Garage, Carport & Shed Builder

Total Page:16

File Type:pdf, Size:1020Kb

Garage, Carport & Shed Builder NEW SHOW COMING IN 2021! A Constructiontion MMagazineagaz Network Brand Spring 2020 www.constructionmagnet.comtitioonnmmaaggnneett.c.comom EXTERIOR COSMETIC & PREMIER FINISHING ISSUE OPTIONS ARE ALL GARAGE DOORS THE SAME? PRODUCT PROFILES: SHEDS CUPOLAS & VENTILATION AS CABINS GGCSB_CVRspring2020.inddCSB_CVRspring2020.indd 1 11/14/20/14/20 111:241:24 AAMM Fight Condensation Without Insulation Stop the Dripping from Condensation Tired of Customers complaining about a dripping roof? Let DripStop solve your condensation problems before they start. DripStop is applied at the time of roll forming • Unmatched Durability Adhesive • Prevents Bird Nesting Issues • Easy to Clean • Maintenance Free • Weather Resistant When condensation occurs, moisture gets stored in the specially designed pockets of the DripStop membrane. Quicker – Easier – Cheaper Than other anti-condensation solutions Circle Reader Service #066 Ask for it from your preferred roof panel supplier www.dripstop.com or call us at: 1-(937) 660-6646 FFULLULL PPAGEAGE AADS.inddDS.indd 2 11/14/20/14/20 110:100:10 AAMM Circle Reader Service #038 FFULLULL PPAGEAGE AADS.inddDS.indd 3 11/14/20/14/20 110:100:10 AAMM 12 CONTENTS Features: 12 Function First Are All Garage Doors The Same? 20 Framing Options 42 Wood Works & Steel Stands 26 Dress It Up 42 Show Highlights Exterior Cosmetic & Finishing Options First Construction Rollforming Show A Success 32 Fit For Living Cabin Options To Think About 46 Product Feature Cupolas & Weathervanes 40 What Do You Need? Construction Rollforming 48 Make Business Better Association Survey With Better Time Management 4 GARAGE ■ CARPORT ■ SHED BUILDER / SPRING 2020 44-5-TOC.indd-5-TOC.indd 4 11/14/20/14/20 22:20:20 PPMM Managing Editor Karen Knapstein [email protected] 715-598-4004 Editor Jessica Franchuk [email protected] 920-224-5146 Publisher Gary Reichert [email protected] 715-252-6360 Designers Tom Nelsen Kevin Ulrich Executive Assistant Kathy Budsberg [email protected] Circulation/Database Manager Missy Fenn [email protected] 715-446-4243 Subscription Questions [email protected] 715-446-4243 Customer Service [email protected] Garage, Carport & Shed Builder is published quarterly, Spring, Summer, Fall and Winter, by Shield Wall Media LLC, PO BOX 255, Iola WI 54945. Copyright 2020 Shield Wall Media LLC. Names and logos referred to or displayed in editorial or advertising content may be trademarked or copyright. Garage, Carport & Shed Builder assumes no responsibility for unsolicited materials sent to it. On The Cover: Western red cedar wood garage door from Publisher and advertisers are not liable for typographical errors that may appear in prices or descriptions in advertisements. Mailed free to Safe-Way Doors’ “Ridge” series. Above: “Monarch” doors. COURTESY OF SAFE-WAY DOORS rural contractors and their suppliers throughout North America. See Us At International Roofi ng Expo Booth #329 See Us At Frame Building Expo Departments: Booth #342 6 Editor’s Note 8 Show Announcement 10 Industry News 17 Subscribe To GCSB 38 Advertiser Index 38 Events Calendar 45 Product Profi les: 26 45 Cupolas & Ventilation • Slabs, Floors, & Finishing Options Next • In-Floor Radiant Heat • What Makes A She-Shed Issue: • Designing To Match Or Complement Existing Structures www.constructionmagnet.com 5 44-5-TOC.indd-5-TOC.indd 5 11/14/20/14/20 22:20:20 PPMM EDITOR’S NOTE What Do You Think? eing relatively new to I hope I’ve succeeded and that you tion and we’ll see if we can’t gather up construction media, do fi nd value in it and are inspired by enough submissions to have a regularly speaking with industry it. Feel free to drop me a line and let me scheduled “Shed Showcase” in each issue. professionals — manu- know what you think. I’m counting on My door is always open. Drop me a facturers, builders, suppli- you all to let me know what you would line at [email protected] or Bers — is invaluable to me. I feel like I’ve like to see added to this magazine. (Sub- snail mail Karen Knapstein, GCSB learned a lot over the last six months, scribe by fi lling out and sending in the Editor, C/O Shield Wall Media, PO Box but I know it’s just a drop in the bucket form on page 17.) 255, Iola WI 54945. compared to what you, as professionals, Speaking of inspiration, I’d like to take know. this opportunity to ask all of the build- Over the last several weeks I’ve been ers out there: Have you built a garage, hounding — yes, hounding — people in carport, or some sort of shed that you the know in an effort to create a maga- are especially proud of? Have you built a PS: If you’re at International Roofi ng zine that you fi nd value in. The result is shed that you would like to show off? Expo in Dallas, fi nd us at Booth #329, this very fi rst edition of Garage, Carport If you have, please send me a high and at Frame Building Expo, we’ll be & Shed Builder Magazine! resolution photo and a brief descrip- camping out in Booth #342. 411 Circle Reader Service #069 6 GARAGE ■ CARPORT ■ SHED BUILDER / SPRING 2020 66-ED-ED NNOTE.inddOTE.indd 6 11/14/20/14/20 11:55:55 PPMM 40-Year Superior Quality Superior Value Class A Fire Rated Proven performance–preferred by contractors for over 30 years. THE ORIGINAL CUSTOM RIDGE VENT !ɖɎɎȒˡɎStanding Seam and Screw-Down Panels in over ,׎¨ȸȒˡǼƺɀ for Commercial, Agriculturalד and Residential MMetaletal RRoofs.oofs. ɵƺƏȸǼǣȅǣɎƺƳɯƏȸȸƏȇɎɵٮ׎גى JǼɖƺɀȵȒɎɀȵȸƺɮƺȇɎɀǼǣȵȵǣȇǕƳɖȸǣȇǕǣȇɀɎƏǼǼƏɎǣȒȇɎǣȒȇى IǣɎɀɖȇƳƺȸƏȇɵȸǣƳǕƺƬƏȵى Á È«z AlsoAAlso AvailableAvailable inin ǼƏɀɀIǣȸƺ«ƏɎǣȇǕ٫áXnnz!ى ȒɖɎǣȇɀɎƏǼǼƏɎǣȒȇ 3' HHii Rib Stick ¾" andٮȇƺȵƺȸɀȒȇȸȒǼǼ ى R PaPanelnel SticksStici ks ɮƺȸȒȇƺȅǣǼǼǣȒȇǣȇɀɎƏǼǼƺƳ٫ɿƺȸȒƬƏǼǼƫƏƬǸɀ ى 2" or 3" wide. ח׏ِ׎אז׎ٮו׏يƏƳƺƏȵȵȸȒɮƺƳzȒƏzȒِ)ٮxǣƏȅǣى Please check out our new website: www.profilevent.com ƬɖɀɎȒȅƺȸɀƺȸɮǣƬƺ۬ɮƺȇɎƬȒǣȇƬِƬȒȅىד׏דחٮ׎׎בٮבבזÁȒǼǼIȸƺƺ ©2020 ProfileVent®s-ANUFACTUREDINTHE53!BY6ENTCO)NC Circle Reader Service #320 FFULLULL PPAGEAGE AADS.inddDS.indd 7 11/14/20/14/20 99:20:20 AAMM TRADE SHOW NEWS Garage, Carport & Shed Builder Show New Construction Trade Show Slated For 2021 hen we announced the launch of Garage, but we are smiling ear to ear and growing. The reason we can Carport, & Shed Builder magazine, the re- grow when others struggle is we know our business and realize sponse was overwhelmingly positive. There that you know yours. was an immediate buzz and the excitement “The show details, date, and location should be fi nalized by was palpable. It was April,” Reichert