1123 Ultra-compact Collimated Beam Sensor HL-T1 SERIES ■■General terms and conditions...... F-7 ■■Sensor selection guide...... P.1055~ FIBER Related Information SENSORS ■■Glossary of terms / General precautions...... P.1493 / P.1501 ■■About laser beam...... P.1499~ LASER SENSORS

PHOTOELECTRIC SENSORS Conforming to Conforming to FDA regulations EMC Directive MICRO (HL-T□F only) PHOTOELECTRIC SENSORS AREA SENSORS CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS

SENSOR OPTIONS This product is classified as a SIMPLE Class 1 Laser Product in IEC / WIRE-SAVING JIS standards and a Class II UNITS Laser Product in FDA regulations WIRE-SAVING 21 CFR 1040.10. Do not look at SYSTEMS the laser beam through optical MEASUREMENT system such as a . SENSORS panasonic.net/id/pidsx/global STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS Ultra-compact sensor head A high-functionality

PLC intelligent controller

HUMAN MACHINE INTERFACES Ultra-compact sensor head Resolution of 4 µm 0.157 mil ENERGY CONSUMPTION VISUALIZATION COMPONENTS The ultra-compact size and yet the high level of performance. A high resolution of 4 μm 0.157 mil (at an average These sensors save space. 64 cycles) allows high-precision positioning and size FA COMPONENTS HL-T1001A(F) HL-T1010A(F) judgment. HL-T1005A(F) MACHINE VISION Emitter Emitter Distinguishing size of SYSTEMS 34 mm 1.339 in electronic components UV CURING 15mm 0.591 in SYSTEMS 20 mm 0.787 in 42 mm 15 mm 0.591 in 1.654 in 20 mm 0.7487 in 15 mm 19 mm 0.748 in 20 mm 0.591 in 0.787 in 25 mm 15 mm 0.591 in 0.984 in 20 mm 0.787 in

Selection Receiver Receiver Guide Laser Displacement Magnetic Displacement BASIC PERFORMANCE Collimated Beam Digital Panel Long sensing range Minimum sensing object Controller diameter ø8 µm ø0.315 mil HL-T1001A(F) Metal-sheet Long sensing range of 500 mm 19.685 in Double-feed Detection [HL-T1005A(F), HL-T1010A(F)] and 2 m 6.562 ft The laser with a beam [HL-T1001A(F)] are available. diameter of ø1 mm HL-T1 ø0.039 in can sense LA High-precision judgment even from extremely small objects with dimensions in LD minute differences in light intensity micrometers such as The sensors are sensitive Distinguishing opacity of glass bonding wires. to minute differences in light intensity, so that they can judge even the opacity of glass. Adoption of a Class 1 laser In addition, the amount of light received can be The adoption of a Class 1 laser (IEC / JIS) eliminates the displayed as a percentage need for safety countermeasures, so that these sensors to allow you to determine can be used in photoelectric sensor applications with permeation rates. confidence. Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES 1124

APPLICATIONS FIBER SENSORS

LASER Checking the positioning of chip components Detecting defective lead frame seating Sensing wafer position in wafer cassette SENSORS

PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR FUNCTIONS USE SENSORS Fully equipped with convenient functionality Analog output is switchable between current / voltage SENSOR OPTIONS A wide range of convenient features has been incorporated The analog output can be switched between either of SIMPLE WIRE-SAVING into the unit’s compact body: standard received light setting two different outputs; current (4 to 20 mA) / voltage UNITS / auto scaling setting / measurement processing (various (±4 V). With the monitor function, the output can WIRE-SAVING timer and hold functions) / differentiation / monitor focus be adjusted over the range from –5 V to +5 V, or from SYSTEMS function. These features make the unit useful for a wide 0 V to +5 V, facilitating connectivity with a variety of MEASUREMENT variety of applications. output devices. SENSORS STATIC ELECTRICITY 3 types of teaching functions are now available Monitor focus function PREVENTION DEVICES The linear output is fully adjustable over the following 3 types of teaching functions are available: positioning LASER teaching / 2-point teaching / automatic teaching, thus range (current: 4 to 20 mA / voltage: ±4 V). The usage MARKERS enabling a variety of applications to be accommodated of the monitor focus function together with selectable PLC for many different types of production sites. current / voltage switching for the linear output allows for compatibility with a variety of output devices. The actual value measured at the time when teaching HUMAN MACHINE INTERFACES Positioning is performed is utilized as the threshold value. (Examples) teaching Best suited for high-precision positioning. ENERGY CONSUMPTION +4 VISUALIZATION In this teaching method, an intermediate level between COMPONENTS the first and the second teaching levels is utilized as 2-point the threshold value. Minute differences, such as FA COMPONENTS teaching changes as small as the thickness of a sheet of paper between the sensing objects, can be detected when MACHINE VISION this teaching method is utilized. SYSTEMS –4 With this teaching method, a series of periodic arbitrarily UV CURING measurements are taken automatically and an Linear output voltage (V) SYSTEMS intermediate value, between the maximum and minimum Automatic values obtained by this measurement, is utilized as the 0 5.0 teaching threshold value. The threshold value is therefore set in 0.197 relation to the sensing object. Best suited for Sensor display value (mm in) applications in which teaching must be performed In the event that In the event that without stopping the current flow of operations. 5 mm 0.197 in: +5 V 5 mm 0.197 in: +1 V 0 mm 0 in: +1 V 0 mm 0 in: +5 V Selection Detection resolution can be easily confirmed Guide Laser The current resolution can be easily confirmed by setting Displacement +5 +5 Magnetic the controller to indicate resolution display mode. Displacement By displaying the resolution, the marginal increment can Collimated Beam be easily determined for the threshold value setting, Digital Panel Controller helping to accurately determine whether sensing can be +1 +1 Metal-sheet performed. Resolution Double-feed Detection

indicator Linear output voltage (V) Linear output voltage (V) 0 5.0 0 5.0 0.197 0.197 Sensor display value (mm in) Sensor display value (mm in) HL-T1 The linear output must be set by determining output LA values (maximum; current: 0 to 23.5 mA / voltage: ±5.5 V) LD at two different points, for the arbitrary display value.

