BEST MANAGEMENT PRACTICES Wildfire Prevention

Total Page:16

File Type:pdf, Size:1020Kb

BEST MANAGEMENT PRACTICES Wildfire Prevention BEST MANAGEMENT PRACTICES Wildfire Prevention January 2008 2007-0022 2100, 350 – 7th Ave. S.W. 403, 235 Water Street Calgary, Alberta St. John’s, Newfoundland Canada T2P 3N9 Canada A1C 1B6 Tel (403) 267-1100 Tel (709) 724-4200 Fax (403) 261-4622 Fax (709) 724-4225 Email: [email protected] Website: www.capp.ca The Canadian Association of Petroleum Producers (CAPP) represents 140 companies that explore for, develop and produce natural gas, natural gas liquids, crude oil, oil sands, and elemental sulphur throughout Canada. CAPP member companies produce more than 97 per cent of Canada’s natural gas and crude oil. CAPP also has 125 associate members that provide a wide range of services that support the upstream crude oil and natural gas industry. Together, these members and associate members are an important part of a $65-billion-a-year national industry that affects the livelihoods of more than half a million Canadians. CAPP engaged QSI Quality Service Investigations Inc. (QSI) to develop Best Management Practices for Wildfire Prevention for the upstream oil and gas industry. QSI assembled a team of experts with numerous years of experience and training in wildland fire management. The Team members are: Bill Bereska, Dennis Quintilio, Murray Heinrich and Kelly O’Shea. Throughout the development of this document, QSI worked with members of the Industrial Wildfire Prevention Working Group who reviewed the document and provided comments and suggestions. CAPP wishes to acknowledge the interest and support from these members and from other stakeholders whose joint efforts have helped make this a more useful document for all. Review by December 2012 Disclaimer This publication was prepared for the Canadian Association of Petroleum Producers (CAPP) by QSI Quality Service Investigations Inc. (QSI). While it is believed that the information contained herein is reliable under the conditions and subject to the limitations set out, CAPP and QSI do not guarantee its accuracy. The use of this report or any information contained will be at the user’s sole risk, regardless of any fault or negligence of QSI, CAPP, or its co- funders. 2100, 350 – 7th Ave. S.W. 403, 235 Water Street Calgary, Alberta St. John’s, Newfoundland Canada T2P 3N9 Canada A1C 1B6 Tel (403) 267-1100 Tel (709) 724-4200 Fax (403) 261-4622 Fax (709) 724-4225 Email: [email protected] Website: www.capp.ca Contents Project Scope .......................................................................................................................1 Overview..................................................................................................................1 1 Introduction..............................................................................................................3 1.1 Context.........................................................................................................3 1.2 Case Studies of Selected Industry-Related Fires .........................................3 1.3 Forest Fire Prevention Overview for the Oil and Gas Industry...................9 1.4 Historical Industry-Related Fires in Alberta..............................................11 1.4.1 Historical Oil and Gas Industry Wildfires .....................................12 1.4.2 Historical Forest Industry Wildfires ..............................................14 1.4.3 Historical Railroad Wildfires.........................................................15 1.4.4 Historical Power Line Wildfires ....................................................16 1.5 Timing of Industry Related Wildfires........................................................17 2 Regulatory Aspects................................................................................................18 2.1 Legislation, Codes, Directives, Guidelines And Agreements....................18 2.1.1 Forest and Prairie Protection Act and Regulations........................18 2.1.2 Occupational Health and Safety Code 2006 ..................................19 2.1.3 EUB Directive 060 Upstream Petroleum Industry Flaring, Incinerating, and Venting....................................................................................20 2.1.4 EUB Directive 071 Emergency Preparedness and Response Requirements for the Upstream Petroleum Industry.............................................20 2.1.5 Alberta Building Code ...................................................................21 2.1.6 Alberta Fire Code...........................................................................21 2.1.7 Municipal Government Act ...........................................................21 2.1.8 Other Acts and Regulations ...........................................................21 2.1.9 Fire Control Plans and Agreements ...............................................22 