, THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE PROVIDE WIDE-ANGLE LENS WHERE NOTED. PROFESSIONAL PRIOR TO ANY RELATED WORK COMMENCING. D D D D

PART 3 - STANDARD OF ACCEPTANCE E E E E

CONNECTION. 27.6 MONITOR: PANASONIC PLCD24HDA 24" LCD DISPLAY OR APPROVED EQUAL. U U U U

10.2 QUOTES SUBMITTED BY THE CONTRACTOR MUST COME COMPLETE WITH AN ITEMIZED S S S S

S S S S 3.1 ALL MATERIALS SHALL BE NEW AND OF THE QUALITY SPECIFIED UNLESS SPECIFICALLY SHOWN AS I I I I BREAKDOWN OF MATERIAL AND LABOUR COSTS. QUANTITIES MUST BE CLEARLY DEFINED IN EITHER PART 20 - ELECTRIC HEAT 27.7 SOFTWARE: PANASONIC WV-ASM200W RECORDING MANAGEMENT SOFTWARE OR APPROVED EQUAL. EXISTING TO BE RE-USED IN THE CONTRACT DOCUMENTS. NEW MATERIALS SHALL CONFORM TO METRIC OR IMPERIAL UNIT MEASUREMENTS. MATERIAL UNIT COSTS MUST BE CLEARLY DEFINED AS 5 1 9 5 20.1 BASEBOARD HEATERS SHALL BE EQUAL TO OUELLET OFM SERIES 208 VOLT, SINGLE PHASE, PART 28 - SEISMIC PROTECTION 0 0 0 1 THE STANDARDS OF THE CSA AND THE ULC AND APPROVED BY THESE AGENCIES, WHERE - - - - A COST PER UNIT OF MEASUREMENT (IE. $/FT). LABOUR UNIT COSTS MUST BE DEFINED AS A COST 0 1 1 1 COMPLETE WITH BUILT-IN THERMOSTATS AS NOTED. 1 1 1 1 APPLICABLE. FOR ANY MATERIAL NOT CSA APPROVED, THE CONTRACTOR SHALL OBTAIN THE 28.1 THE ELECTRICAL CONTRACTOR SHALL PROVIDE SEISMIC RESTRAINT AND ANCHORAGE FOR ALL - - - - PER UNIT OF TIME (IE. $/H). 8 8 8 8

1 1 1 1

APPROVAL OF THE LOCAL INSPECTION AUTHORITY AND SHALL BEAR ALL INSPECTION CHARGES 20.2 FORCE FLOW HEATERS SHALL BE EQUAL TO OUELLET OAC SERIES 208 VOLT, SINGLE PHASE, ELECTRICAL EQUIPMENT AND SERVICES IN ACCORDANCE WITH THE CURRENT EDITION OF THE BC 0 0 0 0 Date Description LEVIED AND ANY MODIFICATION COSTS REQUIRED. 10.3 ANY ENGINEERING DESIGN, REVIEW, APPROVAL AND SITE INSPECTIONS REQUIRED BY PROPOSED COMPLETE WITH BUILT-IN THERMOSTATS AS NOTED. BUILDING CODE AND ALL APPLICABLE BUILDING BYLAWS. 2 2 2 2 Issued Issued For Revisions No. CHANGES MADE BY THE CONTRACTOR, GC OR OTHER SUB-CONTRACTOR SHALL BE PAID DIRECTLY 1 2 3 4 3.2 ALL PHASES OF THE ELECTRICAL INSTALLATION SHALL BE EXECUTED IN A SATISFACTORY, 20.3 CEILING MOUNTED FORCE FLOW HEATERS SHALL BE EQUAL TO OUELLET OACP SERIES 208 VOLT, 28.2 INCLUDE IN THE TENDERED PRICE ALL SERVICES OF A REGISTERED PROFESSIONAL IN THE FIELD TO THE CONSULTANT BY THE CONTRACTOR, GC OR OTHER SUB-CONTRACTOR PROPOSING THE WORKMANLIKE MANNER AND SHALL PRESENT A NEAT APPEARANCE WHEN COMPLETED. WORK NOT SINGLE PHASE, COMPLETE WITH REMOTE MOUNTED THERMOSTAT AND T-BAR CEILING ADAPTER. OF