MAINTENANCE Self-check for deterioration The intelligent controller performs self-checking for laser Error display diode deterioration. If the controller detects significant deterioration (end of diode life), an error will be displayed on the main digital display panel. This function enables users to prepare in advance for potential laser diode malfunctions. 1125 Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES

FIBER OPERABILITY OPTIONS SENSORS

LASER Superior operability has been achieved Calculations for 2 sensors are possible SENSORS

PHOTO- All settings can be easily performed by using the four-way The calculation unit (optional) just needs to be connected ELECTRIC SENSORS keys and viewing the digital displays. between the two controllers to enable calculations (addition MICRO and subtraction) to be carried out for two sensors. No digital PHOTO- Large dual digital display ELECTRIC panel controller is needed either. SENSORS After power up, the measured value (red) and the

AREA threshold value (yellow) are displayed SENSORS (letter height 7 mm 0.276 in) LIGHT Judgment output indicators CURTAINS / Sheet width measurement SAFETY HIGH (Orange) / PASS (Green) / LOW COMPONENTS (Yellow) 3-color display PRESSURE / Calculation unit FLOW SENSORS HL-AC1-CL

INDUCTIVE PROXIMITY SENSORS

PARTICULAR USE SENSORS

SENSOR OPTIONS Easy operation with four-way keys SIMPLE WIRE-SAVING UNITS

WIRE-SAVING ORDER GUIDE SYSTEMS

MEASURE- MENT Sensor heads SENSORS STATIC ELECTRICITY Min. sensing Conforming PREVENTION Type Appearance Sensing range Sensing width Model No. DEVICES object standards / regulations LASER MARKERS ø8 µm ø0.315 mil ø1 mm ø0.039 in opaque object IEC / JIS HL-T1001A PLC ø1 to ø2.5 mm ø50 µm ø1.969 mil ø0.039 to ø0.098 in HUMAN 2 m 6.562 ft opaque object at

type at 500 to 2,000 mm MACHINE 500 to 2,000 mm INTERFACES 19.685 to 78.740 in 19.685 to 78.740 in ENERGY sensing range FDA / CONSUMPTION sensing range HL-T1001F VISUALIZATION IEC / JIS ø0.039 in COMPONENTS Beam diameter ø1 mm

FA COMPONENTS

MACHINE IEC / JIS HL-T1005A VISION SYSTEMS ø0.05 mm ø0.002 in UV 500 mm 19.685 in 5 mm 0.197 in CURING type opaque object SYSTEMS FDA / IEC / JIS HL-T1005F 0.197 in Sensing width 5 mm

IEC / JIS HL-T1010A Selection Guide Laser ø0.1 mm ø0.004 in Displacement 500 mm 19.685 in 10 mm 0.394 in

type opaque object Magnetic Displacement FDA / Collimated IEC / JIS HL-T1010F 0.394 in Beam Sensing width 10 mm Digital Panel Controller Metal-sheet Note: The model No. with “P” shown on the label affixed to the product is the emitter, “D” shown on the label is the receiver. Double-feed Detection Accessories HL-T1 • MS-HLT1-1 • MS-LA3-1 • CN-HLT1-1 (Sensor head to controller connection cable) LA Sensor mounting bracket Sensor mounting bracket for HL-T1001A(F) / LD for HL-T1010A(F) HL-T1005A(F) (Note) (Note)

Two M3 (length 20 mm 0.787 in) Two M3 (length 25 mm 0.984 in) screws with washers are attached. screws with washers are attached. Note: 2 sets are required to mount the emitter / receiver. Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES 1126

FIBER ORDER GUIDE SENSORS

LASER Controllers SENSORS

PHOTO- ELECTRIC Type Appearance Model No. Output SENSORS MICRO PHOTO- ELECTRIC SENSORS

AREA NPN open-collector transistor SENSORS (Judgment output) HL-AC1 LIGHT Current / voltage output CURTAINS / (Linear output) SAFETY NPN output COMPONENTS PRESSURE / FLOW SENSORS

INDUCTIVE PROXIMITY PNP open-collector transistor SENSORS (Judgment output) PARTICULAR HL-AC1P Current / voltage output USE SENSORS (Linear output) PNP output SENSOR OPTIONS

SIMPLE WIRE-SAVING UNITS Calculation unit WIRE-SAVING SYSTEMS Appearance Model No. MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES HL-AC1-CL LASER MARKERS

PLC

HUMAN MACHINE INTERFACES OPTIONS ENERGY CONSUMPTION VISUALIZATION COMPONENTS Side-view attachment FA COMPONENTS Designation Model No. Description • HL-T1SV1 MACHINE • HL-T1SV2 VISION SYSTEMS For HL-T1001A(F) / HL-T1SV1 T1005A(F) (1 pc.) The beam axis can be bent to a right UV Side-view CURING angle making universal mounting attachment SYSTEMS For HL-T1010A(F) possible. HL-T1SV2 (1 pc.)

Controller Use when mounting the controller with screws. mounting bracket MS-HLAC1-1

Extension cable for use between the controller Length: 4 m 13.123 ft Selection HL-T1CCJ4 Net weight: 162 g approx. and its cable linking it with the sensor head. Guide Cabtyre cable with connectors on both ends Extension cable Mounted on both sides Mounted on one side only Laser Cable outer diameter: ø5.2 mm ø0.205 in Displacement Length: 8 m 26.247 ft Connector outer diameter: Magnetic HL-T1CCJ8 Displacement Net weight: 330 g approx. ø15.5 mm ø0.610 in max. Controller mounting bracket Collimated Beam • MS-HLAC1-1 Digital Panel Controller Metal-sheet Double-feed Detection

HL-T1

LA

LD

Extension cable • HL-T1CCJ4 • HL-T1CCJ8 1127 Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES

FIBER SENSORS SPECIFICATIONS

LASER SENSORS Sensor heads

PHOTO- ELECTRIC Type Beam diameter ø1 mm ø0.039 in type Sensing width 5 mm 0.197 in type Sensing width 10 mm 0.394 in type SENSORS MICRO IEC / JIS standards conforming type HL-T1001A HL-T1005A HL-T1010A PHOTO- ELECTRIC Item FDA regulations conforming type HL-T1001F HL-T1005F HL-T1010F SENSORS Model No.

