Scientific and Technical Report 2001 Volume VI Large Research Facilities

Total Page:16

File Type:pdf, Size:1020Kb

Scientific and Technical Report 2001 Volume VI Large Research Facilities PAUL SCHERRER INSTITUT ISSN 1423-7350 March 2002 Scientific and Technical Report 2001 Volume VI Large Research Facilities ed. by: Renate Bercher, Carmen Büchli, Lotty Zumkeller CH-5232 Villigen PSI Switzerland Phone: 056/310 21 11 Telefax: 056/31021 99 http://www.psi.ch I TABLE OF CONTENTS Foreword l Accelerator Physics and Development Operation of the PSI-accelerator facility in 2001 5 Progress in the production of the new ring cyclotron cavity 7 Coupled field analysis of the new ring cyclotron cavity 9 Experimental upgrade of the injector II150 MHz RF system 11 Replacement of magnet power supplies, control and field-bus for the PSI cyclotron accelerators 13 Investigations on discharges of high voltage devices based on a transient recorder program 15 Test of a radio-frequency-driven mulitcusp proton source 16 Emittance measurements at the PSI ECR heavy ion source 17 Profile measurement of scanning proton beam for LiSoR using carbon fibre harps 18 A fast dégrader to set the energies for the application of the depth dose in proton therapy 20 MAD9P a parallel 3D particle tracker with space charge 22 Behaviour of the different poisson solvers in the light of beam dynamics simulations 24 Computational electrodynamics on the LINUX-cluster 26 Particle ray-tracing program TRACK applied to accelerators 27 Experimental Facilities Rebuilt beam line section between the targets M and E 31 Disposal preparation for meson production targets 33 A novel method to improve the safety of the planned MEGAPIE target at SINQ 34 Beamline adaptation for the MEGAPIE-target 36 Programme "TUR" and two uniform number generators 37 Conceptual design of the spallation target for the ultra cold neutron source UCN 38 Shielding and activation calculations for an ultracold neutron facility at PSI 41 A rotating filter for the materials science beamline of the SLS 43 Spallation Neutron Source The Spallation Neutron Source Division ASQ: An overview 47 From the Kantonsschule to the MEGAPIE-project 50 Status of the MEGAPIE-project and the international collaboration 51 Configuration optimisation of concave target safety enclosures 53 Hypothetical accident analysis on falling container of the MEGAPIE-target 55 Heat transfer in the case of leaking target material 57 Influence of freezing of Lead-Bismuth Eutectic on the strain distribution in a model container 59 Volume change of LBE after solidification 61 Calculated power deposition in the liquid lead bismuth and target lower enclosures of the MEGAPIE target 63 KILOPIE - Design of a thermal hydraulic experiment for the MEGAPIE target window 65 Tensile testing of MANET II in flowing Pb-Bi at elevated temperature in LiSoR loop 67 SINQ target irradiation programs, STIP-II and STIP-III 69 Temperature dependence of the microstructure of high energy proton irradiated F82H martensitic steel 71 Tensile properties of T91 irrdiated at SINQ-target MARK-II to 10 dpa 73 Liquid metal loop LiSoR 74 Stress wave experiments with the ASTE mercury spallation target 75 Status of the strain-field diffractometer POLDI 77 Experiments on the magnetic flux line lattice in the high temperature superconductor YBCO in high magnetic fields 78 Applied energy-selective neutron radiography and tomography at the PGA station 79 Neutron radiography with fast neutrons at 14-MeV accelerator source 81 Investigation of the hydrogen accumulation in the cladding material of nuclear fuel by neutron radiography 83 Dynamic behaviour of the water distribution in wet aramid-based ballistic body armour panels investigated by neutron radiography 85 II Setup of CCD based detection system at the NCR station 86 3D investigations of pore size distribution in sandstone 87 Selective radiography of 10B distribution in organs using cold and thermal neutron beams 88 On-line gamma-spectrometric measurements of short-lived radioisotopes inmigration experiments at the Grimsel Test site 89 Characterisation of thermally sprayed deposits, treated by hot isostatic pressing (HIP) 90 Characterization of void morphologies in thermally sprayed metallic deposits using scattering techniques 91 Intergranular fracture in nanocrystalline metals 93 Computer simulation of displacement cascades in nanocrystalline metals 94 Structural and mechanical properties of nanocrystalline FCC metals 95 Low-frequency vibrational properties of nanocrystalline materials 97 Atomistic simulations of nanoindentation in interface dominated materials 98 Microstructural analysis of electrodeposited and severe plastically deformed Ni and their mechanical behaviour.... 