SFF-TA-1009 Rev 3.0

Total Page:16

File Type:pdf, Size:1020Kb

Load more

Published SFF-TA-1009 Rev 3.0 SFF-TA-1009 Specification for Enterprise and Datacenter Standard Form Factor Pin and Signal Specification Rev 3.0 March 19, 2021 SECRETARIAT: SFF TA TWG This specification is made available for public review at https://www.snia.org/sff/specifications. Comments may be submitted at https://www.snia.org/feedback. Comments received will be considered for inclusion in future revisions of this specification. This specification provides a common reference for host systems manufacturers, host system integrators, and device suppliers. This specification originates from Enterprise and Datacenter SSD Form Factor Working Group (EDSFF). With non-SSD devices also using EDSFF and agreement from the EDSFF Working Group, the SFF TA TWG changed EDSFF to Enterprise and Datacenter Standard Form Factor. The description of the details in this specification does not assure that the specific component is available from device suppliers. If such a device is supplied it shall comply with this specification to achieve interoperability between device suppliers. ABSTRACT: This specification defines the pin list and pin placement, function of the pins, device specific electrical requirements, and specific features of enterprise and datacenter-based devices. This specification relies on SFF-TA-1002 for the connector mechanicals and SFF-TA-1006, SFF-TA-1007, and SFF-TA- 1008 form factor specifications for the form factor mechanicals. POINTS OF CONTACT: Anthony Constantine Chairman SFF TA TWG Intel Corporation Email: [email protected] 2111 NE 25th Ave, MS JF5-270 Hillsboro, OR 97124 Ph: 971 215 1128 Email: [email protected] Enterprise and Datacenter Standard Form Factor Pin and Signal Specification Page 1 Copyright © 2021 SNIA. All rights reserved. Published SFF-TA-1009 Rev 3.0 Intellectual Property The user's attention is called to the possibility that implementation of this specification may require the use of an invention covered by patent rights. By distribution of this specification, no position is taken with respect to the validity of a claim or claims or of any patent rights in connection therewith. This specification is considered SNIA Architecture and is covered by the SNIA IP Policy and as a result goes through a request for disclosure when it is published. Additional information can be found at the following locations: • Results of IP Disclosures: https://www.snia.org/sffdisclosures • SNIA IP Policy: https://www.snia.org/ippolicy Copyright The SNIA hereby grants permission for individuals to use this document for personal use only, and for corporations and other business entities to use this document for internal use only (including internal copying, distribution, and display) provided that: 1. Any text, diagram, chart, table or definition reproduced shall be reproduced in its entirety with no alteration, and, 2. Any document, printed or electronic, in which material from this document (or any portion hereof) is reproduced shall acknowledge the SNIA copyright on that material, and shall credit the SNIA for granting permission for its reuse. Other than as explicitly provided above, there may be no commercial use of this document, or sale of any part, or this entire document, or distribution of this document to third parties. All rights not explicitly granted are expressly reserved to SNIA. Permission to use this document for purposes other than those enumerated (Exception) above may be requested by e-mailing [email protected]. Please include the identity of the requesting individual and/or company and a brief description of the purpose, nature, and scope of the requested use. Permission for the Exception shall not be unreasonably withheld. It can be assumed permission is granted if the Exception request is not acknowledged within ten (10) business days of SNIA's receipt. Any denial of permission for the Exception shall include an explanation of such refusal. Disclaimer The information contained in this publication is subject to change without notice. The SNIA makes no warranty of any kind with regard to this specification, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The SNIA shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this specification. Suggestions for revisions should be directed to https://www.snia.org/feedback/. Enterprise and Datacenter Standard Form Factor Pin and Signal Specification Page 2 Copyright © 2021 SNIA. All rights reserved. Published SFF-TA-1009 Rev 3.0 Foreword The development work on this specification was done by the SNIA SFF TWG, an industry group. Since its formation as the SFF Committee in August 1990, the membership has included a mix of companies