AREA Applicable controller HL-AC1, HL-AC1P SENSORS Sensing range 0 to 500 mm 0 to 19.685 in 500 to 2,000 mm 19.685 to 78.74 in 500 mm 19.685 in LIGHT CURTAINS / Sensing width ø1 mm ø0.039 in ø1 to ø2.5 mm ø0.039 to ø0.098 in 5 mm 0.197 in 10 mm 0.394 in SAFETY COMPONENTS ø8 µm ø0.315 mil ø50 µm ø1.969 mil Min. sensing object ø0.05 mm ø0.002 in opaque object ø0.1 mm ø0.004 in opaque object PRESSURE / opaque object opaque object FLOW SENSORS Repeatability 4 µm 0.157 mil – 4 µm 0.157 mil (Note 2) INDUCTIVE (During the state in which light is half blocked) (Note 2) PROXIMITY SENSORS Linear output resolution 4 µm 0.157 mil – 4 µm 0.157 mil (Note 2) PARTICULAR (Note 3) (Note 2, 4) USE SENSORS Emission indicator Green LED ( up during laser emission) SENSOR Interference prevention function Two units of sensors can be mounted close together. (When the controller interference prevention function is used) OPTIONS Pollution degree 3 (industrial environment) SIMPLE WIRE-SAVING Ambient temperature 0 to +50 °C +32 to +122 °F (No dew condensation), Storage: –25 to +70 °C –13 to +158 °F UNITS Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH WIRE-SAVING SYSTEMS Ambient illuminance Incandescent light: 10,000 ℓx at the light-receiving face EMC EN 61000-6-2, EN 61000-6-4 MEASURE- MENT SENSORS Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure STATIC Insulation resistance 100 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure ELECTRICITY PREVENTION Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each DEVICES Environmental resistance Shock resistance 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each LASER MARKERS Red semiconductor laser Class 1 (IEC / JIS) Red semiconductor laser Class 1 (IEC / JIS) IEC / JIS standards modulated, max. output: 0.2 mW, peak modulated, max. output: 0.35 mW, PLC conforming type emission wavelength: 650 nm 0.026 mil peak emission wavelength: 650 nm 0.026 mil HUMAN MACHINE INTERFACES Red semiconductor laser Class II (FDA) Red semiconductor laser Class II (FDA) ENERGY FDA regulations modulated, max. output: 0.35 mW, CONSUMPTION modulated, max. output: 0.2 mW, peak VISUALIZATION Emitting element conforming type emission wavelength: 650 nm 0.026 mil peak emission wavelength: 650 nm 0.026 mil COMPONENTS (IEC / JIS: Class 1) (IEC / JIS: Class 1) FA COMPONENTS Material Enclosure: Polyetherimide, Case cover: Polycarbonate, Front cover: Glass MACHINE Cable 0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long VISION SYSTEMS Cable extension Extension up to total 10 m 32.808 ft is possible, with the optional cable. UV Net weight Emitter: 15 g approx., Receiver: 15 g approx. Emitter: 30 g approx., Receiver: 20 g approx. CURING SYSTEMS MS-HLT1-1(Sensor head mounting bracket): One set of two brackets for both MS-LA3-1 (Sensor head mounting bracket): the emitter and the receiver One set of two brackets for both the emitter and the receiver Accessories CN-HLT1-1(Sensor head to controller connection cable): 1 cable CN-HLT1-1 (Sensor head to controller connection cable): 1 cable Laser beam alignment sticker: 2 pcs. Laser beam alignment sticker: 2 pcs. Label set (FDA regulations conforming type only): 1 set Label set (FDA regulations conforming type only): 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. Selection 2) In case of an average sampling rate of 64 times. Guide 3) Value calculated with the linear output allowance factor (±3 σ) when connected to the controller included in the calculation of the detection width. Laser Displacement 4) This value was obtained by converting the range of linear output fluctuation (±3 σ) into a sensing width, assuming that the smallest sensing object Magnetic blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in. Displacement Collimated Beam Calculation unit Digital Panel Controller Model No. Metal-sheet Double-feed HL-AC1-CL Detection Item Connected controller HL-AC1, HL-AC1P HL-T1 Current consumption 12 mA or less (supplied from the controller)

LA Connecting method Connector

LD Connection indicator Orange LED (lights up when connected to the controller) Ambient temperature 0 to +50 °C +32 to +122 °F (No dew condensation), Storage: –15 to +60 °C +5 to +140 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Voltage withstandablity 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 100 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.7 mm 0.028 in amplitude in X, Y and Z directions for 80 min.

2

Environmental resistance Shock resistance 300 m/s acceleration (30 G approx.) in X, Y and Z directions for three times each Material Enclosure: ABS, Indicator part: Acrylic Weight Net weight: 50 g approx. Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES 1128

FIBER SPECIFICATIONS SENSORS

LASER Controllers SENSORS Type NPN output PNP output PHOTO- ELECTRIC SENSORS Item Model No. HL-AC1 HL-AC1P MICRO PHOTO- Applicable sensor head HL-T1001A/T1001F, HL-T1005A/T1005F, HL-T1010A/T1010F ELECTRIC Supply voltage / Current consumption 12 to 24 V DC ± 10 % Ripple P-P 10 % or less / 190 mA or less (when connected to the sensor head) SENSORS AREA Measuring cycle 150 μs SENSORS