2.1.10 Guidelines and Directives..............................................................22 3 Integrated Land Management ................................................................................23 4 Seasonal and Daily Fire Danger ............................................................................24 5 Emergency Response Planning..............................................................................26 5.1 Industrial Wildfire Control and Prevention Plan (IWCPP) .......................27 5.2 Incident Command System........................................................................28 5.3 Personnel Safety.........................................................................................28 5.4 Training......................................................................................................28 5.5 Municipal Emergency Plan........................................................................29 5.6 Infrastructure Protection............................................................................29 5.7 Resources ...................................................................................................29 6 Communications ....................................................................................................30 January 2008 Best Management Practices for Wild Fire Prevention i 6.1 Internal Communications...........................................................................30 6.2 External Communications..........................................................................30 6.3 Delivery and Format ..................................................................................31 7 Best Management Practices For Fire Prevention...................................................33 7.1 Brush Burning............................................................................................33 7.1.1 Issue ...............................................................................................33 7.1.2 Background....................................................................................33 7.1.3 Best Management Practices ...........................................................33 7.2 Flaring........................................................................................................35 7.2.1 Issue ...............................................................................................35 7.2.2 Background....................................................................................35 7.2.3 Best Management Practices ...........................................................36 7.3 All Terrain Vehicles...................................................................................38 7.3.1 Issue ...............................................................................................38 7.3.2 Background....................................................................................38 7.3.3 Best Management Practices ...........................................................38 7.4 Heavy Equipment.......................................................................................40 7.4.1 Issue ...............................................................................................40 7.4.2 Background....................................................................................40 7.4.3 Best Management Practices ...........................................................40 7.5 Light Equipment ........................................................................................41 7.5.1 Issue ...............................................................................................41 7.5.2 Background....................................................................................41 7.5.3 Best Management Practices ...........................................................41 7.6 Welding......................................................................................................42 7.6.1 Issue ...............................................................................................42 7.6.2 Background....................................................................................42 7.6.3 Best Management Practices ...........................................................42 7.7 Using Fire Safely .......................................................................................43 7.7.1 Issue ...............................................................................................43 7.7.2 Background....................................................................................43 7.7.3 Best Management Practices ...........................................................44 a. Smoking .....................................................................................44
Recommended publications
  • Preliminary Report: Stream Crossings and Arctic Grayling Conservation in the Athabasca River Basin