99 Structure of lipid bilayers of dimeric ionpaired amphiphiles 101 Role of counterion distribution on the structure of micelles in aqueous salt solution 102 Technical Support and Co-ordination Versatility of the ATK division 105 The PROSCAN project: a progress report 109 List of publications 111 Contributions to conferences and workshops 115 Lectures and courses 122 Dissertations 123 Members of scientific committees 123 Awards 124 Reports / books 124 Chapter in book 124 1 Wildenstein, a strong• of operation, during which 10Ah of beam have been hold dating back to the accumulated, we will prophylactically replace the spallation 13th century, was the target with a new one of the same type. At the same time, meeting place for a one- we will be able to examine the materials, which have been day workshop in June exposed to this intense radiation dose. 2001 on measures to improve the availability Besides our work on maintenance and improvement of of our proton accelera• existing equipment, we are also involved in new and novel tors and their auxiliary enterprises. Just a few days before Christmas, our strain systems. Although we field diffractometer POLDI saw its first neutrons; LISOR, a do not expect our unique apparatus to test corrosion effects and liquid metal facilities to be still embrittlement under radiation at elevated temperatures, was operational 700 years from now, we felt that similarities in completed and installed on an Injector 1 proton beam line. the history, albeit on different time scales, of the stronghold We have also been heavily involved in the PROSCAN and our accelerators might be a nice symbol of our project, which comprises a novel superconducting cyclo• endeavor. Both places have changed their purpose over the tron, beam Unes to the existing and also to a new gantry for years: Wildenstein from a stronghold of local knights to a an efficient and improved proton therapy program. Thanks gathering place of Swiss troops against the armies of the to the comprehensive expertise of our staff, a first-rate French king and later to a summer resort and meeting place; accelerator could be designed and ordered from a European our research facility from an instrument to study industrial company in collaboration with fellow institutes. fundamental forces of nature to a multipurpose facility, We could also find an excellent solution for the beam lines which is also used for research in materials sciences and for and shielding in a difficult topology. Progress has been medical applications. The secret of longevity of castle and made in the MEGAPIE project, which will eventually allow accelerator is adaptation to new needs and intensive and us to substantially increase the SINQ neutron flux by careful maintenance. utilizing liquid lead bismuth eutectic as target material. Although the retirement of the initiator and technical While the main effort in the past ten years was directed project director of this large international collaboration, Dr. Guenter Bauer, appeared to be a serious setback, we could towards increasing the beam current from 100 to 2000 uA fortunately acquire two competent and enthusiastic and installation of additional user facilities like SINQ to collaborators as technical manager and controller. Besides satisfy new needs, we are now concentrating on stable our intensive support of SLS, including experimental operation at these high beam intensities. Unfortunately, equipment, there are a number of projects from other "stable operation" is not clearly defined. A few years ago, departments such as the ultracold neutron source UCN, the the accelerator physicists considered 80% beam on time low energy muon beam LEM, assembly of a fuel cell excellent but the users complained about poor performance. powered car and handling and disposal of radioactive Today we achieve a yearly mean beam on time of almost waste, where we deliver important technical and scientific 90% at 1.7 mA and we have achieved 95% to 98% of the contributions. scheduled beam time for periods