SEISMIC RESTRAINT TO PROVIDE SUPPLEMENTAL SCHEDULE S LETTERS OF ASSURANCE IN CHANGES AT A RATE OF $150/HR PLUS EXPENSES. NO ENGINEERING WORK WILL PROCEED DEEMED SATISFACTORY TO THE ENGINEER SHALL BE CORRECTED AT THE CONTRACTOR'S RESPECT OF THE SEISMIC RESTRAINT OF ALL ELECTRICAL MATERIALS AND EQUIPMENT, WITHOUT A SIGNED PURCHASE ORDER TO THE CONSULTANT FROM THE APPLICABLE CONTRACTOR. 20.4 KICKSPACE FAN HEATERS SHALL BE EQUAL TO OUELLET OCP SERIES 208 VOLT, SINGLE PHASE, EXPENSE. COMPETE WITH BUILT-IN HEATER. CONDUCTING THE NECESSARY SITE REVIEWS AND PROVIDING A LETTER AT THE CONCLUSION OF PART 11 - TESTING THE PROJECT CONFIRMING THAT ALL SEISMIC RESTRAINTS FOR THE ELECTRICAL WORKS HAVE PART 4 - SETTING OUT THE WORK 20.5 UNIT HEATERS SHALL BE EQUAL TO OUELLET OAS SERIES 208 VOLT, SINGLE PHASE, COMPLETE 11.1 PERFORM MEGGER TESTS ON ALL FEEDERS TO ENSURE THAT THE C.E.C. REQUIREMENTS ARE MET. BEEN INSTALLED IN ACCORDANCE WITH THE ENGINEER'S INSTRUCTIONS. SUPPLEMENTAL 4.1 ELECTRICAL WORK IS TO BE CARRIED OUT BY QUALIFIED, LICENSED ELECTRICIANS WHO HOLD A WITH REMOTE THERMOSTAT. TAKE CURRENT READINGS ON ALL FEEDERS AND IF LOAD UNBALANCE EXCEEDS 15%, RECONNECT SCHEDULES TO BE SUBMITTED TO THE ELECTRICAL ENGINEER OF RECORD. VALID PROVINCIAL LICENSE IN ACCORDANCE WITH THE AHJ. LOADS TO BRING WITHIN BALANCE. 20.6 PROVIDE AND INSTALL REMOTE THERMOSTATS WHERE SHOWN ON THE DRAWINGS. PART 29 - FIELD REVIEWS 4.2 THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ALL WORK COMPLETED PART 12 - GUARANTEE/WARRANTY PART 21 - TELEPHONE & DATA SYSTEM CONTRARY TO THE INTENT OF THE DRAWINGS AND SPECIFICATIONS AND SHALL BEAR ALL COSTS 29.1 THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CALLING THE ENGINEER, AS REQUIRED BY 21.1 PROVIDE A COMPLETE VOICE AND DATA DISTRIBUTION SYSTEM. COMPLETE SYSTEM TO BE THE LOCAL BUILDING CODE, FOR FIELD REVIEWS AT ROUGH-IN, SUBSTANTIAL COMPLETION AND FOR SAME. WHERE THE INTENT OF THE DRAWINGS AND SPECIFICATIONS ARE NOT CLEAN, THE 12.1 THE ELECTRICAL CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE FOR THE FOLLOWING: 200, 1628 Dickson Avenue Kelowna V1Y BC 9X1 Phone: (250) 860-2257 Fax: (250) 860-2523 www.cima.ca CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITH SUPPLIED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, INCLUDING BUT NOT LIMITED TO: THE COMPLETION OF ANY DEFICIENCIES. .1 ALL WORK EXECUTED UNDER THIS CONTRACT WILL BE FREE FROM DEFECTS OF WORKMANSHIP OUTLETS, CONNECTORS, CABLING, PATCH PANELS, PATCH CABLES, ETC. THE WORK. AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. 