    Preliminary Report: Stream Crossings and Arctic Grayling Conservation in the Athabasca River Basin CONSERVATION REPORT SERIES The Alberta Conservation Association is a Delegated Administrative Organization under Alberta’s Wildlife Act. CONSERVATION REPORT SERIES 25% Post Consumer Fibre When separated, both the binding and paper in this document are recyclable Preliminary Report: Stream Crossings and Arctic Grayling Conservation in the Athabasca River Basin Laura MacPherson1 and Troy Furukawa2 1University of Alberta, Department of Renewable Resources 751 General Services Building Edmonton, Alberta T6G 2H1 2Alberta Conservation Association #101, 9 Chippewa Rd Sherwood Park, Alberta T8A 6J7 Report Editors PETER AKU GLENDA SAMUELSON Alberta Conservation Association 2123 Crocus Road NW #101, 9 Chippewa Rd Calgary AB T2L 0Z7 Sherwood Park AB T8A 6J7 Conservation Report Series Type Preliminary Report Disclaimer: This document is an independent report prepared by the Alberta Conservation Association. The authors are solely responsible for the interpretations of data and statements made within this report. Reproduction and Availability: This report and its contents may be reproduced in whole, or in part, provided that this title page is included with such reproduction and/or appropriate acknowledgements are provided to the authors and sponsors of this project. Suggested Citation: MacPherson, L., and T. Furukawa. 2010. Preliminary report: Stream crossings and Arctic Grayling conservation in the Athabasca River Basin. Produced by the Alberta Conservation
    [Show full text]
  • Eddyline Northwest Voyageurs Canoe and Kayak Club
    The SEPTEMBER 2006 EDDYLINE NORTHWEST VOYAGEURS CANOE AND KAYAK CLUB Since 1964 Since 1964 Box 1341, Edmonton, AB T5J 2N2 Internet Address: www.nwvoyageurs.com Upcoming Events Sept 27 (Wed) General Meeting 7:30 pm Lions Seniors Centre, 11113 -113 St. TBA Oct 3 (Tues) Executive Meeting—Moved to Oct 10 Oct 7 (Sat) Trip Schedule Change - North Saskatchewan River from Genesse Bridge to Golden Spike Change from Oct 8 to Oct 7— A nice fall paddle of about 4 or 5 hours—perhaps a weiner roast to end the season. This change in trip date was requested so that families can enjoy Thanksgiving Sunday & Monday together—Contact Melvyn Kadyk 484-3563 Oct 10 (Tues) Executive Meeting 7:30 pm Lions Seniors Centre, 11113 -113 St. The club executive meets to discuss club business. Members are welcome to attend. Nov 22 (Wed) Photo Contest — General Meeting 7:30 pm Lions Seniors Centre, 11113 -113 St. Enter your photos from this year. Members are welcome to attend. January to Beginner Kayak Lessons — Starting January 2007 April 2007 Lessons start January 5, 2007 More information to come NWV EXECUTIVE 2006 President Rick Fetterly 438-1296 fetterly(a)shaw.ca * Vice President Doug Knight 435-2348 dknight(a)telusplanet.net Treasurer Norma Ouellette 444-0263 normao(a)nait.ab.ca Secretary Josephine Petesky 474-2751 * Membership Steve Budziszyn 461-3292 * Newsletter Don Litven 476-7006 don_litven(a)hotmail.com Website Ben Coxworth 438-4062 coxworth(a)shaw.ca * Publicity/Archives Alan Stewart 487-0607 * Trip Coordinator Melvyn Kadyk 484-3563 Canoe Coordinator Doug
    [Show full text]
  • Alberta Watersmart
    Alberta Innovates A Roadmap for Sustainable Water Management in the Athabasca River Basin Submitted by: Dr. P. Kim Sturgess, C.M., P.Eng., FCAE CEO WaterSMART Solutions Ltd. 605, 839 5th Ave SW Calgary, Alberta T2P 3C8 [email protected] Submitted to: Dallas Johnson Director, Integrated Land Management Alberta Innovates 1800 Phipps McKinnon Building 10020 – 101A Avenue Edmonton, Alberta T5J 3G2 [email protected] Submitted on: September 28, 2018 The Sustainable Water Management in the Athabasca River Basin Initiative was enabled through core funding provided by Alberta Innovates and matching funds contributed by the Alberta Energy Regulator, Alberta Environment and Parks, ATCO, Repsol Oil and Gas, Suncor Energy, and Westmoreland Coal Company. This report is available and may be freely downloaded from http://albertawatersmart.com/featured- projects/collaborative-watershed-management.html Alberta Innovates (Al) and Her Majesty the Queen in right of Alberta make no warranty, express or implied, nor assume any legal liability or responsibility for the accuracy, completeness, or usefulness of any information contained in this publication, nor that use thereof infringe on privately owned rights. The views and opinions of the author expressed herein do not necessarily reflect those of AI or Her Majesty the Queen in right of Alberta. The directors, officers, employees, agents and consultants of AI and the Government of Alberta are exempted, excluded and absolved from all liability for damage or injury, howsoever caused, to any person in connection with or arising out of the use by that person for any purpose of this publication or its contents. Suggested citation for this report: WaterSMART Solutions Ltd.
