Be Lle M E a D E E0.0
Total Page:16
File Type:pdf, Size:1020Kb
(NOT ALL SYMBOLS (NOT ALL SYMBOLS LEGEND MAY BE USED) LEGEND MAY BE USED) SHEET INDEX Smith NUMBER SHEET NAME SYMBOL DESCRIPTION SYMBOL DESCRIPTION E0.0 ELECTRICAL LEGENDS, INDEX, AND NOTES Seckman E0.1 ELECTRICAL SCHEDULES Reid, Inc. LIGHTING MISCELLANEOUS EL1.1 ELECTRICAL LIGHTING FLOOR PLAN EP1.1 ELECTRICAL POWER FLOOR PLAN 2995 Sidco Drive XX 1 LIGHTING FIXTURE ANNOTATIONS (LOCATION OF DESIGNATORS MAY VARY) NON-FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING/POLES) EP2.1 ELECTRICAL POWER ROOF PLAN Nashville, TN 37204 FIXTURE TYPE: XX CIRCUIT NUMBER: 1 EY1.1 AUXILIARY SYSTEMS FLOOR PLAN (615) 383-1113 x FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING/POLES/FUSE SIZE) E5.1 ELECTRICAL DETAILS FAX: (615) 386-8469 CONTROL DESIGNATION: x E6.1 ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULES www.ssr-inc.com COMBINATION MOTOR STARTER/SAFETY SWITCH E7.1 BMS DIAGRAMS AND SCHEDULES bdg SURFACE, SUSPENDED, OR RECESSED LUMINAIRES E7.2 BMS MANUFACTURER'S DEVICE WIRING DIAGRAMS (TYPE DETERMINES MOUNTING) FACTORY WIRED CONTROLLER OR EQUIPMENT architects RECESSED OR SURFACE DOWNLIGHT LUMINAIRE J JUNCTION BOX 400 N. Ashley Dr., P: 813 - 323 - 9233 Ste. 600 Lic. #: AA - 0003590 PENDANT MOUNTED LUMINAIRE PANELBOARD Tampa, FL 33602 www.bdgllp.com WALLWASH LUMINAIRE BAS BUILDING AUTOMATION SYSTEM CONTROL PANEL WALL MOUNTED LUMINAIRES DR DOOR RELEASE PUSH BUTTON NO SHADING INDICATES CONNECTION TO NORMAL BRANCH CIRCUIT CR CARD READER SHADING INDICATES CONNECTION TO LIFE SAFETY OR EMERGENCY KP ELECTRONIC KEY PAD BRANCH CIRCUIT ILLUMINATED EXIT SIGNS, PROVIDE DIRECTIONAL ARROWS AND MOUNTING VFD VARIABLE FREQUENCY DRIVE GENERAL NOTES AS INDICATED ON PLANS A. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL BATTERY POWERED EMERGENCY LIGHT P PUSH PLATE (DOOR OPERATOR) EQUIPMENT INFORMATION. TRACK LIGHTING COMMUNICATIONS OUTLET - STANDARD MOUNTING HEIGHT, SPECIAL MOUNTING HEIGHT, CEILING B. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATIONS OF EQUIPMENT. POLE MOUNTED SITE LIGHTING LUMINAIRES MD MOTION DETECTOR C. PROVIDE CONNECTIONS FOR FIRE/SMOKE AND SMOKE DAMPERS. COORDINATE WITH MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND GROUND OR POLE MOUNTED FLOODLIGHT C SECURITY CCTV CAMERA - CEILING QUANTITIES OF DAMPERS. D. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND FAA SPECIALTY LIGHTING (TYPE DETERMINES MOUNTING) C SECURITY CCTV CAMERA - WALL QUANTITIES OF DUCT DETECTORS. FURNISH ONE DUCT DETECTOR FOR EACH FIRE/SMOKE AND EACH SMOKE DAMPER. RECEPTACLES ABBREVIATIONS 11 11 = CIRCUIT NUMBER (TYPICAL) DUPLEX RECEPTACLE - STANDARD MOUNTING HEIGHT AFF ABOVE FINISHED FLOOR XX XX= RECEPTACLE DESIGNATOR (TYPICAL) DUPLEX RECEPTACLE - ABOVE COUNTER OR SPECIAL MOUNTING HEIGHT CLG CEILING DOUBLE-DUPLEX RECEPTACLE COF COFFEE MACHINE DOUBLE-DUPLEX RECEPTACLE - ABOVE COUNTER OR SPECIAL MOUNTING HEIGHT COP COPIER DUPLEX GFCI RECEPTACLE CR CONTROLLED RECEPTACLE DUPLEX GFCI RECEPTACLE - CS CONTROLLED RECEPTACLE - SPLIT WIRED ABOVE COUNTER OR SPECIAL MOUNTING HEIGHT 4317 HARDING PIKE SWITCHED DUPLEX RECEPTACLE - 37205 NASHVILLE,TN