29.2 THE ELECTRICAL CONTRACTOR MUST GIVE THE ENGINEER TWO BUSINESS DAYS' NOTICE FOR ALL 21.2 PATCH PANELS, VOICE AND DATA JACKS AND CABLING SHALL BE CAT6 STYLE INSTALLED IN REVIEWS. 4.3 WHERE ANY EQUIPMENT SUPPLIED BY THE ELECTRICAL TRADE MUST BE BUILT-IN WITH WORK OF .2 CONTRACTOR AGREES THAT IT WILL, AT ITS OWN EXPENSE, REPAIR AND REPLACE ALL SUCH EXISTING DATA RACK IN THE LAN ROOM. PROVIDE TYPED LABELS FOR CABLES TERMINATED ON OTHER CONTRACTORS, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEFECTIVE WORK AND OTHER WORK DAMAGED THEREBY WHICH FAILS OR BECOMES 29.3 FAILURE TO INFORM THE ENGINEER OF PROGRESS MAY RESULT IN THE ENGINEER BEING UNABLE PATCH PANELS. SUPPLYING OF THE EQUIPMENT TO BE BUILT-IN OR MEASUREMENTS TO ALLOW NECESSARY DEFECTIVE DURING THE TERM OF THE WARRANTY PERIOD PROVIDED SUCH FAILURE IS NOT A TO ISSUE AN ASSURANCE OF PROFESSIONAL FIELD REVIEW AND COMPLIANCE (SCHEDULE C-B) TO OPENINGS TO BE LEFT SO AS NOT TO HOLD UP THE WORK. RESULT OF IMPROPER USAGE. 21.3 PROVIDE 4" SQUARE BOX, SINGLE GANG PLASTER RING AND 3/4 CONDUIT STUBBED INTO CEILING THE BUILDING AUTHORITY. 4.4 THE ELECTRICAL TRADE, IN SETTING OUT OF HIS WORK, SHALL MAKE REFERENCE TO ALL OTHER .3 THE PERIOD OF THE GUARANTEE SPECIFIED SHALL IN NO WAY SUPPLANT ANY OTHER SPACE AND EXTEND TO CABLE TRAY. DISCIPLINES AND SPECIFICATIONS. THE ELECTRICAL CONTRACTOR SHALL CONSULT WITH THE GUARANTEE OF A LONGER PERIOD, BUT SHALL BE BINDING ON WORK NOT OTHERWISE 21.4 CABLES SHALL BE SUPPORTED AT INTERVALS NO GREATER THAN 5'0" (1524MM). RESPECTIVE TRADES IN SETTING OUT LOCATIONS FOR ALL EQUIPMENT AND WIRING SO THAT COVERED. 21.5 CABLES SHALL NOT BE RUN WITHIN 12" (304MM) OF LIGHTING AND NOT LESS THAN 36" (914MM) CONFLICTS ARE AVOIDED AND SYMMETRICAL SPACING IS MAINTAINED. PART 13 - WIRING METHODS FROM MOTORS, TRANSFORMERS OR OTHER ELECTRICAL EQUIPMENT. 4.5 BEFORE SUBMITTING TENDER, CAREFULLY EXAMINE THE SITE OF THE PROPOSED WORK SO AS TO 13.1 ALL WIRING TO BE COPPER, UNLESS OTHERWISE NOTED. 21.6 CABLES TO BE RUN CONTINUOUSLY, WITH NO SPLICES AND MUST NOT EXCEED A TOTAL LENGTH ASCERTAIN ALL EXISTING CONDITIONS AFFECTING THE WORK. NO EXTRAS WILL BE ALLOWED FOR 13.2 ALL CABLING SHALL BE FT4 RATED EXCEPT IN PLENUM SPACES WHICH SHALL BE FT6 RATED. NOTE OF 90M. WORK NECESSITATED BY CONDITIONS ORDINARILY EVIDENT ON THE SITE. REPORT TO THE THAT THE T-BAR CEILING SPACES FOR THIS PROJECT ARE PLENUM SPACES SO ALL WIRING WITHIN 21.7 PROVIDE 'J' HOOKS FOR CABLE SUPPORT. HOOKS SHALL NOT EXCEED 40% OF THEIR FILL CAPACITY. ENGINEER ANY CONDITIONS THAT MAY AFFECT THE PROPER COMPLETION OF THIS WORK. THAT SPACE SHALL BE FT6. 