• A1 is submission for P1a on or before the part A deadline. Lecture 13 – RAID • A2 is version of P1a submitted *any time* before the part B deadline. Thanks to Greg Ganger and Remzi Arapaci-Dusseau for • B_self is part B running against your own implementation of LSP slides • 0.9*B_with_staff_code is part B running against the reference LSP

1

Replacement Rates Outline

HPC1! COM1! COM2! Component! %! Component! %! Component! %! • Using multiple disks Hard drive! 30.6! Power supply! 34.8! Hard drive! 49.1! • Why have multiple disks? Memory! 28.5! Memory! 20.1! Motherboard! 23.4! Misc/Unk! 14.4! Hard drive! 18.1! Power supply! 10.1! • problem and approaches CPU! 12.4! Case! 11.4! RAID card! 4.1! motherboard! 4.9! Fan! 8! Memory! 3.4! Controller! 2.9! CPU! 2! SCSI cable! 2.2! QSW! 1.7! SCSI Board! 0.6! Fan! 2.2! • RAID levels and performance Power supply! 1.6! NIC Card! 1.2! CPU! 2.2! MLB! 1! LV Pwr Board! 0.6! CD-ROM! 0.6! SCSI BP! 0.3! CPU heatsink! 0.6! Raid Controller! 0.6! • Estimating availability

3 4

Motivation: Why use multiple disks? JustJust a bunch a bunch of of disks disks (JBOD) (JBOD)

• Capacity • More disks allows us to store more data A0 B0 C0 D0 • Performance • Access multiple disks in parallel A1 B1 C1 D1 • Each disk can be working on independent read or write • Overlap seek and rotational positioning time for all • Reliability A2 B2 C2 D2 • Recover from disk (or single sector) failures • Will need to store multiple copies of data to recover A3 B3 C3 D3

• So, what is the simplest arrangement? • Yes, it’s a goofy name • industry Yes, it’sreally a goofydoes sellname “JBOD enclosures”  industry really does sell “JBOD enclosures”

October 2010, Greg Ganger © 6 4

1 3/4/14

Disk Subsystem Load Balancing Disk Striping

• I/O requests are almost never evenly distributed • InterleaveDisk Striping data across multiple disks • Some data is requested more than other data • Large file streaming can enjoy parallel transfers • Depends on the apps, usage, time, ...  Interleave data across multiple disks • What is the right data-to-disk assignment policy? • High Large throughput file streaming requests can enjoycan enjoy parallel thorough transfers load • Common approach: Fixed data placement balancing High throughput requests can enjoy thorough load balancing • Your data is on disk X, period! • If blocks If blocks of of hot hot files files equallyequally likely likely on all on disks all disks(really?) (really?) • For good reasons too: you bought it or you’re paying more... • Fancy: Dynamic data placement File Foo: " • If some of your files are accessed a lot, the admin(or even stripe unit system) may separate the “hot” files across multiple disks or block • In this scenario, entire files systems (or even files) are manually moved by the system admin to specific disks • Alternative: Disk striping • Stripe all of the data across all of the disks Stripe"

7 8

October 2010, Greg Ganger © 8

Disk striping details Now, What If A Disk Fails?

• How disk striping works • In a JBOD (independent disk) system • Break up total space into fixed-size stripe units • one or more file systems lost • Distribute the stripe units among disks in round-robin • In a striped system • Compute location of block #B as follows • a part of each file system lost • disk# = B%N (%=modulo,N = #ofdisks) • LBN# = B / N (computes the LBN on given disk) • Backups can help, but • backing up takes time and effort • backup doesn’t help recover data lost during that day • Any data loss is a big deal to a bank or stock exchange

9 10

Tolerating and masking disk failures Redundancy via replicas Redundancy via replicas • If a disk fails, it’s data is gone • Two (or more) copies  Two (or more) copies • may be recoverable, but may not be • mirroring, shadowing, duplexing, etc.  mirroring, shadowing, duplexing, etc. • To keep operating in face of failure • Write Write both, both, read read either either • must have some kind of • Common forms of data redundancy • 0 0 2 2 • erasure-correcting codes • error-correcting codes

