Electrical Level 3
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Ecm Operation Manual
ECM OPERATION MANUAL FOR USE WITH MODELS: OL11-105FDBE OL16-125FDBE OL11-105RDBE OL16-125RDBE : IF YOU DO NOT FOLLOW THE SAFETY PRECAUTIONS BELOW AND IN THIS MANUAL, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. (REFERRED TO IN THESE INSTRUCTIONS AS A QUALIFIED HEATING CONTRACTOR). PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE HOMEOWNER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL. THERMO PRODUCTS, LLC. BOX 237 DENTON, NC 27239 PHONE: 800-476-4328 MADE IN USA MO-507 ECN 5577-MA 190924 All installations and services must be performed by qualified service personnel. INDEX SECTION BEGINNING PAG I. BLOWER CONTROL INFORMATION 1 A. TERMINAL DEFINITIONS & FIELD WIRING 1 B. WIRING & SWITCHES 2 C. INPUTS 4 D. OUTPUTS 4 E. OPERATING MODES 5 F. CFM TABLES 7 G. ECM SPECIFIC REPLACEMENT PARTS 8 III. ECM TROUBLESHOOTING 8 A. DIAGNOSTIC FEATURES 8 B. GENERAL GUIDELINES TO TROUBLESHOOTING GE ECM 9 C. TROUBLESHOOTING CHARTS 12 i i All installations and services must be performed by qualified service personnel. I. BLOWER CONTROLLER INFORMATION A. TERMINAL DEFINITIONS & FIELD WIRING Burner Harness Connector P1 Pin 1 – Limit switch connection. Pin 2 – 120 VAC Line connection. Pin 3 – Burner pilot contact. Pin 4&5 – 120 VAC Neutral connection. -
Installation & Operation Guide
Operation I/O Descriptions • Intended for use with 3-Phase, 50/60Hz • Accepts 208-600VAC, +10% Use 14-26AWG wire for I/O Terminals, Torque to 3.5 lb-in • Short Circuit (RMS, Symmetrical) Stand-Alone Overload Unit - 200 KAIC, 600V Max. TERMINAL DESCRIPTION Standard Starter - 5 KAIC, 600V Max. Wet Remote Input - Accepts wetted customer input. Input Combination Starter - 100 KAIC, 240V Max. voltage must be within 12 - 250 VAC/VDC (4.2mA Max.). 30 KAIC, 480V Max. V3 / V4 Sending voltage to the contact will send a run command to 10 KAIC, 600V Max. Installation & Operation Guide the starter when in Remote Mode. • Ambient Operating Temperature = -20°C to 60°C This manual is available for download at • Ambient Storage Temperature = -40°C to 85°C Shutdown Input - Accepts wetted customer input. Input www.franklin-controls.com voltage must be within 12 - 250 VAC/VDC (4.2mA Max.). DANGER V1 / V2 When the input is active, the contactor will open in all modes. START/STOP/REMOTE LED’s will flash indicating a • Ensure that all connections are properly torqued and enclosure is closed shutdown. prior to applying power to the device. Precautions • Ensure all mechanical equipment operated by the starter is clear for safe Status and Fault Relay Output - O1 - Fault Terminal: Con- To prevent injury and property damage, follow these instructions. operation in case of starter activation. nects to a relay contact that closes in a fault condition. Failure to adhere to installation/operation procedures and all • When in REMOTE mode, starter may be activated remotely by the O - Common: Common connection for the fault and status applicable codes may result in hazards as indicated by warning control system relays. -
Installation Instructions Rotary Pha Secon Ve Rters
I N S T A L L A T I O N I N S T R U C T I O N S R O T A R Y PHA S E C O N VE R T E R S Notice Before permanently installing this converter make sure it will operate your load! You may temporarily connect your converter through the cover opening and satisfy yourself that your converter is adequate to operate your equipment before removing any knockouts or making permanent connections which would prevent return or exchange of this device. Be sure to read all the instructions carefully before you attempt installation–we cannot be responsible for the failure of an incorrect installation. Important–To the installing Licensed Electrician 1. The generated phase (T3) is red in color. DO NOT connect the generated phase (T3) to any single-phase loads, lights, or magnetic starter holding coils. 