Infrared Spectroscopy
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Chapter 9 Titrimetric Methods 413
Chapter 9 Titrimetric Methods Chapter Overview Section 9A Overview of Titrimetry Section 9B Acid–Base Titrations Section 9C Complexation Titrations Section 9D Redox Titrations Section 9E Precipitation Titrations Section 9F Key Terms Section 9G Chapter Summary Section 9H Problems Section 9I Solutions to Practice Exercises Titrimetry, in which volume serves as the analytical signal, made its first appearance as an analytical method in the early eighteenth century. Titrimetric methods were not well received by the analytical chemists of that era because they could not duplicate the accuracy and precision of a gravimetric analysis. Not surprisingly, few standard texts from the 1700s and 1800s include titrimetric methods of analysis. Precipitation gravimetry developed as an analytical method without a general theory of precipitation. An empirical relationship between a precipitate’s mass and the mass of analyte— what analytical chemists call a gravimetric factor—was determined experimentally by taking a known mass of analyte through the procedure. Today, we recognize this as an early example of an external standardization. Gravimetric factors were not calculated using the stoichiometry of a precipitation reaction because chemical formulas and atomic weights were not yet available! Unlike gravimetry, the development and acceptance of titrimetry required a deeper understanding of stoichiometry, of thermodynamics, and of chemical equilibria. By the 1900s, the accuracy and precision of titrimetric methods were comparable to that of gravimetric methods, establishing titrimetry as an accepted analytical technique. 411 412 Analytical Chemistry 2.0 9A Overview of Titrimetry We are deliberately avoiding the term In titrimetry we add a reagent, called the titrant, to a solution contain- analyte at this point in our introduction ing another reagent, called the titrand, and allow them to react. -
ADVANCED SPECTROMETER Introduction
ADVANCED SPECTROMETER Introduction In principle, a spectrometer is the simplest of scientific very sensitive detection and precise measurement, a real instruments. Bend a beam of light with a prism or diffraction spectrometer is a bit more complicated. As shown in Figure grating. If the beam is composed of more than one color of 1, a spectrometer consists of three basic components; a light, a spectrum is formed, since the various colors are collimator, a diffracting element, and a telescope. refracted or diffracted to different angles. Carefully measure The light to be analyzed enters the collimator through a the angle to which each color of light is bent. The result is a narrow slit positioned at the focal point of the collimator spectral "fingerprint," which carries a wealth of information lens. The light leaving the collimator is therefore a thin, about the substance from which the light emanates. parallel beam, which ensures that all the light from the slit In most cases, substances must be hot if they are to emit strikes the diffracting element at the same angle of inci- light. But a spectrometer can also be used to investigate cold dence. This is necessary if a sharp image is to be formed. substances. Pass white light, which contains all the colors of The diffracting element bends the beam of light. If the beam the visible spectrum, through a cool gas. The result is an is composed of many different colors, each color is dif- absorption spectrum. All the colors of the visible spectrum fracted to a different angle. are seen, except for certain colors that are absorbed by the gas. -
Analytical Chemistry Laboratory Manual 2
ANALYTICAL CHEMISTRY LABORATORY MANUAL 2 Ankara University Faculty of Pharmacy Department of Analytical Chemistry Analytical Chemistry Practices Contents INTRODUCTION TO QUANTITATIVE ANALYSIS ......................................................................... 2 VOLUMETRIC ANALYSIS .............................................................................................................. 2 Volumetric Analysis Calculations ................................................................................................... 3 Dilution Factor ................................................................................................................................ 4 Standard Solutions ........................................................................................................................... 5 Primary standard .............................................................................................................................. 5 Characteristics of Quantitative Reaction ......................................................................................... 5 Preparation of 1 L 0.1 M HCl Solution ........................................................................................... 6 Preparation of 1 L 0.1 M NaOH Solution ....................................................................................... 6 NEUTRALIZATION TITRATIONS ...................................................................................................... 7 STANDARDIZATION OF 0.1 N NaOH SOLUTION ...................................................................... -
