Intel® RAID Controller SRCU31L User's Guide

Total Page:16

File Type:pdf, Size:1020Kb

Intel® RAID Controller SRCU31L User's Guide Intel® RAID Controller SRCU31L User’s Guide Order Number: A78137-001 Disclaimer Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel® products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel® product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. † Other names and brands may be claimed as the property of others. Copyright © 2001, Intel Corporation. All Rights Reserved. Contents 1 Introduction and General Information ........................................................ 13 Intended Audience ................................................................................................................13 RAID Levels ..........................................................................................................................13 RAID 0 - Data Striping..................................................................................................13 RAID 1 - Disk Mirroring/Disk Duplexing........................................................................14 RAID 5 - Data Striping with Striped Parity....................................................................15 RAID 10 - Combination of RAID 1 and RAID 0 ............................................................16 Chaining ................................................................................................................................17 Configuring a Chaining Set Using StorCon ..................................................................17 Configuring a Chaining Set Using StorCon+ ................................................................17 Levels of Drive Hierarchy Within the Intel RAID Controller SRCU31L-A Firmware...............18 Level 1..........................................................................................................................18 Level 2..........................................................................................................................18 Level 3..........................................................................................................................18 Level 4..........................................................................................................................19 Transparency of Host Drives.................................................................................................19 Using CD-ROMs, DATs, Tapes, etc.............................................................................20 2 Getting Started.............................................................................................. 21 What is the Intel RAID Controller SRCU31L-A Firmware?....................................................21 Standard Firmware.......................................................................................................21 RAID Hardware Installation and Setup..................................................................................22 Minimum Hardware Requirements...............................................................................22 Install the Intel RAID Controller SRCU31L-A in the Intel Server Board........................22 Install a Low or High Profile Backplate to the Intel RAID Controller SRCU31L-A if needed. .........................................................................................................22 Install the Intel RAID Controller SRCU31L-A into an available PCI slot. .............22 Attach SCSI Cables .............................................................................................22 Programming the Flash Memory ..................................................................................23 Recover the Firmware in the Flash Memory........................................................23 SCSI Termination .........................................................................................................24 Termination..........................................................................................................24 Configurable SCSI Parameters ....................................................................................25 Choosing a Configuration.............................................................................................26 How many Hard Disks Should Be Integrated into the Disk Array? ......................26 What Level of Redundancy is Needed? ..............................................................26 Are Hot Fix Drives Needed? ................................................................................26 Intel RAID Controller Hardware Features.....................................................................27 Architecture Features (HW) .................................................................................27 Electrical Characteristics .....................................................................................27 Environmental Specifications...............................................................................27 Supported Hard Drive Technology ......................................................................28 Support for Non-Hard Disk Drive SCSI Devices (Non-Direct Access Devices)...29 Compatible Intel RAID Controllers.......................................................................30 Operational States of an Intel RAID Controller SRCU31L-A Firmware Disk Array ...............31 iii Operational States for RAID 5......................................................................................31 Methods for the Replacement of a Disk Drive.......................................................................33 Intel RAID Controller SRCU31L-A Quick Start......................................................................34 Make an OS Installation Diskette .................................................................................34 Install a Low Profile Backplate to the Intel RAID Controller SRCU31L-A.....................35 Install the Intel RAID Controller SRCU31L-A in the Intel Server Board........................35 Attach SCSI Cables......................................................................................................35 Use StorCon to Create a RAID Volume .......................................................................35 Set the BIOS Boot Order..............................................................................................38 Install the Operating System ........................................................................................39 Installing Windows 2000 ......................................................................................39 Installing Red Hat Linux 7.1.................................................................................40 Alternative Method to Creating an Intel RAID Controller SRCU31L-A Installation Diskette ..41 Windows NT .................................................................................................................41 Windows 2000..............................................................................................................41 SCO Unixware†............................................................................................................41 How to Use Auto Hot-Plug with SAF-TE ...............................................................................42 Setting Up Auto Hot-Plug .............................................................................................42 3 Installing Microsoft Windows NT or Windows 2000.................................. 