DW DISHWASHER STANDARD MOUNTING HEIGHT Belle Meade Belle SPECIAL CONFIGURATION RECEPTACLE (TYPE AS NOTED) E EMERGENCY POWER FLOOR MOUNTED RECEPTACLE EPO EMERGENCY POWER OFF JPMChaseRetail Center Banking SWITCHES AND LIGHTING CONTROLS EV ELECTRICAL VEHICLE CHARGING STATION THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY SINGLE POLE SWITCH EWC ELECTRIC WATER COOLER CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER “PLANS”) ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESS JF 2 DOUBLE POLE, SINGLE THROW SWITCH FBO FURNISHED BY OTHERS WRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FOR CONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY 3 THREE-WAY SWITCH FLR FLOOR MOUNTED PURPOSE WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE 4 FOUR-WAY SWITCH ICE ICE MACHINE/MAKER EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANY DESIGN-RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE K SINGLE POLE SWITCH - KEY OPERATED IG ISOLATED GROUND ON THE PROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANY DISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE DIMMER SWITCH MW MICROWAVE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR D TO CONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITH LV LOW VOLTAGE SWITCH PR PRINTER THE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS. P SINGLE POLE SWITCH WITH PILOT LIGHT RF REFRIGERATOR SEAL OC OCCUPANCY SENSOR SWITCH, WALL MOUNT S SAFETY TYPE TC TIME CLOCK VD VACANCY DIMMER VC VACANCY SENSOR SWITCH TR TAMPER RESISTANT MOTOR RATED SWITCH WITH THERMAL OVERLOAD M TV TELEVISION TIMER SWITCH T URF UNDERCOUNTER REFRIGERATOR [email protected] VARIABLE INTENSITY SWITCH V USB RECEPTACLE WITH USB OUTLET(S) JOG SWITCH Architect of Record: J USBX USB ONLY (X) = NUMBER OF USB OUTLETS Christopher Gary Kirschner , AIA LEED AP TN License No. 103505 CIRCUIT BREAKER NOTES: CB VFD VARIABLE FREQUENCY DRIVE 1. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS AND BOTTOM OF LENS ADDITIONAL INFORMATION. ARCHITECTURAL ELEVATIONS SHALL GOVERN PC PHOTOCELL - CEILING / WALL MOUNT VM VENDING MACHINE ISSUE/BY DATE DESCRIPTION PC FOR SPECIAL MOUNTING HEIGHT RECEPTACLES AND SWITCHES. FIRE ALARM NOTIFICATION APPLIANCES OC OCCUPANCY SENSOR - CEILING / WALL MOUNT 2. COORDINATE ALL SPECIAL HEIGHT RECEPTACLES FOR TELEVISIONS WITH OC WP WEATHERPROOF MOUNTING BRACKET AND CATV OUTLET. DS DAYLIGHT SENSOR - CEILING / WALL MOUNT DS WC WATER COOLER 3. REFER TO LEGENDS FOR SYMBOLS NOT SHOWN. FIRE ALARM ABOVE COUNTER OR SPECIAL LIGHTING VC VACANCY SENSOR - CEILING / WALL MOUNT MANUAL PULL VC HEIGHT RECEPTACLES SWITCHES/ STATIONS (WHERE NO CASEWORK IS CONTROLS FIRE ALARM PRESENT, MOUNTING HEIGHT F CL AS NOTED) CL FIRE ALARM VISUAL DEVICE - STROBE ONLY PROJECT INFORMATION BLOCK CL JOB #: 19420750194012 FIRE ALARM AUDIO DEVICE WITH STROBE COUNTER, WORK SURFACE, 8" DATE: 08/30/2019 OR RIM OF WALL MOUNTED SINK. DRAWN BY: JF F CHECKED BY: JD FIRE ALARM MANUAL PULL STATION STANDARD HEIGHT 44" 48" 80" RECEPTACLES FAAP FIRE ALARM ANNUNCIATOR PANEL SHEET TITLE C:\Users\jfurr\Documents\SSR_Elec_Chase Bank Belle Belle Bank C:\Users\jfurr\Documents\SSR_Elec_Chase