Using Visible and Near-Infrared Reflectance Spectroscopy and Differential Scanning Calorimetry to Study Starch, Protein, and Temperature Effects on Bread Staling
Using Visible and Near-Infrared Reflectance Spectroscopy and Differential Scanning Calorimetry to Study Starch, Protein, and Temperature Effects on Bread Staling Feng Xie,1 Floyd E. Dowell,2,3 and Xiuzhi S. Sun1 ABSTRACT Cereal Chem. 81(2):249–254 Starch, protein, and temperature effects on bread staling were inves- retrograded amylose-lipid complex was limited. Two important wave- tigated using visible and near-infrared spectroscopy (NIRS) and differ- lengths, 550 nm and 1,465 nm, were key for NIRS to successfully classify ential scanning calorimetry (DSC). Bread staling was mainly due to the starch-starch (SS) and starch-protein (SP) bread based on different amylopectin retrogradation. NIRS measured amylopectin retrogradation colors and protein contents in SS and SP. Low temperature dramatically accurately in different batches. Three important wavelengths, 970 nm, accelerated the amylopectin retrogradation process. Protein retarded bread 1,155 nm, and 1,395 nm, were associated with amylopectin retrogra- staling, but not as much as temperature. The starch and protein interaction dation. NIRS followed moisture and starch structure changes when was less important than the starch retrogradation. Protein hindered the amylopectin retrograded. The amylose-lipid complex changed little from bread staling process mainly by diluting starch and retarding starch retro- one day after baking. The capability of NIRS to measure changes in the gradation. Bread staling is a complex process that occurs during bread and starch (Osborne and Douglas 1981; Davies and Miller 1988; storage. It is a progressive deterioration of qualities such as taste, Millar et al 1996). Therefore, NIRS has the potential to provide fun- firmness, etc. -
Vacuum Ultra Violet Monochromator I Grating & OEM
Feature Article JY Division nformation Vacuum Ultra Violet Monochromator I Grating & OEM Erick Jourdain Abstract Taking the advantage of Jobin Yvon(JY) leading position in the design and realisation of diffraction grating JY has developed over the last past 30 years some of the most innovative Vacuum Ultra Violet (VUV) monochromators for synchrotron centre. These monochromators, which combine the ultimate advanced diffraction grating technologies and some ultra precise under vacuum mechanics, have been installed in several synchrotron centres and have demonstrated superior performances. Today the development of new compact VUV sources and applications require compact VUV monochromators. Based on diffraction grating capabilities and our large experience acquired in the difficult and demanding market of under vacuum synchrotron monochromators JY is currently developing new compact monochromators for application such as Extreme UV lithography or X-ray Photoemission Spectroscopy. Introduction In the middle of the seventies thank to the development of the aberration corrected holographic toroidal gratings at Jobin Yvon (JY) we introduced on the market a new VUV monochromator concept that drastically enhanced the spectroscopic performances in this field [1]. During the eighties the Toroidal Grating Monochromator (TGM) and its associated toroidal gratings had a large and world wide success. At that time most of the synchrotron VUV beamline got equipped with this monochromator type and even today some recent beamline are still been developed Fig. -
FT-IR Spectroscopy
ORIEL ORIEL PRODUCT TRAINING FT-IR Spectroscopy SECTION FOUR FEATURES • Glossary of Terms • Introduction to FT-IR Spectroscopy Stratford, CT • Toll Free 800.714.5393 Fax 203.378.2457 • www.newport.com/oriel • [email protected] GLOSSARY OF TERMS Before we start the technical discussion on FT-IR Spectrometers, we devote a couple of pages to a Glossary, to facilitate the discussion that follows. 100% Line: Calculated by ratioing two background spectra Collimation: The ideal input beam is a cylinder of light. No taken under identical conditions. Ideally, the result is a flat beam of finite dimensions can be perfectly collimated; at best line at 100% transmittance. there is a diffraction limit. In practice the input beam is a Absorbance: Units used to measure the amount of IR cone that is determined by the source size or aperture used. radiation absorbed by a sample. Absorbance is commonly The degree of collimation can affect the S/N and the used as the Y axis units in IR spectra. Absorbance is defined resolution. by Beer’s Law, and is linearly proportional to concentration. Constructive Interference: A phenomenon that occurs when Aliasing: If frequencies above the Nyquist Frequency are not two waves occupy the same space and are in phase with filtered out, energy in these will appear as spectral artefacts each other. Since the amplitudes of waves are additive, the below the Nyquist Frequency. Optical and electronic anti two waves will add together to give a resultant wave which is aliasing can be used to prevent this. Sometimes the higher more intense than either of the individual waves. -
Spectrum 100 Series User's Guide
