Environmental Clearance to SEIAA
Total Page:16
File Type:pdf, Size:1020Kb
Environment department, Room No. 217, 2nd floor, Mantralaya, Annexe, Mumbai- 400 032. Date:July 31, 2017 To, Mr. Nimesh Shah, Supreme Construction & Developers Pvt. Ltd. at S. No. 75 Hissa No. 1A, 2A, 2B, S. No. 51 Hissa No. 1, 2, 3, 4 and S. No. 74/6 at Village Rohinjan, Taluka – Panvel, Dist – Raigad. Environment Clearance for Amendment & Expansion of EC For Residential cum Commercial Project With Subject: MMRDA Rental Housing Scheme “ARIHANT CLAN - AALISHAN” at Rohinjan, Taloja, Navi Mumbai Sir, This has reference to your communication on the above mentioned subject. The proposal was considered as per the EIA Notification - 2006, by the State Level Expert Appraisal Committee-II, Maharashtra in its th meeting and recommend the project for prior environmental clearance to SEIAA. Information submitted by you has been considered by State Level Environment Impact Assessment Authority in its 112th meetings. 2. It is noted that the proposal is considered by SEAC-II under screening category -- as per EIA Notification 2006. Brief Information of the project submitted by you is as below :- 1.Name of Project “ARIHANT CLAN - AALISHAN” 2.Type of institution Private 3.Name of Project Proponent Mr. Nimesh Shah, Supreme Construction & Developers Pvt. Ltd. Dr. D. A. Patil, Mahabal Enviro Engg. Pvt. Ltd., F-7, Road No. 21, Wagale Estate, Thane 4.Name of Consultant (W)-400604, Maharashtra 5.Type of project Residential Project, MMRDA rental Housing Project 6.New project/expansion in existing project/modernization/diversification Not applicable in existing project 7.If expansion/diversification, whether environmental clearance Expansion has been obtained for existing project S. No. 75 Hissa No. 1A, 2A, 2B, S. No. 51 Hissa No. 1, 2, 3, 4 and S. No. 74/6 at Village Rohinjan, 8.Location of the project Taluka – Panvel, Dist – Raigad. 9.Taluka Panvel 10.Village Rohinjan 11.Whether in Corporation / Village Rohinjan, Taluka – Panvel, Dist – Raigad, (MMRDA AREA) Municipal / other area Location Clearance from MMRDA dated 25.06.2009 & 04.08.2010, MMRDA’S NOC for CC dated 15.10.2013, MMRDA’s NOC dated 21.08.2015 12.IOD/IOA/Concession/Plan IOD/IOA/Concession/Plan Approval Number: Location Clearance from MMRDA dated Approval Number 25.06.2009 & 04.08.2010, MMRDA’S NOC for CC dated 15.10.2013, MMRDA’s NOC dated 21.08.2015 Approved Built-up Area: 81466.04 13.Note on the initiated work (If Construction of 15516.35 m2 area completed as against approved area of 1,14,915.84 m2 as per applicable) Prior Environmental clearance received vide letter No. SEAC-2010/CR.340/TC.2 dt. 16.10.2010. 14.LOI / NOC / IOD from MHADA/ Location Clearance from MMRDA dated 25.06.2009 & 04.08.2010, MMRDA’S NOC for CC dated Other approvals (If applicable) 15.10.2013, MMRDA’s NOC dated 21.08.2015 SEIAA Meeting No: 112 Meeting Date: July 27, 2017 ( SEIAA- STATEMENT-0000000119 ) SEIAA-MINUTES-0000000210 Shri. Anil Diggikar (Member Secretary SEIAA-EC-0000000136 Page 1 of 13 SEIAA) 15.Total Plot Area (sq. m.) 20,470 m2 16.Deductions 0 17.Net Plot area 20,470 m2 FSI area (sq. m.): 81466.04 m2 18 (a).Proposed Built-up Area (FSI & Non FSI area (sq. m.): 125957.32 m2 Non-FSI) Total BUA area (sq. m.): 2,07,423.36 m2 Approved FSI area (sq. m.): 18 (b).Approved Built up area as per Approved Non FSI area (sq. m.): DCR Date of Approval: 19.Total ground coverage (m2) 8288.30 20.Ground-coverage Percentage (%) (Note: Percentage of plot not open 40.49 to sky) 21.Estimated cost of the project 2650000000 SEIAA Meeting No: 112 Meeting Date: July 27, 2017 ( SEIAA- STATEMENT-0000000119 ) SEIAA-MINUTES-0000000210 Shri. Anil Diggikar (Member Secretary SEIAA-EC-0000000136 Page 2 of 13 SEIAA) 22.Production Details Serial Product Existing (MT/M) Proposed (MT/M) Total (MT/M) Number 1 Not applicable Not applicable Not applicable Not applicable 23.Total Water Requirement Source of water CIDCO Fresh water (CMD): 930 KLD Recycled water - 466 KLD Flushing (CMD): Recycled water - 38 KLD Gardening (CMD): Swimming pool 0 make up (Cum): Dry season: Total Water Requirement (CMD) 1396 KLD : Fire fighting - Underground water As per Fire NOC tank(CMD): Fire fighting - Overhead water As per Fire NOC tank(CMD): Excess treated water 693 KLD Source of water CIDCO Fresh water (CMD): 852 KLD Recycled water - 466 KLD Flushing (CMD): Recycled water - 0 Gardening (CMD): Swimming pool 0 make up (Cum): Wet season: Total Water Requirement (CMD) 1396 KLD : Fire fighting - Underground water As per Fire NOC tank(CMD): Fire fighting - Overhead water As per Fire NOC tank(CMD): Excess treated water 731 KLD Details of Swimming -- pool (If any) SEIAA Meeting No: 112 Meeting Date: July 27, 2017 ( SEIAA- STATEMENT-0000000119 ) SEIAA-MINUTES-0000000210 Shri. Anil Diggikar (Member Secretary SEIAA-EC-0000000136 Page 3 of 13 SEIAA) 24.Details of Total water consumed Particula Consumption (CMD) Loss (CMD) Effluent (CMD) rs