2. DO NOT connect a single-phase supply line to T3 3. This is a Delta 3-phase system. High voltage to ground (neutral) from T3 is perfectly normal and will not affect the normal operation of 3-phase equipment. W arning: Disconnect power before servicing or connecting any equipment! Electric shock can injure or kill you. This equipment should be installed in accordance with local and National Electric Codes. 1. Connect your rotary converter(s) and 3-phase equipment according to the appropriate wiring diagram following. Charts are provided which list wire, transformer and fusing recommendations for converters and 3-phase motors. Be sure all equipment is properly grounded per NEC Article 250. -
Wiring Diagram Book
File 0140 L1 L2 L3 GND AC L1 L2 OFF A1 B1 START L1 13 21 ON 15 B2 START F F B2 M OL B1STOP B3STOP STOP 2 3 U U 1 15 22 1 2 14 460 V 230 V START H1 H3 H2 H4 X3 X2 H1 H3 H2 H4 Orange H Green Supply voltage 16 18 M LOAD Optional Connection 16 B3 L X1 M L2 X1115 V X2 Electrostatically 18 A2 AC Shielded Transformer 2 Levels 1 2 4 R Power 5 6 8 F F On F F Location U U U U Status 9 10 12 3 5 6 4 (N.O. or N.C.) 13 21 31 43 53 13 (–) 14 (+) X1A X2A Optional A1/+ 15 25 Z1 Z2 14 22 32 44 54 A1 B1 15 B2 B2 B1 B3 HAZARDOUS LOCATIONS NONHAZARDOUS LOCATIONS 15 CLASS I GROUPS A, B, C & D CLASS II GROUPS E, F & G CLASS III H FIBER OPTIC FIBER OPTIC Supply voltage 16 18 PUSH BUTTON, TRANSCEIVER 16 B3 L 16 1826 28 A2/– SELECTOR SWITCH, M LIMIT SWITCH, ETC. CLASS 9005 TYPE FT 18 A2 V 2 Levels s FIBER OPTIC CABLE FIBER OPTIC CABLE ELECTRICAL CONNECTIONS M 1CT T1 A1 L1 135 BOUNDARY SEAL TO BE IN L1 L2 L3 ACCORDANCE WITH ARTICLE 501-5 OF THE NATIONAL M T2 ELECTRICAL CODE L2 MOTOR A1 A2 A2 M 3CT T3 3 L3 CIRCUIT BREAKER OR DISCONNECT SWITCH L1 L2 L3 SOLID STATE T1 T2 T3 1 OVERLOAD RELAY TO 120 V SEPARATE CONTROL MOTOR STOP START OT* * OT is a switch that opens 2 T1 T2 T3 M when an overtemperature T1 T2 T3 M condition exists (Type MFO and MGO only) 246 Wiring Diagram Book TRADEMARKS QWIK-STOP® and ALHPA-PAK® are registered trademarks of Square D. -
Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)
Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition) 1. Which drawing type shows physical details as seen by the eye? 2. Which drawing is similar to a pictorial drawing but has circles or rectangles for components? 3. Which drawing type shows the circuitry necessary for operation but not the physical components or their location? 4. Which diagram shows the most direct path and logical sequence of operation? 5. What is necessary in an electrical circuit before current can flow? 6. What are the main parts of an electrical circuit? 7. What is the term used to describe a circuit where a person is required to initiate and action? 8. What is indicated when two wires cross with a dark black node on the point? 9. How is a start pushbutton indicated on a line diagram? 10. What are three actions that will stop the motor in Diagram 4-10 4th Edition (Diagram 2- 12 5th Edition) once it has started? 11. What type of contact is required on a float switch to maintain a water level in a tank? 12. What is the term used to describe an electrical device that converts electrical energy into linear mechanical force? 13. Which device is constructed similar to a solenoid but is designed to operate a set of contacts with the linear movement? 14. What is the difference between a Contactor and a Magnetic Starter? 15. What is the proper procedure when an overload condition occurs in a motor starter? 16. Which components are typically located inside a control panel? 17. -
Introduction Types of Motor Starters