Current / voltage output switchable (Note 2) LIGHT • During current output: 4 to 20 mA/F.S., Maximum load resistance: 300 Ω CURTAINS / Linear output SAFETY • During voltage output: ±4 V/F.S., Output impedance 100 Ω COMPONENTS (In the monitor focus function, it can also be set at ±5 V, 0 to 5 V, etc.) PRESSURE / FLOW Temperature characteristics ±0.2 % F.S./°C (Note 3) SENSORS Settable average sampling rate (Note 4) 1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1,024 / 2,048 / 4,096 INDUCTIVE PROXIMITY NPN open-collector transistor PNP open-collector transistor SENSORS Judgment outputs • Maximum sink current: 50 mA • Maximum source current: 50 mA PARTICULAR USE (HIGH, PASS, LOW) • Applied voltage: 30 V DC or less (between judgment output and 0 V) • Applied voltage: 30 V DC or less (between judgment output and +V) SENSORS • Residual voltage: 1.2 V or less (at 50 mA sink current) • Residual voltage: 2 V or less (at 50 mA source current) SENSOR Utilization category DC-12 or DC-13 OPTIONS Number of outputs HIGH / PASS / LOW 3 values output SIMPLE WIRE-SAVING HIGH: ON when measured value > HIGH threshold value UNITS Output operation PASS: ON when HIGH threshold value ≥ measured value ≥ LOW threshold value LOW: ON when LOW threshold value > measured value WIRE-SAVING SYSTEMS Short-circuit protection Incorporated MEASURE- 0 V connection: Laser emission halt +V connection: Laser emission halt MENT SENSORS Laser OFF input Open: Laser emission Open: Laser emission STATIC • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) ELECTRICITY PREVENTION 0 V connection: Zero reset operates +V connection: Zero reset operates DEVICES Zero reset input Open: Zero reset ineffective Open: Zero reset ineffective LASER • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) MARKERS 0 V connection: Effective +V connection: Effective Timing input Open: Ineffective Open: Ineffective PLC • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) HUMAN 0 V connection: Effective +V connection: Effective MACHINE INTERFACES Reset input Open: Ineffective Open: Ineffective ENERGY • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) • Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) CONSUMPTION VISUALIZATION Laser emitting (LD ON) Green LED (lights up during laser emission) COMPONENTS HIGH: Orange LED (lights up when measured value > HIGH threshold value) FA COMPONENTS Judgment outputs PASS: Green LED (lights up when HIGH threshold value ≥ measured value ≥ LOW threshold value) LOW: Yellow LED (lights up when LOW threshold value > measured value) MACHINE VISION Indicators Enable (ENABLE) Green LED (lights up during normal operation) SYSTEMS

Zero reset (ZERO) Green LED (lights up when the zero reset function is enabled) UV CURING RUN mode: Either the measured value (mm) or the hold value will be displayed. SYSTEMS Main digital display 5 digit red LED display Reverse mode: The display orientation will be reversed.

RUN mode: Either the resolution or laser beam reception amount will be displayed. Sub-digital display 5 digit yellow LED display THR mode: The threshold value will be displayed., Reverse mode: The display orientation will be reversed. • Measured value • Display reverse • Zero reset • Positioning teaching • (A + B) calculation display • ECO display • Initial reset • 2-level teaching (Note 5) Selection • Setting value, light • Display digits limitation • ON-delay timer • Automatic teaching • Mutual interference Guide amount value • Sample hold • OFF-delay timer • Hysteresis width variablity prevention (Note 5) Laser Displacement Main functions resolution display • Peak hold • ONE SHOT timer • Monitor focus • Laser deterioration Magnetic • Standard received light • Bottom hold • Differentiation • Non-measuring time detection Displacement setting • Peak to peak hold • Sensitivity selection setting • Key lock Collimated • Automatic scaling • Self peak hold • Threshold value direct • (A – B) calculation • Zero reset memory Beam • Scaling • Self bottom hold setting (Note 5) Digital Panel Controller Pollution degree 3 (industrial environment) Metal-sheet Double-feed Ambient temperature 0 to +50 °C +32 to +122 °F (No dew condensation), Storage: –25 to +65 °C –13 to +149 °F Detection Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH EMC EN 61000-6-2, EN 61000-6-4 HL-T1 Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure LA

Insulation resistance 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure LD Vibration resistance 10 to 150 Hz frequency, 0.7 mm 0.028 in amplitude in X, Y and Z directions for 80 min.

Environmental resistance Shock resistance 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each Material Enclosure: Polybutylene terephthalate, Transparent cover: Polycarbonate I/O cable 0.09 mm2 10-core composite cable, 2 m 6.562 ft long I/O cable extension Extension up to total 10 m 32.808 ft is possible, with 0.09 mm2 or more, cable. (Note 6) Weight Net weight: 140 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) Switching between current and voltage is accomplished by a switch on the bottom of the controller. 3) These are the temperature characteristics of the linear output when the sensor head is connected. 4) The judgment output and linear output and linear output response time is calculated by (Measuring cycle) × (Set average sampling rate + 1). 5) The calculation unit is necessary. 6) If the extension cable is longer than 10 m 32.808 ft, then it will not qualify for CE marking. 1129 Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES

FIBER SENSORS I/O CIRCUIT DIAGRAMS

LASER SENSORS HL-AC1 NPN output type HL-AC1P PNP output type PHOTO- ELECTRIC Color code Color code SENSORS (Brown) +V (Brown) +V MICRO PHOTO- D (White) HIGH Tr1 D ELECTRIC Load 50 mA max. SENSORS judgment output Tr1 Load (White) HIGH judgment output AREA 50 mA max. Tr2 ZD1 Load ZD1 50 mA max. Load SENSORS Tr2 (Green) PASS judgment output + 12 to 24 V DC + 12 to 24 V DC – ±10 % (Green) PASS judgment output – ±10 % LIGHT 50 mA max. Tr3 CURTAINS / ZD2 ZD2 50 mA max. Load SAFETY Tr3 (Gray) LOW judgment output COMPONENTS 50 mA max. (Gray) LOW judgment output Load PRESSURE / ZD3 (Blue) GND (0 V) FLOW (Blue) GND (0 V) ZD3 SENSORS (Pink) LD-OFF input * 1 (Pink) LD-OFF input * 1 INDUCTIVE PROXIMITY (Violet) Timing input * 1 Main circuit (Violet) Timing input * 1 SENSORS Main circuit PARTICULAR (Orange / Violet) Zero reset input * 1 (Orange / Violet) Zero reset input * 1 USE SENSORS (Red) Reset input * 1 (Red) Reset input * 1 SENSOR OPTIONS Current output Current output 4 to 20 mA 4 to 20 mA (Black) Linear output (Black) Linear output SIMPLE Current output: Current output: WIRE-SAVING Voltage 300 Ω or less Voltage 300 Ω or less UNITS 100Ω Load 100Ω Load output ±4 V (Shield) Linear GND Voltage output: output ±4 V (Shield) Linear GND Voltage output: 10 kΩ or more WIRE-SAVING 10 kΩ or more SYSTEMS Internal circuit Users’ circuit Internal circuit Users’ circuit

MEASURE- MENT SENSORS Symbols … D: Reverse supply polarity protection diode Symbols … D: Reverse supply polarity protection diode D1, D2, D3 D1, D2, D3 STATIC Z Z Z : Surge absorption zener diode Z Z Z : Surge absorption zener diode ELECTRICITY Tr1, Tr2, Tr3: NPN output transistor Tr1, Tr2, Tr3: PNP output transistor PREVENTION DEVICES * 1 * 1 LASER MARKERS Non-voltage contact or NPN open-collector transistor Non-voltage contact or PNP open-collector transistor