continued. Wclear that this is an underserved segment of Consider this an open invitation: Tell us what the construction trade. you want in the magazine or at the show. What To meet the needs of this segment, in 2021, information can we provide that is valuable to Shield Wall Media will launch a new trade you? Working together, we succeed together. show — The Garage, Carport & Shed Builder “We are growing because of your Show — at which builders and contractors can fi nd informa- knowledge,” said Reichert. “Let’s work together to grow tion, resources, and insights to grow success and increase profi ts. the industry and make the Garage, Carport & Shed The venue and dates are not yet fi nalized, said Shield Wall Builder Show a huge success!” GCSB Media publisher Gary Reichert. “But one thing is certain: The reason the Construction Rollforming Show and Rollforming Send suggestions to Gary Reichert Magazine launched successfully is because we listened to you. ([email protected]) or Karen “Some shows are shrinking, some publications are struggling, Knapstein ([email protected]). COURTESY OF MORTON BUILDINGS 8 GARAGE ■ CARPORT ■ SHED BUILDER / SPRING 2020 88-GCS-GCS SSHOW.inddHOW.indd 8 11/14/20/14/20 110:080:08 AAMM Statistic from Business Insider ABOUT 80%... of New Year’s resolutions fail by the second week of February. Turn a new leaf. Flip to the next page. Do what you have to do to keep your 2020 resolution... We’ll be waiting for you. 625 Talk to us at the 2020 Frame Building Expo. Let’s make that resolution a reality. Circle Reader Service #178 FFULLULL PPAGEAGE AADS.inddDS.indd 9 11/14/20/14/20 99:02:02 AAMM INDUSTRY NEWS Vice Chair, Construction AAMA, IGMA Unify, Form Industry Alliance For New Trade Organization fen·es·tra·tion Suicide Prevention Appointed The American Architectural Manu- noun ARCHITECTURE Associated Builders and Contrac- facturers Association (AAMA) and the the arrangement of windows and doors tors has announced Greg Sizemore, the Insulating Glass Manufacturers Alliance on the elevations of a building. association’s vice president of health, (IGMA) have offi cially combined into one safety, environment, and workforce organization with the new name: Fen- development, has been appointed vice estration and Glazing Industry Alliance ing the glass, glazing, and fenestration chair of the Construction Industry (FGIA). After a July 2019 vote by both industry through research, consensus- Alliance for Suicide Prevention. In this bodies to unify, the two organizations based standards, product certifi cation, role, Sizemore will help support the have come together as of Jan. 1, 2020. advocacy, and education and professional alliance’s mission to address suicide The AAMA and IGMA boards of development. prevention as a construction health directors met in early December to fi nal- FGIA 2020 events include, but are not and safety priority and achieve a zero- ize the vision and mission of the unifi ed limited to: the FGIA Annual Conference, suicide industry. organization. Feb. 10-13, Marriott Harbor Beach, Ft. Men in the construction and extraction The vision focuses on improving home Lauderdale, Florida; the Southeast Region industry had the highest rate of suicide and building performance through better Winter Meeting Feb.