    [Show full text]
  • Fire Dynamics and Forensic Analysis of Liquid Fuel Fires
    The author(s) shown below used Federal funds provided by the U.S. Department of Justice and prepared the following final report: Document Title: Fire Dynamics and Forensic Analysis of Liquid Fuel Fires Author: Christopher L. Mealy, Matthew E. Benfer, Daniel T. Gottuk Document No.: 238704 Date Received: May 2012 Award Number: 2008-DN-BX-K168 This report has not been published by the U.S. Department of Justice. To provide better customer service, NCJRS has made this Federally- funded grant final report available electronically in addition to traditional paper copies. Opinions or points of view expressed are those of the author(s) and do not necessarily reflect the official position or policies of the U.S. Department of Justice. This document is a research report submitted to the U.S. Department of Justice. This report has not been published by the Department. Opinions or points of view expressed are those of the author(s) and do not necessarily reflect the official position or policies of the U.S. Department of Justice. FIRE DYNAMICS AND FORENSIC ANALYSIS OF LIQUID FUEL FIRES Final Report Grant No. 2008-DN-BX-K168 Prepared by: Christopher L. Mealy, Matthew E. Benfer, and Daniel T. Gottuk Hughes Associates, Inc. 3610 Commerce Drive, Suite 817 Baltimore, MD 21227 Ph. 410-737-8677 FAX 410-737-8688 February 18, 2011 This document is a research report submitted to the U.S. Department of Justice. This report has not been published by the Department. Opinions or points of view expressed are those of the author(s) and do not necessarily reflect the official position or policies of the U.S.
    [Show full text]
  • What Properties Matter in Fire-Fighting Foams?
    WHITEPAPER WHAT PROPERTIES MATTER IN FIRE-FIGHTING FOAMS? National Research Institute of Fire and Disaster 2nd NRIFD Symposium - Conference Proceedings Tokyo, 2002 WHAT PROPERTIES MATTER IN FIRE-FIGHTING FOAMS? B.Z. Dlugogorski1, E.M. Kennedy1, T.H. Schaefer2 and J.A. Vitali3 SUMMARY The perfluoroalkyl sulphonate surfactants used in film-forming fire-fighting foams and a range of other applications have been classified as so-called persistent organic pollutants (POPs). The US EPA has recently introduced restrictions which effectively stop further production of perfluoroalkyl sulphonate-based surfactants, such as perfluorooctyl sulphonate (PFOS) and its salts, in the USA. The US EPA has also commissioned a hazard assessment study of perfluorooctanoic acid (PFOA) and its salts, in which the initial findings appear to identify issues that could lead to the potential phase-out of the PFOA surfactants. Thus it seems inevitable that in the foreseeable future the use of fluorinated surfactants will be substantially regulated for all but a small number of critical applications. As a consequence of their highly dispersive use, it is likely that fluorinated surfactants included in fire-fighting foam formulations will be scrutinised closely by environmental authorities around the world. This paper reviews the existing protocols for testing the extinguishment of liquid-fuel fires with aqueous foams. The requirements and objectives of the testing protocols are critically appraised. Subsequently, the paper explains the fire suppression behaviour of foams in terms of the fundamental properties of these materials including their bulk viscosity, yield stress, drainage rate and interbubble gas diffusion (coarsening). The limitation of the spreading coefficient, as presently defined, is also explored, and the need for dynamic measurements of surface tension and surface viscosity is stressed, together with a need to gain a better understanding of the interfacial forces between a hydrocarbon fuel and a spreading foam.