PLC or or

HUMAN MACHINE • LD-OFF input, Timing input, Zero reset input, Reset input • LD-OFF input, Timing input, Zero reset input, Reset input INTERFACES Low (0 to 1.5 V): Effective Low (0 V or open): Ineffective ENERGY High (+V or open): Ineffective High [ +V to ( +V –1.5 V)]: Effective CONSUMPTION VISUALIZATION COMPONENTS

FA COMPONENTS SENSING CHARACTERISTICS (TYPICAL)

MACHINE VISION SYSTEMS HL-T1001A HL-T1001F HL-T1005A HL-T1005F UV CURING SYSTEMS Correlation between transverse Correlation between transverse Correlation between interrupted deviation and output voltage deviation and output voltage beam width and output voltage 8 8 8 Horizontal direction Vertical direction Horizontal direction Vertical direction 250 mm 9.843 in Sensing object 2 m 6.562 ft 2 m 6.562 ft Receiver Receiver 500 mm 19.685 in 500 mm 19.685 in Emitter ℓ + Receiver ) Receiver Receiver ) ) V Emitter Emitter ( V

6 ℓ ℓ Emitter Emitter V ( ℓ 6 ℓ ( 6 – 500 mm Selection 19.685 in 4 Vertical direction 4 The graph depicts the Guide Vertical direction correlation between 4 Laser transverse deviation and Displacement Horizontal direction Horizontal direction output voltage when the full-scale setting ranges Magnetic 2 The graph depicts the correlation between 2 from 0 V (light beam is Displacement transverse deviation and output voltage when interrupted) to 5 V (light 2 Linear output voltage

Linear output voltage beam is fully incident), Collimated the full-scale setting ranges from 0 V (light Linear output voltage Beam beam is interrupted) to 5 V (light beam is fully using the Monitor Focus incident), using the Monitor Focus function. function. Digital Panel 0 0 0 Controller 4 2 0 2 4 10 5 0 5 10 –10 –5 0 5 10 Metal-sheet 0.157 0.079 0.079 0.157 0.394 0.197 0.197 0.394 Double-feed –0.394 –0.197 0.197 0.394 Detection (Up) Left Center Right (Down) (Up) Left Center Right (Down) Screeing edge position ℓ (mm in) Deviation ℓ (mm in) Deviation ℓ (mm in)

HL-T1 HL-T1010A HL-T1010F LA Correlation between transverse Correlation between interrupted deviation and output voltage beam width and output voltage LD 8 8 Horizontal direction Vertical direction 250 mm 9.843 in Sensing object 500 mm 19.685 in 500 mm 19.685 in Receiver Receiver Emitter ℓ + Receiver ) ) V

Emitter Emitter V ( 6 ℓ ℓ ( 6 – Vertical direction 500 mm 19.685 in 4 Horizontal direction 4

The graph depicts the correlation between transverse deviation 2 and output voltage when the 2 full-scale setting ranges from 0 V Linear output voltage

(light beam is interrupted) to 5 V Linear output voltage (light beam is fully incident), using the Monitor Focus function. 0 0 10 5 0 5 10 –10 –5 0 5 10 0.394 0.197 0.197 0.394 –0.394 –0.197 0.197 0.394 (Up) Left Center Right (Down) Screeing edge position ℓ (mm in) Deviation ℓ (mm in) Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES 1130

Refer to p.1501 for general precautions and p.1499~ for information about laser beam. FIBER PRECAUTIONS FOR PROPER USE SENSORS

LASER Safety standards for laser beam products SENSORS • This catalog is a guide to select a suitable product. Be PHOTO- sure to read instruction manual attached to the product • A laser beam can harm human being’s eyes, skin, etc., ELECTRIC prior to its use. because of its high energy density. IEC has classified SENSORS MICRO laser products according to the degree of hazard and the PHOTO- ELECTRIC stipulated safety requirements. SENSORS The series is classified as Class 1 laser. • Never use this product as a sensing device HL-T1 AREA SENSORS for personnel protection. (Refer to About laser beam.) LIGHT • In case of using sensing devices for CURTAINS / Classification by IEC 60825-1 SAFETY personnel protection, use products which COMPONENTS PRESSURE / meet laws and standards, such as OSHA, FLOW ANSI or IEC etc., for personnel protection Classification Description SENSORS applicable in each region or country. INDUCTIVE that are safe under reasonably foreseeable conditions of operation, PROXIMITY Class 1 SENSORS including the use of optical instruments for intrabeam viewing. PARTICULAR Lasers emitting in the wavelength range from 302.5 nm to 4,000 nm USE • This product is classified as a Class 1 Laser Class 1M which are safe under reasonably foreseeable conditions of operation, SENSORS but may be hazardous if the user employs optics within the beam. Product in IEC / JIS regulations and a Class SENSOR II Laser Product in FDA regulations 21 CFR Lasers that emit visible radiation in the wavelength range OPTIONS from 400 nm to 700 nm where eye protection is normally 1040.10. Do not look at the laser beam SIMPLE afforded by aversion responses, including the blink reflex. WIRE-SAVING Class 2 UNITS through optical system such as a lens. This reaction may be expected to provide adequate protection • The following label is attached to the under reasonably foreseeable conditions of operation WIRE-SAVING product. Handle the product according to the including the use of optical instruments for intrabeam viewing. SYSTEMS instruction given on the warning label. Lasers that emit visible radiation in the wavelength range from 400 nm MEASURE- to 700 nm where eye protection is normally afforded by aversion MENT Class 2M SENSORS The English warning label based on responses, including the blink reflex. However, viewing of the output STATIC may be more hazardous if the user employs optics within the beam. ELECTRICITY FDA regulations is pasted on the PREVENTION DEVICES FDA regulations conforming type. Lasers that emit in the wavelength range from 302.5 nm to 106 nm where direct intrabeam viewing is potentially hazardous but the risk is LASER Class 3R MARKERS lower than for Class 3B lasers, and fewer manufacturing requirements and control measures for the user apply than for Class 3B lasers. PLC Lasers that are normally hazardous when direct intrabeam exposure Class 3B occurs (i.e. within the NOHD). Viewing diffuse reflections is normally safe. HUMAN Lasers that are also capable of producing hazardous diffuse reflections. MACHINE Class 4 INTERFACES They may cause skin injuries and could also constitute a fire hazard. ENERGY CONSUMPTION VISUALIZATION Safe use of laser products COMPONENTS FA • For the purpose of preventing users from suffering injuries by laser products, IEC 60825-1 “Safety of laser products”. Kindly COMPONENTS

check the standards before use. (Refer to p.1499~ for information about laser beam.) MACHINE VISION SYSTEMS