45 Operating System Installation Procedures ............................................................................45 Pre-Installation Requirements Checklist.......................................................................45 Minimum Hardware Requirements ......................................................................45 Minimum Software Requirements........................................................................46 Installing an Operating System onto a RAID Volume or Single Disk...........................46 Windows 2000 / NT 4.0 Installation Procedures..................................................47 Installing the OS ..................................................................................................47 Installing an OS onto an IDE or SCSI Disk Drive Not Attached to the Intel RAID Controller SRCU31L-A..................................................................................48 Windows 2000 / NT 4.0 Installation Procedures..................................................48 Upgrading an OS (Windows NT 4.0 to Windows 2000) that is Currently Installed on a RAID Volume or Single Disk .................................................................49 Installation
Recommended publications
  • Copy on Write Based File Systems Performance Analysis and Implementation
    Copy On Write Based File Systems Performance Analysis And Implementation Sakis Kasampalis Kongens Lyngby 2010 IMM-MSC-2010-63 Technical University of Denmark Department Of Informatics Building 321, DK-2800 Kongens Lyngby, Denmark Phone +45 45253351, Fax +45 45882673 [email protected] www.imm.dtu.dk Abstract In this work I am focusing on Copy On Write based file systems. Copy On Write is used on modern file systems for providing (1) metadata and data consistency using transactional semantics, (2) cheap and instant backups using snapshots and clones. This thesis is divided into two main parts. The first part focuses on the design and performance of Copy On Write based file systems. Recent efforts aiming at creating a Copy On Write based file system are ZFS, Btrfs, ext3cow, Hammer, and LLFS. My work focuses only on ZFS and Btrfs, since they support the most advanced features. The main goals of ZFS and Btrfs are to offer a scalable, fault tolerant, and easy to administrate file system. I evaluate the performance and scalability of ZFS and Btrfs. The evaluation includes studying their design and testing their performance and scalability against a set of recommended file system benchmarks. Most computers are already based on multi-core and multiple processor architec- tures. Because of that, the need for using concurrent programming models has increased. Transactions can be very helpful for supporting concurrent program- ming models, which ensure that system updates are consistent. Unfortunately, the majority of operating systems and file systems either do not support trans- actions at all, or they simply do not expose them to the users.
    [Show full text]
  • VIA RAID Configurations
    VIA RAID configurations The motherboard includes a high performance IDE RAID controller integrated in the VIA VT8237R southbridge chipset. It supports RAID 0, RAID 1 and JBOD with two independent Serial ATA channels. RAID 0 (called Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup. RAID 1 (called Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive. JBOD (Spanning) stands for Just a Bunch of Disks and refers to hard disk drives that are not yet configured as a RAID set. This configuration stores the same data redundantly on multiple disks that appear as a single disk on the operating system. Spanning does not deliver any advantage over using separate disks independently and does not provide fault tolerance or other RAID performance benefits. If you use either Windows® XP or Windows® 2000 operating system (OS), copy first the RAID driver from the support CD to a floppy disk before creating RAID configurations.
    [Show full text]
  • North Star MDS Micro Disk System Double Density
    NorthSbrCompumlnc 2547 Ninth Street Berkeley, Co. 94710 MICRO-DISK SYSTEM MDS-A-D DOUBLE DENSITY Table of Contents Introduction. ..... • 2 Cautions ...... 2 Limited Hardware Warranty 3 Out of Warranty Repair .. 3 Limited Software Warranty 4 Software License ...•. 4 Parts List ........ 5 Assembly Information ••. 8 ,< Figure lA: Identification of Components 10 Assembly and Check-out Instructions 11 l System Integration .•••.... 22 , Theory of Operation ••••• 27 ! Appendix 1: Pulse Signal Detection 35 I Schematic Drawings ••.•••.• 36 -~ I ; Copyright 1978, North star Computers, Inc. MDS-D REVISION 2 25010 INTRODUCTION The North Star Micro-Disk System (MDS-A-O) is a complete floppy disk system for use with 5-100 bus computers. The system .• includes the disk controller board, one floppy disk drive, power regulation, cables, software and documentation. The software is provided on diskette and includes the North Star Disk Operating System, BASIC Language System, Monitor, and various utility programs. The system is capable of controlling up to four disk drives. Each disk drive can record 179,200 bytes of information on a diskette, thus allowing up to 716,800 bytes of on-line disk storage. Addition disk drives, AC power supplies, and cabinets are available as options If you have purchased the MDS-A-D as a kit, then first skim the entire manual. Be sure to carefully read the Assembly Information section before beginning assembly. If you have purchased the MDS-A-D in assembled form, you may skip the A Assembly section. ., CAUTIONS .- 1. Correct this document from the errata before doing anything else. 2. Do NOT insert or remove the MDS controller from the computer while the power is turned on.