which are leaders across the industry. For those who wish to participate in the activities of the SFF TWG, the signup for membership can be found at https://www.snia.org/sff/join. Revision History Rev 1.0 March 23, 2018: - Initial release Rev 2.0 May 22, 2018: - Change to TX/RX ordering and changed table orientation for tables 4-4, 4-5, and 4-6. - Clarification to power sequencing requirements (section 5.2). - Update to unused reference clock guidance (section 4.2.2). - Minor editorial and formatting changes throughout document. Rev 3.0 March 19, 2021: - Name change to Enterprise and Datacenter Standard Form Factor - Revised to new format used in SFF - Updated Revision of reference documents - Editorial cleanup throughout document - Minor clarifications made throughout document - Power and Grounds: Additional requirements and expectations added to power sequencing - PCIe signals: Clarifications made to PCIe single port mode below x4 - CLKREQ: Clarifications made to CLKREQ# and PERST1# behavior in relation to DUALPORTEN# - Addition of Pull-up/Pull-down locations and values to signals requiring Pull-up/Pull-down - SMBus: Clarification on device and host pull-ups - SMBRST#: Clarifications made to SMBRST behavior - DUALPORTEN#: Replaced table on dual port vs. single port usage with simpler definition - LED/ACTIVITY: ACTIVITY portion removed. Spec will no longer support the use of ACTIVITY - Errata fix in tables 4-4, 4-5, and 4-6 to rename LED#/Activity to LED to match functional definition along with title of these tables. Changed 3.3 VAux to 3.3 Vaux - 12V supply requirements: Added new requirements for Max sustained power, Initial power, max power, and slew rate - 3.3 Vaux supply requirements: Clarified measurement time for current. - Timing requirements: Added specs for SMBRST#, PWRDIS de-assertion time and PERST to 12V power - 3.3V Logic signaling: Added SMBus to signals covered and its operating voltage, a new Vil for LEDs, updated leakage currents, and added notes. - Added Amber/Blue LED for SFF-TA-1008 along with description, values, and example schematics - LED Requirements: relaxed wavelength and point intensity ranges - Clarified Amber LED usage for SFF-TA-1006 and SFF-TA-1007 - Section 8 added for Electrical Requirements including S-parameters and eye masks Enterprise and Datacenter Standard Form Factor Pin and Signal Specification Page 3 Copyright © 2021 SNIA. All rights reserved. Published SFF-TA-1009 Rev 3.0 - Contents 1. Scope 6 1.1 Application Specific Criteria 6 2. References and Conventions 6 2.1 Industry Documents 6 2.2 Sources 6 2.3 Conventions 7 3. Keywords, Acronyms, and Definitions 8 3.1 Keywords 8 3.2 Acronyms and Abbreviations 8 3.3 Definitions 9 4. General Description 10 5. Signal List 11 5.1 Power and Grounds 12 5.2 PCIe Signals 13 5.2.1 High Speed Signals (PERp/n, PETp/n) 13 5.2.2 Reference Clock 14 5.2.3 PERST# 15 5.2.4 CLKREQ# 15 5.3 Sideband Signals 15 5.3.1 PRSNT[0..2]# 15 5.3.2 SMBus Interface 15 5.3.3 SMBRST# 16 5.3.4 DUALPORTEN# 16 5.3.5 LED 16 5.3.6 PWRDIS 16 5.3.7 MFG 16 5.3.8 RFU 17 5.4 Connector pinout definitions 17 6. Electrical Requirements 23 6.1 Power Supply Requirements 23 6.2 Timings 24 6.3 3.3 V Logic Signal Requirements 24 7. LEDs 26 7.1 Green LED 26 7.2 Amber LED (SFF-TA-1006 and SFF-TA-1007) 26 7.3 Amber/Blue LED (SFF-TA-1008) 26 8. PCIe Electrical Requirements 28 8.1 Signal Integrity Requirements 28 8.1.1 Insertion Loss (IL) 29 8.1.2 Return Loss (RL) 29 8.1.3 Power Sum Near End Crosstalk (PSNEXT) 29 8.1.4 Power Sum Far End Crosstalk (PSFEXT) 30 8.2 Transmitter and Receiver Sensitivity Eye Limits 31 8.2.1 EDSFF Device Transmitter Eye Mask 31 8.2.2 EDSFF Host Transmitter Eye Mask 31 8.2.3 EDSFF Device Receiver Minimum Sensitivity 32 8.2.4 EDSFF Host Receiver Minimum Sensitivity 32 8.3 Test Fixtures 32 Enterprise and Datacenter Standard Form Factor Pin and Signal Specification Page 4 Copyright © 2021 SNIA. All rights reserved. Published SFF-TA-1009 Rev 3.0 Figures Figure 5-1. PET and PER Signal Connectivity Between Host and Device 13 Figure 6-1. EDSFF Device Timing Diagram for PWRDIS 24 Figure 7-1. Example Schematic for Controlling the Blue/Amber LED (Common Cathode) 27 Figure 7-2. Example Schematic for Controlling the Blue/Amber LED (Common Anode) 27 Figure 8-1. EDSFF Electrical Requirements Coverage 28 Figure 8-2. Example of Circuit Contributions to Insertion Loss and Return Loss 29 Figure 8-3. Example of PSNEXT Test Configuration for Device 30 Figure 8-4. Example of PSFEXT Victim and Aggressors 30 Figure 8-5. Eye Diagram for EDSFF Device Transmitter 31 Figure 8-6. Eye Diagram for EDSFF Host Transmitter 31 Tables Table 5-1. EDSFF Connector Pin List 11 Table 5-2.
Recommended publications
  • Allgemeines Abkürzungsverzeichnis