UV CURING SYSTEMS

Selection Guide Laser Displacement Magnetic Displacement Collimated Beam Digital Panel Controller Metal-sheet Double-feed Detection

HL-T1

LA

LD 1131 Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES

FIBER Refer to p.1501 for general precautions and p.1499~ for information about laser beam. SENSORS PRECAUTIONS FOR PROPER USE

LASER SENSORS Functions Functional description ① ⑥ ⑤ ③ ⑫ ⑨ ⑪ PHOTO- ② ELECTRIC SENSORS Function Details MICRO PHOTO- The following tasks can be done by executing zero ELECTRIC SENSORS reset. • The display value can be set at “0”. AREA Zero reset • The linear output when the display reads “0” is SENSORS function made the center output value of the 2 points set LIGHT CURTAINS / by monitor focus. (In the default state, the current SAFETY output is 12 mA and the voltage output is 0 V.) COMPONENTS PRESSURE / FLOW The auto scaling function selects whether to display ④ ⑧ ⑦ ⑩ ⑬ SENSORS the laser beam reception amount in the main-digital INDUCTIVE display in “mm” units or in “%” units, and determines PROXIMITY whether the amount of laser beam received or the Description Function SENSORS Auto scaling amount of laser beam interrupted is displayed. With PARTICULAR function the set standard laser beam reception amount as the USE Laser emitting indicator SENSORS reference value, the current laser beam reception Lights up when the sensor head is emitting laser (LD ON) amount (laser beam interrupted amount) is scaled beam. SENSOR automatically and is displayed as well as being (Green LED) OPTIONS output. Judgment output indicators HIGH: Orange LED (lights up when measured value HIGH threshold value) SIMPLE (HIGH / PASS / LOW) PASS: Green LED (lights up when HIGH threshold value measured value LOW threshold value) WIRE-SAVING This function registers and stores the current laser UNITS (Orange / Green / Yellow LED) LOW: Yellow LED (lights up when LOW threshold value measured value) beam reception amount in memory as the standard Main digital When in the RUN mode, it displays the measured value (mm/%). WIRE-SAVING laser beam reception amount. The laser beam SYSTEMS reception amount during full laser beam entry display During measurement hold, it displays the hold value (mm/%). Standard becomes the 100 % laser beam reception amount’s (5 digit red LED) In Reverse mode, the top and bottom are displayed in reverse. MEASURE- MENT received light full scale (F.S.). If this function is used, the display When in the RUN mode, it displays the threshold value, voltage / Sub-digital SENSORS setting and the linear output are set on the full scale (F.S.) current value, light reception amount or resolution. When in the THR display STATIC automatically. It can also be used to correct the laser mode, it displays the respective threshold values. In reverse mode, ELECTRICITY (5 digit yellow LED) PREVENTION beam reception amount when there is a change in the top and bottom are displayed in reverse. DEVICES the laser beam reception amount due to dirt, etc. on Enable indicator Lights up when operation is normal. Goes off when LASER the front glass. MARKERS (ENABLE) operation is abnormal (if the sensor head is not The scaling function is a function that changes the (Green LED) connected when the power is turned on). display value to the desired amount with respect to PLC Scaling function Zero reset the setting value. At the desired distance, the display indicator (ZERO) Lights up when the zero reset function is enabled. HUMAN value can be input and changed. (Green LED) MACHINE INTERFACES Hysteresis width The following 3 modes can be selected. This function sets the hysteresis to the desired value. ENERGY setting function Mode selection • RUN mode: Measuring mode CONSUMPTION VISUALIZATION switch • THR mode: The threshold values are set in this mode. COMPONENTS With this function, the linear output range and • FUN mode: Each of the settings are set in this mode. inclination, etc. with respect to the display value can FA Monitor focus be specified. Setting is done by determining the 2 Threshold value When in the THR / RUN mode, this switches the COMPONENTS function output values with respect to the desired display select switch set threshold value (HIGH / LOW). MACHINE values. VISION UP key • RUN mode: Timing input SYSTEMS This function makes the amount of change in the • THR mode: Changes the threshold value (forward direction) • FUN mode: Changes the function setting value (forward direction) UV measured value an output value. Use this function CURING Differential when measuring if you are paying attention to SYSTEMS function • RUN mode: Press for 3 sec. or more: Standard light reception changes in measured values, as when counting the DOWN key amount setting input number of workpieces, etc. • THR mode: Changes the threshold value (reverse direction) • FUN mode: Changes the function setting value (reverse direction) The digital display’s direction can be selected. The Display reverse forward direction or the reverse direction to match • RUN mode: Changes the contents of the sub-digital display function the direction of installation on the equipment can be RIGHT key (forward direction) selected. • THR mode: Changes the threshold value digit (forward direction) Selection • FUN mode: Sets function selection (forward direction) Guide ECO display This function makes the display dark and saves • RUN mode: Changes the contents of the sub-digital display Laser function electric power. Displacement LEFT key (reverse direction) • THR mode: Changes the threshold value digit (reverse direction) Magnetic This determines the number of display digits in the Displacement • FUN mode: Sets function selection (reverse direction) Display digits main-digital and sub-digital displays. If the number of Collimated Beam limitation function digits is limited, the digits are turned off beginning • RUN mode: Pressing for 1 sec. or more, executes zero reset. Pressing together with the RIGHT key for 3 sec. or Digital Panel with the lowest order digit. Controller more, cancels zero reset. Metal-sheet This selects whether or not to save the zero reset ENT key • THR mode: When threshold value is blinking, the threshold value Double-feed Detection level in memory when the power is turned OFF. If is set. When the threshold value lights up, teaching you desire to reproduce the zero reset level from the is executed. Zero reset memory • FUN mode: When the set value is blinking, the value is set. previous operating session when you turn the power function When the setting is being initialized, pressing for a long HL-T1 ON again, then enable this function. If this function is time executes initialization. enabled, the zero reset level data are written into the LA EEPROM each time. Others LD The controller’s key input can be disabled. Once the Key lock key input is disabled, the controller will not accept • This product outputs the judgment of the laser light analog function any key inputs until the key lock is released. Use this quantity. Since there is variation in the light intensity between function to avoid changing the setting by mistake. the center and the edges of the detection area, and the emitter side and the receiver side, the “display value” does Connection not equal “the actual dimensions”, so caution is necessary. • This product is made to satisfy the specifications when the Use the displayed dimensional value as a criterion. sensor head is combined with the controller. In any other • If the object being measured has a surface or is combination, not only may it not satisfy the specifications, a transparent body, it may be impossible to measure it but could be the cause of breakdown. So by all means, accurately, so please exercise caution. use it so that there is a combination of the sensor head • Absolutely do not attempt to disassemble this product. and the controller. Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES 1132