MOLECULAR SPECTROSCOPY SPECTRUM 100 SERIES User’s Guide 2 . Spectrum 100 Series User’s Guide Release History Part Number Release Publication Date L1050021 A October 2005 Any comments about the documentation for this product should be addressed to: User Assistance PerkinElmer Ltd Chalfont Road Seer Green Beaconsfield Bucks HP9 2FX United Kingdom Or emailed to: [email protected] Notices The information contained in this document is subject to change without notice. Except as specifically set forth in its terms and conditions of sale, PerkinElmer makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. PerkinElmer shall not be liable for errors contained herein for incidental consequential damages in connection with furnishing, performance or use of this material. Copyright Information This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be reproduced in any form whatsoever or translated into any language without the prior, written permission of PerkinElmer, Inc. Copyright © 2005 PerkinElmer, Inc. Trademarks Registered names, trademarks, etc. used in this document, even when not specifically marked as such, are protected by law. PerkinElmer is a registered trademark of PerkinElmer, Inc. Spectrum, Spectrum 100, and Spectrum 100N are trademarks of PerkinElmer, Inc. Spectrum 100 Series User’s Guide . 3 Contents Contents............................................................................................... -
Analytical Chemistry in the 21St Century: Challenges, Solutions, and Future Perspectives of Complex Matrices Quantitative Analyses in Biological/Clinical Field
Review Analytical Chemistry in the 21st Century: Challenges, Solutions, and Future Perspectives of Complex Matrices Quantitative Analyses in Biological/Clinical Field 1, 2, 2, 3 Giuseppe Maria Merone y, Angela Tartaglia y, Marcello Locatelli * , Cristian D’Ovidio , Enrica Rosato 3, Ugo de Grazia 4 , Francesco Santavenere 5, Sandra Rossi 5 and Fabio Savini 5 1 Department of Neuroscience, Imaging and Clinical Sciences, University of Chieti–Pescara “G. d’Annunzio”, Via dei Vestini 31, 66100 Chieti, Italy; [email protected] 2 Department of Pharmacy, University of Chieti-Pescara “G. d’Annunzio”, Via Dei Vestini 31, 66100 Chieti (CH), Italy; [email protected] 3 Section of Legal Medicine, Department of Medicine and Aging Sciences, University of Chieti–Pescara “G. d’Annunzio”, 66100 Chieti, Italy; [email protected] (C.D.); [email protected] (E.R.) 4 Laboratory of Neurological Biochemistry and Neuropharmacology, Fondazione IRCCS Istituto Neurologico Carlo Besta, Via Celoria 11, 20133 Milano, Italy; [email protected] 5 Pharmatoxicology Laboratory—Hospital “Santo Spirito”, Via Fonte Romana 8, 65124 Pescara, Italy; [email protected] (F.S.); [email protected] (S.R.); [email protected] (F.S.) * Correspondence: [email protected]; Tel.: +39-0871-3554590; Fax: +39-0871-3554911 These authors contributed equally to the work. y Received: 16 September 2020; Accepted: 16 October 2020; Published: 30 October 2020 Abstract: Nowadays, the challenges in analytical chemistry, and mostly in quantitative analysis, include the development and validation of new materials, strategies and procedures to meet the growing need for rapid, sensitive, selective and green methods. -
Experiment 5 – IR Exercise Reading Assignment Mohrig Chapter 21
CHEM 8L, Binder UCSC Experiment 5 – IR Exercise Reading Assignment Mohrig Chapter 21 In this experiment, students will study the infrared (IR) spectra of compounds with different functional groups. The purpose of the experiment is to become familiar with the IR spectrometer, the preparation and handling of IR samples, and the interpretation of IR spectra. CHEM 108M students use the IR nearly every lab. You will obtain the IR spectra of aspirin, carvone, and methyl salicylate (wintergreen oil). Carvone and methyl salicylate are liquids and their IRs are obtained directly from a very small drop of pure (aka “neat”) material. Aspirin is a solid and must be diluted before the IR is obtained. O O OH O O O OCH3 OH Methyl Salicylate Acetylsalicylic Acid Carvone (Wintergreen Oil) (Aspirin) Figure 1. Structures of compounds to be analyzed by IR. IR spectroscopy is similar to spectrophotometry, a technique that is used in the general chemistry labs to determine concentration of samples based on absorbance of visible light. In spectrophotometry, a colored sample absorbs light in the visible range of the electromagnetic spectrum. IR spectroscopy explores a different range of frequencies in order to determine the types of bonds and functional groups present but does not require a visible color in the compound. Absorption of IR radiation results in the stretching and bending of bonds in ways characteristic to the functional group. Before beginning to prepare the notebook for this lab, read the sections on IR in the Mohrig text and attend the IR lecture! You may bring this handout to lab to compare with literature IR, but you still need to prepare your lab notebook or you will not be permitted to enter the lab (zero points on the report). -
Experiment 2 Radiation in the Visible Spectrum Emission Spectra Can Be