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor. These electrical devices are also used for the purpose of stopping, reversing and protecting electric motors. The following are the two major components of a starter: 1. Contactor: The main function of the contactor is to control the electric current to the motor. A contactor can make or break power to the circuit. 2. Overload Relay: Overheating and drawing too much current can cause the motor to burn out and become practically useless. Overload relays prevent this from happening and protect the motor from any potential danger. A starter is an assembly of these two components, which allows it to turn on or off an electric motor or motor controlled electrical equipment. The starter also provides the necessary overload protection to the circuit. Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: 1. Manual Starters Manual starters are devices that are operated manually. These starters are extremely easy and straightforward to operate and do not require expert intervention. The starter includes a button (or rotary knob) which enables a user to turn the connected equipment on or off. The buttons feature mechanical linkages, which make the contacts open or close, starting or stopping the motor. The following features of a manual starter make it a preferred choice over other types: • These starters deliver a safe, as well as economical operation. -
Unified Facilities Criteria (Ufc) Interior Electrical Systems
UFC 3-520-01 June 10, 2002 UNIFIED FACILITIES CRITERIA (UFC) INTERIOR ELECTRICAL SYSTEMS U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING COMMAND CANCELLED AIR FORCE CIVIL ENGINEER SUPPORT AGENCY (Preparing Activity) APPROVED FOR PUBLIC RELEASE: DISTRIBUTION UNLIMITED UFC 3-520-01 June 10, 2002 UNIFIED FACILITIES CRITERIA (UFC) UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS) FORMAT STANDARD Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. Record of Changes (changes are indicated by \1\ ... /1/) Change No. Date Location CANCELLED UFC 3-520-01 June 10, 2002 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD(AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status of forces Agreements (SOFA), Host Nation Funded Construction Agreements (HNFA), and in some instances, Bilateral Infrastructure Agreements (BIA.) Therefore, the acquisition team must ensure compliance with the more stringent of the UFC, the SOFA, the HNFA, and the BIA, as applicable. UFC are living documents and will be periodically reviewed, updated, and made available to users as part of the Services’ responsibility for providing technical criteria for military construction. Headquarters, U.S. Army Corps of Engineers (HQUSACE), Naval Facilities Engineering Command (NAVFAC), and Air Force Civil Engineer Support Agency (AFCESA) are responsible for administration of the UFC system. -
Switches for Industrial Applications
Switches For Industrial Applications ELECTROSWITCH The Best Switches… Backed by the industry’s most knowledgeable and responsive engineering and customer service professionals... Any way you want them... Delivered when you need them. ELECTROSWITCH NEVER A DOUBT TABLE OF CONTENTS The Advantage Is Yours 2 Detent-Action Rotary Switches 10 Snap-Action Rotary Switches 20 Cam-Action Rotary Switches 30 Tap Switches 37 Knife Switches 42 Construction Details 47 Handles 50 Nameplates 52 Accessories 53 Testing & Life Expectancy 54 THE ADVANTAGE IS YOURS hen you choose Electroswitch products the advantage is always yours... For over 50 years Electroswitch products Whave been specified for use in the most demanding, most critical industrial applications by most major equipment manufacturers in the United States. They know that when you specify Electroswitch products you have chosen the most dependable, most reliable, and most proven products available in the world today. With Electroswitch there is Never a Doubt. Electroswitch also offers the widest variety of industrial switches available today. There are virtually millions of different potential configurations to precisely meet applications. We offer a choice of detent-, snap- and cam-action switches, as well as tap switches and knife switches to enhance your application. The Advantage is Always Yours when you work with Electroswitch. THE ADVANTAGE IS YOURS You Get The Greatest Selection. hen we say we have a full line of products, we mean exactly that. Whatever your • Detent Switches W application, you will either find a standard switch to precisely match it or we will design and test a • Snap Switches special switch to meet your needs. -