21.8 ALL CABLES MUST BE BLUE AND MARKED WITH A PERMANENT LABEL ON EACH END AND AT ALL 4.6 WHERE LIGHTING FIXTURES, SPEAKERS, ETC. OCCUR IN ACOUSTIC TILE TYPE CEILING, THE 13.3 FEEDERS SHALL BE SIZED WITH A MAXIMUM OF 2% VOLTAGE DROP. INTERMEDIATE LOCATIONS. FIXTURE OR SPEAKER LOCATION SHALL BE COORDINATED WITH THE TILE PATTERN AND SHALL BE ADJUSTED, IF REQUIRED TO SUIT THE TILE PATTERN. 13.4 BRANCH CIRCUIT WIRING SHALL BE MINIMUM #12 AWG 90C RATED IN EMT OR AC-90 MAY BE USED, 21.9 DATA/VOICE JACKS SHALL BE BLUE WITH WHITE COVERPLATE AND HAVE ADHESIVE LABELS TO WHERE PERMITTED BY CODE. WHERE WIRE SIZES ARE NOT SHOWN, THE AMPACITY MUST MATCH IDENTIFY EACH OUTLET. 4.7 WHERE RECEPTACLES ARE MOUNTED ABOVE COUNTERS, BENCHES, BACKSPLASHES, ETC., OR EXCEED THAT OF THE PROTECTIVE DEVICE. LOCATION AND MOUNTING HEIGHTS SHALL BE COORDINATED WITH THE BUILT-IN UNITS AND 21.10 PROVIDE RECORD DRAWINGS SHOWING LABELLING OF EACH DATA/VOICE JACK TO BE STORED IN ARCHITECTURAL DRAWINGS. 13.5 FLEXIBLE CONDUIT CONNECTIONS TO MOTORS, CONTROL, ETC. TO BE FLEXIBLE PLASTIC TELECOMMUNICATIONS ROOM. JACKETED, SEAL TIGHT OR APPROVED EQUAL. FLEXIBLE CONNECTIONS ARE REQUIRED TO ALL 21.11 ALL CABLES AND TERMINATION HARDWARE SHALL BE 100% TESTED FOR DEFECTS IN INSTALLATION 4.8 MOUNTING HEIGHTS SHALL BE COORDINATED WITH ARCHITECTURAL DETAILS AND SHALL BE MOTORS FROM STUB-UPS OR JUNCTION BOXES. MAXIMUM LENGTH PERMITTED IS 3 FT. ADJUSTED, IF REQUIRED, TO SUIT PANELING, DADOS, MASONRY COURSE LINES, ETC. AND TO VERIFY CABLING SYSTEM PERFORMANCE UNDER INSTALLED CONDITIONS ACCORDING TO 13.6 CONDUIT TO BE SIZED IN ACCORDANCE WITH TABLE 6 OF THE CANADIAN ELECTRICAL CODE. THE REQUIREMENTS OF CSA T568.1, LATEST EDITION. SUBMIT TEST RESULTS OF ALL CABLE 4.9 WHERE OUTLETS OCCUR IN THE WARM SIDE OF PERIMETER WALLS, THE ELECTRICAL CONDUITS TO BE INSTALLED FREE FROM DENTS. CONDUIT ENDS ARE TO BE PLUGGED TO PREVENT TESTING TO THE ENGINEER. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE VAPOUR BARRIER AND ENSURE THERE IS ENTRANCE OF DIRT OR MOISTURE. INSULATION BEHIND THE OUTLET BOXES TO PREVENT CONDENSATION IN THE BOXES. PART 22 - LIGHTING 13.7 ALL PENETRATIONS OF FIRE RATED ASSEMBLIES ARE TO BE SEALED WITH AN APPROVED FIRE 22.1 THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL LUMINAIRES NOTED ON THE 4.10 UPON INSTRUCTION FROM THE ENGINEER, AND PRIOR TO ORIGINAL INSTALLATION, OUTLETS MAY STOP SYSTEM SUCH THAT THE PENETRATED MEMBRANE IS MAINTAINED IN ACCORDANCE WITH THE DRAWINGS, COMPLETE WITH LAMPS, HANGERS, ACCESSORIES, ETC. FOR A COMPLETE AND BE RELOCATED UP TO 3M FROM LOCATION SHOW ON DRAWINGS, AT NO ADDITIONAL COST. LOCAL BUILDING CODE. OPERATIONAL INSTALLATION. 