Recommended publications
  • Manufactured Home and Carport, Deck, Shed, and Stairs
    MANUFACTURED HOME, CARPORT, DECK, SHED, & STAIR IN A PARK City of Newberg City Hall ~ P.O. Box 970 ~ 414 E First Street ~ Newberg, OR 97132 ~ Phone: (503) 537-1240 ~ Fax: (503) 537-1272 www.newbergoregon.gov \\ncd-admin\data\WP\COMMON\FormsCD\Bldg Div Forms\Manufactured Home Carport Deck Shed Stair Packet 2012.doc 1-27-21 Page 1 Submitting a Permit SUBMITTAL Permit Application Applications are available online at www.newbergoregon.gov and City Hall. Submit an application for the manufactured home and a separate application for carport, deck, shed and stair. Two Construction Plans Drawn to scale with dimensions. Submit plans for carport, deck, shed, and stair. Plan not required for manufactured home in a park. Plan are required for placement on an individual lot, see page 5 for additional planning requirements. Two Site Plans A bird’s eye view of the lot showing existing and proposed structures, distance to property lines and other buildings, and elevations. See page 3 and 4 for a sample plan and page 5 for requirements. Circle the Space Number on the Park Map and Submit See pages 7-15 for park maps. Setbacks See page 6 for setback requirements. Fees The plan review fee is due at submittal and the remaining fees are due at the time of issuance for the carport, deck, shed and stair application. A fee is not required at submittal for a manufactured home application, instead fees are due at time of issuance. Sample fee brochure online at www.newbergoregon.gov. INSPECTIONS Call (503) 554-7714 for Inspections If the permit holder or the permit holders agent fails to call for a setup inspection or causes the under floor area to be enclosed prior to the setup inspection, the permit holder or the permit holder agent shall remove the skirting prior to obtaining an inspection or hire a certified inspector to perform the set up inspection.
    [Show full text]
  • Solar Carport Portable Light
    Solar Carport Portable Light Solar Carport / Portable light have many application from Gazebo, bus stop, detached carport, outdoor kiosks, comping tents, boats and any remote locations where grid is a challenge. Our Solar Carport / portable light comes with standard and flexible solar panel for curved surface installations. • Our carport / Portable light comes with standard and flexible solar panel for curved surface installations. Our carport light also has the ability for solar scalability enables adding panels for demanding weather conditions. • Using High power LED light source with advanced design to make our carport a super bright luminous efficacy fixture of 130 lumens per watt. • The variable lighting mode function is designed with the advanced microwave motion sensor. • Built in battery, charge and discharge over 1000 times. • The light automatically switches off on at dusk and switches off at dawn. 50% permanent lighting, when motion is detected power turns to 100% • 2 Years warranty on all components. • MC4 plug in connection. • 130 Lumens per watt and IP68 rated SOLAR PORTABLE LIGHTS SOLAR PORTABLE 12W 23.6” / 18W 23.6” / 24W 35.4” / 36W 35.4” / 48W 47.2” 3.6” 3.3” 1 1939 Parker Ct Stone Mountain, GA, 30087 | Toll Free: (800) 316-4716 | www.beyondsolar.net Solar Carport Portable Light Specifications Lithium Beam Model # SKU # Power PV Type Solar Panel Lumens CCT Controller IP Rating Battery Angle AVS-SCL12W 786400 12W MONO 40W 12AH 1500LM 5000K PWM 240° IP67 AVS-SCL18W 786401 18W MONO 50W 16AH 2200LM 5000K PWM 240° IP67 AVS-SCL24W
    [Show full text]
  • RES Det. Garage & Carport
    Door Requirements To distinguish between a detached ga- rage and a storage structure, the width Community and Development of the door is considered. If the door is Residential eight feet or wider, then the structure is Services Department considered a detached garage. If the Detached door is narrower than eight feet in Garage & width, the structure is considered a stor- Building Services Division age building. Parking of motor vehicles is C a r p o r t not permitted in a storage building. 785-309-5715 Planning Division 785-309-5720 GARAGE-Driveway Required www.salina-ks.gov STORAGE SHED-Driveway Not Required Community & Development Services City County Building 300 W. Ash, Room 205 785-309-5715 785-309-5720 BLF-307 12/2017 CARPORT Not an Approved Carport I want to build a detached garage or driveway (concrete, asphalt, gravel or asphalt mil- Applying for a permit: carport. What do I need to know? lings) connection to the existing driveway serving Complete and submit a building permit the property or to an existing alley. In order to lo- Detached garages and carports require a application and include the following cate a garage in a rear yard, the owner must dem- building permit. Please visit Develop- documents / information with your sub- onstrate that there is sufficient side yard width ment Services offices or the City of Sa- mittal: lina website to obtain forms and submit- (minimum 8 ft.) to drive a vehicle around the side 1. Site plan - drawn to scale showing tal checklists for construc- of their dwelling to reach the garage.