Water Require Existing Proposed Total Existing Proposed Total Existing Proposed Total ment Not Not Not Not Not Not Not Not Not Domestic applicable applicable applicable applicable applicable applicable applicable applicable applicable Level of the Ground 7-8 m water table: Size and no of RWH tank(s) and 2 rainwater storage tank of capacity 160 m3 will be provided Quantity: Location of the RWH Underground tank(s): Quantity of recharge 25.Rain Water Nil Harvesting pits: (RWH) Size of recharge pits Nil : Budgetary allocation 22 Lakhs (Capital cost) : Budgetary allocation 2 lakhs/year (O & M cost) : Details of UGT tanks UG Tanks will be provided as per NBC if any : Natural water Total SW generated will be collected through road side SWD drainage pattern: 26.Storm water Quantity of storm 1537.25 m3/hr drainage water: Size of SWD: 0.3 x 0.4 m, 0.45 X 0.50 m, 0.6 x 0.9m Sewage generation 1209 KLD in KLD: STP technology: MBBR Capacity of STP 2 STP of total Capacity 1300 m3 (CMD): 27.Sewage and Location & area of On ground Waste water the STP: Budgetary allocation 260 Lakhs (Capital cost): Budgetary allocation 55 lakhs/year (O & M cost): SEIAA Meeting No: 112 Meeting Date: July 27, 2017 ( SEIAA- STATEMENT-0000000119 ) SEIAA-MINUTES-0000000210 Shri. Anil Diggikar (Member Secretary SEIAA-EC-0000000136 Page 4 of 13 SEIAA) 28.Solid waste Management Construction material during construction phase 5990 m3, Excavation Waste generation: Waste generation in quantity: 18337.5 m3 the Pre Construction and Construction Disposal of the The construction debris and excavated material will be used at site for phase: construction waste site formation. The excavated material will be disposed as per district debris: collector/MMRDA directions. Dry waste: 2067.2 kg/day Wet waste: 3100.8 kg/day Hazardous waste: NA Waste generation Biomedical waste (If in the operation NA Phase: applicable): STP Sludge (Dry 13 KLD sludge): Others if any: -- Dry waste: Dry garbage will be segregated & disposed off to recyclers Wet garbage will be composted using Mechanical Composting system Wet waste: (Eco Biocompack) and used as organic manure for landscaping. Hazardous waste: NA Mode of Disposal Biomedical waste (If of waste: NA applicable): STP Sludge (Dry Sludge will be used as manure for gardening sludge): Others if any: -- Location(s): Ground Area Area for the storage of waste & other 180 m2 requirement: material: Area for machinery: 96 m2 Budgetary allocation Capital cost: 90 Lakhs (Capital cost and O&M cost): O & M cost: 30 lakhs/year SEIAA Meeting No: 112 Meeting Date: July 27, 2017 ( SEIAA- STATEMENT-0000000119 ) SEIAA-MINUTES-0000000210 Shri. Anil Diggikar (Member Secretary SEIAA-EC-0000000136 Page 5 of 13 SEIAA) 29.Effluent Charecterestics Serial Inlet Effluent Outlet Effluent Effluent discharge Parameters Unit Number Charecterestics Charecterestics standards (MPCB) Not 1 Not applicable Not applicable Not applicable Not applicable applicable Amount of effluent generation Not applicable (CMD): Capacity of the ETP: Not applicable Amount of treated effluent Not applicable recycled : Amount of water send to the CETP: Not applicable Membership of CETP (if require): Not applicable Note on ETP technology to be used Not applicable Disposal of the ETP sludge Not applicable SEIAA Meeting No: 112 Meeting Date: July 27, 2017 ( SEIAA- STATEMENT-0000000119 ) SEIAA-MINUTES-0000000210 Shri. Anil Diggikar (Member Secretary SEIAA-EC-0000000136 Page 6 of 13 SEIAA) 30.Hazardous Waste Details Serial Description Cat UOM Existing Proposed Total Method of Disposal Number Not Not Not Not Not 1 Not applicable Not applicable applicable applicable applicable applicable applicable 31.Stacks emission Details Height Internal Serial Fuel Used with from Temp. of Exhaust Section & units Stack No. diameter Number Quantity ground Gases (m) level (m) Not Not Not 1 Not applicable Not applicable Not applicable applicable applicable applicable 32.Details of Fuel to be used Serial Type of Fuel Existing Proposed Total Number 1 Not applicable Not applicable Not applicable Not applicable 33.Source of Fuel Not applicable 34.Mode of Transportation of fuel to site Not applicable 35.Energy Source of power MSEDCL supply : During Construction Phase: (Demand 500 kVA Load) DG set as Power back-up during 500 KVA construction phase During Operation phase (Connected 9.56 MW load): Power During Operation requirement: phase (Demand 5.85 MW load): Transformer: -- DG set as Power back-up during Sale: 2 x 750 kVA Rental: 1 x 330 kVA operation phase: Fuel used: High Speed Diesel Details of high tension line passing No through the plot if any: Energy saving by non-conventional method: • Solar lighting on street and RG area, • Solar Hot water system to buildings 36.Detail calculations & % of saving: Serial Energy Conservation Measures Saving % Number SEIAA Meeting No: 112 Meeting Date: July 27, 2017 ( SEIAA- STATEMENT-0000000119 ) SEIAA-MINUTES-0000000210 Shri.