4.11 OUTLETS LOCATED IN PARTY WALLS SHALL NOT BE INSTALLED BACK-TO-BACK, TO PREVENT .1 INSTALL ALL FIRE STOPPING IN ACCORDANCE WITH ULC FIRE RESISTANCE DIRECTORY OR UL 22.2 LUMINAIRES SHALL BE LEFT CLEAN AT COMPLETION OF THE PROJECT WITH ALL LAMPS SOUND TRANSMISSION. PRODUCTS CERTIFIED FOR CANADA (CUL) DIRECTORY. OPERATIONAL. 4.12 INSTALLATION OF CONDUITS, OUTLETS AND EQUIPMENT IN MECHANICAL ROOMS SHALL NOT .2 INSTALL FIRE STOPPING AS PER MANUFACTURER'S RECOMMENDATIONS. PROCEED UNTIL THE INSTALLATION OF MECHANICAL EQUIPMENT HAS PROGRESSED FAR ENOUGH 22.3 SUPPLY AND INSTALL LAMPS IN ALL EXISTING LUMINAIRES TO BE RE-USED. LAMPS SHALL MATCH .3 REFER TO ARCHITECTURAL DRAWINGS FOR RATINGS OF ALL WALLS AND FLOORS. TO AVOID CONFLICTS. EXISTING. 13.8 WIRING SHALL BE INSTALLED CONTINUOUSLY WITHIN RACEWAYS. SPLICING SHALL ONLY BE 22.4 RE-BALLAST ALL EXISTING LUMINAIRES TO BE RE-USED. PART 5 - CUTTING AND PATCHING PERMITTED AT OUTLETS AND JUNCTION BOXES. 22.5 REFER TO THE LUMINAIRE SCHEDULE FOR EACH TYPE REQUIRED TO MEET THE NEEDS OF THE 5.1 THE BUILDING AND PARKADE CONTAIN POST TENSION CABLES WITHIN THE CONCRETE SLABS AND 13.9 PROVIDE A BONDING WIRE IN ALL RACEWAYS. STRUCTURE. THE DETAILS OF ALL PROPOSED OPENINGS, PENETRATIONS AND INSERTS THROUGH PROJECT. ALTERNATES MAY BE CONSIDERED DURING THE TENDER PERIOD, REFER TO PART 7 - THE SLABS, BEAMS OR WALLS MUST BE SUBMITTED FOR REVIEW AND APPROVAL TO THE 13.10 ALL WIRING TO BE CONCEALED IN WALLS, CEILINGS OR FLOORS, WHERE POSSIBLE. EXPOSED SUBSTITUTIONS. CONDUIT OR WIRING SHALL BE RUN PARALLEL TO OR AT RIGHT ANGLES TO THE BUILDING LINES. STRUCTURAL ENGINEER AND LANDLORD AND HIS BASE BUILDING STRUCTURAL ENGINEER. PROVIDE PART 23 - LIGHTING CONTROLS ALL COSTS FOR X-RAY OR OTHER INVESTIGATIONS TO THE SATISFACTION OF THE LANDLORD PRIOR 13.11 PULL BOXES SHALL BE INSTALLED TO BE AS HIDDEN AS POSSIBLE WITHOUT IMPEDING ACCESS. 23.1 LIGHTING CONTACTORS SHALL BE EQUAL TO EATON TYPE A202, MAGNETICALLY LATCHED. TO ANY WORK WITH THE STRUCTURAL CONCRETE SYSTEMS. PART 14 - WIRING DEVICES 23.2 LIGHTING CONTROLS SHALL BE TESTED, BY A PARTY INDEPENDENT TO THE DESIGN OR 5.2 STRUCTURAL MEMBERS SHALL NOT BE CUT WITHOUT THE CONSENT OF THE ENGINEER AND/OR 14.1 LIGHT SWITCHES SHALL BE COMMERCIAL GRADE, DECORA STYLE, 15 OR 20A AS REQUIRED, WHITE CONSTRUCTION OF