Specification Sheet Automatic Digital Modulating Humidifier Control
SPECIFICATION SHEET AUTOMATIC DIGITAL MODULATING HUMIDIFIER CONTROL MODEL 63 PACKAGE MODEL 5558 PACKAGE Includes Modulating Humidistat, Duct Sensor, Blower Activation Includes Modulating Humidistat and Outdoor Temperature Sensor Relay and Outdoor Temperature Sensor The Model 5558 Automatic Digital Modulating Control package The Model 63 Automatic Digital Modulating Control (ADMC) is the recommended humidistat for the Aprilaire modulating package is the recommended humidistat for the Aprilaire steam fan pack ductless humidifier, Model 866. modulating steam humidifier, Model 801. WALL MOUNTED CONTROL FEATURES OUTDOOR TEMPERATURE SENSOR • Microcomputer based design with proportional algorithm – When used with the wall mounted humidistat the humidity set providing exceptional accuracy point is automatically readjusted based on the difference • Digital display – large LCD with backlight with humidification between the room temperature and the outside temperature to and dehumidification indicators prevent window condensation. • Outputs – controls humidification and dehumidification equipment • Output signals – on/off and/or proportional outputs provides INCLUDED IN MODEL 63 PACKAGE ONLY greater flexibility • Modulating output signal – provides a 0 to 10Vdc or 2-10Vdc proportional control signal to the humidifier. DUCT HUMIDITY SENSOR FEATURES • Proportional Duct Sensor can be used as the primary • Integrated sensor or remote duct sensing for better application measurement of the relative humidity in the duct instead of the flexibility room and responds to the needs of wall mounted humidistat • Programable proportional band to increase or decrease the • When not used as the controlling sensor, the Duct Sensor sensitivity of the humidifier control can be use as a proportional high limit override – provides • Humidity set point – adjustable from 0 to 100% relative humidity a feedback to the wall mounted humidistat to prevent • Humidity setpoint reset based on outdoor temp. -
MP Series Modular Photoelectric Sensors
Photoelectric Sensors MP Series Modular Photoelectric Sensors Photoelectric • Harsh Duty • Modular design - Exchangeable rotatable heads - Limit switch and mini style plug-in bases - Screw terminal, preleaded, and connector version receptacles MP Series Modular • Withstands 1200 psi washdown, IP69K • 6 A SPDT and 5 A DPDT relay MP Series modular sensors enable users to customize a sensing solution for almost any models application. For this reason, the components of • Multifunction timer/logic cards this series are sold separately. Refer to pages available 594-595 for instruction on how to assemble an MP Series sensor. • DC, AC, AC/DC models Diffuse Retro-Reflective Mode Mode Sensing Ranges: 300 mm, 450 mm, 760 mm, Features: 900 mm, 1.3 m, 1.8 m, 3 m • Polarization filter to detect shiny objects Outputs: Dependent on base selected Sensing Ranges: 4.5 m, 6 m, 9 m Outputs: Dependent on base selected Thru-Beam Fiber Optic Mode Mode Sensing Ranges: 36 m, 60 m Sensing Ranges: Dependent on fibers selected Outputs: Dependent on base selected Outputs: Dependent on base selected See page 610-620 for MP Series sensing charateristics, wiring, dimensions and accessories. Subject to modifications without notice Copyright Pepperl+Fuchs Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776-4411 Singapore: +65 6779 9091 www.pepperl-fuchs.com [email protected] [email protected] [email protected] 593 BUILD AN SELECT MP SENSOR 1. A HEAD 1 2 3 Head Plug-in/DPDT Relay Base SPDT Relay Base Mini Style Base Receptacle -