    Allgemeines Abkürzungsverzeichnis

    Allgemeines Abkürzungsverzeichnis L.
  • Dell EMC Poweredge T340 Technical Guide

    Dell EMC Poweredge T340 Technical Guide

    Dell EMC PowerEdge T340 Technical Guide Regulatory Model: E60S Regulatory Type: E60S001 Dec. 2020 Rev. A07 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2018 - 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. 1 Product Overview Topics: • Introduction • New technologies Introduction The Dell EMC PowerEdge T340 is the reliable, easy to manage, and scalable 1-socket tower server for growing businesses and remote offices/ branch offices. New technologies The PowerEdge T340 equipped with Intel® Xeon® E-2100 and E-2200 product family processors support to help run applications faster and support for full-feature remote management (iDRAC9). The T340 is versatile enough to address many customer segments and workloads. Target workloads include ● Small and medium businesses and organizations: Collaboration/sharing productivity applications, databases, web serving, backup/recovery, and mail and messaging. ● ROBO: Applications and workloads specific to the particular industry, e.g. Retail, Healthcare, Finance, Education, etc. The following table shows the list of new technologies offered by the PowerEdge T340: New Technologies Detailed Descriptions Intel® C246 series chipset Please refer to the chipset section for details. Intel® Xeon® processor E- 2100 and E-2200 Product The Intel® processor that works with Intel® C246 series Family chipset.
  • 3. System Management Bus

    3. System Management Bus

    Input/Output Systems and Peripheral Devices 1 3. SYSTEM MANAGEMENT BUS This laboratory work presents the System Management Bus (SMBus). After an over- view of SMBus, bit and data transfers are described, the bus arbitration procedure is present- ed, the differences between SMBus and the I2C bus are highlighted, and several command protocols are detailed. Next, the Intel SMBus controller is presented, including its registers and commands, as well as its use with I2C devices. The applications aim to detect the devices connected to the computer’s SMBus, read the contents of SPD memories present in the sys- tem, and decode the contents of these memories. 3.1. Overview of SMBus System Management Bus (SMBus) is a simple serial bus with only two signal lines. This bus can be used for communication between various system devices and between these devices and the rest of a system. The operating principles of SMBus are similar to those of the I2C bus. There are, however, several differences between the two buses, differences which will be presented later. SMBus represents a control bus for system management and power management op- erations. A system may use the SMBus to transfer messages to and from various devices in- stead of using individual control lines, which allows to reduce pin count and interconnection wires. A device may use the SMBus to provide manufacturer information, provide the device model number, report different types of errors, accept control parameters, and return the de- vice status. SMBus was initially proposed by Intel as a link between an intelligent battery, a charger for the battery and a microcontroller that communicates with the rest of the system.
  • EPC612D8A-TB EPC612D8A EPC612D8 User Manual

    EPC612D8A-TB EPC612D8A EPC612D8 User Manual

    EPC612D8A-TB EPC612D8A EPC612D8 User Manual Version 1.1 Published August 2016 Copyright©2016 ASRock Rack INC. All rights reserved. Version 1.1 Published October 2016 Copyright©2016 ASRock Rack Inc. All rights reserved. Copyright Notice: No part of this documentation may be reproduced, transcribed, transmitted, or translated in any language, in any form or by any means, except duplication of documentation by the purchaser for backup purpose, without written consent of ASRock Rack Inc. Products and corporate names appearing in this documentation may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners’ benefit, without intent to infringe. Disclaimer: Specifications and information contained in this documentation are furnished for informational use only and subject to change without notice, and should not be constructed as a commitment by ASRock Rack. ASRock Rack assumes no responsibility for any errors or omissions that may appear in this documentation. With respect to the contents of this documentation, ASRock Rack does not provide warranty of any kind, either expressed or implied, including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose. In no event shall ASRock Rack, its directors, officers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of data, interruption of business and the like), even if ASRock Rack has been advised of the possibility of such damages arising from any defect or error in the documentation or product.
  • SBIR Program Document