CL FACP FIRE ALARM CONTROL PANEL ELECTRICAL LEGENDS, FIRE ALARM SMOKE DETECTOR 18" XX NO SUBSCRIPT= IONIZATION TYPE; P= PHOTOELECTRIC; SS= SINGLE STATION SMOKE ALARM INDEX, AND NOTES FINISHED FLOOR SHEET NUMBER E0.0 8/29/2019 3:07:35 PM 3:07:35 8/29/2019 Smith Seckman Reid, Inc. LUMINAIRE SCHEDULE 2995 Sidco Drive Nashville, TN 37204 GENERAL NOTES: (615) 383-1113 1. REFER TO AND COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR FINAL FIXTURE LOCATIONS, HEIGHTS, CEILING TYPES, MOUNTINGS, FINISHES, ETC. 2. WHERE EMERGENCY BATTERY PACKS ARE INDICATED, THEY SHALL BE CONNECTED VIA UNSWITCHED PORTION OF ASSOCIATED CIRCUIT. FAX: (615) 386-8469 3. WHERE SUSPENDED FIXTURES ARE REQUIRED, REFER TO REFLECTED CEILING PLANS AND ELEVATIONS FOR MOUNTING HEIGHT TO PROVIDE PROPER LENGTH OF FIXTURE SUPPORT CABLE. UTILIZE ADJUSTABLE CABLE GRIPPERS FOR FINAL SETPOINT. ONCE FIXTURES ARE LEVELLED, REMOVE www.ssr-inc.com EXCESS CABLING. PROVIDE MATCHING FEED CANOPY AT EACH SUPPORT LOCATION AS DIRECTED BY ARCHITECT. bdg 4. WHERE FIXTURES ARE SHOWN IN CONTINUOUS ROW (I.E. COVES, SUSPENDED, UNDERCABINET, ETC.) PROVIDE 4' SECTIONS FOR MAIN RUNS AND SUPPLEMENT WITH SHORTER FIXTURE UNITS AT THE ENDS TO COMPLETELY FILL COVE AND/OR ROW LENGTH INDICATED. PROVIDE ALL NECESSARY CONNECTORS, EXTENSIONS, ADAPTERS, END CAPS, ETC., FOR A COMPLETE INSTALLATION. architects 400 N. Ashley Dr., P: 813 - 323 - 9233 Lic. #: AA - 0003590 LAMPS Ste. 600 Tampa, FL 33602 www.bdgllp.com TYPE DESCRIPTION MANUFACTURER/SERIES MIN. INPUT VOLTAGE BALLAST/DRIVER MOUNTING REMARKS QTY. LAMPS COLOR LUMENS WATTS L-2 2x2 RECESSED LENSED TROFFER GE LBT22A033MM835VQLTWHTE -- LED -- 3500K 34.0 120V LED DRIVER RECESSED -- L-3 (2) 19" UNDERCAB. LIGHT WITH OCCUPANCY SENSOR PHILIPS DAY-BRITE (2) LINCS100-L19-120-WHG-OSC -- LED -- 3500K 24.0 120V LED DRIVER SURFACE -- L-7 4" ROUND LENSED DOWNLIGHT - WET RATED GE DI4R10935 1V/2V 10 + RDI4RWPTWTWTWR + BH3 -- LED -- 3500K 14.0 120V LED DRIVER RECESSED PROVIDE BATTERY PACK FOR EMERGENCY FIXTURES AS INDICATED (OPTIONAL) ON PLANS. FIXTURES TO BE CONTROLLED VIA PHOTOCELLS. L-11 4" ROUND LENSED DOWNLIGHT GE DI4R10935 1V/2V 10 + RDI4RWPTWTWT + BH3 (OPTIONAL) -- LED -- 3500K 14.0 120V LED DRIVER AS REQUIRED PROVIDE BATTERY PACK FOR EMERGENCY FIXTURES AS INDICATED PER PLANS ON PLANS. L-20 SINGLE-FACE EXIT SIGN WITH 90-MIN. BATTERY BEST EZXTEU-1-RW-EMRC -- LED N/A N/A 3.0 UNIV LED DRIVER SEMI-RECESSED -- (AS REQUIRED PER PLANS) L-22B 2"x24" LENSED UTILITY LIGHT W/OCCUPANCY SENSOR LITHONIA ZL1N-L24-1500LM-FST-MVOLT-35K-80CRI-WH-LSXR -- LED -- 3500K 18.0 UNIV LED DRIVER WALL -- L-402 7"H x4"DIA ALINA PENDANT W/ STEEL BLUE AND WHITE GRADIENT TECH LIGHTING 700MPALIUS-LEDS830 -- LED -- SEE 8.0 120V LED DRIVER PENDANT 3000K GLASS GLOBE REMARKS L-403 ELEA 55 PENDANT LIGHT, BLACK LAQUER TECH LIGHTING 410232423U -- LED -- SEE 240.0 120V LED DRIVER PENDANT 3000K REMARKS L-405 3-PENDANT BLUE GLASS GLOBES, CANOPY FIXTURE BESA BES00298-174 -- LED -- SEE 15.0 120V LED DRIVER PENDANT 3-PENDANT BLUE GLASS GLOBES, CANOPY FIXTURE WITH INCLUDED REMARKS LED LAMPS SIMULATING INCANDESCENT LAMPS - SET CORD LENGTHS TO POSITION 5.5" DIA.