of weeks. These numbers seem to be satisfactory for the users. Despite this achievement, we try hard to further reduce the number of Even though our main task remains the operation and serious and long breakdowns, which are the main cause of improvement of the large accelerator facilities, we also the reduced yearly mean availability. Furthermore, work on or collaborate in research projects. Only a fraction breakdowns that necessitate long repair times are extremely of our workforce can be devoted to these activities, but this detrimental for many experiments, which have only been fraction provides an essential motivation for the scientific allocated a few days of beam time. As a result of our personnel and it also has a big impact on our understanding discussions, we launched a number of activities, which and fulfillment of the requirements of research at our include design and construction of improved power facilities. As a direct consequence of theoretical studies
Recommended publications
  • Imagepresentation (PDF, 76 Pages, 8.9
    THE CANTON OF AARGAU: ECONOMY AND EMPLOYMENT The Canton of Aargau is situated in Switzerland’s strongest economic area. Some 340 000 people are employed here in around 40 000 companies. An above-average proportion of these workers are active in the field of research and development. In fact, this is more than twice the national average. Our economic, tax and financial policies make the Canton of Aargau an attractive place of business for international corporations as well as for small and medium-sized businesses. The innovative Robotec Solutions AG known as a leading enterprise in robot applications. Standard & Poor’s has awarded the Canton of Aargau the rating AA+. And it’s no wonder. After all, we have a low unemployment rate, a moderate taxation rate, a strong economy and a high standard of living. These factors appeal to many well-known companies operating here in a wide range of industries – including ABB, GE, Franke, Syngenta and Roche. Our media landscape is equally diverse. In addition to AZ Medien, the canton boasts numerous other well-positioned local media companies. THE CANTON OF AARGAU: LIFE AND LIVING SINA SINGER The Canton of Aargau is currently home to some 670 000 people. That makes us the fourth-largest canton in Switzerland. Aargau is an urban area, yet also modest in size. The Canton of Aargau is within reasonable distance of anywhere – whether by car or public transport. However, for those who prefer to stay and be part of the local scene, Aargau has well-established communities and a wealth of vibrant traditions.
    [Show full text]
  • Particle Accelerator Activities at the Paul Scherrer Institut
    PSI Bericht Nr. 17-07 December 2017 Particle Accelerator Activities at the Paul Scherrer Institut Terence GARVEY Paul Scherrer Institut, Villigen, Switzerland 5232 Division of Large Research Infrastructures Invited paper presented at Les Journées Accélérateurs de la Société Française de Physique, Roscoff, 3rd – 6th October, 2017. Resumé Les Activités Accélérateur à l’Institut Paul Scherrer. L'Institut Paul Scherrer exploite deux complexes d'accélérateurs en tant que ‘centre- serveurs’ pour une grande communauté de chercheurs. Il s'agit de l'Accélérateur de Protons à Haute Intensité (HIPA) et de la Source de Lumière Suisse (SLS). HIPA est un cyclotron à protons de 590 MeV. Il sert à produire des neutrons par spallation pour la recherche en physique de la matière condensée et à produire des muons et d'autres particules secondaires pour la recherche en magnétisme et en physique des particules. Le SLS est un anneau de stockage d’électrons de 2,4 GeV utilisé comme source de rayonnement synchrotron de 3ème génération fournissant des photons pour une large gamme de disciplines scientifiques. En plus de ces deux installations, l'Institut met progressivement en service un laser à électrons libres en rayons X (SwissFEL) qui fournira aux chercheurs des impulsions femto-seconde intenses à partir d’une ligne de rayons X ‘dur’ (ARAMIS) et de rayons X ‘mou’ (ATHOS). L'Institut exploite également un cyclotron supraconductrice à 250 MeV (COMET) aux fins de la thérapie par proton. Le centre de thérapie a récemment été équipé d'un troisième « gantry » rotatif qui est en cours de mise en service. Un « upgrade » du système de radiofréquence de HIPA et des projets pour "SLS-2" seront présentés.