THE PROJECT, CERTIFICATION THAT ALL LIGHTING CONTROL DEVICES HAVE STRUCTURAL ENGINEER ON SITE. FOR ALL NECESSARY CUTTING, CORING, DRILLING, ETC., THE FINISH, UNLESS OTHERWISE NOTED. BEEN CALIBRATED, ADJUSTED, PROGRAMMED AND ARE IN PROPER WORKING ORDER IN ELECTRICAL CONTRACTOR SHALL PROVIDE HIS OWN FORCES AND NECESSARY EQUIPMENT 14.2 RECEPTACLES SHALL BE COMMERCIAL GRADE, DECORA STYLE, 15 OR 20A AS REQUIRED, WHITE ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND MANUFACTURER'S RECOMMENDATIONS, REQUIRED TO COMPLETE THE WORK. FINISH, UNLESS OTHERWISE NOTED. WHICH INCLUDE THE FOLLOWING: 5.3 PRIOR TO RUNNING ANY DUCTS IN THE SLAB OR OTHER CONCRETE MEMBERS, CONTACT THE 14.3 COVER PLATES SHALL BE THERMOPLASTIC IN FINISHED AREAS WITH COLOUR TO MATCH DEVICES. .1 CONFIRM PLACEMENT, SENSITIVITY AND TIME-OUT FOR OCCUPANCY SENSORS YIELD STRUCTURAL ENGINEER AND OBTAIN CONSENT, IN WRITING, FOR DOING SO. PROVIDE STAMPED METAL COVER PLATES IN UNFINISHED AREAS AND WEATHERPROOF 'IN-USE' ACCEPTABLE PERFORMANCE AND LIGHTS TURN OFF ONLY AFTER SPACE IS VACATED AND DO PART 6 - SUBSTITUTIONS COVERS FOR EXTERIOR RECEPTACLES. NOT TURN ON UNLESS SPACE IS OCCUPIED. 6.1 WHERE EQUIPMENT IS SPECIFIED WITH A MANUFACTURER'S NAME, SUBSTITUTIONS MAY BE 14.4 LINE VOLTAGE DIMMERS SHALL BE EQUAL TO LEVITON DECORA ROCKER-SLIDE UNIVERSAL SERIES .2 CONFIRM TIME SWITCHES AND PROGRAMMABLE SCHEDULES ARE PROGRAMMED TO TURN PERMITTED UPON WRITTEN APPROVAL OF THE ENGINEER NO LATER THAN THREE DAYS PRIOR TO (1000W), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLE SWITCHES. THE LIGHTS OFF. TENDER CLOSING. SUBMIT A LIST OF PROPOSED EQUIVALENT PRODUCTS TO THE ENGINEER IN PDF 14.5 0-10VDC DIMMERS SHALL BE EQUAL TO LEVITON DECORA ROCKER-SLIDE ADVANCE MARK 7 SERIES .3 PHOTO CONTROLS REDUCE LIGHTING LEVELS BASED ON AMOUNT OF USABLE DAYLIGHT IN FORMAT, VIA EMAIL. MATERIALS NOTED AS "EQUAL TO" MAY BE SUBSTITUTED FOR EQUAL OR (1200VA), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLE SWITCHES. THE SPACE. SUPERIOR QUALITY WITHOUT WRITTEN APPROVAL. PART 24 - GROUNDING 14.6 ELECTRONIC LOW VOLTAGE DIMMERS SHALL BE EQUAL TO LEVITON DECORA ROCKER-SLIDE 6.2 ENSURE SPACE REQUIREMENTS ARE MET IF USING SERVICE AND DISTRIBUTION EQUIPMENT FROM UNIVERSAL SERIES (600VA), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLE SWITCHES. 