Air-Insulated Medium-Voltage Switchgear Nxairs, 24Kv
Total Page:16
File Type:pdf, Size:1020Kb
Air-insulated Medium-Voltage Switchgear NXAirS, 24kV siemens.com.cn/energy-management Air-insulated Medium-Voltage Switchgear NXA irS,24kV Contents Application Types Application Circuit-breaker switchgear NXAirS, is factory-assembled, type-tested, Types metal-enclosed and metal-clad switchgear for indoor installation accoording Typical uses to GB3906, DL404 and IEC 62271-200.. Classification Loss of service continuity category LSC2B (Metal clad) Partition class PM(Metal) Requirements Internal arc classification IAC A FLR ISC≤31.5kA Customer benefits and features arc duration=1s Technical Data Electrical data and dimensions Design data Transportation and packing Primary Solution NXAirS 24kV Design Design of switchgear Components Vacuum circuit-breaker Standards Standards, specifications, guidelines NXAirS panel Maxium rating 24kV/31.5kA/3150A 2 Air-insulated Medium-Voltage Switchgear NXA irS,24kV Air-insulated Medium-Voltage Switchgear NXAirS,24kV Contents Application Application Types Application Typical uses Classification Application Circuit-breaker switchgear NXAirS, is factory-assembled, type-tested, NXAirS circuit-breaker switchgear is used in NXAirS switchgear correspond to the following classifications according to GB3906, Types metal-enclosed and metal-clad switchgear for indoor installation accoording Typical uses substations and distribution system, mainly at the DL404 and IEC62271-200. to GB3906, DL404 and IEC 62271-200.. Classification primary distribution level. E.g. Loss of service continuity category Loss of service continuity category LSC2B (Metal clad) and partition class Partition class PM(Metal) Loss of service continuity category LSC 2B (Metal clad) Requirements Application Public power supply system Internal arc classification IAC A FLR ISC≤31.5kA Customer benefits and features arc duration=1s • Power supply companies Partition class PM (Metal) Accessibility to compartments Technical Data Application Industry Busbar compartment Tool-based Electrical data and dimensions • Power plant Switching-device compartment Interlock-based Design data Transportation and packing • Cement industry Connection compartment Interlock-based and use special tools • Automobile industry Primary Solution • Iron and steel works Internal arc classification NXAirS 24kV • Mining industry The following internal arc classification • Textile, paper and food industries are fulfilled Design • Chemical industry IAC A FLR, I , t Design of switchgear SC • Petroleum industry IAC =Internal arc classification • Pipeline installations Components A =300mm distance of indicators for test • Offshore oil devices (installation in closed electrical service Vacuum circuit-breaker • Electrochemical plants location) F =Front arrangement of indicators for test Standards • Petrochemical plants Standards, specifications, guidelines • Diesel power plants L =Lateral arrangement of indicators for test =Rear arrangement of indicators for • Emergency power supply devices R test • Coal exploitation ISC =Test current for NXAirS up to 31.5kA t =Arcing time 1s In this way, NXAirS is suitable for unrestricted application (wall or free- standing arrangement) in electrical service locations up to the maximum short-circuit current rating. NXAirS panel Maxium rating 24kV/31.5kA/3150A 2 3 Air-insulated Medium-Voltage Switchgear NXAirS,24kV Requirements Customer benefits and features Benefits Features Peace of mind • Type-tested switchgear according to GB, DL and IEC standard. For power supply companies and • Independent pressure-resistant partitions for each compartment. industrial plants, the certification • Use of maintenance-free vacuum circuit breakers. of NXAirS according to the latest • Type testing of the vacuum circuit breaker. standards has very concrete • Pressure-resistant partitions. a d v a n t a g e s , w h o s e s m o o t h • Use of standard, worldwide available components. operation provide maximum • Quality management according to ISO9001. safety for users. Saves Lives • All switching operations with high-voltage door closed. All switchgear types of the NXAirS • Metallic enclosure, earthed shutters and partitions. family are approved with internal • Reliable interlock mechanism installed on high voltage door. arc classification IAC A FLR, loss of • Switchgear with internal arc classfication according to IAC A FLR. service continuity category LSC 2B, • Loss of service continuity category LSC2B. partition class PM. This makes them • Busbar, cable connection and switching-device compartments are divided into independent suitable for universal installtion, compartment. meeting the highest requirements • Use of vacuum circuit breakers. regarding personal safety. • Standard degree of protection IP4X. • Shutters of busbar compartment cover the stationery contact for preventing electric shock to maintainer. • Reliable mechanical interlocking system. Save money • Stable insulation performance—the use of embedded pole type VCB avoids the environment The adoption of newly designed influence maximumly. 