    [Show full text]
  • Footnotes for ATOMIC ADVENTURES
    Footnotes for ATOMIC ADVENTURES Secret Islands, Forgotten N-Rays, and Isotopic Murder - A Journey into the Wild World of Nuclear Science By James Mahaffey While writing ATOMIC ADVENTURES, I tried to be careful not to venture off into subplots, however interesting they seemed to me, and keep the story flowing and progressing at the right tempo. Some subjects were too fascinating to leave alone, and there were bits of further information that I just could not abandon. The result is many footnotes at the bottom of pages, available to the reader to absorb at his or her discretion. To get the full load of information from this book, one needs to read the footnotes. Some may seem trivia, but some are clarifying and instructive. This scheme works adequately for a printed book, but not so well with an otherwise expertly read audio version. Some footnotes are short enough to be inserted into the audio stream, but some are a rambling half page of dense information. I was very pleased when Blackstone Audio agreed wholeheartedly that we needed to include all of my footnotes in this version of ATOMIC ADVENTURES, and we came up with this added feature: All 231 footnotes in this included text, plus all the photos and explanatory diagrams that were included in the text. I hope you enjoy reading some footnotes while listening to Keith Sellon-Wright tell the stories in ATOMIC ADVENTURES. James Mahaffey April 2017 2 Author’s Note Stories Told at Night around the Glow of the Reactor Always striving to beat the Atlanta Theater over on Edgewood Avenue, the Forsyth Theater was pleased to snag a one-week engagement of the world famous Harry Houdini, extraordinary magician and escape artist, starting April 19, 1915.1 It was issued an operating license, no.
    [Show full text]
  • Gold Embrittlement of Solder Joints 2018.Pages
    Gold Embrittlement of Solder Joints Ed Hare, PhD - SEM Lab, Inc 425.335.4400 [email protected] Introduction Gold embrittlement of solder joints has been written about for at least four decades [1 – 3]. Nevertheless, gold embrittlement related solder joint failures have been analyzed in this laboratory as recently as July 2009. Gold embrittlement can be avoided by careful solder joint design and knowledge of the causes of this condition. The purpose of this paper is to provide a detailed account of material and process parameters that can lead to gold embrittlement in electronic assemblies. There are a variety of reasons that designers might want to solder to gold or gold plating. One reason is that some designs involve wire bonding and soldering operations on the same assembly. Another reason would be to include gold contact pads (e.g. for dome keypad contacts) or card edge contacts (e.g. PC cards). The wire bond pads or contact pads can be selectively gold plated, but the selective plating process can be expensive. The electronics industry currently recognizes a threshold level for gold that can be dissolved into eutectic tin-lead solder above which the solder is likely to become embrittled. This threshold is ~ 3 wt% gold. It will be shown in the paragraphs below that embrittlement of solder joints can develop at significantly lower bulk gold concentrations. Metallurgical Description of Gold Embrittlement The most important soldering alloy in the electronics industry is the eutectic tin-lead alloy, 63%Sn – 37%Pb. This may change in the near future as lead-free soldering takes its hold on the industry.
    [Show full text]
  • Targeted Radiotherapeutics from 'Bench-To-Bedside'
    RadiochemistRy in switzeRland CHIMIA 2020, 74, No. 12 939 doi:10.2533/chimia.2020.939 Chimia 74 (2020) 939–945 © C. Müller, M. Béhé, S. Geistlich, N. P. van der Meulen, R. Schibli Targeted Radiotherapeutics from ‘Bench-to-Bedside’ Cristina Müllera, Martin Béhéa, Susanne Geistlicha, Nicholas P. van der Meulenab, and Roger Schibli*ac Abstract: The concept of targeted radionuclide therapy (TRT) is the accurate and efficient delivery of radiation to disseminated cancer lesions while minimizing damage to healthy tissue and organs. Critical aspects for success- ful development of novel radiopharmaceuticals for TRT are: i) the identification and characterization of suitable targets expressed on cancer cells; ii) the selection of chemical or biological molecules which exhibit high affin- ity and selectivity for the cancer cell-associated target; iii) the selection of a radionuclide with decay properties that suit the properties of the targeting molecule and the clinical purpose. The Center for Radiopharmaceutical Sciences (CRS) at the Paul Scherrer Institute in Switzerland is privileged to be situated close to unique infrastruc- ture for radionuclide production (high energy accelerators and a neutron source) and access to C/B-type labora- tories including preclinical, nuclear imaging equipment and Swissmedic-certified laboratories for the preparation of drug samples for human use. These favorable circumstances allow production of non-standard radionuclides, exploring their biochemical and pharmacological features and effects for tumor therapy and diagnosis, while investigating and characterizing new targeting structures and optimizing these aspects for translational research on radiopharmaceuticals. In close collaboration with various clinical partners in Switzerland, the most promising candidates are translated to clinics for ‘first-in-human’ studies.