1 1 3 3

11 12

October 2010, Greg Ganger © 16

2 3/4/14

Implementing MirroringMirroring & Striping & Striping Implementing Disk Mirroring  Mirroring can be done in either software or hardware  Mirror to 2 virtual drives, where each virtual drive is • Mirror to 2 virtual drives, where each virtual drive is • SoftwareMirroring can solutions be done are in availableeither software in most or hardware OS’s really a set of striped drives • Software solutions are available in most OS’s really a set of striped drives  Windows2000, Linux, Solaris • Windows2000, Linux, Solaris  Provides• Provides reliability reliability of ofmirroring mirroring • Hardware solutions solutions  Provides• Provides striping striping for for performance performance (with (with write write update update costs) costs) • Could bebe done done in in Host Host Bus Bus Adaptor(s) Adaptor(s) • Could bebe done done in in Disk Array Controller Controller

October 2010, Greg Ganger © 18 October 2010, Greg Ganger © 17 13 14

Hardware vs. Software RAID Lower Cost Data Redundancy

• Hardware RAID • Single failure protecting codes • Storage box you attach to computer • general single-error-correcting code is overkill • Same interface as single disk, but internally much more • General code finds error and fixes it • Multiple disks • Disk failures are self-identifying (a.k.a. erasures) • More complex controller • Don’t have to find the error • NVRAM (holding parity blocks) • Fact: N-error-detecting code is also N-erasure- • Software RAID correcting • OS (device driver layer) treats multiple disks like a single disk • Error-detecting codes can’t find an error,just know its there • Software does all extra work • But if you independently know where error is, allows repair • Interface for both • Parity is single-disk-failure-correcting code • Linear array of bytes, just like a single disk (but larger) • recall that parity is computed via XOR • it’s like the low bit of the sum

16

Updating and using the parity Simplest approach: Parity Disk Updating and using the parity Simplest approach: Parity Disk • One extra disk Fault-Free Read Fault-Free Write • All writes update  One extra disk 2 4 parity disk A A A A Ap 1 3  All writes update • Potential D D D P D D D P parity disk bottleneck B B B B Bp  potential bottleneck Degraded Read Degraded Write C C C C Cp

D D D D Dp D D D P D D D P

17 18

October 2010, Greg Ganger © October 2010, Greg Ganger © 20 23

3 3/4/14

The parity disk bottleneck Solution: Striping the Parity Solution: Striping the Parity • Reads go only to the data disks • Removes parity disk bottleneck • But, hopefully load balanced across the disks  Removes parity A A A A Ap • All writes go to the parity disk disk bottleneck • And, worse, usually result in Read-Modify-Write B B B Bp B sequence • So, parity disk can easily be a bottleneck C C Cp C C

D Dp D D D

19 20

October 2010, Greg Ganger © 25

Outline RAID Taxonomy

• Redundant Array of Inexpensive Independent Disks • Constructed by UC-Berkeley researchers in late 80s (Garth) • Using multiple disks • RAID 0 – Coarse-grained Striping with no redundancy • Why have multiple disks? • RAID 1 – Mirroring of independent disks • RAID 2 – Fine-grained data striping plus Hamming code disks • problem and approaches • Uses Hamming codes to detect and correct multiple errors • Originally implemented when drives didn’t always detect errors • Not used in real systems • RAID levels and performance • RAID 3 – Fine-grained data striping plus parity disk • RAID 4 – Coarse-grained data striping plus parity disk • RAID 5 – Coarse-grained data striping plus striped parity • Estimating availability • RAID 6 – Coarse-grained data striping plus 2 striped codes

21 22

RAID-0: Striping RAID-0: Striping

• Stripe blocks across disks in a chunk size • How to pick a reasonable chunk size? 0 4 1 5 2 6 3 7

8 12 9 13 10 14 11 15 0 4 1 5 2 6 3 7

8 12 9 13 10 14 11 15 • Evaluate for D disks • Capacity: How much space is wasted?

How to calculate where chunk # lives? • Performance: How much faster than 1 disk? Disk: Offset within disk: • Reliability: More or less reliable than 1 disk?

4 3/4/14

RAID-1: Mirroring RAID-4: Parity

• Motivation: Handle disk failures • Motivation: Improve capacity • Put copy (mirror or replica) of each chunk on another disk • Idea: Allocate parity block to encode info about blocks • Parity checks all other blocks in stripe across other disks • Parity block = XOR over others (gives even parity) • Example: 0 1 0 ! Parity value? 0 2 0 2 1 3 1 3 • How do you recover from a failed disk? • Example: x 0 0 and parity of 1 4 6 4 6 5 7 5 7 • What is the failed value?

Capacity: Reliability: 0! 3! 1! 4! 2! 5! P0! P1!