Experiment 2 Radiation in the Visible Spectrum Emission spectra can be a unique fingerprint of an atom or molecule. The photon energies and wavelengths are directly related to the allowed quantum energy states of the system. In the following experiments we will examine the radiation given off by sources radiating in the visible region. We will be using a spectrometer produced by Ocean Optics. Light enters the spectrometer via a fiber optic cable. Inside the spectrometer a diffraction grating diffracts the different frequencies onto a CCD. The CCD basically ”counts” the photons according to wavelength. The data is transferred via a usb port to a PC. The Ocean Optics software displays the spectrum as counts versus wavelength. We will examine the spectra given off by the following sources: incandescent light filament, hydrogen, helium, various light emitting diodes and a laser pointer. You will also be given an unknown gas discharge tube and will need to identify the gas via its spectral emissions Pre Lab 1) Obtain a spectrum for hydrogen, mercury, sodium and neon gas emissions. The spectrum must contain an accurate listing of major emission lines (in nm), not simply a color photo of the emission. 2) Make yourself familiar with the manual for the spectrometer and the software. These are available via the following links: http://www.oceanoptics.com/technical/hr4000.pdf http://www.oceanoptics.com/technical/SpectraSuite.pdf These documents are also available on Black Board. 3) How does the Ocean Optics spectrometer work? In your answer list its three main components and describe what each component does. -
"Thermal Analysis and Calorimetry," In
Article No : b06_001 Thermal Analysis and Calorimetry STEPHEN B. WARRINGTON, Formerly Anasys, IPTME, Loughborough University, Loughborough, United Kingdom Gu€NTHER W. H. Ho€HNE, Formerly Polymer Technology (SKT), Eindhoven University of Technology, Eindhoven, The Netherlands 1. Thermal Analysis.................. 415 2.2. Methods of Calorimetry............. 424 1.1. General Introduction ............... 415 2.2.1. Compensation of the Thermal Effects.... 425 1.1.1. Definitions . ...................... 415 2.2.2. Measurement of a Temperature Difference 425 1.1.2. Sources of Information . ............. 416 2.2.3. Temperature Modulation ............. 426 1.2. Thermogravimetry................. 416 2.3. Calorimeters ..................... 427 1.2.1. Introduction ...................... 416 2.3.1. Static Calorimeters ................. 427 1.2.2. Instrumentation . .................. 416 2.3.1.1. Isothermal Calorimeters . ............. 427 1.2.3. Factors Affecting a TG Curve ......... 417 2.3.1.2. Isoperibolic Calorimeters ............. 428 1.2.4. Applications ...................... 417 2.3.1.3. Adiabatic Calorimeters . ............. 430 1.3. Differential Thermal Analysis and 2.3.2. Scanning Calorimeters . ............. 430 Differential Scanning Calorimetry..... 418 2.3.2.1. Differential-Temperature Scanning 1.3.1. Introduction ...................... 418 Calorimeters ...................... 431 2.3.2.2. Power-Compensated Scanning Calorimeters 432 1.3.2. Instrumentation . .................. 419 2.3.2.3. Temperature-Modulated 1.3.3. Applications ...................... 419 Scanning Calorimeters . ............. 432 1.3.4. Modulated-Temperature DSC (MT-DSC) . 421 2.3.3. Chip-Calorimeters .................. 433 1.4. Simultaneous Techniques............ 421 2.4. Applications of Calorimetry.......... 433 1.4.1. Introduction ...................... 421 2.4.1. Determination of Thermodynamic Functions 433 1.4.2. Applications ...................... 421 2.4.2. Determination of Heats of Mixing . .... 434 1.5. Evolved Gas Analysis.............. -
Technical Application Note
Compact Rugged Spectrometers - A Universe of Spectroscopy Systems Technical Application Note Vibrational Spectroscopy: Infrared vs. Raman StellarNet, Inc. Tampa, Fl USA Tony Rizzuto, PhD April 12, 2017 Vibrational spectroscopies are integral in analyzing some of the most fundamentally important processes in physical chemistry: molecular vibrations. While there are many different experimental techniques used to analyze those vibrations, most are variations of the “Big Two,” FTIR and Raman scattering spectroscopies. This article aims to analyze the benefits and drawbacks of each of the “Big Two,” with the hope that it helps one choose the correct technique for one’s research interests. 1. What are the “Big Two?” Fourier Transform Infrared Spectroscopy Raman spectroscopy relies on inelastic (FTIR) is a simple absorption measurement scattering phenomenon that probes the where the detector measures the molecular vibration. Where FTIR will use a absorbance of infrared radiation by the broadband IR source, Raman spectroscopy sample. Each sample will absorb different typically uses a narrow-band, amounts of each frequency resulting in a monochromatic light source in order to “chemical fingerprint” that is the FTIR excite the vibrations of the molecule in your spectrum. sample. 2. Selection Rules: What molecular vibrations are being probed? Imagining a molecular bond vibration with the traditional ball and spring model (Figure 1a) and its resultant harmonic oscillator depiction (Figure 1b) allows us to calculate the selection rules for vibrational transitions to be = 1. However, that does not tell the whole story. In order to truly differentiate FTIR from Raman Spectroscopy, we must think about it on a molecular level. Compact Rugged Spectrometers - A Universe of Spectroscopy Systems Technical Application Note A B Figure 1: A.