    [Show full text]
  • FTC Guideline - Title 16, Commercial Practices Part 23 for Gold Plating Over Sterling Silver Jewelery
    Reference: FTC guideline - Title 16, commercial practices part 23 for gold plating over sterling silver Jewelery Dear Sir, My concern is on low K gold plating (10/14/18) over sterling silver. As per me, gold plating on silver Jewellery should be done only with > 23K. Following are the reasons to support my recommendation: REASONS TO AVOID LOW K GOLD PLATING • In low karat gold micron electroplating, we have to use either Au/Cu or Au/Ag chemistry. Au/Cu chemistry plating color for 14K is too pink (5N) & Au/Ag chemistry plating color is too green. We have to give top coat of 0.1 micron of high karat gold (>23K) to achieve Hamilton color (1N/2N) over low karat gold plating. • Doing low karat gold plating & cover it with nominal high karat gold for color, deficit the purpose of gold plated Jewellery. If the top flash gold will wear out then actual gold alloy color (pink/green) will expose (pink/green) which will tarnish too fast. • Achieving exact K (10/14/18) in low K electroplating is practically not possible. • We cannot identify gold purity of plating thickness on sterling silver by XRF because there are common elements present in plating thickness & base (e.g. Ag,Cu..). • Gold alloy (10/14/18) thickness testing is not possible by XRF because standards available for thickness calibration are in 24K. It is impossible to make 10/14/18 K standards as per plating compositions (Au/Cu & Au/Ag) because it cannot be fabricated. Thickness measurement of low K on XRF is manipulated method, where instrument detects pure gold ions throughout the plating layer & then by density calculation it will be converted into low K plating thickness(e.g.- 14 K density is 13 g/cc & pure gold is 19.3 g/cc.
    [Show full text]
  • Understanding Gold Plating
    Understanding Gold Plating Peter Wilkinson Engelhard Limited, Cinderford, Gloucestershire, United Kingdom For effective operation, gold plating baths must require the mini- mum of attention in respect of replenishment and replacement, and must produce as little sub-standard or reject work as possible. To achieve this, an understanding of the processes involved and the factors affecting them is advantageous. This article attempts to provide such an understanding in a simple manner. Special atten- tion is given to the plating of gold from acid baths containing monovalent gold complexes. The use of gold as a contact material on connectors, Other gold(I) complexes, such as those with thiomalate and switches and printed circuit boards (PCB's) is now well estab- thiosulphate have been considered, but it is doubtful if they lished. There is also an awareness that only gold deposits from will ever find commercial application. acid (pH 3.5-5.0) gold(I) cyanide baths containing cobalt, In terms of electricity consumed, gold(I) baths are more nickel or iron as brightening agents have the appropriate efficient than gold(III) baths. Thus, assuming 100 per cent properties for a contact material. Gold deposits from: pure efficiency, 100 amp-min will deposit 12.25 g of gold from a gold(I) cyanide baths; from such baths containing organic monovalent gold complex, but only 4.07 g from a trivalent gold materials as brightening agents; or from electrolytes containing complex. gold in the form of the gold(I) sulphite complex, do not have Nevertheless, deposition from acid gold(III) cyanide baths the sliding wear resistance which is necessary for make and has merit in the plating of acid resistant substrates such as stain- break connections (1).