    [Show full text]
  • Improvement Codes Building Attributes
    IMPROVEMENT CODES CODE TYPE IMPROVEMENT CODE TYPE IMPROVEMENT CODE TYPE IMPROVEMENT BD1 Light Boat Dock FP Fire Place MAA Main Area Addition or Mobile Home BD2 Medium Boat Dock FP1 Fire Place Class 1 MBH Masonry Boat House BD3 Heavy Boat Dock FP2 Fire Place Class 2 MUB Masonry Utility Building BW Breezeway FUB Metal or Frame Utility Building OB Out Building CA Central Air GA Attached Garage OP Open Porch CH Central Heat GH Greenhouse SP Screen Porch CP1 Carport 1, Wood/Concrete HE Heatalator SPA Spa CP2 Carport 2, Wood/Dirt HO Hoist SPOOL Small Pool CP3 Carport 3, Metal/Dirt HT Hot Tub / Jacuzzi ST Storage (Attached to House) CP4 Carport 4, Under Beach House LPOOL Large Pool STG Storage (Detached from House) CPY Canopy MA Main Area 1 Story SV Salvage DG Detached Garage MA1 Main Area 1.5 Story WD Wood Deck EP Enclosed Porch MA2 Main Area 2 Story XPOOL Extra Large Pool FBH Metal or Frame Boat House MA2.5 Main Area 2.5 Story ELV Dumbwaiter or Elevator MA3 Main Area 3 Story BUILDING ATTRIBUTES CONSTRUCTION STYLE EXTERIOR FINISH FOUNDATION SF-M Single Family Modern BV Brick Veneer CS Concrete Slab SF-C Single Family Conventional WF Wood Frame PB Pier & Beam SF-S Single Family Spanish COMP Composition WPR Wood Piers MF-C Multi Family Conventional ST Stucco WOK Wood Pilings R-CT Recreation - Comp Type CB Concrete Blocks PT Post Tension Concrete L-CM Light Commercial AS Asbestos BW Brick & Wood INTERIOR FINISH SV Stone SR Sheetrock ROOF STYLE SI Sheet Iron PA Panel HP Hip SS Structural Steel WP Wallpaper GA Gable WS Wood Shingle FLOORING CS Composition
    [Show full text]
  • Architectural Styles/Types
    Architectural Findings Summary of Architectural Trends 1940‐70 National architectural trends are evident within the survey area. The breakdown of mid‐20th‐ century styles and building types in the Architectural Findings section gives more detail about the Dayton metropolitan area’s built environment and its place within national architectural developments. In American Architecture: An Illustrated Encyclopedia, Cyril Harris defines Modern architecture as “A loosely applied term, used since the late 19th century, for buildings, in any of number of styles, in which emphasis in design is placed on functionalism, rationalism, and up‐to‐date methods of construction; in contrast with architectural styles based on historical precedents and traditional ways of building. Often includes Art Deco, Art Moderne, Bauhaus, Contemporary style, International Style, Organic architecture, and Streamline Moderne.” (Harris 217) The debate over traditional styles versus those without historic precedent had been occurring within the architectural community since the late 19th century when Louis Sullivan declared that form should follow function and Frank Lloyd Wright argued for a purely American expression of design that eschewed European influence. In 1940, as America was about to enter the middle decades of the 20th century, architects battled over the merits of traditional versus modern design. Both the traditional Period Revival, or conservative styles, and the early 20th‐century Modern styles lingered into the 1940s. Period revival styles, popular for decades, could still be found on commercial, governmental, institutional, and residential buildings. Among these styles were the Colonial Revival and its multiple variations, the Tudor Revival, and the Neo‐Classical Revival. As the century progressed, the Colonial Revival in particular would remain popular, used as ornament for Cape Cod and Ranch houses, apartment buildings, and commercial buildings.