    SBIR Program Document

    Topic Index and Description A20-101 Continuous Flow Recrystallization of Energetic Nitramines A20-102 Deep Neural Network Learning Based Tools for Embedded Systems Under Side Channel Attacks A20-103 Beyond Li-Ion Batteries in Electric Vehicles (EV) A20-104 Wireless Power transfer A20-105 Direct Wall Shear Stress Measurement for Rotor Blades A20-106 Electronically-Tunable, Low Loss Microwave Thin-film Ferroelectric Phase-Shifter A20-107 Automated Imagery Annotation and Segmentation for Military Tactical Objects A20-108 Multi-Solution Precision Location Determination System to be Operational in a Global Positioning System (GPS) Denied Environment for Static, Dynamic and Autonomous Systems under Test A20-109 Environmentally Adaptive Free-Space Optical Communication A20-110 Localized High Bandwidth Wireless Secure Mesh Network A20-111 Non-Destructive Evaluation of Bonded Interface of Cold Spray Additive Repair A20-112 Compact, High Performance Engines for Air Launched Effects UAS A20-113 Optical Based Health Usage and Monitoring System (HUMS) A20-114 3-D Microfabrication for In-Plane Optical MEMS Inertial Sensors A20-115 Using Artificial Intelligence to Optimize Missile Sustainment Trade-offs A20-116 Distributed Beamforming for Non-Developmental Waveforms A20-117 Lens Antennas for Resilient Satellite Communications (SATCOM) on Ground Tactical Vehicles A20-118 Novel, Low SWaP-C Unattended Ground Sensors for Relevant SA in A2AD Environments A20-119 Efficient Near Field Charge Transfer Mediated Infrared Detectors A20-120 Very Small Pixel Uncooled
  • Dell EMC Poweredge C4140 Technical Guide

    Dell EMC Poweredge C4140 Technical Guide

    Dell EMC PowerEdge C4140 Technical Guide Regulatory Model: E53S Series Regulatory Type: E53S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2017 - 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. 2019 - 09 Rev. A00 Contents 1 System overview ......................................................................................................................... 5 Introduction............................................................................................................................................................................ 5 New technologies.................................................................................................................................................................. 5 2 System features...........................................................................................................................7 Specifications......................................................................................................................................................................... 7 Product comparison.............................................................................................................................................................
  • System Management Bus (Smbus) Specification Version 2.0

    System Management Bus (Smbus) Specification Version 2.0

    System Management Bus (SMBus) Specification Version 2.0 System Management Bus (SMBus) Specification Version 2.0 August 3, 2000 SBS Implementers Forum Copyright 1994, 1995, 1998, 2000 Duracell, Inc., Energizer Power Systems, Inc., Fujitsu, Ltd., Intel Corporation, Linear Technology Inc., Maxim Integrated Products, Mitsubishi Electric Semiconductor Company, PowerSmart, Inc., Toshiba Battery Co. Ltd., Unitrode Corporation, USAR Systems, Inc. All rights reserved. SBS Implementers Forum 1 System Management Bus (SMBus) Specification Version 2.0 THIS SPECIFICATION IS PROVIDED “AS IS” WITH NO WARRANTIES WHATSOEVER, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY, NONINFRINGEMENT OR FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY WARRANTY OTHERWISE ARISING OUT OF ANY PROPOSAL, SPECIFICATION OR SAMPLE. IN NO EVENT WILL ANY SPECIFICATION CO-OWNER BE LIABLE TO ANY OTHER PARTY FOR ANY LOSS OF PROFITS, LOSS OF USE, INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SPECIAL DAMAGES ARISING OUT OF THIS SPECIFICATION, WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. FURTHER, NO WARRANTY OR REPRESENTATION IS MADE OR IMPLIED RELATIVE TO FREEDOM FROM INFRINGEMENT OF ANY THIRD PARTY PATENTS WHEN PRACTICING THE SPECIFICATION. * Other product and corporate names may be trademarks of other companies and are used only for explanation and to the owner’s benefit, without intent to infringe. Revision No. Date Notes 1.0 2/15/95 General Release 1.1 12/11/98 Version 1.1 Release 2.0 8/3/00 Version 2.0 Release Questions and comments regarding this For additional information on Smart specification may be forwarded to: Battery System Specifications, visit the [email protected] SBS Implementer’s Forum (SBS-IF) at: www.sbs-forum.org SBS Implementers Forum 2 System Management Bus (SMBus) Specification Version 2.0 Table of Contents 1.
  • Hello, and Welcome to This Presentation of the STM32 I²C Interface