    [Show full text]
  • D:\Documents and Settings\Steph
    P45D3 Platinum Series MS-7513 (v1.X) Mainboard G52-75131X1 i Copyright Notice The material in this document is the intellectual property of MICRO-STAR INTERNATIONAL. We take every care in the preparation of this document, but no guarantee is given as to the correctness of its contents. Our products are under continual improvement and we reserve the right to make changes without notice. Trademarks All trademarks are the properties of their respective owners. NVIDIA, the NVIDIA logo, DualNet, and nForce are registered trademarks or trade- marks of NVIDIA Corporation in the United States and/or other countries. AMD, Athlon™, Athlon™ XP, Thoroughbred™, and Duron™ are registered trade- marks of AMD Corporation. Intel® and Pentium® are registered trademarks of Intel Corporation. PS/2 and OS®/2 are registered trademarks of International Business Machines Corporation. Windows® 95/98/2000/NT/XP/Vista are registered trademarks of Microsoft Corporation. Netware® is a registered trademark of Novell, Inc. Award® is a registered trademark of Phoenix Technologies Ltd. AMI® is a registered trademark of American Megatrends Inc. Revision History Revision Revision History Date V1.0 First release for PCB 1.X March 2008 (P45D3 Platinum) Technical Support If a problem arises with your system and no solution can be obtained from the user’s manual, please contact your place of purchase or local distributor. Alternatively, please try the following help resources for further guidance. Visit the MSI website for FAQ, technical guide, BIOS updates, driver updates, and other information: http://global.msi.com.tw/index.php? func=faqIndex Contact our technical staff at: http://support.msi.com.tw/ ii Safety Instructions 1.
    [Show full text]
  • The Title Title: Subtitle March 2007
    sub title The Title Title: Subtitle March 2007 Copyright c 2006-2007 BSD Certification Group, Inc. Permission to use, copy, modify, and distribute this documentation for any purpose with or without fee is hereby granted, provided that the above copyright notice and this permission notice appear in all copies. THE DOCUMENTATION IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS DOCUMENTATION INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CON- SEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEG- LIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS DOCUMENTATION. NetBSD and pkgsrc are registered trademarks of the NetBSD Foundation, Inc. FreeBSD is a registered trademark of the FreeBSD Foundation. Contents Introduction vii 1 Installing and Upgrading the OS and Software 1 1.1 Recognize the installation program used by each operating system . 2 1.2 Recognize which commands are available for upgrading the operating system 6 1.3 Understand the difference between a pre-compiled binary and compiling from source . 8 1.4 Understand when it is preferable to install a pre-compiled binary and how to doso ...................................... 9 1.5 Recognize the available methods for compiling a customized binary . 10 1.6 Determine what software is installed on a system . 11 1.7 Determine which software requires upgrading . 12 1.8 Upgrade installed software . 12 1.9 Determine which software have outstanding security advisories .
    [Show full text]
  • Installing Windows NT 4.0 (Clean) on a Fasttrak/Fasttrak66ide RAID Controller
    Installing Windows NT 4.0 (Clean) on a FastTrak/FastTrak66IDE RAID Controller * READ THIS FIRST! If you have not created any arrays using your FastTrak IDE RAID Controller, STOP and setup your array/s in the FastTrak/FastTrak66 IDE RAID Controllers Bios first before creating any Dos Partition on your boot drive, or if you plan to boot with the FastTrak/FastTrak66 like you would a Standard Hard Disk Controller create a single drive array then proceed to step #1. -Setup Procedure 1.) We STRONGLY RECOMMEND that you create a Dos Partition (no larger than 4 GB in size) before installing Windows NT 4.0 with our FastTrak IDE RAID Controller card. If possible boot up with a real dos boot disk, then execute Microsoft's FDISK to partition and format the hard disk drive. This will help to eliminate potential problems during the install process. 2.) Being the Installation process by booting up the computer with CD ROM support. Change to the CD ROM Drive letter (yours may vary) by typing "D:" (without quotations) and then pressing "enter". Then type "cd I386" and then press the "enter" key. Next type (without quotations) "winnt" or "winnt /x" (if you already have the 3 startup diskettes. After the file copying process is complete, restart your computer with the NT 4.0 boot diskette labeled "Disk1 Setup Boot disk" when prompted. 3.) Proceed with the setup process until your reach the "Mass Storage Controller auto detect screen". 4.) Next a screen will appear showing a list of Mass Storage Devices (IDE Controllers, SCSI cards, Etc.) that have been recognized by the setup program.