    [Show full text]
  • Northern River Basins Study
    Northern River Basins Study NORTHERN RIVER BASINS STUDY PROJECT REPORT NO. 133 SEDIMENT DYNAMICS AND IMPLICATIONS FOR SEDIMENT-ASSOCIATED CONTAMINANTS IN THE PEACE, ATHABASCA AND Prepared for the Northern River Basins Study under Project 5315-E1 by Michael A. Carson Consultant in Environmental Data Interpretation and Henry R. Hudson Ecological Research Division, Environment Canada NORTHERN RIVER BASINS STUDY PROJECT REPORT NO. 133 SEDIMENT DYNAMICS AND IMPLICATIONS FOR SEDIMENT-ASSOCIATED CONTAMINANTS IN THE PEACE, ATHABASCA AND SLAVE RIVER BASINS Published by the Northern River Basins Study Edmonton, Alberta March, 1997 CANADIAN CATALOGUING IN PUBLICATION DATA Carson, Michael A. Sediment dynamics and implications for sediment associated contaminants in the Peace, Athabasca and Slave River Basins (Northern River Basins Study project report, ISSN 1192-3571 ; no. 133) Includes bibliographical references. ISBN 0-662-24768-X Cat. no. R71-49/3-133E 1. River sediments -- Environmental aspects -- Alberta - Athabasca River. 2. River sediments - Environmental aspects - Peace River (B.C. and Alta.) 3. River sediments -- Environmental aspects - Slave River (Alta, and N.W.T.) 4. Sedimentation and deposition - Environmental aspects -- Alberta -- Athabasca River. 5. Sedimentation and deposition - Environmental aspects - Peace River (B.C. and Alta.) 6. Sedimentation and deposition - Environmental aspects - Slave River (Alta, and N.W.T.) I. Hudson, H.R. (Henry Roland), 1951- II. Northern River Basins Study (Canada) III. Title. IV. Series. TD387.A43C37 1997 553.7'8'0971232 C96-980263-3 Copyright© 1997 by the Northern River Basins Study. All rights reserved. Permission is granted to reproduce all or any portion of this publication provided the reproduction includes a proper acknowledgement of the Study and a proper credit to the authors.
    [Show full text]
  • Valero Refinery Propane Fire
    U.S. CHEMICAL S AFETY AND H AZARD INVESTIGATION B OARD INVESTIGATION REPORT LPG FIRE AT VALERO – MCKEE REFINERY (Four Injured, Total Refinery Evacuation, and Extended Shutdown) Photo: Associated Press VALERO ENERGY CORPORATION SUNRAY, TEXAS FEBRUARY 16, 2007 KEY ISSUES: • FREEZE PROTECTION OF DEAD-LEGS • EMERGENCY ISOLATION OF EQUIPMENT • FIREPROOFING OF SUPPORT STEEL • FIRE PROTECTION FOR HIGH PRESSURE LPG SERVICE • CHLORINE RELEASE REPORT NO. 2007-05-I-TX JULY 2008 Valero - Sunray July 2008 Contents EXECUTIVE SUMMARY ..........................................................................................................................6 1.0 INTRODUCTION .........................................................................................................................10 1.1 Background.......................................................................................................................10 1.2 Investigative Process.........................................................................................................10 2.0 VALERO ENERGY CORPORATION.........................................................................................11 2.1 Company History..............................................................................................................11 2.2 McKee Refinery................................................................................................................11 2.3 Propane Deasphalting (PDA) Unit....................................................................................12
    [Show full text]
  • Supplement of High-Resolution Meteorological Forcing Data for Hydrological Modelling and Climate Change Impact Analysis in the Mackenzie River Basin
    Supplement of Earth Syst. Sci. Data, 12, 629–645, 2020 https://doi.org/10.5194/essd-12-629-2020-supplement © Author(s) 2020. This work is distributed under the Creative Commons Attribution 4.0 License. Supplement of High-resolution meteorological forcing data for hydrological modelling and climate change impact analysis in the Mackenzie River Basin Zilefac Elvis Asong et al. Correspondence to: Zilefac Elvis Asong ([email protected]) The copyright of individual parts of the supplement might differ from the CC BY 4.0 License. Table S1: List of observation stations located over the Mackenzie River Basin. The start and end dates for data availability as well