    Hello, and Welcome to This Presentation of the STM32 I²C Interface

    Hello, and welcome to this presentation of the STM32 I²C interface. It covers the main features of this communication interface, which is widely used to connect devices such as microcontrollers, sensors, and serial interface memories. 1 The I²C interface is compliant with the NXP I2C-bus specification and user manual, Revision 3; the SMBus System Management Bus Specification, Revision 2; and the PMBus Power System Management Protocol Specification, Revision 1.1. This peripheral provides an easy-to-use interface, with very simple software programming, and full timing flexibility. Additionally, the I²C peripheral is functional in low-power stop modes. 2 The I²C peripheral supports multi-master and slave modes. The I²C IO pins must be configured in open-drain mode. The logic high level is driven by an external pull-up. The I²C alternate functions are available on IO pins supplied by VDD, which can be from 1.71 to 3.6 volts, and on IO pins supplied by VDDIO2, which can be from 1.08 to 3.6 volts. This allows communication with external chips at voltages different from the STM32L4 main power supply. A typical use case is communication with an application processor in sensor hub applications. The IO pins support the 20 mA output drive required for Fast mode Plus. The peripheral controls all I²C bus-specific sequencing, protocol, arbitration and timing values. 7- and 10-bit addressing modes are supported, and multiple 7-bit addresses can be supported in the same 3 application. The peripheral supports slave clock stretching and clock stretching from slave can be disabled by software.
  • System Management Bus(Smbus)Specification

    System Management Bus(Smbus)Specification

    System Management Bus (SMBus) Specification Version 3.1 19 Mar 2018 www.powerSIG.org © 2018 System Management Interface Forum, Inc. – All Rights Reserved Filename: SMBus 3_1_20180319.docx Last Saved: 19 March 2018 09:31 System Management Bus (SMBus) Specification Version 3.1 This specification is provided “as is” with no warranties whatsoever, whether express, implied or statutory, including but not limited to any warranty of merchantability, non-infringement or fitness for any particular purpose, or any warranty otherwise arising out of any proposal, specification or sample. In no event will any specification co-owner be liable to any other party for any loss of profits, loss of use, incidental, consequential, indirect or special damages arising out of this specification, whether or not such party had advance notice of the possibility of such damages. Further, no warranty or representation is made or implied relative to freedom from infringement of any third party patents when practicing the specification. Other product and corporate names may be trademarks of other companies and are used only for explanation and to the owner’s benefit, without intent to infringe. Revision No. Date Notes Editor 1.0 15 Feb 1995 General Release Robert Dunstan 1.1 11 Dec 1998 Version 1.1 Release Robert Dunstan 2.0 3 Aug 2000 Version 2.0 Release Robert Dunstan 3.0 20 Dec 2014 Version 3.0 Release Robert V. White Embedded Power Labs 3.1 19 Mar 2018 Version 3.1 Release Robert V. White Embedded Power Labs Questions and comments regarding this For additional information on Smart Battery System specification may be forwarded to: Specifications, visit the SBS Implementer’s Forum [email protected] (SBS-IF) at: www.sbs-forum.org © 2018 System Management Interface Forum, Inc.
  • PCI Code and ID Assignment Specification Revision 1.11 24 Jan 2019