24.1 SUPPLY AND INSTALL COMPLETE GROUNDING AND BONDING SYSTEM AS INDICATED AND AS ALTERNATE MANUFACTURERS. FAILURE TO DO SO THAT REQUIRES REDESIGN OF ELECTRICAL REQUIRED BY THE CURRENT EDITION OF THE CANADIAN ELECTRICAL CODE AND ELECTRICAL 14.7 LINE VOLTAGE SWITCHES WITH INTEGRAL PIR OCCUPANCY SENSORS SHALL BE EQUAL TO LEVITON ROOMS WILL NOT BE ACCEPTED. ENGINEER'S COST CAUSED BY FAILURE TO COMPLY WILL BE INSPECTION DEPARTMENT. ALL COMPONENTS SHALL BE SECURELY AND ADEQUATELY GROUNDED DECORA ODS15-ID (1800VA), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLE SWITCHES. CHARGED TO THE ELECTRICAL CONTRACTOR. AND WHERE REQUIRED TO ACCOMPLISH THIS, GROUNDING JUMPERS, GROUNDING STUDS AND PART 7 - SHOP DRAWINGS 14.8 LINE VOLTAGE SWITCHES WITH INTEGRAL PIR/ULTRASONIC OCCUPANCY SENSORS SHALL BE BUSHINGS SHALL BE USED. ENSURE THAT ALL RACEWAYS, TERMINAL PANELS, ETC. FOR EQUAL TO LEVITON DECORA OSSMT-MD (800W), WITH IVORY FINISH. DO NOT GANG WITH STANDARD 7.1 SUBMIT ELECTRONIC SETS OF MANUFACTURER'S DETAILED SHOP DRAWINGS, SPECIFICATIONS, TELEPHONE, LOW VOLTAGE, FIRE ALARM, SOUND, ETC. ARE SECURELY AND ADEQUATELY TOGGLE SWITCHES. DATA SHEETS, ETC. FOR EQUIPMENT INCLUDING, BUT NOT LIMITED TO: SWITCHGEAR, GROUNDED AND PROVIDE GROUNDING CONDUCTOR TO WATER MAIN WHERE CALLED FOR OR PANELBOARDS, SERVICE EQUIPMENT, SWITCHES, LIGHTING, CONTROLS OR AS MAY BE 14.9 LINE VOLTAGE SWITCHES WITH INTEGRAL PIR OCCUPANCY SENSORS AND 0-10V DIMMING SHALL BE WHERE REQUIRED. 01 CONSIDERED NECESSARY TO THE ENGINEER. EQUAL TO LEVITON OSD10-10 (800W), WITH IVORY FINISH. DO NOT GANG WITH STANDARD TOGGLE PART 25 - FIRE ALARM SYSTEM - 11 SWITCHES. (ASHRAE 90.1 COMPLIANT) - 7.2 CIMA+ HAS ALLOWED FOR TWO SHOP DRAWING REVIEWS FOR EACH SYSTEM. ALL COSTS .1 THE EXISTING FIRE ALARM SYSTEM SHALL BE MAINTAINED DURING CONSTRUCTION. NO

ASSOCIATED WITH CIMA+ PROVIDING ADDITIONAL SHOP DRAWING REVIEWS SHALL BE HOURLY AT 14.10 LINE VOLTAGE CEILING MOUNT PIR OCCUPANCY SENSORS SHALL BE EQUAL TO LEVITON PROVOLT CHANGES ARE ANTICIPATED FOR THE FIRE ALARM SYSTEM. Scale NTS Date 2018 THE CONTRACTOR'S COST. SERIES ODC15-ID (800W, 360°, 1500SQFT COVERAGE), WITH WHITE FINISH. PART 26 - SECURITY - ACCESS CONTROL 7.3 NO PRODUCT IS TO BE ORDERED, INSTALLED OR RELATED WORK IS TO BE DONE UNTIL THE SHOP 14.11 LINE VOLTAGE CEILING MOUNT PIR/ULTRASONIC OCCUPANCY SENSORS SHALL BE EQUAL TO 26.1 FOUR DOOR CONTROLLER: KANTECH KT-400 DOOR CONTROLLER OR APPROVED EQUAL. DRAWING HAS BEEN REVIEWED BY THE CONSULTANT. ANY ELECTRICAL COMPONENTS INSTALLED LEVITON PROVOLT SERIES ODC20-MDW (800W, 360°, 2000SQFT COVERAGE), WITH WHITE FINISH. 