    [Show full text]
  • Designing Disk Arrays for High Data Reliability
    Designing Disk Arrays for High Data Reliability Garth A. Gibson School of Computer Science Carnegie Mellon University 5000 Forbes Ave., Pittsbugh PA 15213 David A. Patterson Computer Science Division Electrical Engineering and Computer Sciences University of California at Berkeley Berkeley, CA 94720 hhhhhhhhhhhhhhhhhhhhhhhhhhhhh This research was funded by NSF grant MIP-8715235, NASA/DARPA grant NAG 2-591, a Computer Measurement Group fellowship, and an IBM predoctoral fellowship. 1 Proposed running head: Designing Disk Arrays for High Data Reliability Please forward communication to: Garth A. Gibson School of Computer Science Carnegie Mellon University 5000 Forbes Ave. Pittsburgh PA 15213-3890 412-268-5890 FAX 412-681-5739 [email protected] ABSTRACT Redundancy based on a parity encoding has been proposed for insuring that disk arrays provide highly reliable data. Parity-based redundancy will tolerate many independent and dependent disk failures (shared support hardware) without on-line spare disks and many more such failures with on-line spare disks. This paper explores the design of reliable, redundant disk arrays. In the context of a 70 disk strawman array, it presents and applies analytic and simulation models for the time until data is lost. It shows how to balance requirements for high data reliability against the overhead cost of redundant data, on-line spares, and on-site repair personnel in terms of an array's architecture, its component reliabilities, and its repair policies. 2 Recent advances in computing speeds can be matched by the I/O performance afforded by parallelism in striped disk arrays [12, 13, 24]. Arrays of small disks further utilize advances in the technology of the magnetic recording industry to provide cost-effective I/O systems based on disk striping [19].
    [Show full text]
  • Megaraid® 1078-Based SAS RAID Controllers User's Guide
    USER’S GUIDE MegaRAID® 1078-based SAS RAID Controllers February 2007 ® 80-00157-01 Rev. A This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation. LSI Logic products are not intended for use in life-support appliances, devices, or systems. Use of any LSI Logic product in such applications without written consent of the appropriate LSI Logic officer is prohibited. Purchase of I2C components of LSI Logic Corporation, or one of its sublicensed Associated Companies, conveys a license under the Philips I2C Patent Rights to use these components in an I2C system, provided that the system conforms to the I2C standard Specification as defined by Philips. Document 80-00157-01 Rev. A, February 2007. This document describes the current versions of the LSI Logic Corporation MegaRAID SAS RAID controllers and will remain the official reference source for all revisions/releases of these products until rescinded by an update. LSI Logic Corporation reserves the right to make changes to any products herein at any time without notice. LSI Logic does not assume any responsibility or liability arising out of the application or use of any product described herein, except as expressly agreed to in writing by LSI Logic; nor does the purchase or use of a product from LSI Logic convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Logic or third parties.
    [Show full text]
  • Disk Array Data Organizations and RAID
    Guest Lecture for 15-440 Disk Array Data Organizations and RAID October 2010, Greg Ganger © 1 Plan for today Why have multiple disks? Storage capacity, performance capacity, reliability Load distribution problem and approaches disk striping Fault tolerance replication parity-based protection “RAID” and the Disk Array Matrix Rebuild October 2010, Greg Ganger © 2 Why multi-disk systems? A single storage device may not provide enough storage capacity, performance capacity, reliability So, what is the simplest arrangement? October 2010, Greg Ganger © 3 Just a bunch of disks (JBOD) A0 B0 C0 D0 A1 B1 C1 D1 A2 B2 C2 D2 A3 B3 C3 D3 Yes, it’s a goofy name industry really does sell “JBOD enclosures” October 2010, Greg Ganger © 4 Disk Subsystem Load Balancing I/O requests are almost never evenly distributed Some data is requested more than other data Depends on the apps, usage, time, … October 2010, Greg Ganger © 5 Disk Subsystem Load Balancing I/O requests are almost never evenly distributed Some data is requested more than other data Depends on the apps, usage, time, … What is the right data-to-disk assignment policy? Common approach: Fixed data placement Your data is on disk X, period! For good reasons too: you bought it or you’re paying more … Fancy: Dynamic data placement If some of your files are accessed a lot, the admin (or even system) may separate the “hot” files across multiple disks In this scenario, entire files systems (or even files) are manually moved by the system admin to specific disks October 2010, Greg
    [Show full text]