    PCI Code and ID Assignment Specification Revision 1.11 24 Jan 2019

    PCI Code and ID Assignment Specification Revision 1.11 24 Jan 2019 PCI CODE AND ID ASSIGNMENT SPECIFICATION, REV. 1.11 Revision Revision History Date 1.0 Initial release. 9/9/2010 1.1 Incorporated approved ECNs. 3/15/2012 1.2 Incorporated ECN for Accelerator Class code, added PI for xHCI. 3/15/2012 Updated section 1.2, Base Class 01h, Sub-class 00h by adding 1.3 9/4/2012 Programming Interfaces 11h, 12h, 13h, and 21h. Added Notes 3, 4, and 5. Updated Section 1.2, Base Class 01h, to add Sub-class 09h. Updated Section 1.9, Base Class 08h to add Root Complex Event Collector, Sub-class 07h 1.4 Updated Section 1 and added Section 1.20, to define Base Class 13h. 8/29/2013 Updated Chapter 3 to define Extended Capability IDs 001Dh through 0022h. Reformatted Notes in Sections 1.2 and 1.7 through 1.10. Updated references to NVM Express in Section 1.9, Base Class 08h Updated Section 1.2, to clarify SOP entries in Base Class 01h, add proper reference to NVMHCI, update UFS entries, and address other minor 1.5 3/6/2014 editorial issues. Updated Section 3, Extended Capability ID descriptions 19h, 1Ch, 1Fh. Updated Section 1.3, Class 02h, to add Sub-Class 08h. 1.6 Updated Section 1.14, Base Class 0Dh, to add Sub-Classes 40h and 41h. 12/9/2014 Updated Section 2 to add Capability ID 14h. Added Designated Vendor-Specific Extended Capability ID. 1.7 Updated/Modified Section 1.5, Base Class 04h, for Multimedia devices to 8/13/2015 accurately reflect use of this class for High Definition Audio (HD-A).
  • Quick Reference Guide for A1SA7-2750F

    Quick Reference Guide for A1SA7-2750F

    ONTACT NFORMATION FOR YOUR SYSTEM TO WORK PROPERLY, PLEASE DOWNLOAD APPROPRIATE R C I SUPERMICR • Website: www.supermicro.com DRIVERS/IMAGES/USER'S MANUAL FROM THE LINKS BELOW: A1SA7-2750/2550F • General Information: [email protected] • Manuals: http://www.supermicro.com/support/manuals • Technical Support: [email protected] • Drivers & Utilities: ftp://ftp.supermicro.com/CDR_Images/CDR-A1-UP/ MNL-1616-QRG QUicK REFERENCE GUIDE REV. 1.00 • Phone: +1 (408) 503-8000, Fax: +1 (408) 503-8008 • Safety: http://www.supermicro.com/about/policies/safety_information.cfm Motherboard Layout and Features Jumpers, Connectors and LED Indicators Memory Support Jumpers The A1SA7-2750/2550F motherboard supports up to 64GB of DDR3 ECC or Non- Jumper Item # Description Default ECC Unbuffered (UDIMM) 1600/1333 MHz in x8 data width only, in 4 memory slots. 19 1 JBT1 30 CMOS Clear Open: Normal Operation, Short: Clear CMOS 110 18 17 6 Populating these DIMM modules with a pair of memory modules of the same type 1 14 13 5 12 11 JI2C1/JI2C2 40, 41 SMB to PCI-Exp. Slots Off (Disabled) 461 and same size will result in better memory performance. 451 2 LED8 LED7 JPG1 11 VGA Enable Pins 1-2 (Enabled) JUIDB1 VGA UID-LE DIMM Memory Installation J28 JPG1 JPL1 36 Ethernet LAN Ports Enable Pins 1-2 (Enabled) UID-SW SW1 USB1 J27 USB2 111 D USB1/0 JWD1 43 Watch Dog Enable Pins 1-2 (Reset) Towards the edge of motherboard BMC IPMI_LAN LAN2 LAN1 L-SAS1 L-SAS1 AST2400 Connectors 1 DIMMA1 (Blue Slot) JPL1 I-SATA0 35 Connector Item # Description 4 5 411 JI2C JI2C 401
  • Intel® Omni-Path Software — Release Notes for V10.8.0.2

    Intel® Omni-Path Software — Release Notes for V10.8.0.2

    Intel® Omni-Path Software Release Notes for V10.8.0.2 Rev. 1.0 January 2019 Doc. No.: K48500, Rev.: 1.0 You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein. No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document. All information provided here is subject to change without notice. Contact your Intel representative to obtain the latest Intel product specifications and roadmaps. The products described may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Intel technologies’ features and benefits depend on system configuration and may require enabled hardware, software or service activation. Performance varies depending on system configuration. No computer system can be absolutely secure. Check with your system manufacturer or retailer or learn more at intel.com. Intel, the Intel logo, Intel Xeon Phi, and Xeon are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. Copyright © 2019, Intel Corporation. All rights reserved. Intel® Omni-Path Software Release Notes for V10.8.0.2 January 2019 2 Doc. No.: K48500, Rev.: 1.0 Contents—Intel® Omni-Path Fabric Contents 1.0 Overview of the Release............................................................................................... 5 1.1 Important Information...........................................................................................