5R8 V2L 26.2 PROXIMITY CARDS & READERS: KANTECH IOPROX READERS OR APPROVED EQUAL, SINGLE GANG OR RELATED WORK DONE WITHOUT REVIEWED SHOP DRAWINGS, SHALL BE REMOVED AND 14.12 LINE VOLTAGE WALL/CORNER MOUNT PIR OCCUPANCY SENSORS (WIDE VIEW) SHALL BE EQUAL TO OR MULLION MOUNT, KEYPAD AS INDICATED ON DRAWINGS. KANTECH IOPROX CARDS, TAGS, OR REPLACED WITH REVIEWED COMPONENTS AND WORK AT THE CONSULTANT'S DISCRETION AND AT LEVITON ODWWV-ID (15A, 110°, 2500SQFT COVERAGE), WITH WHITE FINISH. KEY FOBS AS PER OWNER REQUIREMENTS. THE CONTRACTOR'S COST. 14.13 LINE VOLTAGE WALL/CORNER MOUNT PIR OCCUPANCY SENSORS (LONG RANGE AISLE) SHALL BE PRINCE GEORGE, B.C. PRINCE GEORGE, 26.3 REQUEST TO EXIT DETECTOR: KANTECH T.REX OR APPROVED EQUAL. VICTORIA STREET 177 7.4 ANY TIME SPENT BY THE CONSULTANT DUE TO CONTRACTOR EQUIPMENT SELECTIONS THAT EQUAL TO LEVITON ODWLR-ID (15A, 110°, 1200SQFT COVERAGE), WITH WHITE FINISH. -

REQUIRE REDESIGN OR COORDINATION REVIEW WITH OTHER SYSTEMS OR DISCIPLINES SHALL BE 26.4 REQUEST TO EXIT PUSH BUTTON: KANTECH PB-EXIT OR APPROVED EQUAL. 200 14.14 LINE VOLTAGE WALL/CORNER MOUNT PIR/ULTRASONIC OCCUPANCY SENSORS SHALL BE EQUAL TO PAID BY THE CONTRACTOR DIRECTLY TO THE CONSULTANT AT AN HOURLY COST. THE LEVITON ODW12-MDW (15A, 100FT X 14FT @ 10FT MOUNTING HEIGHT), WITH WHITE FINISH. 26.5 ELECTRIC STRIKE: SECURITRON UNL FOR CYLINDRICAL/TUBULAR LOCKSET OR MUNL FOR MORTISE CONTRACTOR SHALL REPLACE ANY ALTERNATE PRODUCTS WITH THE APPROVED PRODUCTS TYPE LOCK, OR APPROVED EQUALS. FAIL SAFE OR FAIL SECURE AS INDICATED ON DRAWINGS. SHOULD THEY NOT MEET ALL THE REQUIREMENTS OF THE LAYOUTS, DIMENSIONS, PERFORMANCE PART 15 - MOUNTING HEIGHTS 26.6 MAGLOCK: SECURITRON MAGNALOCK M62 SERIES AND DM62 SERIES FOR DOUBLE DOORS OR SPECIFICATIONS, DELIVERY TIME AND COORDINATION WITH OTHER DISCIPLINES TO THE 15.1 MOUNTING HEIGHTS SHALL BE FROM THE FINISHED FLOOR TO THE CENTRE OF EQUIPMENT, UNLESS APPROVED EQUALS. SATISFACTION OF THE CONSULTANT. THE CONTRACTOR SHALL ALLOW FOR ALL COSTS IN THEIR OTHERWISE NOTED. IF MOUNTING HEIGHT IS NOT SPECIFIED, VERIFY WITH ENGINEER PRIOR TO BASE TENDER PRICE FOR THESE REQUIREMENTS. INSTALLATION. 26.7 SOFTWARE: ENTRAPASS SPECIAL EDITION OR APPROVED EQUAL. 26.8 POWER TO COME FROM INDEPENDENT 120 VOLT, 15 AMP CIRCUIT. CIRCUIT DISCONNECT DEVICE FIRST NATIONS NATIONS HEALTH FIRST AUTHORITY Project Drawing FNHA PRINCE GEORGEOFFICE PRINCE FNHA RENO. .1 SWITCHES: 1200MM (48 IN.) SPECIFICATIONS ACCESSIBLE TO AUTHORIZED PERSONNEL ONLY. .2 RECEPTACLES: 305MM (12 IN.) .3 TELEPHONE/DATA/TELEVISION OUTLETS: 450MM (18 IN.) .4 FIRE ALARM PULL STATIONS: 1200MM (48 IN.) Sheet Number Sheet Project Number Project K000293A E-400

PRINTED: 11/15/2018 2:50:14 PM