    [Show full text]
  • Challenges on ENEPIG Finished Pcbs: Gold Ball Bonding and Pad Metal Lift
    As originally published in the IPC APEX EXPO Proceedings. Challenges on ENEPIG Finished PCBs: Gold Ball Bonding and Pad Metal Lift Young K. Song and Vanja Bukva Teledyne DALSA Inc. Waterloo, ON, Canada Abstract As a surface finish for PCBs, Electroless Nickel/Electroless Palladium/Immersion Gold (ENEPIG) was selected over Electroless Nickel/Immersion Gold (ENIG) for CMOS image sensor applications with both surface mount technology (SMT) and gold ball bonding processes in mind based on the research available on-line. Challenges in the wire bonding process on ENEPIG with regards to bondability and other plating related issues are summarized. Gold ball bonding with 25um diameter wire was performed. Printed circuit boards (PCBs) were surface mounted prior to the wire bonding process with Pb-free solder paste with water soluble organic acid (OA) flux. The standard gold ball bonding process (ball / stitch bonds) was attempted during process development and pre-production stages, but this process was not stable enough for volume production due to variation in bondability within one batch and between PCB batches. This resulted in the standard gold ball bonding process being changed to stand-off-stitch bonding (SSB) or the ball-stitch-on-ball (BSOB) bonding process, in order to achieve gold ball bonding successfully on PCBs with an ENEPIG finish for volume production. Another area of concern was pad metal lifting (PML) experienced on some PCBs, and PCB batches, where the palladium (Pd) layer was completely separated from nickel (Ni) either during wire bonding or during sample destructive wire pull tests, indicating potential failures in the remainder of the batch.
    [Show full text]
  • The Early History of Gold Plating
    The Early History of Gold Plating A TANGLED TALE OF DISPUTED PRIORITIES L. B. Hunt Johnson Matthey & Co Limited, London "The gilding of metals is, of all the processes whose object is to obtain an adhering deposit, the one which has exercised in the greatest degree the sagacity of inventors " PROFESSOR AUGUSTE DE LA RIVE, GENEVA, 1840 Many of the scientfic discoveries and technical President of the Royal Society, Sir Joseph Banks. developments that were so characteristic of the Because the letter would have to pass through nineteenth century rapidly became the subject of France, then engaged in the Napoleonic wars with controversy and of heated arguments about priorities. England, Volta sent only the first part of the letter, Of all these, none was probably more sorely beset by the second part following three months later, so that polemics and acrimonious debate—or for a longer it was not read to the Royal Society until the end period of time—than the birth of a commercially of June of that year. None the less, the receipt of satisfactory process for the electrodeposition of gold the earlier part of the letter was enough to cause (and of silver with which it was naturally associated) considerable excitement among the scientists of the on to base metals. It must also come close to world period, since it now made available for the first time record standards for the number and the diversity of a low voltage continuous current as opposed to the the scientists and dilettante whose contributions high voltage discharges, lasting only a fraction of a eventually led to success; not only were there second, from the static electrical machines.
    [Show full text]
  • Gold Plating of Critical Components for Space Applications: Challenges and Solutions
    GOLD PLATING OF CRITICAL COMPONENTS FOR SPACE APPLICATIONS: CHALLENGES AND SOLUTIONS Indira Rajagopal, K.S. Rajam er S.R. Rajagopalan Materials Science Division National Aeronautical Laboratory Bangalore 560017 India Ensuring the maximum reliability of the gold plating on lightweight alloys used in space applications is a difficult and challenging task. In this article, the authors describe the processes that they have found to meet requirements. Aluminium, magnesium, titanium and their alloys oxide film which prevents metal-to-metal bonding, are increasingly used as the lightweight structural thus leading to poor adhesion. materials in aircraft and space applications, where light- For space applications, the reliability of the ness is always at a premium. To meet the end require- plating should be 100 %. This means that the adhe- ments (e.g., for improving corrosion and wear resis- sion should be excellent and high quality deposits tance, for increasing surface conductivity, for thermal should be produced. Defective plating is unaccept- control, etc.) surface coatings are applied to modify able as it seriously affects the launching and/or func- the surface properties. tioning of the spacecraft. Stripping the defective Unfortunately, plating on these lightweight struc- deposits without damaging the sensitive compo- tural materials is difficult. These metals and alloys nents also poses problems. Hence it is mandatory belong to the group of difficult-to-plate materials. The to control deposit characteristics with very high re- basic problem stems from their high electrochemical liability by surface preparation procedures, by potential in aqueous solution and their consequent careful selection and control of bath composition high reactivity in air even at room temperature.