The CAD data in the dimensions can be downloaded from our website. FIBER DIMENSIONS (Unit: mm in) SENSORS

LASER HL-T1001A(F) HL-T1005A(F) Sensor head SENSORS PHOTO- ELECTRIC 2-ø3.2 ø0.126 2-ø3.2 ø0.126 SENSORS 2.8 ø2.6 ø0.102 cable, 0.5 m 1.640 ft long (Black) ø2.6 ø0.102 cable, 34 0.2 0.008 MICRO 0.110 Manufactured by PHOTO- 0.5 m 1.640 ft long (Gray) 1.339 16 19 (1.5) (0.059) 0.748 J.S.T. Mfg. Co., Ltd. ELECTRIC 0.630 2.8 XARR-04VF* SENSORS 5 0.197 0.110 AREA 9 15 SENSORS 0.354 0.591 15 9 0.591 0.354 LIGHT Manufactured by CURTAINS / SAFETY J.S.T. Mfg. Co., Ltd. (36.5) (6.9) COMPONENTS XARR-04VF* (1.437) * The sensor heads that were produced before January 2006 use the connector shown below. (0.272) PRESSURE / Certification / identification label (Note 1) Please note that the new connector and previous connector are incompatible. FLOW SENSORS (50 µm 1.969 mil polyester film) (10) INDUCTIVE PROXIMITY (0.394) SENSORS Light beam shielding plate (Note 1) Manufactured by Molex 51029-0410 Emission indicator (Green) PARTICULAR USE Beam axis (Note 2) SENSORS 15 0.591 SENSOR 15 OPTIONS 0.591 SIMPLE Emitter WIRE-SAVING UNITS Receiver Notes: 1) IEC / JIS conforming products do not contain light beam shielding plate, WIRE-SAVING or certification / identification label. SYSTEMS 2) The receiver of HL-T1001A(F) does not incorporate a slit. MEASURE- MENT SENSORS HL-T1010A HL-T1010F Sensor head STATIC ELECTRICITY PREVENTION DEVICES 2-ø3.2 ø0.126 2-ø3.2 ø0.126 LASER 2.8 42 0.2 ø2.6 ø0.102 cable, 0.5 m 1.640 ft long (Black) MARKERS ø2.6 ø0.102 cable, 0.110 1.654 0.008 25 2.8 Manufactured by 0.5 m 1.640 ft long (Gray) 0.984 0.110 J.S.T. Mfg. Co., Ltd. (6.9)(0.272) 10 XARR-04VF* 0.394 PLC 14 20 0.551 0.787 20 14 HUMAN 0.787 0.551 MACHINE INTERFACES Manufactured by 22 ENERGY J.S.T. Mfg. Co., Ltd. (36.5) 0.866 (1.5) * The sensor heads that were produced before January 2006 use the connector shown below. XARR-04VF* CONSUMPTION (1.437) (0.059) Please note that the new connector and previous connector are incompatible. VISUALIZATION COMPONENTS Certification / identification label (Note) (50 μm 1.969 mil polyester film) FA COMPONENTS (10) (0.394) Manufactured by Molex MACHINE 51029-0410 VISION SYSTEMS Emission indicator Light beam shielding plate (Note) (Green) Beam axis UV CURING 20 SYSTEMS 0.787 20 0.787

Emitter Receiver Note: IEC / JIS conforming products do not contain light beam shielding Selection plate, or certification / identification label. Guide Laser Displacement HL-AC1 HL-AC1P Controller HL-AC1-CL Calculation unit (Optional) Magnetic Displacement Collimated Mounting drawing with a mounting bracket MS-HLAC1-1 (Optional) Beam Digital Panel Connector for calculation unit Linking connector Controller connection (on each side) 24.9 Metal-sheet 0.980 Double-feed Detection (3.6) 64.3 32.2 1.268 (0.142) 2.531 30 1.181 Connection indicator (Orange) HL-T1 34.3 4.3 0.169 1.350 15.8 15.1 LA 13.2 0.594 0.520 0.622 12 0.472 57 2.244 LD 8 0.315 54.9 2.161 3.9 22.4 16 ø5.2 ø0.205 cable, 0.154 0.882 0.630 2 m 6.562 ft long 13 36.8 30 0.512 Suitable for 35 mm 1.378 in 26 1.449 1.181 1.024 2-ø3.2 ø0.126 width DIN rail 5.4 5 36.7 150 5.906 approx. 0.213 3.4 1.445 3.4 0.197 ø5.1 ø0.201 cable 3.4 0.134 0.134 0.134 Suitable for 35 mm 1.378 in width DIN rail 32.2 1.268 16.1 0.634 Connector for 5.4 0.213 sensor head connection 22.4 16 0.882 0.630 1133 Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES

FIBER The CAD data in the dimensions can be downloaded from our website. SENSORS DIMENSIONS (Unit: mm in)

LASER SENSORS MS-HLT1-1 Sensor head mounting bracket for HL-T1001A(F) / HL-T1005A(F) [Accessory for HL-T1001A(F) / HL-T1005A(F)] PHOTO- ELECTRIC Assembly dimensions 3.4 15 SENSORS 1 0.134 2 0.591 6 MICRO 1.1 9 7 5 Mounting drawing with HL-T1005A’s receiver PHOTO- ø3.2 ø0.126 0.043 0.354 0.276 0.197 9 0.236 ELECTRIC 0.354 SENSORS