the percentage of missing data during the period 2005 – 2016 for climate variables are indicated. The climate variables are P=Precipitation; T=Air Temperature; RH=Relative Humidity; wind=Wind Speed; and ps=Surface Pressure. Coordinates Record % Complete Station Name Prov. ID Lat Long Elev. Start End T P RH ps wind TULITA A NT 1650 64.91 -125.57 100.30 1903 2014 32.9 44.2 0.0 0.0 0.0 CAMPSIE AB 2490 54.13 -114.68 670.60 1910 2013 72.3 72.3 0.0 0.0 0.0 BEAVERLODGE CDA AB 2658 55.20 -119.40 744.90 1913 2007 5.1 4.1 0.0 0.0 0.0 ENTRANCE AB 2511 53.37 -117.70 990.60 1917 2006 6.2 11.0 0.0 0.0 0.0 FORT RESOLUTION A NT 1654 61.18 -113.69 160.30 1930 2014 34.3 42.0 0.0 0.0 0.0 FORT NELSON A BC 1455 58.84 -122.60 381.90 1937 2012 65.5 65.5 63.9 64.2 64.4 WATSON LAKE A YT 1615 60.12 -128.82 687.35 1938 2014 81.9 81.9 80.0 82.5 82.5 CARROT CREEK LO AB 2492 53.45 -115.87 1043.90 1939 2011 11.3
    [Show full text]
  • Bsria - B Northern Riverbasinsstudy
    Canada /dlbsria - B Northern RiverBasinsStudy J NORTHERN RIVER BASINS STUDY PROJECT REPORT NO. 32 A GENERAL FISH AND RIVERINE HABITAT INVENTORY, ATHABASCA RIVER APRIL TO MAY, 1992 QL 626. 5 . A42 R109 1994 QL/626.5/. A42/R109/1'3'94 A general fis h and riverine R L & L Environmental Date Due Y X O I M v f Prepared for the Northern River Basins Study under Project 3117-B1 by R.L. & L. Environmental Services Ltd. Community Contributors: Curtiss Girard, Fort Chipewyan NORTHERN RIVER BASINS STUDY PROJECT REPORT NO. 32 A GENERAL FISH AND RIVERINE HABITAT INVENTORY, ATHABASCA RIVER APRIL TO MAY, 1992 ATHABASCA UNIVERSITY Published by the Northern River Basins Study Edmonton, Alberta MAR 3 0 1S95 April, 1994 LIBRARY CANADIAN CATALOGUING IN PUBLICATION DATA Main entry under title: A General fish and riverine habitat inventory, Athabasca River, April to May, 1992 (Northern River Basins Study project report, ISSN 1192-3571 ; no. 32) Includes bibliographical references. ISBN 0-562-22040-4 Cat. no. R71-49/3-32E 1. Fishes — Alberta — Athabasca River — Habitat — Environmental aspects. 2. Fish populations — Alberta — Athabasca River. I. R.L. & L. Environmental Services. II. Northern River Basins Study (Canada) III. Series. QL625.5A42G36 1994 597.09712 C94-980106-2 Copyright (c) 1994 by the Northern River Basins Study. All rights reserved. Permission is granted to reproduce all or any portion of this publication provided the reproduction includes a proper acknowledgement of the Study and a proper credit to the authors. The reproduction must be presented within its proper context and must not be used for profit.
    [Show full text]
  • Storage Tank Fires: Is Your Department Prepared? by CRAIG H
    Continuing Education Course Storage Tank Fires: Is Your Department Prepared? BY CRAIG H. SHELLEY TRAINING THE FIRE SERVICE FOR 134 YEARS To earn continuing education credits you must successfully complete the course examination. The cost for this CE exam is $25.00. For group rates, call (973) 251-5055 storage tank Fires: Is Your Department Prepared? Educational Objectives On completion of this course, students will: ● Describe the different types of petroleum storage tanks ● Describe the importance of pre-incident planning ● List the typical tank fire types ● Describe proper response/extinguishment techniques B Y CRAIG H. SHELLEY 1 verY sIx months or so I reaD In eIther a news- (1) A storage paper clipping or trade journal about a petroleum tank full product storage tank fire occurring in the United states surface fire at E a petroleum or internationally. these fires have occurred on thew est Coast, storage facil- the east Coast, and cities in between. the most spectacular fire ity. (Photos occurring in past years was the 2005 hertfordshire oil storage courtesy of terminal Fire (Buncefield oil Depot) in england. most of the Williams Fire fires I have read about that involve petroleum product storage & Hazard Control.) tanks contain a common element that municipal firefight- ers generally overlook: municipal or volunteer firefighters either fought the fire or supported the firefight.a lthough we train daily on our bread-and-butter operations and terrorist of full surface tank fires require a large amount of commit- incident response techniques, we generally neglect training ment in human logistics and equipment resources. Because on industrial hazards within our districts.