    [Show full text]
  • Corrosion Protection of Electrically Conductive Surfaces
    Metals 2012, 2, 450-477; doi:10.3390/met2040450 OPEN ACCESS metals ISSN 2075-4701 www.mdpi.com/journal/metals/ Article Corrosion Protection of Electrically Conductive Surfaces Jian Song *, Liangliang Wang, Andre Zibart, Christian Koch Precision Engineering Laboratory, Ostwestfalen-Lippe University of Applied Sciences, Liebigstrasse 87, 32657 Lemgo, Germany; E-Mails: [email protected] (L.W.); [email protected] (A.Z.); [email protected] (C.K.) * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +49-177-2131820; Fax: +49-5261-702263. Received: 19 June 2012; in revised form: 10 September 2012 / Accepted: 1 November 2012 / Published: 15 November 2012 Abstract: The basic function of the electrically conductive surface of electrical contacts is electrical conduction. The electrical conductivity of contact materials can be largely reduced by corrosion and in order to avoid corrosion, protective coatings must be used. Another phenomenon that leads to increasing contact resistance is fretting corrosion. Fretting corrosion is the degradation mechanism of surface material, which causes increasing contact resistance. Fretting corrosion occurs when there is a relative movement between electrical contacts with surfaces of ignoble metal. Avoiding fretting corrosion is therefore extremely challenging in electronic devices with pluggable electrical connections. Gold is one of the most commonly used noble plating materials for high performance electrical contacts because of its high corrosion resistance and its good and stable electrical behavior. The authors have investigated different ways to minimize the consumption of gold for electrical contacts and to improve the performance of gold plating. Other plating materials often used for corrosion protection of electrically conductive surfaces are tin, nickel, silver and palladium.
    [Show full text]
  • Research at the Paul Scherrer Institut
    390 FR9807042 Research at the Paul Scherrer Institut H. K. Walter Paul Scherrer Institut, PSI - West, CH- 5232 ViUigen, Switzerland Abstract The Paul Scherrer Institut (PSI) is a multidisciplinary research institute for natural sciences and technology. In national and international collaboration with universities, other research institutes and industry, PSI is active in elementary particle physics, life sciences, solid-state physics, material sciences, nuclear and non-nuclear energy research, and energy-related ecology. PSI's priorities lie in research fields which are relevant to sustainable development, serve educational needs and are beyond the possibilities of a single university department. PSI develops and operates complex research installations open to a national and international scientific community. With the upgrade of the 590 MeV Ring accelerator PSI disposes of the world's most powerful cyclotron, allowing to operate high intensity secondary pion and muon beams, a neutron spallation source and various applications in medicine and materials research. A short review on research at PSI is presented, with special concentration on particle physics experiments. Introduction therapy) presently in the construction or planning As a national research center for natural and phase. The facilities are described in the new Users' engineering sciences, PSI is governed by the same Guide [1] and shown in Figure 1. authority as the two technical high schools in Zurich The accelerators and experimental areas and Lausanne. The budget in 1995 was around 160 MSFr, and there are about 1100 employees, including The cyclotron facility was originally built to produce 200 persons paid by non - PSI funds. Research is done intense beams of pions and muons for nuclear and with the Swiss universities, in close collaboration with particle physics experiments.
    [Show full text]