VAPOR-LOGIC®3 Microprocessor-Based Humidifier Control System Installation and Operation Manual
Read and save these instructions! VAPOR-LOGIC®3 Microprocessor-based humidifier control system Installation and operation manual VL3-IOM-0200-METRIC.pdf 1 11/19/2009 9:19:43 AM PLEASE: read this manual! Visit our web site: www.dristeem.com This manual will guide you through installation, operation and maintenance procedures for your new For information about other DRI-STEEM products, visit ® VAPOR-LOGIC 3 microprocessor-based humidifier our web site, or contact us using the information listed control system. Proper installation and operating below. practices will ensure years of trouble-free service. For information about your humidifier tank or dispersion unit, please see the manuals for those specific products. For technical support, contact your DRI-STEEM distributor or call +44 1280 850122 or fax +44 1280 850124. If you have questions, first review Pages 54-70, which describe typical problems and solutions, and also list information you will need to give us if you call. Corporate headquarters European office 14949 Technology Drive • Eden Prairie, MN 55344 Bell Place, Bell Lane • Syresham, Brackley • NNN13 5HP, UK 952-949-2415 • 800-328-4447 • 952-229-3200 (fax) +44 1280 850122 • +44 1280 850124 (fax) [email protected] (e-mail) [email protected] (e-mail) VL3-IOM-0200-METRIC.pdf 2 11/19/2009 9:19:51 AM ® VAPOR-LOGIC3 table of contents. Product overview Operation Features summary ..................................................1-2 Start-up checklist ...............................................24-25 Circuit board diagram ............................................... 3 Keypad/display overview........................................ 26 Main control board connections .............................4-6 Menu structure ........................................................ 27 Expansion board connections ................................... 7 “Set Up” menu information.................................... -
Humidifier Application Guide
Humidifier Application Guide Aprilaire® humidifiers can be installed on many different types of HVAC equipment and controlled to provide optimum humidity levels for each application. This Application Guide is to assist installers in selecting which Aprilaire humidifier is appropriate for a particular application and how to configure the controls to deliver optimum humidity. To use this guide, select the application (type of HVAC equipment) and humidifier model then turn to the appropriate reference page. The reference pages will give you guidelines for installation, when and how to use blower activation, and how to connect third party controls. Plenum Recommended Page Application Temperature (°F) Model Series Control Automatic Manual Gas or Electric 65, 4655 with model 3 120-140 400, 500, 600,700, 800 60, 62, 8910, 8620 Heat 50 or 4851 65, 4655 with model 6 Boiler Air Handling Unit 120-140 400, 500, 600,700, 800 60, 62, 8910, 8620 with accessible 50 or 4851 supply and return 65, 4655 with model 9 Heat Pump 90-100 400, 500, 600,700, 800 60, 62, 8910, 8620 plenums 50 or 4851 800 and 800 with 850 65, 4655 with 4851 12 Air Conditioning Below 90 62, 8910, 8620 Fan Pack and 8024 No forced air 15 800 with 850 Fan Pack 8910, 8620 65, 4655 system Air Handling Unit 65, 4655 with model 16 700, 800 60, 62, 8910, 8620 with no return duct 50 or 4851 Alternate 19 configurations and 400, 500, 600, 700, 800 60, 62 wiring diagrams ITEMS NOT FURNISHED TOOLS NEEDED Mounting screws (sheet metal screws) 1/2” and 7/16” combination wrench Water supply line (1/4” OD copper) 1/8” by 2” flathead screw driver 18AWG low voltage wire Tin snips Bypass duct (bypass units only) Wire stripper Model 50 or 4851 relays (to be used with manual humidistats only) *See Installation Instructions for more information Note: • Do not install where freezing temperatures can occur.