  • 6Gb/S Megaraid SAS RAID Controllers User Guide February 2013
    6Gb/s MegaRAID® SAS RAID Controllers User Guide February 2013 41450-04, Rev. B 41450-04B 6Gb/s MegaRAID SAS RAID Controllers User Guide February 2013 Revision History Version and Date Description of Changes 41450-04, Rev. B, February 2013 Updated the environmental conditions for the RAID controllers. Updated this guide to the new template. 41450-04, Rev. A, August 2012 Added the MegaRAID SAS 9270-8i, SAS 9271-4i, SAS 9271-8i, SAS 9271-8iCC, SAS 9286-8e, SAS 9286CV-8e, and SAS 9286CV-8eCC RAID controllers. 41450-03, Rev. A, April 2012 Added the MegaRAID SAS 9265CV-8i, SAS 9266-4i, SAS 9266-8i, and SAS 9285CV-8e RAID controllers. 41450-02, Rev. E, February 2011 Added the MegaRAID SAS 9260CV-4i, SAS 9260CV-8i, SAS 9265-8i, and SAS 9285-8e RAID controllers. 41450-02, Rev. D, June 2010 Added the MegaRAID SAS 9260-16i, SAS 9280-16i4e, and SAS 9280-24i4e RAID controllers. 41450-02, Rev. C, April 2010 Put this guide in the new template. 41450-02, Rev. B, November 2009 Added the MegaRAID SAS 9240-4i, SAS 9240-8i, SAS 9261-8i, and SAS 9280-4i4e RAID controllers. 41450-02, Rev. A, July 2009 Added the MegaRAID SAS 9260-4i, SAS 9260DE-8i, SAS 9280-8e, and SAS 9280DE-8e RAID controllers. 41450-01, Rev. A, June 2009 Added the MegaRAID SAS 9260-8i RAID controller. 41450-00, Rev. A, March 2009 Initial release of this document. LSI, the LSI & Design logo, CacheCade, CacheVault, Fusion-MPT, MegaRAID, and SafeStore are trademarks or registered trademarks All other brand and product names may be trademarks of their respective companies.
    [Show full text]
  • Identify Storage Technologies and Understand RAID
    LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals IdentifyIdentify StorageStorage TechnologiesTechnologies andand UnderstandUnderstand RAIDRAID LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Lesson Overview In this lesson, you will learn: Local storage options Network storage options Redundant Array of Independent Disk (RAID) options LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Anticipatory Set List three different RAID configurations. Which of these three bus types has the fastest transfer speed? o Parallel ATA (PATA) o Serial ATA (SATA) o USB 2.0 LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Local Storage Options Local storage options can range from a simple single disk to a Redundant Array of Independent Disks (RAID). Local storage options can be broken down into bus types: o Serial Advanced Technology Attachment (SATA) o Integrated Drive Electronics (IDE, now called Parallel ATA or PATA) o Small Computer System Interface (SCSI) o Serial Attached SCSI (SAS) LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Local Storage Options SATA drives have taken the place of the tradition PATA drives. SATA have several advantages over PATA: o Reduced cable bulk and cost o Faster and more efficient data transfer o Hot-swapping technology LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Local Storage Options (continued) SAS drives have taken the place of the traditional SCSI and Ultra SCSI drives in server class machines. SAS have several
    [Show full text]
  • • RAID, an Acronym for Redundant Array of Independent Disks Was Invented to Address Problems of Disk Reliability, Cost, and Performance
    RAID • RAID, an acronym for Redundant Array of Independent Disks was invented to address problems of disk reliability, cost, and performance. • In RAID, data is stored across many disks, with extra disks added to the array to provide error correction (redundancy). • The inventors of RAID, David Patterson, Garth Gibson, and Randy Katz, provided a RAID taxonomy that has persisted for a quarter of a century, despite many efforts to redefine it. 1 RAID 0: Striped Disk Array • RAID Level 0 is also known as drive spanning – Data is written in blocks across the entire array . 2 RAID 0 • Recommended Uses: – Video/image production/edition – Any app requiring high bandwidth – Good for non-critical storage of data that needs to be accessed at high speed • Good performance on reads and writes • Simple design, easy to implement • No fault tolerance (no redundancy) • Not reliable 3 RAID 1: Mirroring • RAID Level 1, also known as disk mirroring , provides 100% redundancy, and good performance. – Two matched sets of disks contain the same data. 4 RAID 1 • Recommended Uses: – Accounting, payroll, financial – Any app requiring high reliability (mission critical storage) • For best performance, controller should be able to do concurrent reads/writes per mirrored pair • Very simple technology • Storage capacity cut in half • S/W solutions often do not allow “hot swap” • High disk overhead, high cost 5 RAID 2: Bit-level Hamming Code ECC Parity • A RAID Level 2 configuration consists of a set of data drives, and a set of Hamming code drives. – Hamming code drives provide error correction for the data drives.
    [Show full text]