    [Show full text]
  • Eichler Design Guidelines City of Sunnyvale
    Eichler Design Guidelines City of Sunnyvale Adopted July 28, 2009 This page has been intentionally left blank. City of Sunnyvale Eichler Design Guidelines TABLE OF CONTENTS 1. INTRODUCTION Why Different Guidelines for Eichlers?............................................... E 5 Intent ............................................................................................. E 5 Applicability ...................................................................................... E 6 When is Design Review Required? .................................................... E 6 2. EICHLER HOMES Special Challenges ..............................................................................E 7 Eichler Home Characteristics ..............................................................E 8 3. DESIGN GUIDELINES 3.1 General Guidelines ................................................................ E 11 3.2 Planning for a Ground Floor Addition .................................... E 13 3.3 Planning for a Second Floor Addition ..................................... E 15 3.4 Planning for an Atrium Cover ................................................. E 17 3.5 Planning for Exterior Improvements ....................................... E 18 3.6 Planning for HVAC Improvements ......................................... E 20 3.7 Planning for a New House ..................................................... E 21 APPENDICES A Eichler Neighborhood Maps ...................................................E 23 B Heritage Resource Districts .....................................................E
    [Show full text]
  • Do I Need a Structural Permit?
    How do I get an inspection? State of Oregon offices Building Codes Division (toll-free) ............ 800-442-7457 Follow these steps: or .......................................................... 503-378-4133 Residential Code Specialist ...................... 503-373-7529 y Call the request line at the building Construction Contractors Board ............... 503-378-4621 Do I need a Better Business Bureau ............................ 503-226-3981 department responsible for your area with at least 24 hours’ notice. Attorney General’s Consumer Hotline: y Portland .................................................... 503-229-5576 When you call to make the Salem ....................................................... 503-378-4320 appointment, have all the details Toll-free .................................................... 877-877-9392 structural (permit number, project address, etc.) available. y If the work was done inside, an adult needs to be at the site for permit? the inspection. Things to do Be an informed consumer. When buying a product or contracting a service, follow these steps: y Call the Building Codes Division or the Construction Contractors Board to $ verify active license and registration. y Call the Better Business Bureau. PermitsProtect.info Safe Homes. Secure Investments. Smart Communities. y Compare prices. y Ask for references and contact them. y Be sure you have a written contract and read it carefully before signing. y Visit PermitsProtect.info for Building Codes Division more tips. 1535 Edgewater St. NW P.O. Box 14470 Salem, OR 97309-0404 440-2672 (1/17/COM) PermitsProtect.info Common questions and key information regarding structural permits When do I need a structural permit? What can I do without a permit? Where do I get a permit? A permit is required to construct, enlarge, A permit is not required for minor repairs Permits are issued by your local building alter, move, or replace any home or related and maintenance.