3AE maintenace-free embedded • Constant contact resistance—the absence of oxidation in a vacuum keeps the metal contact pole breaker enable continuous surfaces clean. For this reason, contact resistance can be assured to remain low throughout the operation without expensive service life of the equipment. shutdown times. • Large total breaking times—Under the rated normal current, the breaker can be interrupted up to 30,000 times. • Maintenance-free within 10,000 times operation cycles—throughout its entire service life, the vacuum interrupter operates reliably at all times—without any forms of maintenance within 10,000 times operation or 10 years. The arc voltage is thus extremely low-only 20 to 200V. And, on account of short arcing times of max. 15ms, the energy consumption in the contact gap is very low. 4 Air-insulated Medium-Voltage Switchgear NXAirS,24kV Air-insulated Medium-Voltage Switchgear NXAirS,24kV Requirements Technical Data Customer benefits and features Electrical Data and Dimensions Benefits Features Rated values Peace of mind • Type-tested switchgear according to GB, DL and IEC standard. For power supply companies and • Independent pressure-resistant partitions for each compartment. -rated voltage kV 24 industrial plants, the certification • Use of maintenance-free vacuum circuit breakers. -rated frequency Hz 50 of NXAirS according to the latest • Type testing of the vacuum circuit breaker. -short-duration power frequency withstand voltage (phase- kV 65/79 to-phase, phase-to-earth) standards has very concrete • Pressure-resistant partitions. -lightning impulse withstand voltage (phase-to-phase, phase- kV 125/145 a d v a n t a g e s , w h o s e s m o o t h • Use of standard, worldwide available components. to-earth) operation provide maximum • Quality management according to ISO9001. -short-circuit breaking current (max.) kA 25,31.5 safety for users. -short-time withstand current, 4s (max.) kA 25,31.5 , Saves Lives • All switching operations with high-voltage door closed. -short-circuit making current (max.) kA 63 80 All switchgear types of the NXAirS • Metallic enclosure, earthed shutters and partitions. -peak withstand current (max.) kA 63,80 family are approved with internal • Reliable interlock mechanism installed on high voltage door. -busbar current A 1250, 2000, 2500,3150 arc classification IAC A FLR, loss of • Switchgear with internal arc classfication according to IAC A FLR. -Feeder current A 1250, 2000, 2500,3150 service continuity category LSC 2B, • Loss of service continuity category LSC2B. partition class PM. This makes them • Busbar, cable connection and switching-device compartments are divided into independent Dimension suitable for universal installtion, compartment. Width W mm 1000 meeting the highest requirements • Use of vacuum circuit breakers. Height mm 2854/2620/2695 regarding personal safety. • Standard degree of protection IP4X. • Shutters of busbar compartment cover the stationery contact for preventing electric shock to Depth D mm 1810/1848 maintainer. Weight kg 900~1300 • Reliable mechanical interlocking system. Save money • Stable insulation performance—the use of embedded pole type VCB avoids the environment The adoption of newly designed influence maximumly. 3AE maintenace-free embedded • Constant contact resistance—the absence of oxidation in a vacuum keeps the metal contact Dimension of low-voltage compartment pole breaker enable continuous surfaces clean. For this reason, contact resistance can be assured to remain low throughout the operation without expensive service life of the equipment. Standard shutdown times. • Large total breaking times—Under the rated normal current, the breaker can be interrupted up to Width mm 1000 30,000 times. Height mm 630 • Maintenance-free within 10,000 times operation cycles—throughout its entire service life, the Depth mm 400 vacuum interrupter operates reliably at all times—without any forms of maintenance within 10,000 times operation or 10 years. The arc voltage is thus extremely low-only 20 to 200V. And, on account of short arcing times of max. 15ms, the energy consumption in the contact gap is very Dimension of connection compartment low. Width mm 1000 Height mm 1150 Cable terminal to earth mm ≥750 4 5 Air-insulated Medium-Voltage Switchgear NXA irS,24kV Technical Data Design data Structure view of panel body • Please consult for low indoor height. • A passage with 1200mm width must be avaibable alongside the panel so as to push the withdrawable part into this 4 5 8 2 passage.