Performance: 6! 9! 7! 10! 8! 11! P2! P3!

RAID-4: Parity RAID-5: Rotated Parity

Rotate location of parity across all disks 0! 3! 1! 4! 2! 5! P0! P1!

6! 9! 7! 10! 8! 11! P2! P3! 0! 3! 1! 4! 2! P1! P0! 5!

6! P3! P2! 9! 7! 10! 8! 11! • Capacity: • Reliability: • Performance: • Capacity: • Reads • Writes: How to update parity block? • Reliability: • Two different approaches • Performance: • Small number of disks (or large write): • Large number of disks (or small write): • Reads: • Parity disk is the bottleneck • Writes: • Still requires 4 I/Os per write, but not always to same parity disk

Comparison Advanced Issues REDUNDANT ARRAYS OF INEXPENSIVE DISKS ()15 • What happens if more than one fault? RAID-0 RAID-1 RAID-4 RAID-5 • Example: One disk fails plus latent sector error on another Capacity NN/2 N − 1 N − 1 • RAID-5 cannot handle two faults Reliability 01(for sure) 11 N • Solution: RAID-6 (e.g., RDP) Add multiple parity blocks 2 (if lucky) Throughput • Why is NVRAM useful? Sequential Read N · S (N/2) · S (N − 1) · S (N − 1) · S • Example: What if update 2, dont update P0 before power failure Sequential Write N · S (N/2) · S (N − 1) · S (N − 1) · S (or crash), and then disk 1 fails? Random Read N · RN· R (N − 1) · RN· R • NVRAM solution: Use to store blocks updated in same stripe · · 1 · N Random Write N R (N/2) R 2 R 4 R • If power failure, can replay all writes in NVRAM Latency • Software RAID solution: Perform parity scrub over entire disk Read DD D D Write DD 2D 2D 0! 3! 1! 4! 2! 5! P0! P1! Table 38.7: RAID Capacity, Reliability, and Performance 6! 9! 7! 10! 8! 11! P2! P3!

29 Because RAID-5 is basically identical to RAID-4 except in thefewcases where it is better, it has almost completely replaced RAID-4 in the market- place. The only place where it has not is in systems that know they will never perform anything other than a large write, thus avoiding the small- write problem altogether [HLM94]; in those cases, RAID-4 is sometimes used as it is slightly simpler to build.

38.8 RAID Comparison: A Summary 5 We now summarize our simplified comparison of RAID levels in Ta- ble 38.7. Note that we have omitted a number of details to simplify our analysis. For example, when writing in a mirrored system, theaverage seek time is a little higher than when writing to just a single disk, because the seek time is the max of two seeks (one on each disk). Thus, random write performance to two disks will generally be a little lessthanrandom write performance of a single disk. Also, when updating the parity disk in RAID-4/5, the first read of the old parity will likely cause afullseek and rotation, but the second write of the parity will only result in rotation. However, our comparison does capture the essential differences, and is useful for understanding tradeoffs across RAID levels. Wepresenta summary in the table below; for the latency analysis, we simply use D to represent the time that a request to a single disk would take. To conclude, if you strictly want performance and do not care about reliability, striping is obviously best. If, however, you want random I/O performance and reliability, mirroring is the best; the costyoupayisin lost capacity. If capacity and reliability are your main goals, then RAID- 5 is the winner; the cost you pay is in small-write performance. Finally, if you are always doing sequential I/O and want to maximize capacity, RAID-5 also makes the most sense.

THREE ⃝c 2014, ARPACI-DUSSEAU EASY PIECES 3/4/14

RAID 6 TheThe Disk Disk Array Array MatrixMatrix

• P+Q Redundancy • Protects against multiple failures using Reed-Solomon codes Independent Fine Striping Course Striping • Uses 2 “parity” disks • P is parity None JBOD RAID0 • Q is a second code • It’s two equations with two unknowns, just make Replication Mirroring RAID0+1 “biggerbits” RAID1 • Group bits into “nibbles” and add different coefficients to each equation (two independent equations in two unknowns) Parity Disk RAID3 RAID4 • Similar to parity striping • De-clusters both sets of parity across all drives • For small writes, requires 6 I/Os Striped Parity Gray90 RAID5 • Read old data, old parity1, old parity2 • Write new data, new parity1, new parity2

31 32

October 2010, Greg Ganger © 29

Outline Sidebar:Sidebar: AvailabilityAvailability metric metric

• Fraction Fraction of oftime time that that server server is is able able to to handle handle requests requests • Computed from MTBF and MTTR (Mean Time To Repair) • Using multiple disks  Computed from MTBF and MTTR (Mean Time To Repair) • Why have multiple disks? MTBF • problem and approaches Availability _ MTBF + MTTR

• RAID levels and performance Installed Fixed Fixed Fixed

TBF TTR TBF TTR TBF TTR • Estimating availability 1 1 2 2 3 3

Available during these 3 periods of time.