    [Show full text]
  • Tank Fires Review of fi Re Incidents 1951–2003
    Henry Persson, Anders Lönnermark Tank Fires Review of fi re incidents 1951–2003 BRANDFORSK Project 513-021 SP Swedish National Testing and Research Institute SP Swedish National Testing The Orion Tank Fire in 2001, world record in tank fi re fi ghting. Photo courtesy of Industrial Fire World SP Fire Technology SP REPORT 2004:14 Henry Persson, Anders Lönnermark Tank Fires Review of fi re incidents 1951–2003 BRANDFORSK Project 513-021 2 Abstract A literature review has been conducted to gather information related to the extinguishment of actual tank fires and relevant large-scale fire extinguishing tests. The aim was to search for data that could be used for validation of foam spread models. In total, 480 tank fire incidents have been identified worldwide since the 1950s and the information collected has been compiled into a database. A list of the incidents with some data is provided in this report. Out of the 480 fire incidents, only about 30 fires have provided relevant information for model validation. A more detailed summary of the existing data from these fires is also provided in this report. Key words: Tank fires, foam extinguishment, large-scale tests, literature review SP Sveriges Provnings- och SP Swedish National Testing and Forskningsinstitut Research Institute SP Rapport 2004:14 SP Report 2004:14 ISBN 91-7848-987-3 ISSN 0284-5172 Borås 2004 Postal address: Box 857, SE-501 15 BORÅS, Sweden Telephone: +46 33 16 50 00 Telefax: +46 33 13 55 02 E-mail: [email protected] http://www.sp.se 3 Contents Abstract 2 Contents 3 Preface 4 Summary 5
    [Show full text]
  • Fitness-For-Duty Assessments of Industrial Firefighters: Guidance for Occupational Medicine Physicians
    ACOEM GUIDANCE STATEMENT Fitness-for-Duty Assessments of Industrial Firefighters: Guidance for Occupational Medicine Physicians Faiyaz A. Bhojani, MD, MPH, DrPH, Luis A. Castillejo-Picco, MD, MS, PhD, David Cathcart, DO, MPH, Edward A. Emmett, MD, MS, Stephen Frangos, MD, MPH, P. Mark Glencross, MD, MPH, Chris J. Herman, CFPS, Kevin O’Shea, MD, MPH, Paul Rountree, MD, and David E. Turner, MD, PhD, MPH, MBA, ACOEM Task Force on Fitness-for-Duty Assessments for Industrial Firefighters Industrial firefighters share many characteristics industries to develop fitness-for-duty guid- The questionnaire was reviewed by with municipal firefighters; however, employers ance for industrial firefighters and address the University of Pennsylvania Institutional frequently have not addressed or characterized the the lack of standards and guidance specific Review Board (IRB), which concluded the unique job duties, hazards, and specific physical/ to this population. This lack of a standard- project did not meet the criteria to be mental demands associated with industrial fire- ized approach could result in firefighters considered human research and was thus fighting. In addition, gaps exist in the medical being improperly assessed for their capa- exempt from further IRB oversight. The literature with regard to industrial firefighter dem- bility to safely perform industrial firefight- Task Force engaged ORCHSE Strategies, ographics, behavioral risk factors, and chronic ing duties and puts the firefighter, his/her LLC, a health, safety, and environmental diseases. Finally, the proper methodologies for coworkers, the workplace, and the commu- control network that sponsors a cross- fitness-for-duty assessment of employees acting nity at risk. This increased risk has the industry forum for purposes of benchmark- in this capacity are lacking.
    [Show full text]