AREA 3.2 0.126 SENSORS 9 0.354 3.4 2-M3 × 0.5 0.020 LIGHT 0.134 5 CURTAINS / 14.5 12.5 3.2 0.197 (34.6) 0.492 SAFETY (1.362) 0.571 0.126 1.6 0.063 COMPONENTS 5 0.197 PRESSURE / 5 0.197 9 FLOW t 1.6 10 0.354 SENSORS 13.1 t 0.063 0.394 3.4 0.134 0.516 3 0.118 INDUCTIVE 1.1 9 PROXIMITY 0.043 3.4 0.134 SENSORS 0.354 2-ø3.2 ø0.126 5 1.6 0.063 1.1 0.043 9 0.354 PARTICULAR 0.197 5 USE 0.197 5 0.197 SENSORS 3.4 0.134 SENSOR 17 9 t 1.2 3.2 0.354 OPTIONS 0.669 t 0.047 17 0.126 7 0.669 0.276 9.5 SIMPLE 0.374 WIRE-SAVING 5 UNITS 17 ø3.2 ø0.126 0.197 5 17 13.1 0.669 0.197 0.669 t 1.2 0.516 3.4 24.5 t 0.047 WIRE-SAVING 0.134 SYSTEMS 0.965 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) MEASURE- MENT Two M3 (length 20 mm 0.787 in) screws with washers are attached. SENSORS STATIC ELECTRICITY PREVENTION DEVICES MS-LA3-1 Sensor head mounting bracket for HL-T1010A(F) [Accessory for HL-T1010A(F)] LASER MARKERS Assembly dimensions 1 2

PLC 20 20 Mounting drawing with HL-T1010A’s receiver 0.787 2-ø3.2 ø0.126 6 0.787 14 0.236 14 2-ø3.2 ø0.126 HUMAN 0.551 0.551 MACHINE INTERFACES 2.6 13 6 0.236 0.102 ENERGY 0.512 CONSUMPTION 3.4 2-M3 × 0.5 0.020 VISUALIZATION 14 0.134 COMPONENTS 0.551 16 (45.1) 23 0.630 (1.776) FA 0.906 2.6 COMPONENTS 3.4 0.134 t 1.6 0.102 2.6 0.102 t 0.063 14 MACHINE 3 14 0.551 VISION 0.118 0.551 10 SYSTEMS 2.6 0.102 0.394 3 0.118 2-ø3.2 ø0.126 UV 3.4 0.134 3.4 CURING 0.134 3.4 0.134 SYSTEMS 2.6 0.102 3 14 0.118 0.551 23 14 3.4 0.551 10 0.906 13 0.134 0.394 0.512 2.6 6 0.236 0.102 23 10 t 1.6 23 0.906 0.394 0.906 t 0.063 13 Selection Guide Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) 0.512 Laser Two M3 (length 25 mm 0.984 in) screws with washers are attached. 23 Displacement 0.906 20 t 1.6 0.787 Magnetic 33 t 0.063 Displacement 1.229 Collimated Beam Digital Panel Controller MS-HLAC1-1 Controller mounting bracket (Optional) CN-HLT1-1 Sensor head to controller connection cable (Accessory for sensor head) Metal-sheet Double-feed Detection 34.8 +200 1,500 0 1.370 2-ø3.2 ø0.126 +7.874 22 46 59.055 0 Gray

HL-T1 2.5 0.866 3 1.811 0.098 16 0.118 ø15 LA 0.630 ø0.591 7.3 Manufactured by Hirose Black LD 0.287 Electric Co.,Ltd. RP17-13P-12PC 3 3 ø2.6 ø0.102 × 2 0.118 26.8 0.118 Manufactured by J.S.T. Mfg. Co., Ltd. XAP-04V-1* 1.055 16 * The sensor heads that were produced 3.4 0.630 5.4 5.3 before January 2006 use the connector 0.134 0.213 0.209 shown below. 5.4 Please note that the new connector and 0.213 previous connector are incompatible. 32.2 27.2 27.2 1.268 1.071 1.071 3.4 0.134 t 1.0 Manufactured by t 0.039 Molex 51030-0430 Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES 1134

The CAD data in the dimensions can be downloaded from our website. FIBER DIMENSIONS (Unit: mm in) SENSORS

LASER HL-T1SV1 Side-view attachment for HL-T1001A(F) / HL-T1005A(F) (Optional) SENSORS PHOTO- Assembly dimensions ELECTRIC SENSORS Mounting drawing with HL-T1005A’s receiver MICRO PHOTO- 2.7 ELECTRIC 0.106 SENSORS AREA 15 15 SENSORS 0.591 0.591 LIGHT CURTAINS / SAFETY (34) COMPONENTS Beam axis (1.339) 2-ø2.2 ø0.087 Beam axis 15 19 PRESSURE / FLOW 0.591 0.748 SENSORS

INDUCTIVE 15 10.6 15 PROXIMITY 0.591 0.417 0.591 SENSORS PARTICULAR 7.5 12.5 USE 2.2 SENSORS 0.087 0.295 0.492 15 0.591 SENSOR OPTIONS Material: Polyetherimide (Enclosure), Glass (Front cover) SIMPLE Two M2 (length 6 mm 0.236 in) screws with washers are attached. WIRE-SAVING UNITS

WIRE-SAVING SYSTEMS HL-T1SV2 Side-view attachment for HL-T1010A(F) (Optional) MEASURE- MENT Assembly dimensions SENSORS STATIC Mounting drawing with HL-T1010A’s receiver ELECTRICITY PREVENTION DEVICES

LASER MARKERS 2.8 20 0.110 0.787 PLC

20 (46) HUMAN MACHINE 0.787 (1.811) INTERFACES 21 25 ENERGY CONSUMPTION 0.827 0.984 VISUALIZATION COMPONENTS 2-ø2.2 ø0.087 Beam axis Beam axis FA COMPONENTS 20 20 15.6 0.787 MACHINE 0.787 0.614 VISION SYSTEMS

11 UV 2.2 0.433 CURING 0.087 21 21 SYSTEMS 0.827 0.827

Material: Polyetherimide (Enclosure), Glass (Front cover) Two M2 (length 6 mm 0.236 in) screws with washers are attached.

Selection Guide Laser Displacement Magnetic Displacement Collimated Beam Digital Panel Controller Metal-sheet Double-feed Detection

HL-T1

LA

LD