33 October 2010, Greg Ganger © 34 13

How often are failures? HowBack often to Mean are failures? Time To Data Loss How often are failures? (MTTDL)  MTBF (Mean Time Between Failures)  MTBF (Mean Time Between Failures)

• MTBF MTBF (Meandisk ~ 1,200,00 Time Between hours (~136 Failures) years, <1% per year) • MTBF MTBF (Meandisk ~ 1,200,00 Time Between hours (~136 Failures) years, <1% per year)  pretty darned good, if you believe the number  pretty darned good, if you believe the number • MTBFdisk ~ 1,200,00 hours (~136 years, <1% per year) • MTBFdisk ~ 1,200,00 hours (~136 years, <1% per year)  MTBF = mean time to first disk failure  MTBF = mean time to first disk failure • MTBFmutli-diskmutli-disk system = mean time to first disk failure • MTBFmutli-diskmutli-disk system = mean time to first disk failure   • which is MTBFdisk // (number(number ofof disks)disks) • which is MTBFdisk // (number(number ofof disks)disks) • For a striped array of 200 drives • For a striped array of 200 drives  MTBF = 136 years / 200 drives = 0.65 years  MTBF = 136 years / 200 drives = 0.65 years • MTBFarrayarray = 136 years / 200 drives = 0.65 years • MTBFarrayarray = 136 years / 200 drives = 0.65 years

October 2010, Greg Ganger © 14 October 2010, Greg Ganger © 14 35 36

6 3/4/14

Rebuild: restoring redundancy Reliability without rebuild after failure

• 200 data drives with MTBFdrive • After a drive failure • MTTDL = MTBF / 200 • data is still available for access array drive • but, a second failure is BAD

• Add 200 drives and do mirroring • So, should reconstruct the data onto a new drive

• MTBFpair = (MTBFdrive / 2) + MTBFdrive = 1.5 * MTBFdrive • on-line spares are common features of high-end disk arrays • reduce time to start rebuild • MTTDLarray = MTBFpair / 200 = MTBFdrive / 133 • must balance rebuild rate with foreground performance impact • a performance vs. reliability trade-offs • Add 50 drives, each with parity across 4 data disks

• MTBFset = (MTBFdrive / 5) + (MTBFdrive / 4) = 0.45 * MTBFdrive • How data is reconstructed

• MTTDLarray = MTBFset / 50 = MTBFdrive / 111 • Mirroring: just read good copy • Parity: read all remaining drives (including parity) and compute

37 38

Reliability consequences of adding rebuild Three modes of operation

• No data loss, if fast enough • Normal mode • That is, if first failure fixed before second one happens • everything working; maximum efficiency • New math is... • nd • MTTDLarray = MTBFfirstdrive * (1 / prob of 2 failure before repair) • some disk unavailable • ... which is MTTRdrive / MTBFseconddrive • must use degraded mode operations • For mirroring • Rebuild mode

• MTBFpair = (MTBFdrive / 2) * (MTBFdrive / MTTRdrive) • reconstructing lost disk’s contents onto spare • degraded mode operations plus competition with • For 5-disk parity-protected arrays rebuild

• MTBFset = (MTBFdrive / 5) * ((MTBFdrive / 4 )/ MTTRdrive)

39 40

Mechanics of rebuild Conclusions

• Background process • RAID turns multiple disks into a larger, faster, more • use degraded mode read to reconstruct data reliable disk • then, write it to replacement disk • RAID-0: Striping Good when performance and capacity really matter, • Implementation issues but reliability doesnt • Interference with foreground activity and controlling rate • RAID-1: Mirroring • Rebuild is important for reliability Good when reliability and write performance matter, • Foreground activity is important for performance but capacity (cost) doesnt • Using the rebuilt disk • RAID-5: Rotating Parity • For rebuilt part, reads can use replacement disk Good when capacity and cost matter or workload is • Must balance performance benefit with rebuild read-mostly interference • Good compromise choice

41

7