    [Show full text]
  • Roof Overhang and Building Coverage
    M E M O R A N D U M To: Development Services staff From: Matthew Seubert for Tina Axelrad, Zoning Administrator Date: May 24, 2018 (Revised: 5/14/2020) Re: Denver Zoning Code Clarification — Roof Overhang and Building Coverage Summary This memo provides a written clarification that addresses the following related questions: • At what point is an eave or roof overhang so large that it is considered the roof of a partially enclosed structure? • When does a roof overhang count towards building coverage? In general, and as explained below, a Roof Overhang or Eave that is 3’ or less does not count towards building coverage. A Roof Overhang of 3’ or less may be permitted to encroach into required Setbacks, depending on the zone district and the allowed setback encroachments. A Roof Overhang in excess of 3’ is considered a roof of a Partially Enclosed Structure and counts towards allowed building coverage of the Zone Lot. Discussion – Code Analysis Relevant DZC sections include Sections 4.3.7.4.B.1 and similar provisions in the DZC, Articles 3-9, which specify requirements for setback encroachments. For example, Gutters and Roof Overhangs are permitted to encroach up to 3’ into the Primary and Side Street Setback area in all E Zone Districts, because they are considered minor architectural elements that do not negate the intent of setbacks remaining open to the sky. The Rule of Measurement (ROM) (DZC 13.1.5.13) for Building Coverage, Gross Area of Footprint, states: For purposes of building coverage, ‘gross area of footprint’ shall include: 1.
    [Show full text]
  • KBKG Repair Vs. Capitalization: Improvement Decision Tree
    KBKG Repair vs. Capitalization: Improvement Decision Tree - Final Regulations Considering the appropriate Unit of Property (UOP), does the expenditure (Last Updated 03-20-2015): KBKG expressly disclaims any liability in connection with use of this document or its contents by any third party. Any US tax advice contained herein was not intended or written to be used, and cannot be used, for the purpose of avoiding penalties that may be imposed under the Internal Revenue Code (IRC) or applicable state or local tax law provisions. This document is for educational purposes only and is not intended, and should not be relied upon, as accounting or tax advice. NATIONWIDE SERVICE | 877.525.4462 | KBKG.COM COPYRIGHT © 2018 KBKG ALL RIGHTS RESERVED. ALLSRV. 8/20/2018 KBKG Building Unit of Property & Major Components Chart updated 05-16-17 This chart was created to help users identify building systems & typical “major components” in real estate assets. Replacing a major component is a capital expenditure while replacing an incidental component can be expensed Fire Protection Gas Distribution Building Structure Land Improvements HVAC System Electrical System Plumbing Systems System Security System System Escalators Elevators • Roof System • Landscaping • Heating System • Service & • Plumbing • Sprinkler System • Building security • Gas piping • Stair and • Elevator Car (membrane, including shrubs, (boilers, furnace, Distribution Fixtures (sinks, (piping, heads, alarms including to/ Handrail • Drive System insulation trees, ground radiators) (panel
    [Show full text]
  • CARPORT INTEGRITY POLICY Arizona State Historic Preservation Office
    CARPORT INTEGRITY POLICY Arizona State Historic Preservation Office Prepared by Jason Fox and R. Brooks Jeffery Preservation Studies University of Arizona Adopted October 2005 Purpose In 2004, the staff of the Arizona State Historic Preservation Office (SHPO) and the members of the Arizona Historic Sites Review Committee (HSRC) reviewed the proposed Winterhaven Historic District (Tucson) National Register nomination in which the discussion of integrity was often focused on how the carport, an integral component of ranch style house type, has been modified over the 50+ years of the subdivision. SHPO staff and the HSRC disagreed with the preparers’ evaluation of carport integrity as applied to the proposed Winterhaven Historic District. The preparers were graduate students from a University of Arizona Preservation Studies class under the direction of R. Brooks Jeffery. The preparers took a purist stance that defined criteria for carport integrity as having no modifications to its original form and function. The SHPO staff and the HSRC then recommended that a more thorough study of carports be conducted by the preparers with the purpose of providing a spectrum of options for carport integrity, evaluation criteria, and recommendations to SHPO staff and the HSRC as a policy to guide evaluation of future nominations where the integrity of carports in ranch style house types is at issue. Jason Fox, one of the graduate students in the Preservation Studies program who worked on the original nomination, and Jeffery then completed a draft Carport Integrity Policy for review by SHPO staff and HSRC. The policy presented three scenarios and recommended the third that stated, “All residences with compatible carport garage conversions and compatible enclosures into habitable space are considered contributors.” This policy recommendation was approved for adoption by a unanimous vote by the HSRC in October 2005.
    [Show full text]
  • Article Eight
    ARTICLE NINE Unified Development Code Rev. October 7, 2008 Article Nine – Zoning/Development Standards Table of Contents Page Section 9.01 - Building Design Standards 9-2 Section 9.02 - Off-Street Parking and Loading Requirements 9-8 Section 9.03 - Landscape Requirements 9-16 Section 9.04 - Sign Regulations 9-20 Section 9.05 - Accessory Building and Use Regulations 9-31 Section 9.06 - Fencing Requirements in Residential Zoning Districts 9-33 Section 9.07 - Fencing Requirements in Multi-Family and Non-Residential Districts 9-35 Section 9.08 - Screening Wall Requirements for Multi-Family and Non-Residential Uses 9-36 Section 9.09 - Supplemental Regulations 9-37 • Front Yards 9-37 • Side Yards 9-38 • Special Height Regulations 9-38 • Seasonal/Temporary Uses 9-38 • Fruit/Vegetables Stands 9-39 • Asphalt or Concrete Batching Plants (Temporary) 9-39 • Carnival or Circus (Temporary) 9-40 • Garage Sale 9-41 • Radio, Television, Telecommunication, and Microwave Towers 9-41 • Handicap Accessibility 9-41 • Minimum Dwelling Unit Area 9-41 • Performance Standards 9-42 Section 9.10 - Lighting and Glare Standards 9-43 Section 8.15 - Definitions Section 9.11 - Illustrations 9-66 DRAFT Article Nine – Table of Contents 9-1 ARTICLE NINE Unified Development Code Rev. October 7, 2008 Section 9.01 – Building Design Development Standards A. Exterior Construction Requirements 1. Residential Construction Standards a. SF-LD through 2F: All residential buildings and structures located in the residential districts SF-LD, SF-30 through SF-8.4, and 2F shall be of exterior fire resistant construction having at least eighty percent (80%) of the total exterior walls above grade level and below the first floor plate line, excluding doors and windows, constructed of brick, stone, stucco, or material of equal characteristics as approved by the City in accordance with the City’s building code and fire prevention code.
    [Show full text]
  • When Residential Permits Are Required by State Law, You Will Need a Permit, Inspection and Certification of Occupancy For
    When Residential Permits Are Required By State Law, you will need a permit, inspection and certification of occupancy for: • Change of use or occupancy • Construction of a new building • Any additions or alterations to an existing structure • Structural alterations to an existing dwelling unit • Any garage, carport, shed or greenhouse attached to a house • Any garage, carport, shed or greenhouse not attached to a single family dwelling and is 1000 square feet or larger • Any garage, carport, shed or greenhouse not attached to a two or more family dwelling or to a townhouse • Enclosing a porch or patio • Installing/building a sunroom or “three seasons” room • Installing any deck that is more than 30 inches above ground at any point • Installing any deck that is less than 30 inches above ground if it has a roof or ceiling • Installing any indoor or outdoor hot tub, spa or in-ground swimming pool • Installing any swimming pool (including inflatables) with a depth of 24 inches or more • Installing any fence higher than 6 feet • Installing any retaining wall higher than 4 feet • Changes to an existing means of egress (exit doors, stairs, handrails, guard system, ramps and windows) • Installation of all aluminum or vinyl siding • New installation or replacement of asbestos shingles, slate surface, asphalt, stucco, brick or siding • Installation of new or replacement roofs • Demolition of a building or part of a building • The addition of closets • Installation of a dropped or suspended ceiling • Installation, replacement, changes to or additions
    [Show full text]